GS Instech GRS-TRIR-SPR Digital TRI User Manual ATT E

GS Instruments Co., Ltd. Digital TRI ATT E

user manual

FCC ID : U88-GRS-TRIR-SPR   HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517    FAX:+82 31 639 8525    www.hct.co.kr Report No. : HCTR1010FR02                                                                                                        1/1      ATTACHMENT E.   - USER MANUAL -
 Sprint User Manual Digital TRI-Band Indoor Repeater   1/22       3G Indoor Repeater  GRS-TRIR-SPR User Manual          AUGUST , 2010 Version 0.1
 Sprint User Manual Digital TRI-Band Indoor Repeater   2/22 - INDEX - 1. SUMMARY................................................................................... 3 2. SYSTEM CONFIGURATION ......................................................... 4 2.1 GRS-TRIR-SPR Service Organization.........................................................4 2.2 System Design and Operation....................................................................5 3. SPECIFICATIONS ..................................................................... 14 3.1 System Specifications(Applicable to both Uplink & Downlink)..오류! 책갈피가 정의되어 있지 않습니다. 3.2 Electrical and Environmental Specifications............................................14 3.3 Functions .................................................................................................16 4. SET UP...................................................................................... 18 4.1 System Set up..........................................................................................18
 Sprint User Manual Digital TRI-Band Indoor Repeater   3/22 1. SUMMARY  GRS-TRIR-SPR is an Digital RF repeater, which iDEN 800/900 and US PCS Band Service. This system has 90dB gain in the iDEN 800/900 band and PCS band respectively with 25dBm and 24dBm maximum power each  GRS-TRIR-SPR receives RF signal from BTS and transmits it to the blanked and shadowed area, thus providing and improving voice and image data services. GRS-TRIR-SPR’s goal is to support BTS’s functions proportionately.  GRS-TRIR-SPR communicates with BTS wirelessly, thus saving additional costs for its maintenance.  GRS-TRIR-SPR consists of RF/IF part Module, PA Module, Wave Module, Digital Filter module, and I/O & Control module divisions, which are supplied with Alarm LED, thus providing quick and easy maintenance and troubleshooting of the repeater.  This manual describes in general structure of GRS-TRIR-SPR, its application, maintenance and troubleshooting, installation and operation etc.  This equipment is indoor use and all the communication wirings are limited to inside of the building. CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN IN CORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS    Abbreviation PCS : Personal Communication System RF: Radio Frequency BTS: Base Transceiver Station IF: Intermediate Frequency I/O : Input/Output
 Sprint User Manual Digital TRI-Band Indoor Repeater   4/22 2. System Configuration 2.1 GRS-TRIR-SPR Service Organization GRS-TRIR-SPR decreases blanked and shadowed areas and extend cell coverage by re-transmitting signal. The signal is received from BTS via Antenna directly, thus excluding additional expenses for signal transmission (like cabling). Service organization of TRI Band(iDEN 800,900 and CDMA) In-building RF repeater is shown at the picture below. Donor Antenna is directed to BTS  and being divided at Service Antennas are installed in the building and parking place. Pass Loss should be taken into consideration while dividing and cabling.   <Pic.1> US PCS and iDEN 800/900 Service Organization
 Sprint User Manual Digital TRI-Band Indoor Repeater   5/22 2.2 System Design and Operation 2.2.1 System Design    <Pic.2> GRS-TRIR-SPR Repeater
 Sprint User Manual Digital TRI-Band Indoor Repeater   6/22    <Pic.3> Internal Design
 Sprint User Manual Digital TRI-Band Indoor Repeater   7/22  <Pic.4> Outside Port Design  NO  DESCRIPTION ① SERVER ANT PORT ② iDEN DONOR ANT PORT ③ PCS DONOR ANT PORT ④ AC POWER PORT ⑤ DC 12V PORT ⑥ CLI MONITOR PORT ⑦ ETHERNET PORT  ①② ③ ④ ⑤ ⑥  ⑦
 Sprint User Manual Digital TRI-Band Indoor Repeater   8/22 2.2.2 Downlink Path Downlink and Uplink Gain Budgets have similar structure. In case of Downlink Path, RF signal is received from Donor Antenna, and through FWD division, then the signal is transferred to IF division, where desirable Band is selected by Digital Filter. Selected Band is transferred to RF division again, and through FWD HPA, after that the signal is transmitted to User through Server Antenna. CDMA is used two attenuators for AGC compensation. AGC attenuation range of CDMA is 40dB. AGC attenuation range of iDEN 800/900 is 30dB.
