IDS GeoRadar s r l IBIS-SU IBIS Supply Unit User Manual

IDS Ingegneria dei Sistemi SpA IBIS Supply Unit

User Manual

Tot. N° pages = 48    - PRO/010/M1 Rev 4 -  INGEGNERIA DEI SISTEMI S.p.A.   Rev. 1.1 N°doc: MN/2009/071 Config.: IBIS-S-PRCS-OUT-MN   IBIS-S System IMAGE BY INTERFEROMETRIC SURVEY                     Pisa, June 2010  IBIS-S v. 1.0 - User Manual
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  2 / 48 All information contained in this document is property of  IDS.  All rights reserved.  KEY WORDS IBIS-S, INTERFEROMETER, INSTALLATION   SUMMARY IBIS-S system user manual. This document illustrates the contents of the package and the procedures the operator must perform to set up and dismantle the IBIS-S system.   Document Evolution Revision  Date   Reason for change  Rev. 1.0   October 2009  First Edition with Battery information (according to DL 188 dated 20/11/2008) Rev. 1.1  June 2010  Document  revision  for  declarations  for  US  and  Canada  (see RNC 201005097)        Document change record RNC  References   Change description  201005097  Before index  Declarations for US and Canadian customers             HW and SW versions covered by this document IBIS-S apparatus v. 1.0.     Warnings IDS will not be held responsible for the consequences of an improper use of the equipment. IDS will not be held responsible for the consequences of an improper use of the software All information contained in this document is property of IDS.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  3 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Contacts  IDS Ingegneria Dei Sistemi S.p.A. Via Sterpulino, 20 56121 PISA (Loc. Ospedaletto)  Tel: +3905096711 Fax: +39050961721
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  4 / 48 All information contained in this document is property of  IDS.  All rights reserved.  DISCLAIMER  IDS WILL NOT BE HELD RESPONSIBLE FOR THE CONSEQUENCES OF  AN  IMPROPER  USE  OF  THE  EQUIPMENT  AND/OR  THE SOFTWARE.  THIS  SOFTWARE  MAY  INCLUDE  AUTOMATED  DATA PROCESSING AND ANALYSIS TOOLS.  WHILE EVERY EFFORT IS MADE TO ENSURE THE ACCURACY OF THE  INFORMATION  PROVIDED  BY  THOSE  TOOLS,  THEY  MUST NOT  BE  INTENDED  AS  A  SUBSTITUTE  FOR  INTELLIGENT ANALYSIS;  RATHER,  THEY  HAVE  TO  BE  INTENDED  AS  AN ADVISOR AND THE USER MUST NOT COMPLETELY RELY ON THE RESULTS  PROVIDED  BY  THEM  TO  GIVE  THE  COMPLETE ANSWER. IDS INGEGNERIA DEI SISTEMI SPA ASSUMES NO LIABILITY FOR ANY  DIRECT,  INDIRECT,  SPECIAL,  INCIDENTAL  OR CONSEQUENTIAL  DAMAGES  OR  INJURIES  CAUSED  BY  SUCH RELIANCE  ON  THE  ACCURACY,  RELIABILITY,  OR  TIMELESS  OF THE INFORMATION PROVIDED BY THOSE TOOLS. ANY  PERSON  OR  ENTITY  WHO  RELIES  ON  INFORMATION OBTAINED  FROM  THE  AUTOMATED  DATA PROCESSING/ANALYSIS TOOLS ONLY, DOES SO AT  HIS  OR HER OWN RISK.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  5 / 48 All information contained in this document is property of  IDS.  All rights reserved.  SAFETY INFORMATION
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  6 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Warning:  this  equipment  is  destined  for  use  in  industrial  environments (Class  A  apparatus).  In  residential,  commercial  and light  industry environments, this apparatus may generate radio interference: in this case, the  user  may  be  required  to  operate  while  taking  appropriate countermeasures. The apparatus is sensitive to the presence of external electromagnetic fields, which may reduce its performance.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  7 / 48 All information contained in this document is property of  IDS.  All rights reserved.  IMPORTANT NOTE FOR THE US CUSTOMERS Model No.: IBIS-KU FCC ID: UFW-IBIS-KU This device complies with part 90 of the FCC Rules. Caution:  Any  changes  or  modifications  to  this  device  not  explicitly  approved  by  manufacturer  could  void  your authority to operate this equipment. This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an  uncontrolled  environment.  This equipment  should  be  installed  and  operated  with  minimum  20  cm  between  the  radiator  and  your  body.  This transmitter  must  not  be  collocated  or  operating  in  conjunction  with  any  other  antenna  or  transmitter  unless authorized to do so by the FCC.        IMPORTANT NOTE FOR THE CANADIAN CUSTOMERS  Model No.: IBIS-KU IC ID: 8991A-IBISKU This device has been designed to operate with the antennas listed below, and having a maximum gain of 22 dB. Antennas not included in this list or having a gain greater than 22 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms.  IBIS-ANT1-H38V18 IBIS-ANT2-H29V25 IBIS-ANT3-H17V15 IBIS-ANT4-H11V10 IBIS-ANT5-H12V39 IBIS-ANT6-H51V20  Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.  To reduce potential radio interference to  other  users,  the antenna type and its gain  should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  8 / 48 All information contained in this document is property of  IDS.  All rights reserved.   ! WARNING    CLEANING INFORMATION  Before  cleaning  any external parts of  the apparatus,  make sure that  all  cables  have  been  disconnected,  including  the  power supply cable. If a damp cloth is used, make sure it is not too wet, to  avoid  any  damage  to  the  electrical  components  of  the equipment.  Wait  until  the  equipment  is  totally  dry  before reconnecting the cables. The IBIS-S should be cleaned periodically using a damp cloth. Do not use solvents or abrasive detergents. Do  not  apply  liquid  directly  to  the  electrical  contacts  of  the various  connectors. If  a  specific  spray  is  used  to  clean  the  PC TFT monitor, make sure it is not flammable; in any case, do not spray it directly on the screen, instead, spray it onto the cleaning cloth.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  9 / 48 All information contained in this document is property of  IDS.  All rights reserved.     BATTERIES REMOVAL INFORMATION       Laptop Batteries: Manufacturer: PANASONIC Type: Li-ion Ni Characteristics: 10.65V 5.7Ah Removal instructions: 1. turn off the laptop; 2. open the drawer marked with the battery symbol; 3. extract the battery pack by pulling the tab.  Radar batteries: Manufacturer: FIAMM FG21202 Type: rechargeable lead acid, non spillable batteries Characteristics: 12V & 12Ah Removal instructions: 1. disconnect the battery from the instrument: a. pull the connector wings; b. separate the connectors; 2. remove the battery from the cover (optional) by opening the strap.    NOTE:   Batteries must be recycled according to national regulations. Read carefully the warnings and information on the batteries.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  10 / 48 All information contained in this document is property of  IDS.  All rights reserved.    RECICLYING   The crossed out wheeled bin symbol shown on the equipment indicates that the product must be recycled separately from other waste at the end of its useful life.  Separate waste disposal of this product at the end of its useful life will be organised  and  managed  by  IDS.  When  you  decide  to  dispose  of  the equipment, contact IDS and follow the system that IDS has set up to permit the separate collection of the apparatus at its life end.  Adequate  separate  collection  for  its  subsequent  recycling,  treatment  and environmental  friendly  disposal  contribute  towards  avoiding  any unnecessary effects on the environment and to health and favour the reuse or recycling of the materials that make up the equipment. Unauthorised disposal of  this  product  as  unsorted  waste  by  its  possessor  will  lead  to  an administrative penalty foreseen by national regulations.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  11 / 48 All information contained in this document is property of  IDS.  All rights reserved.  