Fine Offset Electronics WH32G Weather Station User Manual

Fine Offset Electronics Co., Ltd. Weather Station

User manual

Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 1  Advanced Color Wireless Weather Station   User Manual  Table of Contents 1 Introduction ............................................................................................................................... 2 2 Quick Start Guide ...................................................................................................................... 2 3 Getting Started .......................................................................................................................... 2 3.1 Parts List ........................................................................................................................... 3 3.2 Recommend Tools ............................................................................................................ 3 3.3 Thermo-Hygrometer Sensor Set Up ................................................................................. 4 3.4 Display Console ............................................................................................................... 5 3.4.1 Display Console Layout ................................................................................................... 5 3.4.2 Display Console Set Up ............................................................................................... 6 3.4.3 Display Console Set Up ............................................................................................... 6 3.5 Sensor Operation Verification .......................................................................................... 7 3.6 Sensor Placement ............................................................................................................. 8 3.7 Best Practices for Wireless Communication .................................................................... 8 4 Console Operation..................................................................................................................... 9 4.1 Set Mode .......................................................................................................................... 9 4.1.1 Time Zones ................................................................................................................. 10 4.2 Barometric Pressure ....................................................................................................... 11 4.2.1 Barometric Pressure History ...................................................................................... 11 4.2.2 Relative vs. Absolute Pressure ................................................................................... 11 4.3 Dew Point ....................................................................................................................... 12 4.4 Alarms ............................................................................................................................ 12 4.4.1 View Alarm Time ....................................................................................................... 12 4.4.2 Time Alarm Settings Mode ........................................................................................ 12 4.4.3 Cancelling the Alarm .................................................................................................. 13 4.4.4 Low Temperature Alarm ............................................................................................ 13 4.5 Calibration ...................................................................................................................... 13 4.6 Max/Min Mode .............................................................................................................. 14 4.7 Other Console Features .................................................................................................. 15 4.7.1 Display Brightness ..................................................................................................... 15 4.7.2 Weather Forecasting ................................................................................................... 15 4.7.3 Weather Forecasting Description and Limitations ..................................................... 16 4.7.4 Moon Phase ................................................................................................................ 16 4.7.5 Pressure Tendency Arrows ......................................................................................... 16 4.7.6 Rate of Change of Pressure Graph ............................................................................. 16 4.7.7 Resynchronizing Lost Sensor ..................................................................................... 17 5 Glossary of Terms ................................................................................................................... 18 6 Specifications .......................................................................................................................... 18
