Corning Optical Communication MA2000 In-Building RF Distribution Sytem User Manual MobileAccess 2000

Corning Optical Communication Wireless In-Building RF Distribution Sytem MobileAccess 2000

User Manual 2 of 2

  Rack and Cabinet Installations  3.4  MA 850 Installations MA 850 may be integrated into the MA 2000 system using one of the following installations: Installing it directly on the MA 2000 RC top panel (using the supplied plate); • • • Mounting it on a rack (using the supplied plate); Wall mount near the MA 2000 cabinet.  The coax outputs of the cabinet are connected to the appropriate ports on the MA 850 and the antennas are connected directly to the MA 850 module.  3.4.1  MA 850 RC 2000 Assembly 1.  Assemble two side brackets to the plate sides as illustrated in Figure 3-10. 2.  Assemble the MA 850 module to the supplied bracket using the four screws and washers as illustrated below.  Side bracket assembly Connections toantennas Side bracket assembly Connections to RemoteCabinet antenna portsFigure 3-10. MA 850 Rack Installation   Installation and Configuration Guide  21
Rack and Cabinet Installations 3.  Assemble the plate to the MA 2000 RC by securing the brackets to the cabinet sides as illustrated below.  Connection toRemote  Cabinetantenna portsPlate assembly secured to RC with side brackets Figure 3-11. Illustration of MA 850 Mounted on MA 2000 RC 4.  Connect the RC antenna ports to the MA 850 front panel port connectors as illustrated below.  Connections toantennasFigure 3-12. Illustration of RC Antenna port connections 5.  Connect the antennas to the MA 850 antenna ports.22  Installation and Configuration Guide
  Rack and Cabinet Installations   3.4.2  MA 850 Rack Mount 1.  Assemble the side brackets as illustrated in Figure 3-10. 2.  Assemble the MA 850 module to the supplied bracket using the four screws and washers. 3.  Mount the assembly in the rack using the side brackets.  Connections toantennasConnections toRC antenna portsFigure 3-13. MA 850 to Bracket Installation 4.  Connect the RC antenna ports to the SMA connectors on the MA 850 front panel. 5.  Connect the antenna to the MA 850 antenna ports. 3.4.3  MA 850 Wall Mount Installation The MA 850 may be mounted independently on the wall near the RC cabinet. 1.  Connect the RC antenna ports to the SMA connectors on the MA 850 front panel. 2.  Connect the antenna to the MA 850 antenna ports.   Installation and Configuration Guide  23
Rack and Cabinet Installations  3.5  2000 Lite Installation and Connections MA 2000 Lite is designed to be a wall mounted device. It is usually installed in the communication shaft of the corresponding floor and is powered from an external power source. It may also be connected to a backup battery. The remote units are mounted externally to the 2000 Lite device and their antenna outputs are connected to either side of the 2000 Lite device. The combined outputs are then connected to the antennas in the covered area. 2000 Lite is capable of supporting two types of remote units: RU 2000 and  MA 850 (wireless 802.11a/b/g coverage). A MA 1200 add-on module can be connected to each RU 2000 module to provide additional services. The MA 2000 Lite connections are shown in the following figures. Note that the power connections are on the underside, and the coax connections are at the sides of the modules.   Connections to RU antenna ports or MA 850 SMA ports (if a MA 850 module is installed)to Connections to Antennas Connections to RU antenna ports or to MA 850 SMA ports (if a MA 850 module is installed) Figure 3-14. 2000 Lite System coax connections  3.5.1  MA 2000 Lite Coax Connections 1.  Connect the RU 2000 antenna ports to the appropriate connectors at the side of the MA 2000 Lite module. NOTE: The additional require RU 2000 connections are described in section 4.4 1.  .2.  Connect the antennas to the MA 2000 Lite antenna ports. 3.5.2  MA 850 Installation Connections 1. Connect the 2000 Lite antenna ports to the MA 850 From Mobile Services connectors on the MA 850 front panel. 2. Connect the antennas to the MA 850 Antenna ports. 24  Installation and Configuration Guide
