IMEDIPLUS DS101 Electronic stethoscope User Manual Electronic Stethoscope Omni Steth

IMEDIPLUS INC. Electronic stethoscope Electronic Stethoscope Omni Steth

Contents

Electronic Stethoscope Omni-Steth User Manual

IMEDIPLUS INC. Special Submission Electronic Stethoscope DS101 Section 13 Document Title:ġElectronic Stethoscope DS101 User Manual File Name:ġ003_Electronic Stethoscope DS101 User Manual
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 2 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ Model name: DS101  Feature Auscultation for heart, Anterior/Posterior chest, neck, bowel, limbs arteries, veins and internal organs. Heart rate detection. Real time recording and playing of auscultation sounds. Recording multiple sounds in one patient and up to 160 10-second auscultation sound tracks. Clear acoustic performance. With auscultation sound amplify ability to 27dB and 10 volume level adjustable. Ergonomic Design. Easy to use. Rx only
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 3 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġContent 1.  Introduction ................................................................................................. 4 2.  Safety Information ....................................................................................... 4 2.1  Symbol Definitions .................................................................................. 5 2.2  Important Safety Information .................................................................. 6 3.  Product Description .................................................................................... 8 4.  Intended Use ................................................................................................ 9 5.  Operator Profile ........................................................................................... 9 6.  Patient Privacy ............................................................................................. 9 7.  Instructions for Use ................................................................................... 10 7.1  Stethoscope Interface ........................................................................... 10 7.2  Replacing Battery .................................................................................. 10 7.3  Removing and applying the eartube. ................................................... 11 7.4  Removing and applying the ear-tip. ..................................................... 12 7.5  Adjust Headset for Comfort .................................................................. 13 7.6  Replacing the chestpiece ...................................................................... 14 7.7  Replacing the disposable diaphragm(Silicon and PS) ....................... 14 7.8  Stethoscope construction ..................................................................... 16 7.9  OLED display shows information ......................................................... 17 8.  Operation Description ............................................................................... 18 9.  DS101_DM Software (Data Management) ................................................ 26 10.  Product Parts List .................................................................................. 38 11.  Cleaning .................................................................................................. 39 12.  Warranty ................................................................................................. 40 13.  Troubleshooting ..................................................................................... 40 14.  Maintenance and Repair ........................................................................ 42 15.  Transportation, Storage, and Disposal ................................................ 42 16.  Specification........................................................................................... 43 17.  $SSHQGL[*XLGDQFHDQG0DQXIDFWXUHU¶V'HFODUDWLRQ . 拗婌! ⯂㛒⭂佑㚠䰌ˤ 18.  FCC and IC Compliance Statement ...................... 拗婌! ⯂㛒⭂佑㚠䰌ˤ9 ġ
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 4 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ1.  Introduction Thank you for choosing our Electronic Stethoscope DS101. This useful stethoscope will be a great aid in your auscultation.  It  has  several  smart  and  friendly  design,  which  makes  it  easy  to  use  and properly fit the needs for users. The design includes an easy-to-use interface that enable the users to approach the patient with one hand. The ear-tips are comfortable  to  wear  with  the  soft  texture.  As  well,  it  could  provide  a  good tightness for reduction of environmental noise to offer a good sound quality for users.  Electronic  Stethoscope  DS101  was  innovated  from  a  group  of  healthcare professionals.  Therefore,  the  user  experience  is  an  important  factor  of designing  the  stethoscope.  We  appreciate  for  your  adoption  of  Electronic Stethoscope DS101 and look forward to your valuable feedback 2.  Safety Information Please read, understand, and follow all safety information contained in these instructions  prior  to  using  this  electronic  stethoscope.  Retain  these instructions for future reference.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 5 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ2.1  Symbol Definitions Explanation of Safety Markings and Symbols  Warning  Consult instructions for use.  Indicates Type BF Equipment: The equipment provides protection against electrical shock and electrical current leakage. Applied parts are considered to be the complete chest-piece with diaphragm.  This  product  and  packing  does  not  contain  natural  rubber latex.  Temperature Limit  This  product  contains  electrical  and  electronic  components and must not be disposed of using standard refuse collection. Please consult local directives for disposal of electrical and electronic equipment.  This product uses wireless Bluetooth communication. Rx only  Federal law restricts this device to sale by or on the order of a physician.  