Confidential   PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 1 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential                K6927            K6731            K6300     Casablanca Wall Control           Hunter Wall Control            THD Wall Control
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 2 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  2  Revision History Revision  Date  Initiator  Description 0.1  16Aug2016  Charles Mckee  Initial Draft 0.2  23Sep2016  Charles Mckee  Updated K6927 ID                                                       Scope:      This  document  establishes  the  performance,  design,  test,  and acceptance requirements for the above Electronic Control Module (ECM).  Any deviations  from  this  specification  must  be  obtained,  in  writing  using  an  ECR (Engineering  Change  Request),  from  the  Supplier.  If  requesting  a  component change  to the  specification,  a sample  of the new component must accompany the request.
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 3 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  3  TABLE OF CONTENTS  I. GENERAL DESCRIPTION  4 II. BENEFITS  4 III.  FUNCTIONAL SPECIFICATIONS  5 V. ELECTRICAL SPECIFICATIONS  7 VI. RF SPECIFICATIONS  9 VIII. REGULATORY SPECIFICATIONS  13 IX.  ENVIRONMENTAL SPECIFICATIONS  13 X. QUALITY  13 XI. DESIGN TEST REQUIREMENTS  15 XII. FACTORY TEST REQUIREMENTS  15 XIII. WARRANTY PERIOD  15 XIV. SAFETY  16 XV. PACKAGING  16 XVI. ENGINEERING CHANGES  17 XVII. CRITICAL COMPONENTS  17 XVIII. REFERENCE DOCUMENTS  18
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 4 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  4  I.  General Description  The  2017  Wall  Controls  are  7-button  remote  controls  intended  for  use  with platform  ECMs  (generation  1.9  and  2.0).  These  wall  controls  have  a  mains disconnect connect switch incorporated and are intended to take the place of the fan’s main power switch.   Assembly #  Description  Features  Power Source K6927  Casablanca Wall Control Fan Speed Control, Fan Direction Control, Light Control, Light Dimming, Pair Toggle, WiFi Reset, Main Power Disconnect Switch (2) DC 1.5V AAA Battery K6731  Hunter Wall Control K6300  THD Wall Control  II.  Benefits  The  key  feature  of  the  2017  wall  control  lineup  is  the  incorporated  mains disconnect switch, which allows this remote to be used in place of the fan’s main power  switch.  The  functional  features  of  these  remote  controls  are  compatible current platform ECMs (generation 1.9 and 2.0). The WiFi Reset function adds accommodation for fans with WiFi functionality. The use of Fan Speed Increase and Decrease functions allow these remotes to be used with multiple fan speed configuration  (3speed,  4sped,  or  BLDC).  Fan  direction  redundancy  has  been added into the feature set with the Updraft and Downdraft commands in addition to  the  standard  reverse  command.  New  Light  Maximum  and  Light  Minimum features have been added as well.
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 5 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  5  III. Functional Specifications A.  SIMPLEconnect Handheld Remotes (Hunter and Casablanca): 1. Fan Control – There will be 3 buttons on the remote that can be used to control the functions of the fan. a)  FAN TOGGLE Function: A press/release of the FAN “” button will toggle the fan state between OFF and ON (last state). b)  FAN INCREASE Function: A press/release of the FAN UP “▲” button will increment the fan speed. There are some special conditions outlined as follows: (1) If the fan is HIGH, pressing the FAN UP “▲” button will not change the fan state and it will remain HIGH.  (2) Holding the FAN UP “▲” button will change the fan state to HIGH (MAX SPEED). c)  FAN DECREASE: A press/release of the FAN DOWN “▼” button will decrement the fan speed. There are some special conditions outlined as follows: (1) If the fan is LOW, pressing the FAN DOWN “▼” button will turn the fan OFF.  (2) IF the fan is OFF, pressing the FAN DOWN “▼” button will not change the fan state and it will remain OFF. (3) Holding the FAN DOWN “▼” button will change the fan state to LOW (SPEED 1). d)  FAN REVERSE Function: A long hold of the FAN “” button on the remote will reverse the direction of the fan. e)  FAN CLOCKWISE Function: A long hold of both the FAN “” and FAN UP “▲” buttons will change the direction of the fan to clockwise (Updraft). If the fan is already in updraft, then there will be no change.