WARRANTY CERTIFICATE CONDITIONS  1) IDS  Ingegneria  dei  Sistemi  S.p.A,  hereinafter  referred  to  as  IDS,  warrants  hardware/software products for a period of 12 months from the delivery date to the original customer; 2) The delivery date is certified by the “Warranty Registration Form”; 3) IDS’s hardware products will be free from defects in materials workmanship under normal use and service; 4) IDS’s obligation is limited to repairing or replacing parts or equipment which are returned to IDS, without  alteration  or  further  damage,  and  which  in  IDS  s  judgment,  were  defective  or  became defective during normal use; 5) IDS’ software will have to be installed on a PC according to the requirement of the IDS hardware ( see IDS User’s Guide the Software Data Acquisition); 6) IDS’ s software products designed by IDS for use for IDS hardware products are warranted not to fail to execute their programming instructions due to defects during the warranty period, provided they are properly installed on IDS hardware products. IDS does not warrant if the IDS software will be used and operated in hardware and software combinations not selected by IDS; 7) IDS  does  not  assumes  any  liability  for  any  direct,  indirect,  special,  incidental  or  consequential damages or injuries caused by proper or improper operation of its equipment whether defective or not defective; 8) This software may include automated data processing and analysis tools. While every effort is made to ensure the accuracy of the information provided by those tools, they must not be intended as a substitute for intelligent analysis; rather, they have to be intended as an advisor and the user must not completely rely on the results provided by them to give the complete answer. IDS assumes no liability for any direct, indirect special, incidental or consequential damages or injuries caused by such reliance on the accuracy, reliability, or timeliness of the information provided by those tools. Any  person  or  entity  who  relies  on  information  obtained  from  the  automated  data processing/analysis tools only, does so at his or her own risk; 9) IDS’s warranty does not extend and shall not apply to: a) Products which have been repaired or altered by other than IDS personnel; b) Products which have been subjected to misuse, neglect, accident or improper installation; c) Products  in  which  have  been  installed  Hardware/Software  accessories  not  supplied  by  IDS and/or without any approval by IDS; d) Products  which  have  been  connected  to  equipment  different  from  the  ones  supplied  by  IDS (except the PC data Logger which must conform to IDS specifications; e) Products which have been damaged by natural disaster or calamities. 10) Before returning any equipment to IDS , you have to contact the IDS Customer Care Office that will authorize you to return the material to be repaired; 11)  Once the parts/equipment to be repaired arrive to IDS, IDS may inspect the defective products to verify they are eligible for repair or replacement. All packing must be saved for inspection purpose in order to assist IDS to understand the cause of the defects. IDS, will not be obliged to repair, or replace for products returned as defective but damaged from abuse, misuse, negligence , accident loss or damage in transit; 12) The  final  clients,  is  responsible  for  ensuring  the  defective  products  returned  to  be  properly packaged; 13) The  above  warranty  are  sole  and  exclusive,  and  no  other  warranty,  whether  written  or  oral,  is expressed or implied.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  12 / 48 All information contained in this document is property of  IDS.  All rights reserved. INDEX 1. Introduction........................................................................................................................... 15 1.1 Scope.............................................................................................................................. 15 1.2 Field of application........................................................................................................ 15 1.3 Authorisation for use – national restriction .................................................................. 15 1.4 CE Marking ................................................................................................................... 16 1.5 Acronyms ....................................................................................................................... 16 2. Overview................................................................................................................................. 17 2.1 How to use this manual.................................................................................................. 17 2.2 General description of the IBIS-S system ...................................................................... 17 3. Pack contents ......................................................................................................................... 19 4. IBIS-S system hardware configuration............................................................................... 23 4.1 IBIS-S Sensor................................................................................................................. 23 4.2 Antennas ........................................................................................................................ 24 4.2.1 Ku band system antennas...............................................................................................24 4.2.2 X band system antennas.................................................................................................27 4.3 Control and acquisition PC........................................................................................... 28 4.4 Batteries......................................................................................................................... 29 4.5 Connection cable kit IBIS-CS KIT................................................................................. 29 4.6 Tripod and three axial head .......................................................................................... 30 5. IBIS-S Installation and Dismantling Procedure................................................................. 31 5.1 Material required........................................................................................................... 31 5.2 IBIS-S installation.......................................................................................................... 33 5.3 Dismantling IBIS-S........................................................................................................ 41 6. Useful Tips.............................................................................................................................. 43 6.1 Installation..................................................................................................................... 43 6.2 Use................................................................................................................................. 44 Appendix A - Restrictions......................................................................................................... 45 Appendix B - Technical Specifications.................................................................................... 45 B.1 - Radar sensor............................................................................................................... 45 B.2 - Batteries / battery charger.......................................................................................... 46 B.3 - Panasonic CF-19 PC.................................................................................................. 46 Appendix C - Elements of Radar Technology ........................................................................ 47 C.1 - Definitions .................................................................................................................. 47 C.1.1 Main antenna lobe .........................................................................................................47
