HID Global 537Y Identification Proximity Reader User Manual

HID Global Corporation Identification Proximity Reader

User manual

__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page iInstallation Manual - 5375-900 Rev 06MaxiProx Reader 5375A
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page iiCONTENTSCHAPTER 1 MAXIPROX SYSTEM OVERVIEW ............................................................................................................11.1 OPERATION......................................................................................................................................................................11.2 PARTS LIST ......................................................................................................................................................................11.3 REGULATORY APPROVALS AND CERTIFICATIONS ............................................................................................................1CHAPTER 2 INSTALLATION PROCEDURE...................................................................................................................22.1 PREPARATION..................................................................................................................................................................22.2 MOUNTING AND INSTALLATION .......................................................................................................................................22.3 MOUNTING APPLICATIONS...............................................................................................................................................22.4 CABLE PREPARATION ......................................................................................................................................................22.5 INSTALL CABLE ...............................................................................................................................................................22.6 CABLE NOTES..................................................................................................................................................................22.7 CABLE CONNECTIONS......................................................................................................................................................32.8 DIPSWITCH AND JUMPER SETTINGS .................................................................................................................................42.9 TAMPER SWITCH .............................................................................................................................................................52.10 MOUNTING ......................................................................................................................................................................52.11 POWER SUPPLY................................................................................................................................................................62.12 AUTOTUNE OPERATION ...................................................................................................................................................62.13 READER TESTING ............................................................................................................................................................62.14 POWER-UP TUNE.............................................................................................................................................................62.15 PERIODIC AUTOTUNE.......................................................................................................................................................62.16 SUPERVISOR MODE .........................................................................................................................................................62.17 INSTALL COVER...............................................................................................................................................................6CHAPTER 3 INSTALLATION NOTES AND GUIDELINES ...........................................................................................93.1 POWER SUPPLY................................................................................................................................................................93.2 INSTALLATION NEAR METAL ...........................................................................................................................................93.3 RADIO FREQUENCY INTERFERENCE.................................................................................................................................93.4 TRANSPONDER TYPES ...................................................................................................................................................10CHAPTER 4 APPLICATION NOTES ...............................................................................................................................114.1 WIEGAND INTERFACE DESCRIPTION ..............................................................................................................................114.1.1 Wiegand Message Format ....................................................................................................................................114.1.2 Output Specification .............................................................................................................................................114.1.3 Signal Levels.........................................................................................................................................................124.1.4 Data Pulses...........................................................................................................................................................124.1.5 Example Output ....................................................................................................................................................124.2 CLOCK AND DATA INTERFACE DESCRIPTION.................................................................................................................134.2.1 Clock and Data Message Format .........................................................................................................................134.2.2 Data Timing..........................................................................................................................................................134.2.3 Output signal Levels .............................................................................................................................................144.2.4 Bit structure..........................................................................................................................................................144.2.5 Bit Stream .............................................................................................................................................................154.2.6 Output Specification .............................................................................................................................................164.3 RS232/RS422 CARD MESSAGE SPECIFICATION (SEND MODE ONLY) ...........................................................................16
