Honeywell LXE-MX7T Wireless Handheld Terminal User Manual MX7 Tecton CE User Guide

Honeywell International, Inc. Wireless Handheld Terminal MX7 Tecton CE User Guide

Manual

Draft07-For review only - Do not publish or distribute - LXE ConfidentialMX7 Tecton CE User GuideMicrosoft® Windows® Embedded CE 6 Operating SystemE-EQ-MX7CEOGWW-A2010 Copyright© by LXE®, Inc, An EMS Technologies Company. All RightsReserved.
NoticesLXE Inc. reserves the right to make improvements or changes to published MX7 Tecton information at any time without notice.While reasonable efforts have been made in the preparation of this publication to assure its accuracy, LXE assumes no liabilityresulting from any errors or omissions in this publication, or from the use of the information contained herein. Further, LXEIncorporated, reserves the right to revise this publication and to make changes to it from time to time without any obligation tonotify any person or organization of such revision or changes.TrademarksCopyright © 2010 by LXE Inc., An EMS Technologies Company, 125 Technology Parkway, Norcross, GA 30092 U.S.A. (770)447-4224LXE® and Spire® are registered trademarks of LXE Inc.Microsoft®, ActiveSync®, MSN, Outlook®, Windows®, Windows Mobile®, the Windows logo, and Windows Media areeither registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.Intel and Intel XScale are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States andother countries.Summit Data Communications, Inc. Summit Data Communications, the Summit logo, and “The Pinnacle of Performance” aretrademarks of Summit Data Communications, Inc.The Bluetooth® word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by LXE, Inc. is underlicense.PowerScan is a registered trademark of Datalogic Scanning, Inc., located in Eugene, OR.Symbol® is a registered trademark of Symbol Technologies. MOTOROLA® and the Stylized M Logo are registeredtrademarks of Motorola®, Inc.Hand Held® is a registered trademark of Hand Held Products, Inc., located in Skaneateles Falls, NY.When any part of this publication is in PDF format: “Acrobat ® Reader Copyright © 2010 Adobe Systems Incorporated. Allrights reserved. Adobe, the Adobe logo, Acrobat, and the Acrobat logo are trademarks of Adobe Systems Incorporated”applies.Other product names mentioned within this publication may be trademarks or registered trademarks of other companies.
Table of ContentsSet Up A New MX7 Tecton 1Hardware Setup 1Software Setup 1Laser Warnings and Labels 2Label Location 2Label 2Components 3I/O Port and Cables 4Scanner / Imager Aperture 5Handle 6Handstrap 6Keypads 7Batteries 9How To Connect or Remove the Battery Pack 9Insert/Replace Battery 9Remove Battery 10Hotswap the Main Battery 10Charge or Recharge the Main Battery 11Tapping the Touchscreen with a Stylus 12Backlights and Indicators 13System Status LED 13Alpha mode Status LED 13Scan Status 13Toggle Vibrate Indicator 13Connecting Cables to the MX7 Tecton 14Connecting the USB Client and Power Cable 14Client Cable Assembly 14Connecting the Serial and Power Cable 15Serial/Power Cable Assembly 15Connecting an External Power Supply 16Connecting Vehicle Power 17DC to DC Power Supply Installation 17Connecting Electrical Cables to Power Sources 17Wiring Schematic 18How To Connect Vehicle Electrical Connection 18Vehicle 12V Bare Wire Adapter 20Vehicle Cable Connection Cable (Fuse Not Shown) 20E-EQ-MX7CEOGWW-ADraft 07 [ i ] MX7 Tecton CE User Guide
Table of ContentsFor review only - Do not publish or distribute - LXE Confidential - Draft 07Connecting the Power Cable to the Vehicle 21Connect Power Supply to Vehicle Cradle 23Cradle Power Connector Port 23Connecting the Headset Cable 24Adjust Headset / Microphone and Secure Cable 25Attaching the Handstrap 26Attaching the Trigger Handle 27Assemble the Carry Case 28Carry Case with Metal Snaps 28Set Date and Time Zone 29Using the Input Panel / Virtual Keyboard 29Set Power Scheme Timers 30Battery Power Scheme 30AC Power Scheme 30Set Speaker Volume 31Using the Keypad 31Using the Control Panel 31Touchscreen 32Calibrating the Touchscreen 32Adjusting the Display Backlight Timer 32Apply the Touchscreen Protective Film 32Cleaning the Touchscreen and Scanner Aperture 33Setup Terminal Emulation Parameters 33Using the AppLock Switchpad 34Using the Keypad 34Using the Touchscreen 34Connecting Bluetooth Devices 35Taskbar Connection Indicator 35Reboot Sequences 36Suspend / Resume 36Warmboot 36Troubleshooting 37Continuous Scan Mode 37Regulatory Notices and Safety Information 38Class B Digital Device 38RF Notices 39Laser Light Safety Statement 40Vehicle Power Supply Connection Safety Statement 42Revision History 42E-EQ-MX7CEOGWW-ADraft 07 [ ii ] MX7 Tecton CE User Guide
Table of ContentsFor review only - Do not publish or distribute - LXE Confidential - Draft 07Index 43E-EQ-MX7CEOGWW-ADraft 07 [ iii ] MX7 Tecton CE User Guide
Set Up A New MX7 TectonNote: LXE recommends that installation or removal of accessories be performed on a clean, well-lit surface. Whennecessary, protect the work surface, the MX7 Tecton, and components from electrostatic discharge.While the MX7 Tecton is in a Hazardous Location DO NOT:lConnect an external power source to the MX7 Tecton.lConnect a USB device or audio jack to the MX7 Tecton.lRemove or install a battery pack in the MX7 Tecton.lPlace the MX7 Tecton in a powered dock or cradle.Hardware Setup1. Connect accessories.2. Connect cables.3. Insert/connect a fully charged battery4. Press the Power key.Software SetupPrerequisite: Hardware setup is complete.1. Calibrate Touch screen2. Set Date and Time Zone3. Set Power Schemes Timers4. Set Speaker Volume5. Pair Bluetooth devices6. Setup Wireless client parameters7. Setup terminal emulation parameters8. Setup the LXE AppLock parameters9. Set the LXE DCWedge parametersPlease refer to the MX7 Tecton Reference Guide for further information and instruction.End User License Agreement (EULA)When a new MX7 Tecton starts up a EULA is displayed on the touchscreen. It remains on the screen until the Accept orDecline button is tapped with a stylus.Tap the Accept button to accept the EULA terms and the MX7 Tecton continues the startup process. The EULA is notpresented to the user again.Tap the Decline button to decline the EULA and the MX7 Tecton will reboot. It will continue to reboot until the Accept button istapped with the stylus.Note: The EULA will be presented after any operating system upgrade or re-installation, including language-specificoperating systems.E-EQ-MX7CEOGWW-ADraft 07 [ 1 ] MX7 Tecton CE User Guide
Laser Warnings and LabelsFor review only - Do not publish or distribute - LXE Confidential - Draft 07Laser Warnings and LabelslDo not look into the laser’s lens.lDo not stare directly into the laser beam.lDo not remove the laser caution labels from the MX7 Tecton.lDo not connect the laser barcode aperture to any other device. The laser barcode aperture is certified for use with theMX7 Tecton only.CautionLaser radiation when open. Please read the caution labels. Use of controls, adjustments or performance of pro-cedures other than those specified herein may result in hazardous radiation exposure.Label LocationLabelE-EQ-MX7CEOGWW-ADraft 07 [ 2 ] MX7 Tecton CE User Guide
ComponentsFor review only - Do not publish or distribute - LXE Confidential - Draft 07ComponentsFront1. Scanner/Imager Aperture2. Speaker3. System Status LED4. Scan Button5. Orange Key (Sticky Key)6. Blue Key (Sticky Key)7. Scan Status LED8. Cable Port9. On / Off Button10. Alpha Lock LED (32-Key only)Diamond KeysE-EQ-MX7CEOGWW-ADraft 07 [ 3 ] MX7 Tecton CE User Guide
I/O Port and CablesFor review only - Do not publish or distribute - LXE Confidential - Draft 07Back1. Scanner/Imager Aperture2. Stylus and Stylus Pocket3. Trigger Handle Attach Points4. Main Battery5. Battery Fastener6. Cable PortI/O Port and CablesI/O PortCable: Multipurpose RS-232 and PowerMX7055CABLEE-EQ-MX7CEOGWW-ADraft 07 [ 4 ] MX7 Tecton CE User Guide