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 2  6.1 Wireless Specifications .................................................................................................. 18 6.2 Measurement Specifications ........................................................................................... 19 6.3 Power Consumption .............................................................................................................. 19 7 Troubleshooting Guide ............................................................................................................ 19 8 Accessories ............................................................................................................................. 21 9 Liability Disclaimer ................................................................................................................ 21 10 FCC Statement .................................................................................................................... 21 11 Warranty Information ......................................................................................................... 22  1 Introduction Thank  you  for  your  purchase  of  the  Weather  WH2802  Wireless  Color  Weather  Station.  The following  user  guide  provides  step  by  step  instructions  for  installation,  operation  and troubleshooting.      The features:  Wireless outdoor and indoor humidity (%RH)  Wireless outdoor and indoor temperature (°F or °C)    Records min. and max. humidity  Records min. and max. temperature  Barometric pressure (inHg or hPa)  Weather forecast    Radio controlled (WWVB) automatic date and time or manual date and time  12 or 24-hour time display    Perpetual calendar    Time alarm with snooze  Moon phase  LED color backlight    Wall hanging or free standing 2 Quick Start Guide Step Description Section 1 Power up Remote Sensor 3.3 2 Power Up Display Console 3.4 3 Set Up or Program Display Console 4.1 4 Install Sensor 3.6 5 Calibrate Barometer 4.2 and 4.5 3 Getting Started The weather station consists of a display console (receiver), thermos-hygrometer sensor and AC adapter.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 3    Note: The power up sequence must be performed in the order shown in this section (remote transmitter first, display console second) to properly synchronize the remote sensor to the console. 3.1 Parts List QTY Item Image 1 Display Console   Frame Dimensions (LxHxW): 6.36 x 3.39 x 0.86”   (161.5 x 86 x 21.5 mm)   1 Thermo-hygrometer transmitter (?) Dimensions (LxHxW): 4.80 x 1.57 x 0.71”   (122 x 40 x 18 mm)  1 Manual  1 Power Adapter  Figure 1 3.2 Recommend Tools  Hammer and nail for hanging remote thermo-hygrometer transmitter.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 4  3.3 Thermo-Hygrometer Sensor Set Up Remove the battery door on the back of the sensor, as shown in Figure 2.     Figure 2   1. Insert two AA batteries.  2. After inserting the batteries, the remote sensor will display temperature and humidity on the display, as shown in Figure 3.  Figure 3  3. Close the battery door. Note:    We recommend lithium batteries for cold weather climates, but alkaline batteries are  sufficient  for  most  climates.  We  do  not  recommend  rechargeable  batteries.  They  have lower  voltages,  do  not  operate  well  at  wide  temperature  ranges,  and  do  not  last  as  long, resulting in poorer reception.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 5  4. Replace the battery door. 3.4 Display Console 3.4.1 Display Console Layout The display console layout is shown in Figure 4.  Figure 4  1. Daylight Savings Time 13.    Outdoor humidity 2. Radio controlled reception 14.    Outdoor humidity 3. Time 15.    Min indoor humidity 4.    Week day 16.    Max indoor humidity 5.    Date 17.    Min indoor temperature 6.    Moon phase 18.    Max indoor temperature 7.    Pressure rate of change 19.    Indoor temperature 8.    Barometric pressure 20.    Min outdoor temperature 9.    Barometric pressure trend arrow 21.    Max outdoor temperature 10.    Outdoor humidity 22.    Outdoor temperature 11.    Min outdoor humidity 23.    Transmitter signal strength 12.    Max outdoor humidity 24.    Weather forecast icon based on barometer
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 6  3.4.2 Display Console Set Up     Figure 5  3.4.3 Display Console Set Up Place the  remote thermo-hygrometer about 5 to  10  feet  away  from  the  display  console  (if  the sensor is too close, it may not be received by the display console).  1. Insert the power adapter into the power jack of the console, and plug in the adapter. The LCD display will beep once and then light up. The brightness selection is set to high when plugged into the adapter.    2. Remove the battery door on the back of the display. Insert three AAA (alkaline or lithium, avoid rechargeable) batteries in the back of the display console. Looking at the back of the unit (left to right), the polarity is (+) (-) for the top battery, (-) (+) for the middle battery and (+) (-) for the bottom battery.   Note:  To  avoid  permanent  damage,  please  take  note  of  the  battery  polarity  before inserting the batteries.  3. Replace the battery door,  and fold  out  the desk  stand and place the  console in  the upright position, as shown in Figure 5.    