Installation and User Instructions for S853 ReadersYou should find that thebackplate has holes forconnection to moststandard electricalbackboxes.With the backplate off (see above), mountthe backplate adjacent to the opening edgeof the door and at a convenient height. Feedthe required cables through the backplate:The cable from the controller.The cable from the heater, if used (mustbe a separate cable).A cable from a Remote Interface Module(RIM), if used. A RIM can reduce cablelengths to door furniture.!!!2The optional heater kit maintains the reader atthe correct temperature when mounted outside.With the backplate off, remove the backing paperfrom the two elements, then stick them to theinner sides of the reader. The heaters must beconnected to a 24V AC supply (min 25VA).When mounting outside, the two-part gasket kitmust be fitted:a) Remove the backplate from the reader byreleasing the two securing screws.b) Remove the cutouts and backing paperfrom the two gaskets, then stick them to thebackplate as shown.Outer gasketInnergasketBackplatesecuring screwsBackplate1Fit the Weatherproofing KitMount the BackplateEnsure no jumpers are fitted across LK2 (TEST) and LK3 (NODE TERM) and LK4 (HGU TERM). If ajumper is provided, park it across one pin only. LK1 (USER FB) - set to 1 for sound on and 0 for sound off.3Reader LinksThe S853 is a combined contact and contactless smart-card reader, with LCD and keypad, which usesp . The S853 isable to read Philips MIFARE and Philips MIFARE DESfiresmart cards.For either type of card, the S853 supports the use ofunencoded cards (where only the unique card serialnumber is read), or cards encoded with a card number.Several encoding formats are supported.The reader can simultaneously support two different cardtypes/formats (e.g. non-encoded MIFARE and smartMAX-encoded MIFARE DESfire, or non-encoded MIFARE andsmartMAX-encoded MIFARE). The reader is automaticallyconfigured to accept the first two contactless and the firstcontact card types/formats presented.20mAcurrent loop seudo-random communications®®
SpecificationsInput voltage: 9-14Vdc.Input current (excl. heater): 195mA @ nom. 12Vdc.Operating temperature: -4 to 158 F (-20 to 70 C)without heater.Operating humidity: 15 to 90%, non-condensing.Max. read range (MIFARE DESfire): 1.2" (30mm).Approvals: EN50133, R&TTE, IP656.°°0VConnect shield at controllerend only (attach to case).RX+RX-TX+TX-12V ReaderTwisted pairs (useBelden 9503 cable)Controllerconnections(20mA currentloop)The I/O terminal is forconnection to a RIM (seethe RIM Instructions).On completion, re-securethe reader to the backplate.0VTX+Do not useTX-I/0RX+RX-+V4Reader Connections9600-0348. Installation and User Instructions for S853 Readers,Issue 1.0 5th August 2004. Group 4 Technology, 2004.All trademarks acknowledged. Philips andMIFARE are registered trademarks of Philips Electronics N.V.FCC Notice: This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions: (1) This devicemay not cause harmful interference, and (2) this device must acceptany interference received, including interference that may causeundesired operation.Any unauthorized modification to this device may void the authority ofthe user to operate it.©For a contactless card, present the card face-on to the reader until you hear "bleep". For a contact card,insert the card (chip upwards and facing you) into the slot at the bottom of the reader until you hear a"bleep". Cards can be presented in rapid succession; there is no need, for example, to wait forUNLOCKED" to efore presenting another." disappear bIf the reader has been enabled for user-code mode at the controller, you can gain access by pressingthe # key, entering your card number, then pressing the * key.About the Reader Messages}READYUNLOCKEDACCESS DENIED & LOCKEDENTER PINCARD PIN AND #–– The lock is released and you may open the door.– You do not have access rights to gain entry, or the readerdid not read your card properly (in this case, present it again).– Enter your PIN. If you make a mistake, the message INCORRECT PIN ismomentarily displayed, followed by ENTER PIN, to prompt you to try again.– Enter the DESfire card PIN, then press # if the PIN is less than 8 digits.The reader is waiting for a valid card to be presented.(Flashing or steady) – These auxiliary indicators can be configured to operate inconjunction with conditional commands.6Using the ReaderThe reader supports the first two contactless and the first contact card types/formats presented afterpower-up. For example, encoded MIFARE and encoded MIFARE DESfire (in this example, unencodedcards would not be recognized). The reader enters this configuration mode whenever power is re-applied.A reader Setup menu can be displayed by pressing the * and # keys simultaneously while power isapplied. You can use the menu to change the contrast and language used for the LCD (default English),and view/clear the three card types/formats programmed. At the prompts, press * for No and # for Yes.5Reader Configuration

Navigation menu