Scanner / Imager ApertureFor review only - Do not publish or distribute - LXE Confidential - Draft 07Cable: Multipurpose USB and PowerMX7052CABLEAdapter/Cable : AudioMX7060CABLEAdapter: RS-232 PC port to D9 maleMX7058CABLEScanner / Imager Aperture1. Scanner / Imager Aperture2. MX7 Tecton FrontCaution: Never stare directly into the beam aperture.If Continuous Scan Mode has been enabled (default is disabled), the laser is always on and decoding. Caution: Laser beamis emitted continuously. Do not stare into the laser beam.E-EQ-MX7CEOGWW-ADraft 07 [ 5 ] MX7 Tecton CE User Guide
HandleFor review only - Do not publish or distribute - LXE Confidential - Draft 07Handle1. Imager / Scanner Aperture2. Trigger3. Handle4. Tether Attach PointHandstrap1. Handstrap2. Handstrap Retainer Bracket and mounting screws3. Handstrap ClipE-EQ-MX7CEOGWW-ADraft 07 [ 6 ] MX7 Tecton CE User Guide
KeypadsFor review only - Do not publish or distribute - LXE Confidential - Draft 07Keypads55 Key Delete Primary ANSI Keypad1. System Status LED2. Volume Control Icon3. Display Brightness Icon4. Diamond Key5. Scan Button6. Enter Key7. Orange Key (Sticky Key)8. Blue Key (Sticky Key)9. On Off Button10. Scan Status LEDSpc and Del key location55 Key Backspace Primary ANSI Keypad1. System Status LED2. Volume Control Icon3. Display Brightness Icon4. Diamond Key5. Scan Button6. Enter Key7. Orange Key (Sticky Key)8. Blue Key (Sticky Key)9. On Off Button10. Scan Status LEDSpc and Bksp key locationE-EQ-MX7CEOGWW-ADraft 07 [ 7 ] MX7 Tecton CE User Guide
KeypadsFor review only - Do not publish or distribute - LXE Confidential - Draft 0732 Key Numeric-Alpha Keypad1. System Status LED2. Alpha Status LED3. Diamond Keys4. Scan Button5. Enter Key6. Alph Key7. Orange Key (Sticky Key)8. Blue Key (Sticky Key)9. On Off Button10. Scan Status LEDE-EQ-MX7CEOGWW-ADraft 07 [ 8 ] MX7 Tecton CE User Guide
BatteriesFor review only - Do not publish or distribute - LXE Confidential - Draft 07BatteriesHow To Connect or Remove the Battery PackWarning: Never remove or replace any battery in a hazardous location.The MX7 Tecton will not function unless the battery pack is in place and securely latched.Be sure to place the unit in Suspend Mode (by pressing the Power key or tapping Start | Suspend) before removing the battery.Failing to properly place the device in Suspend mode will result in a loss of all unsaved data.An MX7 Tecton will retain data, while the main battery is removed and replaced with a fully charged main battery, for 5 minutes.Important: When the internal battery power is Low or Very Low connect the AC adapter to the MX7 Tecton before replacing themain battery.Note: The battery should not be replaced in a dirty, harsh or hazardous environment. When the battery is not connected tothe MX7 Tecton, any dust or moisture that enters the battery well or connector may transfer to the battery/well terminals,potentially causing damage.Warning:Only useLXEMX7A380BATT / 159904-0001 or a Low Temperature (CS) Battery : MX7A381BATT (Blue label)batteries as replacements.Insert/Replace BatteryTo insert the main battery, complete the following steps:1. Detach the bottom hook of the handstrap (if installed).2. Tilt the end (without the latch) of the fully charged battery pack into the upper end of the battery compartment, and firmlypress the other end until it is fully inserted into the battery compartment3. Push down on the battery until the retaining clip clicks into place.4. Replace the handstrap clip in its holder (if installed).The MX7 Tecton draws power from the battery immediately upon successful connection.E-EQ-MX7CEOGWW-ADraft 07 [ 9 ] MX7 Tecton CE User Guide
Remove BatteryFor review only - Do not publish or distribute - LXE Confidential - Draft 07Remove BatteryTo remove the battery, complete the following steps:1. Place the MX7 Tecton in Suspend mode.2. Detach the bottom hook of the handstrap (if installed).3. Slide the battery retaining clip down to release the main battery.4. Pull the battery up and out of the battery well.Place the discharged battery pack in a powered battery charger.Hotswap the Main BatteryWarning: Never replace (hotswap) the MX7 Tecton battery in a hazardous location.Place the MX7 Tecton in Suspend Mode. LXE recommends any work in progress be saved prior to replacing the battery pack.Simply replace the discharged battery with a fully-charged battery. An MX7 Tecton, with a fully charged internal battery, willretain data during a battery hotswap for 5 minutes.E-EQ-MX7CEOGWW-ADraft 07 [ 10 ] MX7 Tecton CE User Guide
Charge or Recharge the Main BatteryFor review only - Do not publish or distribute - LXE Confidential - Draft 07Charge or Recharge the Main BatteryWarning:Only useLXEMX7A380BATT / 159904-0001 or a Low Temperature (CS) Battery : MX7A381BATT (Blue label)batteries as replacements.Note: The MX7 Tecton Multi-Charger is designed for an indoor, protected environment. It is not authorized for use inareas designated as Hazardous Locations.New batteries must be fully charged prior to use.The main battery can be recharged in an AC powered Multi-Charger after the battery has been removed from the MX7 Tecton orits packing material when new.The main battery while in the MX7 Tecton can be recharged using several different methods.Note: An external power source is required before the main battery in the MX7 Tecton will recharge.The main battery can be recharged while it is in the MX7 Tecton:lby connecting the MX7 Tecton AC power adapter to the I/O connector at the base of the MX7 Tecton.lby docking the MX7 Tecton in a powered desk cradlelby docking the MX7 Tecton in a powered vehicle cradlelor by connecting the car power adapter (CLA) to the I/O connector at the base of the MX7 Tecton.Note: An uninterrupted external power source (wall AC adapters) transfers power to the computer’s internal chargingcircuitry which, in turn, recharges the main battery and internal battery. Frequent connection to an external power source,if feasible, is recommended to maintain internal battery charge status as the internal battery cannot be recharged by adead or missing main battery.E-EQ-MX7CEOGWW-ADraft 07 [ 11 ] MX7 Tecton CE User Guide
Tapping the Touchscreen with a StylusFor review only - Do not publish or distribute - LXE Confidential - Draft 07Tapping the Touchscreen with a StylusNote: Always use the point of the stylus for tapping or making strokes on the touchscreen.Never use an actual pen, pencil, or sharp/abrasive object to write on the touchscreen.Hold the stylus as if it were a pen or pencil. Touch an element on the screen with the tip of the stylus then remove the stylusfrom the screen.Firmly press the stylus into the stylus holder when the stylus is not in use.Using a stylus is similar to moving the mouse pointer then left-clicking icons on a desktop computer screen.Using the stylus to tap icons on the touchscreen is the basic action that can:lOpen applicationslChoose menu commandslSelect options in dialog boxes or drop-down boxeslDrag the slider in a scroll barlSelect text by dragging the stylus across the textlPlace the cursor in a text box prior to typing in datalPlace the cursor in a text box prior to retrieving data using the scanner/imager or an input/output device connected to theserial port.A stylus replacement kit is available.E-EQ-MX7CEOGWW-ADraft 07 [ 12 ] MX7 Tecton CE User Guide
Backlights and IndicatorsFor review only - Do not publish or distribute - LXE Confidential - Draft 07Backlights and IndicatorsThe MX7 Tecton System Status LED is located at the top left of the keypad, below the F3 key. The Alpha Mode LED is locatedbelow the F4 key on the 32-key keypad.LEDs (Light Emitting Diodes) are located on the front of the MX7 Tecton. They are:1. System Status LED indicates power management status.2. Alpha Mode Status LED applies to the 32-key keypad only.System Status LEDBlinking Red Battery power fail; critical suspend modeSteady Red Main battery lowBlinking Green Display turned offYellow / Amber A few seconds when Power key is pressedNo Color No user intervention required.Alpha mode Status LEDSteady Green Device is in “Alpha” character input modeNo Color Device is in “Numeric” key input modeScan StatusAn oval indicator situated below the keypad and next to the On button.Steady Green Good scanSteady Amber Decoder engine storing changed parametersSteady Red Scan in progressNo Color Scanner / Imager ready for use or no scanner installed.Toggle Vibrate IndicatorStart | Settings | Control Panel | Data Collection| Notification tabThe MX7 Tecton vibration motor is activated when a scan is completed successfully (good scan vibration) or with a failure(scan key released before good scan, timeout, or rejected because of Data Options configuration).The vibrations can be detected under the handstrap or through the trigger handle.Toggle the vibrate indicator on or off by tapping the desired radio button for Good Scan Vibration and Bad Scan Vibration.Options are:lOfflShortlMediumlLongE-EQ-MX7CEOGWW-ADraft 07 [ 13 ] MX7 Tecton CE User Guide