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  13 / 48 All information contained in this document is property of  IDS.  All rights reserved. FIGURES INDEX  FIG. 2.1 – IBIS-S..........................................................................................................................................18 FIG. 3.1 – TRIPOD BAG.............................................................................................................................19 FIG. 3.2 – IBIS-S CASE...............................................................................................................................20 FIG. 4.1 – IBIS-S SENSOR..........................................................................................................................23 FIG. 4.2 – REAR (A) AND FRONT (B) VIEW OF IBIS-S SENSOR ........................................................24 FIG. 4.3 – BOTTOM VIEW IBIS-S SENSOR.............................................................................................24 FIG. 4.4 – IBIS-H20 VERTICAL PLANE PATTERN................................................................................25 FIG. 4.5 – IBIS-H20 HORIZONTAL PLANE PATTERN..........................................................................25 FIG. 4.6 – IBIS-H20 ANTENNA.................................................................................................................25 FIG. 4.7 – IBIS-H23 VERTICAL PLANE PATTERN................................................................................26 FIG. 4.8 – IBIS-H15 HORIZONTAL PLANE PATTERN..........................................................................26 FIG. 4.9 – IBIS-H15 VERTICAL PLANE PATTERN................................................................................26 FIG. 4.10 – IBIS-H15 HORIZONTAL PLANE PATTERN........................................................................26 FIG. 4.11 – IBIS-H13 VERTICAL PLANE PATTERN..............................................................................26 FIG. 4.12 – IBIS-H13 HORIZONTAL PLANE PATTERN........................................................................26 FIG. 4.13 – X BAND ANTENNA VERTICAL PLANE PATTERN ..........................................................27 FIG. 4.14 – X BAND ANTENNA HORIZONTAL PLANE PATTERN ....................................................27 FIG. 4.15 – PC PANASONIC CF-19 ...........................................................................................................28 FIG. 4.16 – CONNECTIONS SCHEME......................................................................................................29 FIG. 5.1 – THE IBIS-S CASE......................................................................................................................31 FIG. 5.2 – CONTENTS OF THE IBIS-S CASE ..........................................................................................32 FIG. 5.3 – SECOND LAYER OF IBIS-S CASE CONTENTS....................................................................32 FIG. 5.4 – INSTALLED TRIPOD................................................................................................................33 FIG. 5.5 – COMPOSITION OF THE TRIAXIAL HEAD ...........................................................................34 FIG. 5.6 – MOUNTED TRIAXIAL HEAD .................................................................................................34 FIG. 5.7 – TRIAXIAL HEAD FIXED TO THE TRIPOD...........................................................................35 FIG. 5.8 – UNBLOCKING THE LEVERS OF THE QUICK LOCK MECHANISM.................................35 FIG. 5.9 – METALLIC NUT........................................................................................................................36 FIG. 5.10 – TIGHTENING NUT .................................................................................................................36 FIG. 5.11 – SENSOR INSTALLATION ONTO THE TRIPOD..................................................................37 FIG. 5.12 – MOUNTING THE OPTICAL TELESCOPE............................................................................37 FIG. 5.13 – MOUNTING THE ANTENNAS ..............................................................................................38 FIG. 5.14 – POINTING THE SENSOR .......................................................................................................38 FIG. 5.15 – REMOVE THE PROTECTION CAPS.....................................................................................39 FIG. 5.16 – CONNECTING THE SENSOR TO THE BATTERY..............................................................39 FIG. 5.17 – INSTALLED IBIS-S SYSTEM ................................................................................................40 FIG. 5.18 – START UP WINDOW OF THE IBIS-S CONTROLLER SOFTWARE .................................40
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  14 / 48 All information contained in this document is property of  IDS.  All rights reserved. FIG. 5.19 – REMOVING THE SENSOR FROM THE THREE AXIAL HEAD ........................................41 FIG. 5.20 – POSITION OF THE BODY OF THE THREE AXIAL HEAD WHEN PACKING IT AWAY42 FIG. 6.1 – PROJECTION OF DISPLACEMENT DATA............................................................................43 FIG. 6.2 – TRIPOD.......................................................................................................................................44  FIG. C. 1 – SCHEMATIC DIAGRAM OF THE ANTENNA BEAM.........................................................47 FIG. C. 2 – AREA OF THE SCENARIO COVERED BY THE ANTENNA BEAM MAIN LOBE ..........48  TABLES INDEX  TAB. 3.1 – TRIPOD BAG CONTENTS......................................................................................................19 TAB. 3.2 – IBIS-S CASE CONTENT..........................................................................................................22 TAB. 4-1 – WIDTH OF THE MAIN LOBES OF THE IBIS-H20 ANTENNAS AT -3 DB AND -10 DB.25 TAB. 4-2 – KU BAND ANTENNAS CHARACTERISTICS .....................................................................27 TAB. 4-3 – WIDTH OF THE MAIN LOBES OF THE X BAND ANTENNAS AT -3 DB AND -10 DB .27
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  15 / 48 All information contained in this document is property of  IDS.  All rights reserved. 1. INTRODUCTION This document provides an introduction to the IBIS-S system (Image By Interferometric Survey-S), with particular reference to the concepts the user must learn before starting to use  this  device.  Therefore  we  recommend  that  you  read  the  entire  document  before starting the system. If technical assistance is required, please use the contact numbers provided on page 3 of this manual.  1.1 Scope  This document will provide the operator with all the necessary knowledge to install and maintain the IBIS-L system. In particular, the manual describes:  - The contents of the cases;  - The procedure for installing and dismantling the system; - Information for the safe use of the system. 1.2 Field of application  This document applies to the installation and dismantling of the of the IBIS system in S configuration and its use in the field for monitoring quasi static or dynamic phenomena.   