GE MDS INET900 MDS iNet 900 User Manual MDS iNET Installation Guide Draft 3 12 17 01

GE MDS LLC MDS iNet 900 MDS iNET Installation Guide Draft 3 12 17 01

Contents

installation guide

 Installation Guide Review Draft 3—12/17/01 Wireless IP/Ethernet Transceiver MDS 05-2873A01, REV. D3DECEMBER 2001 MDS   i NET   900 ™
 MDS 05-2873A01, Rev. D3 Installation Guide 1 Review Draft 3—12/17/01 CONTENTS ABOUT THIS MANUAL............................................................4 PRODUCT DESCRIPTION......................................................4 INSTALLATION PLANNING.....................................................5 INSTALLATION ........................................................................6 Step 1—Mount the Transceiver....................................................6Step 2—Install the Antenna .........................................................7Step 3—Measure & Install Primary Power...................................7Step 4—Review the Radio’s Configuration ..................................8Step 5—Connect the Data Equipment.........................................9Step 6—Check for Normal Operation ........................................10Performance Optimization..........................................................10 TROUBLESHOOTING...........................................................11 iNET SPECIFICATIONS ........................................................13 IN CASE OF DIFFICULTY... ..................................................14 INSTALLATION REFERENCE CHART ............. (Center Insert) Copyright Notice This publication is protected by U.S. copyright law. Copyright 2001, Micro-wave Data Systems, Inc. All rights reserved. Serviceability of this Manual While every reasonable effort has been made to ensure the accuracy of this manual, product improvements may result in minor differences between the manual and the product shipped to you. If you have additional questions or need an exact specification for a product, please contact our Customer Service Team using the information at the back of this guide. Microwave Data Systems Incorporated reserves its right to correct any errors and omissions. Updated information may also be available on our Web site at www.microwavedata.com.
 2Installation Guide  MDS 05-2873A01, Rev. D3  Review Draft 3—12/17/01 Operational Safety Notices The radio equipment described in this guide emits radio frequency energy. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. Do not allow people to come closer than two meters (6 feet) to the antenna when the transmitter is operating. This manual is intended to guide a professional installer in installing, oper-ating and performing basic system maintenance on the described equipment.  FM/UL/CSA Notice  MDS  i Net 900 When Approved This product is available for use in Class I, Division 2, Groups A, B, C & D Hazardous Locations. Such locations are defined in Article 500 of the National Fire Protection Association (NFPA) publication NFPA 70, otherwise known as the National Elec-trical Code. The transceiver has been recognized for use in these hazardous locations by three independent agencies —Underwriters Laboratories (UL), Factory Mutual Research Corporation (FMRC) and the Canadian Standards Association (CSA). The UL certi-fication for the transceiver is as a Recognized Component for use in these hazardous locations, in accordance with UL Standard 1604. The FMRC Approval is in accor-dance with FMRC Standard 3611. The CSA Certification is in accordance with CSA STD C22.2 No. 213-M1987.  FM/UL/CSA Conditions of Approval MDS  i Net 900 When Approved The transceiver is not acceptable as a stand-alone unit for use in the hazardous loca-tions described above. It must either be mounted within another piece of equipment which is certified for hazardous locations, or installed within guidelines, or conditions of approval, as set forth by the approving agencies. These conditions of approval are as follows:1. The transceiver must be mounted within a separate enclosure which is suitable for the intended application.2. The antenna feedline, DC power cable and interface cable must be routed through conduit in accordance with the National Electrical Code.3. Installation, operation and maintenance of the transceiver should be in accor-dance with the transceiver's installation manual, and the National Electrical Code.4. Tampering or replacement with non-factory components may adversely affect the safe use of the transceiver in hazardous locations, and may void the approval.RF Exposure
 MDS 05-2873A01, Rev. D3 Installation Guide 3 Review Draft 3—12/17/01 Do not disconnect equipment unless power has been switched off or the area is know to be non-hazardous.Refer to Articles 500 through 502 of the National Electrical Code (NFPA 70) for further information on hazardous locations and approved Division 2 wiring methods.    1 Z? FCC Notice, U.S.A. MDS  i Net 900 When Approved The MDS iNet 900 transceivers comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful inter-ference, and (2) this device must accept any interference received, including interfer-ence that may cause undesired operation.This device is specifically designed to be used under Section 15.247 of the FCC Rules and Regulations. Any unauthorized modification or changes to this device without the express approval of Microwave Data Systems may void the user’s authority to operate this device.Furthermore, this device is indented to be used only when installed in accordance with the instructions outlined in this manual. Failure to comply with these instructions may also void the user’s authority to operate this device. FCC Information This equipment has been tested and found to comply with the limits for a Class A dig-ital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre-quency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 1. This seem like this note should be a DANGER classification if there is a potential for an explosion. Please verify.EXPLOSIONHAZARD!
