COPYRIGHT ©  2005 TERAOKA WEIGH-SYSTEM PTE LTD                    USER MANUAL   WIRELESS RF DEVICE        RF_CC2541 Module EXT TRK-RF-06  REVISION 1.0
    Table of Content  i) Notice .............................................................................................................................. 1 ii) Safety Information ........................................................................................................... 2 iii) Safety Regulations .......................................................................................................... 3 1. General ..............................................................................................................................................................7 1.1 Product Features ............................................................................................................. 7 1.2 Operating Specification ................................................................................................... 7 2 Dimension ....................................................................................................................... 8 3. Label Information ............................................................................................................. 8 4. Interface .......................................................................................................................... 9 5.       Revision Records ......................................................................................................................................... 10
  - 1 -  i)  Notice   DIGI®   The material contained in this document is proprietary and for information only and is subject to change without notice. Teraoka Weigh-System assumes no responsibility for any errors or damages arising from misinterpretation of any procedure. Screen displays, operating procedures and supporting features might vary with different software version releases. This document shall not be reproduced whether in part or whole without the written consent from Teraoka Weigh-System Pte Ltd.                          Teraoka Weigh-System Pte Ltd 4, Leng Kee Road #06-01 SIS Building Singapore 159088
TRK-RF-06 User Manual  2 ii)  Safety Information The operator of the equipment shall comply with the safety and warning indications and procedures outlined in this document. Teraoka Weigh-System Pte Ltd assumes no responsibility or liability for failure to comply with these requirements.   For continued protection against fire hazard replace only with battery of same rating and type.  Avoid overloading the product beyond its rated maximum capacity  Trained and qualified personnel shall only carry out repair and servicing of product.      Disclaimer:  Specifications are subject to change without notice. All dimensions shown are approximate. Please be aware that Teraoka has indicated that its hardware and software used in the product may require additional updates in the future as our product is continually under development. The need for such updates most likely applies to the Printer software.
TRK-RF-06 User Manual  3    iii)  Safety Regulations   Federal Communication Commission Interference Statement  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful interference  in  a  residential  installation.  This  equipment  generates,  uses  and  can  radiate  radio  frequency energy and, if not installed and used in  accordance with the instructions, may cause harmful interference  to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,  which  can  be  determined  by  turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try  to correct the interference by one of the following measures:  - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This  device  may not cause  harmful  interference,  and  (2)  this device must  accept any interference  received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.   IMPORTANT NOTE:  FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.   This device is intended only for OEM integrators under the following conditions:  1)  The antenna must be installed such that 20 cm is maintained between the antenna and users, and  2)   The transmitter module may not be co-located with any other transmitter or antenna,  As long as condition above are met, further transmitter test will not be required. However, the OEM integrator is still  responsible  for  testing  their  end-product  for  any  additional  compliance  requirements  required  with  this module installed (for example, digital device emissions, PC peripheral requirements, etc.).  IMPORTANT  NOTE: In  the  event  that  these  conditions  do  not  be  met  (for  example  certain  laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC  ID could not be used on the final product.  In these circumstances, the OEM integrator  will  be responsible  for  re-evaluating  the  end  product  (including  the  transmitter)  and  obtaining  a  separate  FCC authorization.  End Product Labeling The final end product must be labeled in a visible area with the following: “Contains FCC ID: SUFTRKRF06”.  Manual Information To the End User The  OEM  integrator  has  to  be  aware  not  to  provide  information  to  the  end  user regarding  how  to  install  or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.
TRK-RF-06 User Manual  4 Canada Regulatory Wireless Notice: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:    1) This device may not cause interference and 2) This device must accept any interference, including interference that may cause undesired     operation of the device  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :  1)  le dispositif ne doit pas produire de brouillage préjudiciable, et  2)  ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable  IC Radiation Exposure Statement: This  equipment  complies  with  IC  radiation  exposure  limits  set  forth  for  an  uncontrolled  environment.  This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.   Déclaration d'exposition aux radiations:  Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.  This device is intended only for OEM integrators under the following conditions:  1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and  2) The transmitter module may not be co-located with any other transmitter or antenna.   As long as condition above are met, further transmitter test will not be required. However, the OEM integrator is still  responsible  for  testing  their  end-product  for  any  additional  compliance  requirements  required  with  this module installed (for example, digital device emissions, PC peripheral requirements, etc.).  Cet appareil est conçu uniquement pour les intégrateurs OEM dans les conditions suivantes: (Pour utilisation de dispositif module)  1) L'antenne  doit  être  installée de telle sorte  qu'une  distance  de 20  cm est respectée  entre  l'antenne et les utilisateurs,et  2) Le module émetteur peut ne pas être coïmplanté avec un autre émetteur ou antenne.  Tant que les condition ci-dessus sont remplies, des essais supplémentaires sur l'émetteur ne seront pas nécessaires. Toutefois, l'intégrateur OEM est toujours responsable des essais sur son produit final pour toutes exigences de conformité supplémentaires requis pour ce module installé  IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the IC authorization is no longer considered valid and the IC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate IC authorization.  NOTE IMPORTANTE: Dans le cas où ces conditions ne peuvent être satisfaites (par exemple pour certaines configurations d'ordinateur portable ou de certaines co-localisation avec un autre émetteur), l'autorisation du Canada n'est plus considéré comme valide et l'ID IC ne peut pas être utilisé sur le produit final. Dans ces circonstances, l'intégrateur OEM sera chargé de réévaluer le produit final (y compris l'émetteur) et l'obtention d'une autorisation distincte au Canada.