Explanation of Signal Word Consequences NOTICE Indicates  a  hazardous  situation,  which,  if  not  avoided,  may result in property damage. WARNING Indicates a hazardous situation, which, if not avoided, could result in minor injury and/or property damage.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 6 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ2.2  Important Safety Information NOTICE z  To  reduce  the  risks  associated  with  environmental  contamination  follow applicable regulations in local when disposing of this stethoscope. Properly dispose of, or recycle, spent batteries. z No  modification  of  this  device  is  allowed.  Use  only  authorized  service personal to repair this electronic stethoscope. If user modify by self, solely responsibility for the consequence. z The Electronic Stethoscope DS101 is MR unsafe. Do not use the Electronic Stethoscope DS101 in Magnetic Resonance Imaging (MRI) environment.   WARNING z To reduce the risks associated with an incorrect result, personal injury and  equipment  damage,  stethoscope  shall  be  stored  and  operated  by medical professionals only as instructed in this manual. z To  reduce  the  risks  associated  with  infection  follow  all  cleaning  and disinfecting  instructions  included  in  this  manual.  Establish  and  follow  a cleaning and disinfecting schedule. z To reduce the risks associated with a damage of ear canal, please hold tight the device to avoid sudden falling and make sure that the soft sealing ear-tips are snapped firmly into position.   WARNING z To reduce the risks associated with very strong electromagnetic fields, avoid using the stethoscope near strong radio frequency signals or portable and/or mobile RF devices. The stethoscope might be damaged. If you hear sudden  or  unexpected  sounds,  move  away  from  any  radio  transmitting antennas. z To reduce the risk associated with an electrical shock, do not use the stethoscope on patients without the stethoscope’s diaphragm cover in place. z The  electronic  stethoscope  DS101  contains  a  Bluetooth  Class  2 wireless data link. The maximum radio frequency field strength generated by the stethoscope is below three volts per meter, a level that is considered safe  to  use  with  other  medical  devices.  However,  audio,  video,  and  other similar equipment may cause electromagnetic interference. If such devices are  encountered  and  cause  interference,  immediately  move  Electronic Stethoscope DS101 away from that device. z To reduce the risks associated with a damage of stethoscope, please
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 7 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġput  the  device  into the  pocket  of  physician  gowns  to  avoid  sudden falling, when you put the device hanging on the neck. z Do not use the unauthorized accessories, which would be caused hazard. The accessories use only from IMEDIPLUS provided. z Do  not  immerse  the  stethoscope  in  a  liquid  or  subject  it  to  any sterilization process. The device might be damaged. z Do not use the Electronic Stethoscope DS101 in Magnetic Resonance Imaging  (MRI)  environment.  Because  of  Electronic  Stethoscope  DS101 contain conductive, metallic and magnetic materials. Those materials include headset, wire, connectors and inductors, which are assembled in Electronic Stethoscope. z Do not use for children under two years old. Because the stethoscope chest-piece is designed for use with child, adolescent and adult patients. z Before first use, battery must be charged continuously for at least 8 hours. Failure to do so may shorten the battery's lifetime. z To prevent causing battery leaks or damaging their terminals, carefully follow all instructions regarding the use of batteries. z If battery fluid gets into your eyes, flush your eyes immediately with clear, cold running water and seek medical attention immediately.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 8 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ3.  Product Description When you turn on the Electronic Stethoscope DS101 for the first time, your authorization to operate this handheld electronic stethoscope is necessary for the normal mode of operation. The Electronic Stethoscope DS101 picks up the sounds from the heart, lungs, anterior/posterior chest, abdomen, neck, limbs, arteries, veins and other internal organs from a patient's body. When picking up the sounds, the phonogram of sounds could simultaneously display after pushing the button 'OK' or 'REC' for recording. When you auscultate with DS101, the sounds are conducted simultaneously to the user's ears bilaterally by active speaker embedded at the bottom of the DS101. At the meantime, sound processing is operated with the aid of a digital signal processor.  The one-hand users interface includes a full-color OLED display, below the OLED display, it has four way button and OK button, a tube connector for output of sounds at the inferior part, and recording button is on the top of OLED display. After turn on the Electronic Stethoscope DS101 and connected with a wireless device by Bluetooth Class 2, the Electronic Stethoscope DS101 could transmit digital data of recorded sounds via Bluetooth. The effective range of Bluetooth transmission will be influenced when some objects blocking between The Electronic Stethoscope DS101 and the connected laptop. (Such as wall, human big objectives as barrier) Reduce the distance or allow the line of sight between The Electronic Stethoscope DS101 and the connected laptop will improve the Bluetooth connection. The DS101 does not incorporate any off-the-shelf (OTS) software. The recorded audio data only can be replayed by The Electronic Stethoscope, and the speaker of effective range from 20 to 1000Hz. The Electronic Stethoscope DS101 operates on two AAA1.2V rechargeable battery with an include power management system to prolong the battery life.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 9 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ4.  