Datalogic 0008 Hand Held Bluetooth Barcode Scanner User Manual 0 GryphonBT QR

Datalogic SpA Hand Held Bluetooth Barcode Scanner 0 GryphonBT QR

Manual

  1   GRYPHON™ BT   Quick Reference
DATALOGIC 2    UK/US USING GRYPHON™ BT SERIES READERS  Gryphon™ BT series readers, together with a Bluetooth® compatible remote device, build a Cordless Reading System for the collection, decoding and transmission of barcoded data.  The Gryphon™ BT (Gryphon™ Bluetooth®) reader is a CCD wireless barcode scanner communicating in the 2.4 GHz ISM band and using the Serial Port Profile (SPP). The Bluetooth® compatible remote device can be a PC, PDA, printer, etc with a built-in Bluetooth® device or with external Bluetooth® adapter (i.e. a Bluetooth® dongle).  Using this Quick Reference Manual, you can initialise and start using Gryphon™ BT reader with its default values. For details about general configuration commands, refer to the Gryphon™ BT Refence Manual on the configuration CD-ROM.  Gryphon™ BT readers automatically scan barcodes at a distance. Simply aim the reader and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code.  READING ANGLE Successful scanning is performed by tilting the reader with respect to the barcode to avoid direct reflections which impair the reading performance, see the figure below. Successful reading is signalled by an audible tone plus a good-read blue spot.   OK  Not Advised  To start using your Gryphon™ BT reading system you must:  1.  Have a compatible remote Bluetooth® device (with built-in Bluetooth® radio or an external Bluetooth® adapter) ready to work. See your Bluetooth® compatible device documentation. 2.  Charge the Gryphon™ BT battery using C-GRYPHON charger as described in this Quick Reference manual. A full charge takes 4 hours with NiMh batteries. 3.  Configure the reader as described in this Quick Reference manual under "Gryphon™ BT Configuration". Good read spot Good read LED
GRYPHON™ BT  3  UK/US CHARGING THE BATTERIES  By placing the reader onto the C-GRYPHON battery charger it is possible to charge the Gryphon™ BT batteries. Make sure the charging LED goes on.  The LEDs positioned on the cradle signal the charge status, as described in the following table:   LED  STATUS  Yellow On = C-GRYPHON is powered. Blinking = C-GRYPHON receives commands from  the Host.  Red  On = the battery charge is in progress.  Green  On = the battery is completely charged.           DISCHARGE  After many recharging cycles NiMh and NiCd batteries may tend to lose their operating autonomy. This condition can be overcome by positioning the Gryphon™ BT onto the C- GRYPHON charger and pressing the “battery reconditioning” button. A discharge cycle may last up to 2 hours. Power on / Data (yellow LED) Battery reconditioning button Charge completed (green LED) Charging (red LED)
DATALOGIC 4    UK/US Changing the Batteries  When the above procedure is no longer effective, the batteries must be changed. To change the batteries of your reader, unscrew the battery cover screw, replace the old batteries with new ones, then insert the cover in the handle and screw it back into place. (See the following figures).        CAUTION Dispose of the batteries as required by the relevant laws in force.   Powering the C-GRYPHON   CAUTION Connections should always be made with power off!  Apply power to C-GRYPHON by connecting a power supply unit to the connector on the base of the battery charger.  C-GRYPHON is ready to charge Gryphon™ BT Series readers with NiMh or NiCd batteries.   C-GRYPHON power supply connector + Power Supply
GRYPHON™ BT  5  UK/US GRYPHON™ BT OPERATION  RADIO CONNECTION  Gryphon™ BT as Slave A Gryphon™ BT is Slave when it sends barcodes to a Master remote Bluetooth® device such as a PC, Laptop, PDA, etc, which has initialized the communication.  Once set as Slave, a Gryphon™ BT reader requires no particular configuration for communication, however some radio parameters can be set to increase system performance and data transmission security, see the Gryphon™ BT Reference Manual on the configuration CD-ROM. At startup the reader can only wait for the Master to initialize the radio communication.  The following is a general procedure recommended for Gryphon™ BT Slave applications: 1.  Power up the remote Bluetooth® Master device (example Laptop or PC). 2.  Power up the Gryphon™ BT reader within radio range (10 meters). Any modifications to the radio configuration should be made at this time before the radio connection takes place. 3.  From the remote Bluetooth® Master device, execute the Discovery procedure, (according to the procedure given in the documentation of the Bluetooth® Master device), to recognize the Gryphon™ BT reader(s) within radio range. 4.  Check that "Gryphon BTx00       " is shown among the discovered devices. 5.  Request to open an SPP connection with Gryphon™ BT, making sure to disable any required PIN and/or pairing parameters. Gryphon™ BT is always discoverable and connectable without any required PIN.   After the Gryphon™ BT reader indicates radio connection (see the Status LED Indicator table), you can start sending barcodes.   If the Master remote Bluetooth® device can support a piconet, the communication can be established with up to 7 seven Slave readers at the same time.