Connecting Cables to the MX7 TectonFor review only - Do not publish or distribute - LXE Confidential - Draft 07Connecting Cables to the MX7 TectonNote: Do not connect or disconnect cables in a Hazardous location.Connecting the USB Client and Power CablePrerequisite : AC/DC Adapter AssembledNote: Do not connect AC power to the AC Adapter yet.Client Cable Assembly1. Holding the cable I/O connector, pinch the catch release buttons in until the catches are open. Connect the cable to theMX7 Tecton I/O port by matching the shape of the I/O connector on the cable with the shape of the I/O connector at thebase of the MX7 Tecton. Release the catch release buttons.2. Insert the AC adapter single pin cable .3. Connect the AC Adapter to a power source (wall outlet).4. Insert the USB client plug into the target USB Client port.The MX7 Tecton and the USB client are connected.E-EQ-MX7CEOGWW-ADraft 07 [ 14 ] MX7 Tecton CE User Guide
Connecting the Serial and Power CableFor review only - Do not publish or distribute - LXE Confidential - Draft 07Connecting the Serial and Power CablePrerequisite : AC/DC Adapter, AssembledNote: Do not connect AC power to the AC Adapter yet.Serial/Power Cable Assembly1. Holding the cable I/O connector, squeeze the catch release buttons in until the catches are open. Connect the cable tothe MX7 Tecton I/O port by matching the shape of the I/O connector on the cable with the shape of the I/O connector atthe base of the MX7 Tecton. Release the catch release buttons.2. Connect the AC adapter single pin cable .3. Connect the assembled AC/DC Adapter to a power source (wall outlet).4. Connect the RS-232 cable end to the desired serial device. Turn the thumbscrews clockwise until the connection isfinger-tight.The MX7 Tecton and the serial device are connected.E-EQ-MX7CEOGWW-ADraft 07 [ 15 ] MX7 Tecton CE User Guide
Connecting an External Power SupplyFor review only - Do not publish or distribute - LXE Confidential - Draft 07Connecting an External Power Supply1. Connects to AC single-pin cable end2. AC receptacle3. Wall plug4. AC connection from wall to adapterTo apply external power to the MX7 Tecton follow the steps below in sequence.1. Plug the 3 prong AC adapter cable end of the external power assembly into an AC power source (e.g. wall outlet).2. Firmly press the female end of the power cable into the male connector on the power adapter. When AC power is beingsupplied to the power adapter, the LED on the power adapter illuminates green.3. Squeeze the catches of the I/O connector and push the cable connector into the MX7 Tecton I/O port until it clicks. Theclick means the connector is seated firmly.4. Press the power cable connector pin from the power adapter into the connector on the (USB/Power or Serial/Power)cable attached to the base of the MX7 Tecton. External power is now being supplied to the MX7 Tecton.Whenever possible, use the AC power adapter with the MX7 Tecton to conserve the main battery power and maintain a chargein the internal battery.E-EQ-MX7CEOGWW-ADraft 07 [ 16 ] MX7 Tecton CE User Guide
Connecting Vehicle PowerFor review only - Do not publish or distribute - LXE Confidential - Draft 07Connecting Vehicle PowerComplete vehicle cradle mounting and power instruction is contained in the MX7 Tecton Cradle Guide.The MX7 Tecton must have a main battery installed before docking the MX7 Tecton in a cradle.DC to DC Power Supply InstallationFor use with LXE power supplies:l9000301PWRSPLY – Power Supply, 18-60VDC with cablel9000302PWRSPLY – Power Supply, 60-110VDC with cableConnecting Electrical Cables to Power SourcesThe DC to DC power supply is used to provide vehicle power to the MX7 Tecton when placed in a DC powered vehicle dock.Specifications for Electrical SupplyInput Voltage Always observe input voltage range specified on the DC to DC power supplyOutput Voltage 12 VDC ± 10%Power 50 WFuse 5 A (slow blow fuse). Fuses are USER SUPPLIEDNote: Refer to the Wiring Schematic for wiring colors and connections.Caution: For proper and safe installation, the input power cable must be connected to a fused circuit on the vehicle. Thisfused circuit requires a five Amp maximum time delay (slow blow) high interrupting rating fuse. If the supplyconnection is made directly to the battery, the fuse should be installed in the positive lead within 5 inches of thebattery positive (+) terminal. Note: For North America, a UL Listed fuse is to be used.Caution:For installation by trained service personnel only.Warning:Risk of ignition or explosion. Explosive gas mixture may be vented from battery. Work only in well ventilatedarea. Avoid creating arcs and sparks at battery terminals.E-EQ-MX7CEOGWW-ADraft 07 [ 17 ] MX7 Tecton CE User Guide
Wiring SchematicFor review only - Do not publish or distribute - LXE Confidential - Draft 07Wiring Schematic1. Existing Circuitry on Vehicle2. Forklift Battery3. Main Switch4. 5A slow fuse close to power source5. Power input6. Isolated DC power output7. Green8. Red / Black9. Red / White10. Use color scheme corresponding to input wireprovided11. Brown12. Blue13. Green14. Vehicle mounted cradleHow To Connect Vehicle Electrical Connection1. The vehicle cradle must be empty.2. Begin by connecting the power cable to the MX7 Tecton's vehicle cradle. Work from this connection with the last con-nection being to the vehicle’s power source.3. Route the cable from the cradle to the DC to DC converter.4. Cut the cable to length and strip the wire ends.Route the power cable the shortest way possible. The cable is rated for a maximum temperature of 105°C (221°F).When routing this cable it should be protected from physical damage and from surfaces that might exceed thistemperature. Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate. If thevehicle is equipped with a panel containing Silicon Controller Rectifiers (SCR’s), avoid routing the power cable in closeproximity to these devices.Always route the cable so that it does not interfere with safe operation and maintenance ofthe vehicle.5. Remove the DC to DC converter lid screws. Put them in a safe place.6. Remove the lid from the DC to DC converter.7. Attach the stripped wire ends to the output side of the DC to DC converter.8. Attach the stripped wire ends to the input side of the DC to DC converter.9. The input and output blocks each have two + plus and two – minus connectors. Either connector in the block can beused to connect the matching polarity wire. The input and output blocks also each have two chassis ground con-nections. When connecting the MX7 Tecton cradle to vehicle power, use one chassis ground connector in each block.10. Wire colors depend on the type of device attached. Please refer to this illustration for wire colors.11. Use the looms and wire ties to secure all wiring as shown above, then reattach the cover with the screws.E-EQ-MX7CEOGWW-ADraft 07 [ 18 ] MX7 Tecton CE User Guide
