Elexa Consumer GBR1 Bridge User Manual

Elexa Consumer Products Inc. Bridge

User Manual

BRIDGE User ManualModel Name: BridgeModel#: GBR1Elexa Consumer Products2275 Half Day Road, Ste#160Bannockburn, IL 60015USA
Contents1 Overview 31.1 KeyFeatures ............................................. 31.2 Communication............................................ 31.2.1 GuardianRF ......................................... 31.2.2 RelayLinkTM ......................................... 31.2.3 Z-Wave ............................................ 32 Specifications 42.1 Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42.2 PerformanceSpecifications...................................... 42.3 HardwareSpecifications ....................................... 42.3.1 BridgeSpecifications..................................... 42.4 MechanicalSpecifications ...................................... 42.4.1 Tooling ............................................ 52.4.2 FitandFinish ........................................ 53 Functional Requirements 53.1 LEDs ................................................. 53.1.1 LEDBehavior ........................................ 53.2 Button................................................. 63.3 Power ................................................. 63.4 Guardian App and Device Pairing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63.4.1 GuardianApp ........................................ 63.5 FirmwareUpgrades.......................................... 63.6 GuardianRF.............................................. 63.7 RelayLinkTM ............................................. 64 Z-Wave 64.1 Z-WaveInclusion........................................... 74.2 Z-WaveExclusion........................................... 74.3 NWI.................................................. 74.4 Z-WaveSpecifications ........................................ 74.4.1 AssociationGroups(AGs).................................. 74.4.2 Compatible Command Classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 RelayLinkTM 95.1 Pinout................................................. 95.1.1 PowerGroup ......................................... 95.1.2 InputGroup ......................................... 95.1.3 OutputGroup ........................................ 96 Pad Printing 106.0.1 RequiredLogos/Labels ................................... 107 Packaging and Labels 108 Validation and Testing 109 Certifications 102
1 OverviewThe Guardian Bridge is a device that can communicate to a single valve controller over Guardian RF andto a security panel over wire, or a Z-Wave hub. This allows a security panel or Z-Wave hub to open/closethe valve controller and be alerted if a leak is detected.1.1 Key Features•GuardianRF, RelayLinkTM , Z-Wave•USB or 12V power1.2 Communication1.2.1 GuardianRFThe Guardian Bridge will be able to send the following commands to the valve controller:•Open the valve•Close the valveThe Guardian Bridge will receive the following events from the valve controller:•At least one sensor is wet•All sensors are dry•Valve opened•Valve Closed•Lowest temperature reported by any connected device1.2.2 RelayLinkTMThe Guardian Bridge will be able to send the following information over RelayLinkTM•At least one sensor is wet•All sensors are dryOR•Valve is open•Valve is closed1.2.3 Z-WaveThe Guardian Bridge will be able to send the following information over Z-Wave:•At least one sensor is wet•All sensors are dry•Valve is open•Valve is closed•Lowest Temperature reported by any connected device3
2 SpecificationsThis section describes the requirements and scope of the Guardian Bridge2.1 Environmental SpecificationsFeature DescriptionOperating Temperature Range 0°C to 70 °COperating Humidity Range 5% to 90% RH Non CondensingStorage Temperature Range -40°C to 75 °C - capable of opera-tion after a 20 minute transitionfrom storage to operating tem-peratureStorage Humidity Range 0% to 95% RH - capable of oper-ation after a 20 minute transitionfrom storage to operating humid-ityVibration All axes, amplitude: 2mm, fre-quency: 1Hz - 20,000HzMechanical Shock (Drop) 1m2.2 Performance SpecificationsFeature DescriptionRange 1000+ ft line