Hewlett Packard Enterprise AP105SDR Aruba AP-105 Wireless Access Point User Manual IAP105 IG

Aruba Networks, Inc. Aruba AP-105 Wireless Access Point IAP105 IG

Manual

  IAP-105 Wireless Access PointInstallation GuideAbout the Aruba IAP-105 Access PointThe Aruba IAP-105 wireless access point supports the IEEE 802.11n standard for high-performance WLAN. This access point uses MIMO (Multiple-in, Multiple-out) technology and other high-throughput mode techniques to deliver high-performance, 802.11n 2.4 GHz and 5 GHz functionality while simultaneously supporting existing 802.11a/b/g wireless services.The Aruba IAP-105 access point provides the following capabilities:Wireless transceiverProtocol-independent networking functionalityIEEE 802.11a/b/g/n operation as a wireless access pointIEEE 802.11a/b/g/n operation as a wireless air monitorCompatibility with IEEE 802.3af PoEPackage ContentsIAP-105 access pointInstallation guide (this document)Aruba Instant Quick Start GuideFigure 1  IAP-105IAP-105 Hardware OverviewFigure 2  IAP-105 FrontLEDsThe IAP-105 is equipped with four LEDs that indicate the status of the various components of the IAP.PWR: Indicates whether or not the IAP-105 is powered-onENET: Indicates the status of the IAP-105’s Ethernet port11A/N: Indicates the status of the 802.11a/n radio11B/G/N: Indicates the status of the 802.11b/g/n radioFor information about the IAP-105’s LED behavior, see Table 1 on page 2.Figure 3  IAP-105 RearConsole PortUse the console port to connect to a terminal for direct local management.Ethernet PortIAP-105 is equipped with a single 10/100/1000Base-T (RJ-45) auto-sensing, MDI/MDX wired-network connectivity port. This port supports IEEE 802.3af Power over Ethernet (PoE) compliance, accepting 48VDC as a standard defined Powered Device (PD) from a Power Sourcing Equipment (PSE) such as a PoE midspan injector, or network infrastructure that supports PoE.DC Power SocketIf PoE is not available, an optional Aruba IAP AC-DC adapter kit (sold separately) can be used to power the IAP-105. Reset ButtonThe reset button can be used to return the IAP to factory default settings. If you have converted your IAP to a campus AP, pressing the reset button converts it back to an IAP. To reset the IAP:1. Power off the IAP.2. Press and hold the reset button using a small, narrow object, such as a paperclip.3. Power-on the IAP without releasing the reset button. The power LED will flash within 5 seconds.4. Release the reset button.The power LED will flash again within 15 seconds indicating that the reset is completed. The IAP will now continue to boot with the factory default settings.Before You BeginIAP Pre-Installation ChecklistBefore installing your IAP-105 access point, be sure that you have the following:CAT5 UTP cable of required lengthOne of the following power sources:IEEE 802.3af-compliant Power over Ethernet (PoE) sourceThe POE source can be any power source equipment (PSE) Aruba IAP AC-DC adapter kit (sold separately)Summary of the Setup ProcessSuccessful setup of an IAP-105 access point consists of five tasks, which must be performed in this order:1. Identify the specific installation location for each IAP.2. Install each IAP.3. Verify post-installation connectivity.4. Configure each IAP.Identifying Specific Installation LocationsYou can mount the IAP-105 access point on a wall or on the ceiling. Each location should be as close as possible to the center of the intended coverage area and should be free from obstructions or obvious sources of interference. These RF absorbers/reflectors/interference sources will impact RF propagation and should have been accounted for during the planning phase and adjusted for in VisualRF.Identifying Known RF Absorbers/Reflectors/Interference SourcesIdentifying known RF absorbers, reflectors, and interference sources while in the field during the installation phase is critical. Make sure that these sources are taken into consideration when you attach an IAP to its fixed location.RF absorbers include:Cement/concrete—Old concrete has high levels of water dissipation, which dries out the concrete, allowing for potential RF propagation. New concrete has high levels of water concentration within the concrete, blocking RF signals.Natural Items—Fish tanks, water fountains, ponds, and treesBrickRF reflectors include:Metal Objects—Metal pans between floors, rebar, fire doors, air conditioning/heating ducts, mesh windows, blinds, chain link fences (depending on aperture size), refrigerators, racks, shelves, and filing cabinetsDo not place an IAP between two air conditioning/heating ducts. Make sure that APs are placed below ducts to