DT Research 800G Medical Cart Computer User Manual DT59X users manual for FCCCE

DT Research, Inc. Medical Cart Computer DT59X users manual for FCCCE

User Manual

DT590B/ DT592B/DT594B BASIC OPERATION GUIDE      ENGLISH   INTRODUCTION Thank you for acquiring DT Research’s medical cart computer medical cart computer. With a 19-inch, 22-inch or 24-inch TFT display and powered by the Intel Core™ i7 processor, the medical cart computer offers optimal combinations of performance and power savings. With fully-integrated point-of-care modules within an elegant, space-saving design, the medical cart computer is the optimum solution to enhance workflow and service. Please take a few moments to review the contents of this document to ensure that the setup and startup proceed smoothly. The medical cart computer medical cart computer is ready for use, out of the box, in its default configuration when powered by the power source provided. The following discussion offers guidance on the hardware elements and features of the computer. Please refer to your device provider for information pertaining to the software operating system or software applications.  Package Contents One DT590B, DT592B or DT594B Three DR202 Li-ion batteries (optional) AC-DC power adapter with power cord Basic operation guide      DT590B/ DT592B/ DT594B
I/O Ports: The medical cart computer has a comprehensive set of I/O ports. The following ports are located along the lower rear edge of the display unit.  Cleaning the Screen: • A screen cleaning solution that is non-alcohol and non-abrasive can be used to clean the touch screen. • We suggest cleaning with a micro-fiber cloth. • Please spread the solution on to the cloth and then clean the touch screen.Cleaning the Anti-microbial Enclosure: •Useasoft/non‐abrasiveclothmoistenedwithwatertocleantheenclosure.•Ifusingacleaner,analcohol‐freeandoxide‐freecleaningliquidisrecommended.•Topreventscratchingtheanti‐microbialcoating,pleasewipegently.ENGLISH    2  DT590B/ DT592B/ DT594B
Precautions: Always exercise care when operating • and handling the medical cart computer. • Never disassemble any portion of the enclosure, as this will void any product warranty on the medical cart computer.• Do not use any AC/DC adapter other than the one provided with the device or a replacement acquired from the manufacturer. • In the unlikely event that smoke, abnormal noise or strange odor is present, immediately power down the medical cart computer and disconnect all power sources. Please report the problem to your device provider immediately.   Basic Features  The medical cart computer integrates a bright 19”, 22” or 24” display with optional capicitive touch, USB ports, and is complemented by a smart card reader option for comprehensive point-of-care applications.  Powering ON and OFF If your medical cart computer comes with the battery packs, please open the battery slot caps and then put in the battery packs one by one. If not, please use the AC-DC adapter with the medical cart computer for the power supply. To activate the medical cart computer, push and quickly release the Power Button and the display will come on in a few seconds. To put in Standby mode, push and quickly release the Power Button. To turn off for extended storage, power off the device safely using any software function that “shuts down computer” provided in the software operating system.  NOTE: The battery packs shipped with your device may be low in power—please use the AC-DC adapter with the medical cart computer when setting up the device for the first time to fully charge the internal battery packs.   NOTE: When the battery pack(s) is (are) charging, the blue-colored Battery LED should blink slowly. If plugging in the AC-DC adapter does not trigger this blinking activity and the LED stays dark, the battery pack(s) may have been drained substantially. Try unplugging/ replugging the AC-DC adapter to the medical cart computer a few times to activate the charging process.  NOTE: To conserve power, use (push and quick release) the Power Button to put the device in “Standby”mode while not in use. Pushing briefly on the same button will wake up the system within seconds.  NOTE: Avoid using the Power Button (“hold 4+ seconds” feature) to turn off the device—this form of hardware shutdown is intended to be a means of recovery from device lockups, and not as normal operation.    ENGLISH    3DT590B/ DT592B/ DT594B
