GIGA TMS UE600 UHF RFID Reader User Manual

GIGA-TMS INC. UHF RFID Reader Users Manual

Users Manual

                           UE600   User Guide  April 16, 2015 TM951326 - 01
   Any part of the contents of this document, without the express written GIGA-TMS permission, shall not in any documents, electronic, mechanical form of remakes or spread. File contents are subject to change without notice.   Revisions Revision  Date  Description 01  April 16, 2015  preliminary draft   Copyright© 2015 GIGA-TMS INC. Printed in Taiwan
Has been tested in accordance to essential protection requirements of the R&TTE Directive 1999/5/EC on the approximation of the laws of the Member States relating to Radio Spectrum Matters and found the test results indeed meet the limitation of the relevant test standard(s) listed below: EMC  Radio Spectrum  Safety EN 301 489 - 1: V1.9.2 (2011) EN 302 208 - 2: V1.4.1 : 2011 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 EN 301 489 - 3: V1.6.1 (2013) EN 302 208 - 1: V1.4.1 : 2011 Test standard: FCC rules Part 15 subpart C 15.247 (2013 - 10) Test Result: No deviations from the technical specification(s) were ascertained in the course of the tests performed. Test standard: FCC rules Part 15 subpart B Test Result: Radiated Emission. FCC Part 15. 109 / 15.107 Class B. Test passed.
Warning Federal Communication Commission (FCC) Interference Statement  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help.  FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices).  FCC Radiation Exposure Statement  This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.  This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Contents  Chapter 1:Introduction...........................................................................1 Chapter 2:About UE600 .........................................................................2 Specification........................................................................................................ 2 LED Indication ..................................................................................................... 3 Chapter 3:How to Use UE600 ................................................................4 Before Installing .................................................................................................. 4 Start to Use UE600 .............................................................................................. 4 Chapter 4:Troubleshooting ...................................................................5 Contact us..................................................................................................6
                                                                       UE600 User Guide               1  © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw Chapter 1:Introduction Introduce The UE600 is a desktop Ultra High Frequency RFID Reader compliant to ISO18000-6C EPC Gen 2 protocol with an operating range of 840 to 960 MHz. And UE600 also easy to use USB HID to connect PC and have auto sensor which can auto read  、write Tag.  The software UE600 Tag Issuer is supplied with the reader for Tag reading and writing.    Before using the UE600 Reader. We recommend that you should already read this user guide.  Fitting UE600 include antenna. The appearance as shown below                      UE600    Top view                                                UE600 USB Interface         60cm USB cable                                           table Please download software or user guide from following link: http://ftp.gigatms.com.tw/disks/disk5472/
                                                                        UE600 User Guide                            2 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw  Chapter 2:About UE600 Specification   USA  Europe UE600  UE600-00  UE600-30 Standard RFID spec  ISO 18000-6C, EPC Class1 Gen2 Frequency Range 902~928 MHz  865~868 MHz RF power  Max 16dBm Interface  USB HID Power Require  Standby : 110mA@5VDC Working : 300mA@5VDC,   Min power require : 500mA@ 5VDC RF Reading Range Max 20 cm (depending on Tag) Dimension  L: 120mm / W: 86mm / H: 79mm Physical Characteristics Weight  150g ( not Include USB cable ) Environment parameter Temperature  Operating : -10°C ~ 60°C Storage : -15°C ~ 65°C Humidity  Operating : 10% ~ 90% (no coagulation) Storage : Max 90% (no coagulation) Regulatory approvals CE R&TTE EN 302 208-1/-2 EN 301 489-1/-3 EN 60950-1 FCC ID PART 15B/C   Authentication ESD Conduct : 6kv , Air : 8kv
                                                                        UE600 User Guide                            3 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw  LED Indication    Status / Color Power / Red Read / Green Write / Yellow Buzzer / Beep Power ON      ON ON ON a beep Standby  ON OFF OFF OFF Read Success ON ON OFF a beep Read Fail  ON ON OFF 3  beeps Write Success ON OFF ON a beep Write Fail  ON OFF ON 3  beeps
                                                                        UE600 User Guide                            4 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw  Chapter 3:How to Use UE600 Before Installing  Before Install UE600. Please make sure the following items are ready.   A computer (Window XP / Vista / 7 or higher version systems) which already installed UHF Tag Manager.   A UE600 reader with USB cable.   UHF Tags (ISO18000 Class 1 Gen 2).   Start to Use UE600   Connecting UE600 on USB port of your PC.   Executing the software UHF Tag Manager to connect UE600.   Please refer to UE600 Software User Guide. There are instructions about how to read/write tags.     NOTE     The performance might be better or worse according to different tags and working environments.   UE600 can only read one tag at a time. Therefore, please keep other tags about 40cm away to reduce the interference.   Do not put tags to or near metal objects or liquid surface as possible.   Make sure there are not any same frequency devices or large power equipment in the same area.
                                                                        UE600 User Guide                            5 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw  Chapter 4:Troubleshooting 1.    Cannot connect to UE600 with UHF Tag Manager?   Please check the Power light of UE600 is lighting.   Please check USB cable is connecting well to PC.  2  Cannot read UHF Tags?   Please check the software UHF Tag Manager can find out UE600 and connect to it.   Please check the tag is a ‘UHF’ tag and is functional.   While you put a UHF tag on the top of UE600 and execute read command (or Auto) , the ‘Read’ light shall light up once.
                                                                        UE600 User Guide                            6 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw  Contact us  Address: 8F, NO.31, Lane 169, Kang-Ning Street, His-Chih Dist, New Taipei City, Taiwan  Tel: 886-2-26954214  Fax: 886-2--26954213  Websites: www.gigatms.com.tw  Email: Sales inquiry email - promag@gigatms.com.tw After sales service - support@gigatms.com.tw