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page iiiFIGURESFIGURE 1:  MAXIPROX FRONT VIEW ...............................................................................................................................................7FIGURE 2:  MAXIPROX INSIDE VIEW SHOWING MOUNTING HOLE LOCATIONS ...................................................................................8FIGURE 3:  DATA PULSES - TIMING PARAMETERS .........................................................................................................................12FIGURE 4:  DATA TIMING - TIMING CHART....................................................................................................................................14TABLESTABLE 1:  TB1 CONNECTOR DEFINITION ........................................................................................................................................3TABLE 2:  TB2 CONNECTOR DEFINITION ........................................................................................................................................3TABLE 3:  DIPSWITCH AND JUMPER SETTINGS ...............................................................................................................................4TABLE 4:  INTERFACE JUMPERS DESCRIPTION - P3 AND P4.............................................................................................................4TABLE 5:  SWITCH DESCRIPTION - SW2..........................................................................................................................................4TABLE 6:  MODE CHART .................................................................................................................................................................4TABLE 7:  BAUD RATE CHART – RS232 AND RS422 ......................................................................................................................4TABLE 8:  SWITCH DESCRIPTION - SW5..........................................................................................................................................5TABLE 9:  LOGIC LEVELS ..............................................................................................................................................................12
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 1Chapter 1  MaxiProx System OverviewThe MaxiProx Reader is a self-contained proximity Reader.  The two piece polycarbonate enclosure has anO-ring that weather seals the enclosure pieces together and a cable fitting that seals the cable entry.  Thewater-resistant unit is designed for outdoor use.  The enclosure is mountable on a single gang electrical box.A bi-color LED and audible tone provide user feedback. Configurable open collector data outputs providethe data to the Host.  Configurable DIPswitches and jumpers provide choice of data interfaces betweenWiegand, Clock and Data, RS 232 and RS422.  The data interface is configured as ordered from the factory,but can be changed in the field - please contact HID Technical Support for assistance.  A tamper switch canalert the Host when the enclosure is opened.  Internal DIP switches and jumpers provide for configuration ofthe outputs, audible tone and LED control options.  Installation of the MaxiProx Reader consists ofmounting, connecting the cable to the Host and +12VDC or +24VDC power, verifying the DIPswitch andjumper settings, verifying Autotune, and verifying the reading of a transponder.1.1 1.1 1.1 1.1  OperationOperationOperationOperationTransponders (Proximity Cards or ProxKeys) are presented to the front of the MaxiProx. The LED is redwhen ready to read a transponder. The LED turns green and the beeper sounds when the transponder is readand the message is transmitted to the Host computer or interface panel. The system is ready for anothertransponder as soon as the LED returns to red. There is an anti-passback delay of about one and a halfseconds before it will read the same card. The LED flash is typically 250 milliseconds long. The operation ofthe LED and beeper may be controlled by the Host, in which case the actual operation will depend on theprogrammed timing of the Host.1.2 1.2 1.2 1.2  Parts ListParts ListParts ListParts List1. MaxiProx Reader Qty 1 (included)2. Installation Manual Qty 1 (included)3. Cable Fitting Qty 1 (included)4. Label for front cover - HID logo Qty 1 (included)5. #6-32 x 1" flat head screw, for upper-left base mount screw Qty 1 (included)6. #6-32 x 1" black screw, for gang-box mounting Qty 2 (included)7. #6-32 x .75" flat head screw, for front cover mounting Qty 1 (included)8. Cable, 5 conductor, 22 AWG  (Alpha 1295 C or equivalent) See cable notes9. Power Supply – 2.0 A linear regulated +24VDC, nominal (+21 to +28.5VDC)Factory Default – No P2 Shunt Jumper10. +12VDC Shunt Jumper – P2-1 to P2-2 for 12VDC operation +12VDC, nominal (+11VDC to +20VDC)1.3 1.3 1.3 1.3  Regulatory Approvals and CertificationsRegulatory Approvals and CertificationsRegulatory Approvals and CertificationsRegulatory Approvals and Certifications Underwriters Laboratories listing FCC Certification Foreign Countries EMC and/or Type Approvals CE Mark European Declaration of Conformity
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 2Chapter 2  Installation Procedure2.1 2.1 2.1 2.1  PreparationPreparationPreparationPreparationDetermine an appropriate mounting position for the MaxiProx. Install an electrical box or drill theappropriate mounting holes from inside the base with the cover removed for #6 fasteners. For optimumperformance, the Reader should be mounted at least 4 inches away from any metallic surface 12-inch x 12-inch or larger. The Autotune feature automatically compensates for incidental metal such as aluminum studsand conduit. The best method for installing the MaxiProx is by mounting the back of the Reader to themounting surface. Side mounting is usually accomplished with an adapter or spacer (customer supplied) thatmounts to the back of the Reader.2.2 2.2 2.2 2.2  Mounting and InstallationMounting and InstallationMounting and InstallationMounting and Installation When fastening the MaxiProx to the mounting surface, do not use a metallic fastener larger than a #6screw. Avoid mounting the MaxiProx closer than 1 meter (40-inches) to another MaxiProx.2.3 2.3 2.3 2.3  Mounting ApplicationsMounting ApplicationsMounting ApplicationsMounting Applications The MaxiProx may be mounted to a gooseneck that is 1½-inch in diameter with a 4-inch diameter-mounting flange without degradation of read range. The flange should be mounted to a non-metallicadapter that will ease the installation of the MaxiProx to the flange. The read range will not be affected. The MaxiProx may be mounted to a 12-inch x 12-inch or larger metal plate with a 4-inch spacer used toseparate the Reader from the plate. Acrylic, Plexiglas, Lexan (polycarbonate) or other suitable plastics may be found in ½-inch to 1-inchstock. Mounting adapters may be fabricated from these materials that would be sturdy and not affect theperformance of the MaxiProx.  Plastic J-boxes can also be used.2.4 2.4 2.4 2.4  Cable PreparationCable PreparationCable PreparationCable PreparationPrepare the cable by cutting the cable jacket back 2 inches and strip the wires 1/4-inch. Tinning the wires isnot required.2.5 2.5 2.5 2.5  Install CableInstall CableInstall CableInstall CableRoute the interface cable from the MaxiProx to the Host.  Connect the MaxiProx DC power input to the Hostor external power supply. Either +12VDC or +24VDC can be used.CAUTION!The shunt jumper P2 is not installed as the factory default for +24VDC operation.  If the jumper is in the +12VDC position and +21 to +28.5 VDC is applied, circuit damage can result.2.6 2.6 2.6 2.6  Cable NotesCable NotesCable NotesCable Notes For Wiegand interface cable the maximum length is 500 feet (150m), 50 feet (15m) for RS232, and 4000feet (1200m) for RS422. When using 5 conductor cable, the power supply and Host must have a common ground (voltagereference).