1.3 Authorisation for use – national restriction European countries IBIS-S system has been classified by the CEPT Administrations as SRD – Short Range Device - i.e.  a  device that doesn’t cause  interference to other systems operating in  the same frequency band. IBIS-S has so been included in the ERC/REC 70-03 which defines the SRD equipment. For Ku band system While the European countries update their national frequency allocation table applying the new recommendations, currently the use of IBIS-S system outside a laboratory can still be subject to authorisation by the Competent Ministry of the country where the system will be used. Please refer to the country’s Competent Ministry to know whether there is the need of an authorisation. For X band system Almost  all  the  European  countries  have  applied  the  ERC/REC  70-03  for  the  X  band system. Please refer to the Competent Ministry of the country where the system will be used to know if there are limitations in the use of X band IBIS-S equipment.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  16 / 48 All information contained in this document is property of  IDS.  All rights reserved.  1.4 CE Marking  This equipment is in compliance with the essential requirements and other relevant provisions of the Directive 1999/5/EC. The full Declaration of Conformity can be found either on the CD or a separate document included with this product.  This is a Class A product. In a domestic environment it may cause radio  interference, in  which  case  the  user  may be  required  to  take adequate measures.   1.5 Acronyms IBIS-S: Image By Interferometric Survey - S; SF-CW: Stepped Frequency - Continuous Wave.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  17 / 48 All information contained in this document is property of  IDS.  All rights reserved. 2. OVERVIEW 2.1 How to use this manual  This manual consists of the following chapters: • Chapter 3 - contents of the cases  • Chapter 4 - IBIS-S system hardware configuration • Chapter 5 - IBIS-S system installation and dismantling procedure • Chapter 6 - Useful Tips • Appendix A - Restrictions • Appendix B - Technical Specifications • Appendix C - Elements of Radar Technology 2.2 General description of the IBIS-S system The  IBIS-S  system  is  designed  to  remotely  measure  displacements  with  a  sampling frequency up to 200 Hz with an accuracy as fine as a hundredth of a millimetre.  The performance of the IBIS-S system depends on the type of configuration used and on the operative measurement conditions; however, the best performance characteristics can be defined as follows: • Maximum operational distance: 1000 m; • Maximum image resolution in distance: 75 cm; • Accuracy in measuring displacements in the viewing direction: 0.01 mm; The time required for instrument installation is about 20 minutes, and the same time is required for its dismantling. The instrument has been specifically designed for outdoor use and is equipped with IP65 level protection and is supplied with a notebook PC specifically designed for outdoor use in extreme conditions. The IBIS-S system offers the following advantages over currently available monitoring systems (GPS, extensometers, accelerometers ): • remote monitoring without the need to access the structure to be monitored • Resolution of 0.75 m which permits IBIS-S to identify a large number of “virtual displacement  sensors”  on  the  area  under  investigation,  simply  by  remotely targeting the scenario; • Acquisition frequency of the entire measurement area up to 200Hz; • Directly measure the displacements in real time: IBIS-S can process acquired data and display the displacement of a point selected from the scenario in real time. This IBIS-S characteristic permits the monitoring of damaged structures with real time generation of alarm signals in case of collapse danger;
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  18 / 48 All information contained in this document is property of  IDS.  All rights reserved. • Displacement  measurement  accuracy  up  to  1/100  of  a  millimetre:  the interferometer  technique  permits  IBIS-S  to  measure  movements  with  a  high degree  of  accuracy  and  precision,  never  seen  before  in  a  remote  monitoring system; • Quick to install; • Functioning conditions suitable for long term monitoring :  Automatic  functioning  (presence  of  an  operator  not  necessary  while functioning);  Can operate night and day;  Can operate in any weather conditions; The  IBIS-S  system is  particularly  suitable  for  all  applications  where  it  is  important to measure displacements of a structure without the need to have direct access to it , or when short investigations must be performed quickly. By  performing  long  range  measurements,  without  the  need  for  direct  contact  with  the structure to be monitored, IBIS-S permits measurements to be performed even when: • The area of interest is not accessible; • The structure is very tall such as a large antenna or a tower; • The structure is covered by paintings or sculptures and it is not feasible to perform contact monitoring. In addition, in emergency situations when monitoring activities are required to guarantee safety,  the  possibility  if  performing  remote  monitoring  may  be  an  essential  condition towards saving lives.   Fig. 2.1 – IBIS-S
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  19 / 48 All information contained in this document is property of  IDS.  All rights reserved. 3. PACK CONTENTS The packing cases contain the following items:  Tripod Bag:   Black shoulder bag with tripod inside: size 20x20x80cm, total weight 6Kg,. (see Tab. 3.1).   Fig. 3.1 – Tripod bag   N°1 tripod Tab. 3.1 – Tripod bag contents
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  20 / 48 All information contained in this document is property of  IDS.  All rights reserved.  IBIS-S case:   Black trolley containing material listed in Tab. 3.2: size 55x30x80 cm, weight  40 kg.  Fig. 3.2 – IBIS-S case     N°1 IBIS sensor  N°1 Optical telescope
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  21 / 48 All information contained in this document is property of  IDS.  All rights reserved.  N°1 pair of antennas with four fixing screws for each  N°1 USB cable to connect IBIS-S sensor to the computer (length: 3m).  N°1 power cable used to connect IBIS-S sensor with the battery (length: 3m).  N°1 three axial support for IBIS-S sensor   N°1 PC PANASONIC CF19  (the original package with warranties and software licences is provided separately)
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  22 / 48 All information contained in this document is property of  IDS.  All rights reserved.  N°2 12V batteries with one yellow bag each  N°1 battery charger  N°1 PC power supplier from electrical network  N°1 PC power supplier from batteries   N°1 IBIS-S user manual N°1 IBIS-S Controller manual Tab. 3.2 – IBIS-S case content
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  23 / 48 All information contained in this document is property of  IDS.  All rights reserved. 4. IBIS-S SYSTEM HARDWARE CONFIGURATION IBIS-S components description is provided in this section of the manual: • Cap.4.1 IBIS-S sensor; • Cap.4.2 IBIS antennas; • Cap.4.3 control and acquisition PC; • Cap.0 power supply batteries IBIS-BAT; • Cap.4.5 power supply cables kit IBIS-C KIT; • Cap.4.6 tripod (IBIS-TR) and three axial head(IBIS-H3). 4.1 IBIS-S Sensor The  IBIS-S  sensor  is  the  unit  containing  all  the  parts  for  the  generation, transmission, reception and acquisition of the radar signal. The sensor (see Fig. 4.1) is a yellow box having 375x270x115 mm dimensions.   Fig. 4.1 – IBIS-S sensor  It features the following interfaces (see Fig. 4.2 and Fig. 4.3): • 1 type A USB Female connector on the rear of the box; • 1 12 pole Male connector to provide power on the rear of the box; • 2 housings for the antennas on the front of the box. • 1 dovetail guide to be used to fix the optical telescope to the sensor (see par.5.2) on the top of the box; • 1 threaded screw hole to permit the sensor to be fitted onto the tripod (see par. 5.2) on the bottom of the box; • 4 dovetail elements to  permit  the sensor to  be  fitted  onto  the  pointing system positioning module (for IBIS-L configuration).
