Creative Industry PC-68A Oximeter User Manual

Shenzhen Creative Industry Co., Ltd. Oximeter

User Manual

Pulse Oximeter Directions for Use  Intended Use This  oximeter  is  intended  to  be  used with  Baby  Monitor,  and  it  is  an additional  or  optional  accessory  to measure  the  functional  arterial  oxygen saturation  (SpO2)  and  pulse  rate  (PR) for  infant  or  baby  in  the  way  of non-invasive and long term monitoring. Contraindications This  oximeter  including  its  sensor  is contraindicated for use on the baby with excessive  movement  or  for  prolonged use at the same measuring site. Instructions for Connection   1) Insert the sensor tips into the  slots on the probe holders. Place the sensor tip labeled “LED” into the stationary probe holder on the silicone wrap belt, and place the sensor tip labeled “PD” into the sliding probe holder, as illustrated in Figure 1 and Figure 2.   Figure 1 Probe tip and holder   Figure 2 Y-type SpO2 Sensor with Rubber Wrap NOTE:  Make  sure  that  the  silicone  button seat fully into the hole in the back of the probe holder.   2) Bind the oximeter on the leg near ankle with its  belts  and  position  the  front  panel  to  a proper  place  for  convenient  operation,  as shown in Figure 4. 3) Wrap up the Y-type sensor onto the baby’s sole by the rubber wrapper, as illustrated in Figure 3. Make sure the alignment of the light-emitting  tip  (LED)  and  the  photo- detecting tip (PD) for aiming at each other, then thread the end of wrap belt through the outside slots on the probe holders and tighten the rubber belt with proper force. The final placement is shown in Figure 4.  Figure 3 Sensor wrapping up   Figure 4 Placement of the Oximeter and the Sensor NOTE: The sensor connection is critical for the  signal  strength  and  quality.  Try  to  make LED and PD facing each other in opposite side, so  that  the  light  beam  is  as  vertically transmitted as possible and the light path is as short as possible. Pulse Oximeter   Y-type SpO2 Sensor with Rubber Wrapper
Shenzhen Creative Industry Co.,Ltd.                            Tel:+86-755-2643 3514   2/F,Block 3,Nanyou Tian’an Industry Town,                Fax: Tel:+86-755-2643 2832 Shenzhen, GD 518054, P.R. China                                 E-mail:market@creative-sz.com Sep.  5,  2014      V1.0 Instructions for Operation After all connection completed, press the Power Button  ( )  for  3  seconds  to  power  on  the oximeter,  referring  to  Figure  5.  When  the oximeter  is  powered  up,  the  Power  Indicator (yellow lamp  ) will light constantly. If the heart beat  is  detected,  the  Heartbeat  Indicator  (red lamp ) flashes according with the heart rate. At the same time the oximeter sends the measured data (SpO2 and PR) to Baby Monitor in a given time interval via wireless communication, and the SpO2 and PR value will be displayed on the terminal side of Baby Monitor.  Figure 5 Appearance of the Pulse Oximeter NOTE: ①The oximeter has not automatic power-off function. Press the Power Button for 3 seconds to turn it off after the end of use each time.②If the Power Indicator flashes, that means the battery voltage is low for the oximeter, please replace the batteries.  Cleaning and Disinfection It  is  recommended  to  clean  the  oximeter including its sensor with 75% Alcohol wipes or 70% Ispropanol (Isopropyl) before use. Caution:①Do  not  sterilize  by  irradiation,   steam,  or  ethylene  oxide.  ②Make  sure  the sensor is dry and clean before use. Warranty Our  company  offers  a  12-month  warranty against manufacturing defects for this product in its undamaged condition. FCC Caution.  § 15.19 Labelling requirements. This device complies with part 15 of the FCC Rules.  Operation  is  subject  to  the  following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept  any  interference  received,  including interference  that  may  cause  undesired operation.  § 15.21 Information to user. Any  Changes  or  modifications  not  expressly approved  by  the  party  responsible  for compliance could  void  the  user's  authority  to operate the equipment.  § 15.105 Information to the user. Note:  This  equipment  has  been  tested  and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful interference  in  a  residential  installation.  This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Pulse Oximeter Directions for Use  However,  there  is  no  guarantee  that interference  will  not  occur  in  a  particular installation.  If  this  equipment  does  cause harmful  interference  to  radio  or  television reception, which can be determined by turning the  equipment  off  and  on,  the  user  is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase  the  separation  between  the equipment and receiver. -Connect  the  equipment  into  an  outlet  on  a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.  * RF warning for Portable device: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Navigation menu