Feig Electronic CVEND Contactless Payment and Ticketing Module User Manual Installation ID CPR46 10

Feig Electronic GmbH Contactless Payment and Ticketing Module Installation ID CPR46 10

Contents

Installation Instruction 2

   INSTALLATION  Preliminary Confidential 2015-02-20 - cVEND plug - User manual.docx  cVEND plug Contactless Payment and Ticketing Module
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 2 of 24 cVEND plug - User manual.docx  Note  Copyright 2014 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. Composition  of  the  information  in  this  document  has  been  done  to  the  best  of  our  knowledge.  FEIG ELECTRONIC  GmbH  does  not  guarantee  the  correctness  and  completeness  of  the  details  given  in  this manual and may not be held liable for  damages  ensuing  from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG  ELECTRONIC  GmbH  assumes  no  responsibility  for  the  use  of  any  information  contained  in  this document and makes  no representation that they free of patent  infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.  All brand names, trademarks or logos are property of their respective owners.    Contact: Commercial Questions:  cvend@feig.de Technical Questions:  cvend-support@feig.de
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 3 of 24 cVEND plug - User manual.docx  Contents 1. Warnings - Read before start-up !  4 1.1. Safety Instructions ............................................................................................................ 4 1.2. Security Instructions ......................................................................................................... 4 2. Characterization  5 3. Mechanical Integration  7 3.1. Dimensions ........................................................................................................................ 9 4. Connection  10 4.1. Connector X1 - Ethernet Interface .................................................................................. 11 4.2. Connector X2 - USB Device Interface ............................................................................ 12 4.3. Connector X3 - RS232 V.24 (UART#1) Interface ............................................................ 13 4.4. Connector X4 - RS232-LVTTL (UART#0) Interface ........................................................ 14 4.5. Connector X5 – Power Supply Vcc ................................................................................. 15 4.6. Wake-Up ........................................................................................................................... 16 4.7. Connector X6, X11, X12 - Extension Interfaces ............................................................. 17 4.7.1. Connector X6 - RGB Display (cVEND plug flex only) ................................................. 17 4.7.2. Connector X11 - SAM and SD Interface ..................................................................... 18 4.7.3. Connector X12 - Auxiliary Interfaces .......................................................................... 18 5. Technical Data  19 5.1. Standard Compliance ...................................................................................................... 20 5.2. Radio Approvals .............................................................................................................. 20 5.2.1. Europe (CE) ............................................................................................................... 20 5.2.2. USA (FCC) and Canada (IC) ...................................................................................... 21 6. cVEND plug SAM Extension - Option  23
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 4 of 24 cVEND plug - User manual.docx  1. Warnings - Read before start-up ! 1.1. Safety Instructions  The  device  may  only  be  used  for  the  intended  purpose  designed  for  by  the manufacturer.  The operation manual should be conveniently kept available at all times for each user.  Unauthorized changes and the use of spare parts and additional devices which have not been  sold  or  recommended  by  the  manufacturer  may  cause  fire,  electric  shocks  or injuries. Such unauthorized measures shall  exclude any liability by the manufacturer.  The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are  valid  for  the  device.  The  manufacturer  shall    not  be  held  legally  responsible  for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or  for an incorrect application of a device.  Repairs may only be executed by the manufacturer.  Installation,  operation,  and  maintenance  procedures  should  only  be  carried  out  by qualified personnel.  Use  of  the  device  and  its  installation  must  be  in  accordance  with  national  legal requirements and local electrical codes .  When working on devices the valid safety regulations must be observed.  Special advice for carriers of cardiac pacemakers: Although  this  device  doesn't  exceed  the  valid  limits  for  electromagnetic  fields  you should keep a minimum distance of 25 cm between the device and your cardiac pace-maker and not stay in an immediate proximity of the device respective the antenna for some time.   1.2. Security Instructions  DO  NOT  DISASSEMBLE  ANY  PART!  The  device  contains  a  battery-powered  security circuited.  The  security  circuit  will  be  triggered  if  security  relevant  parts  are disassembled. In such cases the device stops regular operation and can be reactivated only by the manufacturer in a certified secure environment.
