Mount the backplate using countersunk headed screws adjacent to the opening edge of the door and at a convenient height (recommended height is 5' (1.5m) to top of unit).If fixing hole ’A’ is used then the breakout must be removed and the screw must not protrude.Feed the required cables through the backplate:·The cable from the controller.·A cable from a External Reader (Optional).·General Purpose Input / Output cable (Optional)If wall tamper function is to be used then breakout ‘B’ must be removed and an appropriate wall screw fitted through the hole to actuate the tamper lever.21Mount the BackplateReader ConnectionsThe S884 is a and keypad. The reader can be set to use Wiegand or The S884 reader will read smartMAX encoded MIFARE cards and card serial numbers from most ISO 14443A smart cards which have a 4-byte UID (User Identification).  The reader may be configured to read other card types by presenting a programming card to the reader during start up.contactless smart-card reader, with Graphic LCD 20mA current loop communications.The securing screws ‘C’ are integral to the backplate and are unscrewed via the small holes in the enclosure so that the screw heads  locate in the counterbored holes on the inside of the enclosure.You should find that the backplate has holes for connection to most standard electrical backboxes.CABInstallation and User Instructions for S884 Readers0VRX+RX-TX+TX-12VController0VTX+TX-RX+RX-+VReaderTB120mA current loop0VGreenData 0RedData 112VController0VGRN0+VUse Belden 9537 CableWiegandRED1ReaderTB1Connect shield at controller end only.Connect shield at controller end only.Twisted pairs (use Belden 9503 Cables)Note: Use LK2 to select the communications mode (See Step 3).Set LK2 (COMMS) across the center and W pin for Wiegand communications, or across the center and C pin for 20mA current loop communications. Set LK3 (USER Keypad audio feedback) to 1 for sound on, or 0 for sound off. Set LK4 (EXT RDR) across the center and W pin for Wiegand communications, or across the center and M pin for Magstripe Reader communications.3Reader Links
4External Reader Connections (Optional)0V0/CK1/DA+VReaderTB1Magstripe0V0/CK1/DA+VReaderTB1WiegandWiegand ReaderMagstripe ReaderIN 1IN 2CSPKRReaderTB2I/O Connections5General Purpose Inputs & Outputs (Optional)COMNCNOSPKRPresent the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid succession;there is no need, for example, to wait for "UNLOCKED" to disappear before presenting another.If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the O key, entering your card number, then pressing the P key.                               A Setup menu can be displayed by pressing the O and P keys simultaneously while power is applied. You can use the menu to change the contrast and language used for the LCD (default English). Use the four function keys to navigate around the menu.9600-0537. Installation and User Instructions for S884 Readers, Issue 1.0 11th March 2010.   G4S Technology, 2010. FCC Notice: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Any unauthorized modification to this device may void the authority of the user to operate it. All trademarks acknowledged.©LED Status IndicatorGREEN – The lock is released and you may open the door.RED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case, present it again).YELLOW – Enter your PIN. If you make a mistake, the message INVALID PIN is momentarily displayed, followed by ENTER PIN, to prompt you to try again.SpecificationsInput voltage: 9-14Vdc. Input current:  200mA @ nom. 12Vdc.Operating temperature: 14 to 131°F (-10 to 55°C)Operating humidity: 15 to 90%, non-condensing.Maximum read range: 4" (100mm).Approvals: EN50133, EN302291, EN3014896Using the ReaderNote: Use LK4 to select the External Reader type (See Step 3).The reader is connected to the controller using the 20mA current loop scheme shown in section 2 and, in addition, the external reader is connected as shown below.0VClockData12V0V0s1s12V

Navigation menu