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  24 / 48 All information contained in this document is property of  IDS.  All rights reserved.   (a)   (b) Fig. 4.2 – Rear (a) and front (b) view of IBIS-S sensor   Fig. 4.3 – Bottom view IBIS-S sensor 4.2 Antennas 4.2.1 Ku band system antennas The Ku band IBIS-S system is provided with two identical IBIS-H20 antennas operating in vertical polarisation and characterised by a maximum gain  of  20dBi. The amplitude characteristics of the antenna main lobe at -3 dB and -10 dB are provided in Tab. 4-1 and its vertical and horizontal patterns are shown in Fig. 4.4 and Fig. 4.5. For further details see appendix 6.2C.1 - . USB Dovetail guide housings Power supply 4 dovetail elements for IBIS-L configuration Threaded screw hole
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  25 / 48 All information contained in this document is property of  IDS.  All rights reserved. IBIS-H20 HORIZONTAL PLANE   VERTICAL PLANE   -3 dB  17°  15°  -10 dB  34°  45° Tab. 4-1 – Width of the main lobes of the IBIS-H20 antennas at -3 dB and -10 dB    Fig. 4.4 – IBIS-H20 vertical plane pattern  Fig. 4.5 – IBIS-H20 horizontal plane pattern  The sensor is fitted with two flanges, each with four filleted holes for the installation of the pair of antennas (see paragraph 5.2).  Fig. 4.6 – IBIS-H20 antenna   If desired as an optional or a substitution, the IBIS-H20 antennas can be replaced by a pair of three other antennas whose characteristics are reported below: IBIS-H23 antennas (Type 1) having the following characteristics: • Maximum gain of 23.5 dBi; • Horizontal antenna beam width at -3dB: 11deg. • Vertical antenna beam width at -3dB: 10deg. IBIS-H15 antennas (Type 3) having the following characteristics:  • Maximum gain of 15 dBi; • Horizontal antenna beam width at -3dB: 29deg. V H
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  26 / 48 All information contained in this document is property of  IDS.  All rights reserved. • Vertical antenna beam width at -3dB: 25deg. IBIS-H13 antennas (Type 4) having the following characteristics:  • Maximum gain of 13.5 dBi; • Horizontal antenna beam width at -3dB: 38deg. • Vertical antenna beam width at -3dB: 18deg. Figure  from  Fig.  4.7  to  Fig. 4.12  show  the  vertical and  horizontal  patterns  of  antenna Type 1, 3 and 4 and Tab. 4-2 summarizes the information for the all four antenna types.    Fig. 4.7 – IBIS-H23 vertical plane pattern  Fig. 4.8 – IBIS-H15 horizontal plane pattern   Fig. 4.9 – IBIS-H15 vertical plane pattern  Fig. 4.10 – IBIS-H15 horizontal plane pattern   Fig. 4.11 – IBIS-H13 vertical plane pattern  Fig. 4.12 – IBIS-H13 horizontal plane pattern
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  27 / 48 All information contained in this document is property of  IDS.  All rights reserved. Gain  Elevation  Azimuth  Antenna Type   [dBi] [deg]  [deg] 1 - IBIS-H23       -3 dB azimuth beamwidth  10  11 -10 dB azimuth beamwidth   23,5  30  23        2 - IBISH20       -3 dB azimuth beamwidth  15  17 -10 dB azimuth beamwidth   20  45  34        3 - IBIS-H15       -3 dB azimuth beamwidth  25  29 -10 dB azimuth beamwidth   15  49  53        4 - IBISH13       -3 dB azimuth beamwidth  18  38 -10 dB azimuth beamwidth   13,5  30  70 Tab. 4-2 – Ku band Antennas characteristics  4.2.2 X band system antennas The X band IBIS-S system is provided with two identical antennas operating in vertical polarisation and characterised by a maximum gain of 21dBi. The amplitude characteristics of the antenna main lobe at -3 dB and -10 dB are provided in Tab. 4-3 and its vertical and horizontal patterns are shown in Fig. 4.13 and Fig. 4.14. For further details see appendix 6.2C.1 -  . X band antenna HORIZONTAL PLANE   VERTICAL PLANE   -3 dB  15°  15°  -10 dB  27°  25° Tab. 4-3 – Width of the main lobes of the X band antennas at -3 dB and -10 dB    Fig. 4.13 – X band antenna vertical plane pattern  Fig. 4.14 – X band antenna horizontal plane pattern
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  28 / 48 All information contained in this document is property of  IDS.  All rights reserved. The sensor is fitted with two flanges, each with four filleted holes for the installation of the pair of antennas (see paragraph 5.2).  4.3 Control and acquisition PC The IBIS-S system is supplied with a notebook PC, model PANASONIC CF-19 (see Fig. 4.15). It contains the operative system windows XP and the pre-installed control and data acquisition software IBIS-S Controller v. 02.01.004.   Fig. 4.15 – PC Panasonic CF-19  Characteristics of the supplied model are: • Intel Core Duo Processor U2400; • 100 Mb/s Ethernet card; • RAM 512 MB memory ; • max monitor resolution 1024x768 pixels; • max number of colours 16 777 216 colours; • Windows XP Professional operative system; • HDD 80 GB, shock-proof (mounted on gel support or equivalent); • Protection from atmospheric agents (conforms with IP54); •  No communication software such as Firewall, WiFi or antivirus must be installed to avoid any conflict with the IBIS-S Controller software.  NOTA: IDS takes no responsibility for malfunctioning if there is a functional conflict between its software and any software installed on the notebook PC by the user. IDS does not guarantee  that  the  performance  of  its  equipment  will  be  maintained  using  a configuration different to that recommended.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  29 / 48 All information contained in this document is property of  IDS.  