Honeywell Security Sensor CoE DUAL TEC Motion Sensor 800 15445 B DT8050M QIG 12 10 13

Contents

User Manual (2 of 2).PDF

    DT8050M  DUAL TEC® Motion Sensor -  Quick Installation Guide DT8050M  DUAL TEC® Motion Sensor -  Quick Installation Guide (FR) DT8050M  DUAL TEC® Motion Sensor -  Quick Installation Guide (SP) DT8050M  DUAL TEC® Motion Sensor -  Quick Installation Guide (PG) 16' 9" - 8' 9"(2.1 - 2.7 m)7' 6"(2.3 m)Optimal Optimal Optimal Optimal  2321  3#6 (3.5 mm)AAAB BB BB BAB#6 x 1 1/4"(3.5 mm x 32 mm)X X   4Microwave Range AdjustmentRéglage de la portée HyperfréquenceAjuste del rango de detección MicroondasAjuste de Alcance Microondas * Factory default / Réglage usine /   Defecto de fábrica / Padrão de fábrica  ONLED*Not UsedNot UsedNot UsedNot UsedMWSENSITIVITYMAX*MIN*Internal EOL Resistor DIP Switches Résistance interne EOL commutateur DIPInterruptores DIP internos EOL ResistorEOL interno Resistor DIP SwitchesEOLKOhmON1 2.2 5.62*DT8050MAM LEDEOLPULLTO DISABLELOOK DOWNLOOK DOWNONOFFONW1MWSENSITIVITYMAXKOhmON1 2 2.2 5.6 DRAFT - QUICK INSTALL GUIDE - 12/10/13
- 2 -  524-20 AWG(0.2-0.52mm2)212Tamper30 mA25 VDCTrouble30 mA25 VDCPower18 mA9 - 15 VDCAlarm30 mA25 VDCLED0 VDC - Vsupply1.8 mA maxLED TBL T C V-V+T NCTBL9 8 6 4 2 15 37EOLKOhmON1 2.2 5.62EOL    WIRING EXAMPLES / WIRING EXAMPLES / WIRING EXAMPLES To connect alarm and tamper outputs (NO trouble) to one zone input:  All alarm and tamper events are “alarms” when the system is armed or “fault” when disarmed. (FR) To connect alarm and tamper outputs (NO trouble) to one zone input:  All alarm and tamper events are “alarms” when the system is armed or “fault” when disarmed. (SP) To connect alarm and tamper outputs (NO trouble) to one zone input:  All alarm and tamper events are “alarms” when the system is armed or “fault” when disarmed. (PG) To connect alarm and tamper outputs (NO trouble) to one zone input:  All alarm and tamper events are “alarms” when the system is armed or “fault” when disarmed.   ZoneCOM Ground +12VControl PanelZone#LED TBL T C V-V+T NCTBL9 8 6 4 2 15 37SensorEOLKOhmON1 2.2 5.62EOL(On-Board, Internal EOLR) To connect all three outputs (sensor alarm, tamper and trouble) to one zone input:  All alarm, tamper and trouble events are “alarms” when the system is armed or “fault” when disarmed. FR) To connect all three outputs (sensor alarm, tamper and trouble) to one zone input:  All alarm, tamper and trouble events are “alarms” when the system is armed or “fault” when disarmed. ES) To connect all three outputs (sensor alarm, tamper and trouble) to one zone input:  All alarm, tamper and trouble events are “alarms” when the system is armed or “fault” when disarmed. PG) To connect all three outputs (sensor alarm, tamper and trouble) to one zone input:  All alarm, tamper and trouble events are “alarms” when the system is armed or “fault” when disarmed. ZoneCOM GroundZone#+12VControl Panel(On-Board, Internal EOLR)LED TBL T C V-V+T NCTBL9 8 6 4 2 15 37EOLKOhmON1 2.2 5.62EOLSensor
- 3 -  To connect the sensor alarm output to one zone input and the tamper and trouble outputs to a second zone input:  The alarm relay is wired to one zone; the tamper and trouble are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble conditions. To connect the sensor alarm output to one zone input and the tamper and trouble outputs to a second zone input:  The alarm relay is wired to one zone; the tamper and trouble are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble conditions. To connect the sensor alarm output to one zone input and the tamper and trouble outputs to a second zone input:  The alarm relay is wired to one zone; the tamper and trouble are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble conditions. To connect the sensor alarm output to one zone input and the tamper and trouble outputs to a second zone input:  The alarm relay is wired to one zone; the tamper and trouble are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble conditions. * ZoneCOM Ground +12VControl PanelTroubleZoneAlarmZoneW1* Off-Board, External EOLR (Not supplied),best if installed inside the sensor housing.LED TBL T C V-V+T NCTBL9 8 6 4 2 15 37CutEOLKOhmON1 2.2 5.62EOLSensor(On-Board, Internal EOLR)JUMPER To connect the sensor alarm, tamper and trouble outputs to three separate