How To Connect Vehicle Electrical ConnectionFor review only - Do not publish or distribute - LXE Confidential - Draft 0712. Connect the DC to DC converter to the vehicle’s electrical system.13. While observing the fuse requirements specified here, connect the power cable as close as possible to the actual bat-tery terminals of the vehicle. When available, always connect to unswitched terminals in the vehicle fuse panel, afterproviding proper fusing.Note: ATTENTION: For uninterrupted power, electrical supply connections should not be made at any point afterthe ignition switch of the vehicle.14. Use proper electrical and mechanical fastening means for terminating the cable. Properly sized “crimp” type electricalterminals are an accepted method of termination. Please select electrical connectors sized for use with 18AWG (1mm2)conductors.15. Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals, tak-ing care not to over tighten and pinch conductors or penetrate outer cable jacket.E-EQ-MX7CEOGWW-ADraft 07 [ 19 ] MX7 Tecton CE User Guide
Vehicle 12V Bare Wire AdapterFor review only - Do not publish or distribute - LXE Confidential - Draft 07Vehicle 12V Bare Wire AdapterPart Number: 9000A079CBL12ML3Caution For proper and safe installation, the input power cable must be connected to a fused circuit on the vehicle. Thisfused circuit requires a Amp maximum time delay (slow blow) high interrupting rating fuse. If the supplyconnection is made directly to the battery, the fuse should be installed in the positive lead within 5 inches of thebattery positive (+) terminal. Note: For North America, a UL Listed fuse is to be used.CautionFor installation by trained service personnel only.WarningRisk of ignition or explosion. Explosive gas mixture may be vented from battery. Work only in well ventilatedarea. Avoid creating arcs and sparks at battery terminals.Vehicle Cable Connection Cable (Fuse Not Shown)1. To Vehicle Battery2. To Vehicle Mounted Device3. Green (GND)4. Brown (DC+)5. Blue (DC-)6. 12 VDCE-EQ-MX7CEOGWW-ADraft 07 [ 20 ] MX7 Tecton CE User Guide
Connecting the Power Cable to the VehicleFor review only - Do not publish or distribute - LXE Confidential - Draft 07Connecting the Power Cable to the Vehicle1. Vehicle Electrical System2. 10 Amp Slow Blow Fuse3. DC +4. DC -5. Vehicle Chassis6. Brown7. Blue8. GreenNote: Correct electrical polarity is required for safe and proper installation. The cradle will not power on or function if thecable is connected with the polarity reversed. See the following figure titled “Vehicle Connection Wiring Color Codes” foradditional wire color-coding specifics.E-EQ-MX7CEOGWW-ADraft 07 [ 21 ] MX7 Tecton CE User Guide
Connecting the Power Cable to the VehicleFor review only - Do not publish or distribute - LXE Confidential - Draft 07How To: Connect Vehicle 12 VDC Connection1. The power cable must be UNPLUGGED from the MX7 Tecton vehicle cradle.2. While observing the fuse requirements specified above, connect the power cable as close as possible to the actual bat-tery terminals of the vehicle. When available, always connect to unswitched terminals in the vehicle fuse panel, afterproviding proper fusing.ATTENTION: For uninterrupted power, electrical supply connections should not be made at anypoint after the ignition switch of the vehicle.3. Route the power cable the shortest way possible. The cable is rated for a maximum temperature of 105°C (221°F).When routing this cable it should be protected from physical damage and from surfaces that might exceed this tem-perature. Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate.Note: If the vehicle is equipped with a panel containing Silicon Controller Rectifiers (SCR’s), avoid routingthe power cable in close proximity to these devices.Always route the cable so that it does not interfere with safe operation and maintenance of the vehicle.Use proper electrical and mechanical fastening means for terminating the cable. Properly sized “crimp” typeelectrical terminals are an accepted method of termination. Select electrical connectors sized for use with18AWG (1mm2) conductors.Wiring color codes for LXE supplied DC input power cabling:Vehicle Supply Wire Color+12VDC (DC +) BrownReturn (DC -) BlueVehicle Chassis (GND) Green4. Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals, tak-ing care not to over tighten and pinch conductors or penetrate outer cable jacket.5. Refer to the following sections to complete the power connection to the MX7 Tecton vehicle cradle.E-EQ-MX7CEOGWW-ADraft 07 [ 22 ] MX7 Tecton CE User Guide
Connect Power Supply to Vehicle CradleFor review only - Do not publish or distribute - LXE Confidential - Draft 07Connect Power Supply to Vehicle CradleThe power cable connector is L-shaped.The long end of the L (the cable) will be facing up towards the middle strain relief cable clamp.Align the connector pins to the vehicle cradle Power connector; firmly pushing the connector into the Power port.Tighten the nut of the plug clockwise until the power cable is securely fastened.Secure the cable to the cradle with the LXE-installed strain relief cable clamp (see section titled Vehicle Cradle Strain ReliefCable Clamp).The power LED on the MX7 Tecton illuminates when it is receiving external power and an MX7 Tecton is docked.Cradle Power Connector PortNote: When an external power supply is used to power this cradle, the external power supply should be UL Listed, withLPS or Class 2 outputs rated 12V, minimum 2 Amps.Pin Signal Wire Color1 Ground (CG) Green2 Return (-) Blue3 +12V (+) BrownE-EQ-MX7CEOGWW-ADraft 07 [ 23 ] MX7 Tecton CE User Guide
Connecting the Headset CableFor review only - Do not publish or distribute - LXE Confidential - Draft 07Connecting the Headset CableHeadset1. Connects to voice cable end of voice cable2. Headphones3. MicrophoneMX7 Tecton Voice CableConnect the MX7 Tecton voice cable I/O connector to the I/O port on the MX7 Tecton. The MX7 Tecton internal microphoneand speaker are automatically disabled.Slide the voice cable ends together until they click shut. Do not twist or bend the connectors.The MX7 Tecton is ready for voice-enabled applications.E-EQ-MX7CEOGWW-ADraft 07 [ 24 ] MX7 Tecton CE User Guide
Adjust Headset / Microphone and Secure CableFor review only - Do not publish or distribute - LXE Confidential - Draft 07Adjust Headset / Microphone and Secure CableThe headset consists of an earpiece, a microphone, a clothing clip and a cable. The headset attaches to the audio cable end ofthe voice cable which attaches to the MX7 Tecton.Align the audio connector and the headset quick connect cable end. Firmly push the cable ends together until they click andlock in place.Do not twist the microphone boom when adjusting the microphone. The microphone should be adjusted to be about two fingerwidths from your mouth.Make sure the microphone is pointed at your mouth. Note the small “Talk” label near the mouthpiece. Make sure the Talk labelis in front of your mouth. The microphone cable can be routed over or under clothing.Under ClothinglLeave the cable exposed only at the top of the collar.lBe sure to leave a small loop of cable to allow movement of your head.Over ClothinglUse clothing clips to hold the cable close to your body.lTuck the cable under the belt, but leave a small loop where it goes under the belt.lDo not wear the cable on the front of your body. It may get in your way or get caught on protruding objects.E-EQ-MX7CEOGWW-ADraft 07 [ 25 ] MX7 Tecton CE User Guide
Attaching the HandstrapFor review only - Do not publish or distribute - LXE Confidential - Draft 07Attaching the HandstrapNote: Either the trigger handle is attached to the MX7 Tecton or the handstrap is attached, not both. LXE recommendsthat, in the absence of a trigger handle, the handstrap be used at all times. LXE pre-installs the handstrap on a MX7Tecton that is purchased without a trigger handle.1. Handstrap Retainer Bracket2. Handstrap and tethered stylus3. Handstrap ClipTool Required: Phillips #1 screwdriver (not supplied by LXE)1. Place the MX7 Tecton with the screen facing down, on a flat stable surface.2. Attach the handstrap retainer bracket to the MX7 Tecton with the screws and washers provided.3. Slip the Handstrap Clip into the bracket at the base of the MX7 Tecton.4. Making sure the closed loop fastener surfaces on the handstrap are facing up, slide the strap through the pin in the bot-tom bracket and the clip.5. Fold each end of the strap over so that the closed loop fastener surfaces mate evenly.6. Test the strap's connection making sure the MX7 Tecton is securely connected to each end of the handstrap's con-nectors.Check the closed loop fastener, retainer bracket and clip connections frequently. If they have loosened, they must be tightenedor replaced before the MX7 Tecton is placed into service again.E-EQ-MX7CEOGWW-ADraft 07 [ 26 ] MX7 Tecton CE User Guide
