Furuno USA 9ZWWR2100 Dual Polarimetric X-band Weather Radar User Manual II

Furuno USA Inc Dual Polarimetric X-band Weather Radar II

Contents

User Manual II

SSE-14-0023_2       INSTALLATION MANUAL   Compact Dual Polarimetric X-band Doppler Weather Radar    MODEL   WR-2100                        www.furuno.com Date of Printing Feb. 01, 2014
SSE-14-0023_2                                                   FURUNO ELECTRIC CO.,LTD.  9-52 Ashihara-cho, Nishinomiya, 662-8580, Japan     Printed in Japan  ( TAHA )      WR-2100      ・FURUNO Authorized Distributor/Dealer A  :  FEB. 2014  All rights reserved
SSE-14-0023_2 i IMPORTANT NOTICES  General •  This manual has been authored with simplified grammar, to meet the needs of international users. •    The operator of this equipment must read and follow the descriptions in this manual. Wrong operation or maintenance can cancel the warranty or cause injury. •    Do not copy any part of this manual without written permission from FURUNO. •    If this manual is lost or worn, contact your dealer about replacement. •    The contents of this manual and equipment specifications can change without notice. •    The example screens (or illustrations) shown in this manual can be different from the screens you see on your display. The screens you see depend on your system configuration and equipment settings. •    Save this manual for future reference. •    Any modification of the equipment (including software) by persons not authorized by FURUNO will cancel the warranty. •    All brand and product names are trademarks, registered trademarks or service marks of their respective holders.   How to discard this product Discard this product according to local regulations for the disposal of industrial waste. For disposal in the USA, see the homepage of the Electronics Industries Alliance (http://www.eiae.org/) for the correct method of disposal.
SSE-14-0023_2 ii            SAFETY INSTRUCTIONS  The user and installer must read the appropriate safety instructions before attempting to install or operate the equipment.  Indicates a hazardous situation which, if not avoided, will result in death or serious injury.  Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.  Indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury.   WARNING Radio Frequency Radiation Hazard The radar antenna sends the electromagnetic radio frequency (RF) energy. This energy can be dangerous to you, especially on your eyes. Do not look at the radiator or near the antenna when the antenna is rotating. The distances at which RF radiation levels of 100 W/m 2 , 50 W/m 2   and 10 W/m 2  exist are shown in the table. DO NOT go near more than 5.9m (Safety standard is 10 W/m 2 ). Distance from Antenna 1.1m 2.8m 5.9m Power flux density 100 W/m 2   50 W/m 2   10 W/m 2         WARNING Do not open the radome. Electrical shock can occur. Only qualified personnel should work inside the equipment.  Wear a hard hat and safety belt when mounting the antenna unit. Serious injury or death can result if someone falls from the radar antenna. Do not use any other power except 100 to 240 VAC. Connection of an incorrect power supply can cause fire or damage the equipment. Turn off the power immediately if water leaks into the equipment or smoke or fire is coming from the equipment. Failure to turn off the equipment can cause fire or electrical shock. Do not operate the equipment with wet hands. Electrical shock can occur. Do not disassemble or modify the equipment. Fire or electrical shock can occur. CAUTION WARNING DANGER
SSE-14-0023_2 iii   WARNING LABEL Warning labels are attached to the equipment. Do not remove any label. If a label is missing or damaged, contact us for the replacement.     Use only the specified power cable. Fire or damage to the equipment can result if a different cable is used. Use the power supply grounded certainly.   Electrical shock or defect of operation can occur. When a thunderbolt is expected, do not approach a system or do not touch a hand. There is a possibility of receiving an electric shock. A worker's safety is guaranteed although the measures which protect apparatus from indirect lightning stroke serge are taken against this machine.   It is not a thing. Moreover, if a direct stroke is impressed, it may break down. Attach securely protective earth to the unit.   The protective earth (grounding) is required to the AC power supply to prevent electrical shock.  CAUTION Do not put liquid-filled containers on the top of the equipment. Fire or electrical shock can occur if a liquid spills into the equipment. Establish space in the surroundings of apparatus as much as possible.   It becomes a cause of performance degradation and failure. Do not put any strong impact to LCD because of glass. Serious injury may cause by broken glass. Antenna Unit (radome) Name:    Radiation Warning Label Type :     03-142-3201-0 number :   100-266-890-10