 4Installation Guide  MDS 05-2873A01, Rev. D3  Review Draft 3—12/17/01 ABOUT THIS MANUAL This guide presents installation and initial operating instructions for the MDS  iNET  900™ transceiver. Following installation, we suggest keeping this guide near the equipment for future reference.The scope of this manual is limited to the safe and effective installation of the unit in typical office or non-hazardous industrial settings. Users who require optimization of the equipment’s capabilities and oper-ating range should read the  MDS iNET 900 Network Administrator’s Manual , P/N 05-xxxxA01. This manual provides more in-depth infor-mation on antenna selection and optimization, and extensive coverage on user-controllable parameters and diagnostic tools.Many of the essential installation information is contained on the  Installation Reference Chart  found at the center of this manual. PRODUCT DESCRIPTION The MDS  iNET  900 transceiver (shown on the cover) is a data radio transceiver designed for to support wireless data networks.The MDS  iNET  900 transceiver is designed to provide network man-agers with a easy-to-install wireless local area network (LAN) services with plug-and-play hardware. The unit can be reconfigured for any one of three standard operating arrangements; some require the use of electronic keys (alphanumeric code) purchased from MDS. The model descriptions reflect their operating mode capabilities. The core data interface services are 1. Ethernet, 2. Serial, and 3. Serial and Ethernet. (See Table 1 on page 5 for a summary of core interface services.)Three model configurations are available; they are:1. Ethernet Bridge—Supports Ethernet traffic only2. Serial gateway—Supports serial traffic only (Encrypted over IP protocol)3. Access Point/Dual Gateway—Supports Ethernet and serial data simultaneously
 MDS 05-2873A01, Rev. D3 Installation Guide 5 Review Draft 3—12/17/01 The MDS  iNET  900 transceivers serve as either an “Access Point” or “Remote Gateway”. An Access Point is a wireless hub that provides connectivity into a wired Ethernet LAN/WAN. From a radio perspec-tive, an Access Point also serves as the radio network’s “master sta-tion” providing synchronization signaling for associated  iNET  900 Remote Gateway radios. INSTALLATION PLANNING This section provides tips for selecting an appropriate site, choosing an antenna system, and reducing the chance of harmful interference. General Requirements There are three main requirements for installing the radio—adequate and stable primary power, a good antenna system, and the correct interface between the transceiver and the data device. The center  Installation Reference Chart  shows a typical Remote Gateway instal-lation.  Table 1.  i NET 900 Models and Data Interface Services Model Oper. Mode LAN Data(IP/Ethernet) COM1Data COM1MGT Sys. AccessCOM2Data Ethernet Bridge 1 Remote Gateway Yes No Yes NoSerial 1 Remote Gateway No Yes Yes YesDual Gateway 2 Remote Gateway & Access PointYes Yes Yes Yes NOTES  1. Firmware key required to convert to alternate operating modes: Remote Serial/LAN Gateway, Ethernet Bridge, or Access Point Oper-ation.2. Default: Remote Serial/LAN Gateway. Able to be converted to Access Point without firmware key
 6Installation Guide  MDS 05-2873A01, Rev. D3  Review Draft 3—12/17/01 Access Point stations are similar, but typically they use an omni-direc-tional antenna and a Local-Area Network (LAN) or a Wide-Area Net-work connected to the LAN port. The Access Point iNET radio provides a connection to the wired network for devices attached to the Remote Gateways.Antennas are a vital link in the system; they must be chosen and installed correctly. The  MDS iNET 900 Network Manager’s Manual  provides details on choosing a site and making antenna selections INSTALLATION A typical transceiver product shipment consists of an iNET 900 trans-ceiver and a manual. Check the contents against the packing list attached to the outside of the shipping box. Below are the basic steps for installing a  i NET 900 transceiver. Should further information be required, see “IN CASE OF DIFFICULTY...” on page 14 of this manual for information on contacting the factory. You will also find support information at the Microwave Data System Web site at www.MicrowaveData.com on the Internet. NOTE: It is recommended that the Access Point station be installed  first.  In this way, it will be possible to quickly check the operation of each associated Remote Gateway unit as it is placed on the air. MDS iNET  900 transceivers are shipped from the factory set to the “Remote Gateway” mode unless they are marked differently. Step 1—Mount the Transceiver Mount the transceiver to a stable surface. (Fasteners/anchors/screws are not supplied unless specified when the order.) Four threaded holes are located on the bottom of the radio that are suitable for connecting mounting hardware. Use 6-32 x 1/4 inch screws to attach mounting hardware to the bottom of the radio.