 Sprint User Manual Digital TRI-Band Indoor Repeater   9/22  <Pic.5> Downlink Block Diagram
 Sprint User Manual Digital TRI-Band Indoor Repeater   10/22 2.2.3 Uplink Path Uplink Path is similar in structure to Downlink Path. In case of Uplink Path, RF signal is received from Server Antenna, and through RVS division, then the signal is transferred to IF division, where desirable Band is selected by Digital Filter. Selected Band is transferred to RF division again, and through RVS HPA, after that the signal is transmitted to BTS through Donor Antenna. CDMA is used two attenuators for AGC compensation. AGC attenuation range of CDMA is 40dB. AGC attenuation range of iDEN 800/900 is 30dB.
 Sprint User Manual Digital TRI-Band Indoor Repeater   11/22  <Pic.6> Uplink Block Diagram
 Sprint User Manual Digital TRI-Band Indoor Repeater   12/22 2.2.4 Frequency Selection <IDEN 800/900 BAND>  GRS-TRIR-SPR IDEN800 BAND has 18MHz, 7MHz Paths in IF division, so any of these bandwidths can be chosen for providing service. Also, by adding Channel Select Function, it enables users to select band offset sophisticatedly. iDEN 800/900 Band can changed bandwidth to 4MHz at 200kHz step of right band edge.    Max bandwidth Min Bandwidth Step 18M  4M iDEN 800 7M  4M iDEN 900  5M  4M 200kHz
 Sprint User Manual Digital TRI-Band Indoor Repeater   13/22 <US PCS BAND> 1930AB CDEF G1945 1950 1965  1970  1975  1990  1995 < Forward Band Structure >f (MHz) 1930AB CDEF G1945 1950 1965  1970  1975  1990  1995 < Forward Band Structure >f (MHz) 1850 AB CDEF G1865  1870 1885  1890  1895  1910  1915  f (MHz) < Reverse Band Structure >1850 AB CDEF G1865  1870 1885  1890  1895  1910  1915  f (MHz) < Reverse Band Structure >  <Pic.7> 1900MHz PCS Band Structure GRS-TRIR-SPR CDMA BAND has 5MHz, 10MHz, 15MHz, 20MHz Paths in IF division, so any of these bandwidths can be chosen for providing service. ITEM  BANDWIDTH  NOTE 5MHz 10MHz 15MHz 20MHz 5MHz + 5MHz 5MHz + 5MHz + 5MHz 10MHz + 5MHz Band Select 15MHz + 5MHz Any of these bandwidths from A to G can be chosen  Also, by adding Channel Select Function, it enables users to select bands sophisticatedly. Each band has 1.25 MHz Bandwidth and if users select all the 15 bands, GRS-TRIR-SPR can serve 18.75MHz bandwidth to users.
 Sprint User Manual Digital TRI-Band Indoor Repeater   14/22  3. SPECIFICATIONS 3.1 System Specifications(Applicable to both Uplink & Downlink)
 Sprint User Manual Digital TRI-Band Indoor Repeater   15/22    3.2 Electrical and Environmental Specifications ITEM  SPECIFICATION  REMARK Power & Consumption  120 VAC 60Hz    Connector Type  N-type female   Size  393 X 540 X 225   Weight  max 65 lbs   Reliability, MTBF  100,000 hours   Enclosure NEMA4   Operating Temperature  -10℃ ~ +50℃  Rel. Humidity  0% ~ 90%   Industry Standards  TIA-97, TIA-98, IS-98D, IS-2000   Regulatory Approvals  FCC, Part24 CDN-IC   Safety Approvals  UL1950 or Equiv
 Sprint User Manual Digital TRI-Band Indoor Repeater   16/22 3.3 Functions ITEM  FUNCTIONS Gain Control • Adjustable DL and UL Gain range 50~90dB(PCS) • Adjustable DL and UL Gain range 60~90dB(iDEN800/900) • Display default Gain and current Gain function AGC (Auto Gain Control) • It always operates in Downlink AGC ON status • To maintain same Downlink output power despite flexible input signal strength • To add or subtract Attenuation level referring to AGC Power Limit level.• Used with the Automatic Setup (Auto Gain Setting) ALC (Auto Level Control) • To limit output power as far as default range • Used for DAS configuration and when oscillation/isolation is a concern • Automatic Gain decrement when output power of repeater is higher than default level • Automatic Gain recovery when output power of repeater is reduced • Shutdown when output power is higher than default level in Minimum Gain • Automatic Recovery Algorithm conversion after Shutdown status AGS (Auto Gain Setting) • Operate when User control (Only system initialize) • Decrease attenuator value for 3dB from minimum gain • In case of attenuator value is from 0dB to 3dB when AGS ended - AGC on (DL) - Gain balance on - PAM on - Shutdown on • In case of attenuator value is over 3dB when AGS ended - AGC off (ALC on) - Gain balance on - PAM on - Shutdown on Gain Balance  • Downlink ATT is applied to Uplink during AGC state