All rights reserved. The  notebook  is  supplied  with  a  network  power  supplier  (220V)  and  a  battery  power supplier (12V). The latter permits to supply the notebook using the  battery or the 12V plug of a car. 4.4 Batteries IBIS-S  is  provided  with  two  12Vdc  batteries  and  with  one  battery  charger  that  can recharge a battery in about 6 hours.  The batteries can be used contemporarily:  • One to supply IBIS-S sensor; • The other to supply the notebook using the battery power supplier. In both cases one battery lasts about 4 hours.. 4.5 Connection cable kit IBIS-CS KIT The IBIS-CS KIT includes: • A 3 m long USB cable to connect IBIS-S sensor to the notebook; • A 3 m long power supply cable to connect IBIS-S sensor to the battery; • Two power supply cable for the notebook:  One to supply it with the battery (12 V);  The other to supply it with the network (220 V 50 Hz).  Fig. 4.16 shows the connections scheme.  Fig. 4.16 – Connections scheme     IBIS-S PC Battery USB IBIS-S  power supply  PC power supply Battery
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  30 / 48 All information contained in this document is property of  IDS.  All rights reserved. 4.6 Tripod and three axial head The IBIS-S standing device is composed of a tripod and a head with three rotational axles. The  IBIS-S  sensor  stands  fixed  on  the  triaxial  head  which  is  screwed  on  the  tripod  providing stable support on the ground. The  triaxial  head  permits  the  operator  to  change  the    IBIS-S  sensor  pointing,  simply acting on the axes blocking levers. The tripod characteristics are listed below: • weight: 4,3kg; • minimum height: 43cm; • maximum height: 188cm  Triaxial head characteristics are listed below: • weight: 1,9 kg; • azimuth allowable rotation: 360°; • elevation allowable rotation: from -25 deg to + 90 deg; • lateral rotation: from -30 deg to +90 deg.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  31 / 48 All information contained in this document is property of  IDS.  All rights reserved. 5. IBIS-S INSTALLATION AND DISMANTLING PROCEDURE  The  IBIS-S  system  has  been  designed  to  be  fast  and  simple  to  install.  The  complete procedure takes about 20 minutes to have the instrument ready for operation. The same time is required to dismantle it. The  following  section  describes  all  the  material  required  (Para.  5.1)  and  the  steps  to follow to correctly install (Para. 5.2) and dismantle(Para. 5.3) IBIS-S.  5.1 Material required The material required for installation includes: • IBIS-S case; • Bag containing tripod; • Small tapered cross slot screwdriver (not supplied).  Proceed as follows to remove the various parts from the case: 1. sit the IBIS-S case on the ground;  Fig. 5.1 – The IBIS-S case  2. open the 7 catches around the IBIS-S case and lift the lid; 3. after removing the protective layer, you will see: a. 2 batteries; b. 1 battery charger; c. 1 three axial head; d. 1 PC power supply converter for battery; e. 1 optical telescope f. 1 USB cable and 1 sensor power supply cable
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  32 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Fig. 5.2 – Contents of the IBIS-S case  4. remove the Panasonic PC, the optical telescope, the USB cable and the sensor power supply cable; 5. you will see the second layer of equipment: a. 1 pair of H20 antennas; b. 1 mains transformer for the PC; c. 1 IBIS-S sensor   Fig. 5.3 – Second layer of IBIS-S case contents Battery charger PC-Sensor USB cable Panasonic PC  Batteries Battery transformer for PC  Three axial head Sensor power supply cable Optical telescope IBIS-S sensor H20 Antennas PC mains transformer
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  33 / 48 All information contained in this document is property of  IDS.  All rights reserved. 5.2  IBIS-S installation In order to simplify system installation, the area where the IBIS-S is to be installed must be chosen carefully. The selected area must satisfy the following requirements: • The scenario of interest must be visible and the view must be uninterrupted by the presence of obstacles from the chosen point (trees, fences, buildings); • The area must be sufficiently large to mount the tripod, manoeuvre with the case and for the operator to work from (the tripod covers at most a circular surface 1.5 m in diameter while the case has a base of 85x55 cm); • The  surface  must  be  compact  and  stable  to  avoid  any  subsidence  under  the weight of the instrument.  Once the optimal installation point has been chosen, proceed as follows: 1. Remove the tripod form its bag. 2. Open the tripod and  fix it at  the desired height using the levers and blocking screws.  3. Ensure that all the joints have been firmly tightened to optimise the rigidity and stability of the tripod. 4. Position the tripod on the ground being careful that the area chosen is stable. 5. Level the tripod using its spirit level, adjusting the length of the individual legs if required  .  Fig. 5.4 – Installed tripod  6. Remove the triaxial head and handles from the case.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  34 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Fig. 5.5 – Composition of the triaxial head   7. Remove the plastic tags from the long handle and the triaxial head. 8. Screw in the two short handles in the yellow coloured nut covers. 9. Screw the long handle into the threaded hole on the side of the triaxial head. 10. Tighten the three handles.  Fig. 5.6 – Mounted triaxial head   11. Screw the triaxial head onto the filleted pin on the top of the tripod; Adjustment handles Hexagonal lock Triaxial head