Note: The batteries are intended for back-up power only.    The backlight will remain on for 5 seconds when on back up battery power only.    Only when you use power adapter it will the back-light be continuously on.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 7   4. After initialization, the console will instantly display indoor temperature, humidity, barometer, moon phase, date and time.    The remote search icon will turn on:  Do not touch any buttons until the remote sensor reports in, otherwise the remote sensor search mode will be terminated and the search icon will turn off. When the remote sensor data has been received, the console will automatically switch to the normal mode, and all further settings can be performed.  3.4.4 Radio Controlled Clock (RCC)  Your console is equipped with the Radio Controlled Clock (RCC). The icon WWVB will appear above the time to signify this.    The  RCC  is  received  by  the  wireless  transmitter,  and  passed  to  the  console.  After  the  remote sensor is powered up, the sensor will transmit weather data for 30 seconds, and then the sensor will begin radio controlled clock (RCC) reception.    During  the  RCC  time  reception  period  (maximum  10  minutes),  no  weather  data  will  be transmitted to avoid interference.    If the signal reception is not successful (normally during the day due to solar interference), the sensor search will be cancelled, the outdoor temperature and humidity will update as normal, and the RCC search will automatically resume every two hours until the signal is successfully captured. The regular RF link will resume once RCC reception routine is finished. In some locations, RCC reception may take a couple of days to receive the signal. The temperature and humidity data will continue to transmit during this period. Once the radio controlled time is received, the RCC reception icon    will turn on (reference Figure 4). 3.5 Sensor Operation Verification Verify the indoor and outdoor humidity match closely with the console and sensor array in the same location (about 10’ apart). The sensors should be within 10% worst case (the accuracy is ± 5%).    Allow about 30 minutes for both sensors to stabilize.  Verify the indoor and outdoor temperature match closely with the console and sensor array in the same location (about 10’ apart). The sensors should be within 4°F worst case (the accuracy is ± 2°F).    Allow about 30 minutes for both sensors to stabilize.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 8  3.6 Sensor Placement It is recommended you mount the remote sensor outside on a north facing wall, in a shaded area, at a height at or above the receiver. If a north facing wall is not possible, choose a shaded area, under an eve.  Direct sunlight and radiant heat sources will result in inaccurate temperature readings. Although the sensor is weatherproof, it is best to mount in a well-protected area, such as an eve.  1. Use a screw or nail to affix the remote sensor to the wall, as shown in Figure 6. 2. Hang the remote sensor up on string, as shown in Figure 7.   Note: Make sure the sensor is mounted vertically and not lying down on a flat surface. This will  insure  optimum  reception.  Wireless  signals  are  impacted  by  distance,  interference  (other weather stations, wireless phones, wireless routers, TVs and computer monitors), and transmission barriers, such as walls. In general, wireless signals will not penetrate solid metal and earth (down a hill, for example).    Figure 6 Figure 7 3.7 Best Practices for Wireless Communication Wireless communication is susceptible to interference, distance, walls and metal barriers. We recommend the following best practices for trouble free wireless communication.   1. Electro-Magnetic Interference (EMI). Keep the console several feet away from computer monitors and TVs.  2. Radio Frequency Interference (RFI). If you have other 915 MHz devices and communication is intermittent, try turning off these other devices for troubleshooting purposes. You may need to relocate the transmitters or receivers to avoid intermittent communication.  3. Line of Sight Rating. This device is rated at 300feet line of sight (no interference, barriers or walls) but typically you will get 100feet maximum under most real-world installations, which include passing through barriers or walls.  4. Metal Barriers. Radio frequency will not pass through metal barriers such as aluminum siding. If