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 6 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  6  f)  FAN COUNTER CLOCKWISE Function: A long hold of both the FAN “” and FAN DOWN “▼” buttons will change the direction of the fan to counterclockwise (downdraft). If the fan is already in downdraft, then there will be no change. 2. Lighting Control – There will be 3 buttons on the remote that can be used to control the functions of the light.  a)  LIGHT TOGGLE Function: A press/release of the LIGHT “” button will toggle the light state between OFF and ON (last state). b)  LIGHT DIM INFINITE Function – A long hold of the LIGHT “” button will initiate the sinusoidal dimming function. There are some special conditions outlined as follows: (1) If the light is OFF or at minimum light output, this function will illuminate the light until the button is released or maximum illumination is reached.  (2) If the light is in any state besides OFF or minimum illumination, this function will begin dimming the light. When the light reaches minimum illumination, it will begin illuminating until the button is released or the maximum light output is reached. c)  LIGHT INCREASE Function: A press/release of the LIGHT UP “▲” button will increment the light intensity. There are some special conditions outlined as follows: (1) If the light is at full intensity, pressing the LIGHT UP “▲” button will not change the light state and it will remain and full intensity.  (2) Holding the LIGHT UP “▲” button will change the light to full intensity (LIGHT MAX). d)  LIGHT DECREASE: A press/release of the LIGHT DOWN “▼” button will decrement the light intensity. There are some special conditions outlined as follows: (1) If the light is at its lowest intensity, pressing the FAN DOWN “▼” button will turn the light OFF.
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 7 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  7  (2) IF the light is OFF, pressing the FAN DOWN “▼” button will not change the light state and it will remain OFF. (3) Holding the LIGHT DOWN “▼” button will change the light state to the lowest intensity (LIGHT MIN). e)  DIMMING MODE TOGGLE Function – A long hold of both the LIGHT DOWN “▼” and LIGHT UP “▲” buttons will toggle the lighting mode between ON/OFF and DIMMING. 3. PAIR TOGGLE Function – A long hold of both the FAN “” and LIGHT “” button will send the PAIR TOGGLE command. If the remote and ECM were previously unpaired, they will become paired. If the remote and ECM were previously paired, they will become unpaired. 4. WiFi RESET function – A long hold of the both the FAN DOWN “▼” and FAN UP “▲” buttons will send the WiFi reset command. IV. Electrical Specifications A.  Power Supply: (2) DC 1.5V AAA Battery B.  PCB Assembly Design:
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 8 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  8
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 9 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  9  V. RF Specifications A.  The operating RF (Radio Frequency) for the Handheld Remote is 433MHz. B.  The following transmission range for handheld remote & wall control is: 1. Receiver located on bench in the lab >100 ft. 2. Receiver assembled in ceiling fan > 75 ft. The remote controls transmission circuit uses a SAW (Surface Acoustic Wave) resonator or an equivalent RF Digital IC.