SSE-14-0023_2    Compact Dual Polarimetric X-band Doppler Weather Radar                               WR-2100 Installation manual   CONTENTS IMPORTANT NOTICES .......................................... i SAFETY INSTRUCTIONS ......................................ii System Configuration ............................................ v 1. System Summary ....................................... 1-1 2. Equipment Configuration ................................ 2-1 2.1. Equipment List ..................................... 2-1 2.2. Cable List ............................................. 2-1 3. Overall appearance ........................................ 3-1 4. Prior confirmation ............................................ 4-1 4.1. Confirmation items ............................... 4-1 4.2. Construction materials ......................... 4-1 4.3. Others ................................................... 4-1 4.4. Power equipment   ............................... 4-1 4.5. Construction tools ................................ 4-2 4.6. Measurement ....................................... 4-2 4.7. LAN equipment .................................... 4-2 5. Precautionary item .......................................... 5-1 6. Construction .................................................... 6-1 6.1. Mount kit ............................................... 6-1 6.2. Antenna Unit ........................................ 6-2 6.3. Signal Processing Unit ......................... 6-7 6.4. Display Unit ........................................ 6-10 6.5. AC Power strip   ................................. 6-10 7. Operation Test ................................................ 7-1 7.1. Before cover ......................................... 7-1 7.2. After cover ............................................ 7-2 8. Install TeamViewer ......................................... 8-1  9. PC operation .............................................. 9-1 9.1. File .................................................. 9-1 9.2. Disp ................................................. 9-1 9.3. Setting ............................................. 9-1 9.3.1. Setting .................................. 9-1 9.3.2. Service ................................. 9-5 9.3.3. Factory setting ...................... 9-9 9.3.4. Management list ................. 9-15 9.4. Radar Operation ........................... 9-19 9.5. Help ............................................... 9-19 9.6. Emergency Stop ........................... 9-19 9.7. Adjustment of Azimuth .................. 9-20 9.8. Total operation test ....................... 9-21 10. Menu Tree ............................................. 10-1 11. Specification .......................................... 11-1 11.1. Antenna Unit   ............................. 11-1 11.2. Signal Processing Unit   .............. 11-2 11.3. Display Unit   ............................... 11-3 12. APPENDIX .......................................... 12-1 12.1. Outline drawing   ......................... 12-1 12.2. System diagram .......................... 12-5           www.furuno.com All brand and product names are trademarks, registered trademarks of service marks of their respective holders.
SSE-14-0023_2 v System Configuration  The observation system consists of an Antenna Unit (Radome), a Signal Processing Unit   (storage box) , and a Display Unit (indoor unit) are shown below.   (1) Antenna Unit (radome)   An antenna is stored in the radome, is turned, and radiates the radio waves.   The radiated waves are backscattered by precipitation particles on the propagation path, return to the antenna, and are processed by RF converter to transfer the signals to the Signal Processing Unit   (2) Signal Processing Unit (storage box)   Signal Processing Unit is stored in the storage box, and processes received signals digitally.   The digitally-processed signals are transferred to the display unit via 1000Base-T (LAN) .   (3) Display Unit (indoor unit)     The data is displayed graphically and stored with a general-purpose personal computer  (PC) .                                    WR-2100 ATU WR-2100 SPU Display Unit (indoor)  AC100-240  UPS USB cable  AC100-240  AC cable  Display Unit  (Option) USB cable  Existing LAN / Inter net / Modem LAN cable  LAN adapter  AC100-240  AC100-240 External HDD  AC cable  LAN cable  Coaxial cable AC / Dsub cable  AC100-240  LAN ケcable FURUNO * Examples of using UPS
SSE-14-0023_2 1-1 1. System Summary This system observes the development of rain clouds, outputs the strength of precipitation and the speed of rain clouds (Doppler speed) , and observes phenomena of rainfall.    Features :   1. Installation to building roof in Urban area. -  Antenna must install in the safety area of lightning rod.                 -  Nothing should be surrounded around the antenna area.
