DCH-Z110/Z120                            The sensor DCH-Z110/Z120 have PIR or door/window integrated with,temperature   and   illumination,  which   are  3  sensors   function   in   one,based on Z-WaveTM technology.It is the Z-WaveTM plus product, it supports  the security, OTA... Thosenewest  features of  the  Z-WaveTM  technology.  Z-WaveTM  is  a  wirelesscommunication protocol designed for home automation, specifically toremotely   control   applications   in   residential   and   light   commercialenvironments. The technology uses a low-power RF radio embedded orretrofitted into home electronics devices and systems, such as lighting,home access control, entertainment systems and household appliances.This product can be included and operated in any Z-WaveTM  networkwith other Z-WaveTM certified devices from other manufacturers and/orother applications.  All non-battery operated nodes within the networkwill act as repeaters regardless of vendor to increase reliability of thenetwork.The device adopt the Z-WaveTM  500 series chip, when your Z-WaveTMnetwork   system   is   all   made   by   Z-WaveTM  500   series   devices.   Thenetwork system will have the advantages as below.•Concurrent multi-channel support reduces external interference.•Better RF range, improve about 10 meters in indoor.•Support 100 Kbps transmit speed, speed up communication.Function Compare DCH-Z110/DCH-Z120PIR Door/Window Temperature IlluminationDCH-Z110 V V VDCH-Z120 V V VAdd to/Remove from Z-WaveTM NetworkThere  are  two  tamper  keys  in  the  device,  one is  in  the  back  side,another is in the front side.  Both of them  can add, remove, reset orassociation from Z-WaveTM network.In the first time, add the device into the Z-WaveTM network.  First, make sure the primary controller is in the add mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.1
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”.  Excluding a node ID allocated by Z-WaveTM  Controller means “Remove” or “Exclusion”.Function DescriptionAdd1.Have Z-WaveTM Controller entered inclusion mode.2.Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.3.After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.Remove1.Have Z-WaveTM Controller entered exclusion mode.2.Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.Node ID has been excluded.ResetNotice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1.Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.2.After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful,the LED will light ON one second. Otherwise, the LED will flash once.3.IDs are excluded and all settings will reset to factory default.Association 1.Have Z-WaveTM Controller entered association mode.2.Pressing tamper key three times within 1.5 seconds to enter the association mode.Note: The device support 2 groups. The group 1 is for receiving the report message, like triggered event, temperature, illumination etc. The group 2 is for light control, the device will send the “Basic Set” command to this group. And each group support 8 nodes maximum.•Failed or success in add/remove the node ID can be viewed from Z-WaveTM Controller.Notice 1: Always RESET a Z-WaveTM device before trying to add it to a Z-WaveTM networkNotice 2: When the device into NWI mode, the sensor functionality will useless. The NWI mode will timeout after 30 seconds. You can press the tamper key 3 times to abort the NWI mode.Z-WaveTM NotificationAfter the device adding to the network, it will wake-up once per day indefault. When it wake-up it will broadcast the “Wake Up Notification”message   to   the   network,   and   wake-up   10   seconds   for   receive  thesetting commands.The wake-up interval minimum setting is 30 minutes, and maximumsetting is 120 hours. And the interval step is 30 minutes.If the user want to wake-up the device immediately, please remove thefront cover, and press the tamper key once. The device will wake-up 10seconds.Z-WaveTM Message ReportWhen  the  PIR  motion  triggered  or   the  door/windows  triggered,  thedevice will report the trigger event and also report the battery status,temperature and illumination level.In default  the  device  will using  Notification  Report to  represent  thetrigger event, it can be changed to Sensor Binary Report by setting theconfiguration NO. 7 Bit4 to 1.2