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 5 of 24 cVEND plug - User manual.docx  2. Characterization The cVEND plug is a secure contactless module for contactless credit cards (open-loop) and public transport tickets (closed-loop). It fulfills the  newest functional and security related  payment  card industry standards. cVEND plug is designed for flush integration into non conducting housings. It is EMVCo contact-less certified, if installed according the guidelines described in this manual.  cVEND plug is available in two versions:   cVEND plug flex The cVEND plug flex is a flexible secure platform to develop a payment and ticketing solution. Due to the variety of interfaces and the open SDK cVEND plug flex  can  be  the  core  element  for  a  terminal.  direct connection  of  color  or  monochrome displays,  touch screens, external scanners or other peripheral com-ponents are possible.      cVEND plug reader The  cVEND  plug  reader  is  a  secure  contactless reader for payment and ticketing applications which includes  an  EMVCo  contactless  Level  2  kernel  for credit  card  processing.  The  cVEND  plug  reader  of-fers an easy to use secure protocol and can be used in  payment  mode  as  well  as  in  transparent  card reader  mode  which  makes  it  suitable  for  payment and ticketing applications.
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 6 of 24 cVEND plug - User manual.docx    Fig. 1: cVEND plug front view - not installed      Fig. 2: cVEND plug rear view - not installed  Table 1: Interfaces and connectors Label Description 1 LEDs (4 x green, 1 x yellow, 1 x red)  2 From outside visible, illuminated plastic dome “Plug” X1 Ethernet Interface (10 / 100 Base-T network port) X2 USB Device Interface X3 RS232 V.24 (UART#1) Interface X4 RS232-LVTTL (UART#0) Interface X5 Power Supply 5V DC X6 Connector for RGB Display (cVEND plug flex only) X11 Connector for SAM / SD-Card Extension Board X12 Connector for Auxiliary Interfaces  1 2 X11 X2 X1 X6 X12 X4 X5 X3
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 7 of 24 cVEND plug - User manual.docx  3. Mechanical Integration For flush integration into non conducting housings one round opening with a diameter of 28,5 mm  is neces-sary to show the back-lit contactless symbol. cVEND plug is installed from inside the housing. cVEND plug is designed for front plates with 3 mm thickness. cVEND plug has to installed from inside the housing. If the LEDs of cVEND plug shall be used, additional light channels are to be provided.    NOTICE To comply with EMVCo regulations:  The contactless logo must be visible.  The upper edge of the cVEND plug plastic dome and the target terminal front plate must be on the same level.  Avoid any kind of conducting material surrounding the cVEND plug.  Do not use conducting materials for fastening.  The following figure shows cross-sectional view of cVEND plug plastic dome (1) flush installed into target terminal front plate (2)  Fig. 3: cVEND plug (1) installed in front plate (2) - cross-sectional view 2 1
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 8 of 24 cVEND plug - User manual.docx  The cVEND plug front consists of a silicon rubber mat (1) with integrated sealing (2) and a fixed poly carbonate plastic dome (3) which shows the back-lit contactless symbol.   Fig. 4: Plug front with sealing (red colored) For fastening the cVEND plug front has to be pressed tight against the housing front. Therefore a clamp range of 2,5 mm (fastening area) on all sides of the cVEND plug antenna PCB is available. The following figure shows the clamp range (red marked). The picture on the left side shows the back view, the picture on the right side is perspective view. For detailed dimension see Chapter 3.1. Dimensions. 3D STEP Data are available on request.    Fig. 5:  cVEND plug fastening area (red marked)   1 3 2
