IDT Technology EMR211X-01 BLE connected In/Out Thermometer User Manual EMR211 18 M Cover1

IDT Technology Limited BLE connected In/Out Thermometer EMR211 18 M Cover1

Users Manual

Weather@Home Thermo Bluetooth-enabled ThermometerUSER MANUALEMR211XBAR218HG-18-UM-EN-R1.indd   1 2018/4/13   下午12:14
EN1Weather@Home Thermo Bluetooth-enabled ThermometerModel: EMR211XUSER MANUALCONTENTSIntroduction .............................................................. 2Overview ................................................................... 2  Front view .............................................................. 2  Rear view ............................................................... 2  Remote Sensor (THN132N) ................................... 3Getting started .......................................................... 3  Insert batteries ....................................................... 3Remote sensor...... .................................................... 3  Sensor data transmission ...................................... 4Temperature .............................................................. 4  Ice warning ............................................................. 4Reset .......................................................................... 4Connect with your mobile device ........................... 5  Paring your Thermometer ...................................... 5 Settings .................................................................. 6  View current readings ............................................ 7   View history readings .............................................. 7Optional sensor for additional information ........... 7Precautions ............................................................... 8Specifications ........................................................... 8About oregon scientific ........................................... 9Eu-Declaration of Conformity ................................. 9Disposal Information for Users ............................... 9FCC statement ........................................................ 10EMR211X_M_EU_EN_R6.indd   1 2018/6/13   下午12:05
EN2INTRODUCTIONThank you for selecting our Oregon ScientificTM  Weather@Home Bluetooth-enabled Thermometer, which has changeable display on indoor and outdoor temperature.  NOTE  Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about.OVERVIEWFRONT VIEW123456781.  Outdoor temperature reading (°C/°F)2.  Sensor channel indicator3.  : Sensor reception indicator4.  : outdoor remote sensor battery low5.  Indoor temperature reading (°C/°F)6.  : indoor remote sensor / main unit battery low7.   : BLE connection indicator8.  Ice alert LED indicatorREAR VIEWRESETSET1. 2. 3. 451.  SET: select temperature unit (°C/°F); pair up Bluetooth function2.  : select outdoor channels (1-5); search remote sensor3.  : select outdoor channels (1-5); auto-scan among sensors 4.  RESET: reset the unit to default settings5.  Battery compartmentEMR211X_M_EU_EN_R6.indd   2 2018/6/13   下午12:05
EN3REMOTE SENSOR (THN132N)         1                                                  23451.  LED status indicator2.  Wall mount hole3.  Battery compartment4.  RESET hole5.  CHANNEL switch REFERENCE  Visit our website www.oregonscientific.com to learn more about the compatible sensors.GETTING STARTEDINSERT BATTERIES1.  Remove the battery compartment.2.  Insert the batteries, matching the polarities (+/-).3. Press RESET after each battery change. LOCATION MEANINGOutdoor temperature area Outdoor sensor batteries lowIndoor temperature area Indoor sensor batteries low / main unit batteries lowREMOTE SENSORThe main unit can collect data from up to 5 sensors.To set up the sensor:1.  Open the battery compartment.2.  Select a channel then press RESET.3.  Close the battery door.4.  Place the sensor within 98 ft (30 m) of the main unit using the table stand or wall mount.TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 5 ft (1.5 m); and can shield it from direct sunlight or wet conditions for an accurate reading.1.5 m (5 ft)EMR211X_M_EU_EN_R6.indd   3 2018/6/13   下午12:05
EN4 NOTE  Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.SENSOR DATA TRANSMISSIONTo search for a sensor:1. Press   or   to select among 5 different outdoor channels of remote sensors.2.  Press and hold   for 2 seconds to enforce researching for the selected sensor.To auto-scan among sensors:•   Press and hold   for 2 seconds to enable auto-scan function for all 5 channels. The temperatures will be displayed automatically in sequential order (Channel 1,2,3,4,5)The sensor reception icon at the front of the main unit shows the status:ICON DESCRIPTIONMain unit is searching for sensor(s).A channel has been found.The sensor cannot be found. TIP  The transmission range may vary depending on many factors. You may need to place the sensor(s) in different locations to get the best result(s). TEMPERATURETo select temperature unit:•   Press SET to select °C or °F for temperature readings. ICE WARNING If the channel 1 sensor falls from 37°F to 28°F (3°C to -2°C), LED indicator in the front of the main unit will ash continuously, and will stop ashing once the temperature is out of this range.