zone inputs:  The alarm, tamper and trouble are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble conditions. To connect the sensor alarm, tamper and trouble outputs to three separate zone inputs:  The alarm, tamper and trouble are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble conditions. To connect the sensor alarm, tamper and trouble outputs to three separate zone inputs:  The alarm, tamper and trouble are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble conditions. To connect the sensor alarm, tamper and trouble outputs to three separate zone inputs:  The alarm, tamper and trouble are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble conditions. * * ZoneCOM Ground +12VControl PanelTamperZoneAlarmZoneTroubleZoneZoneCOMLED TBL T C V-V+T NCTBL9 8 6 4 2 15 37W1CutEOLKOhmON1 2.2 5.62EOL* Off-Board, External EOLR (Not supplied),best if installed inside the sensor housing.Sensor(On-Board, Internal EOLR)    630 sec  300452010ONMWSENSITIVITYMAXMINLEDWalk Test Reset4X(slowly)  < 4 ft /1.2m    LED Power Up  Walk Test  Normal  Trouble Red  Slow  Blink ON  Alarm ON  Alarm Fast  Blink Yellow  OFF  ON  Microwave ON  Microwave  OFF Green  OFF  ON PIR  ON PIR  OFF
- 4 -  7Top ViewVue de dessus  Vista Desde ArribaVista Superior  Side ViewVue de coté Vista LateralVista Lateral 00.51.852.3mPLAN  VIEW ALL  ZONES7’ 2 m0013’ 4 m20’ 6 m27’ 8 m33’ 10 m40’ 12 m7’ 2 m13’ 4 m20’ 6 m27’ 8 m33’ 10 m40’ 12 m7’ 2 m13’ 4 m20’ 6 m27’ 8 m33’ 10 m40’ 12 m 46’ 14 m53’ 16 m7’ 2 m013’ 4 m20’ 6 m27’ 8 m33’ 10 m40’ 12 m46’ 14 m53’ 16 mA B C D  APPROVAL/ LISTINGS:  •  FCC part 15, Class B verified  •  IC ICES-003, Class B verified  •  UL 639  •  ULC S306-03  •  SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity.   NOTES:  Product must be tested at least once each year.  For appropriate wiring methods, refer to the National Electrical Code NFPA 70 and the Canadian Electrical Code (where applicable). Power must be provided by a power-limited UL603 Listed burglar alarm power supply with minimum 4 hours of standby power capability, or from a power-limited output of a UL Listed burglar alarm control unit with minimum 4 hours of standby power capability.                                        For the latest documentation and online support information, please go to: Pour de l’assistance en ligne, visitez : Para recibir soporte en línea, visite: Para qualquer informação adicional, contacte: http://www.security.honeywell.com/hsc/resources/MyWebTech/       For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or Please contact your local authorized Honeywell representative for product warranty information. Pour obtenir de l'information sur la garantie de ce produit, veuillez communiquer avec le représentant autorisé de Honeywell       de votre région. Por favor contacte con su distribuidor Honeywell Security para información sobre la garantía del producto. Contacte o representante autorizado Honeywell local para obter informações relativas a garantia.  2013 Honeywell International Inc.  Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc.   All other trademarks are the properties of their respective owners.  All rights reserved.   Made in China.   P/N 800-15445  12/13  Rev B    2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 www.honeywell.com/security     To protect the environment, a detailed installation guide is available on the Honeywell website – Please consider before printing the document!    FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.  CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •   If using an indoor antenna, have a quality outdoor antenna installed. •   Reorient the receiving antenna until interference is reduced or eliminated. •   Move the radio or television receiver away from the receiver/control. •   Move the antenna leads away from any wire runs to the receiver/control. •   Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. •   Consult the dealer or an experienced radio/TV technician for help.  INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. Zones / Zones / Zonas / Zonas A 2 Look-down / Basses / Vista Zona 0 / Vigilância inferior B 12 Lower / Courtes / Cercana/ Mais baixas C 10 Intermediate / Intermédiaires / Intermedia / Intermédias D 36 Long / Longues / Largo Alcance /  Longo alcance