avoid RF disturbances.RF interference sources include:Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones)Cordless headset such as those used in call centers or lunch roomsInstalling the IAPUsing the Integrated Wall-Mounting SlotsThe keyhole-shaped slots on the back of the IAP can be used to attach the device upright to an indoor wall or shelf. When you choose the mounting location, allow additional space at the right of the unit for cables.1. Since the ports are on the back of the device, make sure that you mount the IAP in such a way that there is a clear path to the Ethernet port, such as a pre-drilled hole in the mounting surface.2. At the mounting location, install two screws on the wall or shelf, 1 7/8 inches (4.7 cm) apart. If you are attaching the device to drywall, Aruba recommends using appropriate wall anchors (not included).3. Align the mounting slots on the rear of the IAP over the screws and slide the unit into place (see Figure 4).Figure 4  Installing the IAP-105 Access Point on a WallUsing the Integrated Ceiling Tile Rail SlotsThe snap-in tile rail slots on the rear of the IAP can be used to securely attach the device directly to a 15/16" wide, standard ceiling tile rail.1. Pull the necessary cables through a prepared hole in the ceiling tile near where the IAP will be placed.2. If necessary, connect the console cable to the console port on the back of the IAP.Hold the IAP next to the ceiling tile rail with the ceiling tile rail mounting slots at approximately a 30-degree angle to the ceiling tile rail (see Figure 5). Make sure that any cable slack is above the ceiling tile.Figure 5  Orienting the Ceiling Tile Rail Mounting Slots3. Pushing toward the ceiling tile, rotate the IAP clockwise until the device clicks into place on the ceiling tile rail.Connecting Required CablesInstall cables in accordance with all applicable local and national regulations and practices.Ethernet PortsThe RJ45 Ethernet port (ENET) supports 10/100/1000Base-T auto-sensing MDI/MDX connections. Use these ports to connect the IAP to a twisted pair Ethernet LAN segment. Use a 4- or 8-conductor, Category 5 UTP cable up to 100 m (325 feet) long.Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the carton, including the original packing materials. Use these materials to repack and return the unit to the supplier if needed.AP105_005AP105_001105PWRENET 11B/G/N11A/N!FCC Statement: Improper termination of access points installed in the United States (non-US Regulatory Domain model/s) will be in violation of the FCC grant of equipment authorization. Any such willful or intentional violation may result in a requirement by the FCC for immediate termination of operation and may be subject to forfeiture (47 CFR 1.80).!EU Statement: Lower power radio LAN product operating in 2.4 GHz and 5 GHz bands. Please refer to the Aruba Instant User Guide for details on restrictions.Produit réseau local radio basse puissance operant dans la bande fréquence 2.4 GHz et 5 GHz. Merci de vous referrer au Aruba Instant User Guide pour les details des restrictions.Low Power FunkLAN Produkt, das im 2.4 GHz und im 5 GHz Band arbeitet. Weitere Informationen bezlüglich Einschränkungen finden Sie im Aruba Instant User Guide.Apparati Radio LAN a bassa Potenza, operanti a 2.4 GHz e 5 GHz. Fare riferimento alla Aruba Instant User Guide per avere informazioni detagliate sulle restrizioni.AP105_002CONSOLEENET12V       1.25ACONSOLEENETPower ConnectorReset ButtonAruba Networks, Inc., in compliance with governmental requirements, has designed the IAP-105 access points so that only authorized network administrators can change the settings. For more information about IAP configuration, refer to the Aruba Instant Quick Start Guide and Aruba Instant User Guide.!Access points are radio transmission devices and as such are subject to governmental regulation. Network administrators responsible for the configuration and operation of access points must comply with local broadcast regulations. Specifically, access points must use channel assignments appropriate to the location in which the access point will be used.!RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 13.78 inches (35 cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems.Service to all Aruba Networks products should be performed by trained service personnel only.!Make sure the IAP fits securely on the ceiling tile rail when hanging the device from the ceiling; poor installation could cause it to fall onto people or equipment.AP105_003AP105_004