 System Elements  44  SSyysstteemm  EElleemmeennttss         4.1 Overview This chapter describes each of the system elements, and their individual connections. It can be used as reference to verify the connections of each module or to upgrade your system. In order to describe the installation process clearly, it will be described as consisting of two logical parts:  A.  Telecommunications room – installing the RIUs,  BUs,  MA 410/430 controllers, and the required passive equipment in the telecommunication room close to the RF signal source. This installation may differ between single  and multi-building topologies. B.  Remote locations –  RC installations and connections. These are usually wall mounts.  The installations for two basic topologies are described in detail: for single building and for multi-building. By understanding the two generic installations you will be able to address any variations in system deployment. NOTE: For installations that include the MA NMS: Once the installation has been completed  it can be verified using the MCT application (NMS User’s Guide) and the devices monitored using the NMS Manager (NMS User’s Guide). ,  Installation and Configuration Guide  25
System Elements  4.2  MA 2000 Remote Cabinet The MA 2000 Remote Cabinet can house various combinations of up to five RU 2000 and MA 1200 add-on modules. The number of modules depends on the models, required filtering, etc. In addition, a MA 850 module may be installed externally. The Remote Cabinet provides the filtering, combining, power interface and antenna interface functions. NOTE: If an MA 860 module is installed as well, the antenna outputs are further connected  to the appropriate connec ions on the MA 850 and the antennas then connec ed to the MA 850 antenna connections. t tThe optic connection from the BUs are routed internally and connected directly to the corresponding RU 2000 module. The MA 2000 Remote Cabinet is provided in two power configurations:  •  Integrated power supply – a power supply is integrated into the cabinet and fed from an external AC power source. The individual modules are internally connected to the power supply. This model includes a battery connection as well. •  External power supplies – the power source is external to the cabinet: it can be from a central remote source (most common configuration) or from local installed dedicated power supplies.  Power is routed to external connectors on the Remote Cabinet, where each external power connector is internally connected to a specific module. The cabinet may be mounted on a wall or in a 19” rack. The appropriate brackets are provided with each type of installation. The MA 2000 remote cabinet is illustrated below:  Antenna sensing monitoring connection (future option) 4x coax cable  antenna ports Figure 4-1. RC 2000 Closed Cabinet View  26  Installation and Configuration Guide
 System Elements  The following figure shows an open RC 2000 cabinet, integrated power supply model, with four RU 2000 modules and four filters. (For clarity, the internal connections are not included).  Slot for fittingOptic Fibers Optic fiber connection from the corresponding BU Internal DC module connections  Splitter/Combiner connections Filters (four in this configuration example) AC power input to integrated power supplyAntenna portsConnection to external battery  Figure 4-2. RC 2000 Open Cabinet View (without internal connections) The following image shows the MA 2000 RC with the cabling. Note that the antenna ports of the individual modules are connected to the internal RF connections (under the antenna ports) and the filters as required. The PS connections of each module are also connected to cables that are internally routed to the integrated PS.  NOTE: The fiber optic connections are not displayed.  Figure 4-3. RC Open Cabinet with Internal Cabling     Installation and Configuration Guide  27
System Elements 4.3  MA 2000 2000 Lite Installation The 2000 Lite provides the required interface and filtering required to support two RU 2000 modules to which MA 1200 add-on modules can be connected for additional services. This MA 2000 configuration is fed from external power supplies. The RU 2000 modules, the dedicated power supplies and any MA 1200 add-on modules are installed externally to the 2000 Lite.    Connections to RU antenna ports or MA 850 SMA ports (if a MA 850module is installed)to Connections to Antennas Connections to RU antenna ports or to MA 850 SMA ports (if a MA 850 module is installed) Figure 4-4. 2000 Lite System coax connections   4.3.1 Connections 1.  Connect the power connections to the 2000 Lite, the MA 2000 RUs and any other connected MA 1200 add-on modules. 2.  