Exalt Wireless 105P25T Radio Module 5GHz User Manual revised manual

Exalt Communications Inc. Radio Module 5GHz revised manual

Contents

revised manual

203591-0112013-02-22ExtendAir® (TDD) SeriesDigital Microwave RadiosInstallation and Management GuideModels:r40xx & rc40xx Seriesr49xx & rc49xx Seriesr50xx & rc50xx Series
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radiosii 203591-0112013-02-22Legal NoticeThe information contained herein is the property of Exalt Communications, Inc. (“Exalt”) and is supplied without liability for errors or omissions. No part of this document may be reproduced, in any form, except as authorized by contract or other written permission from the owner.Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders.The contents of this document are current as of the date of publication. Exalt reserves the right to change the contents without prior notice.The publication of information in this document does not imply freedom from patent or other rights of Exalt or others.© 2013 Exalt Communications Inc. All rights reserved. The Exalt logo is a trademark of Exalt Communications, Inc. ExtendAir is a registered trademark of Exalt Communications Inc.Open-Source License InformationPer the terms of your Exalt Limited Hardware Warranty, Software License, and RMA Procedures Agreement with Exalt Communications, Inc. and/or its subsidiaries, certain Third Party Software may be provided with and as part of the Exalt products provided to you, and any such Third Party Software files provided are governed by the terms of their separate Third Party Licenses, which licenses give you at least the license rights licensed to you in the Exalt End User Agreement and may give you additional license rights as to the Third Party Software, but only with respect to the particular Third Party Software to which the Third Party License applies.The Exalt Products may include or be bundled with some or all of the following third party software. Copies of the copyright notices and license agreements for any or all of these may be requested by contacting Exalt support at email: support@exaltcom.com. Open Source Code License Agreement WebsiteEmbedded Linux - OS U-Boot  Boot Code.  Both licensed under GPL Version 3  www.gnu.org www.sourceforge.netBusy Box  Linux Commands.  Licensed under GPL Version 2  www.gnu.org and www.busybox.netScew  Expat Wrapper.  Licensed under LGPL Version 3  www.gnu.orgOpenSSL  SSL Web Access.  Licensed under dual license  www.openssl.org Net-SNMP  SNMP Agent.  Licensed under NetSNMP (see Copyright Notices)Dropbear   SSH 2 Server; Expat - XML Parser; BarelyFitz – Java Script Tabifier; jQuery; and Flotr – Java Script Plotting Library. All of which are licensed under MIT Licensewww.opensource.org/licenses/mit-license.phpGoAhead Webserver Licensed under GoAhead License Agreement  www.goahead.com
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 iii2013-02-22Table of ContentsLegal Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iiOpen-Source License Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iiList of Figures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  viList of Tables  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  viiiNotes for Customers of the Cisco Configuration ExtendAir r5005 . . . . . . . . . . . . . . . . . . . .  ixAbout this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xRevision History   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xIcons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xIntroduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Related Documentation and Software    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1The ExtendAir (TDD) Series Digital Microwave Radios    . . . . . . . . . . . . . . . . . . . . . . . . 1Basic Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Pre-installation Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Link Engineering and Site Planning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Familiarization with the ExtendAir (TDD) Series Radios . . . . . . . . . . . . . . . . . . . . . . . . . 6Initial Configuration and Back-to-Back Bench Test  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Time Division Duplex (TDD) Factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Link Orientation and Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Radio Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Offset Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Virtual Local Area Network (VLAN)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Simple Network Management Protocol (SNMP)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17System Installation and Initiation Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Record Keeping  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Mechanical Configuration and Mounting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Radio Ports and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Power  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CAT5e Lightning/Surge Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Reset to Critical Factory Settings   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Antenna/Transmission System   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Transmission Line from Antenna to Radio (rc models)   . . . . . . . . . . . . . . . . . . . . . . . . . 28Antenna Alignment  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Configuration and Management   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Telnet into the Command Line Interface (CLI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Telnet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Exalt Graphical User Interface (GUI)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Quick Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Navigating the GUI  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Radio Information Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Administration Settings Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40NTP and Time Zones Configurations Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Simple Network Management Protocol (SNMP) Configuration . . . . . . . . . . . . . . . . . . . 43File Management Pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46File Transfer Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46File Activation Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radiosiv 203591-0112013-02-22System Configuration Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Ethernet Interface Configuration Page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55T1/E1 Configuration Pages  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57VLAN Configuration Page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Ethernet Rate Limiting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62QoS Configuration Page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Automatic Channel Selection (ACS) Page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Syslog Configuration Page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70GPS Information Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Alarms Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Performance Page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Event Log Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76User Throughput Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77Diagnostic Charts Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Spectrum Analyzer Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81Ethernet Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Reboot Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Manual Page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Physical Specifications   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87System Specifications, 4.9GHz Band  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89System Specifications, 4.9GHz Band  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90System Specifications, 5.3GHz Band  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91System Specifications, 5.4GHz Band  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92System Specifications, 5.8GHz Band  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Interfaces  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Interface Connections   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95TDM Connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95RSL/Sync Connector  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Power/Ethernet Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Antennas   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102General Practices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102Typical Indications of Issues  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103Improper RF Cable Termination  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104Multipath Propagation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104RF Interference   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104Path Obstruction   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105Misaligned Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105Faulty Antenna (connectorized antenna rc-models only)  . . . . . . . . . . . . . . . . . . . . . . . 105Improper Grounding   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105Insufficient Link Margin  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Moisture in the Transmission System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Back-to-back Bench Testing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107Basic Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107Specification Performance Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108General Compliance and Safety   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 v2013-02-22Dynamic Frequency Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110Safety Notices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Regulatory Notices   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11349xx Models   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113United States Compliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113Canada Compliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114Europe and ITU Country Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115Regulatory Compliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116EIRP Limits for the United States and Canada  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118EIRP for the USA and Canada   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118EIRP Limits for Australia  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119EIRP Limits for the European Union and ITU Countries  . . . . . . . . . . . . . . . . . . . . . . . . . . 12050xx Series EIRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120Declaration of Conformity to the R&TTE Directive1999/5/EC   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123EU WEEE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123EU RoHS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124Exalt Limited Hardware Warranty Software License and RMA Procedures Agreement  . . 125Copyright Notices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130Index   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radiosvi 203591-0112013-02-22List of FiguresFigure 1 Exalt ExtendAir (TDD) r5000 (integrated antenna model)    . . . . . . . . . . . . . . . . . . . . . . . 1Figure 2 Mounting and cabling—integrated antenna model  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Figure 3 Cabling and mounting—external antenna model   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Figure 4 Synchronized GPS sources   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Figure 5 Internal Sync for two collocated radios  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Figure 6 Internal Sync for more than two collocated radios   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Figure 7 GPS Sync for more than one collocated radios  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Figure 8 Synchronization for radios in a chain   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Figure 9 Radio installation tasks   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Figure 10 Pole-mount example (integrated antenna version) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Figure 11 ExtendAir (TDD) Series connectors (model r5000)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Figure 12 Power injector connectors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Figure 13 CLI main menu   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Figure 14 Initiating the browser connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Figure 15 Browser Login screen   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Figure 16 Radio Information page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Figure 17 Exalt GUI window description   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Figure 18 Summary status information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Figure 19 Radio Information page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Figure 20 Administration Settings page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Figure 21 NTP and Time Zones Configurations page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Figure 22 SNMP Configuration page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Figure 23 Trap Configuration page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Figure 24 File Transfer page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Figure 25 File Transfer page—download file link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Figure 26 File Activation page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Figure 27 System Configuration page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Figure 28 Ethernet Interface Configuration page (multiple Ethernet ports model)  . . . . . . . . . . . . . 55Figure 29 T1 Interface Configuration page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Figure 30 E1 Interface Configuration page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Figure 31 External (remote) loopback  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Figure 32 External (local) loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Figure 33 Internal loopback  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Figure 34 VLAN Configuration page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Figure 35 Ethernet Rate Limiting page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62Figure 36 QoS Configuration page (multiple Ethernet interface model) . . . . . . . . . . . . . . . . . . . . . 63Figure 37 MAC DA based QoS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64Figure 38 VLAN ID based QoS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Figure 39 802.1p based QoS mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Figure 40 IPv4/IPv6 based QoS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Figure 41 Port based QoS mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Figure 42 Automatic Channel Selection page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Figure 43 Syslog Configuration page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70Figure 44 GPS Information page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Figure 45 Alarms page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Figure 46 Performance page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Figure 47 Event Log page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76Figure 48 User Throughput page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77Figure 49 Aggregate User Throughput Help page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 vii2013-02-22Figure 50 Diagnostic Charts page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Figure 51 Spectrum Analyzer page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81Figure 52 Spectrum analyzer graph example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Figure 53 Ethernet Utilization page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Figure 54 Reboot page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Figure 55 Manual page   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Figure 56 TDM connectors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Figure 57 RSL & Sync In/Sync Out connector  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Figure 58 Power/Ethernet connector  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Figure 59 Basic back-to-back bench test configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radiosviii 203591-0112013-02-22List of TablesTable 1 Factory default settings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Table 2 Connectors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Table 3 LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Table 4 Recommended transmission line  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Table 5 Default login information   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Table 6 Alarm status indicators   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Table 7 5GHz Antennas  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98Table 8 Product Approvals (Exalt)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Table 9 EU and ITU Country Specific EIRP Levels   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radiosix 203591-0112013-02-22Notes for Customers of the Cisco Configuration ExtendAir r5005Customers who purchased the Cisco configuration of the ExtendAir r5005 should note the following:•The Cisco configuration ExtendAir r5005 has an integrated antenna. Sections of the manual that refer to the rc5005 or any rc models (those with connectors for external antennas) are not relevant.•The Cisco configuration ExtendAir r5005 is not available in the 5000, 5010, or 5015 variants nor any 49xx variants. The specifications, connections, and capabilities listed for those models are not applicable.• Cisco configuration radios provide specific the following capabilities for regional regulatory domain compliance, as ordered:– Certain frequency bands and/or tuning ranges are available and/or blocked from use– EIRP (maximum output power) limits may be applied– Channel bandwidth (size) selections may be limited and/or named in accordance with regulations– Dynamic Frequency Selection (DFS) may be enforced and not selectable, per regulations•The Cisco configuration ExtendAir r5005 is provided standard with full Ethernet capacity and 128-bit AES encryption. No license keys are required for capacity, and only 256-bit AES encryption is available as an upgrade license key.•The Cisco configuration ExtendAir r5005 is packaged with the integrated AC power injector (not sold separately). The DC power injector is not provided. Information regarding DC power is not applicable.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radiosx203591-0112013-02-22About this DocumentThis manual provides a complete description of the ExtendAir (TDD) Series Digital Microwave Radios and related software. This manual provides planners, engineers, installers, system administrators, and technicians general and specific information related to the planning, installation, operation, management, and maintenance of these devices.Revision HistoryIconsThe following icons denote specific types of information:Date Products and Release code2009-11-16 Models 5000, 5005, 5010, and 5015 initial release v1.0.0 through v1.1.32009-12-18 Models 4900, 4905 and 4910 initial release v1.02010-09-20 Update for Cisco-configuration r5005 release and Internal Sync release, v1.4.02010-12-21 Update to regulatory information, v1.4.32011-06-06 Update VLAN configuration from previous releases and add 40xx Series Models. Manual reflects v1.4.5 for 50xx models; v1.0 for 40xx and 49xx models.2011-07-16 Update for software release 1.5.0 for 50xx models; includes QoS configuration feature.2011-12-14 Update for software release 1.6.0 for 50xx models; includes ACS and port-to-port Ethernet mode selection features.2012-04-10 Added NTP and SysLog features.2012-09-14 Updated for DFS regulation changes.2013-02-22 Updated for FCC release of U-NII bands (DFS).Note:  This symbol means take note. Notes contain helpful suggestions or references to materials not contained in the manual.Warning!   This warning symbol means there is a risk of electric shock. This situation that could cause bodily injury. Before working on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.Caution!   This symbol means be careful. There is a risk of doing something that might result in equipment damage or loss of data. This is a general warning, caution, or risk of danger.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 12013-02-22Introduction Exalt Communications, Inc. thanks you for your purchase. Our goal is to build the highest quality, highest reliability digital microwave radio products. This commitment to quality and reliability extends to our employees and partners alike. We appreciate any comments on how we can improve our products, as well as your sales and Customer Care experience.  Related Documentation and Software This manual makes reference to other documentation and software files that may be necessary. To access all documents and software mentioned in this manual visit: http://login.exaltcom.com/ You must have a user account to view all downloads. Follow the online instructions to create a user account and request access. The ExtendAir (TDD) Series Digital Microwave Radios The Exalt ExtendAir (TDD) Series Digital Microwave Radios are the most advanced carrier-class point-to-point terrestrial radio communications devices operating in the 4400 to 4900,   4940 to 4990, or 5250 to 5875 MHz bands. The ExtendAir (TDD) Series radios are available in the following configurations: •r-models have an integrated antenna. • rc-models have a connector for external antenna connection The ExtendAir (TDD) Series radios connect voice and/or digital data from one location to another, obviating the need for copper or fiber connectivity, or enhancing existing connectivity by providing a redundancy solution, a primary solution, and/or additional capacity. Figure 1 shows the ExtendAir (TDD) Series r5000 digital microwave radio. Figure 1   Exalt ExtendAir (TDD) r5000 (integrated antenna model) Customer Care Hotline (USA): (408) 688-0202 Toll-Free Customer Care Hotline (USA): (877) EXALT-01 (392-5801) Direct-Dial Telephone (USA): (408) 688-0200 Website: www.exaltcom.comSales e-mail: sales@exaltcom.comCustomer Care e-mail: support@exaltcom.comMailing Address: Exalt Communications, Inc.254 E. Hacienda Ave.Campbell, CA 95008USA
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios2203591-0112013-02-22The following ExtendAir (TTD) models are covered in this manual: •r4005 and rc4005– configured with 27Mbps aggregate Ethernet capacity (1PoE port plus two additional Ethernet ports)– with license key upgrades for 55 and 160Mbps aggregate capacity•r4010 and rc4010– configured with 27Mbps aggregate capacity and 4xT1/E1 (single PoE port)– with license key upgrades for 55 and 160Mbps aggregate capacity• r4900 and rc4900 – configured with 27Mbps aggregate Ethernet capacity (single PoE port) – with license key upgrades for 55, 80, and 162Mbps aggregate capacity • r4905 and rc4905–  configured with 27Mbps aggregate Ethernet capacity (1 PoE port plus 2 additional Ethernet ports) – with license key upgrades for 55, 80, and 162Mbps aggregate capacity • r4910 and rc4910 – configured with 27Mbps aggregate capacity and 4xT1/E1 (single PoE port) – with license key upgrades for 55, 80, and 162Mbps aggregate capacity • r5000 and rc5000 – configured with 27Mbps aggregate Ethernet capacity (single PoE port) – with license key upgrades for 55 and 162Mbps aggregate capacity • r5005 and rc5005 – configured with 27Mbps aggregate Ethernet capacity (1 PoE port + 2 additional Ethernet ports) – with license key upgrades for 55 and 162Mbps aggregate capacity • r5010 and rc5010 – configured with 27Mbps aggregate capacity and 4xT1/E1 (single PoE port) – with license key upgrades for 55 and 162Mbps aggregate capacity • r5015 and rc5015 – configured with 2Mbps aggregate Ethernet capacity and 2xT1/E1 (single PoE port) – with license key upgrades for 27, 55, and 162Mbps aggregate capacity with license key upgrade for 4xT1/E1 Note: All models offer license key upgrades for 128- or 256-bit AES encryption.Note: The Cisco configuration r5005 is pre-configured to allow full capacity (162Mbps aggregate) and 128-bit AES wireless encryption.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 32013-02-22The ExtendAir (TDD) Series radios require a clear line-of-sight and proper path clearance to achieve a high-performance, reliable connection. Perform professional path engineering and site planning before installing this equipment. The primary focus of this document is the installation and maintenance of the digital microwave radio, and assumes that path engineering and site planning has already been performed. The 50xx family ExtendAir (TDD) Series radios utilize radio frequencies in the 5250 to 5875 MHz range. In most countries these frequency bands are considered as ‘license-exempt’ or ‘unlicensed.’ This means that virtually any user may use these frequencies freely, without paying for access, or any type of prenotification, post-notification or registration. As a result of this designation, users may also move or change these systems at any time, with significant flexibility to the location, orientation and configuration of the system. However, due also to this designation, there may be uncontrolled interference from other similar devices that occupy this spectrum. In these cases, it is up to engineering and maintenance personnel to design the system with existing and future interference sources in mind, recognizing that there is a chance that the interference conditions could be very dynamic, and outages may occur on the system as a result, and that, in some very rare cases, the system may cause interference into another system and may be required to be disengaged or modified/re-oriented to eliminate the interference. If the spectrum in your country is designated as ‘license-exempt’ or similar, this does not infer that the installer may configure the system in any manner at any location. In most cases, there are regulations, or device-based conditions that limit the use of the device, such as maximum gain antenna, antenna types and maximum output power, as well as, in some cases, application limits, limited geography of use, and other unique regulations. The link design engineer and/or professional installer must determine these limitations and engineer/install the system within the confines of all local regulations. Also, it is required to examine any regulations that may apply to peripheral equipment, installation and cabling of the system that may be regulated for human safety, electrical code, air-traffic control, and other safety-related categories. In certain countries, the spectrum for this product is NOT considered to be license-exempt. In these cases, there may be additional regulatory requirements concerning the location, frequency, power, orientation, configuration, and other aspects of the system, including, in some cases, a need for link registration, coordination, and fees that may apply to the system usage. Please consult your local regulatory organization(s) to determine usage requirements. The 49xx family ExtendAir (TDD) Series radios utilize frequencies in the 4940–4990MHz range, which is typically a licensed band reserved for use by Public Safety agencies and applications. The 40xx family ExtendAir (TDD) Series radios utilize frequencies in the 4400–4900 MHz range, which are typically reserved for Government users.In almost all cases, either for license-exempt or other designation, the product itself must be authorized for use in your country. Either Exalt or Exalt’s agent must have applied for certification or authorization to allow the sale and deployment of the system within the country. It is also possible that only certain versions or configurations of the device are allowed within a particular country. Please contact Exalt or your authorized Exalt representative for information pertaining to your country. Note: It is the (professional) installer’s responsibility to ensure that the radio system is implemented in a legal fashion. Exalt is not liable for any unsafe or illegal installations.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios4203591-0112013-02-22Basic Features The ExtendAir (TDD) Series Digital Microwave Radios are intended for all-outdoor mounting and come with an indoor-mounted power injector. In some cases, the radio can be mounted indoors or in an enclosure. Depending on the configuration purchased, the associated antenna is either integrated as part of the unit or connected separately. For the integrated antenna models, the entire unit is typically mounted on a tower or rooftop mast structure, with Ethernet/Power and other optional interface cables running from the unit location, through a structure penetration, and to the power injector and connected communications equipment. For the external antenna models, the unit is typically mounted very close to the external antenna to minimize RF cabling and associated losses. Alternatively, the unit can be mounted at an easily accessible location with longer RF cabling to the antenna. Proper lightning or surge suppression devices and associated grounding are required for all connections. Figure 2   Mounting and cabling—integrated antenna model
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 52013-02-22Figure 3   Cabling and mounting—external antenna model For highest performance and reliability, it is advised to minimize the length of RF cable and associated transmission system losses between the antenna and the radio’s antenna port. The ExtendAir (TDD) Series radios provide connections for a combination of the following data communication interfaces: •10/100BaseT Ethernet (up to 3 ports, depending on model) •Up to 4xT1/E1 interfaces for synchronous voice traffic (xx10 and xx15 models only) The ExtendAir (TDD) Series radios are powered by a combined Power/Ethernet cable, and associated power injector. The power injector provides 48VDC to the unit. The power injector and/or external power supply are sold separately. The ExtendAir (TDD) Series radios provide the following primary features and benefits: •Low-latency optimization and control for voice and data connections •Very high throughput and flexible interface configurations with voice+data combinations •Encryption for extreme wireless security •Easy-to-use management and configuration •Flexible utilized channel bandwidth selection for interference avoidance and frequency coordination •Flexible center frequency tuning for interference avoidance and frequency coordination •Flexible capacity to meet current connection requirements and future growth needs •Carrier-class reliability and performance •Connector covers (for weatherproofing unused connectors)