DATALOGIC 6    UK/US Gryphon™ BT as Master A Gryphon™ BT is Master when the remote Bluetooth® device is Slave, i.e. with a Bluetooth® barcode printer. Once set as Master, a Gryphon™ BT reader must be configured to recognize the address of the Slave device to which it wants to communicate.  By default, at startup the reader initializes the communication with the Slave. If the connection is successful, the reader can send barcodes to the Slave device.  If the connection is not successful, you can attempt a connection manually by double-clicking the reader trigger. Radio connections can also be managed manually as described in the Gryphon™ BT Reference Manual on the configuration CD-ROM.   SLEEP STATE The µP in the reader enters a “Sleep” state after 5 minutes of no reading for minimum power consumption.   DATA TRANSMISSION The transmission of data can be transparent (no ACK/NACK protocol), when each character is read and immediately sent to the Host (default value). Otherwise, data transmission can be with flow control (with ACK/NACK protocol), when, after each reading, Gryphon™ BT waits for an acknowledge that the remote Host received the data before reading and sending the following code.   NOTE RTS/CTS handshaking should be set by the Bluetooth® COM driver for correct serial communication. If not used, the RTS line must be forced to the level that doesn't block such communication.   STATUS LED INDICATOR  Blue LED  Meaning 1 blink / 2 sec.  Radio connection 2 blinks / 2 sec.  No radio connection 1 blink / 4 sec.  Sleep state: Radio connection 2 blinks / 4 sec.  Sleep state: No radio connection 1 Blink  Good decoding A long sequence of short blinks  Connection / re-connection attempts For more details and other meanings of the Gryphon™ BT indicators (LED, blue spot and beeper), refer to the Gryphon™ BT Reference Manual on the configuration CD-ROM.
GRYPHON™ BT  7  UK/US GRYPHON™ BT CONFIGURATION  Configure the Gryphon™ BT by choosing one of the two procedures below and reading the codes in the given sequence.   GRYPHON™ BT AS SLAVE   Restore Gryphon™ BT default 1. iPk iPk iPk Set Gryphon™ BT as Slave 2. i25?k i25?k i25?k     YOUR READER IS NOW READY TO BE DISCOVERED (CONNECTED VIA RADIO) BY A BLUETOOTH® MASTER DEVICE AND READ BARCODES.
DATALOGIC 8    UK/US GRYPHON™ BT AS MASTER  Note: for the hexadecimal character selection of step 4, use the table at the end of this manual.  Restore Gryphon™ BT default 1. iPk iPk iPk  Set Gryphon™ BT as Master 2. i25Dk i25Dk i25Dk  Enter configuration 3. ik ik ik  Set Remote Bluetooth® Device Address (slave) 4. i242k i242k i242k  + 12 hexadecimal characters for the remote Bluetooth® device address  Exit and Save configuration 5.  i k i k i k  Request Radio Connection with Slave 6.  i2$gk i2$gk i2$gk   YOUR READER IS NOW CONFIGURED TO READ BARCODES USING THE DEFAULT VALUES.
GRYPHON™ BT  9  UK/US GRYPHON™ BT DEFAULT CONFIGURATION  DATA FORMAT code identifier disabled, field adjustment disabled, code length tx not transmitted, character replacement disabled, address stamping = disabled, address delimiter = disabled. POWER SAVE scan rate 270 scans/s. READING PARAMETERS operating mode hand-held, hardware trigger, trigger active level, no timeout, Flash On = 1 sec, Flash Off = 0.6 sec, one read per cycle, safety time 0.5 sec, beeper intensity high, tone 2, beeper type monotone, beeper length short, good read spot duration medium, beeper control for radio response = ON. DECODING PARAMETERS ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver™ disabled, decoding safety = one read. CODE SELECTION enabled codes  BT200  Code PDF417  EAN 8/EAN 13 / UPC A/UPC E without ADD ON check digit transmitted, no conversions Interleaved 2/5 check digit control and transmission, variable length code; 4-99 characters Standard Code 39 no check digit control, variable length code; 1-99 characters BT100 BT200 Code 128, variable length code; 1-99 characters disabled codes  BT100 BT200 EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, Codablock-A, Codablock-F Standard and EAN, MSI, Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49 RSS family
DATALOGIC 10    UK/US ADVANCED FORMATTING PARAMETERS concatenation disabled, no advanced formats defined, Zebra printer formatting = disabled. RADIO PARAMETERS radio protocol timeout = 3 seconds, transmission retry = none, no ACK/NACK protocol nor frame packing, power-off timeout = 4 hours, user-friendly name = "Gryphon BTx00       ", beeper control for radio response = good decode and good reception, Bluetooth® role = Slave, destination address = 000000000000, auto-connection = enabled, auto-reconnection = enabled.