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 9  you have metal siding, align the remote and console through a window to get a clear line of sight.  The following is a table of reception loss vs. the transmission medium. Each “wall” or obstruction decreases the transmission range by the factor shown below.   Medium RF Signal Strength Reduction   Glass (untreated) 5-15% Plastics 10-15%   Wood 10-40%   Brick 10-40%   Concrete 40-80%   Metal 90-100% 4 Console Operation Note: The console has four keys for easy operation: TEMP/+ key, ALARM key, BARO/- key and SET key. There are four program modes: Set Mode, Alarm Mode, Calibration Mode and Min/Max Mode.  Any program mode can be exited at any time by either pressing the SNOOZE/LIGHT key (on the top of the display console), or waiting for the 30-second time-out to take effect. 4.1 Set Mode The Set Mode allows you to change date, time, units of measure and other important functions, as referenced in Figure 8.      To enter the Set Mode, press and hold the SET key for two seconds (SET + 2 seconds). To advance each command, press (do not hold) the SET key.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 10  Command Function Description Settings SET + 2 seconds BEEP Turns  on  or  off  the  beep  with each keystroke Press TEMP/+ or BARO/- to toggle OFF and ON SET RST Reset  max/min  daily  at 12:00am (on) or manually (off) Press TEMP/+ or BARO/- to toggle OFF and ON SET ZON Time Zone (TZ)   Press TEMP/+ to increase or BARO/- to decrease (reference Figure 9). SET DST Observe  Daylight  Savings Time  (set  to  OFF  in  Arizona and  Hawaii,  ON  everywhere else) Press TEMP/+ or BARO/- to toggle OFF and ON SET 12H 12/24 Hour Format Press TEMP/+ or BARO/- to toggle between 12 hour (12h) and 24 hour (24h) format SET HR Hour of Day Press TEMP/+ to increase. BARO/- to decrease SET MIN Minute of Day Press TEMP/+ to increase. BARO/- to decrease SET M-D Month Day Format Press TEMP/+ or BARO/- to toggle between M-D (month/day) format and D-M (day/month) format SET Y Year Press TEMP/+ to increase and BARO/- to decrease SET M Month of Year Press TEMP/+ to increase and BARO/- to decrease SET D Day of Month Press TEMP/+ to increase and BARO/- to decrease SET °F Temperature Units of Measure Press TEMP/+ to toggle between °F and °C SET inHg Barometric  Pressure  Units  of Measure Press TEMP/+ to toggle between inHg and hPa SET NTH Northern Hemisphere (NTH) or southern  Hemisphere  (STH) select Press TEMP/+ to toggle between Northern and southern Hemisphere SET  Exit Set Mode  Figure 8 4.1.1 Time Zones Hours from GMT Time Zone Cities -12 IDLW: International Date Line West ---
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 11  Hours from GMT Time Zone Cities -11 NT: Nome Nome, AK -10 AHST: Alaska-Hawaii Standard CAT: Central Alaska HST: Hawaii Standard Honolulu, HI -9 YST:   Yukon Standard Yukon Territory -8 PST: Pacific Standard Los Angeles, CA, USA -7 MST: Mountain Standard Denver, CO, USA -6 CST: Central Standard Chicago, IL, USA -5 EST: Eastern Standard New York, NY, USA -4 AST: Atlantic Standard Caracas -3 --- São Paulo, Brazil -2 AT: Azores Azores, Cape Verde Islands -1 WAT: West Africa --- 0 GMT: Greenwich Mean WET: Western European London, England 1 CET: Central European Paris, France 2 EET: Eastern European Athens, Greece 3 BT: Baghdad Moscow, Russia 4 --- Abu Dhabi, UAE 5 --- Tashkent 6 --- Astana 7 --- Bangkok 8 CCT: China Coast Bejing 9 JST: Japan Standard Tokyo 10 GST: Guam Standard Sydney 11 --- Magadan 12 IDLE: International Date Line East NZST: New Zealand Standard Wellington, New Zealand Figure 9 4.2 Barometric Pressure 4.2.1 Barometric Pressure History While in normal mode, press BARO/- to check the barometric pressure history. Press the BARO/- button to  switch to  past  12hr/24hr/48hr/72hr average  pressure. To  exit  the  barometric pressure history mode, press  the SNOOZE/LIGHT key (on the top  of the display console), or wait 30 seconds for the timeout to take effect. 4.2.2 Relative vs. Absolute Pressure While  in  normal  mode,  Press  and  hold  the  BARO/-  button  for  2  seconds  to  switch  between
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 12  absolute (ABS) pressure and relative (REL) pressure. Note: The display console displays two different pressures: absolute (measured) and relative (corrected to sea-level).  To compare pressure conditions from one location to another, meteorologists correct pressure to sea-level  conditions.  Because  the  air  pressure  decreases  as  you  rise  in  altitude,  the  sea-level corrected  pressure  (the  pressure  your  location  would  be  at  if  located  at  sea-level)  is  generally higher than your measured pressure.  Thus, your absolute pressure may read 28.62 inHg (969 mb) at an altitude of 1000 feet (305 m), but the relative pressure is 30.00 inHg (1016 mb).  The standard sea-level pressure is 29.92 in Hg (1013 mb). This is the average sea-level pressure around  the  world.    Relative  pressure  measurements  greater  than  29.92  inHg  (1013  mb)  are considered high pressure and relative pressure measurements less than 29.92 inHg are considered low pressure.  To determine the relative pressure for your location, locate an official reporting station near you (the  internet  is  the  best  source  for  real  time  barometer  conditions,  such  as  Weather.com  or Wunderground.com), and set your weather station to match the official reporting station.  To calibrate the relative pressure to a local airport, please reference Section 4.5. 4.3 Dew Point While in normal mode, Press the TEMP/+ key to view the Dew Point in the outdoor temperature field. If key idle 30 seconds, the display will return to normal mode.  To exit the Dew Point display mode, press the SNOOZE/LIGHT key (on the top of the display console), or wait 30 seconds for the timeout to take effect. 