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios6203591-0112013-02-22Pre-installation TasksThis section describes the steps necessary to prepare a site for the installation of the Exalt Digital Microwave Radio.Link Engineering and Site PlanningDesign all terrestrial wireless links prior to purchase and installation. Generally, professional wireless engineering personnel are engaged to determine the viability and requirements for a well-engineered link to meet the users’ needs for performance and reliability.Please use the ExaltCalc path calculator, which aids in the pre-planning and engineering required to determine following attributes:•Antenna type gain at each end of the link•Antenna mounting height/location for proper path clearance•Antenna polarization orientation•RF cabling type, length, connectors, route, and mounting•Antenna system grounding•Lightning arrestor type(s), location(s), and grounding•Radio mounting location and mechanisms•Radio grounding•Radio transmitter output power setting•Anticipated received signal level (RSL) at each end•Anticipated fade margin and availability performance at each end•Radio settings for TDD frame length and occupied bandwidth•Anticipated throughput performance (TDM circuit support and Ethernet)•Anticipated system latencyWith respect to radio path and site planning, these radios are generally identical to other microwave terrestrial wireless systems. Engineering of these systems requires specific knowledge about the radios, including:•RF specifications (transmitter output power, receiver threshold, occupied channel bandwidth, and carrier-to-interference)•Regulatory limitations on transmitter output power setting and antenna type/gain•Noise/interference profile for the intended locationFamiliarization with the ExtendAir (TDD) Series RadiosThe ExtendAir (TDD) Series radios utilize time division duplex (TDD) radio transmission. This means that the transmitted signal in both directions uses the same center frequency and transmits in one direction for a period of time, and then in the opposite direction for another period of time. This total period of time is referred to as the frame length or TDD frame length, and is further discussed in Time Division Duplex (TDD) Factors.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 72013-02-22The two radio terminals are identical hardware, except for the TDD setting in software. When the radios are in their default state, both radios are configured as Radio B. One end of the link must be configured as Radio A before the two ends of the radio system can communicate. It can be considered that Radio A is the primary radio in the link. Radio A provides the master clock and control to Radio B. For most applications, it is not important how the radio link is oriented, only that one end is configured for Radio A and the other for Radio B. For some applications (such as, multi-radio hub sites or repeaters), the orientation of the radio systems may be more critical. See Link Orientation and Synchronization for details.There are two ways to configure the radios for Radio A/B determination:•Use the Exalt browser-based graphical user interface (GUI) – preferred.•Connect to the radio using Telnet.Exalt recommends using the Exalt GUI for radio configuration. This interface requires a computer with an Ethernet port and web browser software, such as Microsoft Internet Explorer 5.0 or above. See Configuration and Management for details on how to connect to and use the browser-based GUI interface.Shipping Box ContentsUnless purchased as a spare terminal, the radios are shipped as a complete hop (that is, a radio link pair consisting of two terminals). An outer box has labeling that indicates the contents of the box, with the part number and serial number details for both radio terminals.Inside the outer box are two identical boxes, each of these boxes is also marked with the part number and serial number of the individual terminal contained inside the box. The terminal box contains the following items:•Radio terminal (configured as Radio B)•Mounting kit (for pole or wall mounting)•Accessory kit– Grounding screw/washers– Weather-sealing tape (required for RF connectors on the rc versions)– RSL adapter cable•Registration card•Quick-start guideThe power solution for ExtendAir is sold separately. For customers requiring direct 48V DC power, a power injector is available. For AC-powered applications, a POE/Adapter combination is available.Inspect the outer packaging and the contents of the boxes upon receipt. If you suspect any shipping damage or issues with the contents, contact Exalt Customer Care.Outdoor-rated and shielded CAT5e cable, such as Beldon 1300A, with RJ-45 or RJ-48C connectors is recommended for the Ethernet and/or TDM connections. For Ethernet connections, a maximum length Note: Register your system as soon as possible. A 2-year Warranty period applies to products registered within 90 days of purchase. The Warranty period is reduced to 1-year for unregistered products and products registered after the first 90 days.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios8203591-0112013-02-22of 100 meters applies to the total length of the cabling between the radio terminal and the first network-aware connection (such as a switch or router).Initial Configuration and Back-to-Back Bench Test Every Exalt digital microwave radio goes through extensive quality testing and performance evaluation over the full operating temperature range prior to shipment. However, before installation, it is strongly advised to perform several tests and tasks that are much more difficult to perform once the radio link endpoints are distant from one another. A back-to-back bench test and pre-configuration will provide confidence that the radio link is operational and properly configured prior to installation, so that if troubleshooting is necessary, the radio hardware and configuration settings are eliminated from the troubleshooting process. Verify the following in the back-to-back testing:•Confirm that the radio system is generally operational– Radios power-up with planned power and wiring solutions– Radio firmware version matches on each terminal (and is ideally the latest version)– Upgrade license key entry successful– RF link connects in both directions– Traffic passes across the link– Configure connected equipment and cabling– Test Ethernet (CAT5e) cabling, and/or T1/E1 cabling, any auxiliary connector cabling and configure all interfaces– Configure IP settings for configuration and management– Configure passwords and security modes– Become familiar with the configuration and management interfaces through the Exalt GUI interface– Configure radio parameters– Set transmitter output power to engineered or allowed level (see RF Output Power Setting)– Set operating center frequency– Set link distance, occupied channel bandwidth, and frame length•Make detailed radio performance measurements– Measure transmitter output power– Measure receiver threshold performance– Confirm unfaded error-free performanceSome of these tasks may not be possible or practical within a bench test environment due to the nature of the remote connectivity of peripheral equipment. However, it is good practice to perform as much as possible in this environment to minimize field/installation time and troubleshooting efforts.Note: Some countries require Dynamic Frequency Selection (DFS), which delays the transmitter turn-on time during the initial Channel Availability Check period of 1 minute. In accordance with these regulations, the radios boot up, and then wait for 1 minute before linking.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 92013-02-22Detailed performance measurements are usually not required for pre-installation, but can be easily performed at this stage and may be helpful for later troubleshooting efforts or for internal records. During troubleshooting, there may often be a point at which a back-to-back bench test should be performed to verify many or all of the above items, and in the case of a suspected faulty device, to help confirm the fault and determine which end of the system is at fault and in need of repair or replacement.RF Output Power SettingThe maximum RF output power is bounded by one of the following criteria:•Maximum RF output power setting capability of the radio device, including any software limits that are applied to the use of integrated or external antennas, based on regulatory limits•Maximum RF output power allowed/authorized by the local government regulations and for this specific device•Maximum effective isotropic radiated power (EIRP) of the transmission system allowed/authorized by the local government regulations and for this specific device•Desired RSL to not exceed the maximum RSL allowed by the device•Desired RSL to minimize/eliminate interference into neighboring systemsTime Division Duplex (TDD) FactorsThe ExtendAir (TDD) Series radios are very dynamic, allowing the installer to optimize and control the performance of the radio system for the intended application. The following parameters must be carefully determined during the link engineering phase:•Link distance•Bandwidth•TDD frame size•Mode (modulation)•The setting of the above parameters determines the following performance factors:•Number of supported T1/E1 channels (on applicable models)•Ethernet throughput•System latency (delay)Use the ExaltCalc calculator to determine optimum settings for the above parameters to meet the needs of your application.The following generalizations can be made with regards to these factors:•The shorter the TDD frame size, the lower the latencyNote: See Back-to-back Bench Testing for detailed instructions.Note: In many cases the radio must be pre-configured for legal maximum output power before connecting to the antenna and transmission system. Instructions for adjusting the output power can also be found at the rear of this guide in the EIRP section for your region.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios10 203591-0112013-02-22•The shorter the link distance, the lower the latency, the higher the throughput•The longer the TDD frame size, the higher the throughput•The higher the bandwidth, the higher the capacity•The higher the mode, the higher the capacityLink Orientation and SynchronizationLink orientation refers to the Radio A and Radio B placement in your network. Link synchronization refers to using external or internal timing to coordinate multiple links.For every link, one end of the radio link must be configured as Radio A, while the other end is configured as Radio B. In single-link systems, it does not matter which end of the system is mounted at which end of the link, and there is typically no requirement for any link synchronization.Link orientation and synchronization are more important for networks with site(s) where there is more than one link of the same type or for sites using the same type of radio that are very close to each another at one or both ends. Configure collocated radio terminals for the same link orientation. That is, configure all radios at the same location as Radio A or Radio B. It can be advantageous to utilize link synchronization for collocated links. The radios allow the use of an optional GPS synchronization kit. This synchronization controls the transmitter and receiver frame timing so that collocated radios are transmitting at the same time and receiving at the same time. This can substantially reduce the opportunity for self-interference. Without synchronization, collocated radios may be transmitting and receiving at the same time, incurring near-end interference. When synchronization is required or desired, the following configurations are recommended:•For a two-radio network without GPS, use Internal Sync and connect a single cable between the SYNC/RSL ports on both radios (see RSL/Sync Connector for wiring instructions). •For a two-radio network using GPS sync, use two GPS kits or one GPS kit and the ExaltSync Collocation kit.Note: Disable all T1/E1 ports if there are no T1/E1 interfaces connected. This shifts all available throughput to the Ethernet interface.Note: If a selected combination of the Link Distance, Frame Size, Bandwidth, and Mode parameters cannot support all the desired T1 or E1 ports, the ports that cannot be supported are automatically disabled. Priority is placed on the T1/E1 port number. That is, the first port to be disabled, if necessary, is the highest port number, such as Port 4. See T1/E1 Configuration Pages for more information.Note: It is not always necessary to synchronize collocated radios. If antennas are substantially separated or blocked from one another and/or frequency separation tuning is used, the opportunity for near-end interference can be eliminated.Note: Refer to the ExaltSync Collocation Expansion Kit Quick Start Guide for instructions.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 112013-02-22•For a network of two or more radios using Internal Sync, connect using the ExaltSync Collocation kit.•For a network of two or more radios using GPS Sync, connect using one GPS kit and the ExaltSync Collocation kit, or connect using one GPS kit per link.Radio A/B ConfigurationUse the Exalt GUI to configure the radio terminals for Radio A and Radio B orientation. Since many other parameters also need to be set, and the Exalt GUI is needed for these configurations, this is the best way to completely configure the radio terminals.Radios arrive from manufacture in default configuration, orientated as Radio B and configured as shown in Table 1.Table 1  Factory default settingsParameter ExtendAir (TDD) Series Radio SettingsFrequency 5GHz models: 5788 MHz (5600 or 5785 MHz if the regulatory domain does not allow 5788 MHz)4.9GHz models: 4965 MHzTransmit Power +4dBmLink Distance <10 milesBandwidth 8 MHz (10 MHz for some regulatory domains)Mode Mode 1TDD Frame Size 2msLink Security Key 000000000000Administration Password passwordUser Password passwordIP Address 10.0.0.1IP Mask 255.0.0.0IP Gateway 0.0.0.0Ethernet Interface Alarm Enabled, 100/FullT1/E1 Enabling All Disabled
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios12 203591-0112013-02-22Radio ResetUse the reset function if the IP address and/or passwords are lost. Use the following steps to perform a critical parameter reset:1Remove power from the radio by disconnecting the AC adapter from the power injector.2Hold down RESET button on the power injector while applying power. Hold the RESET button down through the entire power cycle and monitor the DATA+POWER left LED on the power injector. Release the RESET button only after the LED is in the steady state (45 to 60 seconds).3Release the RESET button.The following configurations are reset on the radio:•IP address = 10.0.0.1•IP mask = 255.0.0.0•IP gateway = 0.0.0.0•Administration password = password•User password = password •VLAN disabledRadio SynchronizationThe radio synchronization feature improves the performance of Exalt radios operating in the same frequency band and that are collocated (such as in repeater and hub configurations). Radio synchronization ties radio systems together to operate off of a common clock system, ensuring that all radios simultaneously transmit and receive, and thus eliminating near-field interference issues and related radio system coupling.Synchronization ModesSynchronization can be implemented using either one or multiple GPS sources, or using the radios 'Internal' clocking signal. The following general configurations can be accommodated:•GPS sync, using one GPS source (sold separately) per link. Ideal for links where the radios are not collocated on the same rooftop or tower. •GPS sync, using one GPS source (sold separately) to drive timing to multiple collocated links, using one or more sync distribution accessories (sold separately). The ideal solution for networks that have multiple links at one location, but also have more nearby radio links that are not collocated, including repeaters and multi-link backbones.•Internal sync, using one radio to synchronize another collocated link. This can be accomplished with a simple cable and proper radio configuration, and ideal when only 2 radios are collocated.Note: In many cases, the system design will not be identical to the factory default configuration, and in some cases, these differences prohibit the installation of the radio. If at all possible, obtain a computer and configure the radio terminals using the browser-based GUI. See Exalt Graphical User Interface (GUI) for details.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 132013-02-22•Internal sync, using one radio to synchronize to multiple collocated links. This can be accomplished with one or more sync distribution accessories (sold separately). The ideal solution for networks that have multiple links at one location and do not have other nearby links or repeaters and multi-link backbones.Virtually any combination of hubs and repeater sites, star configurations, and/or backbones can be implemented with synchronization. It is typically necessary or ideal in each configuration to match the following parameters on every radio in the network:•Link Distance – Match to the longest distance link in the network.•Frame Length – Match to the lowest frame length to optimize total system latency (for example, for TDM networks) or match to a highest frame length to optimize user throughput. Choose an intermediate value to compromise between latency and throughput.•Mode – It is desirable, but not always necessary, to match the mode for all collocated links.•Bandwidth – It is desirable, but not always necessary, to match the bandwidth for all collocated links.For complex networks, an Exalt engineer should review multi-link networks before deployment as several factors can optimize the network for desired performance.Figure 4 illustrates two separate radios benefiting from synchronized GPS sources.Figure 4   Synchronized GPS sourcesFigure 5 illustrates the recommended synchronization method for two links that share a common site at one end of each link. Using internal sync, a cable can be connected between the two radios to accomplish sync. No GPS receiver is required. This approach cannot be used for more than two collocated radios.Note: When GPS Sync is enabled, link initiation typically takes 1 to 3 minutes to allow for the radio to properly synchronize to the available GPS satellites.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios14 203591-0112013-02-22Figure 5   Internal Sync for two collocated radiosWhen more than two radio links terminate from the same site, use the sync distribution accessory, ExaltSync Collocation Kit (sold separately) to connect more links to the Internal Sync source, as shown in Figure 6. Use one kit to connect one Sync Source radio to up to three additional links. Each additional kit expands up to three additional links.Figure 6   Internal Sync for more than two collocated radiosThis approach can also be used using an Exalt GPS source for synchronization, instead of Internal Sync, as shown in Figure 7. This approach is recommended if there are other nearby sites that are not collocated or part of the connected network that need to be synchronized. Using one kit, a single GPS Antenna can synchronize up to 4 collocated links. This can be expanded 3 additional links per additional kit.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 152013-02-22Figure 7   GPS Sync for more than one collocated radiosAt the far end of a synchronized link, if there are additional links to synchronize, use the Sync Out port of the Radio B to drive synchronization to the collocated radios. If there is only one additional radio, connect a cable from Sync Out to the Sync In port of the next radio, which should be configured as Radio A. Set this radio in the chain to Sync Recipient, as shown in Figure 8. If more than one radio is located at the secondary location, to drive synchronization for multiple Radio A terminals connect a ExaltSync Collocation Kit driven from the Radio B Sync Out port.Figure 8   Synchronization for radios in a chainOffset TimingFor GPS implementations, manual control of offset timing is also allowed. This provides a means to delay the synchronization signal using a user-defined offset. This is helpful when Exalt radios are near other devices operating in the same frequency band that also use a timing source, such as GPS. The timing source to the Exalt radios can be adjusted to match the other radio system timing source mechanism.Offset timing can also optimize timing intervals for repeaters and backbones. As the distance of each link results in a unique factor for speed-of-light transmission of the radio signal, a subsequent radio can be delayed in timing so that the overall synchronization of radios is precisely maintained.Offset timing can be adjusted in 1-ms intervals, from zero to the radio’s frame length setting. For example, if using a 2-ms frame length, the offset timing can be set from zero up to 1999 ms.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios16 203591-0112013-02-22When Sync is LostIf the primary sync source (for example, the GPS source) signal is lost due to equipment failure, a disconnected sync cable, loss of satellite link, or other condition, the radio is said to be flywheeling. When flywheeling, the radio’s clock is free-running off internal clocking and is no longer synchronized to any source. If the original sync source is restored to the flywheeling radio’s configuration, it attempts to synchronize to this signal without causing transmission interruption.When the flywheeling radio runs independently for long periods of time, the synchronization signal may be too far outside the capture range of the synchronization loop, and portions of transmission frames can be lost during this re-synchronization process. This condition is temporary and all interconnected radios will re-synchronize to the sync source, as necessary.If the flywheeling period is exceeded, the radio will stop transmitting. There is a setting for infinite flywheeling; however, long periods of flywheeling can cause interference with collocated radios.Virtual Local Area Network (VLAN)VLAN segments information in a single connection and creates multiple separate connections to secure information of one type or for one set of users from other information types or for other sets of users. Exalt’s VLAN communications implementation adheres to the IEEE standard 802.1q.In most cases, an Exalt radio acting as a Layer 2 bridge between two locations is only required to pass traffic with VLAN tagging. Without additional configuration, all Exalt radios support frame sizes in excess of 1900 bytes, which currently supports all defined VLAN packet sizes. Some situations require Exalt radios to act upon VLAN traffic and perform any or all of the following functions:•Connect specific traffic, using VLAN tagging, to different purposes, such as management traffic to the radio’s NMS system.•Allow only traffic with specifically assigned VLANs to pass across the link, blocking all other VLANs or any non-VLAN traffic.•Allow management access only through a VLAN connection, leaving the main traffic transparent.•Allow management access without a VLAN connection, but flowing only specific VLAN traffic across the link.Link SymmetryThe default configuration of ExtendAir (TDD) Series radios provides 50/50 symmetrical throughput. The Tx/Rx Throughput Ratio setting enables programming different symmetry for applications where significantly higher throughput in one direction is anticipated such as for video broadcast, video aggregation, or remote server/storage WANs. Exalt does not recommend placing two links with asymmetry back-to-back in a serial configuration due to the TDD cycle of the radios. This configuration requires that one radio transmits in an overlapping time period while another radio is receiving. Physical antenna isolation and/or frequency channel spacing may accommodate this configuration. Asymmetry is, however, ideal for single-hop, multi-link hub/spoke architectures, or simply single independent links.Note: If an application only requires the transparent passing of VLAN traffic, disable the VLAN function.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 172013-02-22TDD frame sizes of 2ms and 5ms are supported. The 5ms configuration maximizes the aggregate throughput of the radio for every situation. The 2ms configuration reduces latency to meet latency-critical applications, especially for multi-link and TDM circuit support. The following RF BW/mode combinations are supported for these two configurations:•16MHz/Mode1 (called 20MHz/Mode1 for some regulatory domains)•16MHz/Mode2 (called 20MHz/Mode 2 for some regulatory domains)•16MHz/Mode 3 (called 20MHz/Mode 3 for some regulatory domains)•32MHz/Mode1 (called 40MHz/Mode 1 for some regulatory domains)•32MHz/Mode2 (called 40MHz/Mode 2 for some regulatory domains)•32MHz/Mode 3 (called 40MHz/Mode 3 for some regulatory domains)The following Tx/Rx ratios are supported for these two configurations:•65/35 and 35/65•80/20 and 20/80For example, a radio configuration of 32MHz/Mode2 with a 5ms TDD frame size supports up to 110Mbps user capacity or 55Mbps full-duplex. By selecting 80/20 on one side of the link and 20/80 on the other side, the radio allows up to 88Mbps in one direction, and 22Mbps in the opposite direction.T1/E1 is supported with asymmetric settings. However, based on the BW/mode setting (and in some cases, TDD frame size and distance), the direction with the limited throughput limits the number of T1 or E1 connections obtained. For example, the 16MHz/Mode1 setting typically supports up to 27Mbps aggregate throughput. In the 80/20 ratio configuration, one direction is limited to 5.4Mbps, which is less than 3xE1 and less than 4xT1. Since TDM connections must be symmetrical, this setting therefore limits throughput to no more than 2xE1 or 3xT1.Simple Network Management Protocol (SNMP)The Exalt radios primarily use a browser-based graphical user interface (GUI) for radio configuration and management, as described in Exalt Graphical User Interface (GUI). In addition, a command line interface (CLI) is provided for serial and/or Telnet access, as described in Configuration and Management. SNMP is often used for management of larger networks as described here. Use SNMP to manage networked devices and execute the following functions:•GET: Obtain information from the device, such as a configuration setting or parameter.•SET: Change a configuration setting on the device.•TRAP: The device proactively informs the management station of a change of state, usually used for critical alarms or warnings.Note: Asymmetry is only supported for a specific subset of system configurations that are optimized for typical asymmetric applications.Note: The 80/20 configuration is not supported for 32MHz/Mode3, because the capacity of the 100BaseT interface is fully utilized at 65/35 configuration for this setting.Note: GPS sync is supported with asymmetric settings, but in addition to the other requirements for sync, all radios tied to sync must be set with matching ratios.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios18 203591-0112013-02-22One feature of the SNMP implementation is that system configuration changes do not take effect using the SET command. Instead, groups of configuration settings can be preconfigured for global change, and a single ‘Save’ (Commit) command implements all changes.When some parameters are changed, a link may drop and/or management control lost. MIB files allow many parameters to be set at once, allowing only a temporarily dropped link or management control issue. The opposite end radio can be quickly reconfigured, with little downtime for the link and management control. The save (Commit) command is similar to the Update button. Dropped links or management control issues do not occur with every parameter change. Many configuration changes do not impact traffic or management access.Exalt radios utilize SNMPv3, a high security version of SNMP, to ensure secure access to and storing of management data. The SNMPv3 security string matches the admin and user passwords. Passwords must be eight characters or longer. Some models also have legacy SNMP support for customers requiring SNMPv1 and/or SNMPv2.Note: MIB files can be downloaded on the File Transfer Page.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 192013-02-22System Installation and Initiation ProcessThe tasks required for radio installation and initiation are outlined in the following figure.Figure 9   Radio installation tasksPath & Site AnalysisLink DesignBuild Antenna Structures & EgressMount Antennas & Transmission LineInstall & Test Network & Power WiringRead This Manual CompletelyPre-configure RadiosPerform Back-to-Back TestMount RadiosConnect Transmission LineConnect PowerAlign Antennas to Planned RSLVerify LEDs for Good LinkTest Network ConnectivityConnect & Test Primary ServicesTest Network Management SystemBoth Transmission System & Radio Preparation Tasks Must Be CompleteTransmission System Tasks Radio Preparation Tasks
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios20 203591-0112013-02-22Record KeepingAfter installation, record the following items for ongoing maintenance and future troubleshooting. Keep a record for each end of the radio link and store a copy of these records at the radio location, at the opposite end radio location, and a central record storage location.•GPS coordinates for antenna locations at each site•Antenna heights above ground level (AGL), as mounted•Antenna model numbers, serial numbers, and specifications•Antenna polarization as mounted•Length/type of primary transmission lines at each site•Model number and serial number of RF lightning arrestors•Length/type of secondary transmission line(s)•Transmitter output power setting as installed at each site•RSL as measured after antenna alignment at each site•Designed RSL per original design at each site•RSL reading with far-end power off (from each end)•Spectrum analyzer plot with far end off at each site•Voltage standing wave ratio (VSWR)/return loss at radio’s antenna connector at each site•Radio’s network management IP address at each site•Radio’s network management gateway address at each site•Radio’s operating frequency, bandwidth setting, and mode of operation•Optionally purchased extended warranty and/or emergency service contract detailsIn addition, certain information may be desired for central record-keeping only:•Link security codes and log in passwords (stored in a secure place)•Photographs of complete installation•End-user sign-off/acceptance documentation (if any)•Photo of product identification label (part number, serial number, MAC address information)•Electronic copy of radio’s configuration file•Electronic copy of radio’s installed software
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 212013-02-22InstallationThis section presents all tasks required to install the Exalt Digital Microwave Radio.Mechanical Configuration and MountingThe ExtendAir (TDD) Series radios are environmentally sealed units intended for deployment outdoors. The device must be deployed within an ambient temperature range as specified, and with non-restrictive airflow around the chassis. The rc models can also be mounted in an enclosure or indoors. The same airflow and temperature conditions apply. All integrated antenna models can be mounted behind a window if window losses are considered in the link budget calculation.Provide proper clearance for all cables and connectors attached to the device. Note that for the rc models, the RF cable connector may require significant clearance for the bend radius of the coaxial cable assembly. All RF connectors, cables, and adapters must be rated for operation within the radio’s frequency range. RF connector losses must be accounted for within the link engineering design and output power settings.Mounting the SystemUse the mounting system supplied with each terminal for wall or pole mounting (Figure 10). The pole mounting kit can accommodate a pole 2–5"/5–13cm in diameter. Install the mounting system first, and then affix the radio to the mount. The radio can also be affixed to the mount, and the entire assembly (including radio) mounted.Figure 10   Pole-mount example (integrated antenna version)For rc models, the mounting solution is a very simple single bracket, using the same pole-mounting band clamps with the same specifications.For the integrated antenna model, it is critical to mount the entire device at the predetermined location for proper path clearance to the link end. Ensure that there is adequate space around the mounting system and the radio to allow for antenna alignment for both azimuth and elevation adjustments.Note: The power injector and power supply must be placed indoors or in an enclosure.Note: Mount the rc models as close as possible to the antenna to minimize the length and associated losses of RF cabling.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios22 203591-0112013-02-22Radio Ports and IndicatorsThis section provides a brief overview of the connectors, controls, and indicators on the device. Details about each item are in other sections of this document. Figure 11 shows the connectors on the ExtendAir (TDD) Series radios.Figure 11   ExtendAir (TDD) Series connectors (model r5000)Connector OverviewThe primary user interfaces are shown in Figure 12. Table 2 provides details of the connectors. Detailed pin structures for each connector are in Interface Connections.Table 2  ConnectorsConnector DescriptionSYNC/RSL (1) Sync In for TDD Synchronization (from Exalt GPS or second radio or ExaltSync Collocation Kit).(2) Sync Out for TDD Synchronization (to a second radio or through ExaltSync Collocation Kit to multiple radios).(3) Antenna alignment RSL voltage (during installation).TDM 2&4 Ports for up to two user T1 or E1 circuits to traverse link, port numbers 2 and 4.TDM 1&3 Ports for up to two user T1 or E1 circuits to traverse link, port numbers 1 and 3.Power/ETH1 Connected cables traverse to the power injector (Data+Power side), and provide the following functions:• Primary ports for user Ethernet data (10BaseT or 100BaseT) to traverse link• DC power from power injectorETH2 and ETH3 Ports for additional Ethernet connections, management and/or traffic. (xx05 models only).(Ground) Threaded (M5) receptacle.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 232013-02-22LED IndicatorsTable 3 provides details of the LED indicators on the ExtendAir (TDD) Series radios. Note that there are two LEDs, labeled top and bottom, associated with each connector. See Alarms Page for information on how the Exalt GUI displays LED status. RESET ButtonThere is only one external control on the ExtendAir (TDD) Series radios system, a button labeled “RESET” which is located on the Power Injector. This button performs two functions: critical system parameter reset and summary alarm information.Use the reset function if the IP address and/or passwords are lost. Use the following steps to perform a critical parameter reset:Use a connector cover on all unused connectors for weatherproofing. The connector covers are included in the accessory kit. Use a safety ring on each connector to secure the connector covers.Table 3  LED indicatorsLocation Type FunctionGPS/RSL Top Green LED Solid when valid GPS connection is detected.GPS/RSLBottom Green LED UnusedTDM 2&4Top Green LED Solid when T1 clocking is present for input #2.TDM 2&4Bottom Green LED Solid when T1 clocking is present for input #4.TDM 1&3Top Green LED Solid when T1 clocking is present for input #1.TDM 1&3Bottom Green LED Solid when T1 clocking is present for input #3.ETH2 or ETH3Top Green LED UnusedETH2 or ETH3Bottom Green LED Solid when valid when Ethernet Link is present. Blinking when Ethernet traffic is present.Power/ETH1 Green LED Solid when proper power is applied.Power/ETH1Bottom Green LED Solid when Ethernet link is established.Blinking when Ethernet traffic is present.Power InjectorDATA+POWERLeft Green LED Solid when no alarm conditions are present. Flashing when in alarm condition.While RESET button is pressed:Solid when in major alarm condition (traffic affecting).Flashing when in minor alarm condition (not traffic affecting).Off when no alarm conditions are present.DATA+POWERRight Green LED Solid when proper power is applied.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios24 203591-0112013-02-221Remove power from the radio by disconnecting the AC adapter from the power injector.2Hold down RESET button on the power injector while applying power. Hold the RESET button down through the whole power cycle and monitor the DATA+POWER left LED on the power injector. Release the RESET button only after the LED is in the steady state (1 to 3 minutes, depending on firmware installed). 3Release the RESET button.The following configurations are reset on the radio:•IP address = 10.0.0.1•IP mask = 255.0.0.0•IP gateway = 0.0.0.0•Administration password = password•User password = password •VLAN = disabledA flashing left DATA+POWER LED on the power injector indicates that alarm conditions exist on the radio. To access summary alarm information during normal operation, press and hold the RESET button. The following is status for the left the DATA+POWER LED while holding the RESET:•Solid on is a link alarm (link is down or errored)•Flashing indicates a minor alarm (does not affect traffic) PowerThe radio requires a DC power source within specifications. DC can be provided from a DC battery source, central lab/rack supply, or from the supplied AC adapter. Terminating the RF Connectors (rc models)Before applying power, the RF connectors must be properly terminated into a 50-Ohm load. If this is not performed, the radio may be damaged by simply applying power. Also, there are human safety factors to consider regarding potentially harmful RF radiation.The following lists a few simple ways to achieve proper termination:•Connect a 50-Ohm coaxial termination device to the RF port of the radio. The termination must be rated to 1W (or more). Example(s) include:– Broadwave Technologies P/N 552-200-002, or similar•Connect the complete transmission system. That is, the RF cabling including the antenna. The cabled antenna provides a proper termination for the RF output.•Connect a fixed (or a series of fixed) 50-Ohm attenuator(s) to the RF connector, either directly or at the end of an RF transmission line. The attenuator must be at least 30dB as specified at the operating frequency and rated for a minimum of 1W input power. Examples include:– Broadwave Technologies P/N 352-103-xxxNote: Read this section completely before applying power.