 MDS 05-2873A01, Rev. D3 Installation Guide 7 Review Draft 3—12/17/01 Screws used to hold the mounting brackets to the radio should be 5⁄16 inch (8 mm) long or shorter to prevent damage to the radio’s internal PC board. If these screws are replaced for any reason, the new screws must not exceed this length. The radio’s case is made of a durable cast-aluminum, however, the use of the wrong sized screws can damage the screw sockets on the cover. Step 2—Install the Antenna The antenna and  i NET 900 unit should be mounted with the antenna a minimum of six inches (15 cm) from other equipment, especially metallic objects. NOTE: Radio frequency energy generated by the  i NET 900 can interfere with the operation of nearby low-level RTU circuits and change the reported values of the data being monitored. For this reason, the antenna should be mounted at least 10 feet (>3 meters) from the RTU, sensors and other components of the system.General information on the selection and installation of antenna sys-tems is provided in the  MDS iNET 900 Network Manager’s Manual .  Step 3—Measure & Install Primary Power  The primary power at the transceiver’s power connector must be within 10.5–30 Vdc and be capable of continuously furnishing up to 500 mA. The optimum voltage is 13.8 Vdc. Be sure to observe proper polarity as shown in Figure 1. A power connector is provided with each radio suitable for use with pigtail leads. Invisible place holder Figure 1. Primary Power (DC) Polarity The radio is designed to be used only in nega-tive-ground systems. Make sure the polarity of the power source is correct. Reverse polarity will dam-age the  iNET  900’s circuitry and will result in per-manent damage to the unit.CAUTIONPOSSIBLEEQUIPMENTDAMAGECAUTIONPOSSIBLEEQUIPMENTDAMAGE
 8Installation Guide  MDS 05-2873A01, Rev. D3  Review Draft 3—12/17/01 The power supply used with the transceiver should be equipped with overload protection (NEC Class 2 rating), to protect against a short cir-cuit between its output terminals and the transceiver power connector. Step 4—Review the Radio’s Configuration There are two essential settings for  i NET 900 transceivers that should be known before placing the radio into service. They are: Radio Operating Mode —Access Point or Remote Gateway Network Name— Unique name of the radio network that is used to generate the hopping pattern. NOTE: Transceivers are normally shipped from the factory config-ured as a Remote Gateway. Unit IP Address —Must be a unique number to allow for IP access through the Ethernet Port. Transmitter Power Output Level —Default is 1 Watt. Adjust as necessary for compliance with FCC guidelines. NOTE: A unique IP address is important if the radio’s LAN (Ethernet) port will be used for IP-based data communica-tions or for unit configuration. NOTE: The  COM1  port’s only function is to provide access to the iNET 900’s management system. COM2 is not functional at this time.The following is a summary of the installation procedure. For more detailed instructions on using the menu-based COM1 and the HTTP/Bowser interfaces, please read the  MDS iNET 900 Network Administrator’s Handbook . Procedure a. Connect a personal computer’s serial communications port (COM1 or COM2) to the  COM1  Port connector on the radio transceiver. (See the I nstallation Reference Chart  for location. Data defaults: 19,200 kbs/8N1.)b. Launch a terminal emulator program, such as HyperTerminal, on the computer.c. Depress the  ENTER  key. The radio will respond with the start-up screen of a text-based Management System.