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  35 / 48 All information contained in this document is property of  IDS.  All rights reserved.   Fig. 5.7 – Triaxial head fixed to the tripod  12. rotate  the  three  axial  head,  working  on  the  three  handles  until  it  perfectly  is levelled with the two spirit levels positioned near the top of the three axial head (ensure that the handles are well tightened). 13. unblock the hexagonal quick lock from the three axial head by acting on the 2 levers as shown in Fig. 5.8.    Fig. 5.8 – Unblocking the levers of the quick lock mechanism   14. Remove the hexagon from the triaxial head and remove the plastic cap covering the hexagon screw. 15. Insert the quick lock hexagon screw into the threaded hole on the bottom of the sensor , working on the metallic nut (Fig. 5.9); Handle for elevation control Handle for azimuth control Handle for horizontal control
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  36 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Fig. 5.9 – Metallic nut  16. Position the hexagon so that one side of the hexagon is parallel with the long side of the IBIS-S head base, then block the hexagon using the tightening nut (Fig. 5.10);  Fig. 5.10 – Tightening nut  17. Lift the sensor with the antenna side pointing forward. 18. Position yourself with the sensor behind the tripod on the side with the elevation control handle. 19. Lift the sensor over the tripod and slowly lower it making sure that the hexagon is positioned above the quick locking mechanism on the triaxial head. 20. Fix the sensor onto the tripod, ensuring the locking mechanism clicks into place.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  37 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Fig. 5.11 – Sensor installation onto the tripod   21. Retrieve the optical telescope and loosen the lower screws. 22. Install the optical telescope on the sensor, sliding it into the guide on the top of the  sensor  and  fix  it  by  tightening  the  screws  (the  writing  on  the  telescope should face the side with the connectors).  Fig. 5.12 – Mounting the optical telescope   23. Retrieve the two antennas and their fixing screws from the case. 24. Mount the two antennas on the sensor (Fig. 5.13) using the screws provided (4 for each antenna). Antenna side Elevation handle Screws for fixing the telescope
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  38 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Fig. 5.13 – Mounting the antennas   25. Acting on the two handles that block the azimuth and elevation axes, rotate the sensor until the optical telescope is pointing to the desired point of the scenario;  Fig. 5.14 – Pointing the sensor  26. Remove the protection caps covering the connectors on the back of the IBIS-S sensor;
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  39 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Fig. 5.15 – Remove the protection caps   27. Retrieve one of the batteries from the case. 28. Connect the power supply cable to the IBIS-S sensor then to the battery.  Fig. 5.16 – Connecting the sensor to the battery  29. Place the PC near the sensor (during operation we recommend using a portable table to sit the PC on). 30. Connect the PC to the second battery using the car transformer. 31. Start up the PC and log in as administrator. 32. Connect the USB cable to the IBIS-S  sensor and then to the PC;
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  40 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Fig. 5.17 – Installed IBIS-S system   33. Start  up  the  IBIS-S  Controller  control  and  management  software  by  double clicking ion the icon shown on the desktop. 34. Check software has recognised the sensor.  Fig. 5.18 – start up window of the IBIS-S Controller Software  Once these operations have been completed, IBIS-S is active and ready to be used. For  the  description of the control  and  management SW  functions,  refer  to the specific manual.  USB cable Battery transforming PC cable
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  41 / 48 All information contained in this document is property of  IDS.  All rights reserved. 5.3 Dismantling IBIS-S 1. Close the IBIS-S Controller application and turn off the PC; 2. Disconnect the power supply cable form the sensor and then from the battery. 3. Disconnect the USB cable from the PC and then from the sensor. 4. Disconnect the transformer from the PC and then from the battery. 5. Screw the protection caps onto the two IBIS-S sensor connectors . 6. Remove the optical telescope from the IBIS-S sensor by loosening the screws and sliding it out of the guide; 7. Remove the two IBIS-H20 antennas from the sensor. 8. Reposition the antennas in the appropriate place in the IBIS-S case. 9. Keeping  firm  hold  of  the  sensor,  unblock  the  quick  lock  mechanism  on  the triaxial head (we recommend this operation is performed by two operators; one keeping hold of the sensor, the other unblocking the quick lock mechanism).    Fig. 5.19 – Removing the sensor from the three axial head  10. Remove the IBIS-S sensor, lifting it off of the triaxial head. 11. Place the sensor on one side and loosen the external fixing nut on the hexagon. 12. Unscrew the hexagon from the bottom of the IBIS-S sensor, acting on the metallic nut and screw on the back of the hexagon on the triaxial head. 13. Replace the IBIS-S sensor in its position in the IBIS-S case. 14. Remove the triaxial head from the tripod by rotating the azimuth control handle anticlockwise (the handle must be securely tightened).
