Fudakang NC100 Infrared Thermometer User Manual NC100 UserManual 171019

Fudakang Industrial Co., LTD Infrared Thermometer NC100 UserManual 171019

Users Manual

NC100 Bluetooth Non-Contact Infrared  ThermometerUser  ManualNC100
Dear NC100 Owner:Thank you for purchasing the NC100 Bluetooth Non-Contact Infrared Thermometer. Please read this instruction manual rst so you can use this thermometer safely and correctly. Please keep this instruction manual for future reference. This innovative medical device uses advanced infrared (IR) technology to measure temperature instantly and accurately on the forehead or object.IMPORTANT SAFETY INSTRUC-TIONS READ BEFORE USEThe following basic safety precautions should always be taken.1. Close supervision is necessary when the thermometer is used by, on, or near children, handicapped persons or invalids.2. Use the thermometer only for the intended use described in this manual.3. Do not use the thermometer if it is not working properly, or if it has suered any damage.KEEP THESE INSTRUCTIONS IN A SAFE PLACE03
Table of ContentBEFORE YOU BEGIN      Cautions and Warnings     Restrictions of Use       Intended Use        How does it work     Highlighted Features     Package Contents     Meter Overview     Display Screen     Display Mode     Select the Temperature Unit     Replacing the Battery     Setting the ThermometerDETAILED INFORMATION     About Normal Body Temperature and FeverPERFORM THE TEST    Using the Device        As a Body Measurement Thermometer         As an Object Measurement ThermometerMETER MEMORY     Recalling the MemoryMAINTENANCE     Care and CleaningSYSTEM TROUBLESHOOTING     Measurement Result     TroubleshootingSYMBOL INFORMATIONSPECIFICATIONSSTATEMENTS AND DECLARATIONSDISPOSALREFERENCE STANDARDSWARRANTY050505060606070708080910101111121212141515161617171819202123242504
BEFORE YOU BEGINCautions and Warnings˙As with any thermometer, proper technique is crucial to     obtaining accurate temperature readings. Please read this     manual thoroughly and carefully before using.˙Always operate the thermometer in an operating temperature     range 10°C to 40°C (50°F to 104°F), and relative humidity less     than 80%.˙Always store the thermometer in a cool and dry place -25°C to     55°C (-13°F to 131°F) and relative humidity less than 95%.˙Avoid direct sunlight.˙Avoid dropping the thermometer, if it happens and you think     the thermometer may be damaged, please contact customer     services immediately.˙Do not touch the lens.˙Do not disassemble the thermometer.˙Basic safety precautions should always be observed, especially     when the thermometer is used on or near children and disabled     persons.˙This thermometer is not intended to substitute for a consulta-    tion with your physician.˙This thermometer and the subject must remain in a stable     environment for at least 30 minutes before measuring the     temperature.˙When the measured temperature falls within the fever tempera-    ture range of ≥37.8°C (100°F) and <43°C (109.4°F), as indicated     by the red LCD display, please consult with your physician     immediately.This thermometer is clinically proven to produce accurate temperature measurements. However, please be advised that the accuracy cannot be ensured when the thermometer is not clean. Check that the probe is clean before taking a measurement.Restrictions of  Use05
Intended UseHow Does It WorkHighlighted FeaturesNC100 Bluetooth Non-Contact Infrared Thermometer is intended for the intermittent measurement and monitoring of human body temperature from forehead measurement at home. A control measurement using a conventional thermometer is recommended in the following cases:1. If the reading is surprisingly low,2. For new-born infants up to 100 days old,3. For children under three years of age who have a weakened     immune system or who react unusually in the presence or     absence of fever.The thermometer measures the infrared heat generated by the surface of the skin over the vessel and its surrounding tissue. The thermometer then converts it into a temperature value.˙Non-contact measurement that does not require probe cover,     thereby saving cost of replacement.˙Automatically power o if left idle for 60 seconds.˙Memory function allows you to recall previous forehead results      up to 32 previous results.˙Easy to read LCD with blue and red backlight in a dark environ-    ment.˙Color visible indication of alarm (red) and measurement in     progress (blue).˙Measurement within 5 cm.NOTE:The thermometer does not emit any infrared signal.06