Connect the antenna ports of each RU 2000 module to the appropriate connector on the 2000 Lite. 3.  Connect the remote module optic fiber connections.   4.  Connect the antenna coax infrastructure cables to the 2000 Lite connectors. 4.4  Remote Modules  The Optical to RF conversion of each service at the individual building floors is performed by Remote Units (RU) 2000 modules corresponding to the service types. These consist of MA 2000 RUs and in addition, may include MA 1200 and MA 850 modules.  The location installations may be performed in various configurations depending on the requirements of the site and the supported services. If a Remote Cabinet installation is performed, the RU 2000 and MA 1200 modules are housed inside the cabinet while the MA 850 module is installed externally and integrated into the system. If a 2000 Lite installation is performed, the modules are installed externally to the enclosure. 28  Installation and Configuration Guide
 System Elements  The following sections describe each of the elements and the connections as they relate to the MA 2000 system. 4.4.1 Remote Units 2000 Each RU supports two different services (one high-band and one low-band).  All RUs are add-on ready, meaning that an additional (high-power) service can be added by connecting a 1200 add-on module to the RU.  A fiber optic connection is implemented between each RU 2000 and corresponding BU. The RU may be remotely monitored through the corresponding BU connection to the MA NMS.   The RU 2000 services, MA 1200 add-on service and MA 850 data services at each location are combined prior to transmission to strategically placed antennas.   RU 2000 Front Panel The RU 2000 front panel contains the fiber optic connections to the BU, four coax connections to the antennas, power connections and status indicators.   MA service connectorLEDsFiber optic connections To– and From- the BU Four Antenna port  Power connectorFigure 4-5. RU 2000 Front Panel Table 4-1. RU 2000 Front Panel Indicators LED  Description COMM  Active communication detected LINK  Optical link to BU detected PWR  DC power connected    Installation and Configuration Guide  29
System Elements RU 2000 Rear Panel The RU 2000 rear-panel provides the control, RF interface and optic interface ports that enable connecting an MA 1200 add-on unit to the RU 2000 module.  In addition, the RU rear panel contains the Infrared (IR) sensor used for internal information exchange between the RU 2000 modules and the cabinet in which they are installed (Remote Cabinet configuration only).   Figure 4-6. RU 2000 Rear Table 4-2. RU 2000 Rear Panel Connectors Add-on control  Transmits the control signals from MA 1200 add-on module to the  RU 2000 module. The Add-on Control port is connected to the MA 1200 add-on From port.  DL, UL  Transmit the RF signals to- and from- the MA 1200 add-on module. These ports are connected to the corresponding ports on the MA 1200 rear panel: DL to DL, UL to UL.  Connections 1.  Install splice box near Remote Cabinet. 2.  Connect fiber optic cable to splice box and the SC/APC pigtails to the RU 2000.  3. For the downlink, connect the fiber optic cable pigtails from splice box coming from the BU port to the corresponding RU port.  4. For the uplink, connect the fiber optic cable pigtails from splice box from the RU to the uplink port that connects to the BU.  5. Connect the power according to power design planning: external (central or dedicated) or integrated power supply (internal connections).   ATTENTION: Verify that 50 ohm terminators are placed on the unused uplink and downlink connectors. 30  Installation and Configuration Guide
 System Elements    4.4.2  MA 1200 Add-on The MobileAccess 1200 Add-on module is a high power module, supporting a single frequency band (low or high). It is designed to be integrated with a RU 2000 module. The RHU 1200 add-on is housed in the MA 2000 cabinet and connected to a RU 2000 that provides the interface to the optical, RF and control signals for both modules.  RHU 1200 Front Panel The RHU 1200 front panel contains the power connection and status LEDs (the RS-232 connector is reserved for MA service personnel).    Service connector Figure 4-7. RHU 1200 Front panels Table 4-3. MobileAccess 1200 Front Panel Indicators LED  Description RUN  When blinking, indicates that the RHU is in normal operating mode. PWR Power ON    Installation and Configuration Guide  31