of sight (Guardian RF)450+ ft line of sight (Z-Wave)Life Expectancy 10 yearsReliability 1st year 99%5 years 95%2.3 Hardware Specifications2.3.1 Bridge SpecificationsItem Description and SpecificationsLora RF module SX1276IMLTRT, IC RF TXRX 802.15.4 28VQFN  915Mhz Z-Wave  Module ; Range ZM5101 ; 908.4Mhz,and 916.0Mhz Input voltageGuardianRF Receive sensitivityZ-Wave Receive sensitivityGuardianRF TX powerOperation currentMaximum currentLEDs 3x White, same as valve controllerOTA Support remote FW upgrade (All MCUs)2.4 Mechanical SpecificationsThe 3D CAD shall be modeled on nominal dimensions and shall be the primary source of dimensionalinformation.4
Item Description and SpecificationsType PlasticResin Blue:3005U;Finish Same as valve controller2.4.1 ToolingTooling shall be good for over 300,000 injections.2.4.2 Fit and Finish•Flash allowance shall not to exceed 0.13 mm (0.005in). Flash applies to parting lines, ejector pins,ejector blades and ejection sleeves•Parting line mismatch shall not exceed 0.13 mm (0.005 in)•Gate & Ejector pin scar/vestige shall be sub-flush unless otherwise specified•Cosmetic surfaces shall be free of nicks, scratches, or tooling marks•The finish and color shall be similar to the Guardian valve controller. Non-visible surfaces may not betextured•Guardian logo, power, Z-Wave, and Guardian RF icons will be pad printed white3 Functional RequirementsThe Guardian Bridge translates communication from GuardianRF to either RelayLinkTM or Z-Wave.3.1 LEDsThe power and GuardianRF LEDs on the front of the Guardian Bridge will behave the same as the Guardian.The Z-Wave LED will be off when not paired to a Z-Wave hub, blinking (same pattern as WiFi light onvalve controller when hotspot is on) and on when paired to the hub.3.1.1 LED BehaviorLED Behavior Events1st LED (Power) LED is ON Bridge is powered onLED is OFF Bridge is powered off2nd LED (Z-Wave)LED is ON Bridge is included in a Z-WavenetworkLED is double-blinking Bridge is in inclusion/exclusionmodeLED is off Bridge is not included in a Z-Wave network3rd LED (GuardianRF) LED blinks Bridge has sent/received aGuardianRF transmission5
3.2 ButtonThe single button will on the back will be used to pair the Bridge with a valve controller or a Z-Wave hub.A single press will be used to pair the Bridge to a valve controller (like shaking the leak detector). A triplepress (3 presses in under 2 seconds) will put the bridge in Z-Wave inclusion mode if it has not been includedyet, or in exclusion mode if it is currently included. The button will also be used for factory reset. To factoryreset, the button will be held for 10 seconds.3.3 PowerThe Bridge will come with a plug-in 5V adapter with a micro-USB connector. The power supply will have anon-removable wire of 4-6 feet. It will be gray and include the matching Guardian velcro strap. If sourcinga gray power supply will cause delays or too much added expense, a black power supply can be used andthe Guardian velcro strap can be omitted.3.4 Guardian App and Device PairingThe Bridge can be connected to the Guardian App if the user has a valve controller. There can be only oneBridge connected to each valve controller.3.4.1 Guardian AppThe settings and information displayed to the user are TBD3.5 Firmware UpgradesThe Bridge will be capable of OTA firmware updates. The GuardianRF MCU will be updated overGuardianRF, the Z-Wave module will be updated over Z-Wave. In case an OTW firmware update is requiredduring development and testing the device will be designed in such a way that the firmware can be updatedwithout complete disassembly.3.6 GuardianRFWhen any leak sensor is triggered the valve controller will send a message over GuardianRF to the bridgethat one of the sensors is wet. Once all of the sensors are dry, the valve controller will send a message to thebridge that all sensors are dry When the Bridge receives a command to open or close the valve from Z-Waveor RelayLink™, an open or close command will be sent to the valve controller via GuardianRF.3.7 RelayLinkTMRelayLink™is an revolutionary, innovative new communication protocol developed by Elexa Consumer Prod-ucts to be faster and easier to use than current standards. Please see the RelayLink™Specification Documentfor more information4 Z-WaveWhen the Bridge receives a ‘leak detected’ message it will inform the Z-Wave hub if it is paired. It willalso inform the hub when an ‘all sensors dry’ message is received. The hub will also be able to send ‘openvalve’ and ‘close valve’ messages to the bridge to relay to the valve controller. When included in the Z-Wavenetwork, the Bridge will appear as two devices:•An On/Off Switch6