 MDS 05-2873A01, Rev. D3 Installation Guide 9 Review Draft 3—12/17/01 d. A login with password will be required to make any changes to the radio. (Default =  admin )e. Select the desired options to review existing settings and to initiate necessary changes such as the IP address and other network parameters. Changes are saved in the unit’s flash memory.f. Repeat the above steps for each transceiver in the network. Basic  i NET Unit Parameter Defaults The table on the center  Installation Reference Chart  provides a sum-mary of basic operating parameter’s range of and default values. All of these are available through the  i NET’s Management System acces-sible through a terminal emulator connected to the  COM1  port. Step 5—Connect the Data Equipment Connect Ethernet/IP-compatible equipment data equipment to the transceiver’s LAN port. The port supports only 10BaseT.Use only the required pins for the application—do not connect any-thing to unused pins. Use a straight-through Ethernet cable to connect to a hub or a crossover cable to connect directly to an Ethernet station or RTU. See the  Installation Reference Chart  in the middle of this guide for pinout information. Remote Gateway —If the radio network seems to be operating prop-erly based on observation of the unit’s LEDs, connect the user data equipment to the LAN port. Use the IP  PING  command to verify the communications link integrity with the Access Point unit. Access Point —Connect the WAN/LAN to the LAN port of the radio. LED Indicators A table of LED functions can be found on the center  Installation Ref-erence Chart .
 10 Installation Guide  MDS 05-2873A01, Rev. D3  Review Draft 3—12/17/01 Step 6—Check for Normal Operation a. Observe the transceiver LED status panel (See the  Installation Reference Chart ) for the proper indications. In a normally operating system, the following LED indications will be seen within 30 seconds of start-up:• PWR— Lit continuously• LINK —Blinks intermittently at Remote Gateways and contin-uously on Access Point stations.• LAN —On indicates it connected to a good Ethernet cable. Blinks (flickers) with data activity.b. Check the received signal strength indicator (RSSI) for an adequate signal level from the radio network’s Access Point station. (RSSI available through the iNET Management Sys-tem) It may be necessary to reposition the gateway radio’s antenna for better reception/signal strength, or if a directional antenna is used, rotate it until the signal is optimized.See the  Installation Reference Chart  for details on the LED functions and chart of Management System menus. If all checks out OK, you are done with the installation. Congratula-tions! Performance Optimization After the basic operation of the radio has been checked, you may wish to optimize its performance using some of the suggestions given here. The effectiveness of these techniques will vary with the design of your system and the format of the data being sent.Complete instructions on using the unit’s configuration options refer-enced within this section are can be found in the MDS iNET 900 Net-work Manager’s Manual.
MDS 05-2873A01, Rev. D3 Installation Guide 11Review Draft 3—12/17/01TROUBLESHOOTINGIt is best to begin troubleshooting at the Access Point station, as the rest of the system depends on the Access Point for polling instructions and synchronization data. If the Access Point station has problems, the operation of the entire network will be affected.All radios in the network must meet these basic requirements:•Adequate and stable primary power•An efficient and properly aligned antenna system• Secure connections (RF, data & power)• Proper programming of the radio’s operating parameters, especially Mode selection (Access Point/Remote), Network Name, and IP Network Address• The correct interface between the radio and the connected data equipment (proper cable wiring, data format and timing).Table 2 on page 12 provides suggestions for resolving system difficul-ties that may be experienced in the radio system. If problems persist, contact the factory for further assistance. Refer to the inside back cover of this guide for contact information.