Attaching the Trigger HandleFor review only - Do not publish or distribute - LXE Confidential - Draft 07Attaching the Trigger HandlePressing the trigger on the trigger handle activates the integrated scanner and functions the same as the Scan key on thekeypad. With the handle installed the Scan key on the keypad remains active. The trigger duplicates the operation.lThe handle is built of a durable, flexible plastic.lThe handle will not detach from the MX7 Tecton if the unit is dropped.lThe trigger handle is a mechanical device. Battery or external A/C power is notrequired for operation.lThe trigger handle does not need to be removed when replacing the main batterypack.lThe trigger handle might also be called a pistol grip.Equipment needed: Torque wrench capable of torquing to 3±1 in/lb (.34±.11 N/m).Either the trigger handle or the handstrap is attached, not both. LXE recommends that, in the absence of a trigger handle, thehandstrap be used at all times.1. Place the MX7 Tecton with the screen facing down, on a flat stable surface.2. Remove the handstrap, if installed.3. Remove the battery.4. Slide the locking tab on the underside of the trigger handle into the slot at the back of the battery compartment and pressit firmly into place.5. Ensure that the battery can be inserted into the battery compartment before securing the trigger handle in place.6. Attach the trigger handle to the MX7 Tecton (as shown above) with the screws provided.7. Torque the pan head screws to 3±1 in/lb (.34±.11 N/m).8. Secure the strap tether to the trigger handle.9. Place the stylus in the stylus holder in the trigger handle.Periodically check the trigger handle for wear and the connection for tightness. If the handle gets worn or damaged, it must bereplaced. If the trigger handle connection loosens, it must be tightened or replaced before the MX7 Tecton is placed in service.E-EQ-MX7CEOGWW-ADraft 07 [ 27 ] MX7 Tecton CE User Guide
Assemble the Carry CaseFor review only - Do not publish or distribute - LXE Confidential - Draft 07Assemble the Carry CaseNote: LXE recommends that accessory installation or removal be performed on a clean, well-lit surface. Whennecessary, protect the work surface, the MX7 Tecton, and components from electrostatic discharge.1. Remove any cables connected to the I/O port at the bottom of the MX7 Tecton.2. Remove the rubber boot from the MX7 Tecton.3. Separate the hook and loop fabric on the carry case without removing the hook and loop fabric from the carry case.4. Slip the removable, clear plastic protector for the keypad and touchscreen into the case. Position it against the openingsfor the keypad and touchscreen in the case. The voice case does not require the clear plastic protector.5. Slide the MX7 Tecton into the case, making sure the touchscreen and keypad (including the Scan LED) are visible andaccessible through the front openings of the case.6. Securely tether the stylus to the case, if necessary. Place the stylus in the stylus holder on the handstrap or in thetrigger handle.7. Loosen then tighten the handstrap (on cases without a trigger handle opening) until the carry case assembly is secure inyour hand.8. When a shoulder strap is available,secure the clips at each end of the shoulder strap to the D rings on either side of thecarry case. The shoulder strap allows the MX7 Tecton to hang upside down until needed.The main battery can be removed and inserted without taking the MX7 Tecton out of the carry case.Carry Case with Metal SnapsThe metal snap has a bulge in the lip and a dot indentation on the opposite side. To snap the cap closed, tuck the lip bulgeunder the snap lip and press on the dot to snap closed.Pull the snap up to open.E-EQ-MX7CEOGWW-ADraft 07 [ 28 ] MX7 Tecton CE User Guide
Set Date and Time ZoneFor review only - Do not publish or distribute - LXE Confidential - Draft 07Set Date and Time ZoneTap Start | Settings | Control Panel | Date/Time icon or tap the Date/Time in the taskbar.Set Date, Time, Time Zone, and assign a Daylight Savings location on the MX7 Tecton.There is very little functional change from standard desktop PC Date/Time Properties options. Adjust the settings and tap theOK button or the Apply button to save changes to the registry. Any changes take effect immediately.Double-tapping the time displayed in the Taskbar causes the Date/Time Properties screen to appear.Using the Input Panel / Virtual KeyboardThe virtual keyboard is always available when needed e.g. text entry.Place the cursor in the text entry field and, using the stylus:lTap the Shift key to type one capital letter.lTap the CAPS key to type all capital letters.lTap the áü key to access symbols.Some applications do not automatically display the Input Panel. In this case, do the following to use the Input Panel:Input Panel icon in the taskbarKeyboard icon in the taskbarlTap the Input Panel or Keyboard icon in the taskbar.lSelect Keyboard from the menu.lMove the cursor into the text entry field when you want to enter data using the Input Panel.When finished entering data, tap the icon in the Taskbar again.Select Hide Input Panel.E-EQ-MX7CEOGWW-ADraft 07 [ 29 ] MX7 Tecton CE User Guide
Set Power Scheme TimersFor review only - Do not publish or distribute - LXE Confidential - Draft 07Set Power Scheme TimersStart | Settings | Control Panel | Power | SchemesChange the parameter values and tap OK to save the changes.Battery Power SchemeUse this option when the MX7 Tecton will be running on battery power only.Switch state to User Idle1Default is After 3 secondsSwitch state to System Idle2Default is After 15 secondsSwitch state to Suspend3Default is After 5 minutesAC Power SchemeUse this option when the MX7 Tecton will be running on external power (e.g. connected to an A/C power source).Switch state to User Idle Default is After 2 minutesSwitch state to System Idle Default is After 2 minutesSwitch state to Suspend Default is After 5 minutesThe timers are cumulative. The System Idle timer begins the countdown after the User Idle timer has expired and the Suspendtimer begins the countdown after the System Idle timer has expired. When the User Idle timer is set to “Never”, the powerscheme timers never place the MX7 Tecton in User Idle, System Idle or Suspend modes (even when the MX7 Tecton is idle).Using the Battery Power Scheme Defaults listed above, the cumulative effect results in the following:lThe backlight turns off after 3 seconds of no activity,lThe display turns off after 18 seconds of no activity (15 seconds + 3 seconds),lAnd the MX7 Tecton enters Suspend after 5 minutes and 18 seconds of no activity.1An amount of time has passed, set by the User Idle timer, and the device shuts down a minimum number of services e.g.backlights. The System Idle timer and the Suspend timer have not expired yet.2An amount of time has passed, set by the System Idle timer, and the device shuts down a few more services e.g. display.The User Idle timer has expired and the Suspend timer has not expired yet.3Suspend mode is entered when (1) the unit is inactive for a predetermined period of time, (2) the user taps the Power key, or(3) Start | Suspend is chosen. Inactivity means that internal devices that reset the power state are not active.E-EQ-MX7CEOGWW-ADraft 07 [ 30 ] MX7 Tecton CE User Guide