SSE-14-0023_2 1-2 2. High Resolution Rain Observation, Rain Cloud, Density and Speed Observation.   3. Solid-state Transmitter replaces an aging device such as a magnetron.
SSE-14-0023_2 2-1 2. Equipment Configuration 2.1. Equipment List PRODUCT NAME MODEL  Compact Dual Polarimetric X-band Doppler Weather Radar WR-2100    Items Units  Descriptions  Qty Antenna Unit WR-2100-ATU Size : Ф1086mm×H1024mm (include radome)   Weight : 70Kg Weight of radome only: Upper 17kg, Bottom 9kg 1 Signal Processing Unit WR-2100-SPU  Size : W725×D300×H750mm (include storage box)   Weight : 60kg 1 Display Unit WR-2100-DPU  General PC (ex. HP envy dv7)   1 Mounting Kit for Radome Type A  Size : 900mm×800mm×t 10mm, Weight : 15kg 1 Type B  Size : 950mm×920mm×t 10mm, Weight : 18kg  2.2. Cable List Antenna Unit (radome) <-> Signal Processing Unit (storage box) cable  Items Descriptions Length Qty Signal cable 25pin cable (Both Dsub-25pin)   5m  1 Com cable 9pin cable (Both Dsub-9pin)   5m  1 RF cable 3D-2W (Both SMA-P Connector)   5m  3 AC Power cable VCTF Power cable 3core 1.25sq 5m  1 Signal processing unit (storage box) <-> Display unit (storage box) cable LAN cable For outdoor 1000 Base-T Cat5e or better by measure 1 AC power cable VCTF Power cable 3core 1.25sq  by measure 1 Protective tube for cable Protective tube Flexible conduit Inner diameter : 28 mm radome --- storage box by measure 2 Protective tube Flexible conduit Inner diameter : 28 mm storage box --- indoor by measure 2 Earth wire To protection against electric shock by measure 1
SSE-14-0023_2 3-2 3. Overall appearance                         2)  Signal Processing Unit (storage box) . 1) Antenna Unit (radome)   Unit: mm Unit: mm
SSE-14-0023_2 3-3                         Specification List of draw (Refer to 12.1. Outline drawing) No Items Drawing Number 1  Antenna Unit (Radome)   52-037-200G-2 2  Signal Processing Unit (storage box)   52-037-202G-0 3 Mount plate of Radome 52-037-2301-1 52-037-2302-0  4)  Display Unit    (General Laptop PC)            Reference dimension :     418mm x 278mm x 37mm   Unit: mm 3)    Mount plate of Radome e.g. 52-037-2302-0
SSE-14-0023_2 4-1 4. Prior confirmation 4.1. Confirmation Items 1. The mount kit must be installed properly for Antenna Unit (radome). 2. Power cable (AC100V-240V) must be laid safely. 3. Power cable thickness should be selected depends on its length. 4. Frequency of AC power source must be 50Hz or 60Hz sin wave and single-phase current. 5. All engineers must wear the safety appliances such as a helmet, and safety shoes during an installation of antenna unit. It is very dangerous that Antenna might hit a head by turning. 6. DO NOT look the antenna closer while radar is in operation. This energy can extremely damage to the human body and especially to the eyes. Furthermore, DO NOT point the antenna to the people closer while transmitting. * The following table is shown the distance of Transmit radio wave to be 100W/m2, 50W/m2, 10W/m2. The value of Safe standard is 10W/ m2, do not go closer than 5.9m.  4.2. Construction materials (include equipments in “2. Equipment Configuration”) Items Descriptions