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 3 7-Conductor cable is required when using the Hold function or if the ground for the MaxiProx's powersupply is not common with the ground of the Host. TB2 terminal 3, Data Return, is to be connected to theground of the Host. (Alpha 1296 C or equivalent). 7-Conductor cable is required when the Hold function is used, and the power supply and Host "ground"are separate. (Alpha 1297 C or equivalent). A 22 AWG twisted pair, shielded, stranded cable (Belden 9330 or equivalent) is often required for thetamper switch. Follow the recommendations of the manufacturer of the Host system. If the tamper input isa supervised input, the "end-of-line" resistor may be mounted in the enclosure between TB1-4 and TB1-5. The inner diameter of the cable fitting will accommodate a cable with an outer diameter of up to .260-inches.2.7 2.7 2.7 2.7  Cable ConnectionsCable ConnectionsCable ConnectionsCable ConnectionsInstall the cable fitting on the rear of the MaxiProx. Feed the cable through the cable fitting. Connect thewires to the terminal strip with the minimum length necessary. Do not leave extra loops of wire inside theReader housing. Connect the Reader to the Host according to the terminal descriptions in the dimensiondiagram. Tighten the fitting to secure the cable. Connect the drain line of the shield to terminal TB1 Pin 2(Power Supply Shield). If it is bare, cover it with heat shrink or tape to avoid short circuits to the other wires.The opposite end of the drain line should be connected to the negative terminal and the frame connection ofthe power supply.CAUTION!The shunt jumper P2 is not installed as the factory default for +24VDC operation.  If the jumper is in the +12VDC position and +21 to +28.5 VDC is applied, circuit damage can result.Table 1:  TB1 Connector Definition12345+DC Shield Ground Ground TamperCommon TamperSelectRed Drain Black --- ---Table 2:  TB2 Connector Definition123456789DATA 0DATA/TD/RX+DATA 1CLK/RD/RX- DATA RTN GREEN LED RED LED BEEPER HOLD/CARD PRESENT TX+RS422 TX-RS422Green White Orange Brown Yellow BlueNoteOn TB2, pins 1, 2 and 7 have multiple purposes, depending on the interface that the Reader is configured for.In the table above, the first description is for Wiegand, the second for Clock and Data, the third for RS232, andthe fourth is for RS422.