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 252013-02-22– Bird 2-A-MFN-xx– JFW Industries 50FP-xxx-H6-NCover any unused connector with the connector cap and apply the weather-seal tape. Both cap and tape are included in the accessory kit.Optional AC PowerThe optional AC power injector kit easily connects to the customer-supplied CAT5e PoE cable. Refer to the input voltage requirements stated on the label affixed to the adapter to ensure that the adapter can be used with the AC mains supply.The AC plug outlet provided with the adapter may need to be replaced to match the country configuration. The adapter cable uses a standard connector for this cable for use of a pre-wired cable appropriate to the outlet configuration. If the appropriate cable is not available, the existing AC plug end can be severed and a replacement plug affixed. Consult a qualified electrician for this activity.Do not plug the adapter into the mains power. First, verify that the RF connector is properly terminated (see Power), and then plug in the radio-side connector from the AC adapter to the radio. If the AC mains can be turned off using a switch, disable the power, plug the AC side of the adapter into the AC mains socket, and then enable power to the circuit. If the AC mains cannot be turned off, plug in to the AC main socket to apply power. Verify that the radio is active by observing LED activity on the injector and radio. All LEDs on the radio flash at initial power cycle.Exalt strongly recommends that the AC mains supply be fused or on a separate breaker to ensure against over-voltage and/or over-current situations and to provide some form of protection to the radio electronics and other devices connected to the same supply. In addition, if the AC power is subject to significant spikes or variation, power conditioning is a worthwhile investment, as the quality of mains power may have a direct impact on the device operation, performance and/or reliability. An Uninterruptible Power Source (UPS) or other form of battery-backed system protects against brown-out and black-out conditions, and condition the power presented to the adapter.Evaluate the opportunity for lightning or other similar surges to be present on the powering system, including the ability for surges to couple to the power wiring system. If an evaluation indicates that there is a potential likelihood for these conditions to occur, additional surge protection is recommended for the input power wiring, especially to protect the radio electronics between the adapter and the radio’s DC input connector.The above statement is similarly true for every wired connection to the device. While the configuration for surge suppression or line conditioning is of a different type for each kind of signal interface, the opportunity for damage to the device, loss of communications and property is significant. In some cases, there can also be a risk to human life by not protecting against lightning entering a building through wiring or improper grounding. If you do not have experience in this type of installation practice, consult a qualified electrician and/or telecoms professional during the installation and wiring of the equipment.Optional DC Power InjectorThe ExtendAir (TDD) Series radios use a power injector (sold separately) to send DC power to the radio over the CAT5e cable, and including the Ethernet connections. Figure 12 shows the power injector connectors that connect the AC adapter (included with the system) and the radio.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios26 203591-0112013-02-22Figure 12   Power injector connectors1Connect the network Ethernet connection to the DATA connection of the power injector. 2Connect the cable for the radio to the DATA+POWER connection of the power injector.3Ground the power injector using the grounding receptacle. The injector can also be mount wall using the bottom panel brackets. CAT5e Lightning/Surge ProtectionTo provide for human safety and for the safety of connected network equipment, it is highly recommended to place a weatherproof lightning suppression device at the egress point where the CAT5e cable(s) enter the building, shelter, or cabinet. To protect the radio equipment, install a weatherproof lightning suppression device near the radio for all connected CAT5e cables.For the Power/Ethernet cable, specific voltage requirements must be met. The following devices are the only devices currently recommended:•Polyphaser IXG-05•Transtector ALPU 1101-959•Transtector ALPU 1101-898•Transtector ALPU-1000BT-R•Transtector ALPU-EXLT•Transtector ALPU-90vUse a short CAT5e cable for the connection between the radio and the first arrestor. Use bulk outdoor-rated CAT5e cable for the longer run between arrestors, and indoor- or outdoor-rated cable with a standard CAT5e termination for the connection from the egress arrestor and power injector.If the radio arrestor is deleted from the design, Exalt resellers can supply a longer cable with the proper weatherproof connector for the connection from the radio to the egress arrestor.Apply this same method for the TDM connections. There are no special requirements for lightning arrestors. Vendors, such as Transtector and Polyphaser, offer single and multiple TDM weatherproof arrestors. Note that each connector on the radio can carry up to 2 TDM (Time Division Multiplexing) connections.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 272013-02-22Reset to Critical Factory SettingsIf necessary, the radio terminal may be reset to critical factory settings. This may be necessary if the IP address and/or passwords for the system are not known. All other configurations are left at their current settings. If a complete default factory configuration is desired, load the Default Configuration File into the system, as described in System Configuration Page.The following parameters are configured after a reset to critical factory settings:•IP Address = 10.0.0.1•IP Mask = 255.0.0.0•IP Gateway = 0.0.0.0•Administration password = password•User password = password•VLAN = disabledAntenna/Transmission SystemThis section provides guidance to mounting and connecting the RF transmission system, which consists of the antenna, RF cabling, and RF lightning arrestors. Consult the manufacturer’s instructions for proper mounting, grounding, and wiring of these devices, and for definitive direction. These manufacturer’s instructions supersede any information in this section. See Table 7 for a list of supported antennas.Initial Antenna Mounting (rc models)The antenna must be an exact model recommended by the path and site planning engineer(s). Mount the antenna at the proper height, mast/mounting location and polarization orientation as determined by the path and site planning engineer(s). The model type, location, and orientation of the antenna is critical with respect to achieving proper path clearance, as well as to mitigate external or self-interference from nearby or collocated systems operating in or near the same frequency band.The antenna structure must be secure and safe with respect to the mounting of the antenna, transmission system weight, radio housing, and the combined weight of any personnel that may climb or attach to the structure. The combined weight of items and forces on the structure must be carefully considered in the design and construction of the structure. This must include the weight bearing on the structure in the highest wind conditions possible in the region, and with respect to all objects affixed to the structure. If additional objects are affixed to the structure in the future, it may be important to evaluate both the mechanical impact of these planned additions (with respect to wind and weight loading), as well as the Note: Use only outdoor-rated UV-resistant CAT5e cable. This cable must have an outer diameter between 0.25"/6.35 mm and 0.31"/7.87mm. Belden 1300A is recommended. Securely hand-tighten all connectors on the ODU to ensure a weatherproof seal.Warning! Mount the antenna in a restricted area and in a manner preventing long-term human exposure to the transmitted RF energy. To comply with FCC and Industry Canada regulations, the minimum safe distance from the antenna for continuous human exposure is 10'/3m.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios28 203591-0112013-02-22potential impact to RF interference and frequency coordination (if additional radio equipment is anticipated). This is especially important if future equipment is likely to operate within the same frequency band. Once the antenna is mounted, cabled, and aligned, your goal is to never require modification. This prior planning is important in the path and site planning stages and in construction of the antenna structure.Follow the antenna manufacturer’s instructions for mechanical mounting of the antenna. Ensure that there is enough room around the antenna for alignment activities (moving the antenna in vertical and horizontal arcs), and for the RF transmission line to connect to the antenna connector unobstructed and within the specified bend radius requirements of the transmission line.At this point, the antenna mounts should be fully secure to the structure, the feed of the antenna securely mounted to the antenna (if the feed is a separate assembly), and the azimuth and elevation adjustments not completely tightened in preparation of the antenna alignment activity. It is a good practice to connect the transmission line to the antenna connector as early in the process as possible, to reduce the opportunity for debris or moisture to enter either the antenna connector or the transmission line connector. Use a connector cover or other temporary measures to ensure that the connector is kept clear. Take extra care if the antenna is installed during inclement weather to ensure that no moisture gets inside the antenna connector at any time.Now the antenna can be aimed in the general direction required for the link. Use a compass, a reference bearing, binoculars or any other similar device to point the antenna in the direction (generally) of the far end radio, and then slightly tighten the azimuth and elevation adjustments so that the antenna maintains its general position and is safe to be left without additional securing. Refer to the Exalt white paper, Antenna Alignment, for more information on antenna alignment techniques.Transmission Line from Antenna to Radio (rc models)Most installations use a very short length of coaxial transmission line for the connection between the antenna and the radio device. Coaxial transmission line can either have a solid or braided shield. Solid-shield cables are more resistant to external signal coupling and interference, but are generally stiffer than braided cables. Consult the path or site engineer(s) to ensure that the proper materials are chosen for the installation and that all factors were considered.Generally, the larger the diameter of the transmission line, the lower the loss. So for longer runs of transmission line, larger diameter cables are highly advised. However, at every frequency, there is a maximum diameter cable that supports the operating frequency. Verify the specifications. This should is determined in the path and site planning process.Table 4 lists representative samples of transmission line types recommended for the Exalt Digital Microwave Radio.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 292013-02-22It is critical that the transmission line and antenna be capable of supporting the same type of connector, or easily adapted. It can be important to minimize the number of connectors and adapters, and it is ideal that they match directly without adaptation. In most cases, transmission line allows for N-type male connectors and antennas have N-type female connectors.If possible, connect the primary transmission line directly to the antenna. It is desired to have the fewest possible pieces of transmission line in the system, to minimize losses and points of failure from connectors. The antenna can typically accommodate a direct connection if planned in advance. Use a 90º adapter for the connection to the antenna, if necessary, but confirm that all connectors and transmission lines are properly specified for the operating frequency with minimum loss, proper impedance (50 Ohm) and proper VSWR characteristics. Transmission line connector termination is a critical element of the installation. Many ‘factory built’ RF transmission lines do not provide the proper characteristics for proper transmission, despite their published specifications, often due to the fully or semi-automated process of factory termination, which may not have considered the frequency of your system. When buying pre-terminated transmission line, it is strongly advised to obtain the documentation of test measurements on the connected transmission line showing that the loss characteristics and VSWR are within the specified limits specifically at your operating frequency. In addition to factory-built transmission line, self-terminated transmission line can suffer the same issues. The manufacturers of transmission line typically offer instruction and certification for transmission line termination, and may also provide videos illustrating the process. There is no amount of extra care, education, precision, and effort that can be overstated for this process. There is often a need for a small excess of transmission line near the antenna to accommodate both the need for extra slack as the antenna is loosened and moved for the alignment process, and to accommodate a drip loop for the transmission line and the initial transmission line securing hardware and grounding near the antenna. In addition, the transmission line is typically very stiff, and can provide undue pulling force on the antenna or radio connector. Take care to align the cable with the connector so that it does not provide any torque or strain on the connector. Consult your transmission line manufacturer for the proper transportation, hoisting, securing, and grounding process. Always be very mindful of the entire length of transmission line to ensure that the transmission line is never twisted, kinked, or over-bent beyond the specified bend radius. Once a Table 4  Recommended transmission lineManufacturer Type Description Loss at 4.9GHz Loss at 5.3GHz Loss at 5.8GHzAndrew LDF4-50 1/2-inch solid shield 5.6dB/100' 5.7dB/100' 6.0dB/100'Andrew LDF4.5-50 5/8-inch solid shield N/A 4.4dB/100' 4.7dB/100'Times LMR-600 1/2-inch braided shield 6.8dB/100' 6.9dB/100' 7.3dB/100'Times LMR-900 5/8-inch braided shield N/A 4.6dB/100' 4.9dB/100'RFS LCF12-50J 1/2-inch solid shield 5.5dB/100' 5.6dB/100' 5.9dB/100'RFS LCF12-58J 5/8-inch solid shield N/A 4.5dB/100' 4.8dB/100'Caution: Always follow the manufacturer’s termination process EXACTLY, and only use the manufacturer’s authorized tools and connectors for a given transmission line type.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios30 203591-0112013-02-22transmission line is over-bent or kinked, it will likely never recover its specified characteristics, even after straightening, and will often be completely unusable. The opposite end of this primary transmission line typically terminates at the radio connector. If using a long transmission line (in excess of 3'/1m), an RF lightning arrestor is recommended to protect the radio equipment.As soon as practical, weatherproof the connected ends of the transmission line to the antenna and lightning arrestor and radio. This process should be delayed as long as possible to ensure that all systems are working properly before applying the weatherproofing. Once weatherproofing is applied, it may have to be removed for testing or installation modification. With this in mind, if the installation is occurring during inclement weather, take extra care at all times to ensure that no moisture enters any connector at any time. If moisture is suspected to have compromised the antenna or transmission line, it may render those devices useless without any means for remedy except for full replacement.Cap and weatherproof the second antenna connector on the radio if using a single-polarity antenna.Indoor MountingOn rare occasions the antenna can be mounted indoors behind a window. In these cases, there would not be a need for drip loops or an RF lightning arrestor. Use a very short transmission line connected directly between the antenna and the radio mounted nearby. The weatherproofing process can also be omitted.RF Lightning ArrestorRF lightning arrestors provide a direct path to ground for lightning strikes that may couple to or directly hit the outdoor transmission system or antenna structure. The RF lightning arrestor prevents any associated voltage and current from entering the radio equipment, other equipment, or humans.The following lightning arrestors are examples of proper devices for Exalt Digital Microwave Radios:•Polyphaser AL-LSXM•Citel PRC5800Mount and ground the RF lightning arrestor in accordance to the manufacturer’s recommendations. Place it as close as possible to the radio equipment. Minimize the distance to the radio to lessen the opportunity for lightning to couple to or strike the unprotected section of transmission line (if any). Consult a qualified electrician or installer in all cases of grounding and lightning arrestor implementation.Antenna AlignmentAntennas must be installed at both ends of the planned link to commence precision alignment. Refer to the Exalt white paper, Antenna Alignment. The ExtendAir (TDD) Series radios have an integrated antenna.Antennas are typically aligned using the radio hardware for precise alignment. However, there are many very useful tools available to aid in this process, inclusive of devices specifically designed for the purpose of aligning antennas. Some examples are:•XL Microwave Path Align-R•Teletronics 17-402Use of these devices may be extremely advantageous as compared to using the radio, because they employ many unique facilities to aid in this process. Using these tools also makes it possible to align
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 312013-02-22the antennas before the radio equipment is delivered. However, many installers successfully use the radios as the means for antenna alignment.The following are the primary facilities when using the radio to align the antenna:•RSL voltage connection using a volt meter (recommended)Insert the included adapter into the GPS connector on the radio housing and the opposite end connected to a volt meter.The RSL test point DC voltage is inversely proportional and numerically calibrated to the received signal level. The voltage rises as the antennas are less in alignment, and falls as antennas are more in alignment. The voltage measurement corresponds to the received signal level in measurements of dBm (a negative number for RSL measurements). For example, an RSL of -60dBm yields an RSL voltage measurement of 0.60VDC; an RSL of –45dBm measures 0.45VDC.•Audio alignment buzzerEnable the audio alignment buzzer through the Exalt GUI. When enabled, the radio enclosure emits a sound. The pitch rises when higher (better) levels of RSL are achieved. Align the antennas until the highest pitch is accomplished. The tone is continuous when the two ends of the radio system are in communication. Otherwise, the buzzer beeps.•Exalt GUI RSL reading indicates the current RSL in dBm.Note: There is a slight delay in RSL readings in the GUI as the RSL levels change. In this case, fine alignment can be done in small adjustments allowing a small gap of time so that the impact of the adjustment on the GUI display catches up to real time.Note: Only use the browser-based GUI for antenna alignment if there are no other means available. If this method is required, refer to Exalt Graphical User Interface (GUI). The RSL reading can be read on a PC or any handheld computing device that supports an HTML browser and Ethernet connectivity.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios32 203591-0112013-02-22Configuration and ManagementThis section describes the command line interface (CLI) and Exalt graphical user interface (GUI).Telnet into the Command Line Interface (CLI)Use a Telnet connection to access the CLI in the Exalt Digital Microwave Radios. Use the CLI to set key parameters on the system.Connect to the Radio in a Telnet SessionMake the Telnet connection to the radio through the Ethernet port. Use Windows and perform the following steps:1Open a command prompt or MS-DOS prompt (Start>Run).2Type C:\>Telnet <IP Address> at the command line:The default IP address is 10.0.0.1TelnetUse Telnet when prompted to enter the administration level login and password. The default administration login is admin and password is password. It is recommended that the default administration password be reset by performing a radio reset (see Reset to Critical Factory Settings).Figure 13 shows the three menu choices available after log in.Figure 13   CLI main menuThe following selections can be made on all screens:•0 = back to previous screenNote: The accessing computer must be on the same IP subnet as the radio. If the radio has DHCP enabled on the PoE port (see Ethernet Interface Configuration Page), which is the default setting for a radio shipped from Exalt, and your computer's Ethernet port is set for DHCP addressing, the radio will configure your computer to 10.0.0.2, and no manual IP configuration is required for your computer.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 332013-02-22•9 = help•Ctrl+\ (control and backslash keys) = exit sessionExalt Graphical User Interface (GUI)The Exalt GUI is the primary user interface for configuring and troubleshooting the radio and radio system. A computer or hand-held device with a conventional HTML browser and Ethernet port is required. Microsoft Internet Explorer is the preferred browser. Firefox, Chrome and Safari are also supported.Preparing to ConnectIf the radios are new, both radios are preconfigured as Radio B, and have the same IP address. The initial priority is to configure one radio to Radio A and assign different IP addresses, unique to each radio. There are two ways to change the IP address:1Reset the radio to the critical default factory settings (see Radio Reset).2Connect to the GUI using the default IP address (10.0.0.1), and change the IP address through the GUI interface.To configure a radio as Radio A, connect to the GUI and change the configuration, as discussed in this section.Make ConnectionsIt is recommended that one radio at a time be configured, on a bench, before taking the radios to the field for installation:•(rc models only) Terminate the RF connector with a 50-Ohm termination or a fixed attenuator of at least 20dB (see Power).Once connected to the radio using Ethernet, log in to the Exalt GUI.Note: To connect to the radio’s Ethernet port and use the GUI interface, the accessing computer must match the radio’s IP address subnet. It is therefore necessary to either change the radio’s IP address through the CLI to match the subnet of the computer, or change the computer’s IP address to match the subnet of the radio (such as, a computer IP address of 10.0.0.10 if trying to connect to a radio set to the factory default IP address of 10.0.0.1).If the radio has DHCP enabled on the PoE port (see Ethernet Interface Configuration Page), which is the default setting for a radio shipped from Exalt, and your computer's Ethernet port is set for DHCP addressing, the radio will configure your computer to 10.0.0.3, and no manual IP configuration is required for your computer.Note: Do not connect the radios in a back-to-back configuration. If the radios are set to their factory default settings, both radios are configured as Radio B and cannot communicate. Both radios also have the same IP address, which causes IP address conflictsNote: The IP address subnet of the accessing computer must match the radio’s IP address subnet to connect using Ethernet.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios34 203591-0112013-02-22Log InUse the following steps to log in to the Exalt GUI.1Open a browser window. Microsoft Internet Explorer is the recommended browser. Netscape, Mozilla, and Firefox are also supported. If there are issues with your browser, please report it to Exalt Customer Care. You may be required to use a different browser to immediately overcome issues.2Type the IP address of the radio in the address bar.Figure 14   Initiating the browser connectionThe following window displays after pressing the Enter key or clicking the Go button in the browser window.Figure 15   Browser Login screenLogin PrivilegesThere are two levels of login privileges:•Administrator (admin) – assigned complete permissions to view, edit, and configure•User (user) – assigned limited, view-only permissions with no edit or configuration rightsThe default login names and passwords are as follows:Table 5  Default login informationPrivilege level User name Default passwordAdministrator admin passwordUser user password
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 352013-02-22Administrator login credentials are required for configuration purposes. Type the user name and passwords for Administrator level and click OK. The following screen displays.Figure 16   Radio Information pageQuick StartTo establish a link on the bench, apply the following basic configurations to the radio terminal. Use the steps in the Quick Start Guide included with the radio. A summary of the items that need to be configured are:•Radio IP address for each end. – Each end must have a different IP address and cannot match the accessing computer’s IP address or any address assigned if radios are part of a larger network.– It may be required to change the IP address of the accessing computer after changing the IP address of the radio so that the IP subnet matches.– The radio IP address is listed on the Administration Settings Page.•Set one radio as Radio A.– The radio selected as Radio A must be configured.– Radio A/B selection is the Endpoint Identifier parameter on the System Configuration Page.– Even though both radios are set as Radio B by default, confirm this configuration on the radio intended to be Radio B.If all other parameters are still configured at their factory default settings, the radios can now be connected back-to-back to verify that the link is communicating and perform any other desired tests. See Back-to-back Bench Testing for test information.Note: Click the Update button to save changes on any page. Also on all pages until saved, changed fields display with an orange background.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios36 203591-0112013-02-22Navigating the GUI describes each page of the GUI. Most configuration parameter settings are intuitive. The following link parameters must match at both ends for the link to communicate:•Link Security Key (Administration Settings Page)•Bandwidth (System Configuration Page)•RF Frequency (System Configuration page)•Link Distance (System Configuration page)•TDD Frame Size (System Configuration page)Navigating the GUIThe GUI provides the primary interface for all configuration and management. There are three sections of the main GUI window:•Summary status information section (upper-left corner)•Navigation panel •Main windowFigure 17   Exalt GUI window descriptionSummary Status SectionThis section of the Exalt GUI provides a review of the system status. In the screens in Figure 17, the top bar illustrates the alarm condition of the link. The information inside the bar is equivalent to the entry of the Link Name set by the administrator in the Administration Settings Page.The color of the panel indicates alarm status: Note: Changing any of these parameters causes a temporary loss of link. The GUI displays a warning and provides an opportunity to cancel changes.Click the radio IP address link to access that radio for management.SUMMARY STATUSNAVIGATION PANEMAIN WINDOWLINK TOREMOTE RADIO
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 372013-02-22•Green indicates the system is communicating and all functions are normal•Yellow indicates a minor non-traffic affecting alarm condition •Red indicates a major traffic affecting alarm condition The left panel summarizes the alarm conditions of the local radio (the radio that matches the IP address). The information displayed is the IP address and the endpoint identifier (Radio A or Radio B). The right panel summarizes the alarm conditions of the remote radio (the radio linked to the local radio).The Summary Status Section allows the Exalt GUI to be a rudimentary management system. Minimize the browser window to display just the top bar or the top bar and radio information, and open several browsers on the desktop. When a window status changes to yellow or red, you can quickly maximize that window to determine the issues.Figure 18   Summary status informationNavigation PanelIn the navigation panel, pages with sub-pages have a plus (+) to the left of the page link. Click the plus sign or page name title to view sub-page titles. The pages can be collapsed to hide the sub-pages when a minus (–) sign appears to the left of the page link.Management pages are indicated with an X to the left of the page name. Click the X or page name to display the page within the main window.Note: The ‘local’ radio might be the near-end or the far-end radio, depending on the management interface connection. The terms local and remote refer to the orientation of the radio terminals relative to the IP address you are managing. When making certain changes to a near-end radio without first making changes to the far-end radio, the link may become disconnected unless configuration changes are reverted to their original settings. When making changes that may disrupt the link, always change the far-end radio first, and then the near-end radio to match.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios38 203591-0112013-02-22Note: The ‘local’ radio might be the near-end or the far-end radio, depending on the management interface connection. The terms local and remote refer to the orientation of the radio terminals relative to the IP address you are managing. When making certain changes to a near-end radio without first making changes to the far-end radio, the link may become disconnected unless configuration changes are reverted to their original settings. When making changes that may disrupt the link, always change the far-end radio first, and then the near-end radio to match.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 392013-02-22Radio Information PageThis page provides general information about the local radio terminal. This information is helpful for troubleshooting and for record keeping. Figure 19   Radio Information page
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios40 203591-0112013-02-22Administration Settings PageThis page allows contains general parameters for the radio system. The Current Value column lists entries actual settings. Desired changes are entered in the New Value column.After all desired changes are entered, click the Update button to accept and enable changes. Figure 20   Administration Settings pageMost entries on this page are self-explanatory. The following lists unique or important parameters.•Fill in the date and time fields as soon as practical. Events are captured with time/date stamps, which is valuable information for troubleshooting.•Set the Link Security Key to something other than the factory default setting (12 characters, all zeros) at each end. The link security key must match at both sides of the link. If the security key remains at the factory setting, the radio link is open to sabotage by a party with the same radio model. Each link should have a unique security key. If using the same security key for every link in the network, the radio could link to any other radio with the same security key. This is problematic in multi-radio networks.– Note that the security key must be exactly 12 characters. Any printable ASCII character can be used. The link security key is case sensitive.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 412013-02-22– Reset the admin and user passwords. These passwords should not match. If the admin password remains at the factory default setting, it provides an opportunity for random reassignment by a network-connected user.– The new password must be entered twice. If the passwords do not match and the Update button clicked, the password is not changed and remains set to the previous password.•Enter the license key provided by Exalt to access extended features or diagnostic capabilities. Click Update to accept the changes and enable the new features. License keys are issued by radio serial number, so ensure that the license key used was issued for this particular radio.•AES Advance Encryption Standard) can be implemented to provide additional data security for the wireless link. This function requires an upgrade license key (purchased separately). Both radios in the link must have a valid AES upgrade license key to implement AES. Different bit-length encryption license keys (for example, 128-bit and 256-bit) are also available, depending on model type. If the required upgrade license key is present, simply insert a matching ASCII string on both terminals and select the Enable AES On option for AES encryption. Note that similar to the administration and user passwords, the AES string must be entered twice for each terminal.Note: Changing the link security key interrupts transmission until the opposite end is changed to match. Always change the far-end radio first, and then change the near-end radio.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios42 203591-0112013-02-22NTP and Time Zones Configurations PageUse this page to set the Network Time Protocol (NTP), number of NTP client(s), and local time zone.Figure 21   NTP and Time Zones Configurations page