Qty M10x35 Hexagon Bolt Material : SUS304 (Fix for up/down parts of radome)   12 M10 Spring Washers Material : SUS304 (Fix for up/down parts of radome)    12 M10 Flat Washers Material : SUS304 (Fix for up/down parts of radome)   12 M12x40 Hexagon Bolt    Material : SUS304 (Fix for radome and mount plate)  5 M12 Spring Washers Material : SUS304 (Fix for radome and mount plate)  5 M12 Flat washers    Material : SUS304 (Fix for radome and mount plate)  5 M16x40 Hexagon Bolt (*1) Material : SUS304 (Fixed for mount plate and a base)   12 M16 Nut Material : SUS304 (Fixed for mount plate and a base)   12 M16 Spring Washer Material : SUS304 (Fixed for mount plate and a base)   12 M16 Flat Washer Material : SUS304 (Fixed for mount plate and a base)   24 FV2-M4 Round Crimping Terminal For electric cables  6 Putty for pipe Non-hardening, Electric insulation qs Multi Plug Outlet Power strip (3-core) 4-Outlets minimum w/ surge protector  1 Heavy Duty Cable Tie (2 types) Nylon 6/6 w/ weather resistance 140mm, 300mm 100 M10 Anker Bolt Fixed for SPU  4 Earth wire 2sq green To protection against electric shock 1 *1: Length of Hexagon Bolt will depend on a thickness of a base.  4.3. Others Items Descriptions Qty Key of storage box No.200  2  4.4. Power equipment This equipment must need 1KVA x1 line of power, with ground outlet (3 pin type)
SSE-14-0023_2 4-2 4.5. Construction tools   Items Descriptions SMA Torque wrench 74Z-0-0-21 SMA connector conclusion Substitute : Caliber 5/16 inch or 8mm wrench Socket Wrench (4 types) M8 (13mm), M10 (17mm), M12 (19 mm)、M16 (24mm)   hexagon bolt (Substitute : Monkey wrench)   Hexagon Wrench   (3 types of Ball-point) M3 (2.5mm), M4 (3mm), M5 (4mm)   Bolt with Hexagon hole [+] Driver No.1   Dsub-9pin [+] Driver No.2 M3, M4, M5, Dsub-25pin, for Electric Filter [+] Driver No.2 (Long type) Length 30cm minimum fixed for PXI   [-] Driver M8 Multiuse Box Driver (2 types) 5mm, 5.5mm fixed for Dsub connector Flat Ratchet (3 types) M10 (17mm), M12 (19mm), M16 (24mm) Nipper   For wiring work Wire Strippers For wiring work Electrical workers knives   For wiring work Crimped Terminal tool 1.25sq Power cable (M4), GND wire (M8) for wiring work Tape Measures (5m minimum) Measure length of outdoor power cable and LAN cable Self-fusing Tape (Black)   Fit Tape insulation / protect (Length 10m)   Electrical Tape (Black)   Heat & Fire proof (L19m x W20mm x D0.18mm) Curing Tape   Multiuse Chemiseal  S-8400W Aluminum Tube 50G Silicone grease Temperature range -30 to +200 °C Safety belt For high place work  4.6. Measurement Items Descriptions Remarks Digital Multi Meter Voltage  AC : 85 to 240 V  DC : 1 to 50V Current  AC : 1 to 10 A  DC : 1mA to 1A  Resistor 0.1 to 10M ohm Tester   Lead Cables Angle Meter Measurement range : ≧ 45deg   Accuracy : within ±0.2deg Zero adjustment vertical angle of RADAR  4.7. LAN equipment 1) Use Cat5e (or better grade) of 1000Base-Tx LAN cable for transferring the data from display unit to output equipment. 2) Be prepared High speed broadband (approx.100Mbps) for using remote maintenance. *Low speed broadband may cause slow access on remote to support a system.