Intended Use The Electronic Stethoscope DS101 is intended for the detection, amplification and recording of sounds from the heart, lungs, anterior and posterior chest, abdomen, neck, limbs, arteries, veins and other internal organs with selective frequency ranges. And the stethoscope chest-piece is designed for use with child, adolescent and adult patients. It is used for any subject undergoing a physical  examination and  intended  only for  medical diagnostic purposes in clinic or hospital.  5.  Operator Profile The Electronic Stethoscope DS101 is designed to be used by anyone who wishes to listen to the sounds as described in the Intended Use section above. The  user  manual  provides  complete  information  on  how  to  operate  the Electronic Stethoscope DS101. Additional operating training is not proposed. 6.  Patient Privacy The privacy of patient health information may be protected by state, federal, or international/foreign laws that regulate how such information can be used, stored, transmitted, and disclosed. This system employs security features that are compliant with HIPAA policies. Third party access may be prohibited to such information without obtaining written authorization from the patient.  The  user  is  fully  responsible  for  understanding  and  following  all  laws  that regulate storage, transmission, and disclosure of any electronic patient data through the use of software. If the user becomes unable to comply with a law or restriction that applies to use and disclosure of such data, the user should not proceed to collect or save such information. This  application  may  require  entry  of  individually  identifiable  health information in order to function. Records are stored and recalled through the
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 10 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġuse  of  patient  name,  date  of  birth,  and/or  patient  ID  #.  By  entering  this information, the user assumes any and all risks of and liabilities incurred with using or transmitting such information. 7.  Instructions for Use Please read through the user manual carefully before using the product and operate it according to the user manual. It is advised that you should keep this manual for reference anytime. 7.1  Stethoscope Interface         7.2  Replacing Battery According to Figure 1, open the battery compartment cover by pulling down the notch on the cover, and remove the old battery by lifting it. Replace the new battery with two AAA rechargeable battery. Make sure inserting the new battery with right position that has notice marked on the inside, then remount the cover after replacing.        DEVICE   HEADSET
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 11 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ         Figure 1  IMPORTANT!  Please turn off the system before taking out the battery.  NOTICE: The Electronic Stethoscope DS101 is available to install alkaline or Ni-MH batteries, the chart below is voltage that alkaline and Ni-MH battery contained. We highly recommended using rechargeable batteries which contained in the box for longer operational period.    Alkaline  Ni-MH Voltage  1.5 V  1.2 V   WARNING: Do not use a battery if it is cracked or broken. 7.3  Removing and applying the eartube. As shown in the Figure 2, please tightly hold the device for replacing the ear tubing. Twist the device to counter-clockwise direction to remove the ear tubing. Please put the ear tubing on the safer position in case of the unnecessary falling damage. Align the new ear tubing with the two triangle
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 12 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġmarks on the device and directly insert it into the device. Make sure the ear tubing completely insert into the device with the arrow mark are matching. Figure 2 7.4  Removing and applying the ear-tip. The ear-tips should point in the forward direction as you insert them into your ear  canals.  When  ear-tips  are  properly  positioned,  diaphragm  will  face towards your body, as shown in the Figure 3.  Figure 3  The user can pull ear-tips away from the eartube to remove the ear-tips, as shown in Figure 4.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 13 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġThe user can push ear-tip firmly onto eartube to apply new ear-tips, as shown in Figure 4. Figure 4    7.5  Adjust Headset for Comfort To reduce the spring tension in the headset, hold each eartube at the bend part  near  the  ear-tips  and  gradually  pull  apart  until  fully  extended  (180 degrees), as follows. To increase spring tension, grasp the headset with one hand where the metal eartube enter the plastic tubing, and squeeze until the plastic tubing on one eartube touches the other. Repeat as necessary, as shown in Figure 5.    Reduce Tension Increase Tension  Figure 5  (DUWXEH (DUWLS (DUWLS (DUWXEH $SSO\(DUWLS 5HPRYH(DUWLS
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 14 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ7.6  Replacing the chestpiece As the Figure 6 shows the position of the chestpiece. Please tightly hold the device  for  replacing  the  chestpiece.  Twist  the  device  to  counter-clockwise direction and remove the chestpiece. Please put the chestpiece on the safer position in case of the unnecessary falling damage. Align the new chestpiece with the two triangle marks on the device and directly insert it into the device. Make sure the chestpiece completely insert into the device until hearing the click sound.               Figure 6  7.7  Replacing the disposable diaphragm(Silicon and PS) As shown in the Figure 7, please hold the device and chestpiece tightly for removing the diaphragm. Pull down and  remove the disposable diaphragm (Silicon) and dispose of it into medical waste bucket. To replace the new one, place the new diaphragm inside the rim, make sure the ring of the diaphragm is property and smoothly fit inside the rim groove.      DIAPHRAGM WITH CHESTPIECEġ