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 42.8 2.8 2.8 2.8    DipSwitch and Jumper Settings  DipSwitch and Jumper Settings  DipSwitch and Jumper Settings  DipSwitch and Jumper SettingsVerify the default settings according to the model ordered, or set the DIPswitches and Jumper positionsaccording to the following.Table 3:  DIPSwitch and Jumper SettingsSwitch Default Description1. Interface mode 1 On See mode chart table 6 below2. Interface mode 2 On See mode chart table 6 below3. Interface mode 3 On See mode chart table 6 below4. Beeper control On/Off On On - beep after valid card read.  Off - no beep after valid card read.5. Green LED flash Off Off - flash after valid card read.  On - no flash after valid card read.6. Single/Dual external LED Off Off - single line LED control.  On - dual line LED control.7. Serial Baud 1 control Off See baud rate chart below.8. Serial Baud 2 control Off See Baud rate chart below.Table 4:  Interface Jumpers Description - P3 and P4P3 and P4 1-2 See mode chart table 6 belowTable 5:  Switch Description - SW2Switch Default Description1. Serial Baud 3 control On See baud rate table 7 below2. Note address 0 N/A Unused3. Note address 1 N/A Unused4. Note address 2 N/A Unused5. Note address 3 N/A Unused6. Note address 4 N/A Unused7. Unused8. UnusedTable 6:  Mode ChartMode SW1-1 SW1-2 SW1-3 SW5-3 SW5-4 SW5-5 P3 & P4JumpersWiegand ON ON ON NA NA NA 1-2Clock & Data OFF ON ON NA NA NA 1-2RS232 ON OFF ON NA OFF OFF 2-3RS422terminated OFF OFF ON ON OFF OFF 2-3RS422unterm. OFF OFF ON OFF OFF OFF 2-3Table 7:  Baud Rate Chart – RS232 and RS422BAUD SW1-7 SW1-8 SW2-19600 ON ON ON4800 OFF ON ON2400 ON OFF ON1200 OFF OFF ON
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 5Table 8:  Switch Description - SW5Switch Default Description1. Data Isolation 1 On See 1 below2. Data Isolation 0 On See 1 below3. RS422 Terminating Resistor On See 5 below4. Serial Hardware line setting 1 Off See 6 below5. Serial Hardware line setting 2 Off See 7 below 1. Open Collector Data Outputs SW5-1&2 when using Wiegand or Clock & Data Interface.  The dataoutputs may be configured so the MaxiProx is electrically isolated from the Host pull-up resistors.  Thedefault (standard) configuration is non-isolated outputs, switches SW5-1 & 2 are ON.NoteWhen the outputs are configured as isolated, separate power supplies should be used for the MaxiProx andHost.  These switches are unused when in RS232 or RS422 mode. 3. Beeper Control SW1-4: The on-board beeper may be enabled or disabled. When enabled, the beepertone is sounded when the LED is green.  SW1-4 in the ON position enables the beeper (the default). 2. LED Control SW1-5: The LED flash after valid card read can be controlled by both the MaxiProx andHost, or Host only.  SW1-5 in the OFF position selects flash green after valid card read (the default). 4. LED Mode SW1-6: Single/Dual Mode. With SW1-6 OFF (default) it is in Single Mode. The LED isnormally red, until internal or host control turns it green (only a single control line is necessary). If ON, itis in Dual Mode, and the LED is normally off (two control lines are necessary for host control of red andgreen). 5. SW5-3 Terminating Resistor: Some RS422 connections require that the RX- line be terminated witha resistor to RX+.  If SW5-3 is in the OFF position, there is no terminating resistor on RX-. If SW5-3 isON, then a 120-ohm resistor is connected between RX+ and RX-. 6. SW5-4 Line Setting 1: SW5-4 is used to configure the Reader's interface configuration. SW5-4 shouldbe in the OFF position for RS232 or RS422 operation. 7. SW5-5 Line Setting 2: SW5-5 is used to configure the Reader's interface configuration. SW5-5 shouldbe in the OFF position for RS232 or RS422 operation.2.9 2.9 2.9 2.9  Tamper SwitchTamper SwitchTamper SwitchTamper SwitchConnect the tamper switch to the Host, if provided by the Host.  When the cover is removed, the tamperswitch is released.  The switch contacts available on TB1 Pins 4 and 5 and are either "normally open" or"normally closed" dependent upon the position of the jumper on P1.  Install the jumper to connect pins 1 and2 if you need the "normally open" contacts. Select the 2-3 position if you need the "normally closed"contacts.  "Normally closed" refers to the condition of the switch when the case is open. The contacts arerated for 50 mA at 30 VDC.2.10 2.10 2.10 2.10  MountingMountingMountingMountingMount the base of the MaxiProx that holds the electronics to the surface using the holes located on the baseof the Reader. There are 12 recessed holes for mounting. The holes are not through holes and require drillingbefore mounting. Chose the appropriate holes to be used and drill with a 5/32 (.156) inch bit. Use #6 screwsonly.  (See figure 2).
