G4S Technology S844 S844 Inductive Reader User Manual

G4S Technology Limited S844 Inductive Reader

User Manual

Installation and User Instructions for S844 ReadersYou should find that the backplate has holes for connection to most standard electrical backboxes.With the backplate off (see above), mount the backplate adjacent to the opening edge of the door and at a convenient height. Feed the required cables through the backplate:!The cable from the controller.!The cable from the heater, if used (must be a separate cable).!A cable from a Remote Interface Module (RIM), if used. A RIM can reduce cable lengths to door furniture.2The optional heater kit maintains the reader at the correct temperature when mounted outside. With the backplate off, remove the backing paper from the two elements, then stick them to the inner sides of the reader. The heaters must be connected to a 24V AC supply (min 25VA).When mounting outside, the two-part gasket kit must be fitted:a) Remove the backplate from the reader by releasing the two securing screws.b) Remove the cutouts and backing paper from the two gaskets, then stick them to the backplate as shown.Outer gasketInner gasketBackplate securing screwsBackplate1Fit the Weatherproofing Kit Mount the BackplateSet LK1 (USER FB) to 1 for sound on, or 0 for sound off. If a jumper is provided for LK2 (TEST), park it across one pin only. Set LK3 (COMMS) across the center and WGD pin for Wiegand communications, or across the center and C/L pin for 20mA current loop communications.3Reader LinksThe S844 is a keypad. The reader can be set to use Wiegand or pThe S844 is able to read Personal Identity Verification (PIV II) type A and B, Philips MIFARE and Philips MIFARE DESfire smart cards. For Philips MIFARE and Philips MIFARE DESfire cards, the S844 supports  the use of unencoded cards (where only the unique card serial number is read), or cards encoded with a card number. Several encoding formats are supported.  The reader can simultaneously support two different card types/formats (e.g. non-encoded MIFARE and smartMAX-encoded MIFARE DESfire, or non-encoded MIFARE and smartMAX-encoded MIFARE). The reader is automatically configured to accept the first two card types/formats presented after power is applied.Note: For PIV II compliance, Wiegand communications should be used.contactless smart-card reader, with LCD and 20mA current loop  seudo-random communications.
0VConnect shieldat controller end only.   RX+RX-TX+TX-12VReaderController20mA current loopThe I/O terminal is for connection to a RIM (see the RIM Instructions).Slide the ferrite sleeve onto cable before wiring terminal block.  Ferrite to be placed 50mm (2") up cable and held in place with cable ties.0VTX+TX-I/0RX+RX-+VTwisted pairs (useBelden 9503 cable)     Connect shieldat controller end only.   GroundData 0GreenData 112VReaderControllerWiegand0V0GRN1+VUse Belden9537 cable   Present the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid succession;there is no need, for example, to wait for "UNLOCKED" to disappear before presenting another.If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the # key, entering your card number, then pressing the * key.                               A Setup menu can be displayed by pressing the * and # keys simultaneously while power is applied. You can use the menu to change the contrast and language used for the LCD (default English). At the prompts, press * for No and # for Yes. 9600-0452. Installation and User Instructions for S844 Readers, Issue 2.0.1 8th December 2009.   G4S Technology, 2009. FCC Notice: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Any unauthorized modification to this device may void the authority of the user to operate it. All trademarks acknowledged.©About the Reader Messages}READY – UNLOCKED – The lock is released and you may open the door.ACCESS DENIED & LOCKED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case, present it again).ENTER PIN – Enter your PIN. If you make a mistake, the message INCORRECT PIN is momentarily displayed, followed by ENTER PIN, to prompt you to try again.CARD PIN AND # – Enter the DESfire card PIN, then press # if the PIN is less than 8 digits.The reader is waiting for a valid card to be presented.(Flashing or steady) – These auxiliary indicators can be configured to operate in conjunction with conditional commands.SpecificationsInput voltage: 10.2-14Vdc. Input current (excl. heater): 180mA @ nom. 12Vdc.Operating temperature: -4 to 158 F (-20 to 70 C) without heater. Operating humidity: 15 to 90%, non-condensing.Maximum read range: 3/4" (20mm).Approvals: EN50133, R&TTE, IP656.° °5Using the Reader4Reader ConnectionsNote: The FERRITE must be fitted!Note: Use LK3 to select the communications mode (see step 3).

Navigation menu