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 15 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġġġġġġġġġġġġġFigure 7 As shown in the Figure 8, please hold the device and chestpiece tightly for removing the diaphragm. Pull down and  remove the disposable diaphragm (PS) and dispose of it into medical waste bucket. To replace the new one, tear the  new  diaphragm  package,  hold  the  device  directly  bucked  up  the diaphragm, and make sure the diaphragm is completely tie up with the device until hearing the click sound. Figure 8  DIAPHRAGMġCHESTPIECEġNEW DIAPHRAGMġ
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 16 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ7.8  Stethoscope construction   3RZHU%XWWRQ 7RWXUQRQWKHGHYLFHRUHQWHUWKHVOHHSPRGH 5HFRUGLQJ%XWWRQ 'XULQJDXVFXOWDWLRQLQWKH+20(SDJHSUHVVUHFRUGLQJEXWWRQWRUHFRUGDXVFXOWDWLRQVRXQGVRIVHFRQGV )LOWHU0RGHV6ZLWFK 'XULQJDXVFXOWDWLRQLQWKH+20(SDJHDQGSOD\EDFNWKHUHFRUGHGVRXQGWUDFNWKLVEXWWRQFDQVHOHFWRQHRIWKHDXVFXOWDWLRQILOWHUPRGHLQFOXGLQJ³%HOO´³'LDSKUDJP´DQG³:LGH´PRGHV )RXUZD\%XWWRQDQG2.%XWWRQ z 7KH³)RXUZD\´EXWWRQLVXVHGIRUVHOHFWLRQ z 7KH³5LJKW´DQG³/HIW´NH\VDUHXVHGWRHQWHURUH[LWWKHSDJHV z 7KH³8S´DQG³'RZQ´NH\VDUHXVHGWRDGMXVWWKHVRXQGDPSOLILFDWLRQOHYHO8VLQJWKH³8S´DQG³'RZQ´FDQPRYHWKHLQGLFDWRUXSZDUGDQGGRZQZDUG z 7KH³2.´EXWWRQ5HGNH\LVWRVHWDQGFRQILUPWKHVHOHFWLRQLWHP 2UJDQ3RVLWLRQ6ZLWFK 7KH ³2UJDQ 3RVLWLRQ 6ZLWFK´ LV XVHG WR FKDQJH WKH RUJDQ SRVLWLRQV among³+HDUW´ ³/XQJV´³1HFN´DQG³%RZHO´  RIGHT POWER ON/OFF ORGAN POSITION SWITCH LEFT OK FREQUENCY MODE VOLUME RECORDING BUTTONġ
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 17 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ7.9  OLED display shows information   Volume Level Date and Time Organ Position Auscultation Position (Red Point is Under Auscultation and Recording)  Heart Rate Auscultation Modes B/D/W Bluetooth Battery Statusġ
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 18 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ8.  Operation Description ¾ Power Button (Switch On / Sleep Mode)  Power  ON/OFF:  As  the  diagram  1  shows  the  position  of  power  button. Depressing and releasing the power button for three seconds to turn on and  off  the  stethoscope.  The  information  shows  up  on  the  screen  to presents  the  power  is  on.  Turn  off  the  device  and  the  screen  presents black.       Diagram 1  ¾ Sleep mode     WKtZ
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 19 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġz  In the menu, press “UP”/”DOWN” to scroll to the “SLEEP SET”, then press the “OK” button. Here has “two minutes” , ”five minutes” and ”ten minutes” you can choose. Use “UP”/”DOWN” to choose and then press the “OK” button to confirm. The stethoscope will be in the sleep mode if you don’t use it at the certain time. Press “POWER ON/OFF” again to wake it up.  Diagram 2 ¾ Enter the  menu: z  Press “RIGHT” for 3 seconds to enter the menu. As shown in the diagram 3, play backˣrecord time setˣsleep time setˣdate and time setˣdefault reset and product info.  z  Product information will be displayed on the screen.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 20 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġDiagram 3ġ¾ Record time set z  In the menu, press “UP /DOWN” button to scroll to the “RECORD TIME SET”. As shown in the diagram 6, then press “UP /DOWN” button to scroll to the record length then press ”OK”, as shown in the diagram 4. Here has “10 seconds”, “20 seconds”, “30 seconds” and “40 seconds”.  ġ Diagram 4 ¾ Date & Time Set z  In the menu, press “UP /DOWN” button to scroll to the “DATE TIME SET” then press “OK” to set the date and  time. As shown in the  diagram 5, “LEFT/RIGHT” buttons are used for moving position, “UP/DOWN” button for increase and decrease the numbers. Press “OK” to save the setting.  ġ
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 21 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġġġġġġġġġġġġDiagram 5 ¾ Battery set z  In the menu, press “UP /DOWN” button to scroll to the “BATTERY SET” then  press  “OK”  to  set  the  battery.  As  shown  in  the  diagram  6,  “UP /DOWN” buttons are used for choose two different types of battery. The user can choose “Alkaline” or “Ni-MH” based on which types of battery installed. Press “OK” to save the setting. The default batteries in the box are Ni-MH battery. Diagram 6 NOTICE 烉烉烉烉There are two selections of battery: Alkaline and Ni-MH.  The default setting of battery selection is Ni-MH battery. An inaccurate battery indicator will show  on  screen if you change with other  kinds of battery without switch to the correct selection.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 22 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ¾ Default  z  In  the    menu,  press  “UP  /DOWN”  button  to  scroll  to  the  “DEFAULT RESET” then press ”OK” to enter to default reset page, as shown in the diagram 7. Press “YES” if you’ve already make sure to reset to default setting. This function can help you default the unexpected condition and reset.  Diagram 7  Factory Default Setting Table Parameters  Default Idle time of “Sleeping Mode” before going to sleep  2MIN (2 minutes) Filter mode group  “BDW” group Auscultation organ position  HEART Filter Mode  B Mode Amplification level  Level 5 Recording number  Empty  Battery Setting  Ni-MH ¾ Product Information The  stethoscope  show  the  software  version  and  product  name  on  the “PRODUCT INFO” page.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 23 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ Diagram 8  ¾ Organs setting z  “ORGAN” button is used for organs setting. As shown in diagram 9, press and  release  the  “ORGAN”  button  to  switch  the  organs  pattern.  For example: Heart Æ Lung  Æ Prior chest Æ Neck Æ Bowelˤ  Diagram 9 ¾ Sound frequency mode
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 24 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġz  “BDW” is used for sound frequency mode. As shown in diagram 10, press and release the “BDW” button to switch the frequency mode. For example: B (Bell mode) Æ D (Diaphragm mode) Æ W (Wide mode) Diagram 10 ġ¾ Volume control: z  As shown in diagram 11, press “UP” to increase the sound level and press “DOWN” to decrease the sound level. Keep pressing “DOWN” to decrease the volume until it turns into “MUTE” mode.  ġDiagram 11 ¾ Bluetooth connect