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 62.11 2.11 2.11 2.11  Power SupplyPower SupplyPower SupplyPower SupplyThe MaxiProx Reader can be operated over the full range of 11-28.5VDC.  Current requirements are 200mA average and 700 mA peak at 12 VDC input.  At 24 VDC (21 to 28.5 VDC) input the average current is260 mA and peak is 1.2 A.  A linear regulated supply rated at 2.0 A is recommended. Noise from devicessuch as switching power supplies, computer monitors, and arc welders can reduce the read range or make theunit inoperable.  Keep these devices at least 10 ft away from the Reader.  With the MaxiProx and powersupply wired together, apply power to the Reader.CAUTION!The shunt jumper P2 is not installed as the factory default for +24VDC operation.  If the jumper is in the +12VDC position and +21 to +28.5 VDC is applied, circuit damage can result.2.12 2.12 2.12 2.12  Autotune OperationAutotune OperationAutotune OperationAutotune OperationThe MaxiProx is tuned correctly when the autotune LED is green.  If the LED is red, use a spacer toposition the Reader at minimum of 4 inches away from metal in the mounting surface.2.13 2.13 2.13 2.13   Reader Testing Reader Testing Reader Testing Reader TestingApply Power to the Reader and the LED will display a sequence of flashes and beeps, indicating the LEDcontrol mode.  Two flashes of green and two beeps followed by a short delay, then one additional flash(beep), is the correct sequence for "Green Flash/Beep on valid read” (SW1-5 off).  Three initial green flashesand beeps followed by a pause and then one additional beep indicate no Green Flash/Beep on valid read(SW1-5 on).2.14 2.14 2.14 2.14  Power-Up TunePower-Up TunePower-Up TunePower-Up TuneFollowing this initial power up sequence the Reader will perform power-up Autotune.  It will beep and turnthe access LED amber for ~1 second to indicate that a power-up tune test is about to begin.  It will thenattempt to tune.  If it successfully tunes, it will give two quick beeps and a green on the access and tuneLED's to indicate the Reader is tuned.  If unsuccessful, the unit will give a single 1.5-second beep with a redon the access and tune LED’s.  If Autotune is not successful, the installer should check for large areas ofmetal less than 4 inches from the back of the unit.2.15 2.15 2.15 2.15  Periodic AutotunePeriodic AutotunePeriodic AutotunePeriodic AutotunePeriodic Autotune retunes every 1 minute.2.16 2.16 2.16 2.16  Supervisor ModeSupervisor ModeSupervisor ModeSupervisor ModeDuring idle periods in normal operation, a periodic supervisor 1 byte transmission is sent to the hostcontroller over the Wiegand interface every 1 minute.  Supervisor Mode is only available in WiegandInterface Mode.2.17 2.17 2.17 2.17  Install CoverInstall CoverInstall CoverInstall CoverReplace the top cover and top cover screw. Make sure that the autotune indicator LED remains in a steadygreen state. If the LED is red, remove the cover and re-mount the unit using a non-metallic spacer to positionit further away from the mounting surface. Reinstall the cover, verify autotune, and install the front label overthe top cover screw and the autotune indicator lens.
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 7Figure 1:  MaxiProx Front View
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 8Figure 2:  MaxiProx interior view showing mounting hole locations
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 9Chapter 3  Installation Notes and Guidelines3.1 3.1 3.1 3.1  Power SupplyPower SupplyPower SupplyPower SupplyThe recommended power supply is 12 or 24VDC, nominal, 2.0A current rating, linear regulated.  TheMaxiProx cycles through varying power stages and has a peak current demand of approximately 1.2A whenin long range read mode.  Average current consumption is about 260mA. Failure to provide an adequatecurrent capacity power supply will result in reduced read range.CAUTION!The shunt jumper P2 is not installed as the factory default for +24VDC operation.  If the jumper is in the +12VDC position and +21 to +28.5 VDC is applied, circuit damage can result.The use of a Power Switching Supply is not recommended for two reasons:(1) This type of supply does not provide adequate response to rapid transient current loads and alsogenerates radio frequency (RF) interference in the same band that the Reader receives data and;(2) The power supply may generate noise that is large enough to be transmitted or conducted to theMaxiProx that interferes with the reception of a card signal. Some switching power supplies are not ableto provide adequate regulation to the MaxiProx Reader.3.2 3.2 3.2 3.2  Installation near MetalInstallation near MetalInstallation near MetalInstallation near MetalRead range will be reduced if located on metal surfaces or in the vicinity of metal objects. The amount ofreduction will be a factor of the amount of metal and the distance the Reader is from the metal. Metal nearthe Reader absorbs energy from the Reader excite field and affects the signal being received from the card byre-directing excite field transmissions into the receiver circuitry. Moving the Reader away from the metalobjects reduces energy loss.Try to limit the amount of metallic materials installed near the MaxiProx. Use a plastic electrical box ifpossible. Avoid installing conduit and other metal hardware within 2-inches of the back of the Reader orcloser than 4-inches from large metal surfaces. The typical read distance specification (24-29 inches at 21-28.5 VDC or 21-26 inches at 12 VDC) refers to operation without metal in the vicinity of the Reader. Theread distance will be reduced if metal is installed nearby.The MaxiProx generates a magnetic field on all sides of the Reader. Any metal that conducts electricity,especially metal that contains iron, steel or copper will interfere with the field and reduce the effective readrange (this will happen even if the metal is behind the Reader). It helps to put a non-metallic spacer betweenthe Reader and the metal object.3.3 3.3 3.3 3.3  Radio Frequency InterferenceRadio Frequency InterferenceRadio Frequency InterferenceRadio Frequency InterferenceMotors and electronic devices generate RF noise that may interfere with the reception of the signal from atransponder. The affect of RF noise is typically a reduction of read range. The MaxiProx is susceptible to RFinterference, as are all devices that receive RF signals. The read range is affected by the amount ofinterference (noise) in the area. Common sources of RF interference are power supplies, electrical andelectronic equipment, some types of lighting, computers and monitors, motors and generators. Moving theReader to a location known to be free of interference and testing read range there will help to isolate RFinterference as a factor in low read range situations.