•A Leak Sensor•A temperature sensor (see §4.4.1)4.1 Z-Wave InclusionThe Bridge will enter inclusion mode when first powered on (if not already included in a Z-Wave network)and will stay in inclusion mode for 30 seconds. After 30 seconds, if the Bridge is not included, pressingthe button on the device 3 times in less than 2 seconds will put it back in inclusion mode for 30 seconds.When in inclusion mode, the Z-Wave LED will double blink. After successful inclusion the Z-Wave LED willremain solid.4.2 Z-Wave ExclusionIf the hub is in exclusion mode and the Bridge is included in the Z-Wave network, a triple press of the Bridgebutton will put the device in exclusion mode. Upon successful exclusion the Z-Wave LED will turn off.4.3 NWIThe Bridge will support NWI -Network Wide Inclusion4.4 Z-Wave Specifications4.4.1 Association Groups (AGs)Association Group Description01 LifelineThis AG sends Binary Report when valve is opened or closed,Supports Device Reset Locally. When any leak sensor is wet, thedevice will send a leak notification. When all sensors are dry, thedevice will send a ‘leak cleared’ notification.02 This AG is sent an Open/Close Basic Report03 Sensor Multilevel Report containing the temperature informationevery 60 minutes7
4.4.2 Compatible Command ClassesCommand Class NotesCOMMAND CLASS VERSION V2(86)Returned Value: 03 04 3D 01 01 01 00Z-Wave Library Type: 03 (Enhanced Slave)Protocol Version: 04 3DProtocol Sub-Version: 01 01Application Version: 01Application Sub-Version: 00COMMAND CLASS BASIC V1 (20) -COMMAND CLASS SWITCH BI-NARY V1 (25)Binary Switch commands will open/close the valve. Re-ports are used to communicate valve opening/closing ValveOpenFF Valve Closed: 00COMMAND CLASS SENSOR MUL-TILEVEL V11 (31)The Multilevel CC is used to communicate the temperaturerecorded by the Valve Controller in the Guardian system.This is only reported to association group 3.Returned Value: 01 XX XXSensor Type: 01 (Temperature)Precision/Scale/Size (Celsius): 01 (Precision = 000; Scale= 00; Size = 001)Precision/Scale/Size (Farenheit): 01 (Precision = 000;Scale = 00; Size = 001)Sensor Data: 00 FF (-125 125 in Degrees Fahrenheit orCelsius)COMMAND CLASS MULTI CHAN-NEL V4 (60)The Multi Channel Command Class is used to distinguishcommands to/from the Valve Controller endpoint (end-point 1) and the Leak Detector endpoint (endpoint 2).COMMAND CLASS MULTI CHAN-NEL V4 (60)The Multi Channel Command Class is used to distinguishcommands to/from the Valve Controller endpoint (end-point 1) and the Leak Detector endpoint (endpoint 2).COMMAND CLASS ASSOCIATIONV2 (85)Group 1 Group 1 is the “Lifeline” group, which can holdfive devices.COMMAND CLASS ASSOCIATIONGRP INFO V3 (59)-COMMAND CLASS MANUFAC-TURER SPECIFIC V2 (72)Returned Value: 02 1F 01 02 03 04Manufacturer ID: 02 1FProduct Type: 01 02Product ID: 03 04COMMAND CLASS DEVICE RESETLOCALLY V1 (5A)-COMMAND CLASS POWERLEVELV1 (73)-COMMAND CLASS SUPERVISIONV1 (6C)-COMMAND CLASS FIRMWARE UP-DATE MD V4 (7A)-COMMAND CLASS CONFIGURA-TION V1 (70)See Configuration Command Class Parameters8