4.4 Alarms 4.4.1 View Alarm Time While in normal mode, press the ALARM key to view the alarm time. The alarm icon will be displayed in the time field. 4.4.2 Time Alarm Settings Mode To enter the Alarm Mode, press and hold the ALARM key for two seconds (ALARM + 2 seconds). To advance each command, press (do not hold) the SET key.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 13  Command Function Description Settings ALARM + 2 seconds Alarm Hour Set the Alarm Hour Time Press TEMP/+ or BARO/- to increase or decrease the alarm hour. SET Alarm Minute Set the Alarm Hour Minute Press TEMP/+ or BARO/- to increase or decrease the alarm minute. SET ALARM ON/OFF Turn  the  Time  Alarm  On  or Off.   Press TEMP/+ to toggle between Time Alarm ON and Time Alarm Off SET LOW Alarm Turn  the  LOW  Temperature Alarm On or Off Press TEMP/+ to toggle between Time Alarm ON and Time Alarm Off SET  Exit Set Mode  Figure 10 4.4.3 Cancelling the Alarm If the time alarm sounds, press the any key to silence the alarm. Press the LIGHT/SNOOZE key to enter snooze mode.  The  low  temperature  alert  will  reset  automatically  once  the  value  has  fallen  into  the  low temperature alert range. 4.4.4 Low Temperature Alarm The low temperature alarm sounds when the outdoor is between -3 °C and +2 °C (26.6 °F and 35.6 °F). The LO temperature icon    will appear and flash on the console. If the BEEP is switched on, an audible alert will also activated when the low temperature alert occurs.  Figure 11 4.5 Calibration While in the normal node, press and hold the SET and BARO/- keys for five seconds to enter calibration mode (note: the SET mode will appear after three seconds. Continue pressing the two keys until you see the CAL icon appear in the upper right hand corner of the display).  Enter the calibration offset to match the calibration source.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 14  Command Function Description Settings SET and BARO/- + 5 seconds OUTDOOR TEMP Calibrate the outdoor temperature Press TEMP/+ or BARO/- to increase or decrease the outdoor temperature offset. SET OUTDOOR HUMIDITY Calibrate the outdoor humidity Press TEMP/+ or BARO/- to increase or decrease the outdoor humidity offset. SET INDOOR TEMP Calibrate  the  indoor temperature Press TEMP/+ or BARO/- to increase or decrease the indoor temperature offset. SET INDOOR HUMIDITY Calibrate the outdoor humidity Press TEMP/+ or BARO/- to increase or decrease the indoor humidity offset. SET PRESSURE Calibrate the relative pressure Press TEMP/+ or BARO/- to increase or decrease relative pressure offset. SET  Exit Set Mode  Figure 12 Example 1: The calibrated temperature from a red spirit thermometer, or actual temperature is 60.0 °F. The uncalibrated or measured temperature is 58.7 °F. Offset = Calibrated Temperature – Uncalibrated Temperature = 60.0 – 58.7 = 1.3 °F. Enter the temperature offset +1.3 °F.  Example 2: The calibrated relative pressure at the local airport is 29.86 inHg. The uncalibrated or measured relative pressure measured by the weather station is 29.92 inHg. Offset = 29.86 – 29.92 = -0.06 inHg Enter the relative pressure offset -0.06 inHg  To exit the calibration mode at any time, press the LIGHT/SNOOZE button.  Note: The calibration offset range limits are as follows: Temperature: ± 9°F Humidity: ± 9% Relative: ± 10hpa (± 0.295 inHg)  4.6 Max/Min Mode The Max/Min data is displayed below each parameter.  The  orange parameter on  the left is the maximum value since the last reset, and the blue parameter on the left is the minimum value since the last reset.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 15   Figure 13  To  clear  all  of  the  MAX/MIN  records,  press  and  hold  the  TEMP/+ button  for  three  seconds. Dashes will be displayed until the next update.  MAX/MIN  records  are  cleared  automatically  at  midnight.  The  MAX/MIN  DAILY  icon     will be displayed. To switch this feature off, reference Section 4.1. 4.7 Other Console Features 4.7.1 Display Brightness Press the LIGHT/SNOOZE button to toggle the screen brightness between HIGH, MEDIUM and LOW. 4.7.2 Weather Forecasting  The five weather icons are Sunny, Partly Cloudy, Cloudy, Rainy and Stormy.  The forecast icon is based on the rate of change of barometric pressure. Please allow at least one month for the weather station to learn the barometric pressure over time.  Sunny Partly Cloudy Cloudy Rainy Stormy      Pressure increses for  a  sustained period of time Pressure increases slightly, or initial power up Pressure decreases slightly Pressure decreases  for  a sustained  period of time Pressure  rapidly decreases Figure 14
