  www.inncom.com  1 L506 Wireless Lamp Control  Module Installation Guide The L506 FET dimmer can drive dimmable CFL loads and other loads: •  100W Incandescent •  35W Dimmable CFL or 100W incandescent equivalent •  25W LED or 100W incandescent equivalent As an alternative to the L206 lamp socket module, the L506 provides wireless lamp control with a smaller footprint. Designed for standard medium lamp sockets (E26 Edison), the RF-equipped device can be controlled from any INNCOM IRAS device with an RF transceiver. The socket is equipped with a mechanical button that can control the load and assist in device binding. The L506 series will eventually incorporate sibling products designed for other lamp socket types. Installation The installer must be a trained, experienced service technician. When installing this product: 1.  Read the instructions carefully. Failure to follow them could damage the product or cause hazardous conditions. 2.  Check the ratings given in the product guide to make sure the product is suitable for your application.. 3.  Use the L506 module only with a recognized or listed lamp holder assembly. CAUTION: The distance between the bulb and the shade should be equal to or greater than required by the original UL listing for the lamp base. Improper placement is a fire hazard.  Mounting  The L506 may be mounted in vertical/bulb up, horizontal, or vertical/bulb down fixtures. CAUTION: The bulb-down orientation should generally be confined to open air installations; if used with a shade, the fixture should be further derated (see table below).  1.  If the lamp’s Edison socket has a switch, make sure it is in the full on position, then remove or disable it. 2.  The L506 dimmer-equipped lamp must be within 60 feet (indoors) of an RF transceiver/repeater. 3.  Unplug the lamp cord from the power source (e.g., wall socket). 4.  Remove any shade and lamp harp. 5.  Remove the bulb; screw the L506 dimmer/switch into the lamp socket. 6.  Reinstall the bulb, then the lamp harp (if used). Rotate the harp if necessary to clear the L506 socket. Plug the lamp back into the power supply. Derating: Do not exceed an ambient air temperature of 25˚C surrounding the L506 Lamp Controller when operating the lamp with the specified loads and orientations, as outlined in the following table.  Maximum Ratings  Vertical Base Down (bulb up) or Horizontal Vertical Base Up (bulb down)* Incandescent  100W  60W Dimmable CFL  35W  20W LED  25W  10W *Open air only. If fixture enclosed, further derating is necessary Communications The L506 can switch on a light using the built-in on/off button. For remote and dimming operation, the L506 must be located within 60 ft. of an originating RF transmitter (any IRAS RF device can be configured as a repeater). The L506 must be commissioned. The outline below assumes the installer understands the commissioning process in general; specific commissioning procedures can be found on the property-specific commissioning sheet. Commissioning The L506 must be bound to an RF control device such as an e528 thermostat.  1.  The L506 enters bind mode for the first 2 minutes after powering up;
  www.inncom.com  2 to re-enter bind mode, unscrew the L506 from the fixture and then screw it back in. 2.  On the e528, enter the Service menu. •  Press and hold the F°/C° button •  Press and release OFF/AUTO •  Press and release DISPLAY •  Release F°/C° 3.  Use the UP or DOWN arrows to go to the Address parameter (ADR). 4.  Press DISPLAY. Use the UP/DOWN arrows to enter the ADR value from the commissioning sheet. 5.  Press OFF/AUTO; a single beep should sound. 6.  On the L506, press and hold the built-in on/off button for 5 seconds. The e528 will beep quickly 3 times to confirm binding. Operation Besides being used in the binding operation, the built-in button on the L506 can control the lighting load. Press and hold the button to adjust lighting (dimming) levels up or down. A quick press will turn the light off or on.  The L506 has a status indicator LED. When the lamp is on, the LED is too. Technical Specifications Parameter  Rating Power  110-120VAC, 50/60Hz 0.9A dimmable output Standby power Standby current 1.3W 11mA Operating Environment 0–25 C˚  Parameter  Rating Dimensions:  63.3mm L × 47.3mm W x 98mm H (with socket) Approvals  FCC Part 15b, Class A, UL FCC ID: GTC202516TXR   This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and  found to comply with the limits for a  Class B digital device, pursuant to  Part 15 of the FCC Rules. These  limits are designed to provide  reasonable protection against  harmful interference in a residential  installation. This equipment  generates, uses, and can radiate  radio frequency energy and, if not  installed and used in accordance with  the instructions, may cause harmful  interference to radio  communications. However, there is  no guarantee that interference will  not occur in a particular installation. If  this equipment does cause harmful  interference to radio or television  reception, which can be determined  by turning the equipment off and on,  the user is encouraged to try to  correct the interference by one of the  following measures:   —Reorient or relocate the receiving  antenna.   —Increase the separation between  the equipment and receiver.   —Connect the equipment into an  outlet on a circuit different from that  to which the receiver is connected.   —Consult the dealer or an  experienced radio/TV technician for  help.     Any changes or modifications not  expressly approved by the party  responsible for compliance could  void the user's authority to operate  this equipment.    C ID: 1609A-202516TXR  This device complies with Industry  Canada license-exempt RSS  standard(s). Operation is subject to  the following two conditions: (1) this  device may not cause interference,  and (2) this device must accept any  interference, including interference  that may cause undesired operation  of the device.     Le présent appareil est conforme aux
  www.inncom.com  3 CNR d’industrie Canada applicables  aux appareils radio exempts de  licence. L’exploitation est autorisée  aux deux conditions suivantes: (1)  l’appareil ne doit pas produire de  brouillage, et (2) l’utilisateur de  l’appareil doit accepter tout brouillage  radioélectrique subi, même si le  brouillage est susceptible d’en  compromettre le fonctionnement.

Navigation menu