Set Speaker VolumeFor review only - Do not publish or distribute - LXE Confidential - Draft 07Set Speaker VolumeThe speaker is located on the front, between MX7 and Tecton.Speaker volume can be adjusted to a comfortable level for the listener by using the keypad or by changing parameters in theVolume & Sounds control panel.Using the KeypadNote: Volume & Sounds (in Settings | Control Panel) must be enabled before the following key sequences can adjust thevolume.The volume is increased or decreased one step each time the volume key sequence is pressed.To adjust speaker volume:lTap the Orange key then the Scan key to enter Volume change mode.lUse the Up Arrow and Down Arrow keys. A beep is emitted at each arrow key press. When the volume reaches max-imum level, two extra beeps are emitted.lPress any key, except the keys you used to adjust the volume, to exit.Volume control using a keypad key press has six volume settings that match those supported by the Volume and SoundsControl panel. Volume does not “roll-over” from minimum to maximum or from maximum to minimum. Continuously holdingdown the up or down arrow keys does not cause an automatic repeat of the up (or down) arrow key.Using the Control PanelTap Start | Settings | Control Panel | Volume & Sounds | Volume tab. Change the volume setting and tap OK to save thechange.You can also select / deselect sounds for key clicks and screen taps and whether each is loud or soft.As the volume scrollbar is moved between Loud and Soft, the MX7 Tecton emits a tone each time the volume increases ordecreases.E-EQ-MX7CEOGWW-ADraft 07 [ 31 ] MX7 Tecton CE User Guide
TouchscreenFor review only - Do not publish or distribute - LXE Confidential - Draft 07TouchscreenCalibrating the TouchscreenIf the touchscreen is not responding properly to stylus taps, you may need to recalibrate the touchscreen.Recalibration involves tapping the center of a target. If you miss the center, keep the stylus on the screen, slide it over thetarget's center, and then lift the stylus.To recalibrate the screen, select Start | Settings | Control Panel | Stylus | Calibration tab.Follow the instructions on the screen and press the Enter key to save the new calibration settings or press Esc to cancel orquit.Adjusting the Display Backlight TimerStart | Settings | Control Panel | Display | BacklightThe backlight settings use the LXE set of default timeouts and are synchronized to the User Idle setting in the Schemes tab inthe Power control panel.When the backlight timer expires, the display backlight is dimmed, not turned off. When both checkboxes are unchecked, thebacklight never turns off (or dims).Default values are 3 seconds for Battery, 2 minutes for External and both the check boxes are enabled.This backlight setting as well as the user idle power scheme controls both the keypad and display backlights.Different timeouts can be set for the backlights when on battery or external power. The backlights timer can be disabled for aparticular mode by unchecking the checkbox. When the backlight timer is disabled, the backlight never turns off (or dims) inthat mode.Apply the Touchscreen Protective FilmFirst, clean the touchscreen of fingerprints, lint particles, dust and smudges.Remove the protective film from its container. Remove any protective backing from the film sheet by lifting the backing from acorner of the film. Discard the backing.Apply the film to the touchscreen starting at one side and smoothing it across the display. If air bubbles appear, raise the filmslightly and continue smoothing the film across the display until it covers the glass surface of the display. If dust, lint orsmudges are trapped between the protective film and the glass display, remove the protective film, clean the display and applythe protective film again.Contact your LXE representative about protective film packs designed specifically for your MX7 Tecton touchscreen.E-EQ-MX7CEOGWW-ADraft 07 [ 32 ] MX7 Tecton CE User Guide
Cleaning the Touchscreen and Scanner ApertureFor review only - Do not publish or distribute - LXE Confidential - Draft 07Cleaning the Touchscreen and Scanner ApertureNote: These instructions are for components made of glass. If there is a removable protective film sheet on the display,remove the film sheet before cleaning the screen.Keep fingers and rough or sharp objects away from the scanning aperture and the mobile device touchscreen.If the glass becomes soiled or smudged, clean only with a standard household cleaner such as Windex® without vinegar oruse Isopropyl Alcohol. Dampen the cloth with the cleaner and then wipe the surface.Do not use paper towels or harsh-chemical-based cleaning fluids since they may result in damage to the glass surface. Use aclean, damp, lint-free cloth.Do not scrub optical surfaces. If possible, clean only those areas which are soiled. Lint and particulates can be removed withclean, filtered canned air.Setup Terminal Emulation ParametersBefore you make a host connection, you will, at a minimum, need to know:lthe alias name or IP address (Host Address) andlthe port number (Telnet Port) of the host system to properly set up your host session.1. Make sure the mobile client network settings are configured and functional. If you are connecting over wireless LAN(802.11x), make sure your mobile client is communicating with the Access Point.2. From Start | Program, run LXE RFTerm or tap the RFTerm icon on the desktop.3. Select Session | Configure from the application menu and select the "host type" that you require. This will depend onthe type of host system that you are going to connect to; i.e. 3270 mainframe, AS/400 5250 server or VT host.4. Enter the "Host Address" of the host system that you wish to connect to. This may either be a DNS name or an IPaddress of the host system.5. Update the telnet port number, if your host application is configured to listen on a specific port. If not, just use thedefault telnet port.6. Select OK.7. Select Session | Connect from the application menu or tap the "Connect" button on the Tool Bar. Upon a successfulconnection, you should see the host application screen displayed.To change options such as Display, Colors, Cursor, Barcode, etc., please refer to these sections in the RFTerm ReferenceGuide for complete descriptions of these and other features.E-EQ-MX7CEOGWW-ADraft 07 [ 33 ] MX7 Tecton CE User Guide
Using the AppLock SwitchpadFor review only - Do not publish or distribute - LXE Confidential - Draft 07Using the AppLock SwitchpadNote: The touchscreen must be enabled. Select Start | Settings | Control Panel | Options | Misc. tab to verifytouchscreen status.Switchpad Menu Switchpad Icon in TaskbarA checkmark indicates applications currently active or available for Launching by the MX7 Tecton user. When Keyboard, onthe Switchpad Menu, is selected, the default input method (Input Panel, Transcriber, or custom input method) is activated.Using the KeypadOne switch key sequence (or hotkey) is defined by the Administrator for the end-user to use when switching between lockedapplications. This is known as the Activation key.When the switch key sequence is pressed on the keypad, the next application in the AppLock configuration is moved to theforeground and the previous application moves to the background. The previous application continues to run in the background.MX7 Tecton key presses affect the application in focus only.Using the TouchscreenThe figure shown above is an example and is shown only to aid in describing how the user can switch between applicationsusing a stylus.When the user taps the Switchpad icon with the stylus, a menu pops up listing the applications available to the user. The usercan tap an application name in the popup menu and the selected application is brought to the foreground. The previousapplication continues to run in the background. Stylus taps affect the application in focus only. When the user needs to use theInput Panel, they tap the Keyboard option. Input Panel taps affect the application in focus only.E-EQ-MX7CEOGWW-ADraft 07 [ 34 ] MX7 Tecton CE User Guide
