Honeywell 8DLLYNXPLUS2 Wireless Control / Communicator User Manual 800 13012 A VE3 Supplement

Honeywell International Inc. Wireless Control / Communicator 800 13012 A VE3 Supplement

English Supplement

Important Information   The LYNX Plus Series control is equipped with a redesigned circuit board featuring relocated battery and communication port connections and redesigned antennas. Please refer to the figure below and to the Summary of Connections when making wiring connections and routing cables.     1000-300-006-V5LOCALSOUNDERDISABLESWITCHMOUNTINGHOOKSTIE-WRAPPOINTTELEPHONECONNECTIONTERMINALSTRIPBATTERY CABLEWIREROUTINGTUNNELSPOWERLINE CARRIERDEVICE CONNECTORGSMVLP4G AUDIOCABLE CONNECTORTIE WRAPNOTEENSURE ALL WIRINGIS ROUTED THROUGHWIRE STRAINRELIEF CLIPWIRE STRAINRELIEF CLIPTIE WRAPMOUNT   LYNX Plus Wiring and Connection Overview
 85dBSIRENDISABLESWITCHUL INSTALLATIONSTHE MINIMUM WIRESIZE USED FORTELEPHONEINSTALLATIONSMUST BE #26 GAGEWARNINGTO PREVENT RISK OFSHOCK, DISCONNECTTELEPHONE LINEAT TELECOM JACKBEFORE SERVICINGTHIS UNITTHIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.OPERATION IS SUBJECT TO THE FOLLOWING TWOCONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFULINTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANYINTERFERENCE RECEIVED, INCLUDING INTERFERENCETHAT MAY CAUSE UNDESIRED OPERATION.THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCEWITH THE NATIONAL FIRE PROTECTION ASSOCIATIONSTANDARDS ANSI/NFPA 70 NATONAL ELECTRIC CODE ANDNFPA 72 NATIONAL FIRE ALARM CODE, CHAPTER 2(NATIONAL FIRE PROTECTION ASSOC., BATTERY MARCHPARK, QUINCY, MA 02169). PRINTED INFORMATIONDESCRIBING PROPER INSTALLATION, EVACUATIONPLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITHTHIS EQUIPMENT.LYNX PLUS SERIES ALSO COMPLIES WITH THE FOLLOWING:CANADIAN STANDARDS ASSOCIATION (CSA) C22.1,CANADIAN ELECTRICAL CODE, PART 1, SAFETY STANDARDFOR ELECTRICAL INSTALLATIONS AND CAN/ULC-S540INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS.LYNX PLUS SERIES SUMMARY OF CONNECTIONSTHE LYNX PLUS SERIES CONTROLS ARECOMPATIBLE WITH THE FOLLOWINGINTEGRAL RECHARGEABLE BATTERY PACKS:REPLACE EVERY FOUR YEARSP/N LYNXRCHKIT-SCP/N LYNXRCHKIT-HCP/N LYNXRCHKIT-SHACIRCUIT(ZONE) CONTROL UNITDELAY-SEC SMOKE DETECTORMODEL                DELAY-SECTHIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARMVERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF THESYSTEM ALARM SIGNAL FROM THE INDICATED FIRE CIRCUITS.THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS)SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATINGDEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESSAPPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.WARNING5806 10 seconds30 seconds02 - 25ZT161000-300-SOC-V5FCC ID: CFS8DLLYNXPLUS2(LYNX PLUS SERIES)COMPLIES WITH FCC RULES,PART 68 FCC REGISTRATIONNo. 5GBUSA-25623-AL-ERINGER EQUIVALENCE: 0.0043BNOTEUSE ONLY THEK10145WH/K10145X10OR K10145CN CLASS 2TRANSFORMERSPROVIDEDEXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATED BY UL.WEEKLY TESTING ISREQUIRED TO ENSUREPROPER OPERATIONOF THIS SYSTEMPOWER SHUTDOWN NOTE: AT 6.0VDC THE SYSTEM WILL NOT OPERATE.PREMISESTELEPHONEINCOMINGTELEPHONELINE6-14VDC120mA max.BELLHARDWIREDZONEALL OUTPUT CIRCUITS ARE POWER LIMITED. 123486511710PHONE ZONE SOUNDERS ACEARTHGROUNDEARTHGROUND9SUPER HIGH-CAPACITYBATTERY CONNECTORSTANDARD/HIGH-CAPACITYBATTERY CONNECTORTO 24HR 110VACUNSWITCHEDOUTLETK10145WH/K10145X10OR K10145CN PLUG-INTRANSFORMER9VAC, 25VARINGTIPRINGTIPINCOMINGPHONELINE8POSJACKPOWERLINE CARRIERDEVICE CONNECTORGSMVLP4G AUDIOCABLE CONNECTORONAC ACSOUNDOUTHWZTRTR2kOHMSEOLR GSMVLP4GCOMMUNICATIONS PORTHANDSET     2 Corporate Center Drive, Suite 100P.O. Box 9040, Melville, NY 11747Copyright © 2012 Honeywell International Inc.www.honeywell.com/security  Ê800-13012MŠ 800-13012   9/12  Rev. A

Navigation menu