                           TA500   User Guide  April 16, 2015 TM951328 - 01
   Any part of the contents of this document, without the express written GIGA-TMS permission, shall not in any documents, electronic, mechanical form of remakes or spread. File contents are subject to change without notice.   Revisions Revision  Date  Description 01  April 16, 2015  preliminary draft   Copyright© 2015 GIGA-TMS INC. Printed in Taiwan
Has been tested in accordance to essential protection requirements of the R&TTE Directive 1999/5/EC on the approximation of the laws of the Member States relating to Radio Spectrum Matters and found the test results indeed meet the limitation of the relevant test standard(s) listed below: EMC  Radio Spectrum  Safety EN 301 489 - 1: V1.9.2 (2011) EN 302 208 - 2: V1.4.1 : 2011 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 EN 301 489 - 3: V1.6.1 (2013) EN 302 208 - 1: V1.4.1 : 2011 Test standard: FCC rules Part 15 subpart C 15.247 (2013 - 10) Test Result: No deviations from the technical specification(s) were ascertained in the course of the tests performed. Test standard: FCC rules Part 15 subpart B Test Result: Radiated Emission. FCC Part 15. 109 / 15.107 Class B. Test passed.
Warning Federal Communication Commission (FCC) Interference Statement  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help.  FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices).  FCC Radiation Exposure Statement  This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.  This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Contents  Chapter 1:Introduction...........................................................................1 Chapter 2:About TA500 .........................................................................2 Specification........................................................................................................ 2 LED Indication ..................................................................................................... 3 Chapter 3:How to Use TA500 ................................................................4 Before Installing .................................................................................................. 4 Start to Use TA500 .............................................................................................. 4 Chapter 4:Troubleshooting ...................................................................5 Contact us..................................................................................................6
                                                                          TA500 ser Guide               1  © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw Chapter 1:Introduction Introduce The TA500 is a desktop Ultra High Frequency RFID Reader compliant to ISO18000-6C EPC Gen 2 protocol with an operating range of 840 to 960 MHz. As a smart UHF reader, TA500 also supports EPC Encoding and Decoding feature compatible with EPC Tag Data Standard (TDS) of GS1. And TA500 also easy to use USB HID to connect PC and have auto sensor which can auto read Tag.  The software TA500 Tag Issuer is supplied with the reader for Tag reading and analysis.    Before using the TA500 Reader. We recommend that you should already read this user guide.  Fitting TA500 include antenna. The appearance as shown below                      TA500 Top view                                                TA500 USB Interface          60cm USB cable                              table Please download software or user guide from following link: http://ftp.gigatms.com.tw/disks/disk5473/
                                                                        TA500 User Guide                            2 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw  Chapter 2:About TA500 Specification   USA  Europe TA500  TA500-00  TA500-30 Standard RFID spec  ISO 18000-6C, EPC Class1 Gen2 Frequency Range 902~928 MHz  865~868 MHz RF power  Max 16dBm Interface  USB HID Power Require  Standby : 110mA@5VDC Working : 300mA@5VDC,   Min power require : 500mA@ 5VDC RF Reading Range Max 20 cm (depending on Tag) Dimension  L: 120mm / W: 86mm / H: 79mm Physical Characteristics Weight  150g ( not Include USB cable ) Environment parameter Temperature  Operating : -10°C ~ 60°C Storage : -15°C ~ 65°C Humidity  Operating : 10% ~ 90% (no coagulation) Storage : Max 90% (no coagulation) Regulatory approvals CE R&TTE EN 302 208-1/-2 EN 301 489-1/-3 EN 60950-1 FCC ID PART 15B/C   Authentication ESD Conduct : 6kv , Air : 8kv
                                                                        TA500 User Guide                            3 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw  LED Indication    Status / Color  Power / Red Read / Green Buzzer / Beep Power ON      ON ON a beep Standby  ON OFF OFF Read Success  ON ON a beep Read Fail  ON ON 3 beeps
                                                                        TA500 User Guide                            4 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw  Chapter 3:How to Use TA500 Before Installing  Before Install TA500. Please make sure the following items are ready.   A computer (Window XP / Vista / 7 or higher version systems) which already installed UHF Tag Manager.   A TA500 reader with USB cable.   UHF Tags (ISO18000 Class 1 Gen 2).   Start to Use TA500   Connecting TA500 on USB port of your PC.   Executing the software UHF Tag Manager to connect TA500.   Please refer to TA500 Software User Guide. There are instructions about how to read tags.     NOTE     The performance might be better or worse according to different tags and working environments.   TA500 can only read one tag at a time. Therefore, please keep other tags about 40cm away to reduce the interference.   Do not put tags to or near metal objects or liquid surface as possible.   Make sure there are not any same frequency devices or large power equipment in the same area.
                                                                        TA500 User Guide                            5 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw  Chapter 4:Troubleshooting 1.    Cannot connect to TA500 with UHF Tag Manager?   Please check the Power light of TA500 is lighting.   Please check USB cable is connecting well to PC.  2  Cannot read UHF Tags?   Please check the software UHF Tag Manager can find out TA500 and connect to it.   Please check the tag is a ‘UHF’ tag and is functional.   While you put a UHF tag on the top of TA500 and execute read command (or Auto) , the ‘Read’ light shall light up once.
                                                                        TA500 User Guide                            6 © 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw   Contact us  Address: 8F, NO.31, Lane 169, Kang-Ning Street, His-Chih Dist, New Taipei City, Taiwan  Tel: 886-2-26954214  Fax: 886-2--26954213  Websites: www.gigatms.com.tw  Email: Sales inquiry email - promag@gigatms.com.tw After sales service - support@gigatms.com.tw

Navigation menu