Package ContentMeter OverviewThermometer SiliconeDust CoverUser Manual 1.5 V AAAAlkalinebatteries x 21243567Front view Back view1. Display Screen2. Setting Button3. Power Button4. Measure / Memory Button5. Battery Cover6. Light Indicator7. Sensor Probe07
Press setting button once to switch between.Display ModeDisplay Mode1. Low battery indicator2. Object temperature indicator3. Temperature reading4. Date5. Memory mode6. Body temperature indicator7. Temperature unit8. Time1. Body Mode    ˙This mode is used to measure the         forehead temperature.    ˙It also provides clock.2. Object Mode    ˙This mode is used to measure the        object temperature.    ˙It also provides clock.1234567808
This meter provides two measurement units used for indicating the body/object temperature, °C or °F, for your preferred selection.Select the Temperature UnitReplacing the BatteryThe thermometer comes with two 1.5 V AAA alkaline batteries. The meter will display "     " to alert you when the meter power is getting low. Please follow the steps below to replace new batteries immediately.NOTE:1. Although the thermometer works when "          " appears, we still     recommend that you change the batteries to obtain an accurate     result.2. Remove the batteries if planned to store for a long period of time.3. The batteries should be kept away out of child’s reach. If they are     swallowed, promptly see a doctor for help.Press Measure / Memory Button to toggle between °C or °F.Press Setting Button to exit.2.3.Press Power button to turn ON the meter.  Press Setting Button for 3 seconds to enter the screen. 1.LCD side facing upwards.Press the end link upwards and remove it.Remove old batteries and replace with two 1.5 V AAA alkaline batteries.  Follow the correct position of positive “+” and negative “-“ as indication.Insert and press the end link downwards into the main unit.1.2.3.4.09
You will need to set time for rst-time use or after replacing the batteries.Setting is all completed. Press Setting Button to exit the setting mode.1. Entering the setting mode     Start with the meter ON, press Setting      Button for 5 seconds to enter the setting      mode.2. To set the date and time    Press Measure / Memory Button to select     the correct year. Press Setting Button to     conrm and move to the next step.  The     same step for month/day/hour/minute     settings.Setting the Thermometer10
The temperature on the forehead and temple area diers from the internal temperature, which is taken orally or rectally. Vasoconstric-tion, an eect which constricts the blood vessels and cools the skin, can occur during the early stages of a fever. In this case, the temperature measured by the NC100 Bluetooth Non-Contact Infrared Thermometer may be unusually low. If the measurement therefore does not match the patient’s own perception or is unusually low, repeat the measurement every 15 minutes. As a reference, you can also measure the internal body temperature using a conventional oral or rectal thermometer.Body temperature can vary from one individual/ person to next. It also varies by location on the body and time of day. Below shows the statistical normal ranges from dierent sites. Please keep in mind that temperatures measured from dierent sites, even at the same time, should not be directly compared. Fever indicates that the body temperature is higher than normal. This symptom may be caused by infection, overdressing or immunization. Some people may not experience fever even when they are ill. These include, but are not limited to, infants younger than 3 months old, persons with compromised immune systems, persons taking antibiotics, steroids or antipyretics (aspirin, ibuprofen, acetaminophen), or persons with certain chronic illnesses. Please consult your physician when you feel ill even if you do not have fever.DETAILED INFORMATIONAbout Normal Body Temperature and FeverTable*   Body Site Normal Temperature Range*1. Body Temperature at WebMD;      website: http://rstaid.webmd.com/body-temperature      retrieved at 2010 Jan 7.Oral 0.6°C (1°F) or more above or below37°C (98.6°F)Rectal/ear 0.3°C to 0.6°C (0.5°F to 1°F) higherthan oral temperatureAxillary(armpit)0.3°C to 0.6°C (0.5°F to 1°F) lowerthan oral temperature111
As a Body Temperature ThermometerUsing the DevicePress Power Button to turn on the meter. When °C or °F blinks, temperature can be measured.Press Setting Button to select Body Mode.  If you started with Object Mode.Move the probe close to the forehead.Make sure the probe is at , with 5 - 10 cm distance from the center of forehead.Press Measure/ Memory Button to read the result.The meter will take measurement automatically.The reading is shown togetherwith blue backlight and 1 long beep.Next Reading.About 3 seconds afterwards (when a short beep is heard), °C or °F blinks again, and next temperature measurement can be taken.1.2.3.4.5.PERFORM THE TEST12