SSE-14-0023_2 5-1 5. Precautionary item 1) Use only the commercial power supply of single phase 100-240VAC. 2) DO NOT overhaul or remodel. 3) DO NOT work during the thunder is occurring. 4) DO NOT scratch, cut, forcedly bend, pull, twist, bundle, or damage the power cable. Also, not to put a heavy thing on top or interpose. 5) DO NOT touch inside equipment with a wet hand. 6) Connect the ground conductor for protecting equipment and electric shock prevention from lightning induction and ground leakage. 7) Cleaning instruction: Use dried soft cloth to wipe the surface. If it is difficult to remove stains, use the cloth soak with a neutral detergent to clean it. Please DO NOT use an alcohol or an organic solvent (e.g.: thinner) to clean it.  For optional equipment: Please refer to attached documents of UPS, Router, and other equipments separately.
SSE-14-0023_2 6-1 6. Construction All installation places will be considered for installing PC, cables, pipes, and mount kit during the environmental survey.  6.1. Mount kit <Case 1> The case of not able to make a hole on pedestal.           <Case 2> The way of using steel frames.                      Open more than 100mm of space. Adjust the hole (10 holes [   ] ) with the mount plate and the steel frames. Make holes to the steel frames with 20Φ for M16 hexagon bolt to join with the mount plate.
SSE-14-0023_2 6-2  <Case 3> The way to put the mount plate directly on to a wooden pedestal.                6.2. Antenna Unit (Radome)  1.Set up the base.         2.Set the bottom of radome to the base. (1)    Adjust the cable introduction of under radome to notch of the base.  (2)    To fit the bottom of radome with five salient into the base hole  (3)  To fix 5 pcs of M12x35 hexagon bolt (with M12 spring washer, M12 flat washer) to join the base and radome.   The mount plate (900mm×800mm×10mm) Make 10 holes [   ] to a wooden pedestal with  20Φ  for  M16  hexagon  bolt  to  join  with the mount plate. In this case, it may need to make 2 big holes for Protecting Tube to get through. Bottom of radome
SSE-14-0023_2 6-3 Under view:     3.In case to reinstall the antenna   (1)    Fit the pin of Rotary waveguide (2)    Fix the rotary pedestal by 6 pcs of M5x15 with hexagon bolt hole SEMS B. (3)    Fix the waveguide by 2 pcs of M4x15 with hexagon bolt hole SEMS B.   Hole of the mount plate & Salient of the bottom of radome Notch & Cable instruction of the mount plate M12x35 hexagon bolt M12 spring washer M12 flat washer Antenna M4x15 with hexagon bolt hole SEMS B Pin M5x15 with hexagon bolt hole SEMS B Waveguide Rotary waveguide Rotary pedestal
SSE-14-0023_2 6-4 4. Every location must have to measure a length in between ATU  SPU  DPU for  adjustment. And to lay the Protecting Tube.               5. Insert the outdoor cable into the cable waveguide (6 pcs). Protecting Tube 1 :   - AC Power cable (3cores) Protecting Tube 2 :   - Coaxial Cable (3 pcs) - Communication cable (both end Dsub-25pin connector)   - Signal cable   (both end Dsub-9pin connector)    Remove the connector cover of Dsub-25pin and 9pin while sending through the Protecting Tube to the other side.  Basically Coaxial cable is up to 5m. (15m maximum)    SPU DPU (Indoor) PT 2 PT 1 PT 4 PT 3 ATU Fix by fastening plate Dsub25pin connector  Dsub25pin connector  Connector cover
SSE-14-0023_2 6-5   6. Wire the RF Unit (1) Connect all cable with following the name of tag on cable and label on the unit. (2) Connect / Fix coaxial cable (3 pcs) with torque wrench (74Z-0-0-21). (3) Connect / Fix communication cable (both end Dsub-25pin connector) with L type Offset driver +1 (TD-61).    7.Wire the MTR Unit (1) Connect the Signal cable (both end Dsub-9pin connector) (2) Tighten 2 screws of connector fix by (+) driver  8.  Tighten all screws of Dsub connector by (+) driver or socket wrench. Torque wrench  L type Offset driver +1  RF Unit  Signal cable  Coaxial cable  Communication cable