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 9 of 24 cVEND plug - User manual.docx  3.1. Dimensions    Fig. 6: cVEND plug front with LED position   Fig. 7:  cVEND plug rear and side view (without cVEND SAM Extension Board)
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 10 of 24 cVEND plug - User manual.docx  4. Connection The connector I/O PINs are described from the cVEND plug view. A cVEND plug input must be connected to one output or vice versa.  Fig. 8: cVEND plug - connector location  Fig. 9:  cVEND plug with optional SAM Extension Board SAM1 SAM2 SAM3 SAM4 µSD X6 1 38 38 1 6  5  4 3  2  1 4  3 2  1 2 1 1  2  3  4  5  6 X1 X11 X2 X3 X4 X5 X12 1 38
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 11 of 24 cVEND plug - User manual.docx  4.1. Connector X1 - Ethernet Interface cVEND has an integrated 10 / 100 Base-T network port at RJ45 connector X1, with automatic po-larity correction during auto-negotiation and 10 Base-T signal reception.  CAT 5 cables are recommended to ensure a reliable operation at 10 Mbps or 100 Mbps.   Fig. 10: Ethernet Interface at connector X1  Required Connector:  RJ45 Table 2: Pin Assignment Ethernet Connector PIN Label 1 TX+ 2 TX- 3 RX+ 4 VETH+ 5 VETH+ 6 RX- 7 VETH- 8 VETH-
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 12 of 24 cVEND plug - User manual.docx  4.2. Connector X2 - USB Device Interface At connector X2 a USB-Device interface is provided where USB-Host can be connected. cVEND is designed as a self powered device. powering over USB interface is not possible.  Fig. 11: USB Interface at connector X2  Required Connector: The fitting complement for this connector consists of a 6-pole plug Type Molex Micro Fit and the appending Crimp contact.  Manufacturer ordering code: Molex 43025-0600 Plug,  6-pole, grid dimension 3.0 mm, Dual Row, Molex Micro Fit housing Molex 43030-0001 Crimp contact, Female, grid dimension 3.0 mm, AWG#20-24, Molex Micro Fit  Table 3: Pin Assignment USB Connector PIN Label Direction 1 DEV-Vcc I 2 DEV-D- I/O 3 DEV-D+ I/O 4 N.C. - 5 GND - 6 Shield -  NOTE: The USB interface is specified for max. 5 m (16,4 ft) cable length.
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 13 of 24 cVEND plug - User manual.docx  4.3. Connector X3 - RS232 V.24 (UART#1) Interface X3 is the connector for a RS232 interface on V.24 level.  Fig. 12: RS232 V.24 (UART#1) Interface at connector X3  Required Connector: The fitting complement for this connector consists of a 4-pole plug Type Molex Micro Fit and the appending Crimp contact.  Manufacturer ordering code Molex 43025-0400 Plug,  4-pole, grid dimension 3.0 mm, Dual Row, Molex Micro Fit housing Molex 43030-0001 Crimp contact, Female, grid dimension 3.0 mm, AWG#20-24, Molex Micro Fit  Table 4: Pin Assignment RS232 V.24 Interface PIN Label Direction Remark 1 Device TXD O  2 Device RXD I  3 Wake-UP I/O see 4.6. Wake-Up 4 GND -
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 14 of 24 cVEND plug - User manual.docx  4.4. Connector X4 - RS232-LVTTL (UART#0) Interface At  connector X4  a  RS232 interface  on  LVTTL  3.3V  level  is  provided.  This  interface offers  also hardware handshake.   Fig. 13: RS232-LVTTL Interface at connector X4  Required Connector: The fitting complement for this connector consists of a 6 -pole plug Type JST PH and the appending Crimp contact.  Manufacturer ordering code: JST PHR-6 - housing, 6-pole, grid dimension 2.0 mm, Single Row JST SPH-002T-P0.5 or SPH-004T-P0.5 Crimp contact  Table 5: Pin Assignment RS232 LVTTL Interface PIN Label Direction  1 Device RTS O  2 GND -  3 Device RXD I  4 Device TXD O  5 Device CTS I  6 Wake-Up I/O see 4.6. Wake-Up  NOTE: The length of the cable to the RS232-LVTTL interface should be kept as short as possible, and must in any case not exceed 3 m.