System Elements  RHU 1200 Rear Panel The RHU 1200 rear panel contains the control connectors and the RF connections to the RU 2000 and MA 850.   ULDLHigh BandFigure 4-8. RHU 1200 Rear Panel Table 4-4. RU 1200 Rear Panel Connectors Add-on Control   Transmits the control signals between the MA 1200 module and the MA 850 and RU 2000 modules.  From – receives control signals from the RU 2000. Connected to the RU 2000 Add-on Control connector. DL, UL  Transmit the RF signals to- and from- the MA 1200 add-on module. These ports are connected to the corresponding ports on the MA 2000 rear panel: DL to DL, UL to UL. High  Service RF output port.  Connected to combiner/splitter to be combined with other services supported by the MA 2000 system.   Connections 1.  Connect the power to the DC connector on the front panel. 2. Connect the MA 1200 From connector to the Add-on Control connector of the corresponding MA 2000 RU. 3. Connect the High Band port to the Combiner connectors.  4. Connect the DL, UL connectors to the corresponding connectors on the MA 2000 module. 32  Installation and Configuration Guide
 System Elements   4.4.3 MA-850 Module MobileAccess 850 provides a secure and centralized connection for 802.11a/b/g Access Points. It significantly expands 802.11 coverage and enables distributing data and voice services over the same coax and antenna infrastructure used by MA 2000 system.  MA 850 may be assembled on the MA 2000 cabinet top panel, or adjacent to the MA 2000 system (either Remote Cabinet or 2000 Lite configuration). It is integrated into the MA 2000 system by interconnecting the appropriate connectors. The combined signals of the MA 2000 system input to the MA 850 module and then distributed through the same coax broadband antenna infrastructure connected to the MA 850. MA 850 may be remotely monitored through the RU 2000 system to which it is integrated, and remotely configured through a point-to-point Ethernet connection. The MA 850 front and rear panels, connectors and connections are described in detail in the following sections. MA 850 Front Panel The MA 850 front panel contains the antenna ports interfaces, local configuration interface and power connection. The following figure shows the MA 850 front panel.  Connections to corresponding antenna ports of remote unitAntenna ports PowerLocal RS232 connection  for configuration   Figure 4-9. MobileAccess 850 Front View Table 4-5. MA 850 Front Panel Connections Front Panel  Description Mobile Services  Four SMA female connections to which the antenna port of the MA 2000 system are connected.    To be terminated with 50 ohm terminations when not in use Antenna Ports  Four n-type female antenna connections Local  Local connection for setup DC  Power connection: 20V to 48V from a standard power supply    Installation and Configuration Guide  33
System Elements  MA 850 Rear Panel The MA 850 rear panel contains the connections to the APs, the Ethernet port for remote configuration and the connection to the MA 1200 add-on control (if an MA 1200 add-on unit is installed)  Ethernet Port Connection toadd-on control802.11 a APs connections 802.11 b/g APs connections   Figure 4-10. MobileAccess 850 Rear View Table 4-6. MA 850 Reart Panel Connections Rear Panel  Description 802.11b,g APs  Connection to up to four 802.11b/g APs, where associated LED Lite under the following conditions: •  Green: indicates where AP should be connected after configuration •  Green flickering: Link with AP established but no data is received •  Red: AP transmitting data 802.11a APs  Connection to up to four 802.11a APs Connection to control Connection to MA 1200 To connector on the rear panel. Used for viewing antenna status Ethernet port  Connection to network for Web configuration  4.5  Radio Interface Unit (RIU) The RIU is an operator dedicated unit that interfaces to up to three BTS sources and automatically adjusts the signal output according to changing environmental conditions in order to provide optimal coverage for the site. The RIU is remotely monitored and managed. Each RIU can support up to three BTS Conditioner (BTSC) sub-modules, where each sub-module provides interface to a BTS or BDA of the same type of service.   Each RIU can be connected to four 8-port Base Units (real panel connections) or to eight 4-port Base Units.   Additional BUs can be supported by using splitters and combiners connected to the front panel Expansion connectors.  The following figures shows an RIU with three BTSC sub-modules.   34  Installation and Configuration Guide