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 16  4.7.3 Weather Forecasting Description and Limitations In general, if the rate of change of pressure increases, the weather is generally improving (sunny to partly  cloudy).  If  the  rate  of  change  of  pressure  decreases,  the  weather  is  generally  degrading (cloudy, rainy or stormy). If the rate of change is relatively steady, it will read partly cloudy.  The  reason  the  current  conditions  do  not  match  the  forecast  icon  is  because  the  forecast  is  a prediction 24-48 hours in advance. In most locations, this prediction is only 70% accurate and it is a good idea to consult the National Weather Service for more accurate weather forecasts. In some locations, this prediction may be less or more accurate. However, it is still an interesting educational tool for learning why the weather changes.  The National Weather Service (and other weather services such as Accuweather and The Weather Channel) have many tools at their disposal to predict weather conditions, including weather radar, weather models, and detailed mapping of ground conditions. 4.7.4 Moon Phase The following moon phases are displayed based on the calendar date and your northern vs southern hemisphere, as shown in Figure 15.  Northern Hemisphere:            New Waxing Crescent First Quarter Waxing Gibbous Full Waning Gibbous Third Quarter Waning  New  Southern Hemisphere:            New Waxing Crescent First Quarter Waxing Gibbous Full Waning Gibbous Third Quarter Waning  New Figure 15 4.7.5 Pressure Tendency Arrows The forecast trend arrow updates every 30 minutes. The trend reflects changes in pressure (1 hPa) over the past 3 hours. Pressure is rising Pressure is unchanged Pressure is falling    Figure 16 4.7.6 Rate of Change of Pressure Graph The rate of change of pressure graphic is shown to the left of the barometric pressure and signifies the difference between the daily average pressure and the 30 day average (in hPa).
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 17   Figure 17 4.7.7 Resynchronizing Lost Sensor If the  signal is  lost between  the  remote sensor (or  transmitter) and the display console (or  the receiver), to resynchronize, while in normal mode, Press and hold SET and TEMP/+ button for 5 seconds, to register the outdoor transmitter. The sensor search icon will flash.  Please  wait  several  minutes  for  the  remote  sensor  reports  in.  Do  not  touch  any  buttons  until synchronization is complete.  If the synchronization fails, reset the console by removing one battery from the display console, disconnect from AC power, wait 10 seconds, and reinsert the battery and reconnect AC power..
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 18  5   Glossary of Terms Term Definition Accuracy Accuracy is defined as the ability of a measurement to match the actual value of the quantity being measured. Hygrometer A hygrometer is a device that measures relative humidity.    Relative humidity is a term used to describe the amount or percentage of water vapor that exists in air. Range Range is defined as the amount or extent a value can be measured. Resolution Resolution is defined as the number of significant digits (decimal places) to which a value is being reliably measured. Absolute Barometric Pressure    Relative barometric pressure, corrected to sea-level. To compare pressure conditions from one location to another, meteorologists correct   pressure to sea-level conditions. Because the air pressure decreases as   you rise in altitude, the sea-level corrected pressure (the pressure your   location would be at if located at sea-level) is generally higher than your   measured pressure.   Relative Barometric Pressure   Measured barometric pressure relative to your location or ambient     conditions.     HectoPascals (hPa) Pressure units in SI (international system) units of measurement. Same   as millibars (1 hPa = 1 mbar)   Inches of Mercury (inHg)   Pressure in Imperial units of measure.   1 inch of mercury = 33.86 millibars 6 Specifications 6.1 Wireless Specifications  Line of sight wireless transmission (in open air): 300 feet, 100 feet under most conditions  Frequency: 915 MHz  Update Rate: 60 seconds for rain sensor and thermo-hygrometer sensor, 16 seconds for wind sensor.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 19  6.2 Measurement Specifications The following table provides specifications for the measured parameters. Measurement Range Accuracy Resolution Indoor Temperature -14 to 140 °F -10 to 60 °C ± 1.8 °F ± 1 °C 0.1 °F 0.1 °C Outdoor Temperature -40 to 140 °F -40 to 60 °C ± 1.8 °F ± 1 °C 0.1 °F 0.1 °C Indoor Humidity 10 to 99 % ± 5% (only guaranteed between 20 to 90%) 1 % Outdoor Humidity 10 to 99% ± 5% (only guaranteed between 20 to 90%) 1 % Barometric Pressure 8.85 inHg to 32.48 inHg 300 hpa to 1100 hpa   ± 0.09 inHg ±3 hpa (only guaranteed between 700 to 1100hpa) 0.01 inHg 0.1hpa Figure 18 6.3 Power Consumption  Base station : 5V DC adaptor (included)                       3 x AAA 1.5V Batteries (not included)  Remote sensor : 2 x AA Batteries (not included)  Battery life:    About 12 months for base station   About 12-24  months for  thermometer-hygrometer  sensor  (use  lithium batteries  in  cold weather climates) 7 Troubleshooting Guide  Problem Solution Wireless remote (thermo-hygrometer) not reporting in to console.  There are dashes (--.-) on the display console. If any of the sensor communication is lost, dashes (--.-) will be displayed on the screen. To reacquire the signal, reference 4.7.7.  The maximum line of sight communication range is 300 feet and 100 feet under most conditions. Move the sensor assembly closer to the display console.  