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 432013-02-22Simple Network Management Protocol (SNMP) ConfigurationUse SNMP to manage networked devices and execute the following functions:•GET: Obtain information from the device, such as a configuration setting or parameter.•SET: Change a configuration setting on the device.•TRAP: The device proactively informs the management station of a change of state, usually used for critical alarms or warnings.Figure 22   SNMP Configuration pageOne feature of the SNMP implementation is that system configuration changes do not take effect using the SET command. Instead, groups of configuration settings can be preconfigured for global change, and a single ‘Save’ (Commit) command implements all changes.When some parameters are changed, a link may drop and/or management control lost. MIB files allow many parameters to be set at once, allowing only a temporarily dropped link or management control issue. The opposite end radio can be quickly reconfigured, with little downtime for the link and management control. The save (Commit) command is similar to the Update button. Dropped links or management control issues do not occur with every parameter change. Many configuration changes do not impact traffic or management access.ExtendAir radios utilize SNMPv3, a high security version of SNMP, to ensure secure access to and storing of management data. The SNMPv3 security string matches the admin and user passwords. Passwords must be eight characters or longer.The SNMP MIBs are organized similar to the GUI. Become familiar with the GUI before using the SNMP function.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios44 203591-0112013-02-22SNMP v1/v2c/v3 Support OptionsEnable the SNMPv1/v2c options to allow entering read and read/write community strings. Enable the SNMPv3 options to allow entering read and read/write user names and passwords. These entries are de-coupled from the standard radio user names and passwords. SNMPv3 provides full management security.SNMP TrapsSNMP traps alert the central network management system with important issues about the radio system. Trap filters are set on the Traps Configuration page (). Not all i-Series radios support SNMP traps. Consult the release notes for more information. Trap support for all versions of SNMP are provided and can be independently enabled. Enter the IP address to which the traps are directed in the Trap Destination IP Address field. The AUX port (or the MAIN port when using in-band management) must be connected to the network to allow trap information to reach the designated IP address. In a bridged network, this may not require special network settings. In a routed network, the connected router must have a defined path for the IP address.Figure 23   Trap Configuration pageThe following traps are available:•Authentication Trap: This is an SNMP standard trap when password information for SNMP is incorrect. This can help identify unwanted intrusions into the management system and for diagnosis of SNMP issues for valid users.Note: Users are encouraged to avoid enabling SNMPv1/V2c support due to known security loopholes in these protocols.Note:  The Update button must be clicked to save any changes to this page.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 452013-02-22•Radio Reboot Trap: This trap is sent after any radio reboot to inform the manager of the reboot status.•Local/Remote Link Status Trap: This trap is sent when Link is in errored state (equivalent to the Link LED on the radio front panel or the Link status bar in the upper-left of the Exalt GUI window).•Local/Remote Status Trap: This trap is sent when Status is in errored state (equivalent to the Status LED on the front panel or the radio status box in the upper-left of the Exalt GUI window).•Local RSL Status Trap: This trap is sent when the local RSL drops below the value set in the Threshold Value (dBm) field. Buffers are provided so that continuous traps are not sent if the RSL is bouncing near the set threshold value. This trap is reset only if the RSL rises to 3dBm above the set threshold value and then drops below that value. Exalt recommends that this trap be set to a value 5dBm or 10dBm above the threshold as a warning that the system has faded and may be approaching an outage.•Temperature Status Trap: This trap is sent when the internal temperature reaches the warning point. This conveys that the external temperature control is in a fault state. Buffers are applied to this trap to avoid multiple traps when the temperature remains near the warning point.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios46 203591-0112013-02-22File Management PagesFile Transfer PageThis page allows the administrator to upload and download files to and from the radio. Two types of files can be uploaded: configuration and radio firmware. When uploading Configuration Files, current configuration parameters are immediately overwritten, and the unit automatically reboots. When uploading radio firmware files, the file is placed into reserve memory space. After the new radio firmware file uploads, use the File Activation page to enable the files (see File Activation Page).Figure 24   File Transfer pageUp to four types of files can be downloaded: configuration, radio firmware, radio event log, and MIB. The MIB file refers to the Management Information Base related to the Simple Network Management Protocol (SNMP) function, and is only available on models which support SNMP. See Simple Network Management Protocol (SNMP) for more information.Use the following steps to download a file.Note: Check the File Activation Page before uploading radio firmware files. New file uploads overwrite the secondary file location. If important files reside in the primary or secondary file location, download them before uploading the new files. Only the active radio firmware file can be downloaded. Therefore, to download the reserve file, it must first be activated (using the Swap button). See File Activation Page. The current radio firmware and RDD versions can be viewed on the Radio Information Page.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 472013-02-221Select the type of file to download (configuration or radio firmware).2Click the Download button and wait for the radio to prepare the file for download. For the MIB file download, a second page/link appears (Figure 25). 3Left-click the link on the page to download the file to a desired location.Figure 25   File Transfer page—download file linkFile download and upload is useful when configuring several radios with similar settings. A copy of the configuration file can also help restore radio settings. In addition, a copy of the Exalt default configuration file is helpful to restore the radio to factory settings. If copying the same configuration file into multiple radios, some parameters will match and that may be undesirable. However, it may be easier to change just a subset of parameters rather than every parameter. The following parameters can cause problems or confusion if they match at each of a link:•Radio Name•Endpoint Identifier•IP Address•IP Subnet Mask•Default Gateway The following parameters can match at both ends of the link:•Link NameNote: Do not change the name of any download file. The configuration file must be named config.nv. To keep track of multiple configuration files, use a folder naming system or temporarily rename the file, however, it must be named config.nv before it can be uploaded to a radio. Never change radio firmware file names under any circumstances.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios48 203591-0112013-02-22•Link Security Key (although each link should be different)•Admin and User passwords•Bandwidth•RF Frequency•Link Distance•TDD Frame Size•T1/E1 configurations•Ethernet configurations
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 492013-02-22File Activation PageUse this page to move stored or uploaded files for use on the radio. The page indicates which file is currently in use, and which file is available for use. Click the Swap button to place the file in the Alternative File column into the active state and move the file in the Current File column to the Alternative File column.Figure 26   File Activation pageNote: In all cases, the radio reboots after a new file is selected using the Swap function. This places the radio out of service for a short time.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios50 203591-0112013-02-22System Configuration PageThis page contains several critical system parameters. Figure 27   System Configuration pageMost entries on this page are self-explanatory. The following lists unique or important parameters.•Set the Endpoint Identifier so that one end of the link is set to Radio A and the opposite end set to Radio B. In single-link networks, it is unimportant which end is designated A or B. In multi-link networks, however, it may be important to orient the links so that at any collocation site (where there are multiple radios of the same type at the same site), all radios are set to the same Endpoint Identifier (A or B). See Link Orientation and Synchronization. •Set the Radio Transmit Power (dBm) parameter to the designed level. The professional installer sets this value or dictates the value of this setting to the system administrator following the system design and local regulations. In many cases, this value must be set to a proper value to comply with legal restrictions. Improper values can result in liability to the user and/or installer.Note: Changing the Endpoint Identifier parameter requires a reboot of the radio to take effect. The reboot temporarily interrupts traffic.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 512013-02-22– Do not adjust the Radio Transmit Power parameter to a value higher than is legally allowed. – Do not adjust the Radio Transmit Power parameter lower than the link budget and fade margin can afford. •Set the Bandwidth (MHz) parameter to the designed level. The value of this is determined in the design/engineering stage. The Bandwidth parameter must also match at both ends of the link. In conjunction with the Mode parameter, the Bandwidth parameter directly relates to the capacity, latency, and the number of TDM circuits supported. The transmitter and receiver bandwidth are modified using this parameter, making it critical that it be set with respect to the local RF noise and interference profile, and/or in relation to any multi-link network design.•Set the Mode parameter to the designed selection. The value of this setting is determined in the design/engineering stage. The Mode parameter must match at both ends of the link. In conjunction with the Bandwidth parameter, the Mode parameter setting directly relates to the capacity of the system, as well as critical RF parameters, including receiver threshold, carrier-to-interference ratio, and in some cases, maximum radio transmit power.•Set the RF Frequency (GHz) parameter to the designed point. The value of this setting is determined in the design/engineering stage. RF Frequency must match at both ends of the link. It may be critical to set RF Frequency with respect to the local RF noise and interference profiles, and/or in relation to any multi-link network design.Note: Changing Radio Transmit Power may temporarily interrupt traffic. Small changes in output power do not normally interrupt traffic, but larger changes may.Note: The link may be lost and unrecoverable through GUI control. If the link is lost due to reduction of Radio Transmit Power, travel to the radio location(s) may be required to reset the value.Note: Changing Bandwidth will temporarily interrupt traffic. The Bandwidth parameter must match at each end. Adjust the far-end radio first, and then the near-end radio. Changing Bandwidth changes the radio’s threshold. A narrower bandwidth has better threshold performance and improved interference immunity, therefore if changing to a wider bandwidth, there is an opportunity that the link may be lost and unrecoverable through GUI control. Check the available fade margin and interference profile to determine if the impact to threshold and increased bandwidth is acceptable to maintain the link and the desired performance. If the link is lost due to increasing the Bandwidth parameter, travel to the radio location(s) may be required to reset the value.Note: Changing Mode will temporarily interrupt traffic. The Mode setting must match at each end. Adjust the far-end radio first, and then the near-end radio. Changing Mode changes the radio’s threshold, carrier-to-interference ratio, and also may have impact on the Radio Transmit Power. A lower mode has better threshold performance and carrier-to-interference ratio, and in some cases, higher output power, therefore if changing to a higher mode (for example, from Mode 1 to Mode 2), there is an opportunity that the link may be lost and unrecoverable through GUI control. Check the available fade margin and interference profile, and determine if the impact to RF performance is sufficient to maintain the link and desired performance. If the link is lost due to increasing the Mode parameter, travel to the radio location(s) may be required to reset the value.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios52 203591-0112013-02-22The frequency selection section includes the ability to select from either the complete list of frequencies (“All”) that can be tuned for the selected band and bandwidth, or, in some cases, a pre-selected list of non-overlapping center frequencies (“Preferred”) that Exalt determined provides the most flexible collocation opportunities for large networks of Exalt radiosThe frequency selection section includes a band selection button that must be enabled for the frequency band of operation for which the link was engineered. In some cases, some bands may not be selectable due to regulatory constraints. Some bands also require Dynamic Frequency Selection (DFS). DFS is automatically enabled for these bands and is selectable for all other bands.•Enable the ACS (automatic channel switching) option to allow the radio to re-tune the operating frequency when radar or high noise interference is detected. This can reduce the opportunity for interference in other radios in the network. See Automatic Channel Selection (ACS) Page. To prevent losing the link, ACS must be enabled on both Radio A and Radio B.•DFS is automatically enabled for any band where required based on regulation. For bands where DFS is not required, it can still be selected. For DFS to operate properly, set the antenna gain figure to match the installed transmission system gain (that is, the gain of the antenna minus all losses between the radio and the antenna). •Set the Link Distance (miles) parameter to the range that is equal to or greater than the actual link distance. The value of this setting is determined in the design/engineering stage.•Set the TDD Frame Size (ms) parameter to the designed level. The value of this setting is determined in the design/engineering stage. The TDD Frame Size parameter must match at both ends of the link. The TDD Frame Size parameter setting directly relates to the capacity, latency, and number of TDM circuits that can be supported over the given link distance. In multi-link networks, especially where there are collocated links, it is also important to set all radios to the Note: Changing RF Frequency will temporarily interrupt traffic. The RF Frequency parameter setting must match at each end. Adjust the far-end radio first, and then the near-end radio. If the RF Frequency parameter is changed to a frequency with interference, the link may be lost and unrecoverable through GUI control. If the link is lost due to changing the RF Frequency parameter, travel to the radio location(s) may be required to reset the value.Note: When DFS is enabled, the radio temporarily stops transmitting for at least 60 seconds to ensure that no radar interference is present. This is called Channel Availability Check (CAC). The DFS status displays on the Alarms Page. Once CAC passes, the radio resumes normal operation. If at any time during CAC or regular operation a qualifying radar signature is detected, the radio shuts down communications for a minimum of 30 minutes. This is the Non-Occupancy Period (NOP). Transmission only resumes after the NOP completes and then only after a successful CAC.Note: Changing the Link Distance parameter will temporarily interrupt traffic. The Link Distance setting must match at each end and must not be less than the actual link distance. Adjust the far-end radio first, and then the near-end radio. If the Link Distance parameter is changed to a setting less than the actual distance, the link may be lost and unrecoverable through GUI control. If the link is lost due to this situation, travel to the radio location(s) may be required to reset the value. If the Link Distance parameter setting is set to a distance unnecessarily higher than the actual link distance, the radio may have substantially reduced performance with respect to throughput and latency.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 532013-02-22same TDD Frame Size setting to avoid self-interference. Future enhancement: The GPS or internal sync function may be necessary for these networks. See Time Division Duplex (TDD) Factors and Link Orientation and Synchronization for more information.•Set the TX/RX Throughput Ratio (%) parameter to program radio symmetry. The default setting is 50/50 for symmetrical, full-duplex throughput. Other throughput ratio options are 20/80, 80/20, and 65/35, 35/65. See Link Symmetry.– For asymmetric throughput, only TDD frame size settings of 2ms and 5ms and RF Bandwidth settings of 16MHz and higher are supported. – The 64MHz/Mode2 configuration does not support asymmetry due to capacity limitations of the 100BaseT interface. Set the Radio Collocation parameter to control parameters related to the GPS Synchronization feature (see Radio Synchronization). •Radio Collocation parameters can be enabled when an Exalt GPS receiver is connected to Radio A or when using internal sync between two collocated radios or when using the ExaltSync Collocation kit to synchronize multiple radio links at one location. There are two additional features:– Set the Flywheel Period parameter to ‘Normal’ (default) or ‘Infinite.’ This is the period of time that the radio will run on the internal timing signal if the synchronization timing signal is lost. –The Normal parameter is a time period that allows the timing signal to be recovered. The default time to wait is set between 5 and 10 min. The system then resynchronizes to the timing signal without impact to traffic. If Normal is selected and timing is not recovered within the set time period, the system stops transmitting (loss of link) until timing is recovered. This prevents self-interference to local systems, but loses the link. –The Infinite parameter allows the radio to run on the internal clock source with no limit and attempts to resynchronize with the timing source when the timing source is detected. This allows the link to continue to operate, however, if a timing signal is not detected within approximately 10 minutes, the radio may start to cause interference to other collocated systems, and other collocated systems may start to cause interference with it. If after this interval timing is restored, a temporary outage due to the resynchronization requirement may occur.– Set the Tx Timing Offset (µSec) parameter to allow the administrator to delay transmitter timing from the GPS timing pulse by a fixed time, in microseconds. This is useful if multiple GPS-synchronized Exalt radio systems are present, separated by distance, such as when using a repeater. This delay is required to offset the difference in speed-of-light between the two locations. It is recommended to add a 5uSec delay for every mile of difference in path length. For example, if there is one link with no delay, delay the link within the field-of-view of the first link on the same or overlapping frequency channel accordingly so that it is synchronized, including the speed-of-light delay between the two sites.– When using Internal timing, select the radio to be the Sync Source (master) for the other collocated radios, Sync Auto for a radio to receive sync and run indefinitely if sync is lost (this Note: Changing the TDD Frame Size parameter will temporarily interrupt traffic. TDD Frame Size parameters must match at each end. Adjust the far-end radio first, and then the near-end radio. If the TDD Frame Size parameter is set to a value that cannot be supported for the link distance, the link may be lost and unrecoverable through GUI control. If the link is lost due to this situation, travel to the radio location(s) may be required to reset the value.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios54 203591-0112013-02-22provides the same results as infinite flywheel parameter), or Sync Recipient, which disables a radio if sync is lost, but eliminates the opportunity of self-interference.•Buzzer Timeout (minutes) parameter creates an audio signal for antenna alignment. Turn on the buzzer continuously during antenna alignment or preset a period of time that the buzzer will sound. If the buzzer stops before alignment activities are complete, change the selection and press the Update button or select the ON option until alignment activities are complete.•Aggregate User Throughput parameter provides information about user capacity of the wireless link, in the current configuration. The ‘new value’ column reflects throughput if changes are made to Bandwidth, Mode, Link Distance, and/or TDD Frame Size. Click the “Aggregate User Throughput” link for details on aggregate capacity.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 552013-02-22Ethernet Interface Configuration PageThis page allows administrators to set the alarm, and duplex settings of the Ethernet connection. Figure 28   Ethernet Interface Configuration page (multiple Ethernet ports model)•For models with multiple Ethernet ports, NMS Management allows determination of the management information using the following management modes:– In-band: Management traffic is carried over the air and is available from all connectors on either end of the link.– Out-of-band: Management traffic is not carried over the air and is only available from the port(s) configured for Management. – Port-to-Port: Management traffic remains separate from data traffic without requiring out-of-band management or VLAN configuration. This allows any Ethernet port on the link to be logically mapped to the same port at the other end of the link without requiring VLANs to be configured. The traffic passing through these mapped ports is not accessible from any of the other available Ethernet ports on either side of the link.•Set the Ethernet ports on the radio and connected equipment to 100/full-duplex for best performance. If the Ethernet ports are set to auto-negotiation, poor throughput performance may be a result, as well as intermittent disconnections of the Ethernet connection. •The Flow Control setting allows the enabling of 802.3 Ethernet flow control, useful for systems implementing QoS or other traffic flow control implementations.•The Alarm function can be enabled or disabled for each port. Generally, all constantly connected port alarms should be enabled, and unused or maintenance-only ports should have alarms disabled. •For models with multiple Ethernet ports, the Mute setting allows signalling to connected network devices when the radio link is down such as for spanning tree protocol.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios56 203591-0112013-02-22•When enabled, the DHCP feature provides a basic DHCP function to ease interfacing with a computer. DHCP is enabled by default. If the Ethernet port on the computer is set for DHCP addressing, on radio bootup (for up to 10 minutes) or when an Ethernet link is sensed for a management port, the radio provides an IP address to the computer that is two digits higher than the radio’s IP address (for example, if the radio’s IP address is 10.0.0.1, the computer’s IP address will be 10.0.0.3). The radio also senses any DHCP server on the network and if detected, mutes its own internal DHCP function.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 572013-02-22T1/E1 Configuration PagesThese pages allow the administrator to selectively enable or disable the T1 or E1 circuits, one at a time. For enabled T1/E1 circuits, additional configuration, including loopback functions, are available. Disable the unused T1 or E1 so that the alarms are turned off and more throughput is allocated to the Ethernet interface. Every enabled T1 or E1 input, even if there is no T1 or E1 signal present, reduces the aggregate throughput of the Ethernet interface by roughly 3Mbps (for T1) or 4Mbps (for E1).This page toggles between T1 and E1, as required, by clicking the Set to T1 or Set to E1 button. A warning displays that a reboot is necessary, and the radio reboots if the administrator continues. This will interrupt traffic. It may be necessary to re-login to the radio after the reboot completes. T1/E1 mode self-coordinates across the link if the link is active. This means that it only needs to be set while connected at one end. In addition, enabling and disabling T1/E1 circuits also self-coordinates across the link if the link is active. If a link is not active and T1/E1 enabling is a mismatch when a link is first created, the Radio A configuration for T1/E1 enabling supersedes the settings on the Radio B configuration, and changes the settings on Radio B.T1 Interface Configuration PageThis page allows the administrator to enable/disable each individual T1 channel, set the Line Build Out (LBO), Line Code (either AMI or B8ZS), and AIS enabling/disabling for each input. If enabled, the radio places an AIS code on the output of the associated interface if and when the link fails or when there is no T1 signal available from the far end to provide the user at the local end. Loopback controls are also provided (see T1/E1 Loopback).Note: Certain combinations of the TDD Frame Size, Link Distance, Mode, and Bandwidth parameter settings limit the number of T1/E1 circuits that can be carried by the radio. In these cases, certain fields on the T1/E1 Interface Configuration pages are not available, starting with the highest port number. For example, for a 4x T1/E1 radio version, if only three (3) circuits can be carried, port 4 is not available for configuration and is disabled. If only two circuits can be carried, both ports 3 and 4 are not available. Increasing the TDD frame size and Mode parameters, and/or increasing the Bandwidth parameter results in an increase in the supported number of T1/E1 circuits.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios58 203591-0112013-02-22Figure 29   T1 Interface Configuration pageE1 Interface Configuration PageThis page allows the administrator to enable/disable each individual E1 channel. The AIS can also be enabled and disabled for each input. If enabled, the radio places an AIS code on the output of the associated interface if and when the link fails or when there is no E1 signal available from the far end to provide the user at the local end. Loopback controls are also provided (see T1/E1 Loopback).Figure 30   E1 Interface Configuration page
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 592013-02-22T1/E1 LoopbackLoopback is provided for any enabled T1 or E1 port. As shown in Figure 29 and Figure 30, the choices are:•No Loopback (default) •External (local)•External (remote)•InternalAll loopback configurations control the loop at the Line Interface integrated circuit, which is the device wired directly to the front panel ports.External loopback modes are used in conjunction with an external test source. The designation of ‘local’ or ‘remote’ refers to where the loopback is occurring relative to the location where the loopback is implemented. That is, on the radio being accessed, if External (remote) is selected, this loops the signal back at the remote radio interface back towards the local radio. Likewise, if External (local) is selected, the signal loops back at the local interface towards the remote radio (Figure 31 and Figure 32).Figure 31   External (remote) loopbackFigure 32   External (local) loopbackWhen a local T1/E1 port is configured for External (remote) loopback, it is the same as configuring the remote radio for External (local) loopback.Internal loopback uses an internal test source, and sends the test source signal across the link, looped at the remote radio’s interface, returned to the local radio, and looped at the local radio’s interface back to the source. The inputs at both ends are looped back at the line level. Figure 33 illustrates the internal loopback function.Figure 33   Internal loopbackNote: Only one Internal loopback can be enabled at any time.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios60 203591-0112013-02-22VLAN Configuration PageVLAN is disabled as the default setting for Exalt radios. The Exalt radios still pass VLAN and non-VLAN traffic across the link, but do not examine the VLAN traffic or act upon it. Enable VLAN using the Exalt GUI for expanded VLAN support.Figure 34   VLAN Configuration pageVLAN configurations are maintained even when VLAN is disabled. That is, the VLANs can be configured and the configuration saved, even though they are not active until VLAN is enabled. Use the following methods to restore the management connection if a mistake was made assigning the management VLAN and access cannot be restored: Reset the radio to the critical factory defaults (see Reset to Critical Factory Settings). Connect to the Console port using a serial interface and the CLI, as described in Telnet into the Command Line Interface (CLI), and reconfigure the VLAN settings.Four VLAN configurations are provided:•802.1q Block Untagged: To pass desired VLANs across the radio, they must be listed in the lower tables per their respective interfaces. All other traffic, including untagged traffic, is not passed across the link. The radio must be managed on a VLAN whose ID is set in the upper table. This management VLAN ID is available to any interface IDs listed in this lower table.Note: Once a management VLAN is configured or modified and the Update button clicked, the management connection will likely be lost. The management connection to the radio must follow the configuration to the assigned VLAN. After configuring and enabling the management VLAN on the radio, reconfigure your network’s management access to match the settings on the radio.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 612013-02-22•802.1q Pass Untagged: To pass desired VLANs across the radio, they must be listed in the lower tables per their respective interfaces. All other VLAN traffic is not passed across the link, and untagged traffic is passed across the link with no changes. The radio must be managed on a VLAN whose ID is set in the upper table. This management VLAN ID is available to any interface IDs listed in this lower table.•802.1q Tag Untagged: To pass desired VLANs across the radio, they must be listed in the lower tables per their respective interfaces. All other VLAN traffic is not passed across the link, and untagged traffic is tagged with the programmed Default VLAN, per interface, as set in the upper table. Any interface requiring the default VLAN ID to pass must have the Default VLAN ID listed in the table below. The radio must be managed on a VLAN whose ID is set in the upper table. This management VLAN ID is available to any interface IDs listed in the lower table.•Management only: All traffic is passed transparently, except the radio is managed on an assigned Management VLAN ID, as programmed in the upper table.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios62 203591-0112013-02-22Ethernet Rate LimitingThis page enables radio Ethernet port rate limiting. Enable this to limit the output information rate to at or below downstream networking equipment capabilities. The rate is in Mbps or kbps, as specified.Figure 35   Ethernet Rate Limiting pageFor models with more than one Ethernet port, each port can have rate limiting enabled or disabled. The default setting is disabled.Use the Update button to save changes.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 632013-02-22QoS Configuration PageThis page provides configuration for the Quality of Service (QoS) feature (not available on all models). QoS is a network prioritizing feature that ensures high-priority traffic transfers during peak capacity demands. The priority hierarchy is adhered to when capacity demand is higher than the link can provide; highest priority traffic is allowed to transfer, while lowest priority traffic may be dropped. Figure 36   QoS Configuration page (multiple Ethernet interface model)These systems follow a ‘round robin’ QoS algorithm, ensuring a distribution of priority traffic. Some percentage of all priority classifications is carried across the link, with the largest percentage applied to the highest priority, and next largest percentage to the next highest priority, and so on. Thus low-priority traffic is not ignored when there is a high capacity high-priority traffic stream.The following QoS Mode options are available (choose one per port):•MAC DA (Media Access Control Destination Address): Prioritizes traffic based on the MAC destination address (recipient of the traffic) in the packet header.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios64 203591-0112013-02-22Figure 37   MAC DA based QoSUp to 8 MAC destination addresses can be programmed per port for priority queuing, as shown in Figure 37.•MAC SA (Media Access Control Source Address): As with MAC DA, prioritizes traffic based on the MAC source address (sender of the traffic) in the packet header. Up to 8 MAC source addresses can be programmed per port for priority queuing.•VLAN ID (Virtual Local Area Network Identifier): Prioritizes traffic based on the VLAN ID tag in the packet header.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 652013-02-22Figure 38   VLAN ID based QoSA maximum of 64 VLAN IDs can be programmed across all ports for priority queuing, as shown in Figure 38. If the radio has multiple Ethernet ports and any port is set for VLAN ID based QoS, all VLAN ID based QoS ports share the VLAN ID programming for QoS. •802.1p: Prioritizes traffic based on the 802.1p tag in the packet header.802.1p based QoS supports the tag range 0–7 (Figure 39), each tag can be assigned to the priority queues (0–3). If VLAN filtering and VLAN ID based QoS are enabled, all VLAN IDs listed for QoS must also be listed on the VLAN Configuration Page.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios66 203591-0112013-02-22Figure 39   802.1p based QoS mode•IPv4/IPv6: Prioritizes traffic based on the IP tag in the packet header.IPv4/IPv6 based QoS supports the tag range 0–63 (Figure 40), each tag can be assigned to the priority queues (0–3).Figure 40   IPv4/IPv6 based QoSFor radios with multiple Ethernet ports, different QoS modes can be set for each port. However, if more than one port is assigned the same VLAN ID, 802.1p, or IPv4/IPv6 QoS mode, those ports share those settings and they cannot be altered within that port.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 672013-02-22•Port (models with multiple Ethernet ports only): Prioritizes traffic based on the Ethernet port (Figure 41); all traffic connected to the port is assigned to that priority queue.Figure 41   Port based QoS modePriority 3 is the highest priority traffic; priority 0 is the lowest. The default priority queue is assigned to any traffic that does not comply to the selected priorities. For example, if MAC DA or MAC SA is selected and a packet comes in that does not match any of the up to eight programmed addresses, it is assigned to the queue selected as default, as are packets that do not have a VLAN ID, 802.1p, or IPv4/IPv6 tag, or those tags do not match any tags listed (in the case of VLAN).
