Getac Technology EMPT116F Digitizer module User Manual OEM PRODUCT SPECIFICATION

Getac Technology Corporation Digitizer module OEM PRODUCT SPECIFICATION

Contents

User Manual Module

                                                                      EMPEN T116 Sensor SPECIFICATION                                                  Product Name:TF1-DIGITIZER;ASIC,11.6”,F110G4,EMP                 Getac P/N: 412888700007  EMPEN P/N : 20160002  Firmware Version : 18
                                                                Revision History Revision Date Description Author /Revised by 01 2016/11/29 Initial Jesse
                                                                1. Product Specifications 1.1 General Specifications      Technology   Battery free Electro-magnetic   Interface USB VID & PID   VID:0x0458, PID:0x501D Active Area   258.13×146mm   Resolution   0.01mm / 2560 LPI (see Note 5) Coordinate Accuracy   ±0.4mm (see Note 1, 2, 3 and 5)   Coordinate Jitters 1-point max (see Note 1 and 5) Detectable Pen tilt   Up to 50° from vertical (see Note 5) Detectable Height   4 to 14mm above the Sensor Film (see Note 1 and 5)   Position Report Rate   133 PPS ( Pen hover at sensor center ) Pressure Resolution 1024 levels (see Note 4 and 5) EM module Thickness 3.0 mm max Note 1: The EM Sensor Board and Stylus at ordinary temperature. Note 2: The pen held vertically at 0mm high from sensor film. Note 3: See Picture1, the accuracy guaranteed region is 15mm or more inside region   from the active area edge. Note 4: Pressure range is 20g≦200 levels and 650g≦1023 levels Note 5: This function must be used with Getac TF1-DIGITIZER PEN unit Picture1
                                                                1.2 Dimensional Outline of PCBA and Sensor Film    1.3 Electrical Specifications   1.3.1 Circuit Diagram           Signal Assignment USB  CONN TLSC3590ET88 Controller Board      Sensor Film    A CF
                                                                Pin   Name Function 1 NC Not Connect 2 USB- USB- Signal 3 USB+ USB+ Signal 4 NC Not Connect 5 NC Not Connect 6 NC Not Connect 7 VCC +5V Power Supply 8 GND Ground    1.3.2 Test Conditions    Ambient Temperature : 25+/- 5  ℃  Ambient Humidity : 65 +/- 16% ( RH)  Supply Voltage : VDD 5V   Item   Min.   Typ.   Max.   Unit.   Remark   Supply Voltage        4.75 5.0 5.25 V   Current Consumption   Pen in touch 75 80 98 mA     Current Consumption   Pen@10cm 85 90 100 mA  Current Consumption   Standby mode 84 110 124 mA  Low Scan mode 16 (400mSec) 35   125 (130mSec) mA   Keep standby mode 40 min will entry low scan mode
                                                                2. Reliability Test   Item SPEC Testing method Criteria Number of test samples Humidity Test 30℃/95%~61℃/95%, 12 hours for 30℃/95%,   12 hours for 61℃/95%, one cycle is 24 hours , test time is 10days MIL-STD-810G- 507.5 Humidity Procedure – II Aggravated 1. All functions must be normally 2. No oxidation on screws. 3. No visual abnormal. 4. There shall not be any cosmetic damage   5. T/S cannot allow the abnormal status like peel off, bubble . 2 High Temperature Test (Operating) 61℃  96h MIL-STD-810G-501.5 Procedure II Operation 2 High Temperature Test (Non-Operating) 33℃~71℃  ,10days 12 hours for 31℃,   12 hours for 71℃ one cycle is 24 hours,     test time is 10days MIL-STD-810G-501.5 Procedure I 2 Low Temperature Test (Operating) -21℃  96h   MIL-STD-810G-502.5 Procedure II 2 Low Temperature Test (Non-Operating) -40℃  96h   MIL-STD-810G-502.5 Procedure I 2 Drop Test 120cm Wood floors  2 Temperature Shock Test -41℃~71℃  duration 1h, 3cycle ,total:6h MIL-STD-810G-503.5   Procedure-I-C Multi-cycle shock. 2