If the sensor assembly is too close (less than 5’), move the sensor assembly away from the display console.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 20  Problem Solution Make sure the remote sensor LCD display is working on both the console and the remote sensor.  Install a fresh set of batteries in the remote thermo-hygrometer. For cold weather environments, install lithium batteries.  Make sure the remote sensors are not transmitting through solid metal (acts as an RF shield), or earth barrier (down a hill).  Move the display console around electrical noise generating devices, such as computers, TVs and other wireless transmitters or receivers.  Move the remote sensor to a higher location. Move the remote sensor to a closer location. Temperature sensor reads too high in the day time. Make sure the thermo-hygrometer is mounted in a shaded area. The pre preferred location is a north facing wall because it is in the shade most of the day.     Indoor and Outdoor Temperature do not agree Allow up to one hour for the sensors to stabilize due to signal filtering. The indoor and outdoor temperature sensors should agree within 3.6 °F (the sensor accuracy is ± 1.8 °F).  Use the calibration feature to match the indoor and outdoor temperature to a known source. Indoor and Outdoor Humidity do not agree Allow up to one hour for the sensors to stabilize due to signal filtering. The indoor and outdoor humidity sensors should agree within 10 % (the sensor accuracy is ± 5 %).  Use the calibration feature to match the indoor and outdoor humidity to a known source. Display console contrast is weak Plug into AC power. The console was not designed to run exclusively on batteries.
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 21  8 Accessories  Accessory Description Energizer AAA Lithium Battery (2-pack) - Batteries for Long Life and Cold Climates AAA lithium batteries for cold weather climates. Weather SRS100LX Temperature and Humidity Solar Radiation Shield Solar Radiation Shield improves temperature accuracy for hot weather climates. Install over thermo-hygrometer. Weather Humidity Calibration Kits One step calibration kits for digital hygrometers use salt slurry formula to accurately calibrate the indoor and outdoor hygrometers.   9 Liability Disclaimer Please help in the preservation of the environment and return used batteries to an authorized depot.   The electrical and electronic wastes contain hazardous substances. Disposal of electronic waste in wild country and/or in unauthorized grounds strongly damages the environment.  Reading the “User manual” is highly recommended. The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place.  This  product  is  designed  for  use  in  the  home  only  as  indication  of  weather  conditions.  This product is not to be used for medical purposes or for public information.  The specifications of this product may change without prior notice.  This product is not a toy. Keep out of the reach of children.  No part of this manual may be reproduced without written authorization of the manufacturer.  10   FCC Statement Statement according to FCC part 15.19:   This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:   1. This device may not cause harmful interference.   2. This device must accept any interference received, including interference that may cause undesired operation.   Statement according to FCC part 15.21:
Receiver Model : WH2802 Sensor Model : WH32G Version 1.0             Page 22  Changes or modifications not expressly approved by this company could void the user's authority to operate the equipment. Statement according to FCC part 15.105:   NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.   However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   • Reorient or relocate the receiving antenna.   • Increase the separation between the equipment and receiver.   • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   • Consult the dealer or an experienced radio/TV technician for help.   11   Warranty Information We provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship.  This limited warranty begins on the original date of purchase, is valid only on products purchased and only to the original purchaser of this product.    Warranty covers all defects in material and workmanship with the following specified exceptions: (1) damage caused  by accident,  unreasonable use or  neglect (lack of  reasonable and  necessary maintenance); (2) damage resulting from failure to follow instructions contained in your owner’s manual; (3)  damage resulting from the performance of repairs  or alterations by  someone other than an authorized service center; (4) units used for other than home use (5) applications and uses that this product was not intended (6) the products inability to receive a signal due to any source of interference  or  metal  obstructions  and  (7)  extreme  acts  of  nature,  such  as  lightning  strikes  or floods.    This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation  by  the  seller  or  performance  variations  resulting  from  installation-related circumstances.