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios68 203591-0112013-02-22Automatic Channel Selection (ACS) PageUse this page to configure alternate channels that the radio uses to automatically re-establish the link in the event of qualified radar detection (for DFS enabled radios) or if the trigger parameters are exceeded. Define up to ten alternate channels. Up to five channels can be enabled at the same time. Figure 42   Automatic Channel Selection pageACS is disabled by default to prevent accidental interference to other systems in the vicinity or impact multi-site frequency planning in the event of a channel switch, particularly in collocated environments designed to operate on the same channel or predefined traffic asymmetry configurations.Enable ACS to configure alternate channels. Enter the desired frequency for up to ten alternate channels. Only up to five channels can be enabled at any time. Clicking Update saves the settings and pushes the configuration to the other radio on the link if the link is currently operating in both directions. ACS configuration is not enabled until the ACS option on the System Configuration Page is selected and Update selected.Note: To preserve the link, both Radio A and Radio B must have ACS enabled and the channel frequency settings must match. If only one radio has ACS enabled and an ACS event is detected, that radio will switch channels and the other radio will not, and the link will be lost.Note: If an event is detected that triggers ACS, traffic is interrupted.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 692013-02-22The status fields have the following color indicators:•Red/Inactive: The channel is configured, but is not currently in use by the system. The radio is not currently tuned to this channel.•Yellow/Active without Link: The channel is configured and the radio is tuned to that channel, but has not established a link with the other end.•Green/Active with Link: The channel is configured, and the radio is tuned to that channel and has established a link with the other end.•Black/Temporarily inactive: DFS is enabled and the system detected a qualified DFS radar in this channel, the channel is disabled for 30 minutes.The system selects alternate channels sequentially. If the radio is operating on Channel #1, it selects Channel #2 first, then Channel #3, and so on, until a link is re-established with the far-end. If the radio is operating a channel other than Channel #1 and the Treat first entry as preferred option is selected, the search always starts with Channel #1. Otherwise the search is sequential starting from the channel of the operating frequency. Radio A wait times are approximately 35 seconds per channel switch. Radio B channel switch wait times are approximately 7 seconds. Radio B is listening for Radio A on each frequency, and may cycle through the channel list multiple times before Radio A is detected and the link re-established. Wait times are affected by this, and can be as long as 3 minutes, assuming that a link can be established on at least one frequency on the enabled list. Adjusting BER thresholds to a higher BER value such as 10(-3) can improve wait times.The BER threshold and time above BER threshold options trigger channel switching when ACS is enabled. Available BER threshold options are from 10(–3) to 10(–7). The time above BER options are in increments from 1 to 200 seconds. The defaults are 10(–5) and 10 seconds, respectively. Adjusting BER thresholds to a higher BER level and/or increasing the timer length for BER, reduces ACS activity.All ACS events are captured in the event log and can be accessed in real time for troubleshooting. Corresponding status alarms are also captured in the event log and display on the Alarms Page.•ACS must be enabled on the System Configuration Page on both radios or the link may be permanently lost. •To avoid link loss, include a setting for the current frequency before enabling ACS. When Dynamic Frequency Selection (DFS) is enabled due to regulations, expect an additional one minute wait time per channel switch. For some regulatory domains, the wait time is increased to 6 minutes per channel switch for certain frequencies.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios70 203591-0112013-02-22Syslog Configuration PageSyslog serves as a remote means to receive event log messages (configuration and alarm state changes) for network management and/or record keeping.Figure 43   Syslog Configuration pageTo enable the syslog, check the Remote host logging option and input the IP address for the remote host. See Event Log Page for filter descriptions.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 712013-02-22GPS Information PageThis page provides information on how many GPS satellites are within the view of the Exalt GPS receiver. This page is active for implementations that include the GPS receiver connection for synchronization. This information can be helpful for troubleshooting GPS issues.Figure 44   GPS Information page
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios72 203591-0112013-02-22Alarms PageThis page provides an easy-to-read summary of the alarm status of both local and remote radios. The colors on this page reflect the color of the alarms displayed on the radio front panel. However, additional detail displays on this page to aid in quick assessment of issues and status.Figure 45   Alarms pageTable 6 lists alarm status conditions that appear on this page.Table 6  Alarm status indicatorsLabel StatusLink  Indicates RF link status:• Green Solid = Error-free connection (BER<10e-6)• Yellow Solid = Errored connection (10e-3>BER >10e-6)• Red Solid = No link (BER>10e-3)DFS (enabled models only) Indicates the status of the Dynamic Frequency Selection (DFS).• Green = No DFS activity, normal transmission• Red = Either CAC or NOP is in progress.Collocation Indicates the enabled/disabled status with Internal or GPS sync and current alarm status.• Green Solid = Sync enabled and sync input present• Yellow Solid = Sync enabled and missing proper sync input in flywheel operation period• Red Solid = Sync enabled and missing proper sync input signal and flywheel period expired
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 732013-02-22The Temperature alarm monitors the internal temperature of the unit based on specific points inside the radio chassis. It is normal for the internal temperature to be above the ambient temperature, so the temperature reading may be higher than the highest specified ambient temperature. When the internal electronics reach a point that is higher than the normal temperature rise at the highest ambient temperature, the temperature alarm turns yellow. Power down the radio as soon as possible, and investigate the cause of the temperature rise before the radio is put back into service. In almost all cases, a temperature alarm is due to an external cause. Ethernet • Green Solid = Alarm Enabled and Ethernet Link present• Red = Alarm Enabled and Ethernet Link not present• Grey = Alarm Disabled T1/E1 Input • Green = Enabled and connection present (clocking confirmed)• Red = Enabled and no connection present• Grey = Disabled and no connection presentTemperature • Green Solid = Normal temperature range• Yellow Solid = Exceeding normal temperature rangeTable 6  Alarm status indicators (Continued)Label Status
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios74 203591-0112013-02-22Performance PageThis page provides statistical information about the performance of the system in relation to the integrity of the user data and the RF link. Figure 46   Performance page•The Current BER field indicates the current bit error rate of the link. If the link is operating perfectly, this should indicate zero. Generally, the link should remain at a BER less than 1x10-6 (1 bit out of every million bits errored). This is the threshold performance specification and the standard to which the link was engineered. However, radio links can and are affected by weather, interference, and other external sources and will occasionally have a higher error rate. A link remains operational unless the BER exceeds 1x10-3 (1 bit out of every hundred bits errored). Consult the link design engineer for an understanding of the predicted error rate of the radio link as it has been designed. Many applications are unaffected by bit errors, but TDM circuits (for example, T1 or E1) are more sensitive. Also, if the link operator is providing a service guarantee, this value may need to be monitored or examined in cases of service issues. The behavior of BER in relation to other alarms or measurements and external events can be very helpful in troubleshooting activities.•Current RSL is the measurement of the received signal level at the radio antenna port. This is the measured level of the RF signal coming from the opposite end of the radio link. The link was engineered to a specific RSL by the link design engineer, and this RSL should be obtained during installation and remain relatively stable during the operation of the link. RSL can and will vary as a result of weather changes and other external sources, such as path obstructions. Once again, this variation was part of the original design to achieve a certain level of performance over time. Bit errors occur when the RSL falls to a level within roughly 3dB of the threshold specification. When the RSL falls below the threshold specification, the link disconnects and will not reconnect until the RSL is above the threshold specification. The behavior of RSL in relation to other alarms or measurements and external events can be very helpful in troubleshooting activities.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 752013-02-22•Errored Seconds (ES) indicates the total number of seconds that occurred where there was at least one bit error since the last time that the radio statistics counter was reset. Generally, ES are not a significant concern, so long as they are not continuous or above the anticipated performance based on the original link engineering goals. If ES are continuous or at a high rate, this is normally an indication of poor link performance due to poor RSL or interference, or severe impact by weather or other environmental factors. However, similar to the performance factors previously listed, ES can and will occur in any radio link. Once again, consult the link engineer to determine the original design goals, and compare actual performance to these expectations to determine if any improvements are necessary or if other problems may be causing excessive ES.•Unavailable Seconds (also called UAS) are similar to ES, but this counter keeps track of every second where the bit error rate equals or exceeds 1x10-3, as well as any seconds where there is a complete loss of radio communication, over the period since the last counter reset. If Unavailable Seconds are continuous or at a high rate, this is normally an indication of poor link performance due to poor RSL or interference, or severe impact by weather or other environmental factors. However, similar to the performance factors listed above, Unavailable Seconds can and do occur in any radio link. Consult the link engineer to determine the original design goals, and compare actual performance to these expectations to determine if any improvements are necessary or if other problems may be causing excessive Unavailable Seconds.•Minimum RSL indicates the worst (lowest) received signal level that occurred since the last counter reset. It is helpful to know if the RSL dropped significantly from the normal level, or has reached a level near or below threshold.•Minimum RSL Timestamp indicates the date and time when the Minimum RSL occurred. This is helpful for general troubleshooting, and especially comparing to items in the event log or diagnostic charts from the same time period.•Maximum RSL indicates the best (highest) RSL that occurred since the last counter reset. This indicates the best performance of the radio link, which is normally equal to the installed value, and is usually the designed value.•Time Since Reset indicates the amount of time passed since the last counter reset. This helps to quantify the seriousness of other statistics, such as ES and Unavailable Seconds, if there have been high numbers of ES and/or Unavailable Seconds over a relatively short period of time.All end-of-link statistics can be independently reset using the respective reset statistics button. It is good practice to reset the statistics during link commissioning (after all antenna alignment is complete and stable RSL at designed levels is achieved, and no more system reboots are anticipated). Regularly review this page to note performance and reset the statistics so that the counters can more precisely pinpoint issues.Note: Unavailable Seconds do not register as ES. In other words, the ES counter counts all seconds that are errored NOT INCLUDING the seconds that were classified as unavailable. The total number of seconds with errors or outages is the sum of ES and Unavailable Seconds.Note: Resetting statistics from one end also resets the statistics for the same radio at the opposite end. That is, if the Local statistics are reset, logging into the remote end shows the Remote statistics on that end (which is the local radio in the first condition) as being reset at the same time.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios76 203591-0112013-02-22Event Log PageUse this page to review a list of the events logged by the radio. The following items are listed in the event log:•Alarms•Alarms clearing (Normal)•Radio RebootsEvery event is tagged with the time that the event occurred, and a severity and type. The event log also allows filtering to limit the view of the log to the lowest level of desired information. For example, a filter level of Minor displays Minor, Major, and Critical severity events. The log contains the last 1000 events. Events are deleted on a FIFO basis.The event log can be cleared and be downloaded from the radio (some models may require a software upgrade to enable this feature). A screen capture of the browser window can serve as a useful record.Figure 47   Event Log page
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 772013-02-22User Throughput PageThis page illustrates the user throughput of the radio, as configured. Figure 35 illustrates the information provided.Figure 48   User Throughput pageClick the help icon (  ) to open a page on how this information is determined Aggregate User Throughput Help page(Figure 49).
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios78 203591-0112013-02-22Figure 49   Aggregate User Throughput Help page
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 792013-02-22Diagnostic Charts PageUse this page as an aid in troubleshooting. This page illustrates the historical (and current) performance for three parameters: RSL, Radio Temperature, and BER.The horizontal scale illustrates 120 points of time measurement and is synchronized on all three graphs. The scale displays in minutes, hours, or days from the last two hours (120 minutes), five days (120 hours), or four months (120 days). All information is stored, so all of these periods are available for short- and long-term performance analysis. The right side of a graph represents the most recent measurement, and data ‘marches’ from the right-to-left at every interval.The vertical scale of each chart independently scales to show the maximum resolution based on the maximum variation of the data over the selected time measurement. Figure 50   Diagnostic Charts pageUse the cursor to point to any spot on any of the three charts, and all three charts illustrate the measurements taken for that time interval in the upper-left corner of each chart. The time interval is indicated by T=(value). This is followed by the value of the measurement, listing the highest value, lowest value and average value measured over that time interval.For example, in Figure 50 the displayed time interval is minutes, and the cursor is held at the T=17 mark on the horizontal axis. The measurements shown indicate performance from 17 minutes ago. The high/low/average values shown on each chart are measurements made across that specific one-hour interval.Changes in RSL often have an impact on BER, and this can be confirmed by looking for synchronized events. When BER events occur without corresponding changes in RSL, this normally indicates
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios80 203591-0112013-02-22interference, atmospheric changes, transmission system issues (such as problems with cables, connectors or antennas), or possibly radio hardware problems. It is also useful to help determine if changes in radio temperature are occurring, and if they are having any impact on RSL or BER. If the radio is mounted in an environmentally controlled location, this has less relevance. However, temperature monitoring can be helpful to ensure that the radio is operating within specifications.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 812013-02-22Spectrum Analyzer PageThe spectrum analyzer feature provides a useful pre-planning and troubleshooting tool. This feature is only available on radios with firmware supporting the spectrum analyzer. Perform a spectrum analysis after deployment and just before commissioning to maintain a record of the spectrum at the time of deployment. Figure 51 shows the Spectrum Analyzer page.Figure 51   Spectrum Analyzer pageWhile a professional spectrum analyzer provides higher levels of control and precision for pre-planning, the Spectrum Analyzer page allows evaluation of the RF spectrum as seen at the radio’s RF input port prior to deployment. This is useful for pre-planning the center frequency and occupied bandwidth, and to determine polarization and antenna type and mounting locations. For troubleshooting, enable the spectrum analyzer to scan the desired segment or full band of the frequency range. Select the step size and set the remote radio transmitter ON or OFF. This allows viewing of the clean spectrum without the remote transmitter on and a comparison of the remote transmitter in the midst of other signals.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios82 203591-0112013-02-22Use the smallest step size to obtain the finest view of the spectrum. The spectrum analyzer can be set to match the start and stop frequency for a dwell mode. Peak and average detection modes are also available. Peak detection is helpful for capturing intermittent events such as pulsed emissions.It is best to set the Scan Time option to a time value as opposed to using the ‘infinity’ setting. If your management computer is connected to the radio through the radio link, access to the GUI is interrupted during the duration of the analysis. The spectrum analyzer graph displays received signals in red, green or grey (Figure 52), normalized in dBm to the resolution bandwidth of the analyzer. Red indicates a peak hold function. This is the highest level detected during the entire scan. Green indicates the last value measured at that frequency. Grey indicates the lowest value detected during the entire scan. Mouse over an area to view the details above the graph. Figure 52   Spectrum analyzer graph exampleA completely grey vertical box indicates that the signal maintained a steady level for the entire scan. A mostly green box indicates that the last scan measured at a strong or stronger level than the rest of the analysis. A completely red vertical box indicates that there was a signal at some point during the scan, but that the signal was not detected at the last scan. A graph displaying green on the lower part and red at the upper part indicates that at some time during the scan, a signal was detected at a higher level than was detected during the last scan.The last spectrum analyzer scan performed displays in this page until the radio is rebooted. You can do a screen capture for record keeping and for comparison to future analyses. The time and date of the analysis displays on the page, which is handy as a reference in a screen capture.Note: Enabling the spectrum analyzer interrupts all radio traffic for the duration of the analysis. In addition, access to the radio’s GUI may also be interrupted, depending on the location of the interfaced computer relative to the radio where the spectrum analysis is occurring. The GUI is available at the completion of the spectrum analysis.Note: The result of selecting infinity may be complete loss of contact to that radio and may require a physical visit to the radio location to disable the spectrum analyzer.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 832013-02-22Ethernet Utilization PageThis page shows a chart for each Ethernet interface to illustrate inbound and outbound packet utilization. This is shown as a percentage of the interface configuration (that is, if your interface is set for 100BaseT, then 100% represents 100Mbps. Compare offered load (inbound) to delivered load (outbound) to determine if radio capacity is a bottleneck for the data transfer. This chart can illustrate inbound and/or outbound utilization, and uses different colors for data entry. The legend can be hidden.Figure 53   Ethernet Utilization pageNote that the outbound utilization never exceeds the rate where a radio is configured. For example, if the radio is configured for a 55 Mbps capacity, outbound utilization will never exceed 55 Mbps at 100BaseT.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios84 203591-0112013-02-22The watermark level function allows administrators to receive an SNMP trap when watermark conditions are exceeded. For example, if a radio is configured for 55 Mbps capacity, the administrator may wish to be warned if the radio exceeds 50 Mbps for more than 1 hour per day. In this case, set the watermark level to 50% and the trap duration to 60 minutes. Traps must be enabled for this function to be active.When the watermark level function is enabled, a line on the chart appears for data comparison to the watermark.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 852013-02-22Reboot PageUse this page to reboot the radio. The function may never be required, but can be used in emergencies. All configurations that require a reboot automatically reboot on administrator confirmation. Figure 54   Reboot page
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios86 203591-0112013-02-22Manual PageThe manual (this document or the version that matches the installed firmware) is available within the GUI. Adobe Acrobat Reader 5.5 or higher is required (go to www.adobe.com to download Acrobat Reader). Click the Manual link to display the manual within the browser window. Once the manual displays, click the save button on the PDF toolbar to download the manual locally.Figure 55   Manual page
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 872013-02-22SpecificationsThis section presents specifications for the ExtendAir (TDD) Series digital microwave radios.Physical SpecificationsIntegrated Antenna ModelsConnectorized Antenna Mode (rc models)Physical Configuration Outdoor unit (ODU)Dimensions (H x W x D) 13.3 x 13.3 x 4.5 inches / 33.8 x 33.8 x 11.4 cmWeight 7 lbs., 3.18 kgOperating Temperature –40 to +149°F /–40 to +65°C; Altitude 15,000'/4.6 km Humidity 100% condensingEnvironmental NEMA4/IP66Physical Configuration Outdoor unit (ODU)Dimensions (H x W x D) 9.4 x 9.4 x 5.25 inches / 23.9 x 23.9 x 13.34 cmWeight 6 lbs. 2.72 kgOperating Temperature –40 to +149°F /–40 to +65°C; Altitude 15,000'/4.6 km Humidity 100% condensingEnvironmental NEMA4/IP66
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios88 203591-0112013-02-22Common System SpecificationsTuning Resolution 1MHz; 5MHz for some regulatory domainsPower Control Step Size 0.5dBSelectable Modulation Modes Mode 1 (QPSK); Mode 2 (16QAM), Mode 3 (64QAM)Selectable Frame Lengths (ms) 0.5, 1, 2, 2.5, 4, 5Maximum Aggregate User CapacityError Floor 10-12Frequency Stability +7 ppmLink Security 96-bit Security Code, optional NIST FIPS-197 compliant 128-bit or 256-bit AES encryptionMbps Mode 1 Mode 2 Mode 38/10MHz 13 26 3816/20MHz 27 55 8132/40 MHz 55 109 162
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 892013-02-22System Specifications, 4.9GHz BandFrequency Band 4.940–4.990 GHzOutput Power (at full power) +24dBm, Mode 1+21dBm, Mode 2+19dBm, Mode 3Output Power (at minimum power)  0dBmSelectable Channel Bandwidths 10MHz, 20MHz, 40MHzReceiver Threshold (BER=10–6)Maximum RSL 0dBm no damageMode 1: –25dBm error-freeMode 2 & Mode 3: –30dBm error-freedBm Mode 1 Mode 2 Mode 310MHz –86 –79 –7320MHz –83 –77 –7140MHz –80 –74 –68
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios90 203591-0112013-02-22System Specifications, 4.9GHz BandFrequency Band 4940–4990MHzTunable Range 4945–4985MHzOutput Power (at full power) +21dBm, Mode 1+18dBm, Mode 2+16dBm, Mode 3Output Power (at minimum power)  0dBmSelectable Channel Bandwidths 10MHz, 20MHz, and 40MHzaa. Consult your country’s regulations or Exalt Communications to determine if 40MHz is allowed foryour application.Receiver Threshold (BER=10–6)Maximum RSL 0dBm no damageMode 1: –25dBm error-freeMode 2 and Mode 3: –30dBm error-freeNon-overlapping channels 10MHz: 5; 20MHz: 2; 40MHz: 1dBm Mode 1 Mode 2 Mode 310MHz –86 –79 –7320MHz –83 –76 –7040MHz –80 –73 –67
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 912013-02-22System Specifications, 5.3GHz BandFrequency Band 5250–5350MHzTunable Range 5260–5332MHzOutput Power (at full power) +22dBm, Mode 1 (QPSK); +20dBm 8/10MHz BW+22dBm, Mode 2 (16 QAM)+20dBm, Mode 3 (64 QAM)Output Power (at minimum power) 0dBmSelectable Channel Bandwidths 8/10MHz, 16/20MHz, 32/40MHzReceiver Threshold (BER=10–6)Maximum RSL 0dBm no damageMode 1: –25dBm error-freeMode 2 and Mode 3: –30dBm error-freeNon-overlapping channels 8/10MHz: 10; 16/20MHz: 5; 32/40MHz: 2dBm Mode 1 Mode 2 Mode 38/10MHz –86 –79 –7316/20MHz –83 –76 –7032/40MHz –80 –73 –67
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios92 203591-0112013-02-22System Specifications, 5.4GHz BandFrequency Band 5470–5725 MHzTunable Range 5488–5715 MHzOutput Power (at full power) +22dBm, Mode 1 (QPSK); +20dBm 8/10MHz BW+22dBm, Mode 2 (16 QAM)+20dBm, Mode 3 (64 QAM)Output Power (at minimum power) 0dBmSelectable Channel Bandwidths 8/10MHz, 16/20MHz, 32/40MHzReceiver Threshold (BER=10–6)Maximum RSL 0dBm no damageMode 1: –25dBmMode 2 and Mode 3: –30dBmNon-overlapping channels 8/10MHz: 29; 16/20MHz: 14; 32/40MHz: 7dBm Mode 1 Mode 2 Mode 38/10MHz –86 –79 –7316/20MHz –83 –75 –7032/40MHz –80 –72 –67
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 932013-02-22System Specifications, 5.8GHz BandFrequency Band 5725–5850 MHzTunable Range 5731–5844 MHzOutput Power (at full power) +24dBm, Mode 1 (QPSK); +20dBm 8/10MHz BW+22dBm, Mode 2 (16 QAM)+20dBm, Mode 3 (64 QAM)Output Power (at minimum power) 0dBmSelectable Channel Bandwidths 8/10MHz, 16/20MHz, 32/40MHzReceiver Threshold (BER=10–6)Maximum RSL 0dBm no damageMode 1: –25dBmMode 2 and Mode 3: –30dBm (dBm) Mode 1 Mode 2 Mode 38/10MHz –86 –79 –7316/20MHz –83 –76 –7032/40MHz –80 –73 –67
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios94 203591-0112013-02-22Interfaces RFTDM (TDM models only) Ethernet (1 interface on xx00 models, 3 interfaces on xx05 models)Sync-In Sync-OutPower — DC Power Injector (sold separately)Power — AC adapter/injector (sold separately)Integrated Antenna (r models only)Connector N-type femaleImpedance 50 OhmsConnector RJ-45 (RJ48C), femaleT1 Impedance 100 Ohms, balancedT1 Line Codes AMI, B8ZS, selectableT1 LBO Settings (in ft.) 0–133, 133–266, 266–399, 399–533, 533–655T1 Clocking Speed 1.544 MbpsT1 Compliance ANSI T1.102-1987; ITU-T; G.823; GR-49T-COREE1 Impedance 120 Ohms, balancedE1 Line Codes HDB3E1 Clocking Speed 2.048 MbpsE1 Compliance CEPT-1; G.703; ITU-T-G703Connectors RJ-45, female, auto-MDIXInterface Speed 10 or 100 MbpsDuplex Half, full, auto, selectableCompliance 802.3Connector RJ-45, femaleSignal 1pps (GPS or Internal Sync signal)Connector 6-pin barrier stripInput Voltage 48VDCConsumption <25 W (0.6A)Input 100–240VAC, 0.5AOutput 40W, 56VDCGain (midband) 23dBi3dB Beamwidth 10 degrees