* Motion Report:When the PIR motion detected, the device will unsolicited to send thereport to the nodes in the group 1.Notification Report (V4)Notification Type: Home Security (0x07)Event: Motion Detection, Unknown Location (0x08)Sensor Binary Report (V2)Sensor Type: Motion (0x0C)Sensor Value: 0xFF* Door/Window Report:When the door/window state changed, the device will unsolicited tosend the report to the nodes in the group 1.Notification Report (V4)Notification Type: Access Control (0x06)Event: Door/Window is open (0x16)          Door/Window is closed (0x17)Sensor Binary Report (V2)Sensor Type: Door/Window (0x0A)Sensor Value: 0x00 is closed, 0xFF is opened.* Tamper Report:Both the 2 tamper keys are pressed over 5 seconds. The device willinto the alarm state. In that state, if any one of the tamper keys bereleased, the device will unsolicited to send the report to the nodes inthe group 1.Notification Report (V4)Notification Type: Home Security (0x07)Event: Tampering. Product covering removed (0x03)Sensor Binary Report (V2)Sensor Type: Tamper (0x08)Sensor Value: 0xFF* Temperature Report:When the PIR motion detected or the door/window state changed, thedevice will  unsolicited to  send the  “Sensor Multilevel  Report”  to thenodes in the group 1.Sensor Type: Temperature (0x01)Note: To disable this functionality by setting the configuration N0.5 bit5to 1.*** Temperature differential report ***This function default is enabled, to disable this function by setting theconfiguration NO.21 to 0.In the default, when the temperature is changed to plus or minus onedegree   Fahrenheit   (0.56   degree   Celsius),   the   device   will   reporttemperature information to the nodes in the group 1.The device will measure the temperature in every one minute. And ifthe temperature is over 140 degree Fahrenheit (60 degree Celsius), thedevice will always report in each measurement.Caution 1: Enable this functionality, it will cause the PIR Motion to disable detection when the temperature measurement. In other words,The PIR motion will blind one second in every one minute.* Illumination Report:When the PIR motion detected or the door/window state changed, thedevice will  unsolicited to  send the  “Sensor Multilevel  Report”  to thenodes in the group 1.Sensor Type: Luminance (0x03)Note:  To  disable   this  functionality  by  setting  the   configuration   N0.5bit4 to 1.*** Illumination differential report ***3
This function default is disabled, to enable this function by setting theconfiguration NO.22 not to zero.Enable   this  functionality,  the  device  will  measure  the  illumination  inevery one minute. And if the illumination is changed to plus or minusthe value (setting by the configuration NO.22), the device will reportillumination information to the nodes in the group 1.Caution 1: Enable this function will reduce the battery life about 15% ~ 20%. And another issue is setting the differential value too small, it will cause report too frequency, shorter the battery life more.Propose the setting differential value should not small than 10.Caution 2: If the configuration No.4 is setting to 0 or 100, this functionality is useless.Caution 3: Enable this functionality, it will cause the PIR Motion to disable detection when the illumination measurement. In other words, The PIR motion will blind one second in every one minute.* Timing Report:Beside   the   event   triggered   could   report   message,   the   device   alsosupport the timing unsolicited report of the status.•Battery level report: Every 6 hours report once in default.It could be changed by setting the configuration NO. 10.•Low   battery   report:   When   the   battery   level   is   too   low,   every   30minutes will report once.•Door/window state report: Every 6 hours report once in default.It could be changed by setting the configuration NO. 11.•Illumination level report: Every 6 hours report once in default.It could be changed by setting the configuration NO. 12.•Temperature report: Every 6 hours report once in default.It could be changed by setting the configuration NO. 13.Notice:  The configuration NO. 10, 11, 12 and 13 could be setting tozero to disable the auto report. And  the configuration NO. 20 couldchange the tick interval, the default value is 30, if setting to 1, thatmeans the minimum auto report interval will be one minute. And pleasenotice if setting this value to zero, that means disable all of the timingreport except the low battery detection.Power Up Procedure* Battery Power CheckWhen the device power up, the device will detect the power level of thebattery immediately. If the power level is too low, the LED will continueflash about 5 seconds. Please change another new battery.* PIR Warm UpWhen   the   device   power   on,   the   PIR   need   to   warm   up   before   theoperation. The warm up time about   1  minute, the LED will flash  inevery 2 seconds. After finish the procedure the LED will light ON threetimes.