Gantner Electronic GEA1150002A Access Control Terminal, Access Control Terminal with Biometry User Manual Brochure 6100

Gantner Electronic GmbH Access Control Terminal, Access Control Terminal with Biometry Brochure 6100

Contents

Brochure 6100

Function descriptionThe GAT Access 6100 reads contact-free data carriers and checks and grants authorisations. The user holds the data carrier over the round scan field and selects the required service via the acknowledge key. The integrated 4-segment LED display, monochrome LCD display and acoustic signal indicate authorisation. Further functions:• Activation of turnstiles, doors etc. via relay output• Feedback input• User guidance via monochrome display (LCD), 4-segment LED display,  illuminated round scan field and beeper• Secure data transmission between reader and data carrier• RFID frequency 13.56 MHz• Reading of LEGIC®, MIFARETM standard and ISO 15693 data carriers  (depending on the device type)• Opening of housing only possible with special tool• Plug & Play installationGAT Access 6100Access Control TerminalApplicationThe GAT Access 6100 is a stylish terminal for access control in leisure facilities such as swimming pools, spas and gyms. Identification at the terminal is by contact-free RFID data carrier (Radio Frequency Identification).Information display for user guidance is realised via a graphical mono-chrome display (LCD). The different versions (see order information) give technological flexibility.Description PartNo.GAT Access 6100 BAccess control terminal with monochrome display (LCD)and contact-free reader for LEGIC® data carriers651681GAT Access 6100 FAccess control terminal with monochrome display (LCD)and contact-free reader for MIFARETM data carriers776487GAT Access 6100 ISOAccess control terminal with monochrome display (LCD)and contact-free reader for ISO 15693 data carriers6517821www.gantner.comOrder informationDescription PartNo.GAT Access 6100 ManualOperating and configuration instructions, English332727GAT Reader WKTool to open the reader housing581683AccessoriesValid as from July 30th, 2013 • Technical data subject to modifications without notice! DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279
Nominal voltage: 12/24 VDC (SELV - safety extra-low voltage)Permitted input voltage: 10 to 28 VDCAver. power consumption: 3 WData storage: Internal EEPROM memory for configuring and booking memory, data preservation min. 10 yearsInternal clock: Data preservation approx. 12 h (Gold-Cap)Reader type: See order informationFrequency of reading field: 13.56 MHzControl elements: - 4 function keys- RFID readerDisplay elements: - Full graphics monochrome display (LCD) with white LED background lighting, resolution 128 x 64 pixels, visible area 50 x 25 mm- RFID reader (illuminated)- Acoustic signal- 4-segment LED display with different coloursHost interface: Ethernet 10/100 MBit/sSignal input: 1 x optocoupler (configurable)- Input voltage: 0 to 30 VDC  ULow < 2 VDC, UHigh > 6 VDC- Input current: 4.5 mASignal output: 1 x relay (configurable NO/NC)- Switching voltage: max. 30 VAC/DC- Continuous current: max. 2 A - Switching power: max. 60 VAConnection terminals: 0.5 to 1.5 mm2Housing material: - Upper part: plastic PMMA- Back part: plastic PC-ABSDimensions: 93 x 107 x 33 mmPermitted ambient temperature: -10 to +55°CStorage temperature: -20 to +70°CRelative humidity: 20 to 80%, non-condensingProtection type: IP 54Protection class: IIIWeight: 0.2 kgEnvironment classbased on VDS 2110: II (conditions in indoor areas)2www.gantner.comTechnical data93 mm (3.66”) 33 mm (1.3”)24 mm (0.94”)107 mm (4.2”)234561Typical applicationTurnstileRFID data carriersGAT Access 6100Power supplyNetworkDimensions1. 4-segment LED display2. Monochrome display (LCD)3. Function keys4. Illuminated, round scan field5. Device back part6. Device upper partValid as from July 30th, 2013 • Technical data subject to modifications without notice! DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279
3www.gantner.comValid as from July 30th, 2013 • Technical data subject to modifications without notice! DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279Mounting and installation instructionsThe device back part is secured by screws to a flat background (e.g. concrete wall). When fixing to an uneven background the device back part must not be distorted as this will prevent correct connection of the upper part. Recommended mounting height: top edge of device 1.3 m.Use the drilling template which is attached to the device.Mounting the device upper partOnce the connection cables are terminated, the device back part and upper part are connected together via a connection cable (already connected in the upper part) and the two parts are fixed together.    1.                                                                  2.         Notes:1.  Check the socket in the device back part (circled in figure 1). Dirt, dust and humidity must be removed so that a good contact of the connection cable is guaranteed. No aggressive detergent may be used. Please do not damage socket contacts. Attention: Cleaning only in powerless state.2.  Plug in the connection cable into the socket in the device back part (consider alignment) and clip the top of the device upper part into the device back part.Wall mountingCables can be flush (1) or suface-mounted (2).When surface mounting please check whether the cables can still be inserted once the device back part has been mounted, otherwise run the cables through the cable lead-ins prior to securing.1. Flush-mounted cable2. Surface-mounted cable3. Back box4. Device back part5. Cable conduit for surface cable connection           3.                                            4.3.  Swing down the device upper part until it clicks.4.  The device can only be opened with the supplied special tool! With this the two catches on the bottom of the device can be unlocked in succession.69 mm (2.72”)13 mm (0.51”)18.5 mm (0.73”)28.5 mm (1.12”) 20 mm(0.79”)71 mm (2.8”)60 mm (2.36”)23451
Electrical connectionsTCP/IP with external power supply4www.gantner.comValid as from July 30th, 2013 • Technical data subject to modifications without notice! DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279NetworkEthernet, Connection via screw terminals.Power supplyDC supply (see technical data), e.g. via GANTNER GAT Power SupplySP014/1. The power input is protected against reverse-polarity.Recommended cables:Ethernet: min. CAT 5 (STP) for 100 MBitWire coloursEthernet 10/100 MBitConnection to the device upper partAttention: The socket (3) for the connection cable between the deviceback part and the device upper part must be clean in order to guaranteea good contact.568A 568BTX + green/white orange/whiteTX - green orangeRX + orange/white green/whiteRX - orange greenRelay outputFor activation of devices like turnstiles etc.. The relay contact is of type NO (maker contact). Please observe the max. permitted switching voltages and currents (see technical data).Depending on the connected instalation (e.g. turnstile) an additional free-wheeling diode may be necessary, which is used to limit the switch-on current. Please read the documentation of the connected installation.Optocoupler inputInput for status acquisition. For using the input a supply voltage must be applied. This voltage can be taken from the terminal‘s supply or from an external power source. Please observe the max. permitted input voltages and currents (see technical data).GAT Access 6100RX +TX -TX +GNDNO 1C 1IN1 -IN1 +RX -VIN +TCP/IPPower supply unite.g. GAT Power Supply SP014/1VOut+GNDABMains powerMotor controlFeedback controlMe.g. Turnstile1  Safety instructions-  This device must be installed by qualified personnel only.-  The applicable safety and accident prevention regulations must be observed.-  Safety devices must not be removed.-  Please observe the technical data of the device specified on the data sheet.-  The device must be disconnected from the power supply prior to installation, assembly or dismantling.