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 10The MaxiProx should not be mounted within six feet of any monitors (VDTs or CRTs) because the scanfrequencies of most monitors include frequencies that may interfere with the signal received from the accesscontrol cards.3.4 3.4 3.4 3.4  Transponder TypesTransponder TypesTransponder TypesTransponder TypesThe type of transponder used affects the read range of the MaxiProx. The various styles of HID cards andtransponders use different types of antennas. The antenna type will determine the read range for that type oftransponder. The Vehicle ID tag provides the longest read range at 32-36 inches; the ProxCard II is 24-29inches. The IsoProx/DuoProx is 17-20 inches. The ProxKey reads at a distance of 15-17 inches.NoteThe above are recommended installation procedures.  All local, state and national electrical codes haveprecedence.
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 11Chapter 4  Application Notes4.1 4.1 4.1 4.1  Wiegand Interface DescriptionWiegand Interface DescriptionWiegand Interface DescriptionWiegand Interface Description4.1.1  Wiegand Message FormatIn the Wiegand format, the ID card is programmed with a specific bit pattern and the Reader acquires thedata, checks the customer code and generally sends out the same bit pattern as previously programmed onthe card. Consult factory for variations to this method. A 26 bit Wiegand format will be used in the examplesbelow.The 26 bits of transmission from the Reader to the panel consists of two parity bits and 24 code bits.  Thebits are transmitted in the order described.  The first bit transmitted is the first parity bit, P1; it is even paritycalculated over the first 12 code bits.  The last bit transmitted is the second parity bit, P2; it is odd paritycalculated over the last 12 code bits:Code Format1111111111222222212345678901234567890123456P1CCCCCCCCCCCCCCCCCCCCCCCCP2Parity Format1111111111222222212345678901234567890123456P1EEEEEEEEEEEEOOOOOOOOOOOOP2 P1: First, or even parity bit C: Code bits P2: Second, or odd parity bit E: Bits for calculation of even parity O: Bits for calculation of odd parityData format within the 24 code bits which includes the portioning of the bit, the designation of the MostSignificant Bit (MSB) or the Least Significant Bit (LSB) shall be subject to definition by the panel andReader manufacturers and may remain proprietary.4.1.2  Output SpecificationThe specifications of voltage, current, power and timing are from the perspective of the Reader.  A commonsignal ground is defined as a voltage reference that is common to both the Reader and the control panel.  Thevoltages for the data outputs are referenced from the power supply ground located at the Reader.  Thevoltage measured for the power to the Reader is referenced from the power supply-return connection locationat the Reader, not at the source of the power.