* NWIWhen the device power on, the device will check is it already adding tothe network? If doesn't, it will auto start the NWI mode. The LED willflash in every second and continue 30 seconds. Until timeout or thedevice successful to inclusion by controller. The use can presses thetamper key 3 times to abort the NWI mode.* WakeWhen the device power on, the device will wake about 20 seconds. Inthis duration, the controller can communicate with the device. Normallythe device is always sleeping to save the battery energy.Over The Air (OTA) Firmware UpdateThe device supports the Z-Wave firmware update via OTA.Before starting the procedure, please remove the front cover of thedevice. Otherwise the hardware check will be failed.Let the controller into the firmware update mode, and then press thefront tamper key once to start the update.4
After finish the firmware download, the LED will start flash in every 0.5second. At that time, please don't remove the battery, otherwise itwill cause the firmware broken, and the device will no function.After the LED stop flash, it is recommended that the user power up thedevice.  Caution:   After   remove   the   battery,   please   wait   about   30seconds, and then re-install the battery.Security NetworkThe device supports  the security function. When the device includedwith a security controller, the device will auto switch to the securitymode. In the security mode, the follow commands need using SecurityCC wrapped to communicate, otherwise it will not response.COMMAND_CLASS_BATTERYCOMMAND_CLASS_NOTIFICATION_V4COMMAND_CLASS_ASSOCIATION_V2COMMAND_CLASS_CONFIGURATIONCOMMAND_CLASS_SENSOR_BINARY_V2COMMAND_CLASS_SENSOR_MULTILEVEL_V5COMMAND_CLASS_WAKE_UP_V2Operation ModeThere are two modes “Test” and “Normal”. “Test Mode” is for the user test the sensor function when installation.“Normal Mode” for the normal operation.When the event triggered, normally the LED won't indicated, unless thebattery is in the low level, the LED will flash once. But in the “TestMode” the LED also will light ON one second.When the event triggered, the device will report the messages to thenodes in the group 1. The messages also include the battery level, thetemperature and the illumination level. The user can switch the reportby   setting   the   configuration   NO.   5   bit4   (illumination)   and   bit5(temperature), and the configuration NO. 7 bit6 (battery).When the event triggered, if the environment luminance is less thanthe setting of the value of the configuration NO. 4, the device will emitthe signal to turn ON the lighting equipment, those nodes are in thegroup 2. And delay a while to turn OFF the lighting equipment. Thedelay time is setting by the configuration NO. 9.The  PIR  motion   re-detected  interval,  in  the  “Test   Mode”  fixed  to  6seconds.   In   the   “Normal   Mode”,   it   according   to   the   setting   of   theconfiguration NO. 8.Notice: When the tamper key of the back side is released, the devicealways in the “Test Mode”.5
6
Battery InstallationWhen   the   device  report  the   low  battery  message.   The  user  shouldreplace the battery to new one. The battery type is CR123A, 3.0V.The way to open the front cover please follow below steps.1.Using a tool to press the 1-1 position, to release the cover.2.Hold the front cover and pull back3.Hold the front cover and pull upReplace the new battery and install the cover back.1.Put the front cover bottom to 1-1, and press down.2.Push the front cover top to 2-1.Choosing a Suitable Location1.The recommended mounting height is 160cm for DCH-Z120.2.Don't let the device facing the window or the sunlight.3.Don't let the device facing the source of heat. For instance the heateror the air-condition.7
Installation1. In the first time, add the device into the Z-WaveTM network.  First,make sure the primary controller is in the inclusion mode. And thenpower on the device, just take out the insulation Mylar in the back sideof   the   device.   The   device   will   auto   start   the   NWI   (Network   WideInclusion) mode. And it should be included in 5 seconds. You will seethe LED light ON one second.2. Let the controller associate with the device into the first group, anylight switch that intend to be turned on when the device trig pleaseassociate with the device into the second group.3. In the accessory pack. There are two types of double coated tape,one is thicker (hereinafter referred to as A tape)  and another is thinner(hereinafter referred to as B tape), you can use A tape for the test atthe beginning. The right way for A tape installation is stick it to theposition below tamper key. The thicker tape won't let the tamper keypressed,   so   the   sensor   will   enter   the   test   mode,   You   may   test   ifinstalled position is good or not by this way.After finish the test and decide to fix, then you can remove tape A, andmounting the sensor by using tape B. The tamper key will pressed andlet the sensor enter normal mode.Z-Wave Configuration SettingsNotice:* All of the configuration, the data size is 1.