Connecting Bluetooth DevicesFor review only - Do not publish or distribute - LXE Confidential - Draft 07Connecting Bluetooth DevicesPrerequisites:lThe system administrator has discovered, paired, connected and disconnected (using LXEZ Pairing Control Panel) Blue-tooth devices for each MX7 Tecton.lThe system administrator has enabled and disabled LXEZ Pairing parameters for the MX7 Tecton.lThe system administrator has also assigned a Computer Friendly Name using LXEZ Pairing Control Panel for the MX7Tecton.To connect Bluetooth devices, the MX7 Tecton should be as close as possible and in direct line of sight (distances up to 32.8feet or 10 meters) with the targeted Bluetooth device during the discovery and pairing process.If the devices are in Suspend, tap the power key to wake the MX7 Tecton.Using the correct procedure, wake the targeted Bluetooth device if necessary.There may be audible or visual signals as both devices discover and pair with each other.Taskbar Connection IndicatorMX7 Tecton is connected to one or more of the targeted Bluetooth device(s).MX7 Tecton is not connected to any Bluetooth device.MX7 Tecton is ready to connect with any Bluetooth device.MX7 Tecton is out of range of all paired Bluetooth device(s). Connection is inactive.There may be audible or visual signals from paired devices as they move back into range and re-connect with the Bluetoothhardware in the MX7 Tecton.E-EQ-MX7CEOGWW-ADraft 07 [ 35 ] MX7 Tecton CE User Guide
Reboot SequencesFor review only - Do not publish or distribute - LXE Confidential - Draft 07Reboot SequencesWhen the desktop is displayed or an application begins, the power up sequence is complete. If you have previously saved yoursettings, they will be restored on reboot. Application panel changes are saved when ok is tapped on an application propertiespanel.During the processes that follow there may be small delays while the wireless client connects to the network and Bluetoothrelationships establish or re-establish.Suspend / ResumeQuickly tapping the Power key places the MX7 Tecton in Suspend mode. Quickly tapping the Power key again, pressing anykey, pressing the trigger (on the trigger handle, if installed), or tapping the touchscreen, returns the MX7 Tecton from Suspend.The System LED blinks green when the video display is Off (and the device is not in Suspend Mode or Critical Suspend).orTap Start then tap Suspend. The MX7 Tecton enters suspend mode. Quickly tapping the Power key again, pressing any key,pressing the trigger (on the trigger handle, if installed), or tapping the touchscreen, returns the MX7 Tecton from Suspend.WarmbootA warmboot reboots the computer without erasing any registry data. Configuration settings and data in RAM are preservedduring a warmboot. Network and ActiveSync sessions are lost and any data in running applications that had not beenpreviously saved may be lost. CAB files already installed remain installed.There are several methods available:lUsing the Registry, select Start | Settings | Control Panel | Registry and tap the Warmboot button. The MX7 Tectonimmediately warmboots.lUsing the Start menu, select Start | Run and type WARMBOOT in the text box. Press Enter. The MX7 Tecton imme-diately warmboots. The WARMBOOT text command is not case-sensitive1.lUsing the keypad, press the Ctl key and release it, press the Alt key and release it, press the Del key and release it. TheMX7 Tecton immediately warmboots.1The text typed in the text box can be upper or lower case or a combination of upper and lower case letters.E-EQ-MX7CEOGWW-ADraft 07 [ 36 ] MX7 Tecton CE User Guide
TroubleshootingFor review only - Do not publish or distribute - LXE Confidential - Draft 07TroubleshootingCan’t change the date/time oradjust the volume.AppLock is installed and may be running in User Mode on the MX7 Tecton. AppLock usermode restricts access to the control panels.Touchscreen is not acceptingstylus taps or needs recal-ibration.See "Calibrating the Touchscreen" on page 32when the touchscreen needs recalibration,orif the touchscreen is not accepting stylus taps, press <Ctrl>+<Esc> to force the StartMenu to appear. Use the tab, backtab, arrow keys and Enter to move the highlight to Start |Settings | Control Panel | Registry | Warmboot. Press Enter and the MX7 Tectonwarmboots.MX7 Tecton seems to lockup assoon as it is rebooted.There may be slight delays while the wireless client connects to the network, authorizationfor voice-enabled applications complete, and Bluetooth relationships establish or re-establish.When an application begins, the MX7 Tecton is ready for use.New MX7 Tecton main batteriesdon't last more than a few hours.New batteries must be fully charged prior to first use. Li-Ion batteries (like all batteries) grad-ually lose their capacity over time (in a linear fashion) and never just stop working. This isimportant to remember – the MX7 Tecton is always ‘on’ even when in the Suspend stateand draws battery power at all times.Continuous Scan ModeIf Continuous Scan Mode has been enabled (factory default setting is 'Disabled'), the laser (or imager) is always on anddecoding.Caution: Laser beam is emitted continuously. Do not stare into the laser beam.Note: Low Power Scanner does not support aim mode. Any attempt to adjust the aiming beam using SE955 programmingbarcodes in the Integrated Scanner Programming Guide will fail. The Low Power scanner does not decode Codablock,Code93i, Matrix 2 of 5 or Telepen symbologies.E-EQ-MX7CEOGWW-ADraft 07 [ 37 ] MX7 Tecton CE User Guide
Regulatory Notices and Safety InformationWaste Electrical and Electronic Equipment (WEEE)Important:This symbol is placed on the product to remind users to dispose of Waste Electrical and Electronic Equipment(WEEE) appropriately, per Directive 2002-96-EC. In most areas, this product can be recycled, reclaimed and re-used when properly discarded. Do not discard labeled units with trash. For information about proper disposal,Contact your LXE representative, or visit www lxe com.Class B Digital DeviceNOTICEThis device complies with Part 15 of the FCC Rules [and with RSS-210 of Industry Canada]. Operation is subject to thefollowing two conditions:1. This device may not cause harmful interference, and2. This device must accept any interference received, including interference that may cause undesired operation.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 ofthe FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residentialinstallation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference to radio communications. However, there is no guaranteethat interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or televisionreception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct theinterference by one or more of the following measures:lReorient or relocate the receiving antenna.lIncrease the separation between the equipment and the receiver.lConnect the equipment into an outlet on a circuit different from that to which the receiver is connected.lConsult the dealer or an experienced radio/TV technician for help.NOTICEChanges or modifications made to this equipment not expressly approved by LXE, Inc., may void the FCC authorization tooperate this equipment.EMC Directive RequirementsThis is a Class B product. In a domestic environment this product may cause radio interference in which case the user may berequired to take adequate measures.Industry CanadaThis Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operationis subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must acceptany interference received, including interference that may cause undesired operation.Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Leprésent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériquesde Classe B prescrites dans le Règlement sur le brouillage radioélectrique édits par le ministère des Communications duCanada.E-EQ-MX7CEOGWW-ADraft 07 [ 38 ] MX7 Tecton CE User Guide
RF NoticesFor review only - Do not publish or distribute - LXE Confidential - Draft 07Li-Ion BatteryWhen disposing of the MX7 Tecton main battery, the following precautions should be observed: The battery should bedisposed of properly. The battery should not be disassembled or crushed. The battery should not be heated above 212°F(100°C) or incinerated.NOTICE:This Class B digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe [*] est conforme á la norme NMB-003 du Canada.RF NoticesThis device (FCC ID: KDZLXE-MX7T and IC ID: 1995B-LXEMX7T) contains transmitter Module FCC ID: TWG-SDCMSD30AG and IC ID: 6616A-SDCMSD30AG.RF Safety NoticeCaution:This device was tested for typical body-worn operation. Use only LXE tested and approved accessories to ensureFCC Compliance. The use of third-party accessories may not comply with FCC RF exposure compliancerequirements, and should be avoided. To comply with FCC RF exposure requirements, this device must beoperated in the hand with a minimum separation distance of 2.5 cm (0.9842 inch) or more from a person's body.E-EQ-MX7CEOGWW-ADraft 07 [ 39 ] MX7 Tecton CE User Guide