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 15 of 24 cVEND plug - User manual.docx  4.5. Connector X5 – Power Supply Vcc  cVEND must be supplied by a regulated power supply of 5 V DC only. If switching power supplies are used be sure that there is adequate filtering. Noise from the power supply can result in a reduc-tion of the read/write range of the module. The cable length from the power supply should be as short as possible, and should in any case not exceed 3 m.  Fig. 14: Power Supply at connector X5  Required Connector: The fitting complement for this connector consists of a 2-pole plug Type Molex Micro Fit and the appending Crimp contact.  Manufacturer ordering code Molex 43025-0200 Plug,  2-pole, grid dimension 3.0 mm, Dual Row, Molex Micro Fit housing Molex 43030-0001 Crimp contact, Female, grid dimension 3.0 mm, AWG#20-24, Molex Micro Fit  Table 6: Pin Assignment Power Supply PIN Label Direction Remark 1 Vcc I 5,0 V/DC 2 GND -   NOTE: The reader has to be supplied by a limited power supply (e.g. NEC Class 2/LPS power sup-ply) according IEC EN 60950-1 chapter 2.5, only. Reversing the polarity of the supply voltage may destroy the device. Supply voltages outside the specifications may destroy the device.
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 16 of 24 cVEND plug - User manual.docx  4.6. Wake-Up cVEND offers a standby mode whic can be configured via software commands. If standby is acti-vated the bidirectional Wakeup I/O is used for signaling a wakeup event by the cVEND and can be used by the host to activate the cVEND.   Wakeup by host:  The host controller can awake the cVEND by pulling down the Wakeup line.    Fig. 15:  cVEND internal Wake-up circuit  NOTE:  If the standby - wakeup option is used in connection with the USB interface the USB con-nection will be interrupted while standby mode.
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 17 of 24 cVEND plug - User manual.docx  4.7. Connector X6, X11, X12 - Extension Interfaces Via X11 and X12 the optional extension board, which offers 4 sockets for SAM cards and one socket for a SD memory card, can be connected. Alternatively X11 and X12 can be used to connect custom specific electronics. therefore this con-nectors are offering signals to connect external smart card drivers, SD memory cards, digital I/Os and I2C, SPI and USB Host interfaces. Further technical details, implementation recommendations and schematics are available on request.   NOTICE:  Some of the Extension Interfaces may need a dedicated software driver which may not pro-vided by the standard cVEND SDK. 4.7.1. Connector X6 - RGB Display (cVEND plug flex only) X6 is intended for connecting an external custom specific RGB Display. technical details are avail-able on request.  Fig. 16:  cVEND plug X6 - PIN assignment.
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 18 of 24 cVEND plug - User manual.docx  4.7.2. Connector X11 - SAM and SD Interface   Fig. 17:  cVEND plug X11 - PIN assignment.  4.7.3. Connector X12 - Auxiliary Interfaces  Fig. 18:  cVEND plug X12 - PIN assignment.
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 19 of 24 cVEND plug - User manual.docx  5. Technical Data   flex reader Housing  plug front with contactless symbol (visible dome: PC; plane: Silicon)   Dimensions over all (W x H x D) Dimensions visible  79 x 70 x 37 mm   28.5 mm   Wight   85 g   Temperature Range Operating Storage  -25 °C to +70 °C ambient temperature   -25 °C to +80 °C   Humidity    95 % max, (no condensing)   Power Supply  5,0 to 5,5 V DC (Ripple < 80 mVpp)   Power Consumption Operation  typ. < 1 A, peripherals excluded   Standby Mode  < 20 mA, Full operation after wake-up  1 Sec   Wakeup by Card and digital input   RFID Interface   Integrated Antenna   13,56 MHz   ISO/IEC 14443-A / -B (NFC reader/writer mode) in EMVCo contactless mode   JIS X 6319-4 (Sony Felica) transparent communication channel   NFC IP1 (P2P) and NFC card emulation mode hardware  enabled   Supported Transponder   ISO/IEC 14443-4 compliant smart cards, NFC Type 1, 2 and 4 in card emulation mode, mifare classic, mifare ultralight and fur-ther technologies on request    Peripheral Interfaces   Ethernet - IEEE 802.3/Ethernet, 10/100 Mbps     RS232 (V.24)     RS232-LVTTL, incl. CTS, RTS signals     USB 2.0 Host hardware enabled     USB 2.0 Device    SPI hardware enabled      I2C 100/400 kHz hardware enabled     24-Bit RGB-bus interface for external TFT displays hardware enabled   User Interface  6 LED (4 green, 1 red, 1 yellow), Buzzer,  illuminated Payment Logo   CPU and Security   ARM 9 CPU (384 MHz) – Tamper Protected and Side Channel Attack Resistant with Real Time Memory Encryption   Cryptographic Hardware Acceleration supports  SHA, DES, AES   True Random Number Generator    RAM MByte 128 / FLASH MByte 256    Real Time Clock – Battery backed    Battery   3V Lithium Battery, 540 mAh, Lifetime 10 year at 25 °C1                                                   1 Battery is needed for security function and RTC. Higher temperature will reduced lifetime!