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 952013-02-22Interface ConnectionsThis section provides the pin number assignment and wiring information for the connectors on the ExtendAir (TDD) Series radios. All connectors are shown as viewed from the radio rear panel, oriented with the PoE connector at the lower left corner.TDM ConnectionsThere are two connectors for TDM; each connector has two TDM circuits available. Figure 56 illustrates the pin orientation and functionality of these connectors. These connectors are disabled on the IP version radios.Figure 56   TDM connectorsRSL/Sync ConnectorThis connector can be used during the antenna alignment process, to provide a received signal level (RSL) voltage to a voltmeter. The connector is also used for connection to an optional Exalt GPS antenna for the purposes of GPS synchronization, or used to send or receive sync signals to a collocated radio, or to an ExaltSync Collocation Kit, for multiple radio sync. Figure 57 illustrates the pin orientation and functionality for this connector.Pin Function1 Tip Out (from radio) – Ch.1 & 22 Ring Out (from radio) – Ch.1 & 23 Tip Out (from radio) – Ch.3 & 44 Tip In (to radio) – Ch.1 & 25 Ring In (to radio) – Ch.1 & 26 Ring Out (from radio) – Ch.3 & 47 Tip In (to radio) – Ch.3 & 48 Ring In (to radio) – Ch.3 & 4
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios96 203591-0112013-02-22Figure 57   RSL & Sync In/Sync Out connectorTwo Radio Internal Sync Out/InIf using the Internal Sync Out/In function between two radios only, connect Pin 8 from the Sync Out radio to Pin 6 of the Sync In radio and use a straight connection for Pin 2. Connect no other pins. To ease the need to keep track of which end of the cable is for In and Out, consider cross-connecting Pins 6 and 8, with a straight connection for Pin 2. Connect no other pins.Sync Distribution AccessoryIf using a sync distribution accessory (sold separately), connect CAT5e cabling straight from the radio Sync connector(s) to the accessory.Power/Ethernet ConnectorThis connector is the primary connector on the radio, and must be connected to provide power to the radio, and primary Ethernet communications for traffic and Ethernet. Figure 58 illustrates the pin orientation and functionality for this connector.The Ethernet cable between the PoE injector (or integrated AC/injector) must be wired as a straight connection. The wiring follows typical wiring for Power-over-Ethernet (PoE), however the power consumption requirement for the ExtendAir (TDD) Series radio does not allow for ‘standard’ (802.3af) PoE, and only the Exalt power injector shall be used. In addition, the Exalt power injector provides critical reset and alarm capability that would not be available from a generic PoE injector, even if the power consumption requirement is met.Pin Function1 +5V out to GPS antenna2Ground3 Tx Data to GPS antenna4 Enable signal to GPS antenna5 Rx Data from GPS antenna6 Sync input signal7 Received Signal Level (RSL)8 Sync output signal
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 972013-02-22Figure 58   Power/Ethernet connectorPin Function1 Paired with Pin 22 Paired with Pin 13 Paired with Pin 64 +DC Power (48V) In5 +DC Power (48V) In6 Paired with Pin 37 -DC Power (48V) In8 -DC Power (48V) In
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios98 203591-0112013-02-22AntennasTable 7 lists antennas supported by the ExtendAir (TDD) Series for use in the USA. In some countries, antennas exceeding a certain level of gain may be unlawful. Refer to RF Output Power Setting for details on regulatory limits.Table 7  5GHz AntennasManufacturer Model Number Type Size/Diameter Polarization Gain (dBi)MTI MT-485049/NVH Panel 1 ft Dual 23MTI MT-485025/ND Panel 1 ft Dual 23General Dynamics EPD1-52 Panel 1 ft Single 23Mars MA-WA58-1XMNTB Panel 1 ft Single 23MTI MA-WA56-DP25N Panel 1 ft Dual 23.5RadioWaves FPD1-5-24 Panel 1 ft Dual 23.8ARC PD5823B88 Panel 1 ft Dual 24Laird PA58-24 Panel 1 ft Single 24Laird R2T58-24 Panel 1 ft Single 24RadioWaves FP1-5-24 Panel 1 ft Single 24.2Mars MA-WA56-DP25NB Panel 1 ft Dual 25Mars MA-WA55-27B Panel 1 ft Single 26CommScope UBP600-4-1 Panel 2 ft Single 27.5MTI MT-466010/NVH Panel 2 ft Dual 28General Dynamics EPD2-52 Panel 2 ft Single 28RadioWaves FP2-5-28 Panel 2 ft Single 28MTI MA-QA56-DP28NB Panel 2 ft Dual 28.5MTI MT-486013/NVH Panel 2 ft Dual 29Laird GD5W-25P Grid Parabolic Dish 2 ft Single 25Laird GD53-25  Grid Parabolic Dish 2 ft Single 25Laird GD57-25  Grid Parabolic Dish 2 ft Single 25Laird HDGD58-26  Grid Parabolic Dish 2 ft Single 26Laird GD58-26  Grid Parabolic Dish 2 ft Single 26Commscope 28T-5801-1  Grid Parabolic Dish 3 ft Single 27
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 992013-02-22Laird GD53-28  Grid Parabolic Dish 3 ft Single 28Laird GD57-28 Grid Parabolic Dish 3 ft Single 28Laird GD5W-28P Grid Parabolic Dish 3 ft Single 28CommScope   UBG600-4-1   Grid Parabolic Dish 3 ft Single   28.5Laird GD58-29  Grid Parabolic Dish 3 ft Single 29Laird HDGD58-29  Grid Parabolic Dish 3 ft Single 29RadioWaves G3-5.2 Grid Parabolic Dish 3 ft Single 31.1Wireless Beehive 5.8DP-26  Solid Parabolic 1.5 ft Dual 26PC Tel MPRC2449  Solid Parabolic 2 ft Single 27.7L-Com HG4958DP-30D Solid Parabolic 2 ft Dual 28General Dynamics HQFD2-52 Solid Parabolic 2 ft Dual 28.1PC Tel MPRD2449  Solid Parabolic 2 ft Dual 28.1General Dynamics QFD2-52 Solid Parabolic 2 ft Dual 28.4General Dynamics HQF2-52 Solid Parabolic 2 ft Single 28.5General Dynamics QF2-52 Solid Parabolic 2 ft Single 28.5L-Com HG5158DP-29D Solid Parabolic 2 ft Dual 28.5RadioWaves HPD2-5.2 Solid Parabolic 2 ft Dual 28.6CommScope HPX2F-52 Solid Parabolic 2 ft Dual 29Laird HDDA5W-29-DP Solid Parabolic 2 ft Dual 29Laird HDDA5W-29-SP Solid Parabolic 2 ft Single 29RadioWaves SPD2-5.2 Solid Parabolic 2 ft Dual 29RadioWaves SP2-5.2 Solid Parabolic 2 ft Single 29Wireless Beehive 5.8DP-29 Solid Parabolic 2 ft Dual 29CommScope P2F-57W Solid Parabolic 2 ft Single 29.3CommScope P2F-52 Solid Parabolic 2 ft Single 29.4CommScope PX2F-52 Solid Parabolic 2 ft Dual 29.4ARC Wireless DA5830SD1  Solid Parabolic 2 ft Dual 30Table 7  5GHz AntennasManufacturer Model Number Type Size/Diameter Polarization Gain (dBi)
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios100 203591-0112013-02-22PC Tel MPRC3649 Solid Parabolic 3 ft Single 30.4L-Com HG4958DP-34D Solid Parabolic 3 ft Dual 31PC Tel MPRD3649  Solid Parabolic 3 ft Dual 31Wireless Beehive 5.8DP-31  Solid Parabolic 3 ft Dual 31General Dynamics QFD2.5-52 Solid Parabolic 2.5 ft Dual 31.1General Dynamics QF2.5-52 Solid Parabolic 2.5 ft Single 31.1RadioWaves HPD3-5.2 Solid Parabolic 3 ft Dual 31.1General Dynamics HQFD2.5-52 Solid Parabolic 2.5 ft Dual 31.2RadioWaves HP2-5.2 Solid Parabolic 2 ft Single 31.4RFS Cablewave SPF3-52CN1S Solid Parabolic 3 ft Single 31.4Laird HDDA5W-32 Solid Parabolic 3 ft Single 32Laird HDDA5W-32-DP Solid Parabolic 3 ft Dual 32L-Com HG5158DP-32D Solid Parabolic 3 ft Dual 32RadioWaves SPD3-5.2 Solid Parabolic 3 ft Dual 32.5RadioWaves HP3-5.2 Solid Parabolic 3 ft Single 32.5RadioWaves SP3-5.2 Solid Parabolic 3 ft Single 32.5CommScope PX3F-52 Solid Parabolic 3 ft Dual 33.4CommScope P3F-52 Solid Parabolic 3 ft Single 33.5RFS Cablewave SDF4-52BN1S1 Solid Parabolic 4 ft Single 33.9General Dynamics QFD4-52 Solid Parabolic 4 ft Dual 34.1General Dynamics SSP4-2357A Solid Parabolic 4 ft Single 34.4RFS Cablewave SPF4-52CN1S1R  Solid Parabolic 4 ft Single 34.4CommScope HPX4F-52 Solid Parabolic 4 ft Dual 34.5General Dynamics   HQF4-52   Solid Parabolic 4 ft   Single   34.7General Dynamics HQFD4-52 Solid Parabolic 4 ft Dual 34.8General Dynamics QF4-52 Solid Parabolic 4 ft Single 34.8RadioWaves HPD4-5.2 Solid Parabolic 4 ft Dual 34.8Table 7  5GHz AntennasManufacturer Model Number Type Size/Diameter Polarization Gain (dBi)
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1012013-02-22CommScope P4F-52 Solid Parabolic 4 ft Single 34.9CommScope PX4F-52 Solid Parabolic 4 ft Dual 34.9RadioWaves SP4-5.2 Solid Parabolic 4 ft Single 34.9RadioWaves SPD4-5.2 Solid Parabolic 4 ft Dual 34.9RadioWaves HP4-5.2 Solid Parabolic 4 ft Single 34.9RFS Cablewave DA4-W57BC1S1  Solid Parabolic 4 ft Single 35.5RadioWaves SP6-57 Solid Parabolic 6 ft Single 35.8General Dynamics QFD6-52 Solid Parabolic 6 ft Dual 37.4CommScope P6F-52 Solid Parabolic 6 ft Single 37.6CommScope   PX6F-52   Solid Parabolic 6 ft   Dual 37.6General Dynamics HQFD6-52 Solid Parabolic 6 ft Dual 37.8General Dynamics QF6-52 Solid Parabolic 6 ft Single 37.8CommScope PARX6-59 Solid Parabolic 6 ft Dual 37.9RadioWaves HP6-5.2 Solid Parabolic 6 ft Single 37.9RadioWaves HPD6-5.2 Solid Parabolic 6 ft Dual 37.9RadioWaves SP6-5.2 Solid Parabolic 6 ft Single 37.9RadioWaves SPD6-5.2 Solid Parabolic 6 ft Dual 37.9Table 7  5GHz AntennasManufacturer Model Number Type Size/Diameter Polarization Gain (dBi)
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios102 203591-0112013-02-22TroubleshootingThis section provides information regarding troubleshooting of common issues and alarms on these radios. Exalt Digital Microwave Radio systems are designed by Exalt’s expert engineers with extensive experience through multiple generations of microwave radio design. These new-generation systems contain extensive diagnostic tools, alarm indications, and troubleshooting aids. And, as compared to other systems in their class, are easier to install, maintain, and troubleshoot. The GUI provides information to aid in troubleshooting (see Diagnostic Charts Page).Contact Exalt Customer Care for further assistance with issues with your Exalt radio and with suggestions on how the radio and documentation can be improved.General PracticesTroubleshooting a microwave radio link can be a complex task. Approach troubleshooting as a process of elimination, and first determine which portions of the system are operating properly.In a vast majority of cases, failures or poor performance of microwave links is attributed to something other than the microwave radio hardware. In this respect, the back-to-back bench test (see Back-to-back Bench Testing) is very important to determine if radio hardware is operating properly and eliminate many variables in the troubleshooting process.If a back-to-back bench test fails, then the radio hardware is either broken or the radios are improperly configured. Upgrade the radio to the most current release of firmware, and/or reset the radio to its critical factory settings, following the quick start guide instructions and those in Configuration and Management, helps to confirm if configuration issues cause failure. The most common issues with microwave radio links are:•An improperly terminated RF cable•Multipath propagation•RF interference•Path obstruction•Misaligned antenna•Faulty antenna•Improper grounding•Insufficient link margin in the design/implementation•Moisture in the transmission system (antenna feed and/or RF cable)If the radio link has been operating without issues and is exhibiting new poor performance behavior or becomes completely inoperative, the troubleshooting process should pay close attention to any conditions that may have changed between the time when the system was working without issue and the time when the issues started. Also, it can be helpful to compare some performance parameters of the system before and after the presence of issues. Often the source of the issues can be determined by thoughtful consideration of changes, such as:•Changes in weather, including high winds•Changes made to the radio equipment, transmission system, or connected equipment•New radio systems or electronic equipment the nearby radio or transmission system
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1032013-02-22•New construction nearby either end of the link, or along the path•Tree growth, flooded fields, or changes in rivers/lakes along the pathVerify that configurations are set as follows:•RF matches at each end of the link•Bandwidth matches at each end of the link•Link distance matches at each end of the link•TDD Frame Length matches at each end of the link•Endpoint Identifier is different at each end of the link (one end Radio A, one end Radio B)•Ethernet interfaces are enabled, as desired•AUX Ethernet is set for in-band or out-of-band NMS, as desired•T1/E1 enabling matches at each end of the link•Link security key matches at each end of the linkAlso, use the ExaltCalc tool in the design phase to determine the optimum setting for the Bandwidth and TDD Frame Length parameters for the given link distance, and provides guidance to the expected RF link performance, as well as throughput, latency, and number of supported T1/E1 circuits.Typical Indications of IssuesIn many cases, microwave radio users do not notice changes or degradation to the radio system until the radio system fails completely or becomes highly errored or significantly intermittent. However, regular management of the radio system can help indicate changes in performance that have not yet impacted user performance, but may impact performance at a later date if left unchecked or unaddressed. The administrator can use this as an opportunity to be proactive and monitor the radio link performance regularly, watching for unexplained or unexpected changes in performance and trends in performance changes.Most importantly, monitoring radio system RSL over time indicates the performance of the radio system. Address any long-term drop in RSL and erratic or unsteady RSL. Some RSL changes are expected and weather patterns and the related multipath can cause dramatic RSL changes resulting in system outage. However, that outage should not occur at a significantly greater rate than the designed long-term performance. Consult the path design engineer for more information about link reliability expectations and anticipated RSL deviation.In addition, regular inspection of the transmission system (RF cables and antennas) and paying close attention to changes along the path, such as construction or tree height, or new microwave radio installations nearby, can be extremely helpful and proactive.When link performance is very poor, alarms on the radio front panel and within the radio’s management system indicates particular failures. Consult this manual for more information on the specific alarms and diagnostics, or contact Exalt Customer Care for assistance. Exalt Customer Care is primarily motivated to determine if the radio hardware is faulty and require return for repair, and to help execute an effective and efficient repair and return process for radio terminals believed to be faulty. However, Exalt Customer Care provides advice regarding the total radio system and RF path engineering and environment, and advises on troubleshooting. End users should first contact the installer and/or designer of the system. In many cases, an in-depth understanding of RF design is required, and on-site analysis and special test equipment, may be
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios104 203591-0112013-02-22necessary. Compared to phone support from Exalt Customer Care, troubleshooting is much more expeditious if the professional installer and/or link designer examines the system and reviews the management information in the GUI. In turn, if the professional installer and/or link designer contacts Exalt Customer Care, the process to rectify the system is much more expedient due to the in-depth knowledge related to the implementation and the RF environment.Improper RF Cable TerminationImproper RF cable termination is a very common problem. In many cases, this is a problem that occurs during installation and is not a problem that suddenly appears. However, if cables are moved or flexed, especially near the termination points, and radio errors, changes in RSL, or other performance issues occur, this is a certain sign of this issue. Another relatively easy method to test for this condition is to decrease the output power of the radio system (at each end, one end at a time). A poor RF cable termination may be reflecting too much RF energy back into the radio system, and reducing output power reduces the reflected energy at a faster rate than the transmitted energy towards the far end. Be careful not to reduce the output power to the point where the radio’s threshold is reached. Typically, a reduction of just 3 to 6dB is enough to determine if this is the issue. If the reduction of output power clears the error condition, this is the likely cause.Use a reflectometer or meter that can read VSWR at the operating frequency to identify poor terminations as well as poor antenna feeds.Multipath PropagationMultipath propagation is a term that encompasses changes to the RF path, such as reflections and/or refraction, causing partial or complete destruction of the radio signal, and thus excessive bit errors and/or system outages. Rapid changes in temperature, inversion layers, humidity, air pressure, water evaporation, as well as standing water or moisture on objects along the path are all examples of changes that can cause multipath propagation. New building construction near either end of the path or along the path can cause new reflection characteristics.If your system has been operating without issue and is suddenly experiencing issues that are symptomatic of a certain time of day or related to change in climatic events or some of the external factors listed above, this is likely the cause. Consult a professional RF path engineer in these cases. Often, minor repositioning of the antennas at either or both ends can reduce or eliminate these problems.RF InterferenceRF interference is usually indicative of another radio system nearby either end of your radio system or aimed towards one or both ends of your radio system – usually at or near the same frequency and usually with a similar signal level.Other forms of RF interference also exist, such as electronic equipment placed close to the radio chassis or transmitters that couple onto the cabling or grounding system of the radio. Microwave ovens and wireless communication devices used near the equipment or cabling are examples of electronic equipment interference.Note: The Praxsym VSWR meter is an excellent tool for this purpose.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1052013-02-22RF interference, like most other causes of problems, is indicated by significant bit errors and/or system outages.One means to determine presence of interference is the use of a spectrum analyzer that covers the same range as the radio system. A professional RF engineer can use a spectrum analyzer to locate sources of interference, measure these sources, and determine potential remedies to take to operate in the presence of interference.If a spectrum analyzer is not available, the radio’s RSL port can help determine RSL levels of interfering signals. By turning the far-end radio off, the residual RSL measured by the radio indicates the level of interference seen by the radio. It is possible that interference levels below that which can be measured still have an impact on the radio system – especially if the radio system has low fade margin or is using a high order modulation. Exalt Digital Microwave Radios provides considerable flexibility to tune to different frequencies across the bands within which they operate. This is the easiest method to use to try to avoid existing interference. In addition, the occupied bandwidth of the radio can be reduced. This, along with re-tuning, can be very effective, however throughput is reduced.Repositioning the antenna and/or changing polarization, or upgrading the antenna to a higher gain, and/or using a high-performance antenna, are all secondary means that can be used. It may be necessary to perform combinations of both radio changes (retuning, occupied bandwidth reduction) and antenna system changes (position, polarization, upgrade).Path ObstructionA path obstruction is defined as an object, such as a building or tree, impeding the proper path of the radio system. If the system design was proper at the time of installation and issues arise at a later date, an updated path profile and survey may be necessary to identify changes in path clearance.Misaligned AntennaAt the time of initial installation, it is critical that the antennas at each end are properly aligned and that the designed RSL is achieved. However, antennas may become misaligned due to high winds, changes in the guy-wiring systems keeping the antenna mast stable, or loosening of the antenna mounting hardware. A reduction in the RSL of the link is symptomatic of this condition, but this condition is not the only condition that results in a reduction of RSL. However, if conditions occur where the antenna alignment may be suspected, the mechanics must be inspected and the antennas realigned.Faulty Antenna (connectorized antenna rc-models only)A faulty antenna is rare, but is still a possibility. In some cases, the mechanics of the antenna feed can get moisture inside, or a bad or weak connection in the pin and connector structure of the antenna may occur. A VSWR measurement of the antenna connection can be made to verify this condition. Improper GroundingIn addition to being a potential human safety issue, improper system grounding is a somewhat common condition that can cause continuous bit errors or bit errors when metal objects come in Note: Exalt Digital Microwave Radios operate in license-exempt bands. Microwave ovens, wireless Internet devices and cordless phone technology may also use this frequency band. It may be necessary to separate the radio chassis, cabling system and antenna from these devices.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios106 203591-0112013-02-22contact with the radio, transmission system, or racking system. If touching the radio causes errors, grounding is the cause. It can be difficult to identify grounding problems, but a professional electrician can normally inspect a system and identify if there are deficiencies in the grounding system.Insufficient Link MarginIdeally, the link was designed with enough link margin (fade margin) to allow for multipath propagation and atmospheric fading and still remain reliable. In some cases, link margin is compromised by economic factors, such as using low-cost RF cabling or lower-cost antennas that have less gain or deficient performance compared to higher cost transmission system components. In some cases, there may be antenna size restrictions that forced the design to not have the desired amount of link margin.If the link was designed with poor link margin, there are likely many cases of bit errors and outages. The antenna system and transmission line can be upgraded to help reduce this. If the link design was installed with sufficient margin, but RSL is reduced, the remaining link margin may no longer be enough to maintain a reliable link. The causes of RSL reduction were previously described, but are usually due to new path obstruction(s) or antenna misalignment due to wind or mechanical factors. The antenna height or location can be changed to overcome new obstructions. Realignment of the antenna, and/or improvement to mechanical structures can help overcome antenna misalignment.Moisture in the Transmission SystemIf the connectors on cables and antennas and egress junctions are not properly weatherproofed, moisture can get into the transmission system and cause significant error conditions and erratic performance. In many cases, the transmission system must be replaced. A VSWR meter is one means to identify such issues. Conduct physical inspections often. If changes to the weatherproofing (such as cracking) are noticed, replace the weatherproofing before leakage occurs.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1072013-02-22Back-to-back Bench TestingUse back-to-back bench testing to test the radio before installation, pre-configure the radio and connected equipment before installation, or in the troubleshooting process to identify if the radio hardware is the source of a system issue. It is a critical process, and often required or highly desirable for any installation or troubleshooting exercise. This section describes how to properly configure the radio hardware and accessories for a proper back-to-back bench test.For radio testing, there are two types of back-to-back configurations:1Basic test (test general operation)2Specification performance verificationBasic TestThe basic test is a simple test of radio functionality. It verifies that the radios are properly configured to communicate to one another, and verifies general radio performance as operational.For the basic test, the following items are needed:•Radio pair•Powering source•RF interconnect cable(s) (any length – short is best)•Fixed or variable attenuation, between 60 and 90dB (note: attenuation for basic test does not to be calibrated or precise)•Computer/terminal with either serial or Ethernet port (helpful, but not necessary)– If no computer is available, use the temporary hardware configuration key or DIP switch, depending on radio model (see Initial Configuration and Back-to-Back Bench Test)Connect the items as follows:1Connect attenuation and (known-good) RF cable(s) between radio pair, shown in Figure 59.2Configure one radio as Radio A; the other as Radio B3Power on radio pairFigure 59   Basic back-to-back bench test configurationAfter connecting and powering on, observe the front panel LEDs to verify that the LINK and STATUS LEDs are green. If so, the radios are communicating and all radio-related alarm conditions are normal.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios108 203591-0112013-02-22It can be beneficial to have a computer to verify configuration in case of red LEDs or to pre-configure the radio as desired for operation. Follow the instructions in Configuration and Management.Specification Performance VerificationThe specification performance verification is a more detailed test that allows you to verify that the radio’s output power and threshold specifications are being met. This is typically a test that would only be performed in a troubleshooting scenario, but can be performed before installation to provide a detailed record or ensure radio performance before installation.This test is identical to the basic test, but in place of the fixed attenuation, it requires the use of calibrated variable attenuation, or a set of calibrated fixed attenuators, or a combination of both, adding to a total attenuation value of 120dB, as measured at the operating frequency of the radio. In addition, a volt meter or computer is also required. Connect the system as shown in Figure 59, using the combination of fixed and variable attenuation between the radio’s RF ports. Connect the volt meter to either radio’s RSL test point and associated reference ground connection.In this test, it is desirable to use pre-tested RF cables, known to be good, and the insertion loss is known at the operating frequency. If the cables are short (6'/2m or less), you can estimate the loss, including connectors, to be less than 1dB each. The estimate of cable loss is critical to the overall confidence of the measurements made in this test.There are two critical specifications that can be tested in this configuration:•RF output power•Radio receiver thresholdTo measure transmitter output power, simply insert any value of attenuation between the radios between 60 and 90dB. Ensure that both RF output power settings are at maximum. Use the volt meter to measure RSL in both directions. The RSL measured value should match the appropriate value according to the inserted attenuation, such as:RSL = RF Output Power – cabling losses – total attenuationVerify output power by adjusting output power using the Exalt GUI (in administration mode) and evaluate the corresponding change to the RSL measurement.For threshold testing, the key is to insert a measured amount of loss that is close to, but not exceeding the radio’s specified system gain. System gain is the difference between RF output power and receiver threshold. At your selected modulation and bandwidth settings, determine the specified threshold performance, and choose a value of attenuation (including cable losses) that adds to roughly 5 to 15dB less than the system gain. For example, if the threshold for your measurement is -85dBm, the output power is +27dBm, so the system gain is 112dB. Choose a value of total attenuation in the range of roughly 100–105dB. Once this attenuation is inserted, verify RSL readings as in the first step, and then, using the GUI, reduce radio output power in 1dB steps until the receiving radio (the one whose output power not being adjusted) Link LED turns from green to yellow. This indicates that threshold has been reached. At this point, verify the equation for system gain using the new output power level setting and verify that the threshold performance is meeting or exceeding the published specification. Note: Due to the variation of measurements and accuracies involved in this test, you may read a measurement that is 1dB to as much as 2dB off of the expected value. It should be of no concern unless the value is more than 3dB worse than expected.