Honeywell orporated DR4220 Proximity Reader User Manual 7600033D 4220 4 5 02

Honeywell International Incorporated Proximity Reader 7600033D 4220 4 5 02

Contents

Users Manual

August 2, 2006                                                                                                                                                   Document 7600033© 2006 Honeywell International. All rights reserved.                   Revision F         Installation NotesDigiReader ® DR4220IC: 573G-DR4220FCC ID: C4PDR4220(The term "IC:" before the radio certification number only signifies that Industry Canada technical specifications were met.) Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
   Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.   If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  •  Reorient or relocate the receiving antenna.  •  Increase the separation between the equipment and receiver.  •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  •  Consult the dealer or an experienced radio/TV technician for help.
DigiReader DR4220 Installation Notes DIGIREADER DR4220 INSTALLATION NOTESDIP ADDRESS SWITCHTheDR4220readerhasa5-positionDIP-switchS1,(asshown to the right, with S-NET address 1 selected).INTERNAL INTERFACE CABLEAn attached pigtail cable assembly provides the connection from the printed circuitassembly to the access control unit wiring on a DigiReader DR4220. The cable is color-coded as follows:TAMPERThe DR4220 sends a tamper signal to an S-NET-based ACU when a tamper occurs.Switch S1 Settings S-NET Addressor Function12345 Switch S1 Settings S-NET Addressor FunctionOff Off Off Off Off Off-line 0 12345On Off Off Off Off 1 On On Off On Off 11Off On Off Off Off 2 Off Off On On Off 12On On Off Off Off 3 On Off On On Off 13Off Off On Off Off 4 Off On On On Off 14On Off On Off Off 5 On On On On Off 15Off On On Off Off 6 Off Off Off Off On 16On On On Off Off 7 Off On Off On On Wiegand I/F (26-bit)Off Off Off On Off 8 On On Off On On Wiegand I/F (34-bit)On Off Off On Off 9 Off On On On On DEMO ModeOff On Off On Off 10 On On On On On TEST ModeCOLOR FUNCTION (S-NET Use) (Wiegand Use)Red +12.5 to +24VDC(max. draw 500mA)S-NET Nominal Wiegand NominalGreen S-NET A For use with NexWatchaccess control panels NAWhite S-NET BBlack GND S-NET DC Return Wiegand DC ReturnShield Earth S-NET Shield Wiegand Shield: Tied to Wiegand DC ReturnBlue Data 0 (Out 0)NAFor use with Wiegandaccess control panelsOrange Data 1 (Out 1)Yellow LED 0 (Green) Both LEDs are ACU-controlledand are ON/low or OFF/highBrown LED 1   (Red)12 34 5ONOFFP/N 7-600033 Rev. F1 ©Honeywell International. All Rights Reserved.
DigiReader DR4220 Installation Notes MOUNTING INSTRUCTIONS:Carefully choose the installation site to avoid possible external sources of RF interfer-ence. Interference may cause reduced performance, so DO NOT locate the unit nearmotors, pumps, generators, DC-AC converters, AC switching relays, light dimmers, etc.,or within 10 feet (3 m) of a computer terminal.WARNING: DO NOT mount the unit on or near any typeof metal, including nonferrous metals such as aluminum. (Metal maycause reduced performance or possible damage to the unit.) The unitmay NOT operate properly if it is in near to, or mounted directly onmetal, reinforced steel in concrete, screens, or reinforcing bars. In addi-tion, the unit must not be framed with or surrounded by metal of any kind. If the unit mustbe mounted near metal structures, ensure that it has a minimum of 10 inches (25.4 cm)clearance at the rear and surrounding sides. Never cover the front of the DigiReader withany type of metal. Metal anywhere near the device can reduce the read range. In gen-eral, as the amount of metal close to the device increases, the reliable maximum readrange decreases.PEDESTAL-MOUNTINGINSTRUCTIONS:There must be no conducting metal closerthan 10 inches to the DR4220 reader, ex-cept for a unit mounted with a goose-neckpedestal mounting tube, as shown in figure 1.The recommended mounting methods follow:1. Remove the case front (cover).2. Use the NexWatch-supplied drilling tem-plate to pre-drill 4 holes on the plywoodor LEXAN®sheet (recommended ¾" thick).A channel must be cut into the plywoodor LEXAN®for the cable between the exitpoint of the reader and the goose-neck.3. Mount the plywood or LEXAN®sheet to agoose-neck pedestal mounting tube. (Aminimum of 10" clearance is recommendedbetween the back of the reader and thevertical metal tubing). Center the mountingtube. (See figures 1 and 2.)Figure 23/4" Plywood or Lexan Sheet10” MinimumClearance BetweenBack of Reader andVertical Metal TubingGoose-Neck Assembly Mounted toLexan /Plywoodin Middle ofTransmitCoilFigure 1RRP/N 7-600033 Rev. F2 ©Honeywell International. All Rights Reserved.
DigiReader DR4220 Installation Notes 4. See the INTERNAL INTERFACE CABLEsectiononpage1toinstallthecolor-coded pigtail cable.5. Route the cable through a channel on theplywood or LEXAN®sheet. (See page 4:RECOMMENDED STAND-OFF PLATE.)6. Mount the DR4220 board and case back(back plate) to the plywood or LEXAN®sheet which is securely attached to thegoose-neck as shown in figure 3.7. Set the address switch, as required.8. Install the case front (cover) and be surethat the LED is not damaged as it entersthe lens assembly.9. Secure the case front four holes with thesupplied screws. (See figure 4.)WALL-MOUNTING INSTRUCTIONS:There must be no conducting metal closer than 10 inches to the DR4220 reader.The recommended mounting methods follow:1. Remove the case front (cover).2. Use the NexWatch-supplied drilling temp-late (included with reader) to drill fourholes in the wall.3. Follow the INTERNAL INTERFACE CABLEinstructions to install the pigtail cable.(See page 1.)4. Mount the DR4220 board and case back(back plate) using 2¼" Panhead #6-32thread screws (or other means approp-riate to the wall composition).5. Set the address switch, as required.6. Install the case front (cover) and be surethat the LED is not damaged as it entersthe lens assembly.7. Secure the case front four holes with thesupplied screws. (See figure 4.)Figure 4Figure 3 P/N 7-600033 Rev. F3 ©Honeywell International. All Rights Reserved.
DigiReader DR4220 Installation NotesRECOMMENDED STAND-OFF PLATEMaterial is 3/4” LEXAN®, plywood or equivalent.LEXAN® is a Registered Trademark of General Electric Corporation.Specifications subject to change without notice.© Honeywell International. All rights reserved.Document 7-600033, Revision FHoneywell 135 West Forest Hill AvenueOak Creek, WI  53154(414) 766-1700 Ph(414) 766-1798 Faxwww.honeywell.comHoneywell – EuropeBoeblingerstrasse 1771101 SchonaichGermany