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 25 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġz  As shown in the diagram 12,ġwhen DS101 successfully connected with the device, the red box in the Bluetooth icon will disappear. Diagram 12  ¾ Recording the Auscultation Sound  z  The recording button is on the top of the display. Press the   recording button        to  record  sound  and  the  Phonocardiogram  will  show  on  the screen. The red horizontal red bar presents the recording time shown at the  bottom  on  the  screen.  The  default  setting for  recording  time  is  10 seconds, after recording the sound track the screen will go back to the home page.    WARNING: To avoid the damage of ears, do not tap hard or scratch the chest-piece  with  diaphragm  while  wearing  the  ear-tips  with  the stethoscope powered on. ¾ Playing Back a Sound Track
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 26 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġz  In the menu, press “UP /DOWN” button to scroll to the “PLAYBACK” then press”OK”  to  enter  playlist.  File  name  is  YYYYMMDD_HHMMSS.  As shown  in  the  diagram  13,  press  “UP/DOWN”  button  to  scroll  to”  FILE NAME” and confirm with “OK” to check the organ mapping(as shown in the  diagram).  Press  “OK”  again  to  play  back  the  sound  track.  The Phonocardiogram  will  be  shown  on  the  screen  while  a  sound  track  is playing. Press “LEFT” to return to the menu.  Diagram 13  9.  DS101_DM Software (Data Management) ¾ Installation for Android System Turn on the Android App Store using a supported mobile device. Ensure that the device is connected to the internet. Follow the instructions to download the App and wait until it has finished installing. ¾ Create the first account First,  create  the  account  to  access  the  DS101_DM  Software  (Data Management) and also, keep patients data in your account. Now turn on the DS101_DM Software (Data Management) on the mobile device. Enter your   ġ
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 27 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġown user name and password.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 28 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ¾ Sign in After create a first account, use that account to sign-in. Please type your user name and password correctly.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 29 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ ¾ Bluetooth Pairing Bluetooth must be enabled in the device Bluetooth settings in the DS101_DM Software App.  First, enable Bluetooth on the selected mobile device. On the mobile device go to Settings > Bluetooth > and tap the slider to turn Bluetooth ON. Searching the mobile device’s name and tap to pair.  Then,  turn  on  the  DS101_DM  Software  (Data  Management)  and  tap  the Bluetooth symbol icon to display the Bluetooth devices. You can tap “Scan” if the paired Bluetooth device is not displayed. After the paired Bluetooth device is displayed, tap on it to connect with the device.  Scan Tap to scan the paired Bluetooth
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 30 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġThe system will pop-up, asking to pair with the stethoscope, if it is the true one, tap “Pair” to confirm.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 31 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ¾ Using the app to receive recordings  After paired with the stethoscope, the mobile device page will turn to record received page. The mobile device is now ready to receive sounds from the DS101.  Tap  “RECEIVE”  button  and  the  DS101_DM  Software  (Data Management) start to receive recordings from DS101. If Bluetooth pairing is unsuccessful, the Bluetooth mark will flash on the OLED screen of DS101 and no sounds will be recorded. If the Bluetooth connection is successful the mark will keep in bright blue of the device.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 32 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ¾ Using the app to transmit recordings to DS101  Turn on the DS101_DM Software (Data Management) and log in. Ensure that the DS101 Device is paired to the mobile device (See Section 8). In the home screen, press “Transmit” and the original record will transmit back to DS101.  NOTICE: For showing better sounds quality, we highly recommend transmit recordings back to DS101 and listen with eartube.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 33 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ9.1  The Main Recording Page The Main Recording Page allows users to view audio data captured by DS101, begin the recording process, retrieve patient specific data, or adjust settings. Audio data is represented in real-time as a phonocardiogram. A period of recording is 10-second intervals.           Receive Tap to receive recordings from DS101 Audio wave form Received from the DS101 Cancel Tap to cancel transmission and disconnect from DS101 Organ Mark Indicate the listening position Recordings How many recordings to transmit and received
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 34 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ9.2  Records Page The recordings received from DS101 will save to records page. Tab on any recording to review the detail information.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 35 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ9.3  Review Page More information on a specific recording can be viewed by tapping on a recording listing. This page displays the recording number, organ mark, recording time, operator ID, and clinical opinion. User can add suggestion or diagnosis opinion on it.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 36 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġThis also includes a waveform of the recording with zoom in / zoom out, and playback the sound. 9.4  Setup Page In setup page, it can change user name, email, belonging company, and belonging department.    Change Password Tap to change Sign-out Tap to sign-out
