Honeywell CS22A Next Generation Honeywell Access Point User Manual Acc Pt QS

Honeywell International Inc Next Generation Honeywell Access Point Acc Pt QS

User manual

©2010 Honeywell International Inc.   All rights reserved.  ACC-PT-QS Rev (a) 4/10Preliminary Draft 4/28/10Access Point Quick StartConnecting the Access Point1. Turn on the computer (laptop/desktop).2. Plug the interface cable into the Access Point first and then into the appropriate port on the computer.  The Page button lights up when the connection is made.Managing ConnectionsOnly one scanner may be linked to the Access Point at a time.  To link a different scanner to the Access Point, use the new scan-ner to scan the Linking bar code on the Access Point.  That unlinks the first scanner and links the second one.Connection RangeThe scanner is in communication with the Access Point even if it is not transmitting bar code data.  If you take the linked scanner out of range of the Access Point, communication with the module will be lost and you will have to reconnect the scanner to the Access Point.  To reconnect the scanner, scan the Linking bar code.Changing BatteriesIf the scanner turns off due to a low battery, you can change the battery without losing the link with the Access Point, pro-vided the scanner is in range.  A few seconds after the scanner powers up, the scanner relinks to the module.  Refer to your User’s Guide at www.honeywellaidc.com for additional information about charging the batteries.3. Scan the linking bar code on the top of the Access Point to establish a connection between the Access Point and the scanner.  The scanner emits a short beep and flashes the green LED to confirm a connection with the Access Point.  The Access Point’s Page button remains blue.USB Connection:RS232 Connection:RS485 Connection:Keyboard Wedge Connection:Page button
©2010 Honeywell International Inc.   All rights reserved.  ACC-PT-QS Rev (a) 4/10Preliminary Draft 4/28/10Low Power ModeWhen there is no activity within a specified time period, the scanner enters a low power mode.  The default time out period is one  hour.  Pull the scanner’s trigger to power the scanner back up.  If the scanner was linked to the Access Point when it went to “sleep,” it will re-link as long as it is in range.If multiple scanners use the same Access Point, it is possible to inadvertently unlink a scanner that is in “sleep” mode, that has a dead battery, or is in the process of getting a new battery.  To prevent this from happening, you can disable the sleep mode (time out) by scanning the No Time Out bar code below. Unlinking the Scanner from Access PointIf you know that your scanner is not going to be used for a while, you can unlink the scanner by scanning the Unlink Scan-ner bar code below. Page ButtonWhen you press the Page button, the scanner associated with that Access Point will begin beeping (3 short and 1 long beep).  If you pull the trigger on a scanner that is beeping in response, that scanner will stop beeping.  Pressing the Page button a second time will also stop the scanner’s beeping.   LED DimmerScan a bar code to set the brightness of your Page button.Adding Carriage Return SuffixIf you want a carriage return (CR) to display after the bar code data on your output scan the Add CR Suffix bar code below.  Scan the Remove Suffix bar code to remove the suffix.Standard Product DefaultsThis bar code resets all standard product default settings.Note: Resetting standard defaults disconnects the scanner from the Access Point.  Scan the Linking bar code to re-establish a connection.  Refer to your User’s Guide at www.honeywellaidc.com for additional information about product defaults.No Time Out (0)Unlink scannerPage buttonLED Dimmer Off LED Dimmer - DimLED Dimmer - BrightAdd CR Suffix Remove SuffixStandard Product Default Settings
©2010 Honeywell International Inc.   All rights reserved.  ACC-PT-QS Rev (a) 4/10Preliminary Draft 4/28/10Required Safety LabelsProduct SpecificationsTechnical AssistanceContact information for technical support and product service can be found at  www.honeywellaidc.com.Parameter SpecificationDimensions (Typical):Height 1.1 inch (28mm)Length 4.3 inches (109mm)Width 2.8 inches (71mm)Weight 2.3 ounces (66g)Voltage Requirements 5 VDC + 0.5VCurrent Draw 100mA @ 5 volts typicalTemperature Ranges:Operating 32° F to +122° F (0° C to +50° C)Storage -40° F to +158° F (-40° C to +70° C)Radio:Frequency 2.4 to 2.5 GHz (ISM Band) Frequency Hopping Bluetooth v.2.1Range 33 ft. (10 m) typicalData Rate 3MBps (2.1 MBps)Humidity Up to 95% non-condensingMechanical DropOperational after 50 drops from 3.28 feet (1 m) to concreteVibration 5G Peak from 22Hz to 300HzESD SensitivityUp to 15kV direct airUp to 8 kV indirect coupling planeLabel location for item number, serial number, revision information, compliance, and safety information
©2010 Honeywell International Inc.   All rights reserved.  ACC-PT-QS Rev (a) 4/10Preliminary Draft 4/28/10Product Agency ComplianceUSAFCC Part 15 Subpart B Class BThis device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions:1. This device may not cause harmful interference.2. This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the fol-lowing measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio or television technician for help.If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.  The user may find the following booklet helpful: “Something About Interference.”  This is available at FCC local regional offices.  Honeywell is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Honeywell.  The correction is the responsibility of the user.  Use only shielded data cables with this system.Caution:  Any changes or modifications made to this equipment not expressly approved by Honeywell may void the FCC authorization to operate this equipment.UL StatementUL listed: UL60950-1.CanadaIndustry Canada ICES-003This Class B digital apparatus complies with Canadian ICES-003.  Operation is subject to the following conditions:1. This device may not cause harmful interference.2. This device must accept any interference received, including interference that may cause undesired operation.Conformité à la règlementation canadienneCet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada. Son fonctionnement est assujetti aux conditions suivantes :1. Cet appareil ne doit pas causer de brouillage préjudiciable.2. Cet appareil doit pouvoir accepter tout brouillage reçu, y compris le brouillage pouvant causer un fonctionnement indésirable.  cUL Statement cUL listed: CSA C22.2 No.60950-1-03.EuropeThe CE marking indicates compliance to 2004/108/EC EMC Directive with Standards EN55022 CLASS B, EN55024, EN61000-3-2, EN61000-3-3. In addition, complies to 2006/95/EC Low Voltage Directive, when shipped with recommended power supply.For further information please contact:Honeywell Imaging & Mobility Europe BVNijverheidsweg 9-135627 BT EindhovenThe NetherlandsHoneywell International Inc. shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive.Waste Electrical and Electronic Equipment InformationHoneywell complies with Directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment (WEEE).This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment, if not properly disposed.In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way.The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take-back systems for product disposal.If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste administration.You may also contact your supplier for more information on the environmental performances of this product.PatentsPlease refer to the product packaging for patent information.Australia/NZC-Tick StatementConforms to AS/NZS 3548 EMC requirementMexico  Conforms to NOM-019.Russia

Navigation menu