GRYPHON™ BT  11  UK/US SERIAL CONFIGURATION OPTIONS  In addition to the battery charge function C-GRYPHON can be connected to a PC by means of an RS232 interface to send new configuration strings from the PC to the reader (i.e. using DL Sm@rtSet™), to upgrade application software onto the Gryphon™ BT reader or optionally when performing the copy configuration procedure (see the Gryphon™ BT Reference Manual).   Host interface connector  To proceed with these operations, connect an RS232 cable between  C-GRYPHON and the PC. Connect the power supply to C-GRYPHON. Place the Gryphon™ BT reader onto the charger.   Power Supply RS232 Interface to PC
DATALOGIC 12    UK/US TECHNICAL FEATURES  Electrical Features Battery Type  2 AA NiMh* batteries 1.2 V – 1850 mAh Time of recharge NiMh  4 hours Operating autonomy (typ. continuous reading)  25.000 reads - NiMh Max scan rate  270 scans/sec Indicators  LED, Good Read Spot, Beeper Optical Features Sensor  CCD solid state (3648 pixels) Illuminator LED array Wavelength  630 ~ 670 nm Max. LED Output Power  0.33 mW LED Safety Class  Class 1  EN 60825-1 Reading field  see reading diagram (p.47) Max. resolution  0.076 mm, 3 mils PCS minimum  15% (Datalogic Test Chart) Radio Features Bluetooth® version  Bluetooth® 1.1 Profiles supported  Serial Port Profile Working frequency  2.4000 to 2.4835 GHz Maximum output power  2.5 mW (class 2) Range (in open air)  10 m. Environmental Features Working Temperature  0°to + 40 °C / 32° to 104 °F Storage Temperature (without battery)  -20°to + 70 °C / - 4° to 158 °F Humidity 90% non condensing Drop resistance  IEC 68-2-32 Test ED Protection class  IP30 Mechanical Features Weight (with batteries)  about 280 g. / 9.87 oz Dimensions  179 x 81 x 98 mm / 7.04 x 3.18 x 3.85 in Material  ABS and Polycarbonate molded with rubber  *  It is possible to employ also NiCd or non-chargeable Alkaline AA batteries.
GRYPHON™ BT  13  UK/US C-GRYPHON Electrical Features Supply voltage  9..28 Vdc Power consumption  max. 8 W (charging) * Indicators Battery charging (red) Charge completed (green) Power (yellow) Time of recharge  NiMh / NiCd batteries: 4 hours Environmental Features Working temperature  0° to +40 °C / 32° to 104 °F Storage temperature  -20° to +70 °C / - 4° to 158 °F Humidity  90 % non condensing Protection class  IP30 Communications Interface RS232 Baud Rate  9600 Data Bits  8 Stop Bit  1 Parity None Mechanical Features Weight  about 250 g. / 8.81 oz Dimensions  208 x 107 x 55.5 mm / 8.1 x 4.2 x 2.18 in Material ABS  *  Having a switching regulator inside, the C-GRYPHON draws the same power, regardless of the supply voltage, i.e. as the input voltage increases the current drawn decreases.
DATALOGIC 14    UK/US TROUBLESHOOTING  PROBLEM A beep or a LED blink signals an interruption of the radio communication with the remote Bluetooth® device. SOLUTION •  It is possible that the distance from the remote Bluetooth® device is more than 10 m or that an obstacle interrupted the communication. •  Restart the radio communication.   PROBLEM The reader is Master and is not able to initialize radio communication with the remote Bluetooth® device server. SOLUTION •  Put the reader near the remote Bluetooth® device and try to initialize the radio communication again. •  Make sure that: -  the remote Bluetooth® device is powered; -  the protocol version is compatible with Gryphon™ BT's protocol; -  the remote Bluetooth® device is not yet connected to another BT device with the same SPP. •  Repeat the remote Bluetooth® device address procedure. •  Display Gryphon™ BT configuration by placing the reader on the C-GRYPHON and sending the Transmit Configuration command.
GRYPHON™ BT  15  UK/US PROBLEM The remote Bluetooth® device discovers a Gryphon™ BT within its range of radio communication but is not able to communicate with it. SOLUTION •  Make sure that: -  the remote Bluetooth® device has not any communication protection (i.e. a password); -  the protocol version is compatible with Gryphon™ BT's.   PROBLEM It seems that the Gryphon™ BT radio communication range is less than 10 m. SOLUTION •  Check that there are no obstacles to radio transmission between the devices.
