HON HAI PRECISION IND T07AW Wireless Router for ADSL User Manual

HON HAI Precision Ind. Co., Ltd. Wireless Router for ADSL Users Manual

Contents

Users Manual

                   REV. 0.01Engineering RequirementSpecification of T07L022.00Prepared by Reviewed by Approved byHumphrey Huang
                   REV. 0.02Contents0. Revision History ......................................................................................................... 31. Introduction ................................................................................................................. 41.1 Referenced Documents ....................................................................................42. Hardware Requirements........................................................................................... 52.1 Overall Information .........................................................................................52.2 Detailed HW Information ................................................................................52.2.1 Generic assumptions........................................................................52.2.2 ADSL requirements...........................................................................62.2.3 Ethernet interface requirements .....................................................72.2.4 Wireless interface requirements .....................................................72.2.5 LEDs....................................................................................................83. Software Requirements ............................................................................................ 94. Regulatory requirements .......................................................................................... 9
                   REV. 0.030. Revision HistoryDate Revision Comment2005/01/18 0.0 Initial released
                   REV. 0.041. IntroductionProject Name: T07L022.00This documentation describes the Engineering Requirement Specification(ERS) of the ADSL CPE with four Ethernet interfaces and a Wirelessinterface using BRCM BCM6348 solution.1.1 Referenced Documents[1]  Specifications for Next-Generation xDSL Broadband Access Network,       Chunghwa Telecom Co., Ltd.
                   REV. 0.052. Hardware Requirements2.1 Overall InformationT07L022.00 for CHT 6th tender ADSL2+ CPE Four-port Ethernet MiniPCI interface for 802.11g WLAN2.2 Detailed HW Information2.2.1 Generic assumptions  ADSL: BCM6348 Ethernet Switch: BCM5325E SDRAM: 16MB - (4M*16) * 2 pcs Flash: 4MB WLAN Interface: MiniPCI Standalone POTS Splitter/ Low-pass Filter
                   REV. 0.062.2.2 ADSL requirements  Standard: ITU-T G.992.5 (ADSL2+) ADSL physical performance requirements:
                   REV. 0.072.2.3 Ethernet interface requirements The ATU-R shall provide four 10/100 Base-T auto-sensing and half/full duplexconfigurable Ethernet interfaces. The Ethernet interfaces for ATU-R shall beable to operate well simultaneously. The 10/100 Base-T Ethernet interfaceshall comply with the IEEE 802.3/IEEE 802.3u, respectively.2.2.4 Wireless interface requirements  Transmitter: Max. output power shall be  ≧ 15mW, 30mW, 60mW, as an option and will be selected in procurement specification. Receiver:
                   REV. 0.082.2.5 LEDsShall provide different status indicators on the front panel.(1) Power,(2) Alarm,(3) LAN Connectivity for each LAN port,(4) LAN Data Transmit/Receive for each LAN port,(5) Line Synchronization, including retraining phase and in-synchronization,(6) Line interface Data Transmit/Receive,(7) Wireless Connectivity and Data Transmit/Receive.
                   REV. 0.093. Software Requirements   Follow the requirements of [1].4. Regulatory requirements Suitable protection devices in compliance with IEC 61000-4-5 class 3 atleast or FCC part 68 shall be provided on the line interfaces, the POTSsplitter/ Low-pass filter, and AC power supply lines to safeguard the unitagainst the damage due to transient and lightning surge voltage presentedon the telephone line and AC power supply line. The test results of IEC61000-4-5 can be temporary degradation or loss of function orperformance but must be self-recoverable and pass operationally within 10minutes. To fulfill surge protection in easy-installation manner, the ATU-Rmust incorporate with chassis grounding mechanism on the exterior ofdevice. The electromagnetic compatibility requirements of the ATU-R shall complywith class A of EN55022 of the CENELEC (the European Committee forElectrotechnical Standardization), or class A of 22 of the CISPR(International Special Committee on Radio Interference of the InternationalElectrotechnical Commission) or class A of Subpart B of Part 15 of theFCC (Federal Communications Commission) rules of U.S.A.
                   REV. 0.0   1           Engineering Requirement Specification  of T07L022.01        Prepared by  Reviewed by  Approved by Devin Shyr  Humphrey Huang
                   REV. 0.0   2 Contents  0. Revision History....................................................................................................3 1. Introduction .................................................................................................................4 1.1 Referenced Documents....................................................................................4 2. Hardware Requirements...........................................................................................5 2.1 Overall Information .........................................................................................5 2.2 Detailed HW Information ................................................................................5 2.2.1 Generic assumptions........................................................................5 2.2.2 ADSL requirements...........................................................................6 2.2.3 Ethernet interface requirements......................................................7 2.2.4 LEDs....................................................................................................7 3. Software Requirements ............................................................................................8 4. Regulatory requirements ..........................................................................................8
                   REV. 0.0   3 0. Revision History  Date Revision  Comment 2005/07/19 0.0  Initial released
                   REV. 0.0   4 1. Introduction Project Name: T07L022.01  This documentation describes the Engineering Requirement Specification (ERS) of the ADSL CPE with four Ethernet interfaces.   1.1 Referenced Documents [1]  Specifications for Next-Generation xDSL Broadband Access Network,         Chunghwa Telecom Co., Ltd.
                   REV. 0.0   5 2. Hardware Requirements  2.1 Overall Information T07L022.01 for CHT 6th tender  ADSL2+ CPE  Four-port Ethernet  2.2 Detailed HW Information 2.2.1 Generic assumptions    ADSL: BCM6348  Ethernet Switch: BCM5325E  SDRAM: 16MB - (4M*16) * 1 pcs  Flash: 2MB  Standalone POTS Splitter/ Low-pass Filter
                   REV. 0.0   6 2.2.2 ADSL requirements    Standard: ITU-T G.992.5 (ADSL2+)  ADSL physical performance requirements:
                   REV. 0.0   7 2.2.3 Ethernet interface requirements   The ATU-R shall provide four 10/100 Base-T auto-sensing and half/full duplex configurable Ethernet interfaces. The Ethernet interfaces for ATU-R shall be able to operate well simultaneously. The 10/100 Base-T Ethernet interface shall comply with the IEEE 802.3/IEEE 802.3u, respectively.    2.2.4 LEDs Shall provide different status indicators on the front panel. (1) Power, (2) Alarm, (3) LAN Connectivity for each LAN port, (4) LAN Data Transmit/Receive for each LAN port, (5) Line Synchronization, including retraining phase and in-synchronization, (6) Line interface Data Transmit/Receive,
                   REV. 0.0   8 3. Software Requirements    Follow the requirements of [1].   4. Regulatory requirements  Suitable protection devices in compliance with IEC 61000-4-5 class 3 at least or FCC part 68 shall be provided on the line interfaces, the POTS splitter/ Low-pass filter, and AC power supply lines to safeguard the unit against the damage due to transient and lightning surge voltage presented on the telephone line and AC power supply line. The test results of IEC 61000-4-5 can be temporary degradation or loss of function or performance but must be self-recoverable and pass operationally within 10 minutes. To fulfill surge protection in easy-installation manner, the ATU-R must incorporate with chassis grounding mechanism on the exterior of device.   The electromagnetic compatibility requirements of the ATU-R shall comply with class A of EN55022 of the CENELEC (the European Committee for Electrotechnical Standardization), or class A of 22 of the CISPR (International Special Committee on Radio Interference of the International Electrotechnical Commission) or class A of Subpart B of Part 15 of the FCC (Federal Communications Commission) rules of U.S.A.