SSE-14-0023_2 6-6  9.Wire the power filter  Caution: Make sure an electric current is not flow (1) Fix / Connect AC power cable (3pin) (2) Confirm the circuit diagram of power filter label before connecting. (3) Connect the LINE side to match with the line color of LOAD side and LINE side.  <Wire color> Type JIS IWR US  EU P/L  +  Black  Black  Black  Brown N  -  White White White or Gray Blue GND FG Green/ Yellow Red (Terminal Green) Green Green/ Yellow     10.Activation test - Turn “ON” the switch of Antenna rotary motor.   Antenna rotary motor switch “OFF” Antenna rotary motor switch “ON”  11.Cover the top of radome - Make sure the switch of antenna rotary motor is “ON” before put on the top part of radome - Fix the upper part of radome and the bottom part of radome by 10 pcs of M10x35 bolt.   Power filter  M10x35 M10 spring washers M10 flat washers
SSE-14-0023_2 6-7 6.3. Signal Processing Unit (Store into storage box)    1.Insert outdoor cable into cable waveguide (10 pcs)   Cables run between SPU and Display Unit Protecting Tube 4 : AC power cable (3pin)   Protecting Tube 3 : LAN cable Cables run between SPU and Antenna Unit (radome) Protecting Tube 2 : Coaxial cable (3 pcs)   Protecting Tube 1 : AC power cable (3pin)   Communication cable (both end Dsub-25pin connector)   Signal cable   (both end Dsub-9pin connector)     Remove the connector cover and run Dsub-25pin connector and Dsub-9pin connector through Protecting Tube. Reinstall the cover after passed through the Protecting Tube. ・Insert the GND wire through the GND/Cable ground.            2. Connect FG cable - Crimp the crimped terminal (M8) to the cable - Screw up the cable to the FG terminal. - This FG terminal should be connected with the building grounding electrode system.  *Taping it with coaxial cables Protecting Tube
SSE-14-0023_2 6-8  3. Connect the cable from Display Unit *Caution: Make sure an electric current is not flow (1) Connect the AC power cables (3pin) to the terminal base (TB1) (2) Connect SPU  Unit LAN cable to the connector F3-LINE (3) Connect LAN cable (for the Power switch) to the connector F2-LINE  4. Connect the cable of the Antenna Unit (radome) (1) Connect the AC power cables (3pin) to the terminal base (TB3) (2) Connect and fix the signal cable (Dsub-9pin connector) to each S-COM connector, and communication cable (Dsub-25pin connector) to RF-CONT SIG connector. (3) Fix with the torque wrench (74Z-0-0-21) after connecting 3 coaxial cables (TX IF, RX IF V, RX IF H) to SPU – UNIT connector.            5.Fix the wire -  Fix the cable tie with slacking the cable without making a tension to the connector of communication cable (Dsub-25pin connector), signal cable, and coaxial cables (3 pcs).   3. (2)(3) LAN cables 4. (3) Coaxial cable  4. (2) Signal cables 4. (1) AC power cables 3. (1) AC power cables
SSE-14-0023_2 6-9  6.Make the power plug (beside Display Unit) -  Make 3 pin earthed power plug that running through the SPU. -  Place an outlet  7. Activation test -  Turn on the power breaker. -  Follow the instruction to test it.               8. Cooler setting Setup temperature of cooler to 25 Celsius degrees .  (1) Press [Set] button to indicate a temperature of setting. (2) Press [Up], [Down] button to setup a temperature to 25 Celsius degree. (3) Press [Set] button to indicate a current temperature.  9. Measure the AC power - Measure the value of AC power that comes into SPU from the main outlet.   - Reference range:    -10% to +10% 10. Connect LAN cable to connect with display unit.    Control panel Display (Temperature will indicate when power up) Setup button Alarm lamp (RED) Lamp ON: Alarm occurs Lamp Blink: Forced heater ON Down button Up button Alarm lamp (GREEN) Lamp ON: Cooler ON Lamp OFF: Cooler OFF 0.5S Lamp Blink: Forced cooler ON 1.0S Lamp Blink: Heater ON Air inlet Terminal unit Air inlet Air fan and outlet 25