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 37 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ ¾ Other Operating Considerations z  Operating  range  is  32ºF  to  104ºF  (0ºC  to  40ºC),  15  to  93%  relative humidity. z  Maximum operating altitude is 2000m. z  Maximum expected service life is 5 years. z  Storage and transport range is -4ºF to 158ºF (-20ºC to 70ºC), 0 to 93% relative humidity. z  To  keep  the  life  of  your  electronic  stethoscope,  please  avoid  operating under extremely hot and extremely cold condition.   z  Don’s use solvents and oils to prevent unexpected hazards. z  Remove  the  battery  if  the  electronic  stethoscope  will  not  be  used  for several months. z  Failure to follow care and maintenance recommendations could result in damage to the internal components of the Electronic Stethoscope DS101. Internal damage could cause malfunction of the product, ranging from a slight decrease in auditory response to complete failure of the product. NOTICE 烉烉烉烉If you experience any problems with the Electronic Stethoscope DS101, do not attempt to repair it yourself. Please notify our customer service center for directions on shipping and receiving.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 38 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ10. Product Parts List 1.  '6'HYLFH,WFRQVLVWV RIFKHVWSLHFHZLWK GLDSKUDJP VFUHHQ LQWXLWLYH NH\SDGDQGHDUWXEHFRQQHFWRURIDXGLRRXWSXW 2.  '6 +HDGVHW ,QFOXGLQJ HDUWXEH FRQQHFWRUDQGHDUWLSV   3.  'LDSKUDJP  4.  $$$9%DWWHU\   5.  %DWWHU\&KDUJHUġ
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 39 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġġ6.  $FFHVVDU\3DFNDJHLQFOXGHVWZRSDLUVRIHDUWLSVWZR$$$$ONDOLQHUHFKDUJHDEOHEDWWHULHVġġWARNING:  Do  not  use  the  unauthorized  accessories  which  would lead to unexpected hazards.  11. Cleaning z  Electronic stethoscope:
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 40 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ1)   Before start to cleaning, please check the tubbing connector and all structure of stethoscope are stable to avoid liquid infiltration. NOTICE 烉To  clean  the  chestpiece,  you  may  take  off  the  diaphragm  for  the sterilizing process. 1)  Avoid directly wiping up with alcohol or detergent solution in case of the unnecessary damage, spray 70%~75% alcohol solution on the dry, clean tissue paper or cotton sheet that we highly recommended. 2)  Wipe the electronic stethoscope. 3)  After  wiping  out  the  dust  and  dirt,  please  check  the  electronic stethoscope is working as usual. z  Ear tubing and ear-tips: It can be wiped clean with alcohol. Ear-tips may be removed for the advanced cleaning and disinfection. Diaphragm:  you  can  wipe  the  diaphragm  with  70%~75%  alcohol solution on the dry,  clean tissue paper or cotton  sheet  that we highly recommended. Otherwise, replace the new diaphragms after the device is dirty or used in high contamination patient.   WARNING: To reduce the risk of infection, cleaning of stethoscope should be done between each patient use.  WARNING: Do not immerse the stethoscope in a liquid or subject it to any sterilization process. The device might be damaged. 12. Warranty Your Electronic Stethoscope is warranted against any defects in material and manufacture for a period of one year. If a material or manufacturing defect is discovered during the warranty period, repairs will be made without charge upon the return of the instrument to vendor, except in cases of obvious abuse or accidental damage. 13. Troubleshooting
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 41 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġItem Questions  Answer 1.  No “Powered”, after “Turn ON”.  Please  check  battery  whether properly  installed,  and  then  try again after reinstall the battery. 2.  No “Powered”, after “Turn ON”.  Please  replace  a  new  one battery, and then try again after reinstall battery. 3.  No  “auscultation  sound”,  after  “Turn ON”. Please  check  headset  whether properly  installed,  and  then  try again after reassembly headset. 4.  No  “auscultation  sound”,  after  “Turn ON”. Please  use  the  “amplification level  control”  button  to  adjust amplification level properly. 5.  The  screen  displays  “DATE WARNING” after “Turn ON” This  stands  for  unsetting  of  the date and the time. Please refer to the  section  "Setting  Date” (setting  date  section  6-8)  to  set date. 6.  The  device  has  no  response  when you are operating the device. Please  reinsert  the  battery,  and then  make  sure  the  device  has response  when  you  are operating.  IMPORTANT! •  If you have tried all of the solutions to the questions and that still failed to solve your problem, please call local service branches for assistance.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 42 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ14. Maintenance and Repair For  maintenance  or  repair  Services,  please  register  your  name,  physical address, e-mail address, and phone number with your Electronic Stethoscope DS101. NOTICE:  No  modification  of  this  device  is  allowed.  Use  only  authorized service personnel to repair this electric stethoscope. If user modify by  himself,  the  user  will  take  all  of  the  responsibility  for  the consequence. If you have any questions or comments, please feel free to contact Customer Service Center. In the Taiwan (R.O.C.): IMEDIPLUS Inc. Address: 2F, 12, ShengYi Rd. Sec. 2, Chupei City, Hsinchu County 30261, Taiwan (R.O.C.) Email: service@IMEDIPLUS.com Tel: +886-3-658-7700 Fax +886-3-658-9535 http://www.imediplus.com 15. Transportation, Storage, and Disposal  Transportation and Storage z  General  transportation  of  the  unit  should  correspond  to  the  conditions outlined in the 'Other Operating Considerations' section of this manual. z  The Electronic Stethoscope DS101 needs to be sent to an authorized service center for inspection and repair. The storage environment conditions must be follow the 'Other Operating Considerations' section of this manual.  Disposal