12 Installation Guide  MDS 05-2873A01, Rev. D3 Review Draft 3—12/17/01Table 2. Troubleshooting TechniquesDifficulty Recommended System ChecksThe PWR LED does not turn on. a. Check for the proper supply voltage at the power connector.b. Cycle the power and wait for the unit to reboot. (≈ 30 seconds)Interference is suspected. a. Verify that the system has a unique network name. A nearby systems (Access Point station) with the same network name will cause interference.b. If omnidirectional antennas are used on, consider changing to directional antennas. This will often limit interference to and from other stations.c. The installation of a filter in the antenna line may be necessary. Consult the factory for further assistance.The LINK LED does not turn on.  a. Check for secure interface connections at the radio and the connected device.b. Check the antenna, feedline and connectors. Reflected power should be less than 10% of the forward power reading (SWR ≈2:1 or lower).c. No synchronization with Access Point, or poor overall performance. Check RSSI level.Cannot pass IP data to WAN. a. Use the PING command to test communication with iNET units in the local radio system.b. If successful with local PING, attempt to PING an IP unit attached to an iNET radio.c. If successful with the LAN PINGs, try connecting to a known unit in the WAN.
MDS 05-2873A01, Rev. D3 Installation Guide 13Review Draft 3—12/17/01INET SPECIFICATIONSGENERALTemperature Range: –30°C to +70°C (–22° F to 158° F)Humidity: 95% at +40°C (104° F); non-condensingPrimary Power: 10.5–30 Vdc(13.8 Vdc Nominal)External Power Supply Options: 48 Vdc; 110–120/210–220 VacSupply Current (typical): (@1 Watt RF Output)Transmit: 500 mA @ 13.8 VdcSize (Excluding mtg. hardware): 1.5" x 6" x 4" (H x W x D)3.8 x 15.2 x 10.2 cmWeight: 0.9 kg / 2 lbCase: Cast AluminumShock and Vibration: Meets MIL STD 202F, 810E, 202DRADIO CHARACTERISTICSGENERAL:Frequency Range: 902–928 MHz ISM BandMode: Freq. Hopping Spread-Spectrum (FHSS)TRANSMITTER:Power Output(at antenna connector): 0.1 to 1.0 watt (+20 dBm to +30 dBm) Increments of1.0 dB, set by userDuty Cycle: ContinuousOutput Impedance: 50 OhmsRECEIVER:Type: Double conversion superheterodyneSensitivity: –92 dBm @ 512 kbps < 1x10-6 BER–100 dBm @ 256 kbps < 1x10-6 BERTime Required to Synchronizewith Access Point Radio: Less than 13 seconds (typical)
14 Installation Guide  MDS 05-2873A01, Rev. D3 Review Draft 3—12/17/01IN CASE OF DIFFICULTY...MDS products are designed for long life and trouble-free opera-tion. However, this equipment, as with all electronic equipment may have an occasional component failure. The following infor-mation will assist you in the event that servicing becomes neces-sary.TECHNICAL ASSISTANCETechnical assistance for MDS products is available from our Cus-tomer Support Team during business hours (8:00 A.M.–5:30 P.M. Eastern Time). When calling, please give the complete model number of the radio, along with a description of the trouble symptom(s) that you are experiencing. In many cases, problems can be resolved over the telephone, without the need for returning the unit to the factory.Telephone 1+ 585-242-8510 for product assistance or visit the tech-nical support area of the Microwave Data Systems’ Web site at www.MicrowaveData.com.FACTORY SERVICEIf return of the equipment is necessary, please contact the MDS Cus-tomer Support Team. You will be issued a Returned Material Autho-rization (RMA) number. The RMA number will help expedite the repair so that the equipment can be repaired and returned to you as quickly as possible. Please be sure to include the RMA number on the outside of the shipping box, and on any correspondence relating to the repair. No equipment will be accepted for repair without an RMA number.A statement should accompany the radio describing, in detail, the trouble symptom(s), and a description of any associated equipment normally connected to the radio. It is also important to include the name and telephone number of a person in your organization who can be contacted if additional information is required.
MDS 05-2873A01, Rev. D3 Installation Guide 15Review Draft 3—12/17/01The radio must be properly packed for return to the factory. The orig-inal shipping container and packaging materials should be used when-ever possible. All factory returns should be addressed to:When repairs have been completed, the equipment will be returned to you by the same shipping method used to send it to the factory. Please specify if you wish to make different shipping arrangements. Microwave Data Systems Inc.Customer Service Department(RMA No. XXXX)175 Science ParkwayRochester, NY 14620 USA
 175 Science Parkway, Rochester, New York 14620General Business: +1 (716) 242-9600FAX: +1 (716) 242-9620Web: www.microwavedata.com