•   Press   and   at the same time to deactivate the ice alert warning. •   The ice alert warning will be disable/enable again when the temperature falls again from 37°F to 28°F (3°C to -2°C). NOTE  As ice alert is only applicable to channel 1, to prevent flashing of LED, select channel 2-5 on outdoor sensor.RESETPress RESET at the rear of the main unit to return to the default settings.EMR211X_M_EU_EN_R6.indd   4 2018/6/13   下午12:05
EN5CONNECT WITH YOUR MOBILE DEVICEYou can remotely set the thermometer and read the weather information through Bluetooth®4.0 using your mobile device with the downloaded application from the Apple Store. To quickly find the application, type ‘Weather@Home’ as keyword in the search engine. Ensure your mobile device is compatible with iOS 5 or Android 4.3 with Bluetooth®v4.0. PAIRING YOUR THERMOMETERFirst of all, you need to pair your thermometer with your mobile device.   will ash on the screen of the weather station while pairing and be on after successful pairing. To pair up a sensor: At the rear of the main unit, press and hold SET for 2 seconds to enable a pair-up for the main unit. 1. Tap   to enter SETTINGS screen.2.  Tap on STATION area. 3. Tap Pair Up. Searching… displays. If you want to cancel the pairing, tap Cancel. 4.  Once the pairing is successful, it will return to STATION screen. 5.  Tap on each channel to rename it. (Up to 20 characters including space are allowed). Tap   if completed. Tap   to exit. To remove sensor:To remove any sensor from the weather station, Tap Remove station on STATION screen, all the sensors will be removed at the same time. EMR211X_M_EU_EN_R6.indd   5 2018/6/13   下午12:05
EN6To reposition the sensors on screen: 1. On STATION screen, tap  . 2.  Press and hold   at the right side of a sensor. Drag it to your desired position. 3. Tap   to conrm. SETTINGSYou can set your weather station through the application, such as measurement units. The settings are as follows:•   Temperature •   Barometric (not available in EMR211X)•   Rainfall (not available in EMR211X)•   Wind speed (not available in EMR211X)•   Altitude (not available in EMR211X)•   Show unavailable sensor•   Automatically sync time•   Show Sea Level Pressure (not available in EMR211X)To select the measurement unit:1. Tap   to view the measurement unit options. 2.  Tap on your desired unit. 3. Tap   to go back to the previous screen. EMR211X_M_EU_EN_R6.indd   6 2018/6/13   下午12:05
EN7VIEW CURRENT READINGS You can directly view all the      temperature readings from      different sensors through the      application at a time. The      readings are on the HOME     screen.   NOTE  If low battery icon    displays on the screen,    please replace the batteries for    the corresponding device. To show unavailable sensor: If the sensor is out of range, the readings are interrupted and - - (dash mode) displays on the screen. If you do not want to show the unavailable sensor: •   On SETTINGS screen, touch and slide the button to right to turn on the function, or sliding to left to turn it off. To automatically synchronize time: Time and date on your weather station could be automatically synchronized by your mobile device.•   On SETTINGS screen, touch and slide the button to right to turn on the function, or sliding to left to turn it off. VIEW HISTORY READINGSYou can view history through the application. The history could also be presented in graphs (past 24 hours or past 7 days). To view the history:1.  Tap on your desired sensor area on the screen. 2. Tap   to select your desired data or tap   to sort the data by date.   OPTIONAL SENSOR FOR ADDITIONALINFORMATIONBy applying the sensor (Model: BTH Sensor) at the same time, you can also view the following information using your mobile device.•   Weather Forecast •   Air Pressure•   Outdoor Humidity EMR211X_M_EU_EN_R6.indd   7 2018/6/13   下午12:05