 Sprint User Manual Digital TRI-Band Indoor Repeater   17/22 • Setting and maintenance of output level • Additional attenuation to ALC Level Band Select  • To select either 5MHz/10MHz/15MHz/20MHz (PCS) • To select either 18MHz/7MHz (IDEN 800) Power Monitoring Function  • Monitoring repeater’s output level DL Input control  • Monitoring Donor ANT input power of DL Automatic Recovery  • When repeater is shutdown, it periodically recovers output power of repeater then monitors alarming Security  • Support HTTPS for Web Browser security • User authentication through User ID and Password Temperature Monitoring • Monitoring temperature of repeater • Maximum and minimum set up is possible • Shutdown in over temperature • Automatic recovery after temperature becomes normal (Hysteresis 10degree) VSWR Monitoring  • Monitoring VSWR of Donor ANT Port (Every one and half minute) • Reporting VSWR Alarm  and Shutdown when the rate is  3.5:1 IP address report via E-mail • When in PPP reconnection, E-mail which includes HTML to connect to newly assigned IP Address, reports to operator. DHCP Client  • Automatic IP assignment DHCP Server  • Server function for automatic IP assignment Web GUI  • Remote and local user browser support through Web Browser SNMP Agent  • NMS report via SNMPv2 Trap LED Display • LED displays power and operation status on front side of repeater system • Input and Output signal levels are verified by LED bars
 Sprint User Manual Digital TRI-Band Indoor Repeater   18/22  4. SET UP  4.1 System Set up 4.1.1 Constitution (Based on 1 set) PARAMETER  ITEM  QUANTITY Major Accessory  GRS-TIRI-SPR  1 EA Additional Components Main power input cable Fixable screw Mountable brackets 1 EA 1 SET 1 EA User Manual  Manual  1 EA  4.1.2 Notice 1) System Power check: Major electricity is AC110V, therefore please input electricity after power verification. 2) Input condition optimization: DL input condition is -60 ~ -30dBm. User should verify input condition of Donor ANT. 3)  Isolation check between DONOR/SERVER ANT: Isolation condition of this equipment is 97dBc (Gain+7dB). User should check its condition before installation.   <Pic.8> MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug)
 Sprint User Manual Digital TRI-Band Indoor Repeater   19/22  CAUTION DOUBLE POLE/NEUTRAL FUSING 4.1.3 System Set up 1) This equipment is basically wall mountable installation. 2) Once aforementioned process is done, open for service get ready. 3) For grounding, there is a grounding terminal in main power supply side and the grounding terminal on a site and unit should be connected same. 4) System installation work is basically performed more than two people and should be careful for unexpected accident. 5) The socket-outlet shall be installed near the equipment and shall be easily accessible. 6)  Round terminals located on the side of a 0.75 mm2 (18 AWG) or more wires Using    permanently connected to earth.   <Pic.9> Case Mounts - Step 1
 Sprint User Manual Digital TRI-Band Indoor Repeater   20/22   <Pic.10> Case Mounts - Step 2   4.1.4 Open for Service 1) Check points before open a. Verification of system installation status - Electricity, In/out antenna, coaxial cable connection, and equipment mounts status. b. Verification of system accessories - User should check whole necessary accessories.    c. Check receipt signal level - User should check whether receipt environmental condition is in accordance with system specification, so that system operation will be optimized. 2) Check points after open a. Check by external LED
 Sprint User Manual Digital TRI-Band Indoor Repeater   21/22 ① RUN: Green light ON (Off: Green light off) ② ALARM: Green light in normal status, Red light in alarming ③ SHUT DOWN: Green light in normal status, Red light in Shutdown status ④ Number of LED bar on front side of repeater will show input power signal level Less than -86dBm: LED 1 bar -85dBm ~ -70dBm: LED 2 bar -69dBm ~ -54dBm: LED 3 bar -53dBm ~ -41dBm: LED 4 bar More than -40dBm: LED 5 bar  ⑤ Number of LED bar on front side of repeater will show output power signal level Less than +9dBm: LED 1 bar +10dBm ~ +14dBm: LED 2 bar +15dBm ~ +19dBm: LED 3 bar +20dBm ~ +24dBm: LED 4 bar More than +25dBm: LED 5 bar   <Pic.11> Front LED   b. Verification of operation status - User should verify following status with Output monitoring terminal, which is provided by Spectrum Analyzer - Output power generation status, system spurious emission characteristics.
 Sprint User Manual Digital TRI-Band Indoor Repeater   22/22 c. Verification of signal quality and strength in service area - User should verify signal strength and quality of in-service coverage area by using cell phone or other measuring device. d. Verification of upper-level NMS operation status
   MPE Information ⓒ SAMSUNG Electronics Co., Ltd.    Warning: Exposure to Radio Frequency Radiation The radiated output power of this device is far below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna should not be less than 30cm during normal operation. The gain of the antenna is 12 dBi.  The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Navigation menu