Ecolink Intelligent Technology WST610 Wireless Sensor User Manual firefighter manual p1

Ecolink Intelligent Technology, Inc. Wireless Sensor firefighter manual p1

Manual

WST-610 Flood and Freeze Sensor patent pending Installation Manual & Users Guide  SPECIFICATIONS Frequency: 433 MHz  Operating Temperature: 32°-120°F (0°-49°C) Battery: One 3Vdc lithium CR2450 (620mAH)  Operating Humidity: 5-95% RH non condensing Battery life: up to 10 years  Compatible with Honeywell and 2GIG  Detection of standing Water within 1 second    Supervisory signal interval: 64 min(approx.)   Across Gold probes  Maximum current draw:  23mA during transmission Detect Freeze at 5C restores at 7C  Water resistant to XXX  OPERATION The WST-610 sensor is designed to detect water across the  gold probes and will alert immediately when present. The Freeze sensor will trigger when temperature is below 5C and will send a restoral at 7C.   ENROLLING  To enroll the sensor, set your panel into sensor learn mode.  Refer to your specific alarm panel instruction manual for  details on these menus.  On the WST-610, locate the vertical line on the side of the sensor. This indicates the location of the internal reed switch. To learn in the flood sensor, initiate a transmission by tapping the included magnet to this spot. Repeat as needed by the control panel. The flood sensor will enroll as Loop 1. To learn in the freeze sensor, initiate a transmission by holding the magnet to the reed for at least 2 seconds. The freeze sensors will enroll as Loop 2. You can also trigger the unit by placing a wet finger across the gold probes for a few seconds. Since the flood/freeze are two sensors in one, you will need to enroll them as TWO separate sensors if you desire to use them both.  **CURRENT SAMPLES DO NOT SUPPORT 2 SECOND FREEZE ENROLLMENT, MUST BE ENROLLED BY MANUALLY ENTERING THE SERIAL NUMBER ****   PLACEMENT   Place the flood detector anywhere that you wish to detect a flood or freezing temperature.  Under a sink,       in or near a hot water heater, a basement or behind a washing machine.  If you would like to make sure the flood     does not move from its intended location you can use the provided sensor cover and mount it to the wall or floor       Water Height Adjustment The Firefighter comes with 2 sets of rubber feet that can be used to adjust the height of the probes to either 3/16th in or 3/8th in. Place the rubber feet in the position shown below if you wish to raise the detection level of water         Testing the unit By using the magnet you can send a Flood OR Freeze transmission. Place the magnet on the line on top of the case and remove it within 1 second, this will send a Flood transmission (Loop1), if you hold the magnet for 2 seconds, it will send a Freeze transmission (Loop2). Placing wet fingers on any two probes will also trigger a flood Draft Picture Placement of rubber feet DRAFT MANUAL- NOT for PRODUCTION
transmission.      REPLACING THE BATTERY When the battery is low a signal will be sent to the control panel. To replace the battery: 1. Carefully remove the white rubber feet on the bottom of the flood detector. 2. Remove the 3 screws and open the case. Replace battery with a Panasonic CR2450 Lithium Battery 3. Replace the screws and rubber feet                                                                                                                                                                                                                       FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate  radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio  communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful  interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to  correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment to an outlet on a different circuit from the receiver • Consult the dealer or an experienced radio/TV contractor for help.  WARNING: Changes or modifications not expressly approved by Encore Controls could void the user’s authority to operate the equipment.  This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.  C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de la dispositif.   FCC ID: XQC-WST610  IC:9863B-WST610  WARRANTY Ecolink  warrants that for a period of 2 years from the date of purchase that this product is free from defects in material and workmanship. This warranty does not apply to damage  caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications. If there is a defect in materials and workmanship under normal use within the warranty period Ecolink  shall, at its option, repair or replace the defective equipment upon  return of the equipment to the original point of purchase. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Ecolink   neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to  change this warranty, nor to assume for it any other warranty or liability concerning this product. The maximum liability for Ecolink   under all circumstances for any warranty issue shall be  limited to a replacement of the defective product. It is recommended that the customer check their equipment on a regular basis for proper operation.  THE LIABILITY OF ECOLINK ,  OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM DETECTOR OR UNDER THE TERMS OF THIS LIMITED  WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF A SMOKE ALARM DETECTOR AND, IN NO CASE, SHALL ENCORE CONTROLS ,  OR ANY OF ITS PARENT OR SUBSIDIARY  CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSSES OR DAMAGES RESULTING FROM THE FAILURE OF THE SMOKE ALARM DETECTOR OR FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS  OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE COMPANY’S NEGLIGENCE OR FAULT.  The WST-601 detector does not detect the presence of smoke, heat, or fire directly. It relies solely on the presence of an audio alarm signal generated by an existing smoke or fire detector in proximity to the WST-601 detector to make such a determination. The WST-601 detector must be used with smoke detectors certified according to UL Standards, and in strict accordance with the installation and operation instructions provided with such detectors. It is the owner’s responsibility to ensure that smoke or fire detectors used in conjunction with the WST-601 detector are maintained and tested on a regular basis in accordance with the manufacturer’s instructions. Ecolink  expressly disclaims any responsibility for the failure of the WST-601 detector to detect the presence of smoke or fire due to the failure of any smoke or fire detector used in conjunction with the WST-601 detector to operate properly due to any condition, including improper installation, operation,  maintenance or testing of such smoke or fire detector.                Ecolink Intelligent technology Inc. 2055 Corte Del Nogal Carlsbad CA 92011 855-632-6546
PN WST-610  R0.01 REV DATE:  patent pending

Navigation menu