EN8 USEFUL REFERENCE  The optional sensor (Model: BTH Sensor) can be purchased from Oregon Scientific.PRECAUTIONS•   Do not subject the unit to excessive force, shock, dust, temperature or humidity.•   Do not cover the ventilation holes with any items such as newspapers, curtains etc.•   Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.•   Do not clean the unit with abrasive or corrosive materials. •   Do not tamper with the unit’s internal components. This invalidates the warranty.•   Only use fresh batteries. Do not mix new and old batteries.•   Images shown in this manual may differ from the actual display.•   When disposing of this product, ensure it is collected separately for special treatment and not as household waste.•   Placement of this product on certain types of wood may result in damage to its nish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer’s care instructions for information.•   The contents of this manual may not be reproduced without the permission of the manufacturer.•   Do not dispose old batteries as unsorted municipal waste.Collection of such waste separately for special treatment  is necessary.•   Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before rst use. NOTE  The technical specifications for this product and the contents of the user manual are subject to change without notice. NOTE  Features and accessories will not be available in all countries. For more information, please contact your local retailer.SPECIFICATIONSTYPE DESCRIPTIONMAIN UNITL x W x H 93 x 68 x 30 mm(3.66 x 2.68 x 1.18 in)Weight 96g (3.39 ounces) include batteryTemperature range -5°C to 50°C (23°F to 122°F)Signal frequency 433 MHzPower 2 x AAA batteriesEMR211X_M_EU_EN_R6.indd   8 2018/6/13   下午12:05
EN9Temperature range for ice alert 3°C to -2°CREMOTE THERMO SENSOR (THN132N)L x W x H 96 x 50 x 22 mm(3.78 x 1.97 x 0.87 in)Weight 62g (2.22 ounces)Transmission range 30 m (98 ft) unobstructedTemperature range -20°C to 60°C (-4°F to 140°F)Power 1 x UM-3 (AA) 1.5V batteriesABOUT OREGON SCIENTIFICVisit our website www.oregonscientific.com to learn more about Oregon Scientific products.For any inquiry, please contact our Customer Services at info@oregonscientific.com.Oregon Scientific Global Distribution Limited reserves the right to interpret and construe any contents, terms and provisions in this user manual and to amend it, at its sole discretion, at any time without prior notice. To the extent that there is any inconsistency between the English version and any other language versions, the English version shall prevail.EU-DECLARATION OF CONFORMITYHereby the manufacturer, Oregon  Scientic  Global  Distribution Limited, declares that the radio equipment type Weather@Home Thermo Bluetooth-enabled Thermometer (Model: EMR211X) is in compliance with 2014/53/EU Directive. The full text of the EU Declaration of Conformity is available at the following internet address:http://global.oregonscientific.com/customerSupport.php   COUNTRIES RED APPROVED COMPLIEDAll EU countries, Switzerland  CHand Norway    NDISPOSAL INFORMATION FOR USERSPursuant to and in accordance with Article 14 of the Directive 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE), and pursuant to and in accordance with Article 20 of the Directive 2013/56/EU of the European Parliament on batteries and accumulators and waste batteries.The barred symbol of the rubbish bin shown on the equipment indicates that, at the end of its useful life, the product must be collected separately from other waste.Please note that the batteries/rechargeable batteries must be removed from the equipment before it is given as waste. To remove the batteries/accumulators refer to the specifications in the user manual. Therefore, any products that have reached the end of their useful life must be given to waste disposal centersEMR211X_M_EU_EN_R6.indd   9 2018/6/13   下午12:05
EN10specializing in separate collection of waste electrical and electronic equipment, or given back to the dealer when purchasing a new WEEE, pursuant to and in accordance with Article 14 as implemented in the country.The adequate separate collection for the subsequent start-up of the equipment sent to be recycled, treated and disposal of in an environmentally compatible way contributes to preventing possible negative effects on the environment and health and optimizes the recycling and reuse of components making up the apparatus.Abusive disposal of the product by the user involves application of the administrative sanctions according to the laws in force.FCC STATEMENTThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference WARNING  Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the  equipment  into  an outlet on  a  circuit  different from that to which the receiver is connected.•  Consult the dealer or an experienced radio / TV technician for help.DECLARATION OF CONFORMITYThe following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com), or on the warranty card for this product) for all inquiries instead.WeName:    Oregon Scientic Inc.Address:          Brea Corporate Park     3020 Saturn St. Suite 200                                         Brea, CA 92821Telephone No.: 1 (888) 950-8889declare that the product Product No.: EMR211X Product Name: Weather@Home Thermo    Bluetooth-enabled Thermometer Manufacturer: Oregon Scientic     Global Distribution LimitedAddress:   Block C, 9/F, Kaiser Estate,   Phase 1, 41 Man Yue St.,            Hung Hom, Kowloon,   Hong Kongis in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.EMR211X_M_EU_EN_R6.indd   10 2018/6/13   下午12:05

Navigation menu