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 43 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġYou shall properly dispose of the Electronic Stethoscope and follow the local regulations.  The  AAA  1.2V  rechargeable  battery  must  be  disposed  of separately or recycled from regular waste.  NOTICE: To reduce the risks associated with environmental contamination, we need to follow the applicable regulations in local when disposing of this stethoscope.  The  AAA  1.2V  rechargeable  battery  must  be  disposed  of separately or recycled from regular waste.  16. Specification /D/W>h^ůĞĐƚƌŽŶŝĐ^ƚĞƚŚŽƐĐŽƉĞ/D/W>h^ůĞĐƚƌŽŶŝĐ^ƚĞƚŚŽƐĐŽƉĞ/D/W>h^ůĞĐƚƌŽŶŝĐ^ƚĞƚŚŽƐĐŽƉĞ/D/W>h^ůĞĐƚƌŽŶŝĐ^ƚĞƚŚŽƐĐŽƉĞ^ϭϬϭWƌŽĚƵĐƚ^ƉĞĐŝĨŝĐĂƚŝŽŶĂƚƚĞƌŝĞƐŶĐůŽƐĞĚĂƚƚĞƌŝĞƐŶĐůŽƐĞĚĂƚƚĞƌŝĞƐŶĐůŽƐĞĚĂƚƚĞƌŝĞƐŶĐůŽƐĞĚ ϭ͘ϮsůŬĂůŝŶĞͬϭ͘ϱsEŝͲD,ĂƚƚĞƌLJĂƚƚĞƌLJŝŶĚŝĐĂƚŝŽŶĂƚƚĞƌLJŝŶĚŝĐĂƚŝŽŶĂƚƚĞƌLJŝŶĚŝĐĂƚŝŽŶĂƚƚĞƌLJŝŶĚŝĐĂƚŝŽŶϭϬϬйͬϳϱйͬϱϬйͬϮϱйDŽŶŝƚŽƌďĂƚƚĞƌLJůĞǀĞůĚĞŐƌĞĞƐDŽŶŝƚŽƌďĂƚƚĞƌLJůĞǀĞůĚĞŐƌĞĞƐDŽŶŝƚŽƌďĂƚƚĞƌLJůĞǀĞůĚĞŐƌĞĞƐDŽŶŝƚŽƌďĂƚƚĞƌLJůĞǀĞůĚĞŐƌĞĞƐϰĚĞŐƌĞĞƐŽŶƚŝŶƵŽƵƐŽƉĞƌĂƚŝŽŶǁŝƚŚĂůůŽŶƚŝŶƵŽƵƐŽƉĞƌĂƚŝŽŶǁŝƚŚĂůůŽŶƚŝŶƵŽƵƐŽƉĞƌĂƚŝŽŶǁŝƚŚĂůůŽŶƚŝŶƵŽƵƐŽƉĞƌĂƚŝŽŶǁŝƚŚĂůůĨƵŶĐƚŝŽŶƐĨƵŶĐƚŝŽŶƐĨƵŶĐƚŝŽŶƐĨƵŶĐƚŝŽŶƐϭϬŚŽƵƌƐŚĞƐƚŚĞƐƚŚĞƐƚŚĞƐƚͲͲͲͲƉŝĞĐĞdĞĐŚŶŽůŽŐLJƉŝĞĐĞdĞĐŚŶŽůŽŐLJƉŝĞĐĞdĞĐŚŶŽůŽŐLJƉŝĞĐĞdĞĐŚŶŽůŽŐLJŚĂŶŐĞĂďůĞĐŚĞƐƚͲƉŝĞĐĞĞǀŝĐĞŝŵĞŶƐŝŽŶĞǀŝĐĞŝŵĞŶƐŝŽŶĞǀŝĐĞŝŵĞŶƐŝŽŶĞǀŝĐĞŝŵĞŶƐŝŽŶϭϰϲdžϱϬdžϯϵ͘ϱŵŵŚĞƐƚŚĞƐƚŚĞƐƚŚĞƐƚͲͲͲͲƉŝĞĐĞtĞŝŐŚƚƉŝĞĐĞtĞŝŐŚƚƉŝĞĐĞtĞŝŐŚƚƉŝĞĐĞtĞŝŐŚƚϮϯŐůŝŶŝĐĂůƌĞĂůŝŶŝĐĂůƌĞĂůŝŶŝĐĂůƌĞĂůŝŶŝĐĂůƌĞĂƵƐĐƵůƚĂƚŝŽŶtĂƚĞƌtĂƚĞƌtĂƚĞƌtĂƚĞƌͲͲͲͲƉƌŽŽĨƌĞƋƵŝƌĞŵĞŶƚƉƌŽŽĨƌĞƋƵŝƌĞŵĞŶƚƉƌŽŽĨƌĞƋƵŝƌĞŵĞŶƚƉƌŽŽĨƌĞƋƵŝƌĞŵĞŶƚ/Wyϰ^ĐƌĞĞŶ^ĐƌĞĞŶ^ĐƌĞĞŶ^ĐƌĞĞŶK>ϭ͘ϰϲ͟&ƵůůŽůŽƌϭϮϴdžϭϮϴZ'&ůĂƐŚŵĞŵŽƌLJ&ůĂƐŚŵĞŵŽƌLJ&ůĂƐŚŵĞŵŽƌLJ&ůĂƐŚŵĞŵŽƌLJϭϮϴDdŚƌĞĞ&ŝůƚĞƌDŽĚĞƐdŚƌĞĞ&ŝůƚĞƌDŽĚĞƐdŚƌĞĞ&ŝůƚĞƌDŽĚĞƐdŚƌĞĞ&ŝůƚĞƌDŽĚĞƐͬͬtDŽĚĞ&ƌĞƋƵĞŶĐLJZĂŶŐĞDŽĚĞ&ƌĞƋƵĞŶĐLJZĂŶŐĞDŽĚĞ&ƌĞƋƵĞŶĐLJZĂŶŐĞDŽĚĞ&ƌĞƋƵĞŶĐLJZĂŶŐĞĞůů;ϮϬͲϮϬϬ,njͿˣŝĂƉŚƌĂŐŵ;ϭϬϬͲϱϬϬ,njͿĂŶĚtŝĚĞ;ϮϬͲϭϬϬϬ,njͿZĞĐŽƌĚŝŶŐWŽƐŝƚŝŽŶĐŽŶƚƌŽůZĞĐŽƌĚŝŶŐWŽƐŝƚŝŽŶĐŽŶƚƌŽůZĞĐŽƌĚŝŶŐWŽƐŝƚŝŽŶĐŽŶƚƌŽůZĞĐŽƌĚŝŶŐWŽƐŝƚŝŽŶĐŽŶƚƌŽůɤɦsŽůƵŵĞĐŽŶƚƌŽůsŽůƵŵĞĐŽŶƚƌŽůsŽůƵŵĞĐŽŶƚƌŽůsŽůƵŵĞĐŽŶƚƌŽůɥɧġsŽůƵŵĞůĞǀĞůĚĞŐƌĞĞsŽůƵŵĞůĞǀĞůĚĞŐƌĞĞsŽůƵŵĞůĞǀĞůĚĞŐƌĞĞsŽůƵŵĞůĞǀĞůĚĞŐƌĞĞϭϬůĞǀĞů
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 44 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġZĞĐŽƌĚŝŶŐZĞĐŽƌĚŝŶŐZĞĐŽƌĚŝŶŐZĞĐŽƌĚŝŶŐƵƐĐƵůƚĂƚŝŽŶKƌŐĂŶĂŶĚƵƐĐƵůƚĂƚŝŽŶKƌŐĂŶĂŶĚƵƐĐƵůƚĂƚŝŽŶKƌŐĂŶĂŶĚƵƐĐƵůƚĂƚŝŽŶKƌŐĂŶĂŶĚWŽƐŝƚŝŽŶĨŽƌ^ŽƵŶĚdƌĂĐŬWŽƐŝƚŝŽŶĨŽƌ^ŽƵŶĚdƌĂĐŬWŽƐŝƚŝŽŶĨŽƌ^ŽƵŶĚdƌĂĐŬWŽƐŝƚŝŽŶĨŽƌ^ŽƵŶĚdƌĂĐŬzĞƐZĞĐŽƌĚŝŶŐƐĞƚƚŝŶŐZĞĐŽƌĚŝŶŐƐĞƚƚŝŶŐZĞĐŽƌĚŝŶŐƐĞƚƚŝŶŐZĞĐŽƌĚŝŶŐƐĞƚƚŝŶŐϭϬƐĞĐ͕ϮϬƐĞĐ͕ϯϬƐĞĐ͕ϰϬƐĞĐZĞĐŽƌĚŝŶŐƉĂƵƐĞZĞĐŽƌĚŝŶŐƉĂƵƐĞZĞĐŽƌĚŝŶŐƉĂƵƐĞZĞĐŽƌĚŝŶŐƉĂƵƐĞхϱƐĞĐdŝŵĞŝƐƉůĂLJdŝŵĞŝƐƉůĂLJdŝŵĞŝƐƉůĂLJdŝŵĞŝƐƉůĂLJϬϬ͗ϬϬ͗ϬϬ;ŚŽƵƌ͗ŵŝŶƵƚĞƐ͗ƐĞĐŽŶĚͿĂƚĞŝƐƉůĂLJĂƚĞŝƐƉůĂLJĂƚĞŝƐƉůĂLJĂƚĞŝƐƉůĂLJyyyyͲyyͲyy;LJĞĂƌͲŵŽŶƚŚͲĚĂƚĞͿKƌŐĂŶŝƐƉůĂLJKƌŐĂŶŝƐƉůĂLJKƌŐĂŶŝƐƉůĂLJKƌŐĂŶŝƐƉůĂLJ,ĞĂƌƚͬ>ƵŶŐͬWŽƐƚĞƌŝŽƌŚĞƐƚͬEĞĐŬͬŽǁĞů^ůĞĞƉŵŽĚĞ^ůĞĞƉŵŽĚĞ^ůĞĞƉŵŽĚĞ^ůĞĞƉŵŽĚĞϮŵŝŶͬϱŵŝŶͬϭϬŵŝŶͬŶĞǀĞƌ^ůĞĞƉŵŽĚĞǁĂŬĞ^ůĞĞƉŵŽĚĞǁĂŬĞ^ůĞĞƉŵŽĚĞǁĂŬĞ^ůĞĞƉŵŽĚĞǁĂŬĞͲͲͲͲƵƉƵƉƵƉƵƉϮƐĞĐ,ĞĂƌƚZĂƚĞĞƚĞĐƚŝŽŶ,ĞĂƌƚZĂƚĞĞƚĞĐƚŝŽŶ,ĞĂƌƚZĂƚĞĞƚĞĐƚŝŽŶ,ĞĂƌƚZĂƚĞĞƚĞĐƚŝŽŶzĞƐ;,ĞĂƌƚKƌŐĂŶĚŝƐƉůĂLJͿ͕ϯϬͲϭϴϬďƉŵƉŚŽŶŽĐĂƌĚŝŽŐƌĂƉŚLJĚŝƐƉůĂLJƉŚŽŶŽĐĂƌĚŝŽŐƌĂƉŚLJĚŝƐƉůĂLJƉŚŽŶŽĐĂƌĚŝŽŐƌĂƉŚLJĚŝƐƉůĂLJƉŚŽŶŽĐĂƌĚŝŽŐƌĂƉŚLJĚŝƐƉůĂLJzĞƐ͕ϯƐĞĐŽŶĚĚŝƐƉůĂLJĂƚĂtŝƌĂƚĂtŝƌĂƚĂtŝƌĂƚĂtŝƌĞĞĞĞůĞƐƐdƌĂŶƐĨĞƌůĞƐƐdƌĂŶƐĨĞƌůĞƐƐdƌĂŶƐĨĞƌůĞƐƐdƌĂŶƐĨĞƌůƵĞƚŽŽƚŚϰ͘Ϭ^ŽƵŶĚdƌĂĐŬƐZĞĐŽƌĚŝŶŐ;&ŝůĞƐ^ŽƵŶĚdƌĂĐŬƐZĞĐŽƌĚŝŶŐ;&ŝůĞƐ^ŽƵŶĚdƌĂĐŬƐZĞĐŽƌĚŝŶŐ;&ŝůĞƐ^ŽƵŶĚdƌĂĐŬƐZĞĐŽƌĚŝŶŐ;&ŝůĞƐ^ƚŽƌĂŐĞͿ^ƚŽƌĂŐĞͿ^ƚŽƌĂŐĞͿ^ƚŽƌĂŐĞͿ^ĂǀĞƵƉƚŽϭϲϬϭϬͲƐĞĐŽŶĚƉĂƚŝĞŶƚƐŽƵŶĚƚƌĂĐŬƐ 17. Appendix: Guidance and Manufacturer’s Declaration  Manufacturer’s declaration-electromagnetic emissions The DS101 is intended for use in the electromagnetic environment (for professional healthcare) specified below. The customer or the user of the DS101 should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment-guidance  (for professional healthcare environment) RF emissions CISPR 11  Group 1  The DS101 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11  Class A  The DS101 is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic  purposes. Harmonic emissions  IEC 61000-3-2 Not applicable Voltage fluctuations /flicker emissions IEC 61000-3-3 Not applicable
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 45 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġManufacturer’s declaration-electromagnetic immunity The DS101 is intended for use in the electromagnetic environment (for professional healthcare) specified below. The customer or the user of the DS101 should assure that it is used in such an environment. Immunity test IEC 60601  test level Compliance level Electromagnetic environment-guidance            (for professional healthcare environment) Electrostatic discharge(ESD) IEC 61000-4-2 Contact:s8 kV  Airs2 kV,s4 kV,s8 kV,s15 kV  Contact:s8 kV  Airs2 kV,s4 kV,s8 kV,s15 kV Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30% Electrical fast transient/burst IEC 61000-4-4 + 2kV for power supply lines + 1kV for input/output lines Not applicable Not applicable Mains power quality should be that of a typical professional healthcare environment. Surge IEC 61000-4-5 + 0.5kV, +1kV line(s) to line(s) + 0.5kV, +1kV,+ 2kV line(s) to earth Not applicable Not applicable Mains power quality should be that of a typical professional healthcare environment. Voltage Dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 Voltage dips: 0 % UT; 0,5 cycle             0 % UT; 1 cycle 70 % UT; 25/30 cycles  Voltage interruptions: 0 % UT; 250/300 cycle Voltage dips: Not applicable Not applicable Not applicable  Voltage interruptions: Not applicable  Mains power quality should be that of a typical professional healthcare environment.   If the user of the DS101 requires continued operation during power mains interruptions, it is recommended that the DS101 be powered from an uninterruptible power supply or a battery. Power frequency(50, 60 Hz) magnetic field IEC 61000-4-8 30 A/m 50 Hz or 60 Hz 30 A/m 50 Hz and 60 Hz The DS101 power frequency magnetic fields should be at levels characteristic of a typical location in a typical professional healthcare environment. NOTE     UT is the a.c. mains voltage prior to application of the test level.