COMMAND CLASS NOTIFICATIONV8 (71)The Guardian Bridge sends a notification report to associ-ation group 1 when any Leak Detector in the system sensesmoisture.Returned Value: 00 00 00 FF 05 XX 00 00V1 Alarm Type 00 (Unsupported)V1 Alarm Level 00 (Unsupported)Notification Status: FF (Unsolicited Reporting is Enabled)Notification Type: 05 (Water Alarm)Leak Detected Event: 02 (Water Leak Detected, UnknownLocation)Leak Removed Event: 00 (Event Inactive)Sequence/Reserved/Event Parameters: Length 00Notification Event Parameters: 00 (No Event Parameters)COMMAND CLASS ZWAVE PLUSINFO V2 (5E)Returned Value: 01 05 00 15 00 15 00Z-Wave Plus Version: 01Role Type: 05Node Type: 00Installer Icon Type: 15 00User Icon Type: 15 005 RelayLinkTMRelayLinkTM provides power and two way communication between an ancient security panel and theGuardian Bridge, one bit at a time.5.1 PinoutGroup Power Input OutputPin Number 1 2 3 4 5 6 7Label +12V GND IN GND NO COM NC5.1.1 Power GroupPins 1 and 2 are used to supply power from a 12V security panel.5.1.2 Input GroupPins 3 and 4 are a configurable input. With the Guardian App the Bridge can be set to send an open orclose command to the valve controller. Details are TBD5.1.3 Output GroupPins 5, 6, and 7 are the outputs. The Guardian App can be used to configure the output to be indicate:•Valve open•Valve closedOR•At least one leak sensor is wet•All sensors are dry9
6 Pad PrintingPad printing will be done in white, black, or gray (TBD).6.0.1 Required Logos/LabelsThe following must be printed on the Bridge:•Guardian logo on top•Power symbol on 1st LED•Z-Wave symbol on 2nd LED•GuardianRF symbol on 3rd LED•RelayLinkTM pin numbers7 Packaging and Labels8 Validation and Testing9 Certifications10STATEMENT OF WARRANTY : 1 Year Limited WarrantyElexa Consumer Products will not honor the warranty if the product is purchased through an unauthorized seller.Elexa Consumer Products, Inc. (”ECP”) warrants to the original retail purchaser (”Purchaser”) that the Bridge  (the “Product”) will be free of defects in materials or workmanship under use for one (1) year from the date of purchase (the “Warranty period”).For the Purchaser only, if the Product fails to perform as specified during the Warranty Period due to defective parts or faulty workmanship, ECP will repair or replace the defective or damaged parts of the Product. Normal wear and tear is not covered nor is abnormal use, misuse, mishandling, faulty installation, improper shipping, damage caused by disasters such as fire, flood or earthquake, neglect, accident or tampering. This warranty covers only normal use in the United States or Canada.To obtain warranty service during the Warranty Period, call Guardian Customer Service (1-855-249-1754) or email: support@getguardian.com for instructions on sending damaged parts and documentation for a Return Merchandise Authorization (RMA). Products returned to ECP for repair or replacement without authorization will be returned at the sender’s expense. All warranty claims must be accompanied by a legible copy of the original receipt showing date and details of purchase. ECP will repair or replace defective parts and return them at ECP’s cost by a shipping method selected by ECP.When contacting ECP  to obtain an RMA, Purchaser may request expedited return shipping at Purchaser’s expense.THIS WARRANTY IS NOT TRANSFERABLE, AND, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IS IN LIEU OF ALL OTHER WARRANTIES, REPRESENTATIONS AND CONDITIONS, EXPRESSED OR IMPLIED, STATUTORY OR OTHERWISE, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. NO OTHER PERSON OR REPRESENTATIVE IS AUTHORIZED TO MAKE ANY OTHER WARRANTY ON BEHALF OF ECP OR ASSUME FOR ECP ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT. IN NO EVENT WILL ECP BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, INCLUDING DAMAGES DUE TO ECP’S NEGLIGENCE.THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE AND COUNTRY TO COUNTRY.
Bridge FCC and IC Statement   Bridge is used to connect Guardian Valve Controller to Z-wave network. Bridge is also used to control Valve Controller open/close. The Guardian RF(915Mhz) is used for the communication between Bridge and Valve Controller.   The Z-wave (908.40Mhz and 916Mhz) is used for the communication between Bridge and other Z-wave Devices. These 2 frequency are switched automatically.   Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna.   -- Increase the separation between the equipment and receiver.    -- Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.   -- Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:(1) This device may not cause interference; and(2) This device must accept any interference, including interference that may cause undesired operation of the device.

Navigation menu