Power/Battery LED Status • Blue indicates the battery is 25% to 100% charged • Blinking blue indicates the battery is charging • Orange indicates that the battery is between 11% to 25% • Blinking Orange indicates that the battery is below 10% Wireless Networking Wireless LAN The medical cart computer is often delivered with an embedded (user-inaccessible) 802.11ac WLAN adapter equipped with a hidden custom antenna. • Through the support of typical WLAN adapters, the medical cart computer should be able to detect all 802.11 access points in the vicinity for you to select the access point of your choice for connection. • The SSID and WEP/WPA/WPA2 (if enabled) parameters on the medical cart computer and the access points have to match. The SSID is case-sensitive and it is recommended that you enable WEP/WPA/WPA2 encryption (or advanced alternatives) for secure access. • When WEP/WPA/WPA2 is enabled, you may need to consult your network administrator or your networking equipment literature to properly configure associated settings such as Authentication mode, etc. • Refer to the access point operating manuals for setting up the 802.11 access points.  Bluetooth The medical cart computer features a built-in Bluetooth adapter that operates on the Microsoft Windows Bluetooth protocol. The Bluetooth configuration application is invoked from the System Tray or from the Control Panel. Follow the instructions and options provided within the application to configure and invoke Bluetooth connectivity with the corresponding peripherals.  NOTE: Bluetooth devices or accessories that are not compatible with the Microsoft Windows Bluetooth protocol may not work with the medical cart computer.   ENGLISH    4  DT590B/ DT592B/ DT594B
SPECIFICATIONS:  Iten  DT590B DT592B  DT594B  CPU Intel® Core™ i7, 2.4GHz  Intel® Core™ i7, 2.4GHz  Intel® Core™ i7, 2.4GHz   RAM 4GB to 16GB  4GB to 16GB  4GB to 16GB Storage 64GB to 256GB Flash  64GB to 256GB Flash  64GB to 256GB Flash Operating System Microsoft® Windows® 7 Professional 或Windows® 8.1 Pro Industry Display 19" TFT-LCD  21.5" TFT-LCD  23.6" TFT-LCD Display Resolution 1280 X 1024  1920 X 1080  1920 X 1080 Touch Screen Optional capacitive touch  Optional capacitive touch  Optional capacitive touch Network Interface Ethernet 10/ 100/ 1000 MB Base-T LAN; Wi-Fi 802.11ac, 2.4GHz/ 5GHz dual band; Bluetooth Bluetooth 4.0 LE  Bluetooth 4.0 LE  Bluetooth 4.0 LE Control Buttons 5 side buttons: 1 power and 4 functional buttons 5 side buttons: 1 power and 4 functional buttons 5 side buttons: 1 power and 4 functional buttons Speaker  Built-in speaker  Built-in speaker  Built-in speaker I/O Ports USB Port  2 (USB 2.0),4 (USB 3.0)  2 (USB 2.0),4 (USB 3.0)  2 (USB 2.0),4 (USB 3.0) COM Port  1 4 4 HDMI (1.4a)  2 2 2 Microphone-in  1 1 1 Audio-out  1 1 1 Ethernet  RJ45 connector for Ethernet x 1  RJ45 connector for Ethernet x 1  RJ45 connector for Ethernet x 1 DC-in  1 1 1 Mechanical and Environmental Battery Pack  DR202 Li-ion battery; 10.9V, 7800mA x 3 (optional) DR202 Li-ion battery; 10.9V, 7800mA x 3 (optional) DR202 Li-ion battery; 10.9V, 7800mA x 3 (optional) AC/DC Adapter  Input: 100 – 240V AC;   Output: 19V DC, 6.31A Input: 100 – 240V AC;   Output: 19V DC, 6.31A Input: 100 – 240V AC;   Output: 19V DC, 6.31A Enclosure  ABS + PC plastics, anti-microbial plastics ABS + PC plastics, anti-microbial plastics ABS + PC plastics, anti-microbial plasticsDimensions   (H x W x D)  14.9 x 17.7 x 2.2 in/ 380 x 450 x 65mm  12.5 x 20.8 x 2.3 in/ 318 x 529 x 58 mm  14.2 x 22.9 x 2.3 in/ 361 x 582 x 57 mmWeight  15.4 lbs/ 7kg  14.3 lbs/ 6.5 kg  20.5 lbs/ 9.3 kg Temperature  Operation: 0°C – 40°C; Storage: -20°C – 60°C Humidity  0% – 90% non-condensing     DT Research, Inc. 2000 Concourse Drive, San Jose, CA 95131   http://www.dtresearch.cn Copyright © 2015, DT Research, Inc. All Rights Reserved.      ENGLISH    5 BOG08241559XEN
FCCRegulations:Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.ThisdevicehasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiatedradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallationIfthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:‐Reorientorrelocatethereceivingantenna.‐Increasetheseparationbetweentheequipmentandreceiver.‐Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.‐Consultthedealeroranexperiencedradio/TVtechnicianforhelp.Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser‘sauthoritytooperatetheequipment.
RFExposureWarningThisequipmentmustbeinstalledandoperatedinaccordancewithprovidedinstructionsandtheantenna(s)usedforthistransmittermustbeinstalledtoprovideaseparationdistanceofatleast20cmfromallpersonsandmustnotbeco‐locatedoroperatinginconjunctionwithanyotherantennaortransmitter.End‐usersandinstallersmustbeprovidewithantennainstallationinstructionsandtransmitteroperatingconditionsforsatisfyingRFexposurecompliance.