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 46 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġManufacturer’s declaration-electromagnetic immunity The DS101 is intended for use in the electromagnetic environment (for professional healthcare) specified below. The customer or the user of the DS101 should assure that is used in such and environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment-guidance   (for professional healthcare environment) Conducted RF IEC 61000-4-6        Radiated RF  IEC 61000-4-3 3 Vrms: 0,15 MHz – 80 MHz 6 Vrms:  in ISM bands between 0,15 MHz and 80 MHz   80 % AM at 1 kHz e)   3 V/m 80 MHz – 2,7 GHz b) 80 % AM at 1 kHz c) Not applicable  Not applicable       3 V/m 80 MHz – 2,7 GHz  80 % AM at 1 kHz  Portable and mobile RF communications  equipment should be used no closer to any part of the DS101 including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.    Recommended separation distance: d = 1,2 ¥P d = 1,2 ¥P  80MHz to 800 MHz d = 2,3 ¥P  800MHz to 2,7 GHz   Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m).  Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range.b  Interference may occur in the vicinity of equipment marked with the following symbol:   NOTE1   At 80 MHz and 800 MHz, the higher frequency range applies. NOTE2   These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a   Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the DS101 is used exceeds the applicable RF compliance level above, the DS101 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the DS101 b   Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 47 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġRecommended separation distance between portable and mobile RF communications equipment and the DS101 The DS101 is intended for use in an electromagnetic environment (for professional healthcare) in which radiated RF disturbances are controlled. The customer or the user of the DS101 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the DS101 as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d =1,2¥P 80 MHz to 800 MHz d =1,2¥P 800 MHz to 2,7 GHz d =2,3¥P 0,01  N/A  0,12  0,23 0,1  N/A  0,38  0,73 1  N/A  1,2  2,3 10  N/A  3,8  7,3 100  N/A  12  23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE1  At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE2  These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 48 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġManufacturer’s declaration-electromagnetic immunity Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment The DS101 is intended for use in the electromagnetic environment (for professional healthcare) specified below. The customer or the user of the DS101 should assure that it is used in such an environment. Test frequency (MHz) Band a) (MHz) Service a) Modulation b) Maximum power (W) Distance (m) IMMUNITY TEST LEVEL (V/m) Compliance LEVEL (V/m) (for professional healthcare) 385  380 ʹ390 TETRA 400 Pulse modulation b) 18 Hz 1,8  0,3  27  27 450  430 ʹ 470 GMRS 460, FRS 460 FM c) ˢƲ5 kHz deviation 1 kHz sine 2  0,3  28  28 710 704 ʹ 787 LTE Band 13, 17 Pulse modulation b) 217 Hz 0,2  0,3  9  9 745 780 810 800 ʹ 960 GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 Pulse modulation b) 18 Hz 2  0,3  28  28 870 930 1 720 1 700 ʹ 1 990 GSM 1800; CDMA 1900; GSM 1900;  DECT; LTE Band 1, 3, Pulse modulation b) 217 Hz 2  0,3  28  28 1 845 1 970 2 450  2 400 ʹ 2 570 Bluetooth,  WLAN, 802.11 b/g/n, RFID 2450,  LTE Band 7 Pulse modulation b) 217 Hz 2  0,3  28  28 5 240 5 100 ʹ 5 800 WLAN 802.11 a/n Pulse modulation b) 217 Hz 0,2  0,3  9  9 5 500 5 785 NOTE    If  necessary  to  achieve  the IMMUNITY  TEST  LEVEL, the  distance  between the  transmitting  antenna  and the ME  EQUIPMENT or ME  SYSTEM may be reduced to 1 m. The 1 m test  distance is  permitted by IEC 61000-4-3. a)     For some services,  only the uplink frequencies  are included. b)     The carrier shall  be modulated using a 50  % duty cycle square wave signal. c)     As  an  alternative  to  FM  modulation,  50 %  pulse  modulation at  18  Hz  may  be  used  because  while  it  does not  represent  actual modulation, it  would be  worst case.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 49 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ18. FCC and IC Compliance Statement 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment.  15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. &RQQHFWWKHHTXLSPHQWLQWRDQRXWOHWRQDFLUFXLWGLIIHUHQWIURPWKDWWRZKLFKWKHUHFHLYHULVFRQQHFWHG -Consult the dealer or an experienced radio/TV technician for help.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference and 2) This device must accept any interference received, including interference that may cause undesired operation of the device.  FCC RF Radiation Exposure Statement:   1) This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
 Document Title:  Electronic Stethoscope DS101 User Manual Document No.: DS101-SDUS01-01303 Page: 50 of 50 Product Name: Electronic Stethoscope DS101 Ver.: A1 510(k) File Name: 003_Electronic Stethoscope DS101 User Manual  Date: 2017/8/26 ġġ2) For body worn operation, this device has been tested and meets FCC RF exposure guidelines. When used with an accessory that contains metal may not ensure compliance with FCC RF exposure guidelines. ġġCanada, Industry Canada (IC) This device complies with Industry Canada licence-exempt RSS standard(s).  Operation is subject  to the following two conditions:  (1) This device may not cause interference, and  (2) This device must accept any interference, including interference that may cause undesired operation of the device   Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.   RF Radiation Exposure Statement: For body worn operation, this phone has been tested and meets RF exposure guidelines when used with an accessory that contains no metal. Use of other accessories may not ensure compliance with RF exposure guidelines.  Déclaration de l'exposition aux radiations RF: Pour le fonctionnement du corps, ce téléphone a été testé et répond aux directives d'exposition RF lorsqu'il est utilisé avec un accessoire qui ne contient pas de métal. Utilisation d'autres accessoires peut ne pas assurer le respect des directives d'exposition RF.

Navigation menu