 System Elements   Figure 4-11. RIU  Note: All connections are via RG223 coax cables with 1/2" N-type male connectors  ATTENTION 1.  The RIU is factory set to 0dB gain on the uplink and downlink. In order to operate properly, an ADJUSTMENT process is required in the field. 2.  Any unused input and output connectors MUST be terminated with 50 ohms – otherwise the ADJUSMENT procedure results may be affected.   Installation and Configuration Guide  35
System Elements  RIU Front Panel The RIU front panel contains the indicators and expansion connectors for the connection of additional BUs.      Power Supply  BTS Conditioners  Expansion connectors - for connecting additional BUs Figure 4-12.  RIU Front Panel Table 4-7.  RIU Front Panel Indicators LED Description P.S UNIT PWR  ON – input signal is at the required level. BTS CONDITIONER RUN Flashing -- CPU is running and software loaded BTS CONDITIONER DL OVERLOAD Continuous Red – RF switch is disconnected to protect the system. This may be due to:  •  Unpredicted power rise for which the attenuation response was insufficient to compensate and reduce the power to the required level.   •  Software problem detected. Flashing:  When the BTSC DL output power is more than 3dB of the calibrated value. BTS CONDITIONER DL LOW Continuous Red – if the BTSC DL power is at least 15dB lower than the calibrated BTSC max power level.  This condition also triggers an event.  36  Installation and Configuration Guide
 System Elements   RIU Rear Panel The rear-panel provides all the connections on the BTS side and on the BU side as well as connections to the MobileAccess 410/430 controller and the power connection. Two types of BTS side connections are available for each BTS conditioner: simplex and duplex.   BTS/BDA simplex  connections   BU connections; one UL and one DLconnection for every group of four ports(single OPTM) on the BU.  BTS/BDA duplex connections  Power connectionMA Controller connectionFigure 4-13. RIU Rear Panel showing the RF Connection RIU Connections 1. Connect each BU to the corresponding RF Uplink and Downlink connectors on the RIU rear panel.  Note that one uplink and one downlink  RIU rear-panel ports are used to connect one OPTM (four ports from the BU); two uplink and two downlink ports are used to connect an 8-port BU (two OPTMs).       MobileAccess 1000 BU connections (pair per BU)  BTS/BDA duplex connectionsBTS/BDA simplexconnectionsController connectionPower connectionFigure 4-14. RIU Rear Panel showing the RF Connection   Installation and Configuration Guide  37
System Elements NOTE:  Up to four 8-port BU may be connected. Additional BUs may be connected through the Extension connector on the front panel. Refer to section Connections to Additional BUs, page 38. 2.  Connect each BTS/BDA to the corresponding rear panel BTSC connectors. For each BTSC connection, both simplex and duplex connections are available: For a duplex connection, connect to the BTSC DUP port; • •  For a simplex connection, connect to the BTSC UL and DL ports;  3. Connect the Power connections on the RIU rear panel. 4.  If your system includes a MA 410/430 controller, connect the RS485 port on the RIU rear panel to the controller.   Connections to Additional BUs  To connect more than four 8-port BUs or more than eight 4-port BUs to the RIU, Connect an 8W splitter to the Downlink connector on the RIU front panel and an 8W combiner to the Uplink  connector on the RIU front panel and connect additional BUs to the uplink and downlink connections.  Expansion portsBTSCBTSCBTSCBTSCBTSCBTSCCombiners /Splitters Compartment*UL and DL connections to four BU8 modulesUL and DL connections to up to four additional BU8 modulesExternal 1:8 splitter /combiner 4.6  MA Base Units  The BUs (Base Units) perform RF to optical conversion of the signal on the BTS/BDA side. Each can support up to two services (provided by the same operator). Two models of MA BUs are available: four-port unit – supporting four RUs, and eight-port unit supporting up to eight RUs.  The RU models correspond to the services supplied through the BUs.   The BU (and all the corresponding remote units) may be remotely monitored and managed via the MA NMS (Network Management System).  The BUs are usually installed in the telecom room adjacent to the BTS/BDA signal source. RF ports on the rear panel provide interface to the BTS side (through connection to RIU or passive interface), while optic ports on the front panel provide interface to the RUs (Remote Units).  This following sections describe the MA BU front and rear panels, including indicators and connectors. 38  Installation and Configuration Guide
