Essity Hygiene and Health 682930 Level Sensor for Tork EasyCube communicates via 2.4 GHz radio with the Tork EasyCube Gateway. User Manual 0025194

Essity Hygiene and Health AB Level Sensor for Tork EasyCube communicates via 2.4 GHz radio with the Tork EasyCube Gateway. 0025194

User Manual

Tork EasyCubeTM
User Manual
www.torkglobal.com
1 Introduction - Tork EasyCubeTM
Tork EasyCube™ is an Internet of Things (IoT) solution for data driven
cleaning management. Tork dispensers and bins are equipped with
sensors that communicate their status to a cloud based system.
Also, the system includes visitor registration units that count people
passing into a washroom area or a cubicle. Combining these
information sources gives many opportunities to improve both
The information is automatically transferred via the web application
to a facility manager or a building service team to stay in control and
take actions. The web application includes digital cleaning rounds
and follow-up, tailored to managers and their teams - empowering
users to work smarter.
Original instruction.
1
Figure 1. Each dispenser is wirelessly connected to an information system that
can be utilized by both a Facility Manager as well as cleaning staff, in order to
2
2 Get an instant overview
At any point in time the system will provide a quick overview of the
status of the installed dispensers through a web based dashboard.
Instantly the user of the web application, for example a facility man-
ager, will be able to spot if dispensers are about to become empty.
2.1 Before you get started
To be able to get started with Tork EasyCube there are some
activities that need to be performed.
Initially the customer together with Essity will determine which
rooms will be included and the required number of gateways (see
chapter 3.6 for further explanation) to support these locations.
The number of gateways required for a location depends upon the
distribution of the connected rooms within the building and also the
construction material of the building walls.
The installation is done by professional installers.
The installation instruction is available in the Tork EasyCube Install tool.
Figure 2. Status Red indicates
very soon out-of-paper and Yellow
Green needs no attention. Add a
dashboard measurement of a critical
location to track its usage.
3
Figure 3. The different components for Tork EasyCube
3 Technical components and Wireless Communication
for Tork EasyCube
Gateway
Cloud
2.4GHz Radio
3G
User InterfaceSensors
Internet
Connection
in status occurs, the gateway forwards the information to the Tork
EasyCube. It is in the application server in the cloud where all data
is processed and aggregated to useful information. The customer
is provided access to the Tork EasyCube web application for
management and analysis of collected information.
installation. 4
3.1 Sensors
There are a couple of different sensors that generates data points
for Tork EasyCube. The data from sensors are interpreted into
useful and actionable insights for users.
in Tork dispensers
• Bin sensors measure the level of waste in Tork bins
• Dispensers with embedded sensors measures foam soap level
All sensors communicate with the Gateway via radio on the 2.4GHz
frequency band. The sensors are capable of two directional com-
munications. Each unit transmits usage data as well as operational
conditions (such as battery level). It can also be instructed to fall
asleep in situations when equipment is in transit or not used for a
longer period.
Note that installed Sensor Communication Units for the full dis-
penser assortment continue to be available for existing customer
installations. For new installations the Level Sensor and the Sensor
Communication Unit are provided for the dispenser systems ac-
cording to the list in this user manual.
5
3.1.1 Level Sensor
The Level Sensor is added to a special slot in the dispenser. The
by colors.
Green: indicates that the dispenser still has enough
paper remaining.
Red: indicates that the dispenser is almost empty.
Wipe off with a dry cloth each 6 month or when needed
to remove dust.
Article number: 682930
The Level Sensor is used for the following dispensers Article number
Tork Elevation Xpress Hand Towel Dispenser 552020
552028
Tork Image Design Xpress Hand Towel Dispenser 463002
Tork Xpress Medium/Large Recessed Cabinet Towel Adapter 309695
309696
Tork Image Design Mini Jumbo Bath Tissue Roll Dispenser 465500
Tork Elevation Matic Hand Towel Roll Dispenser 5510282
5510202
Tork Elevation Matic Hand Towel Roll Dispenser –
with Intuition Sensor 5511202
5511282
Figure 4.