IAP-105 Wireless Access PointInstallation Guidewww.arubanetworks.com1344 Crossman AvenueSunnyvale, California 94089Phone: 408.227.4500Fax 408.227.4550IAP-105 Wireless Access Point | Installation GuidePart Number 0510860-03 | May 2011Contacting Aruba NetworksTable 1  Contact Center OnlineMain Site http://www.arubanetworks.com Support Site https://support.arubanetworks.com Wireless Security IncidentResponse Team (WSIRT) http://www.arubanetworks.com/support/wsirt.phpEMEA Support Email emea.support@arubanetworks.comWSIRT EmailPlease email details of any securityproblem found in an Aruba product.wsirt@arubanetworks.comTable 2  Service & Support Contact Center TelephoneAruba Corporate +1 (408) 227-4500FAX +1 (408) 227-4550SupportUnited StatesUniversal Free Phone Service Number (UIFN): Australia, Canada, China, France, Germany, Hong Kong, Ireland, Israel, Japan, Korea, Singapore, South Africa, Taiwan, and the UKAll Other Countries800-WI-FI-LAN (800-943-4526)+800-4WIFI-LAN (+800-49434-526)+1 (408) 754-1200Copyright© 2011 Aruba Networks, Inc.  AirWave®, Aruba Networks®, Aruba Mobility Management System®, Bluescanner, For Wireless That Works®, Mobile Edge Architecture, People Move. Networks Must Follow., RFProtect®, The All Wireless Workplace Is Now Open For Business, and The Mobile Edge Company® are trademarks of Aruba Networks, Inc. All rights reserved. All other trademarks are the property of their respective owners.Open Source CodeCertain Aruba products include Open Source software code developed by third parties, including software code subject to the GNU General Public License ("GPL"), GNU Lesser General Public License ("LGPL"), or other Open Source Licenses. The Open Source code used can be found at this site:http://www.arubanetworks.com/open_sourceLegal NoticeThe use of Aruba Networks, Inc. switching platforms and software, by all individuals or corporations, to terminate other vendors' VPN client devices constitutes complete acceptance of liability by that individual or corporation for this action and indemnifies, in full, Aruba Networks, Inc. from any and all legal actions that might be taken against it with respect to infringement of copyright on behalf of those vendors.WarrantyThis hardware product is protected by the Aruba Limited Lifetime warranty. Altering this device (such as painting it) voids the warranty.The 10/100/1000 Mbps Ethernet port is on the back of the IAP. The port has an RJ-45 female connector with the pin-outs shown in Figure 6.Figure 6  Gigabit Ethernet Port Pin-OutSerial Console PortThe serial console port (Console) allows you to connect the IAP to a serial terminal or a laptop for direct local management. This port is an RJ-45 female connector with the pinouts described in Figure 7. Connect this port in one of the following ways:Connect it directly to a terminal or terminal server using an Ethernet cable.Use a modular adapter to convert the RJ-45 (female) connector on the IAP to a DB-9 (male) connector, and connect the adapter to a laptop using an RS-232 cable. See Figure 8 for connector details of the adapter.Figure 7  Serial Port Pin-OutFigure 8  RJ-45 (Female) to DB-9 (Male) Modular Adapter ConversionPower ConnectionThe IAP-105 has a single 12V DC power jack socket to support powering through an AC-to-DC power adapter.Verifying Post-Installation ConnectivityThe integrated LEDs on the IAP can be used to verify that the IAP is receiving power and initializing successfully (see Table 1). Refer to the Aruba Instant Quick Start Guide for further details on verifying post-installation network connectivity.Product SpecificationsElectricalEthernet:1 x 10/100/1000Base-T auto-sensing Ethernet RJ-45 InterfacesMDI/MDXIEEE 802.3 (10Base-T), IEEE 802.3u (100Base-T). IEEE 802.3ab (1000Base-T)Power over Ethernet (IEEE 802.3af compliant), 48V DC/350mA (see Figure 6 for pin configuration)Power: 12 VDC power interface, supports powering through an AC-to-DC power adapterFor additional specifications on this product, please refer to the data sheet. The data sheet can be found at www.arubanetworks.com.Proper Disposal of Aruba EquipmentFor the most current information about Global Environmental Compliance and Aruba products, see our website at www.arubanetworks.com.Waste of Electrical and Electronic EquipmentAruba products at end of life are subject to separate collection and treatment in the EU Member States, Norway, and Switzerland and therefore are marked with the symbol shown at the left (crossed-out wheelie bin). The treatment applied at end of life of these products in these countries shall comply with the applicable national laws of countries implementing Directive 2002/96EC on Waste of Electrical and Electronic Equipment (WEEE).European Union RoHSAruba products also comply with the EU