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 10 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  10   VI. Mechanical Specifications A.  K6972 Casablanca Wall Control 1.  K6927 Assembly Exploded View  2. K6972 Industrial Design
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 11 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  11   B.  K6731 Hunter Wall Control 1. K6731 Assembly Exploded View                2. K6731 Industrial Design
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 12 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  12   C.  K6300 THD Wall Control 1. K6300 Assembly Exploded View                 2. K6300 Industrial Design
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 13 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  13   VII.  Regulatory Specifications  A.  Units must conform to UL 991 and UL244A as required. B.  FCC part 15 C.  IEC 60730-1 Automatic Electrical Controls – General Requirements D.  EMC Performance  IEC 61000-4-2, Electrostatic Discharge Immunity (ESD) •  +/- 8KV direct contact •  +/- 15KV air discharge  IEC 61000-4-3, Radiated radio-frequency electromagnetic field immunity •  Minimum test level of 2 (3V/m) •  90-5000 MHz •  80% AM at 1kHz Sine Wave  IEC 61000-4-6, Conducted disturbances immunity, induced by radio-frequency fields •  Minimum test level of 2 (3V/m) •  90-5000 MHz •  80% AM at 1kHz Sine Wave  IEC 60730-1-H.26, Electromagnetic compatibility (EMC) requirements – Immunity VIII.  Environmental Specifications A.  Operating  Conditions: 0ºC to 85ºC for electrical components inside  the fan or control switch housing.  A 95% RH must be maintained as well. Note: The receiver must withstand temperatures up to 85ºC, but the remote has a requirement of 70ºC.  B.  Storage: -40ºC to 70ºC for handheld remote. C.  Storage: -40ºC to 85ºC for receiver. D.  All electronic components must be rated at -40o to 85o C at least. All Receivers’ PCBA must be Damp Rated. IX. Quality
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 14 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  14   A.  The development of this product must adhere to the latest revision of the Hunter Fan Company Control Product Approval Plan. B.  Quality Parameters: All products must be fit for function. Any deviations from the Product Specification will be considered a defect and will cause rejection of the product by Hunter Fan Company. First Article Inspection reports must be submitted to Hunter Fan for all parts & tools. A complete first article packaged unit is to be accepted by Hunter Fan Engineering & Quality and archived. C.  Product life expectancy is 3 years, based on 8,000 hours usage per year. D.  Quality Inspection: The product must comply with the requirements in the previous  sections  and  will  be  checked  by  the  Standard  Audit Procedure  for  Controls  supplied  by  Hunter  Fan  Company  Quality. Hunter  Fan Company Engineering and Quality may amend the procedure at any time. E.  Cosmetics: The product must meet the Hunter Fan Company Aesthetic Requirements document QA-AR. F.  Workmanship: All  parts  must  meet  the  latest  revision  of  IPC-A-610, "Acceptability of Electronic Assemblies". G.  Packaging: Hunter F4045, Packaging Construction. H.  Performance: Any deviation from these requirements is considered a critical defect and will require immediate corrective action. I.  Drawings: All piece parts used in the manufacturing of the product must meet the dimensions and the specifications outlined on their respective piece part drawings.  A set of drawings must also be kept at Hunter Fan Company.  All drawings must include material and applicable performance specifications for the given part. All information must be included in English and dimensioning units and tolerances must be clearly shown on the drawings. J.  Literature: All instructions, warranty cards and other literature must be legible, complete, in place and free of blemishes, tears, color mismatch, blank pages, wrinkles and contamination. K.  Reliability:  The  packaged  product  must  meet the  International  Safe Transit Association Transportation Test. L.  Material Certification:  Vendor  must  supply  a  Material Certification  of Compliance for all critical components. Components cannot deviate from design without approval of Hunter Fan Company.