Level Sensor
6
3.1.1.1 Battery information for the Level Sensor
Each Level Sensor is operated by an Essity approved battery,
CR2450. The bracket where the sensor is placed looks different
for different dispensers, the illustration shows one example. The
battery change procedure is the same for all the dispensers.
To change battery:
1
2 3
Take out the level sensor from the bracket
in the dispenser Open the cover
Caution: Risk of explosion if the
battery is replaced by an incorrect
type.
4
6 7
5
Remove the battery Replace with a new Essity approved battery
Put the sensor into the bracket in the
dispenser again.
Recycle used batteries according to
regulations.
Close the cover again
8
3.1.2 Tork EasyCube Sensor Communication Unit
The sensor communication unit is added to a special slot in the
the Tork EasyCube by colors.
Each sensor is operated by an embedded battery.
Wipe off with a dry cloth each 6 months or when
needed to remove dust. Article number: 682870
Figure 5. Sensor
• Green: indicates that the dispenser still have
enough paper remaining.
the dispenser.
Red: indicates that the dispenser is almost
empty.
9
Works for Article number
Tork Image Design Matic Hand Towel Roll Dispenser
Tork Image Design Matic Hand Towel Roll Dispenser, Recessed
Tork Image Design Matic Hand Towel Roll Dispenser, in-Wall Recessed
461002
461022
461023
Tork Elevation PeakServe Hand Towel Dispenser 552520
552528
Tork Elevation Twin Mini Jumbo Bath Tissue Dispenser 5555200
5555290
Tork Coreless Elevation High Capacity Bath Tissue Dispenser 473200
473208
10
3.1.3 Dispensers with embedded sensors
Tork dispensers such as Tork Foam Soap
Dispenser with Intuition sensor™ do not
need an additional sensor. Instead, there is
an additional radio component in the cassette
which forwards information to the gateway via
2.4 GHz radio.
The system runs on the same battery as the
dispenser, no additional battery is needed.
Article numbers: 682830, 682840, 466200
Figure 6. The battery
operated, touch free Tork
Foam Soap Dispensers
11
3.1.4 Tork EasyCube Visitor Registration Unit
The Visitor Registration Unit counts the number of people going in
and out of a room. The number of visitors can be used as a guideline
for when washrooms need to be cleaned.
end pieces and rotate the center unit 90° to change direction. Place
one sender and one receiver at the door frame to the entry of the
room. The sensor has a range of up to 1.7 meters / 5.5 feet. A con-
environments and applications.
Each sensor is operated by an embedded battery.
Article number: 682850
Figure 7. Visitor
registration unit
12
3.2 Tork EasyCube Gateway
The Gateway collects the data from the sensors
and sends information to the Tork EasyCube
system. The gateway acts as a communication
hub for all the sensors that have been paired
with it. The unit collects and processes incoming
sensor data.
The gateway needs to be connected to a power
outlet all the time.
The gateway is installed away from water and as
high up as possible for best performance.
Figure 8. Gateway
The gateway has a built-in 2G/3G modem used to connect to Internet.
No access to local physical networks is needed. Communication
between sensors and the gateway is based on Essity proprietary
protocol. Article number: 682920
In order to cover larger areas, several gateways may be needed. As
each gateway has communication capabilities with the server, they
can be installed over a large area with no requirements of in-between
communication.