Laser Light Safety StatementFor review only - Do not publish or distribute - LXE Confidential - Draft 07Laser Light Safety StatementWarning: This product uses laser light. One of the following labels is provided on the scanner. Please read theCaution statement. (US)Mise én garde: Ce produit utilise un rayon laser. L’une des étiquettes suivantes est apposée sur le scanneur. Veuillez lirel’avertissement qu’elle contient. (FR)Advertência: Este produto usa luz de laser. O scanner contém um dos seguintes avisos. Favor ler o Aviso. (PT)Varning: Denna produkt använder laserljus. En av de nedanstående etiketterna sitter på scannern. Var god läs varningstexten.(SE)Advarsel: Dette produkt anvender laserlys. En af følgende mærkater anvendes på scanneren. Læs venligstsikkerhedsforanstaltningen. (DK)Varoitus: Tämä tuote käyttää laservaloa. Skannerissa on jokin seuraavista tarroista. Lue Huomio-kohta. (FI)Warnung: Dieses Produkt verwendet Laserlicht. Eines der folgenden Etiketten befindet sich auf dem Scanner. Bitte lesen Sieden Gefahrenhinweis. (DE)Attenzione: Questo prodotto utilizza luce laser. Una delle etichette seguenti c’ ubicata sullo scanner. Si raccomanda di leggerecon attenzione le avvertenze riportate. (IT)Advarsel: Dette utstyret bruker laserlys. En av følgende etiketter er plassert på scanneren. Les advarselen på etiketten. (NO)Advertencia: Este producto usa luz de láser. Las etiquetas se proveen en la máquina exploradora. Por favor, leadetenidamente la explicación para las precauciones. (ES)Waarschuwing: Dit product gebruikt laserlicht. Een van de volgende labels is op de scanner aangebracht. Lees a.u.b. dewaarschuwing onder Oppassen. (NL)E-EQ-MX7CEOGWW-ADraft 07 [ 40 ] MX7 Tecton CE User Guide
Laser Light Safety StatementFor review only - Do not publish or distribute - LXE Confidential - Draft 07E-EQ-MX7CEOGWW-ADraft 07 [ 41 ] MX7 Tecton CE User Guide
Vehicle Power Supply Connection Safety StatementFor review only - Do not publish or distribute - LXE Confidential - Draft 07Vehicle Power Supply Connection Safety StatementVehicle Power Supply Connection: If the supply connection is made directly to the battery, a A slow-blow fuse should beinstalled in the positive lead within 5 inches (12.7 cm.) of the battery positive (+) terminal. (US)Raccordement de l’alimentation du véhicule Si l’alimentation est raccordée directement à la batterie, un fusible à actionretardée de A doit être installé sur le câble positif à moins de 12,7 cm de la borne positive (+) de la batterie. (FR)EL forsyning af køretøjet. Er forsyningsforbindelsen direkte tilknyttet til batteriet og og tilsluttet til den positive part indenfor12,7 cm (+ delen). vil der være en langsom tændelse af ampere. (DK)Kytkentä ajoneuvon virtalähteeseen Jos virtaa otetaan suoraan akusta, ampeerin hidas sulake on asennettava positiiviseenjohtoon enintään 12 cm:n etäisyydelle akun positiivisesta (+) navasta. (FI)Anschluss an Fahrzeugbatterie Bei direktem Anschluss an die Fahrzeugbatterie sollte eine träge A-Sicherung in die positiveLeitung zwischengeschaltet werden, und zwar nicht weiter als ca. 13 cm von der positiven (+) Batterieklemme entfernt. (DE)Σύνδεση Τροφοδοτικού Ισχύος Οχήματος Αν η σύνδεση του τροφοδοτικού γίνει κατευθείαν στη μπαταρία, μια ασφάλειαβραδείας τήξης των A θα πρέπει να τοποθετηθεί στο θετικό καλώδιο εντός 5 ιντσών (12,7 εκ.) του θετικού (+) ακροδέκτη τηςμπαταρίας. (GR)Collegamento dell’alimentazione del veicolo Se il collegamento dell’alimentazione viene stabilito direttamente con la batteria, ènecessario installare un fusibile ad azione lenta da A nel conduttore positivo a meno di 5 in. (12,7 cm) dal terminale positivo (+)della batteria. (IT)Tilkople strømforsyningen til kjøretøyet Hvis strømforsyningen koples direkte til batteriet, skal det installeres en A treg sikringi den positive ledningen innen 12,7 cm fra plusspolen (+) på batteriet. (NO)Ligação do fornecimento de corrente do veículo Se a ligação de fornecimento de corrente for ligada directamente à bateria,deve instalar-se um fusível de A no terminal positivo, a 12,7 cm. do terminal positivo (+) da bateria. (PT)Conexión de suministro eléctrico para el vehículo Si el suministro eléctrico se proporciona directamente a la batería, se debeinstalar un fusible de retardo de A en el conductor positivo, como máximo a 12,7 cm (5 pulgadas) del terminal positivo (+).(ES)Fordonets strömförsörjningskoppling Om strömkopplingen görs direkt till batteriet, måste en A-säkring installeras i denpositivt laddade ledningen inom 12.7 cm från batteriets pluspol (+). (SE)Taşıt Güç Kaynağı Bağlantısı Kaynak bağlantısı doğrudan aküye yapılırsa, pozitif bağlantı kablosu üzerinde akünün pozitif (+)kutbuna 12.7 cm mesafede A’lık yavaş atan bir sigorta monte edilmelidir. (TR)Legend: Danish – DK; English – US; Finnish – FI; French- - FR; German – DE; Greek – GR; Italian – IT; Norwegian – NO;Portuguese – PT; Spanish – ES; Swedish – SE; Turkish – TR.Revision HistoryRevision / Date Location / ChangeA / Dec 2010 Initial ReleaseE-EQ-MX7CEOGWW-ADraft 07 [ 42 ] MX7 Tecton CE User Guide
IndexAAC Power Scheme 30Adjust Headset / Microphone and Secure Cable 25Alpha mode Status LED 13AppLock Switchpad 34Apply the Touchscreen Protective Film 32AssemblyUSB Host 14-15Attaching the Handstrap 26Attaching the Trigger Handle 27BBatteryRemove 10Battery Power Scheme 30Bluetooth connection 35CCalibrate 32Carry case assembly 28Carry Case with Metal Snaps 28Charge or Recharge the Main Battery 11Class B 38Cleaning the Display 33Client Cable Assembly 14Connect or Remove the Battery Pack 9Connect Power Supply to Vehicle Cradle 23Connecting an External Power Supply 16Connecting Cables 14Connecting the Headset Cable 24Connecting the Serial and Power Cable 15Connecting the USB Client and Power Cable 14Connecting Vehicle Power 17Connection Indicators 35Cradle Power Connector Port 23Cumulative mode timers 30DDate, Time, TimeZone 29Daylight Savings location 29DC to DC Power Supply Installation 17DC to DC PSSpecifications for Electrical Supply 17EEULA 1HHandstrapassembly 26Hardware Setup 1HeadsetAdjusting the microphone 25Mouthpiece Talk label 25quick connectcable25Hide input panel 29Hide online keyboard 29Hotswap the Main Battery 10How ToConnect Power to Vehicle Cradle 23II/O Port and Cables 4Input panel 29LLaser Light Safety Statement 40Laser Warnings and Labels 2LEDSystem Status 13LEDs (Light Emitting Diodes) 13E-EQ-MX7CEOGWW-ADraft 07 [ 43 ] MX7 Tecton CE User Guide
Index P - WFor review only - Do not publish or distribute - LXE Confidential - Draft 07Ppan head screws 27PinoutCradle Power Port 23Power key 1power management status 13Protective film for touchscreen 32RReboot Sequences 36Recalibrate 32Recharge the Main Battery 11Remove Battery 10Resume 36Revision History 42RF Notices 39SSafety StatementVehicle Power Supply 42Scanner Vibration tab 13Serial and Power Cable 15Set Date and Time Zone 29Set Power Scheme Timers 30Set Speaker Volume 31Set Up A New Device 1Setup Terminal Emulation Parameters 33SIP soft input panel 29Software Setup 1Strain Relief Cable Clamps 23Stylushow to use 12Suspend 36Switchpad 34System Status LED 13TToggle Vibrate Indicator 13Toggle vibration motor on and off 13Torque wrench 27Touchscreenand the stylus 12Touchscreen protective film 32Trigger handleassemble 27Troubleshooting 37UUSB host cable assembly 14-15Using the AppLock Switchpad 34VVehicle 12V Bare Wire Adapter 20Vehicle Cable Connection Cable 20Vibrate 13virtual keyboard 29Volume adjust 31WWarmboot 36WEEE 38Wiring Schematic 18E-EQ-MX7CEOGWW-ADraft 07 [ 44 ] MX7 Tecton CE User Guide

Navigation menu