SSE-14-0023_2 6-10 6.4. Display Unit (General laptop PC)  6.5. AC Power strip Setup 4 or more outlet of AC power strip (3 core) beside display unit for display unit, HDD, and radar unit. UPS and Switching Hub / Router may be used(that depends on an order). Notice:  To  lay LAN cable between  PC and modem/router during installation when customer prepare an internet environment with modem/router for using remote control.                               1.Setup Display Unit (PC) (1) Connect LAN cable from SPU to PC (2) Connect AC power cable (3) Connect LAN cable from modem to USB LAN adaptor for PC ③  ①  ②  WR2100-RDP External HDD WR2100-SPU WR2100-ATU
SSE-14-0023_2 7-1 7. Operation Test Follow the step as below :   7.1. Before cover (Upper part of radome)           *It might cause a damage to the human body, especially to eyes if receiving the transmit radio wave directly in short distance.                                                                    (1)  Turn on the power of Display Unit (PC)     (2)  Stay away from radar farther than 5.9m   (8)  Cover radome   (4)  Start the observation from the menu of the display unit Complete   (3)  Place an outlet (main power) to supply the power to radar unit   (5)  Stop rotate radar and emission (STBY).   (6)  Adjust an angle of elevation to 0 by angle meter (refer the instruction of adjustment from separate sheet)
SSE-14-0023_2 7-2 7.2. After cover (Upper part of radome)                           (1) Be sure the power of radar unit and Display Unit (PC) are ON.    (2) Start the observation from the menu of the display unit  Complete    (3) Set to indicate the observation state, picture to the Display Unit, and to output the data periodically.
SSE-14-0023_2 8-1 8. Install TeamViewer (Remote control management tool) 1. Download the software of TeamViewer Host (For remote server) from the following web site: http : //www.teamviewer.com/ja/download/windows.aspx 2. Double click “TeamViewer_Host_Setup.exe” to install the software.                                   3. After installed software, please inform “Your ID” to the headquarter of Furuno who is in charge. 4. Use other PC to confirm remote access by TeamViewer.     (6)    “Your ID” will be issued automatically.   (* Remember this ID)   And then click [OK] (1) Double click the icon (2) Click [Next] (3) Select  “company / commercial use”, and then click [Next] (4)  Check on “License Agreement”, and then click [Next] (5)   Make password and computer name Password: rmsrms (enter this password) Computer name: Enter location’s name And then click [Exit] 123 456 789
SSE-14-0023_2 8-2 5. The following instruction is to setup security on TeamViewer Host if necessary. * Please confirm to a customer and Furuno Headquarter before setup.  (1)  Right click to the icon of TeamViewer in task bar. (2)  [TeamViewer options] will indicate  a Popup menu on  a  screen after clicked [Option] from dropdown list of TeamViewer.     (3)  Click [Security] on the right list of  [TeamViewer options] (4) Click [Configure] of [Black and whitelist] under a menu of [Rules  for connections to this computer].    (5) It could register an opponent ID on the list  to whether [Deny access for the following IDs and partners] or [Allow access only for the following IDs and partners] from Popup menu of [Black and whitelist].

Navigation menu