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  42 / 48 All information contained in this document is property of  IDS.  All rights reserved.  Fig. 5.20 – Position of the body of the three axial head when packing it away  15. Close the tripod and place it in its bag. 16. Replace  the  remaining  objects  into  the  IBIS-S  case  (cables,  PC  and  optical telescope). 17. Close the IBIS-S case after having fixed secure all parts. Before closing the case check that the contents are complete and that all the parts have been secured, in order to avoid any damage during transportation.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  43 / 48 All information contained in this document is property of  IDS.  All rights reserved. 6. USEFUL TIPS 6.1 Installation The  successful  performance  of  a  field  measurement  campaign  starts  with  the  initial inspection survey. The scope of this survey is the evaluation of the following aspects: • Identification of a suitable installation point for the IBIS-S  in terms of scenario visibility and stability of the point the equipment will sit on. The characteristics of a good position can be summarised as: o direction of the displacement to be measured coincides with the ideal line traced between the sensor and the measurement point; o there being sufficient space to operate safely and to position the tripod, the IBIS-S case and for the operators to move around; o easily accessible to permit all the required material to be brought to the site. • An  evaluation  beforehand  of  the  quantity,  quality  and  position  of  reflecting points present in the scenario; • The possibility to install artificial reflectors if those present in the scenario are not sufficient. Installation of artificial reflectors eliminates one of the advantages of IBIS-S, because it means that there must be access to the site. However, the use of artificial reflectors allows a better accuracy in displacement measurement and identification of the point the displacement is measured for. • The  presence  of  possible  disturbances  due  to  vegetation,  foliage  or  other sources, near to the intended displacement measurement points. • The number of measurement points and their location in the scenario. The IBIS-S sensor measures displacements along the ideal line joining the sensor to the point being examined (radial displacement), therefore if the real displacement occurs in another direction, the detected displacement must be projected on the basis of geometrical considerations (Fig. 6.1).  Fig. 6.1 – Projection of displacement data   Real displacement  Measured displacement
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  44 / 48 All information contained in this document is property of  IDS.  All rights reserved. To  avoid  making  projection  errors  of  the  displacement  data  and  when  possible,  we  recommend    positioning the sensor  so  that  the  displacement direction of the  interested object occurs along the line that joins the point to the sensor. If this is not possible, in order to minimise projection errors, an accurate georeferencing of the sensor must be performed with respect to the scenario/structure of interest.. Maps of the scenario and /or drawings of the buildings to be observed (in 3D if possible) should be obtained.  If the monitoring concerns a public building or infrastructure , make sure that all required authorisations  have  been  obtained.  It  is  always  a  good  idea  however  to  warn  the responsible local authority before starting to perform measurements. When extending the tripod to  reach the  desired height, the  following basic  precautions should be taken to optimise the rigidity of the structure: • Adjust the height of the structure by first lengthening the middle section of the legs, then the thinner bottom sections; • If possible, avoid extending the central column; • Avoid  opening  the  legs  wide  when  they  have  been  significantly  extended  in length.  Fig. 6.2 – Tripod 6.2 Use When the equipment is functioning, it is a good idea to ensure that nobody can pass or stop in front of the radar sensor to avoid a reduction in the quality of the radar acquisition. When performing a field measurement campaign , it is very useful to have a folding table where the control and acquisition PC can be positioned. Middle section Bottom section Central column Handle for controlling the central column
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  45 / 48 All information contained in this document is property of  IDS.  All rights reserved. APPENDIX A -  RESTRICTIONS A.1 -  Ku band system According to the CEPT Recommendation ERC 70-03 IBIS-L system working at Ku band is allowed to transmit on a band of 200MHz, between 17.1GHz and 17.3 GHz permitting a range resolution up to 0.75m.  A.2 -  X band system According to the CEPT Recommendation ERC 70-03 IBIS-L system working at Ku band is allowed to transmit on a band of 100MHz, between 10.5GHz and 10.6 GHz permitting a range resolution up to 1.5m.   APPENDIX B -  TECHNICAL SPECIFICATIONS B.1 -  Radar sensor Ku band system    Frequency band  17.1 – 17.3 GHz Maximum EIRP power  26dBm X band system    Frequency band  10.5 – 10.6 GHz Maximum EIRP power  27dBm Power supply  9-36 Vdc Power Consumption  average: 27 W  Dimensions  width 375 mm  lenght 270 mm  height 115 mm Weight  10 kg  NOTE: A different configuration of the system is subject to the request of an authorization for use to the competent body of the country where the equipment has to be used. IDS takes no responsibility for the use of the system with a configuration not compliant with the recommendation and without the required permission.
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  46 / 48 All information contained in this document is property of  IDS.  All rights reserved. B.2 -  Batteries / battery charger Batteries:  Voltage supplied  12 Vdc, 12 Ah Autonomy  4 hours (in continuous operation) Dimensions  width 150 mm  length 100 mm  height 100 mm Weight  3.8 kg  Battery charger: Power supply  230 V; 50 Hz Charging time  6 hours  B.3 -  Panasonic CF-19 PC Power supply  16 Vdc Power absorbed  Average: 11 W  Dimensions  Width  270 mm  Length 220 mm  height 55 mm Weight  2.2 kg
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  47 / 48 All information contained in this document is property of  IDS.  All rights reserved. APPENDIX C -  ELEMENTS OF RADAR TECHNOLOGY C.1 -  Definitions C.1.1 Main antenna lobe The term antenna main lobe (or beam) is intended as the angular area within which the antenna concentrates most of the power it is supplied with. The main lobe of an antenna can be schematically represented as a truncated cone with an elliptic base, where the cone vertex is positioned in correspondence with the antenna. The base of the  cone is elliptical  since antennas typically have lobes with different angular amplitudes in the elevation (V) and azimuth (H) planes.    Fig. C. 1 – Schematic diagram of the antenna beam  The following parameters are normally defined to quantify the antenna beam amplitude:   • The beam at -3dB: angular area within which antenna gain is more than 50% of the maximum gain (-3 dB = 10*log10(0,5)). • The  beam  at  -10  by:  angular  area  within  which  gain  is  more  than  10%  of  the maximum gain (-10 dB = 10* log10(0,1)).  From an applicative point of view, this means that the sensor must be pointed so that the scenario  of  interest  falls  inside  the  antenna  beam,  preferably  at  -3dB.  Therefore  the distance at which the instrument should be positioned and its inclination should be chosen depending on the antenna beam being used.  V plane H plane
IDS Ingegneria Dei Sistemi S.p.A.  N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN  48 / 48 All information contained in this document is property of  IDS.  All rights reserved.     Fig. C. 2 – Area of the scenario covered by the antenna beam main lobe  Area visible inside the antenna beam