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1092013-02-22General Compliance and SafetyThe usage of radio transmission devices is subject to specific regulatory requirements governed by regional legislation. In most cases, the specific device must be authorized for use in a given country and must be installed and adjusted in accordance with specific radio-frequency settings and in a manner that has been authorized specific to the device itself in accordance with the specific location of the device. Some users may be completely or partially restricted from use of the device. Please consult local governmental agency/agencies for regulatory requirements before use, or contact Exalt or your Exalt authorized dealer for assistance.Do not modify this device in any way without the express written consent of Exalt. Modification voids the manufacturer warranty, and may also be illegal in accordance to government regulations. In addition, there are no user-serviceable parts or assemblies inside the product housing. There may also be voltages, signals, and mechanisms within the device that could be harmful to human safety.The mounting of this device and associated peripherals and connections (inclusive of antenna mast, antenna, cabling, egress, lightning protection devices, grounding, power, and so on) may be subject to regional requirements for health and human safety. A qualified professional installer and an electrician are highly recommended, and may be required by law.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios110 203591-0112013-02-22Dynamic Frequency SelectionDynamic Frequency Selection (DFS) may be required by regional regulation in some frequency bands to avoid causing interference to radar systems. Prior to the start of any transmission, devices equipped with DFS monitor the spectrum and are not permitted to transmit on any frequency in use for radar transmissions for a period of 30 minutes, during which time the frequency will not be available and the link will be dropped.During operation of the device, the spectrum is continually monitored by DFS to detect radar transmissions on the operating frequency. If radar transmissions are detected, the device must drop the channel within a specified time period so as not to cause interference with the radar transmission. Devices equipped with DFS are required to stay off that part of the spectrum for a minimum of 30 minutes, after which time the device may then re-check the spectrum for radar transmissions and begin transmitting if no radar is detected.Enable Automatic Channel Switching to automate a search for frequencies without radar interference. Note that DFS adds a one-minute wait time per channel switch. See Automatic Channel Selection (ACS) Page.The FCC (the Commission), NTIA, FAA, and industry are working to resolve interference to Terminal Doppler Weather Radar (TDWR) systems used near airports that occurs from some outdoor wireless systems operating in the 5470–5725 MHz band. These wireless devices are subject to Section 15.407 of FCC rules: When operating as a master device they must implement radar detection and DFS functions. The Commission is continuing to develop long-term equipment authorization test procedures to ensure that the devices comply, including protecting TDWR operations. In the interim, the Commission now allows wireless master-device certification with radar detection function and with DFS capability when meeting the following conditions: •Devices must not transmit on channels overlapping the 5600–5650 MHz band.1 •Devices intended for outdoor use must be further restricted, as follows: – Must be professionally installed when operating in the 5470–5725 MHz band.2– Grantees must provide owners, operators, and all such installers with specific instructions in their user’s manual on requirements to avoid interference to TDWRs, and information that meets the following instructions: –Any installation of either a master or a client device within 35km of a TDWR location shall be separated by at least 30 MHz (center-to-center) from the TDWR operating frequency (a table of locations can be obtained from the FCC on page 3 of document 443999) 3, 4, 5, and –Procedures for installers and operators on how to register the devices in the industry-sponsored database with the appropriate information regarding the location and operation of the device and installer information is included.6 Note: When DFS is enabled, the radio temporarily stops transmitting for at least 60 seconds to ensure that no radar interference is present. This is called Channel Availability Check (CAC). The DFS status displays on the Alarms Page. Once CAC passes, the radio resumes normal operation. If at any time during CAC or regular operation a qualifying radar signature is detected, the radio shuts down communications for a minimum of 30 minutes. This is the Non-Occupancy Period (NOP). Transmission only resumes after the NOP completes and then only after a successful CAC.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1112013-02-22Notes:1The devices subject to these requirements can select the initial channel for operation to avoid TDWRs and apply the Uniform Channel Spreading requirements (see FCC 06-96 in ET Docket 03-122 released June 30, 2006) on the remaining available frequency band of operation. All the other test procedures including the test radar patterns remain the same at the present time. A revision to the measurement procedure with modification to the Uniform Channel Spreading requirement and other changes will be released in the future. The Commission will also address the issue of any field upgrade option at that time. 2The grantee must identify the specific expertise and the training required by the installers for installing these types of devices. 3In some instances it is possible that a device may be within 35km of multiple TDWRs. In this case the device must ensure that it avoids operation within 30 MHz for each of the TDWRs. This requirement applies even if the master is outside the 35km radius but communicates with outdoor clients which may be within the 35km radius of the TDWRs. 4The requirement for ensuring 30 MHz frequency separation is based on the best information available to date. If interference is not eliminated, a distance limitation based on line-of-sight from TDWR must be used. In addition, devices with bandwidths greater than 20 MHz may require greater frequency separation. 5Devices may be optionally designed not to transmit on channels which overlap 5570–5680 MHz instead of requiring installers to perform site-by-site adjustments. In that case it is still required that the devices should be installed professionally and the procedures for registering the device in the industry database should be included in the users manual. 6A voluntary WISPA-sponsored database allows operators and installers to register the location information of the UNII devices operating outdoors in the 5470–5725 MHz band within 35km of any TDWR location (see http://www.spectrumbridge.com/udia/home.aspx). This database may be used by government agencies to expedite resolution of any interference to TDWRs.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios112 203591-0112013-02-22Safety Notices1Review this entire guide for important installation instructions BEFORE attempting to install this product.2This product is intended to be installed, used, and maintained by experienced telecommunications personnel only.3Employ a properly licensed or authorized electrician to install or evaluate/certify the installation of all power and grounding related to the use of this equipment and all connected devices.4The device(s) shall only be connected to AC power sources provided by the supplier or to DC sources within the device specifications. Use a separate breaker circuit at the power source.5Lightning, surge protection devices, and earth grounding are required for most installations to ensure human safety. Consult a qualified electrician.6Servicing of this device should be performed by authorized personnel only. Do not disassemble this device. By opening or removing any covers you may expose yourself to hazardous energy parts. Incorrect reassembly of this product can cause a malfunction, and/or electrical shock, when the unit is subsequently used.7Do not connect or disconnect the power connection to the device when the power supply is plugged into an AC outlet. To connect, first connect the power connection to the device, and then apply power (or plug in) at the outlet. To disconnect, disengage power at the outlet or unplug, and then disconnect the direct connection to the device.8Do not insert any object of any shape or size inside this product at any time, whether powered or not. Objects may contact hazardous energy components that could result in a risk of fire or personal injury.9Liquids shall not come in contact with, or enter the inside of the device at any time.10 Proper ventilation and/or airflow shall be provided surrounding the equipment. Items shall not come in contact with heat-sinking materials. Ensure that ambient operational and storage temperature specifications are maintained at all times.11 Equipment is suitable for mounting on noncombustible surfaces only.12 Do not move or alter the marking labels.13 A CSU or similar isolating device is necessary between the equipment and the public telecommunications network. The equipment has not been evaluated for direct connection to the public telecommunications network.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1132013-02-22Regulatory Notices49xx ModelsThe ExtendAir (TDD) 49xx models are licensed-band products operating within Part 90 of the FCC regulations and RSS-111 of Industry Canada. These bands are specifically reserved for Public Safety applications and related agencies, in accordance with these regulations.Transmitter power reduction may be required, depending on transmission system gains and losses, in accordance with instructions found in this appendix. The transmitter power of the device must be reduced by 1 dB for every 1 dB that the antenna gain exceeds 26 dBi (inclusive of transmission system losses).United States ComplianceThe ExtendAir (TDD) Series 50xx models operate under FCC Rule Parts 15.247 and/or 15.407 as a license-exempt device. They may only be used as a point-to-point transmission device for fixed or temporary-fixed (non-mobile) installations. The devices are subject to the following restrictions:•Do not use external amplifiers to boost the power or overcome transmission system losses, unless the specific amplifier/cable/antenna combination has expressly been authorized by the FCC. The output power must never exceed +30 dBm.•Cross-border transmissions are expressly prohibited, except with written permission from both the FCC and the governing body of the neighboring country (Cofetel for Mexico; Industry Canada for Canada).•Use only parabolic dish antennas or directional flat-panel antennas. No other types of antennas (omni-directional, yagi, and so on) are authorized. Parabolic dishes of either grid or solid type are allowed. Maximum mid-band gain of each type of antenna certified is:– Parabolic dish: 37.9 dBi (6'/1.8m diameter)– Directional flat panel: 28 dBi (~2'/61cm square)Federal Communications Commission (FCC), United StatesThe device is allowed to be used provided it does not cause interference to other devices. It is not guaranteed to provide protection against interference from other electronic and radio devices.The system has been tested and found to comply with the limits of a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:•Reorient or relocate the receiving antenna.•Increase the separation between the equipment and receiver.•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•Consult the dealer or an experienced radio/TV technician for help.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios114 203591-0112013-02-22Shielded cables and I/O cords must be used for this equipment to comply with the relevant FCC regulations.Changes or modifications not expressly approved in writing by Exalt may void the user’s authority to operate this equipment.This device must be professionally installed.To comply with regulations, the output power of this device may need to be adjusted in accordance to the associated transmission system. See RF Output Power Setting for details.The antenna associated with this device shall be mounted in a location that is at least 10.5'/3.2m away from humans that may be subject to long-term or continuous exposure.Canada ComplianceThe ExtendAir (TDD) Series 50xx models operate under RSS-210 of Industry Canada regulations. Operation is subject to the following conditions, unless express permission is granted by Industry Canada to operate in a different manner:•External amplifiers cannot be used to boost the power or to overcome transmission system losses, unless the specific amplifier/cable/antenna combination is expressly authorized by Industry Canada.•Cross-border transmissions are expressly prohibited, except with written permission from both Industry Canada and the governing body of the neighboring country (FCC for USA)•Only parabolic dish antennas or directional flat-panel antennas may be used. No other types of antennas (omni-directional, yagi, and so on) are authorized. Parabolic dishes of either grid or solid type are allowed. Maximum gain of each type of antenna allowed is:– Parabolic dish: 37.9 dBi (6'/1.8m diameter)– Directional flat panel: 28 dBi (~2'/61cm square)Industry Canada (IC), CanadaThis Class B Digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numerique de la classe B respecte les exigences du Reglement sur le material broilleur du Canada.This device complies with RSS-210 of Industry Canada. Operation is subject to the following two conditions:1this device may not cause interference, and2this device must accept any interference, including interference that may cause undesired operation of the device.Antennas Supported in CanadaThe ExtendAir (TDD) Series 50xx models are designed to operate with the antennas listed in Table 7, which have a maximum gain of 37.5dBi. Antennas not included in the list or having a gain greater than 37.5dBi are strictly prohibited for use with this device. The required antenna impedance is 50 Ohms.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1152013-02-22Europe and ITU Country ComplianceAll of these permitted devices must be professionally installed. They can only be used as a point-to-point transmission device for fixed or temporary-fixed (non-mobile) installations.The ExtendAir (TDD) Series 50xx models operate under EN 301 893 and EN 302 502 rules as a license-exempt device. The ExtendAir (TDD) Series 50xx models comply with ETS 301 893 for the 5.3 and 5.47 GHz bands for license-exempt use for most countries recognizing ETSI or ITU band assignments. This band is not yet harmonized for all countries recognizing ETSI or ITU band assignments. These bands require Dynamic Frequency Selection (DFS) and Transmitter Power Control (TPC) for radar-detection and avoidance. There is a +30dBm EIRP limit applied to this band. Transmitter power must be adjusted accordingly with respect to the RF cabling losses and antenna gains associated with each terminal.The ExtendAir (TDD) Series 50xx models comply with ETS 302 502 for the 5.8 GHz band. This band is not yet harmonized for all countries recognizing ETSI or ITU band assignments. Consult the individual country regulations or your Exalt Communications representative for details. This band requires DFS and TPC for radar-detection and avoidance. There is a +33dBm EIRP limit for use of the 10 MHz BW setting, and a +36dBm EIRP limit for use of the 20 MHz BW setting. Some countries limit the EIRP to +5dBm for all bandwidths in this band.All models comply with the requirements for CE Mark (EN 60950-1 and IEC 60950-1) and EMC (EN 301 489-17). No substitutions shall be made, and all wiring and grounding instructions contained in this manual must be followed to ensure safety in accordance to the standards and local rules.Note:  Do not use external amplifiers to boost the power or overcome transmission system losses, unless the specific amplifier/cable/antenna combination has expressly been authorized by the specific country regulations. The output power must never exceed that specified in Specifications.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios116 203591-0112013-02-22Regulatory ComplianceAs of this printing, Exalt Communications, Inc. has approvals for the products that are covered by this manual, as indicated in Table 8. If your application or country is not listed, check with your Sales Representative for the current status.Notations are as follows: indicates approved; () indicates in-process; * indicates consult Exalt Communications for availability.Table 8  Product Approvals (Exalt)Country 4.9GHz 5.3GHz 5.4GHz 5.8GHzAustria * Australia Belgium Brazil Bulgaria * Canada ()()Cyprus * *Czech Republic * *Denmark * *Estonia * *Finland * France * Germany * *Great Britain * *Greece * *Hungary * Iceland * *Ireland * *Italy * *Latvia * Liechtenstein *Lithuania * *Luxembourg Malta *Mexico  *
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1172013-02-22Netherlands * *Norway * *Philippines * * *Poland * *Portugal * *Romania * *Slovak Republic * *Slovenia * *Spain * *Sweden * *Switzerland *Thailand * * *UAE * * *United States ()()Table 8  Product Approvals (Exalt) (Continued)Country 4.9GHz 5.3GHz 5.4GHz 5.8GHz
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios118 203591-0112013-02-22EIRP Limits for the United States and CanadaEIRP for the USA and Canada4940–4990 MHz BandFor the ExtendAir (TDD) Series 4.9xx models, within the 4940–4990 MHz band, the maximum EIRP allowed is +50dBm. The maximum output power of the radio shall never exceed +24dBm.The transmit power must be reduced from maximum (+24dBm for 20MHz BW; +22dBm for 10MHz) by 1 dB for every 1dB that the antenna gain exceeds 26dBi (including transmission system losses)5250–5350 MHz and 5470–5725 MHz BandsFor 5250–5350 MHz and 5470–5725 MHz bands, the maximum EIRP is based on the bandwidth selection of the radio. The maximum output of the radio is +22 dBm.P ≤ EIRP – G + Lwhere:5725–5850 MHz BandFor all models within the 5725–5850 MHz band, the maximum output power of the radio is +22 dBm. The radio may operate at full power into the maximum gain antenna specified, which is 37.9dBi.Note:  The professional installer is responsible to ensure that RF output power is properly adjusted to not exceed the regulatory limit.P = Maximum transmitter output power of radio, in dBm.EIRP = 26.38 (for 8MHz BW selection), 29.41 (for 16MHz BW selection), or 30 (for 32MHz BW selection)G = Specified gain of antenna, in dBi, at the operating frequency.L = Total transmission system losses of all elements between the radio’s RF connector and the antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified or measured between at the operating frequency.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1192013-02-22EIRP Limits for Australia5470–5725 MHz BandFor ExtendAir (TDD) Series 50xx models within the 5470–5725 MHz band, the maximum EIRP allowed is 30 dBm.  The maximum output power of the radio is +22 dBm. P = 30 – G + Lwhere:5725–5850 MHz BandFor ExtendAir (TDD) Series 50xx models within the 5725–5850 MHz band, the maximum EIRP allowed is 36 dBm. The maximum output power of the radio is +22 dBm.P = 36 – G + Lwhere:Note:  The professional installer is responsible to ensure that RF output power is properly adjusted to not exceed the regulatory limit.Note:  Australian regulations have a no-transmit band from 5600–5650 MHz, adjust the transmitter to avoid this range.P = Maximum transmitter output power of radio, in dBm.G = Specified gain of antenna, in dBi, from 5470 to 5725 MHz.L = Total transmission system losses of all elements between the radio’s RF connector and the antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified or measured between 5470 and 5725 MHz.P = Maximum transmitter output power of radio, in dBm.G = Specified gain of antenna, in dBi, from 5725 to 5850 MHz.L = Total transmission system losses of all elements between the radio’s RF connector and the antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified or measured between 5725 and 5850 MHz.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios120 203591-0112013-02-22EIRP Limits for the European Union and ITU CountriesThe countries that are covered by this Regulatory Domain are:  Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Ghana, Great Britain, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Norway, Poland, Portugal, Slovak Republic, Slovenia, Spain, Sweden, Netherlands, Switzerland, and Turkey.•Use only parabolic dish antennas or directional flat-panel antennas. No other types of antennas (omni-directional, yagi, and so on) are authorized. Parabolic dishes of either grid or solid type are allowed. Maximum mid-band gain of each type of antenna certified is:– Parabolic dish: 37.9 dBi (6'/1.8m diameter)– Directional flat panel: 28 dBi (~2'/61cm square)50xx Series EIRP Table 9 summarizes the maximum power by band and country for ExtendAir (TDD) Series radios. 5250–5350 MHz bandFor all models within the 5250–5350 MHz band, the maximum EIRP is specified in Table 9. The maximum output of the radio is +22 dBm.P = ME – G + Lwhere:5470–5725 MHz bandFor all models within the 5470–5725 MHz band, the maximum EIRP allowed is specified in Table 9. The maximum output power of the radio is +22 dBm. P = ME – G + Lwhere:Note:  The professional installer is responsible to ensure that RF output power is properly adjusted to not exceed the regulatory limit.P = Maximum transmitter output power of radio, in dBm.ME = Maximum EIRP, as specified in Table 9.G = Specified gain of antenna, in dBi, from 5250 to 5350 MHz.L = Total transmission system losses of all elements between the radio’s RF connector and the antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified or measured between 5250 and 5350 MHz.P = Maximum transmitter output power of radio, in dBm.ME = Maximum EIRP, as specified in Table 9.G = Specified gain of antenna, in dBi, from 5470 to 5725 MHz.L = Total transmission system losses of all elements between the radio’s RF connector and the antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified or measured between 5470 and 5725 MHz.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1212013-02-225725–5850 MHz bandFor all models within the 5725–5850 MHz band, the maximum transmit power with respect to specific country EIRP regulations is determined based on the channel bandwidth. The EIRP power limit is specified in Table 9. The ExtendAir (TDD) Series radios maximum transmitter conducted power is +22 dBm. Use the following equation to determine the maximum transmitter power for the radio:P = ME – G + Lwhere:P = Maximum transmitter output power of radio, in dBm.ME = Maximum EIRP, as specified in Table 9.G = Specified gain of antenna, in dBi, from 5725 to 5850 MHz.L = Total transmission system losses of all elements between the radio’s RF connector and the antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified or measured between 5725 and 5850 MHz.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios122 203591-0112013-02-22Table 9  EU and ITU Country Specific EIRP LevelsCountry  Maximum EIRP 5.3 GHz band Maximum EIRP 5.4 GHz bandMaximum EIRP 5.8 GHz band(BW dependent)aa. If the output power is designated as 33/36 dBm, the EIRP is limited to 33 dBm for 10 MHz bandwidthtransmissions and 36 dBm for 20 MHz bandwidth transmissions.Austria 23 dBm 30 dBm 5 dBmBelgium 30 dBmCyprus 23 dBm 30 dBmCzech Republic 23 dBm 30 dBm 33/36 dBmDenmark 23 dBm 30 dBm 33/36 dBmEstonia 23 dBm 30 dBmFinland 23 dBm 30 dBmFrance 23 dBm 30 dBm 33/36 dBmGermany 23 dBm 30 dBm 33/36 dBmGhana 23 dBm 30 dBm 33/36 dBmGreat Britain 23 dBm 30 dBm 33/36 dBmHungary 23 dBm 30 dBm 33/36 dBmIceland 23 dBm 30 dBm 33/36 dBmIreland 23 dBm 30 dBm 33/36 dBmItaly 23 dBm 30 dBm 33/36 dBmLiechtenstein 23 dBm 30 dBm 5 dBmLithuania 23 dBm 30 dBm 33/36 dBmLuxembourg 23 dBm 30 dBmNetherlands 23 dBm 30 dBm 33/36 dBmNorway 23 dBm 30 dBm 33/36 dBmPoland 23 dBm 30 dBm 33/36 dBmPortugal 23 dBm 30 dBm 5 dBmRomania 23 dBm 30 dBm 33/36 dBmSlovak Republic 23 dBm 30 dBm 5 dBmSlovenia 23 dBm 30 dBmSpain 23 dBm 30 dBm 33/36 dBmSweden 23 dBm 30 dBm 33/36 dBmSwitzerland 23 dBm 30 dBm 5 dBmTurkey 23 dBm 30 dBm 33/36 dBm