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 20 of 24 cVEND plug - User manual.docx  5.1. Standard Compliance  Radio Approval Europe USA Canada   EN 300 330   FCC 47 CFR Part 15   IC RSS-Gen, RSS-210  EMC   EN 301 489 Safety and Health   EN 60950    EN 50364 Hazardous Substances   RoHS - 2011/65/EC Electrostatic Discharge   ISO 10605, Category 3 Protection Class (Front Side)   IP65 (if accurate installed) Impact protection Class   IEC 62262, IK10 (installed in equivalent robust housing) Shock and Vibration    IEC 60721-3-5, Class 5M3 Payment   EMVCo 2.4 Contactless Level 1   PCI PTS 4.x, SRED incl. Open Protocol  Contactless Payment Kernel (Optional)   MasterCard PayPass   VISA Paywave   American Express Expresspay   Discover    5.2. Radio Approvals 5.2.1. Europe (CE) When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99.    Performance Classification according to ETSI EN 301 489: Class 2
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 21 of 24 cVEND plug - User manual.docx  5.2.2. USA (FCC) and Canada (IC)  Product name: cVEND plug FCC ID: IC: PJMcVEND 6633A-cVEND Notice for USA and Canada   This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions.  (1) this device may not cause harmful interference, and  (2) this device must accept any interference received,  including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Le présent appareil est conforme aux CNR d'Industrie Canada appli-cables aux appareils radio exempts de licence. L'exploitation est auto-risée aux deux conditions suivantes :  (1) l'appareil ne doit pas produire de brouillage, et  (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonc-tionnement.  Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.   Installation with FCC / IC Approval: FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-ards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to en-sure that only certified systems are deployed in the United States / Canada.
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 22 of 24 cVEND plug - User manual.docx
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 23 of 24 cVEND plug - User manual.docx  6. cVEND plug SAM Extension - Option The optional SAM Extension board offers 4 sockets for ID000 Format smart cards and one SDHC memory card socket. It can be connected to cVEND plug via connector X11 and X12.     Fig. 19:  cVEND plug SAM Extension - top view    Fig. 20:  cVEND plug SAM Extension - bottom view  SAM1 SAM2 SAM3 SAM4 µSD µSD X20
 Installation cVEND plug  FEIG ELECTRONIC GmbH Page 24 of 24 cVEND plug - User manual.docx  X20: Auxiliary Interfaces Via the 20 pol. FFC/FCP, RM 0,6 connector X20 the SPI, RS232-LVTTL, USB-Host and I2C interfaces as well as digital GPIOs are provided.   NOTICE:  Some interfaces may need a dedicated software driver which may not provided by the standard cVEND SDK.     Fig. 21:  cVEND plug SAM Extension - X20 Pin assignment    Removal Memory microSD Socket SD Host Controller Version 2.0 for SD/SDHC class 10 memory card SAM Interface - ISO7816  4 x SAM Sockets for ID000 Format (SIM-Card) T=0 and T=1 Protocol  support of power class A, B, C