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 12The voltage, current, and timing of the data pulses are measured at the Reader in reference to the powersupply/signal ground at the Reader.  The voltage, current and timing of a signal driving an auxiliary inputdevice on a Reader is measured at the control panel that is controlling the input device (with reference to thesignal ground at the panel).4.1.3  Signal LevelsThe Data One, Data Zero, and LED Control conductors connect signals between the Reader and the panel.The logic levels are defined as follows:Table 9:  Logic LevelsVoltage Data Outputs (Data0 and Data1) Control Inputs (LED’s, Hold, Beeper)Levels Minimum Maximum Minimum MaximumVoh 3.5V 5.5V 3.5V 5.5VVol 0.0V 0.5V 0.0V 0.5VIoh 0.0mA 5.0mA -1.0mA 0.0mAIol -25.0mA 0.0mA 0.0mA 25.0mA4.1.4  Data PulsesThe Data One and Data Zero signals are normally held at a logic high level until the Reader is ready to senda data stream.  The Reader places asynchronous low pulses on the appropriate data lines to transmit the datastream to the panel.  The following timing parameters shall be observed:Figure 3:  Data Pulses - Timing Parameters Tpw Pulse Width Time - 30uS (minimum) to 50uS (maximum) Tpi Pulse Interval Time - 1.8mS (minimum) to 2.2mS (maximum) 4.1.5 Example OutputThe following is an example of an ID card with the number of “816” decimal, which will be output by theMaxiProx Reader, the number “02004CA0661” hex.Data OneData ZeroTpw TpwTpw TpiTpiVohVohVolVol
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 13NoteThe customer code is never transmitted or displayed.4.2 4.2 4.2 4.2  Clock and Data Interface DescriptionClock and Data Interface DescriptionClock and Data Interface DescriptionClock and Data Interface Description4.2.1  Clock and Data Message FormatThe Clock and Data interface consists of three signals, Card Present, Data and Strobe/Clock.  The interface isa serial data stream, which is controlled with a clock/strobe that indicates when data is valid.  All signals arequiescent high.  Card Present goes low when data is about to be sent and remains low until the whole datastream is completed.  Data is the signal that determines the “ones” and “zeros”.  Strobe/Clock is the signalthat indicates when data is valid for each cycle.The Track 2 message format is a stream of binary bits that are grouped into HEX characters.  The messagestarts with leading zeros, followed by a start sentinel, data, end sentinel, LRC and trailing zeros.  Each HEXcharacter has error correction in the form of a parity bit.  Each character consists of five bits.  The maximumnumber of characters for a magnetic strip card encoded on Track 2 are 40, this product will output less than40 characters.  The data consists only of BCD digits, the remaining HEX digits, A to F, are used for the startand end sentinel, data separators and control.   Only hex B and F are used, A, C D and E are not used.  Themessage will consist of a minimum of 210 bits.The bits of a character are in the order 1248P, where parity is odd over the four bits.  The LRC is the Xoringof the message, starting with the start sentinel and ending with the end sentinel.  The LRC does not includethe parity bits of the characters in the Xoring.   LRC does include its own odd parity bit that covers the fourbits that are the result of the Xoring.<leading zeros><Start Sentinel><data><data>........<data><End sentinel><LRC><trailing zero>Customer code 0,1, 63, 72 and 73 (existing customer codes) cards will be read and output in the Track 2format.  The data on these cards will be packed into the Track 2 format in segments of three bits, so thecharacter does not exceed a BCD seven.4.2.2  Data TimingThe outputs, Card Present, Data and Strobe are low going signals and the following timing chart describesthe timing.sentinel parity paritycustomer code 10 zeros        bit even facility code card number   odd[0 0 0 0 0 0 1] [0 0 0 0 0 0 0 0 0 0] [1] [0] [0 1 1 0 0 1 0 1] [0 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0] [1]|     0     |      2    |     0    |     0    |      4        |      C   |     A     |     0    |     6     |     6       |     1 |Wiegand Output | 0   |      C   |     A     |     0    |     6     |     6       |     1 |Hex code numbers  [     6 |    5 ][    0 |     3 |     3 |     0 ]Decimal conversion  [       101 ][                 0816 ]
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 14Figure 4:  Data Timing - Timing Chart10001110000011110000bit time strobe widthcard presentdataclock/strobe1st valid bitNote: the first 25 bits and trailing bits are zeros, not shown above. bit time = 1.5ms (default) strobe width = bit time/3 (33% of bit time), default = 500us Clock/Strobe is valid 1.5ms (one clock cycle, min) after card present is asserted Data is valid 10us (min) before the negative edge of clock/strobe Card Present returns to the high level 50 ms (max) after the last clock/strobe.The above timing is representative of a magnetic stripe card traveling at 8.9 inches per second. The timing isto be adjustable for cards traveling at 4 inches per second to 20 inches per second.  This relates to bit times of3.3 ms and 666us, respectively.  There are 75 bits per inch on Track 2.4.2.3  Output signal LevelsInputs: low threshold = 0.8 volts high threshold = 3.5 volts4.2.4  Bit structureThe Reader will read an 1849 or compatible chip that is encoded with 44 bits of data.  The data will beprogrammed in accordance with ProxGuard formatting.  The data will be packed into the ABA/ISO Track 2message format in accordance with the following rules based on customer code:Case 1:Customer Code = 0, 1, 63, 72, 73 or other, will have the data output as follows.The output is in the Track 2 character format but the bits are packed in sets of three bits (octal):ccc CCCC    a bcd efg hij klm nop qrs tuv wxy zAB CDE FGH IJKWhere cccCCCC is the customer code, abc...IJK is the programmed data on the card.