TRK-RF-06 User Manual  5  End Product Labeling The final end product must be labeled in a visible area with the following: “Contains IC:5663A-TRKRF06”.  Plaque signalétique du produit final Le produit final doit être étiqueté dans un endroit visible avec l'inscription suivante: "Contient des IC:  5663A-TRKRF06".  Manual Information To the End User The  OEM  integrator  has  to  be  aware  not  to  provide  information  to  the  end  user regarding  how  to  install  or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.  Manuel d'information à l'utilisateur final L'intégrateur OEM doit être conscient de ne pas fournir des informations à l'utilisateur final quant à la façon d'installer ou de supprimer ce module RF dans le manuel de l'utilisateur du produit final qui intègre ce module. Le manuel de l'utilisateur final doit inclure toutes les informations réglementaires requises et avertissements comme indiqué dans ce manuel.
TRK-RF-06 User Manual  6 For Taiwan 警語:   第十二條   經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。   第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。  IMPORTANT NOTE: 1. 本模組於取得認證後將依規定於模組本體標示審驗合格標籤 2. 系統廠商應於平台上標示「本產品內含射頻模組:  CCXXXXYYyyyZzW」字樣
TRK-RF-06 User Manual  7 1.  General  The module design is based on RF transceiver with integrated MCU core, CC2541. It implements a proprietary communications  protocol  streamlined  to  lower  cost  and  power  consumption.  The  antenna  used  is  a  PCB antenna. The module will be FCC and TELEC certified for fast and simple integration into end applications. This module may be integrated into a wireless application that operates in 2.4G ISM frequency band.  1.1  Product Features    Model : TRK-RF-06 (RF_CC2541 Module EXT)    Dimension (in mm) : 20.0(L) X 19.0(W) X 4.0(H)    RF Standard : FCC, NCC, IC  TELEC     Modulation : GFSK    Frequency Band : 2.402 GHz – 2.480 GHz    Channel list  : 79 Channels at 1MHz step 2402MHz +(n-1)MHz where n = 1 to 79    Radio Range : Up to 100m, L.O.S     Transmit Power (EIRP) : 11.83dBm (max)    Receiver Sensitivity : -90dBm (typical), PER = 1%     General purpose I/O : 36     1.2  Operating Specification   Voltage : DC 3.0V     Current : 100mA TX mode,     Operating Temperature : -20 °C to 40 °C     Storage Temperature : -40 to +85° C     Humidity : 95% max non condensing
TRK-RF-06 User Manual  8 2  Dimension      3.  Label Information
TRK-RF-06 User Manual  9  4.  Interface     Interface pin assignments   1 VDD 25 P0_3 2 VDD 26 P0_2 3 GND 27 P0_1 4 GND 28 P0_0 5 GND 29 RESET_N 6 GND 30 GND 7 DC 31 GND 8 DD 32 P1_4 9 P2_0 33 P1_5 10 P1_7 34 P1_6 11 GND 35 P2_3 12 GND 36 P2_4 13 SCL   14 SDA   15 GND   16 P1_3   17 P1_2   18 P1_1   19 P1_0   20 GND   21 GND   22 P0_6   23 P0_5   24 P0_4         Notes:   1.  The I/O pins is connected to the external interface port directly.  2.  The voltage level is TTL high/low voltage level.
TRK-RF-06 User Manual  10 5.       Revision Records  Serial No. Date Edition Status Description of Changes Software Version Remarks 1 02/09/2013 1.0 INITIAL RELEASE   2 16/10/2013 1.1 UPDATE FCC ID AND IC ID   3 31/10/2013 1.1 UPDATE THE CANADA STATEMENT DUE TO  >10mW