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1232013-02-22Declaration of Conformity to the R&TTE Directive1999/5/EC For 5 GHz radios, the following standards were applied:•Radio: EN 301 893, EN 302 502•EMC: EN 301 489-1, EN 301 489-17 •Safety: EN 60950-1, IEC 60950-1The following CE mark is affixed to the product:EU WEEEExalt is committed to meeting the requirements of the European Union’s Waste Electrical and Electronic Equipment (WEEE) Directive. The Directives require producers of electrical and electronic equipment to finance the take-back for re-use or recycling of their products placed on the EU market after 13 August 2005. Exalt products that are within the scope of the Directives are labeled with a crossed-out "wheelie-bin" symbol as required by the Directives. This indicates that the product was placed on the market after 13 August 2005 and that end-users should segregate the product from other wastes at end-of-life.The WEEE Directives are being implemented in each of the 28 EU and European Economic Area (EAA) countries through national legislation. This has resulted in considerable variation in the detailed requirements across the EU, many of which require presence in the EU.  As a result, Exalt’s WEEE compliance approach is to require the distributors and/or resellers in the EU to comply with each country’s national legislation by registration of the distributor or reseller as the producer and for the reseller/distributor to carry out and fulfill the legislative requirements of each national compliance scheme.Below is the crossed out wheelie bin symbol as required by the WEEE Directive.English:  This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Deutsch:  Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der Richtlinie1999/5/EU. Dansk:  Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Directiv 1999/5/EF. Español:  Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC. Français:  Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive 1999/5/EC. Íslenska:  Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB. Italiano:  Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC. Nederlands:  Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC. Norsk:  Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv 1999/5/EC. Português: Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC. Suomalainen:  Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen mukainen. Svenska:  Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i Direktiv 1999/5/EC.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios124 203591-0112013-02-22EU RoHSRoHS is the acronym used to refer to the European Union (EU) Directive 2002/95/EC on the Restriction of the use of certain hazardous substances in electrical and electronic equipment.  Hazardous materials are those chemicals and substances that are legislatively, market, or customer banned or restricted for use in products and/or manufacturing.  There are six (6) RoHS substances:  lead (Pb), cadmium (Cd), mercury (Hg), hexavalent chromium (Cr+6), polybrominated biphenyls (PBB) and polybrominated diphenylethers (PBDE).  Other countries may be introducing legislation that results in similar restrictions of hazardous substances.  Many Exalt products will continue to use lead-based solder under the exemption allowed for network infrastructure equipment.  Small amounts of lead, cadmium, mercury, hexavalent chromium, PBB, and PBDE can also be found in a few electrical and electrical components.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1252013-02-22Exalt Limited Hardware Warranty Software License and RMA Procedures AgreementTHIS IS AN AGREEMENT BETWEEN YOU AND EXALT COMMUNICATIONS, INC. ("EXALT").  BY EXECUTING OR OTHERWISE ACCEPTING THIS AGREEMENT OR BY USING THE EXALT PRODUCT WITH OR FOR WHICH THIS AGREEMENT IS PROVIDED ("PRODUCT"), YOU ARE AGREEING TO ALL OF THE BELOW TERMS AND CONDITIONS.  IF YOU DO NOT AGREE WITH THESE TERMS AND CONDITIONS, YOU SHOULD NOT USE THE PRODUCT AND RETURN IT TO YOUR PLACE OF PURCHASE. "YOU" MEANS THE LEGAL (END USER) ENTITY THAT PURCHASED THE PRODUCT.1Exalt Limited Hardware Warranty a. Exalt warrants solely to the original purchaser ("Purchaser") that the Exalt hardware product that this Agreement is provided with or for (the "Hardware Product") will substantially conform in all material respects to the relevant Exalt published specifications that apply at the time of manufacture of such Hardware Product for one (1) year from the date of purchase of Hardware Product by Purchaser (the "Warranty Period").  Purchaser may elect to extend the Warranty Period by one additional year as set forth below.  Proof-of-purchase in the form of an invoice, payment of invoice, or delivery waybill must be supplied, if requested by Exalt, in case of any dispute of warranty start date. b. In the event Purchaser notifies Exalt during the Warranty Period of a defective Hardware Product (material nonconformance with the published specifications), Exalt shall within the Warranty Period, at its own option either: (A) use reasonable efforts to remedy any reproducible Hardware Product defect covered by this limited warranty within a reasonable period of time; (B) replace the defective Hardware Product with a functionally equivalent product (repair parts and products may be either reconditioned or new, but, if reconditioned, shall be of the same quality as new parts or products); or (C) if Exalt determines that it is unable to repair or replace such Hardware Product, Exalt (or its applicable reseller) will refund to Purchaser the amount actually paid by Purchaser for the applicable Hardware Product.c. All replaced parts become the property of Exalt. Exalt may, at its sole option, refuse to accept as defective any Hardware Product that (i) is subject to the exclusions set forth below; or (ii) cannot be demonstrated to be defective by Exalt and Purchaser is unable to provide adequate information describing how the Hardware Product failed. Such Hardware Product will, at Purchaser's option and expense, either be: (a) returned to Purchaser in the state received, or (b) repaired and returned to Purchaser.  Repaired or replaced Hardware Product will be warranted for the remainder of the original Warranty Period, but not less than ninety (90) days.2Timely Registration May Extend Limited Hardware Warranty Period Purchaser may elect to extend the one (1) year Warranty Period to a two (2) year Warranty Period by registering the Hardware Product with Exalt within ninety (90) days of Hardware Product purchase (all requested registration information must be provided in clear and accurate form within such 90 day period). [Product registration may be performed by completing and submitting the product registration form on www.exaltcom.com/ProductRegistration ]3Limited Hardware Warranty Exclusions This limited warranty will not apply to: (A) any Hardware Product that: (i) has been modified or altered by any party other than Exalt; (ii) has been subject to accident, misuse, abnormal wear and tear, neglect, or mistreatment; (iii) has been damaged during installation of the Hardware Product;
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios126 203591-0112013-02-22(iv) has been damaged by the equipment or system with which the Hardware Product is used; (v) has sustained damage to the Hardware Products' interface or power connectors; (vi) is determined to be stolen; or (vii) has been damaged by fire, power changes, other hazards, or acts of God (including without limitation lightning); or (B) any Software included in any such Hardware Product (see Software License below).  The warranty applies only to Hardware Products that can be identified by the Exalt trademark, trade name, serial number or logo affixed to them.  Exalt does not warrant any Hardware Product that is not manufactured by, for, or with permission from Exalt.  The Hardware Products covered by this warranty are not consumer products and are not intended for personal, family, or household purposes, nor are they intended for high-risk activities as described in Section 5 below. 4Hardware Product RMA ProceduresA return material authorization (RMA) is required prior to returning Hardware Product to Exalt for warranty or out-of-warranty repair/evaluation. As such, Purchaser must use the following procedure: a. Contact Exalt Customer Care, by phone at +1 408-688-0202 or USA Toll-Free at +1 877-EXALT-01 (392-5801), or by e-mail at support@exaltcom.com, and request an RMA number. Please be prepared to provide the serial number of the Hardware Product, the date of purchase, and a description of the failure that is as complete as possible. b. Pack the Hardware Product in its original container and packing or an equivalent.c. Write the RMA number CLEARLY on the outside of the shipping box. d. Cost of shipment to Exalt's authorized service center, taxes, duty, tariffs, risk of loss and insurance charges to Exalt shall be borne by the Purchaser. During the Warranty Period, for service of defects covered by this limited warranty, cost of return shipment and insurance charges shall be borne by Exalt.  For return shipment outside of the U.S., Purchaser shall be responsible for duty, tariffs and any other re-importation costs.  Exalt will select the carrier and method/schedule of shipment. Purchaser may expedite return shipments, upon request, at its own expense. PRODUCTS RETURNED WITHOUT A DULY ISSUED RMA NUMBER WILL BE RETURNED TO PURCHASER AT PURCHASER'S EXPENSE. 5PRODUCT WARRANTY DISCLAIMER AND LIMITATION OF LIABILITYa. THE ABOVE EXPRESS LIMITED WARRANTY FOR THE HARDWARE PRODUCT, THE CONDITIONS AND OTHER TERMS SET FORTH IN THIS AGREEMENT ARE IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS AND OTHER TERMS WHETHER EXPRESS, IMPLIED OR STATUTORY, REGARDING THE PRODUCT (HARDWARE PRODUCT AND SOFTWARE) AND ANY SERVICES PROVIDED BY EXALT, AND EXALT, ITS SUPPLIERS AND LICENSORS HEREBY EXPRESSLY DISCLAIM, TO THE EXTENT ALLOWED BY APPLICABLE LAW,  ANY AND ALL SUCH EXPRESS, IMPLIED AND STATUTORY WARRANTIES, CONDITIONS AND OTHER TERMS, INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, TITLE, INTERFERENCE WITH QUIET ENJOYMENT, NON-INFRINGEMENT OF THIRD-PARTY RIGHTS AND MERCHANTABILITY. FURTHER, EXALT DOES NOT WARRANT RESULTS OF USE OR THAT YOUR USE OF THE PRODUCT WILL BE UNINTERRUPTED OR ERROR FREE. NO WARRANTIES ARE MADE BY EXALT'S SUPPLIERS OR LICENSORS. EXCEPT FOR THE ABOVE EXPRESS LIMITED WARRANTY FOR THE HARDWARE PRODUCT, THE CONDITIONS AND OTHER TERMS STATED HEREIN, THE
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1272013-02-22PRODUCT IS PROVIDED "AS IS" AND WITH ALL FAULTS. THE ENTIRE RISK AS TO SATISFACTORY QUALITY, ACCURACY, AND EFFORT IS WITH YOU. b. THE PRODUCT IS NOT FAULT-TOLERANT AND IS NOT DESIGNED, MANUFACTURED OR INTENDED FOR USE OR RESALE AS ONLINE CONTROL EQUIPMENT IN HAZARDOUS ENVIRONMENTS REQUIRING FAIL-SAFE PERFORMANCE, SUCH AS IN THE OPERATION OF NUCLEAR FACILITIES, AIRCRAFT NAVIGATION OR COMMUNICATION SYSTEMS, AIR TRAFFIC CONTROL, DIRECT LIFE SUPPORT MACHINES OR WEAPONS SYSTEMS, IN WHICH THE FAILURE OF THE PRODUCT COULD LEAD DIRECTLY TO DEATH, PERSONAL INJURY, OR SEVERE PHYSICAL OR ENVIRONMENTAL DAMAGE.  EXALT AND ITS SUPPLIERS AND LICENSORS SPECIFICALLY DISCLAIM ANY EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR ANY HIGH-RISK USES LISTED ABOVE.c. REGARDLESS OF WHETHER ANY REMEDY SET FORTH HEREIN FAILS OF ITS ESSENTIAL PURPOSE OR OTHERWISE, AND TO THE EXTENT ALLOWED BY APPLICABLE LAW, IN NO EVENT WILL EXALT, ITS SUPPLIERS OR LICENSORS BE LIABLE TO YOU OR TO ANY THIRD PARTY UNDER ANY TORT, CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY LOST PROFITS, LOST OR CORRUPTED DATA, COMPUTER FAILURE OR MALFUNCTION, INTERRUPTION OF BUSINESS, OR OTHER SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING OUT OF (1) THE USE OR INABILITY TO USE THE PRODUCT OR (2) PRODUCT RELATED SERVICE OR SUPPORT, EVEN IF EXALT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSS OR DAMAGES AND WHETHER OR NOT SUCH LOSS OR DAMAGES ARE FORESEEABLE.d. IN NO EVENT SHALL EXALT'S AND ITS SUPPLIERS'/LICENSORS' AGGREGATE LIABILITY EXCEED AN AMOUNT EQUAL TO THE PURCHASE PRICE PAID BY PURCHASER FOR THE PRODUCT OR SERVICE THAT IS THE SUBJECT OF A CLAIM.  ANY CLAIM ARISING OUT OF OR RELATING TO THIS AGREEMENT MUST BE BROUGHT WITHIN ONE (1) YEAR AFTER THE OCCURRENCE OF THE EVENT GIVING RISE TO SUCH CLAIM.  IN ADDITION, EXALT DISCLAIMS ALL LIABILITY OF ANY KIND OF EXALT'S SUPPLIERS/LICENSORS.6SOFTWARE LICENSEa. Subject to the terms and conditions of this Agreement, Exalt hereby grants You a non-exclusive, non-transferable, non-sublicensable license to use the Software that comes with the Product, if any is provided as part of the Product, only as part of the normal operation, use and maintenance of the Hardware Product for which the Software was provided.   You may make back-up copies of such Software.  You shall not otherwise copy, distribute or alter the Software. Furthermore, except to the extent allowed by applicable law if located in the European Union, and then only with prior written notice to Exalt, You shall not disassemble or reverse engineer the Software in whole or in part or authorize others to do so.  No rights to distribute or sublicense the Software are granted herein.b. There may be certain third party owned software provided along with, or incorporated within the Product ("Third Party Software"), and which Third Party Software has a separate license agreement and which is governed exclusively by such separate license agreement ("Third Party License") and not this Agreement.  Such Third Party Software and applicable Third Party Licenses are listed in the document "EXALT COMMUNICATIONS, INC. THIRD PARTY SOFTWARE AND THIRD PARTY LICENSES USED WITH CERTAIN EXALT
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios128 203591-0112013-02-22PRODUCTS" available through the Web user interface application provided with this product.  Except as Exalt may otherwise inform You in writing, the Third Party License gives You at least the license rights granted above in Section 6(a), and may provide additional license rights as to the Third Party Software, but only with respect to the particular Third Party Software to which the Third Party License applies.  SUCH THIRD PARTY SOFTWARE IS PROVIDED WITHOUT ANY WARRANTY FROM EXALT AND ITS LICENSORS, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT.c. Exalt and its licensors are the sole and exclusive owners of the Software, and all underlying intellectual property rights in the Software and Hardware Product. All rights not expressly granted to You relating to the Software are reserved by Exalt and its licensors.  You take unencumbered title to the Hardware Product, subject to Exalt's and its licensors' ownership in the underlying intellectual property, upon payment in full to Exalt or the Exalt reseller for the Product(s).d. All licenses to the Software hereunder shall terminate if You fail to comply with any of the provisions of this Agreement and do not remedy such breach within thirty (30) days after receiving written notice from Exalt.  You agree upon termination to immediately cease using the Software and to destroy all copies of the Software which may have been provided or created hereunder.7GOVERNMENT RESTRICTIONSa. You agree that you will not export or re-export the Products without Exalt's prior written consent, and then only in compliance with all requirements of applicable law, including but not limited to U.S. export control regulations.  You have the responsibility to obtain any required licenses to export, re-export or import the Products.  You shall defend, indemnify and hold Exalt and its suppliers/licensors harmless from any claims arising out of Your violation of any export control laws relating to any exporting of the Products.  By accepting this Agreement and receiving the Products, You confirm that You are not listed on any governmental export exclusion lists and will not export or re-export the Products to any country embargoed by the U.S.  Applicable export restrictions and exclusions are available at the official web site of the U.S. Department of Commerce Bureau of Industry and Security (www.bis.doc.gov). b. For purchase by or on behalf of governmental entities (including federal, state or provincial, and local), the governmental entity's rights in any technical data and software in the Products include only those rights customarily provided to the public as defined in Exalt's standard Agreement.  In connection with any purchase by or on behalf of a U.S. governmental entity, Exalt's customary commercial license in technical data and software is provided in accordance with FAR 12.211 (Technical Data) and FAR 12.212 (Software) and, for Department of Defense transactions, DFAR 252.227-7015 (Technical Data - Commercial Items) and DFAR 227.7202-3 (Rights in Commercial Computer Software or Computer Software Documentation).  If a governmental entity has a need for rights not conveyed under these terms, it must negotiate a mutually acceptable written agreement with Exalt specifying and specifically conveying such rights.  Any use, modification, reproduction, release, performing, displaying or disclosing of the Exalt Software by a governmental entity shall be governed solely by the terms of this Agreement.8CONFIDENTIALITYPurchaser acknowledges and agrees that information supplied by Exalt in connection with the Product or this Agreement and designated by Exalt as confidential is the confidential information
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1292013-02-22of Exalt, which confidential information includes the Software.  Purchaser agrees: (i) to hold the confidential information in confidence using the same degree of care that it uses to protect its own confidential information of similar importance, but not less than a reasonable degree of care, (ii) not to make use of confidential information other than as contemplated by this Agreement, and (iii) not to reproduce confidential information except as expressly authorized by this Agreement.  Purchaser's obligations with respect to confidentiality do not apply to information which: (i) becomes generally available to the public other than as a result of unauthorized disclosure by Purchaser, or (ii) was in Purchaser's possession prior to disclosure by Exalt.9MISCELLANEOUSYou shall not sell, transfer or assign this Agreement without the prior written consent of Exalt.  Any act in derogation of the foregoing shall be null and void, and You will remain obligated under this Agreement.  This Agreement shall benefit and be binding upon the parties to this Agreement and their respective permitted successors and assigns.  The waiver or failure of either party to exercise in any respect any right provided for in this Agreement shall not be deemed a waiver of any further right under this Agreement.  If any provision of this Agreement is held by a court of competent jurisdiction to be contrary to law, the remaining provisions of this Agreement will remain in full force and effect.  This Agreement and any disputes arising out of, or related to, this Agreement, its termination or the relationship of the parties will be governed by and construed in accordance with the laws of the State of California, excluding its conflict of laws principles and excluding the United Nations Convention on Contracts for the International Sale of Goods.  All disputes arising in connection with this Agreement, the Products or Services shall be administered by the American Arbitration Association under its commercial arbitration rules by a single arbitrator appointed in accordance with the rules. Both parties consent that the arbitration shall take place in Santa Clara County, California. The award rendered by the arbitrator shall be final and binding on the parties and judgment on the award may be entered in any court having jurisdiction thereof.  Any litigation relating to this Agreement or the arbitration shall take place in the state courts of Santa Clara County or in the federal courts of the Northern District of California. The foregoing notwithstanding, Exalt may obtain preliminary and/or permanent injunctive relief in any court of competent jurisdiction worldwide to enforce the terms of Sections 6, 7 and 8.  Purchaser hereby consents and submits to the jurisdiction and venue of these courts and agrees that process may be served in the manner provided or allowed by California or federal law. In any action or proceeding to enforce rights under this Agreement, the prevailing party shall be entitled to recover costs and attorneys' fees. This Agreement represents the complete agreement and understanding of the parties with respect to the subject matter herein.  This Agreement may be modified only through a written instrument signed or otherwise agreed to by both parties. Rev 4-6-2012PT
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios130 203591-0112013-02-22Copyright NoticesThis section presents copyright notices for third-party software licensed to Exalt Communications, Inc.Net-SNMPThe following copyright notice applies to the open-source licensing agreement for Net-SNMP.Copyright 1989, 1991, 1992 by Carnegie Mellon UniversityDerivative Work - 1996, 1998-2000Copyright 1996, 1998-2000 The Regents of the University of CaliforniaAll Rights ReservedPermission to use, copy, modify and distribute this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notice appears in all copies and that both that copyright notice and this permission notice appear in supporting documentation, and that the name of CMU and The Regents of the University of California not be used in advertising or publicity pertaining to distribution of the software without specific written permission.CMU AND THE REGENTS OF THE UNIVERSITY OF CALIFORNIA DISCLAIM ALL WARRANTIES WITH REGARD TO THIS SOFTWARE, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS.  IN NO EVENT SHALL CMU OR THE REGENTS OF THE UNIVERSITY OF CALIFORNIA BE LIABLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM THE LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.Network Associates Technology, Inc.Copyright (c) 2001-2003, Networks Associates Technology, IncAll rights reserved.Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:*  Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.*  Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.*  Neither the name of the Networks Associates Technology, Inc nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ''AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1312013-02-22NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.Cambridge Broadband, Ltd.Portions of this code are copyright (c) 2001-2003, Cambridge Broadband Ltd.All rights reserved.Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:*  Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.*  Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.*  The name of Cambridge Broadband Ltd. may not be used to endorse or promote products derived from this software without specific prior written permission.THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL THE COPYRIGHT HOLDER BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.Sun Microsystems, Inc.Copyright © 2003 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara,California 95054, U.S.A. All rights reserved.Use is subject to license terms below.This distribution may include materials developed by third parties.Sun, Sun Microsystems, the Sun logo and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries.Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:*  Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.*  Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.*  Neither the name of the Sun Microsystems, Inc. nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ''AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios132 203591-0112013-02-22PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.Sparta, Inc.Copyright (c) 2003-2005, Sparta, IncAll rights reserved.Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:*  Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.*  Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.*  Neither the name of Sparta, Inc nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ''AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.Cisco, Inc.Copyright (c) 2004, Cisco, Inc and Information NetworkCenter of Beijing University of Posts and Telecommunications.All rights reserved.Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:*  Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.*  Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.*  Neither the name of Cisco, Inc, Beijing University of Posts and Telecommunications, nor the names of their contributors may be used to endorse or promote products derived from this software without specific prior written permission.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1332013-02-22THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ''AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.Fabasoft R&D Software GmbH & Co.Copyright (c) Fabasoft R&D Software GmbH & Co KG, 2003oss@fabasoft.comAuthor: Bernhard PenzRedistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:*  Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.*  Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios134 203591-0112013-02-22IndexAAC adapter 24Administration Settings page 40administrator privileges 34Advance Encryption Standard 41AES 41AIS enabling//disabling 57alarm conditions 37alarms 55, 72clearing 76Alarms page 72AMI 57antennasalignment 30, 105Canada 114mounting 27indoor 30mounting height 6site preparation considerations 6transmission line 28troubleshooting 105BB8ZS 57back-to-back bench test 8, 107back-to-back bench test configuration 107Bandwidth parameter 51battery source 24BER 79browsers 33buzzer timeout selection parameter 54CcablesEthernet (CAT5e) 8RF 6T1/E1 8troubleshootingimproper RF cable termination 104CLI 32main menu 32configuration file 46connectionsRSL Sync 95sync distribution accessory 96TDM 95Two-radio pin Internal Sync Out/In 96connectors 22GPS/RSL 22Power/Ethernet 22, 96T1/E1 1&3 22T1/E1 2&4 22TDM 95Current BER field 74Current RSL field 74Ddate and time 40DC power source 24Diagnostic Charts page 79dimensions 87duplex settings 55Dynamic Frequency Selection (DFS) 52, 110EE1 channels 58E1 Interface Configuration page 58effective isotropic radiated power (EIRP) 9Endpoint Identifier 35, 50Errored Seconds (ES) field 75Ethernet configuration parameters 58Ethernet connectors 96Ethernet interface 94throughput settings 57Ethernet Interface Configuration page 55Event Log page 76ExaltCalc tool 9, 103external loopback modes 59Ffactory default settings 27, 47fade margin 6, 106File Activation page 46, 49File Transfer page 46file transfers 46filesactivating stored 49default configuration file 47flywheeling 16frame length See TDD framefrequencycenter 6Ggateway (default) 47GPS Information page 71GPS synchronization 53, 71GPS/RSL connector 22
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1352013-02-22GPS/RSL LED 23grounding 105GUIACS (Automatic Channel Selection)page 68Administration Settings page 40Alarms page 72browsers supported 33description 33Diagnostic Charts page 79E1 Interface Configuration page 58Ethernet Interface Configuration page 55Event Log page 76File Activation page 46, 49File Transfer page 46GPS Information page 71IP address (default) 33log in 34login privileges 34navigation panel 37NTP and Time Zones Configurations 42Performance page 74QoS configuration 63Radio A configuration 33Radio Information page 39Reboot page 85Spectrum Analyzer page 81summary status information 36Syslog configuration 70System Configuration page 50T1 Interface Configuration page 57T1/E1 Configuration page 57VLAN page 60Hhop 7hub 13IinterfacesEthernet 94power 94RF 94T1/E1 94interference 75interference profile 6Internal Sync Out/In (two-radio pin connec-tion) 96IP address conflicts 33IP address subnet 33IP settings 8LLEDsDATA + POWER 23ETH2 or ETH3 23GPS/RSL 23Power/ETH1 23T1/E1 1&3 23License Key 41lightning arrestor 6lightning arrestors 30Line Build Out (LBO) 57Line Code 57link 6orientation 10RF link testing 8synchronization 10Link Distance parameter 52link margin 106link parameters 36Link Security Key 40Link Security Key parameter 48login names 34login privileges 34loopback 57, 58, 59external (local) 59external (remote) 59internal 59MMaximum RSL field 75MIB files 46Minimum RSL field 75Minimum RSL Timestamp field 75Mode parameter 51mountinghardware 21multi-link network 13multipath 103multipath propagation 104muting 55Nnoise profile 6Ooffset timing 15Pparameters
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios136 203591-0112013-02-22buzzer timeout selection 54passwords 8, 34path obstruction 105performance degradation 103Performance page 74powersystem LEDs 25Power connector 96power interface 94Power/Ethernet connector 22QQoS configuration802.1p based 65IPv4/IPv6 based 66MAC DA based 63MAC SA based 64VLAN ID based 64Rradiodefault settings 11grounding 105initiation tasks 19installation tasks 19maximum transmit power setting 51mounting 6, 21rebooting 76, 85Radio A 11Radio A configuration 7radio configuration 7radio firmware files 46Radio Information page 39Radio Transmit Power parameter 50Reboot page 85receiver threshold 6record keeping 20Regulatory Domain Database (RDD) 46regulatory requirementsEIRP 118USA 113repeater 13RESET button 23RF connector termination 24RF Frequency parameter 51RF interface 94RF interference 104RF lightning arrestor 30RF output power 9RSL 9current RSL readings 74diagnostics 79Maximum RSL field 75Minimum RSL Timestamp field 75monitor for performance 103RSL Sync 95RSL voltage 31Ssafety 109Set to E1 button 57Set to T1 button 57shipping box contents 7site preparation 6SNMP 17, 43SNMP Traps 44specifications 87Spectrum Analyzer page 81Swap button 46, 49sync distribution accessory 96sync source 16synchronization 12System Configuration page 50system latency 6system parametersdefault settings 27system performance 74system reboot 76system settingsCurrent BER field 74Errored Seconds (ES) field 75grounding 105Maximum RSL 75Minimum RSL field 75Time Since Reset field 75Unavailable Seconds field 75system specifications 88TT1 Interface Configuration page 57T1/E1 1&3 connector 22T1/E1 2&4 connector 22T1/E1 2&4 LED 23T1/E1 circuits 57T1/E1 Configuration page 57T1/E1 interfaces 94T1/E1 loopback 59TDD factors 9
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1372013-02-22TDD frame length 6TDD Frame Size parameter 52TDM circuits 51TDM connections 95TDM connectors 95Telnet menu 32Telnet session 32temperature 79testing 107back-to-back bench 8threshold 108threshold testing 108time division duplex (TDD) SeeTDD frameTime Since Reset 75timing, offset 15transmission linecoaxial 28transmitteroutput power 8traps 44troubleshooting 79, 102UUnavailable Seconds (UAS) 75unfaded error-free performance 8Update button 40user privileges 34VVLAN 16tagging 16VLAN page 60voltage test 31VSWR 104
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios138 203591-0112013-02-22
Exalt Installation and Management GuideExtendAir (TDD) Series Digital Microwave Radios203591-011 1392013-02-22
203591-0112013-02-22

Navigation menu