NOTE:˙As the forehead measurement temperature is likely to be aected     by sweat, oil and the surroundings, the reading shall be taken as a     reference only.˙If the probe is placed at an angle close to the forehead measure-    ment, the reading will be aected by surrounding temperature.     Babies’ skin reacts very quickly to the ambient temperature.     Therefore, do not take their temperature with the NC100     thermometer during or after breastfeeding, because the skin     temperature may then be lower than the internal body     temperature.˙If the reading is < 32°C (89.6°F), the display will show together with     red backlight and two short beeps.˙If the reading is ≥ 37.8 °C (100°F) and < 43°C (109.4°F), the display     will show together with red backlight and four short beeps.˙The thermometer will automatically turn o if left idle for 60     seconds.13
As an Object Measurement ThermometerPress Power Button to turn on the meter. When °C or °F blinks, temperature can be measured.Press Setting Button to select Object Mode.  If you started with Body Mode.Move the probe close to the object.Make sure the probe is at , not at an angle. with 5 - 10 cm distance from the object.Press Measure/ Memory Button to read the result.The meter will take measurement automatically.The reading is shown togetherwith blue backlight and 1 long beep.Next Reading.About 3 seconds afterwards (when a short beep is heard), °C or °F blinks again, and next temperature measurement can be taken.1.2.3.4.5.14
METER MEMORYRecalling the MemoryYour thermometer stores 32 most recent forehead readings1. Be sure the thermometer is OFF before     recalling this memory.2. Press Measure / Memory Button to      enter the memory  mode.Each time you press the Measure / Memory Button, a result will be displayed in the order of dates (latest result shown rst), together with ”        ” and number (from 1 to 32).Backlight in blue or red will appear according to the memory reading.When the memory is full, the oldest result is deleted as the new one added. When the last record displays on the screen, press Measure / Memory Button again to return to the rst record.Exit the memory.Press Power Button to exit the memory or keep the meter in idle for 60 seconds to switch o automatically. 3. 15
˙The probe is not waterproof. Please wipe with a clean and dry     cotton swab to clean the probe surface.˙The body of the thermometer is not water-resistant. Never put     the thermometer under a running tap or submerge it into water.     Use a soft and dry cloth to clean it. Do not use abrasive cleaners.˙Store the thermometer in a cool and dry location. Free from dust     and away from direct sunlight.Care and CleaningMAINTENANCE16
SYSTEM TROUBLESHOOTINGMeasurement ResultMeasured temperature falls outside the displayed temperature range of 32°C to 43°C (89.6°F to 109.4°F), is shown on the display with red backlight.˙Hi-temperature ≥ 43°C (109.4°F)˙Lo-temperature < 32°C (89.6°F)Measured temperature falls in normal reading, within the range of 32°C to 37.8°C (89.6°F to 100°F), is shown on the display with blue backlight.Measured temperature falls in fever reading, ≥ 37.8°C (100°F) and < 43°C (109.4°F), is shown on the display with red backlight.MESSAGE WHAT IT MEANS17
The table below shows problems you may encounter. All error messages below would be shown together with backlight. Please follow "WHAT TO DO" to resolve problems. If the problem still exists, please call your local dealer for help.Appear when environmental temperature is below/above system operation range.Put the thermometer under operating temperature range of 10°C to 40°C (50°F to 104°F).Please replace batteries as soon as possible.Please contact the customer service line.If the thermometeris broken or aected by EMF.TroubleshootingMESSAGE WHAT IT MEANS WHAT TO DOBattery is low and  "         " appears on display.18
SYMBOL INFORMATIONConsult instructions for useManufacturerSerial NumberCaution, consult accompanying documents CE markAuthorised Representative in the European CommunityType BF EquipmentDo not use if package is damaged 19
185.1mm(L) x 58mm(W) x 29.1mm(H)93g (include 2 x1.5V AAA batteries)2 x 1.5 V AAA alkaline batteriesForehead: 32.0°C to 42.9°C(89.6°F to109.2°F)Object: 0.0°C to 100.0°C(32.0°F to 212.0°F)0.1°C/0.2°F±0.2°C / 0.4 °F (32.0 ~ 42.9°C / 89.6~ 109.2  °F )±1.0°C / 2.0 °F (0.0 ~ 100.0°C / 32.0 ~ 212.0 °F )°C or °F10°C to40°C(50.0°F to 104.0°F)≦80% RH non-condensing-25°Cto55°C(-13.0°F to 131.0°F)≦95% RH non-condensing32 measurementsSPECIFICATIONSDimensionsWeightBatteryMeasuring temperature rangeDisplay resolutionAccuracyTemperature unitOperating temperature rangeOperating humidityStorage temperature rangeStorage humidityMemory capacity20