Restriction of Hazardous Substances Directive 2002/95/EC (RoHS). EU RoHS restricts the use of specific hazardous materials in the manufacture of electrical and electronic equipment. Specifically, restricted materials under the RoHS Directive are Lead (including Solder used in printed circuit assemblies), Cadmium, Mercury, Hexavalent Chromium, and Bromine. Some Aruba products are subject to the exemptions listed in RoHS Directive Annex 7 (Lead in solder used in printed circuit assemblies). Products and packaging will be marked with the “RoHS” label shown at the left indicating conformance to this Directive.China RoHSAruba products also comply with China environmental declaration requirements and are labeled with the “EFUP 10” label shown at the left.Safety and Regulatory ComplianceAruba Networks provides a multi-language document that contains country-specific restrictions and additional safety and regulatory information for all Aruba access points. This document can be viewed or downloaded from the following location: www.arubanetworks.com/safety_addendum.The device will be electronically labeled and the FCC ID will be displayed via the controller Web UI under the About menu.EMC Compliance and Warning StatementIEC 60601-1-2: 2007 EN 60601-1-2: 2007 This equipment has been tested and found to comply with the limits of the standard for medical devices, IEC 60601-1-2:2007. The unit also complies with the requirements of EN 60601-1-2:2007, providing the presumption of compliance to the European Union’s Medical Device Directive 2007/47/EC. The limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the manufacturer’s instructions may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes interference with other devices, which may be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:Reorient or relocate the device receiving the interference.Increase the separation between the equipment.Connect the equipment into an outlet on a circuit different from that to which the other device(s) are connected.Consult the manufacturer or field service technician for help.The Model IAP-105 does not have an Applied Part as defined in IEC 60601-1. The protection against electric shock is Class ll. Device is not protected against ingress of liquids and has a protection class of IPX0 as defined by IEC 60601-1 and IEC 60529. Equipment not suitable for use in the presence of flammable mixtures.The unit is considered “Continuous Operation” equipment as defined by IEC 60601-1. Power Consumption – 48 VDC 802.3af power over Ethernet or 12VDC, 1.25A for external AC supplied power (adapter sold separately); Maximum power consumption – 12.5W. Mechanical Dimensions: 132mm x 135mm x 45mm; 300g.Environmental: Operating Temp: 0° C to +50° C (+32° F to +122° F); Humidity: 5 to 95% non-condensing. Storage Temp: -40° CS to +70° C (-40°F to +158°F).If both POE and DC power are available, the IAP uses POE even when there is not enough POE voltage available to power the IAP.Table 1  IAP-105 Series LED MeaningsLED Color/State MeaningPWR Off No power to IAPGreen flashing System initializingRed steady System failed to initialize, contact TACGreen steady Power on, device readyENET(10/100/1000 Mbps)Off No linkGreen on 1000 Mbps linkAmber on 10/100 Mbps linkGreen flashing Ethernet link activity11A/N Off 5 GHz radio is disabledAmber  5 GHz radio enabled in WLAN modeGreen 5 GHz radio enabled in 11n modeGreen flashing 5 GHz Air Monitor or RF Protect mode1000Base-T Gigabit Ethernet PortRJ-45 FemalePin-OutSignal Name12345678BI_DC+BI_DC-BI_DD+BI_DD-BI_DA+BI_DA-BI_DB+BI_DB-FunctionBi-directional pair +CBi-directional pair -CBi-directional pair +DBi-directional pair -DBi-directional pair +ABi-directional pair -ABi-directional pair +BBi-directional pair -B     SerialConsole Port12345678TxDGNDRxDRJ-45 FemalePin-OutDirectionInputOutputGND3452563RJ-45 DB-9InternalConnectionsTxDGNDRxD12345678TxDGNDRxDRJ-45 FemalePin-OutDirectionInputOutputDB-9 MalePin-OutTxDRxDGround543219876DirectionInputOutput11B/G/N Off 2.4 GHz radio disabledAmber  2.4 GHz radio enabled in WLAN modeGreen 2.4 GHz radio enabled in 11n modeGreen flashing 2.4 GHz Air Monitor or RF Protect modeIf a power adapter other than the one provided by Aruba Networks is used in the US or Canada, it should be cULus (NRTL) Listed, with an output rated 12 VDC, minimum 1.25A, marked “LPS” or “Class 2,” and suitable for plugging into a standard power receptacle in the US and Canada.Table 1  IAP-105 Series LED MeaningsLED Color/State Meaning10!RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 13.78 inches (35 cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems.

Navigation menu