13
14
Radio Frequency 2.405 GHz
Radio Standard IEEE 802.15.4
Gateway
Power adapter Input: 100-240V AC, Output: 5V DC, 1.2A
Internet connection 2G / 3G
Dimensions
188 x 188 x 33mm / 7.4 x 7.4 x 1.3 inches
Level Sensor
Sensors Range measurement
Battery 3V, 610mAh, CR2450
Dimensions
42 x 40 x 12mm / 1.6 x 1.6 x 0.5 inches
Sensor
Communication Unit
Sensors Light
Battery 3V, 500mAh, CR3032
Dimensions 62 x 50 x 6mm / 2.4 x 2.0 x 0.2 inches
Visitor
Registration Unit
Sensors Infrared (IR)
Battery 3.6V, 2.1Ah, 2/3A
Dimensions 158 x 23 x 23mm / 6.2 x 0.9 x 0.9 inches
Tork Foam Soap
Dispenser with
Intuition sensorTM, S4
Sensors Infrared (IR)
Battery 4pcs of R14
Dimensions 278 x 113 x 130mm/10.9 x 4.5 x 5.12 inches
Tork Bin, B1
Sensors Infrared (IR)
Battery 3.6V, 1.1Ah, 1/2AA
Dimensions 40 x 100 x 55mm/ 1.6 x 4.0 x 2,1 inches
Lithium metal content <1g
Warnings
Only use the power supply provided with Tork
EasyCubeTM.
Do not expose the battery for high temperatures,
disassemble it, damage it mechanically or put the
Only use the SIM card provided by Essity.
If any of the contents of the Tork EasyCubeTM appear
to be damaged or broken, contact Essity Customer
Service at 1 866 722 8675, for North America. For
Europe please contact your Essity representative.
16
Computer, server device or smartphone etc are not included.
The Tork EasyCube web application can be accessed from
modern web browsers.
Devices shown are not actual size.
Important:
Save this user manual for future reference.
If any changes to the installation are necessary, please contact
allowed. Tork EasyCubeTM must be returned to Essity after the end
of its service life.
17
FCC:
by the party responsible for compliance could void the user’s
authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this de-
vice must accept any interference received, including interference
that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable pro-
tection against armful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to ra-
dio or television reception, the user is encouraged to contact SCA
for support.
FCC ID: 2ABK3-682870 (article number 682870)
FCC ID: 2ABK3-682850 (article number 682850)
FCC ID:
2ABK3-682920 (article number 682920), contains FCC ID: QIPEHS6
FCC ID: 2ABK3-682830 (article numbers 682830, 682840)
FCC ID: 2ABK3-466200 (article number 466200)
FCC ID: 2ABK3-682930 (article number 682930) 18
IC:
This device complies with Industry Canada’s licence-exempt RSSs.
Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Industry Canada ICES-003 Compliance Label:
CAN ICES-3 (A)/NMB-3(A)
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage;
(2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Industrie Canada ICES-003 Étiquette de conformité:
CAN ICES-3 (A) / NMB-3 (A).
IC: 10866A-682870 (article number 682870)
IC: 10866A-682850 (article number 682850)
IC: 10866A-682920 (article number 682920), contains IC:
7830A-EHS6
IC: 10866A-682830 (article numbers 682830, 682840)
IC: 10866A-466200 (article number 466200)
IC: 10866A-682930 (article number 682930)
The WEEE Directive set collection, recycling
and recovery targets for all types of electrical
goods. The RoHS Directive set restrictions upon
European manufacturers as to the material
content of new electronic equipment placed on
the market.
The Battery directive regulates the manufacture
and disposal of batteries in the European Union
with the aim of improving the environmental
performance of batteries and accumulators.
CE marking is a mandatory conformity marking
for certain products sold within the European
Economic Area (EEA). The CE marking is also
found on products sold outside the EEA that
are manufactured in, or designed to be sold in,
the EEA. The CE marking is the manufacturer’s
declaration that the product meets the
requirements of the applicable EC directives.
The ETL Listed Mark is proof that the product
has been independently tested and meets the
applicable published standard.
5007054
20
21
22
Manufactured by Essity Hygiene and Health AB
SE-405 03 Göteborg, Sweden
Visiting address: Mölndals Bro 2, lndal
www.essity.com, www.torkglobal.com
Distributed by
Essity Professional Hygiene North America LLC
2929 Arch Street, Suite 2600
Philadelphia, Pennsylvania 19104
www.torkusa.com
Sensors, Gateway and Visitor Registration unit are
made in Sweden
Foam soap dispenser (stainless) is made in Poland
Foam soap dispenser (plastic) is made in China
Version G

Navigation menu