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 15 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  15   X.  Design Test Requirements A.  Life Testing:   1. ALT (Accelerated Life Testing) a)  A sample size of 30 units must be subjected to the following test conditions for a total of 5 weeks:  (1) 5ºC / R.H.40% +/- 5% for 1 hour (2) Ramp/transition to 85ºC / R.H. 90% for 1 hour (3) 85 ºC / R.H. 90% +/- 5% for 10 hours (4) Ramp/transition to 5 ºC / R.H. 40% for 1 hour (5) Repeat steps until 5 week duration is complete. 2. HALT (Highly Accelerated Life Testing) a)  A sample size of 5 units each must be subjected to the following tests:  (1) Cold Thermal Step Stress: -20ºC (-4ºF) (2) Hold Thermal Step Stress: >+110ºC (+230ºF) (3) Rapid Thermal Transition: 35 Grms (Gravity Root Mean Squared) (4) Vibration Step Stress: 45 Grms (5) Combined  Environment:  5  rapid  temperature cycles  from  -20ºC  to  110ºC  combined  with  vibration ranging from 7 ~ 35Grms.         XI. Factory Test Requirements  According to R&D-20, section III.  XII.  Warranty Period  One Year
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 16 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  16   XIII.  Safety A.  Agency Requirements: All units must  conform to  the appropriate agency requirements for intended country of sale. Agency requirements are specific to both the product in question and the country where it is sold. Products intended for commercial or industrial use must conform  to country and universal safety standards where applicable. B.  Where applicable, this product must conform to the Hunter General Control Specification F4049. XIV.  Packaging A.  K6972 Casablanca Wall Control (Pack In/ Bulk)  1. Bulk Packer per Current Standards a)  K6931 Casablanca Wall Control Assembly (1) Paired to the ECM in Factory B.  99195 Casablanca Wall Control (Accessory)  1. Packaging TBD a)  K6930 Casablanca Wall Control Accessory Assembly C.  K6731 Hunter Wall Control (Pack In/ Bulk)  1. Bulk Packer per Current Standards a)  K6811 Hunter Wall Control Bulk Assembly (1) Paired to the ECM in Factory D.  99375 Hunter Wall Control (Accessory)  1. Clamshell Packaging per Current Standards a)  K6732 Hunter Wall Control Accessory Assembly (1) Paired to the ECM in Factory E.  99373 THD Wall Control (Accessory)
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 17 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  17   1. Clamshell Packaging per Current Standards a)  K6672-01 THD Wall Control Assembly (1) Paired to the ECM in Factory F.  Physical  Packaging:  The  physical  design  of  the  internal  packaging,  external dimensions, and materials are to be designed by the vendor and approved by Hunter Fan Engineering. Any packaging artwork is to be supplied by Hunter Fan Company. G.  Pallet Stack Requirement: Per Marketing instructions. H.  Markings and Labels: All markings must be either permanently ink stamped, silk-screened, or provided on a UL- recognized material and labeling system preprinted or die-stamped foil type suitable for application to the surface involved, rated 60ºC. 1. Unit model label includes: a)  Hunter name, logo and address  b)  Part number c)  Country of origin  d)  Supplier code 2. Date code: WWYY. The date code must be located in a clearly visible location. XV.  Engineering Changes  Any changes need to be requested according to the latest revision of Hunter Fan Company engineering document QA R&D-5 for ECRs.  XVI.  Critical Components A.  FR4 PCB or higher CTI B. DC 1.5V AAA Batteries C.  Tactile Switches
Confidential     PRODUCT SPECIFICATION 2017 Wall Controls  Rev. 0.2     23Sep2016 Page 18 of 18  Models: K6927, K6731, K6300  Written by: Charles Mckee  Hunter Fan Company Confidential  18   D.  Crystal E.  ASIC (AyDeeKay Heimdall Slave) F.  Battery Holder and Wire Leads G.  120V Switch H.  LEDs  XVII. Reference Documents A.  Hunter General Control Specification F4049 B.  Hunter R&D-22 Electronic Fan Control NPD Procedure Rev 0 C.  Hunter R&D-20 test procedure D.  Test Request Form F4086 E.  Standard Audit Procedure, QA-FG F.  National Safe Transit Association Drop Test G.  ETL/UL/FCC/IC Certification Reports, to be completed by Hunter H.  Artwork, to be completed by Hunter Fan Company I.  UL and C-UL Std. 1917. J.  Hunter Fan Company PAP R&D-9 K.  Hunter Fan Company Aesthetic Requirements document QA-AR  L.  Hunter Fan Company QA R&D-5 M. EMC Performance, Latest IEC 61000 Standards N.  IEC 60730-1 Automatic Electrical Controls International Standard

Navigation menu