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 151248p 1248p 1248p1248p  1248p1248p 1248p1248p1248p1248p 1248p1248p1248p 1248p  1248p  1248p  1248p1248p1248p<B> c000p Ccc0p CCC0p a000p dcb0p gfe0p jih0p mlk0p pon0p srq0p vut0p yxw0p BAz0p  EDC0p HGF0p KJI0p <F><LRC>Case 2:Customer Code = 74 are structured as follows:421  8421      8421 8421 8421 8421 8421 8421  8421 8421 8421CCC CCCC 1 aaaa  bbbb cccc dddd eeee   ffff    gggg hhhh  iiiiCCC CCCC  - Customer code1 - fixed bit “1”aaaa - Most significant nibble of messagebbbb - Second MSNcccc - next  nibblehhhh - least significant nibble of messageiiii - LRC of nibbles aaaa to hhhh, start (B) and end sentinel (F) (xor of the nibbles or the even parity of the respectivecolumn)The output from the Reader will look like the following:1248p 1248p    1248p     1248p     1248p     1248p   1248p    1248p    1248p  1248p 1248p<B> <aaaap> <bbbbp> <ccccp> <ddddp> <eeeep> <ffffp> <ggggp> <hhhhp> <F> <iiiip>start   data a     data b      data c    data d    data e      data f    data g    data h   end   LRCThe message structure follows the ISO/ABA Track 2 standard.  The first character is a start sentinel: B (hex),which is followed by data.  After the data there is an end sentinel: F (hex), followed by an LRC.  The LRC isthe xoring of the message in accordance to the bit position.  Each character has an odd parity bit that coversbit 1 to bit 4 of the nibble.A typical message:B 1 2 3  F LRC the bits broken down:1248p 1248p 1248p 1248p 1248p 1248p11010 10000 01000 11001 11111 00101B         1         2         3         F         4start    <        data             > end     LRC4.2.5  Bit Stream
__________________________________________________________________________________________________________HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA •Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690http://www.hidcorp.com MaxiProx Reader Installation Manual 5375-900 REV 06 Page 16The bit stream will consist of 25 leading zeros, the message and fill with zeros until the end of the message.The message will consist of a minimum of 210 bits.Example00000000000000000000000000 11010 10000 01000  11001  11111  00100 00000000000000...000000                          B        1           2         3         F         LRC4.2.6  Output SpecificationVol = 0.8 VVoh = 3.5 Vsink = 25 masource = 5 ma4.3 4.3 4.3 4.3  RS232 and RS422 Card Message Specification (Send Mode Only)RS232 and RS422 Card Message Specification (Send Mode Only)RS232 and RS422 Card Message Specification (Send Mode Only)RS232 and RS422 Card Message Specification (Send Mode Only)When Access Cards (transponders) are presented to the MaxiProx Reader, the Reader sends a message. Themessage is in the following format:CCDDDDDDDDDDXX<CR><LF>^ First character sentAll characters C, D and X are ASCII encoded, hexadecimal digits. (i.e., the hex value 7 is sent as an ASCIIcharacter 7 or the hex value E is sent as an ASCII character E).The CC field is reserved for use by HID Corporation. The valid values are 00 through 7F.The  DDDDDDDDDD field is the transponders (Access Card) data. The valid values are 0000000000  through1FFFFFFFFF (ASCII).The XX field is a computed checksum. The checksum is calculated by first grouping the message data into thepairs CC DD DD DD DD DD. Each pair of characters represents one byte of data. Then each pair of characters isconverted from ASCII to their respective hex values. At this point, the 6 bytes are added together. Thechecksum is equal to the least significant 8 bits of the result.<CR> is the ASCII code for a carriage return. (0D hex)<LF> is the ASCII code for a line feed. (0A hex)For example, if the MaxiProx reads a transponder (Access Card) that contains the value CC=00 andDDDDDDDDDD=01234ABCDE, the Reader will report the ASCII message 0001234ABCDE08<CR><LF>.Note that each of the characters is ASCII encoded. The actual bytes (hex value) that are sent to the host are:<30><30><30><31><32><33><34><41><42><43><44><45><30><38><0D><0A>The checksum was computed by adding 00 + 01 + 23 + 4A + BC + DE = 208 hex. The checksum is the leastsignificant 8 bits of this result or 08 hex.  The communications settings are 9600-75Hz BAUD, 8 bits, 1 stopbit, no parity.

Navigation menu