* The configuration mark with star(*), means after the remove the setting stillkeep,   don't reset  to  factory   default. Unless  the   user   execute  the   “RESET”procedure.* The reserve bit or not supported bit is allowed any value, but no effect.8
NO. Name Def. Valid A B Description2Basic Set Level 0xFF All  Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength.0 means turn off the light.3(*)PIR Sensitivity 80 0 ~99  PIR sensitivity settings.0 means disable the PIR motion.1 means the lowest sensitivity,99 means the highest sensitivity.High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency.4Light Threshold 99 0 ~100  Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light.0 means turn off illumination detected function. And never turn on the light.1 means darkest.99 means brightest.100 means turn off illumination detected function. And always turn on the light.Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.NO. Name Def. Valid A B DescriptionNO. Name Def. Valid A B Description5(*)OperationMode0All Operation mode. Using bit to control.0  Bit0: Reserve.0 Bit1: 1 means test mode,         0 means normal mode.Notice:This bit only effect by the DIP Switch setting to “customer mode”, otherwise it decides by DIP Switch setting to Testor Normal Mode.0  Bit2: Disable the door/window function.  (1:Disable, 0:Enable)0  Bit3: Setting the temperature scale.  0: Fahrenheit, 1:Celsius0  Bit4: Disable the illumination report after event triggered.  (1:Disable, 0:Enable)0  Bit5: Disable the temperature report after event triggered.  (1:Disable, 0:Enable)0  Bit6: Reserve.0  Bit7: Disable the back key release into test mode.  (1:Disable, 0:Enable)NO. Name Def. Valid A B Description9
NO. Name Def. Valid A B Description6(*)Mult-Sensor Function Switch4All Multisensor function switch. Using bit to control.0 Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)0 Bit1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)1 Bit2: Disable magnetic integrate PIR  to turn ON the lighting nodes in the association group 2.  (1:Disable, 0:Enable) (Default is Disable)0 Bit3: When Bit2 is 0 (Enable), Are the device and the lighting in the same room?  0: In the same room(Default),  1: In the different room.Notice: If this bit is 1, it is recommended also set the Bit1 to 1, cause    the PIR triggered, doesn't mean the people in that room.0  Bit4: Disable delay 5 seconds to turn off the light, when door/window closed.  (1:Disable, 0:Enable)0  Bit5: Disable auto turn off the light, after door/window opened to turn on the light.  (1:Disable, 0:Enable)Notice: If bit2 is zero, this setting is useless.Notice: If the configuration No.9 is zero, this setting is useless.0  Bit6: Reserve.0  Bit7: Reserve.NO. Name Def. Valid A B DescriptionNO. Name Def. Valid A B Description7(*)CustomerFunction 4All Customer function switch, using bit control.0  Bit0: Reserve.0 Bit1: Enable sending motion OFF report.  (0:Disable, 1:Enable)Note: Depends on the Bit4,0: Report Notification CC,Type: 0x07, Event: 0xFE1: Sensor Binary Report,Type: 0x0C, Value: 0x001  Bit2: Enable PIR super sensitivity mode. (0:Disable, 1:Enable)0  Bit3: Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable)0  Bit4: Notification Type,          0: Using Notification Report.        1: Using Sensor Binary Report.0  Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable)0  Bit6: Disable to report battery state when the device triggered. (1:Disable, 10
0:Enable)0  Bit7: Reserve.NO. Name Def. Valid A B Description8PIR Re-Detect Interval Time31 ~127  In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds).Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy.Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting.9Turn Off Light Time40 ~127  After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32seconds).0 means never send turn off light command.10Auto Report Battery Time12 0 ~127  The interval time for auto report the battery level.0 means turn off auto report battery.The default value is 12. The tick time can setting by the configuration No.20.11 Auto ReportDoor/Window State Time12 0 ~127  The interval time for auto report the door/window state.0 means turn off auto report door/window state.The default value is 12. The tick time can setting by the configuration No.20.NO. Name Def. Valid A B DescriptionNO. Name Def. Valid A B Description12Auto ReportIlluminationTime12 0 ~127  The interval time for auto report the illumination.0 means turn off auto report illumination.The default value is 12. The tick time can setting by the configuration No.20.13Auto ReportTemperature Time12 0 ~127  The interval time for auto report the temperature.0 means turn off auto report temperature.The default value is 12. The tick time can setting by the configuration No.20.20Auto ReportTick Interval30 0 ~0xFF  The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13.Caution: Setting to 0 means turn off all auto report function.21Temperature Differential Report10 ~0x7F  The temperature differential to report.0 means turn off this function. The unit is Fahrenheit.Enable this function the device will detect every minutes.And when the temperature is over 140degree Fahrenheit, it will continue report.Enable this functionality will cause some issue please see the detail in the“Temperature Report” section.11
NO. Name Def. Valid A B DescriptionNO. Name Def. Valid A B Description22IlluminationDifferential Report00 ~0x63  The illumination differential to report.0 means turn off this function.The unit is percentage.Enable this function the device will detect every minutes.Enable this functionality will cause some issue please see the detail in the“Illumination Report” section.NO. Name Def. Valid A B DescriptionNote: Refer A as DCH-Z110, B as DCH-Z120Z-Wave Supported Command ClassCOMMAND_CLASS_ZWAVEPLUS_INFO_V2COMMAND_CLASS_BATTERYCOMMAND_CLASS_NOTIFICATION_V4COMMAND_CLASS_ASSOCIATION_V2COMMAND_CLASS_CONFIGURATIONCOMMAND_CLASS_MANUFACTURER_SPECIFIC_V2COMMAND_CLASS_VERSION_V2COMMAND_CLASS_SENSOR_BINARY_V2COMMAND_CLASS_SENSOR_MULTILEVEL_V5COMMAND_CLASS_WAKE_UP_V2COMMAND_CLASS_ASSOCIATION_GRP_INFOCOMMAND_CLASS_POWERLEVELCOMMAND_CLASS_DEVICE_RESET_LOCALLYCOMMAND_CLASS_MULTI_CMDCOMMAND_CLASS_SECURITYCOMMAND_CLASS_FIRMWARE_UPDATE_MD_V2COMMAND_CLASS_MARKCOMMAND_CLASS_BASICSpecificationsPower by CR123A lithium battery.Signal (Frequency):868.40 MHz, 869.85 MHz(EU),908.42 - 916.00 MHz(US),922~927 MHz(JP/TW),921.40 MHz, 919.80 MHz(ANZ),869.00 MHz(RU),  865.20 MHz(IN),916.00 MHz(IL),Range:Minimum 30 meters indoor, 70 meters outdoor line of sight.Operating Temperature: -10oC ~ 40oCFor indoor use only.Specifications subject to change without notice due to continuing product improvement.   FCC ID for DCH-Z110: KA2CHZ110A1 FCC ID for DCH-z120: KA2CHZ120A112
FCC Interference StatementThis equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. Theselimits are designed  to  provide  reasonable protection  against  harmfulinterference in a residential installation. This equipment generates, usesand can radiate radio frequency energy and, if not installed and used inaccordance with the instructions,   may cause harmful interference toradio   communications.         However,     there   is   no   guarantee   thatinterference will not occur in a particular installation.  If this equipmentdoes cause harmful interference to radio or television reception,  whichcan be determined by turning the equipment off and on,  the user isencouraged to try to correct the interference by one of the followingmeasures:•Reorient or relocate the receiving antenna.•Increase the separation between the equipment and receiver.•Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected.•Consult the dealer or an experienced radio/TV technician for help.This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions:(1) This device may not cause harmful interference, and(2)   This   device   must   accept   any   interference   received,   includinginterference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved bythe party responsible for compliance could void the user's authority tooperate this equipment. This  transmitter  must  not  be  co-located or  operating  in  conjunctionwith any other antenna or transmitter.WarningDo not dispose of electrical appliances as unsorted municipal waste,use   separate   collection   facilities.   Contact   your   local   government   forinformation   regarding   the   collection   systems   available.   If   electricalappliances are disposed of in landfills or dumps, hazardous substancescan leak into the groundwater and get into the food chain, damagingyour health and well-being.When replacing old  appliances  with  new  once, the retailer is legallyobligated to take back your old appliance for disposal at least for freeof charge.13