1. This product needs special precautions regarding EMC and     needs to be installed and put into service according to the EMC     information provided, and this unit can be aected by portable     and mobile RF communications equipment.2. Do not use a mobile phone or other devices that emit     electromagnetic elds, near the unit. This may result in incorrect     operation of the unit.3. Caution: This unit has been thoroughly tested and inspected to     assure proper performance and operation!4. Caution: this machine should not be used adjacent to or     stacked with other equipment and that if adjacent or stacked     use is necessary, this machine should be observed to verify       normal operation in the conguration in which it will be used.The NC100 use RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.The NC100 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.STATEMENTS AND DECLARATIONS:Guidance and manufacture’s declaration – electromagnetic emissionEmission test Compliance Electromagnetic environment – guidanceThe NC100 is intended for use in the electromagnetic environment specied below. The customer of the user of the NC100 should assure that it is used in such an environment.RF emissionsCISPR 11 Group 1Group BRF emissionCISPR 1121
Floors should be wood, concrete or ceramic tile. If oors are covered with synthetic material, the relative humidity should be at least 30%.Guidance and manufacture’s declaration – electromagnetic immunityImmunity test IEC 60601 test levelCompliance levelElectromagnetic environment - guidanceThe NC100 is intended for use in the electromagnetic environment specied below. The customer or the user of NC100 should assure that it is used in such an environment.NOTE   UT is the a.c. mains voltage prior to application of the test level.Electrostatic discharge (ESD)IEC 61000-4-2±6 kV contact±8 kV air±6 kV contact±8 kV airPower frequency magnetic elds should be at levels characteristic of a typical location in a typical commercial or hospital environment.Power frequency (50Hz/60Hz) magnetic eld IEC 61000-4-83 A/m 3 A/m22
DISPOSALAdhere to the applicable regulations when disposing of the device.This product must not be disposed of together with domestic waste. All users are obliged to hand in all electrical or electronic devices, regardless of whether or not they contain toxic substances, at a municipal or commercial collection point so that they can be disposed of in an environmentally acceptable manner.Please remove the batteries before disposing of the device/unit.Do not dispose of old batteries with your household waste, but at a battery collection station at a recycling site or in a shop.23
The statements should be displayed in the user manual:changes or modifications not expressly approved by the party responsiblefor compliance could void the user’s authority to operate the equipment.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-- Reorient or relocate the receiving antenna.-- Increase the separation between the equipment and receiver.-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-- Consult the dealer or an experienced radio/TV technician for help.The statements should be displayed in the user manual:changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.24
˙˙˙WARRANTYTyson Bioresearch, Inc. oers a 2 years guarantee on this product excluding batteries. Our company shall repair or replace any Tyson Bio Bluetooth Non-Contact Infrared Thermometer found defective with a new one.This warranty does not apply to the performance of a Tyson Bio Bluetooth Non-Contact Infrared Thermometer that has been accidentally damaged, altered, misused, tampered with or abused in any way. In no event shall our company be liable to the purchaser or any other person for any incidental, consequential, or punitive damages arising from or in any way connected with the purchase or operation of Tyson Bio Bluetooth Non-Contact Infrared Thermometer.For manufacturer warranty services, purchaser must contact Tyson Bioresearch, Inc. for help.25
Customer Service      +886-37-585998 (8:30 ~ 17:30, Monday ~ Friday)           Medical Device Safety Service GmbHSchigraben 41, D-30175 Hannover, GermanyTyson Bioresearch, Inc.5F., No. 16, 18, 20, 22, Kedong 3rd Rd., Zhunan Township, Miaoli County 35053, Taiwanwww.tysonbio.comCopyright     2016 Tyson Bioresearch Inc.  All rights reserved.is either registered trademark or trademark of Tyson Bioresearch Inc.All product images do not reflect actual sizes.AF004-0044000N (01)Rev. date: 10/2017