DATALOGIC 16    UK/US SERVICES AND SUPPORT  Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com/services/support and click on the links indicated for further information including: •  Services - Warranty Extensions and Maintenance Agreements •  Support - Software Driver Downloads •  Contact Us - Listing of Datalogic Subsidiaries and Quality Partners •  Authorised Repair Centres •  Products >Hand-Held Readers >Software Tools - DL Sm@rtSet™ DL Sm@rtSet™ is a Windows-based utility program which allows device configuration using a PC. It provides RS232 interface configuration as well as configuration barcode printing.   WARRANTY  Datalogic warranties this product against defects in workmanship and materials, for a period of 24 months from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product, these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.   PATENTS  This product is licensed under one or more of the following U.S. patents: 4,282,425; 4,570,057; 4,766,300; 4,894,523; 5,021,642; 5,038,024; 5,081,343; 5,095,197; 5,144,119; 5,144,121; 5,182,441; 5,187,355; 5,187,356; 5,218,191; 5,233,172; 5,258,606 and /or 5,288,985  This product is covered by one or more of the following patents and patent applications: US 5,917,176; US 5,992,740; US 6,010,073; US pat. Appl. 99US-320.643; US pat. Appl. 99US-362.988; US pat. Appl. 98US-126.606; EP pat. Appl. 00EP-830.127; EP pat. Appl. 00EP-830.122; EP pat. Appl. 98EP-830.336; EP pat. Appl. 98EP-830.611; EP pat. Appl. 97EP-200.317; EP pat. Appl. 97EP-830.408; EP pat. Appl. 96EP-830.473; EP pat. Appl. 96EP-830.660; EP pat. Appl. 96EP-830.439
GRYPHON™ BT  17  UK/US COMPLIANCE  This device must be opened by qualified personnel only. The batteries must be removed before opening the device.  Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.  This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -  Reorient or relocate the receiving antenna. -  Increase the separation between the equipment and receiver. -  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help.  Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventual necessity of a user license. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for further information.     LED CLASS   TO EN60825-1:(2001)
DATALOGIC 18    UK/US GRYPHON™ BT SERIES GRYPHON BT100 (STANDARD) 0 5 10 15 20 25 30 35-15-10-5051015M100 (STD) -  Reading Zones  (10° skew angle)(cm)CODE 390.13 mm(5 mils)EAN13 M=10.33 mm(13 mils)CODE 390.50 mm(20 mils)CODE 390.076 mm(3 mils)0.13 mm(5 mils)  GRYPHON BT200 (PDF) 0 5 10 15 20 25 30 35-10-50510M200 (PDF) -  Reading Zones  (10° skew angle)(cm)CODE390.076 mm(3 mils)CODE390.13 mm(5 mils)EAN13 M=10.33 mm(13 mils)CODE390.50 mm(20 mils)0.13 mm(5 mils)  0 2 4 6 8 10 12 14 16-8-6-4-202468(cm)M200 (PDF) - PDF417 codes, Reading Zones  (10° skew angle)PDF417 Aspect Ratio 3:10.25 mm(10mils)0.17 mm(6.6mils)0.38 mm(15mils)
GRYPHON™ BT  19  UK/US HEX NUMERIC TABLE  ik ik ik   ik ik ik  0  1    ik ik ik   ik ik ik  2  3    ik ik ik   ik ik ik  4  5    ik ik ik   ik ik ik  6  7    ik ik ik   ik ik ik  8  9    i"#k i"#k i"#k   i#$k i#$k i#$k  A   B    i$%k i$%k i$%k   i%&k i%&k i%&k  C   D    i&'k i&'k i&'k   i'(k i'(k i'(k  E   F
     03 DATALOGC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el  GRYPHON BT100, Cordless bar code reader GRYPHON BT200, Cordless bar code reader    e tutti i suoi modelli   and all its models   et tous ses modèles   und seine modelle   y todos sus modelos  sono conformi alla Direttiva del Consiglio Europeo sottoelencata: are in conformity with the requirements of the European Council Directive listed below: sont conformes aux spécifications de la Directive de l'Union Européenne ci-dessous: der nachstehenden angeführten Direktive des Europäischen Rats entsprechen: cumple con los requisitos de la Directiva del Consejo Europeo, según la lista siguiente: 1999/5/EEC R&TTE  Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:   EN 60950-1, December 2001: INFORMATION TECHNOLOGY EQUIPMENT – SAFETY –  PART 1: GENERAL REQUIREMENTS  ETSI EN 300 328-2, December 2001: ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2.4 GHZ  ISM  BAND AND USING SPREAD SPECTRUM MODULATION TECHNIQUES; PART  2: HARMONIZED  EN  COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R & TTE DIRECTIVE  ETSI EN 301 489-17, September 2000: ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILTY (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART  17: SPECIFIC CONDITIONS FOR WIDEBAND DATA AND HIPERLAN EQUIPMENT        Lippo di Calderaia, 14.01.04  Ruggero Cacioppo   Quality Assurance Manager

Navigation menu