 System Elements  MA BU Front Panel The front panel contains the optical connections and indicators. The BU is available in two configurations: Four-port - and Eight-port BUs. The eight-port BU consists of two four-port elements where each four-port element has a dedicated set of indicators (PWR, LSR and Link 1 to Link 4 or Link 5 to Link 8).  Four ports and corresponding indicators Four ports and corresponding indicatorsFigure 4-15. Eight-Port MA BU Front Panel   Figure 4-16. Four-Port BU Front Panel Table 4-8. MA BU Front Panel Indicators LED  Description PWR  Power input detected for the corresponding unit. LSR  ON - laser circuitry for the corresponding element (group of four ports) is functioning correctly. Link 1-4, 5-8  ON - the optical link to/from the connected remote functions within the specifications in both directions.  Blinking - optical power from remote is lower than expected by at least 2dBm     Installation and Configuration Guide  39
System Elements BU Rear Panel The BU rear panel contains the RF, Alarms, NMS and power connections. Note that there are two uplink and two downlink RF connections to the BTS side (to an Interface Box or RIU) - each individual uplink and downlink connection corresponds to a four-port BU element. For a four-port BU, one uplink and one downlink port is connected; for an eight-port BU, two uplink and two downlink ports are connected.  For systems that include MA 430 controllers, the RS 485 port is connected to the MA 410/430 controller to enable remote monitoring and management of the BU from a central location. For systems without remote management, the Alarms dry-contact connector pins can be connected to the BTS to provide alarms functionality.   Pair of uplink and downlink RF  connections for interface to BTS side.  MA 410/430 controllerAlarms dry-contact connector   Power Figure 4-17. MA BU Rear Panel (RF Connections) Table 4-9. MobileAccess 1000 Rear Panel Connections Connector  Description Uplink output  Uplink connectors to be connected on BTS side. Downlink input  Downlink connectors to be connected on the BTS side.  Com Port RS485  Connection to MobileAccess 410/430 controller.  PWR   Power connection Alarms Dry-contact connections to BTS/BDA (normally closed). Relevant only for system without MA 410/430 controllers.   BU connections 1.  It is assumed that the patch panel cabinet (SC/APC adaptors) for fiber optic cable connections is installed in the rack near the BUs.  2.  Connect (3/125/900) pigtail with SC/APC connectors between splice tray and patch panel cabinet.  3.  Connect (3/125/3000) SC/APC jumpers between the corresponding BU and patch panel.  4.  Connect the fiber optic cables from the BU to the RUs through the patch panel cabinet.  5.  Connect the UL RF Output and DL RF Input connectors to the RIU or UL and DL connectors or to the passive interface (such as Interface Box) in topologies that do not include RIUs.40  Installation and Configuration Guide
 System Elements   4.7  MobileAccess NMS System NOTE  This section provides general information on the MobileAccess 410/430 Controller.  :For detailed information on the controller, configuration and connections refer to the Mobile Access NMS User’s Guide.  The MobileAccess controllers enable managing and controlling the MobileAccess system elements.  All the monitoring and control operations can be performed from the Master’s location.  Two MobileAccess controller configurations are provided: MobileAccess 410 and MobileAccess 430.  The models differ in their remote access capabilities: •  MobileAccess 410 provides point-to-point connectivity implemented via either direct RS232 connection or via connection to a DSPN phone line •  MobileAccess 430 provides client/server management capability over TCP/IP network with enhanced monitoring and control capabilities (in addition to the connectivity options provided by MobileAccess 410).   NOTE  The MobileAccess 430 front panel is differentiated from the MobileAccess 410 front :panel by the SNMP Agent Card that provides TCP IP management capabilities.  /  Controller Front Panel    Major, Minor LED indicators   Local RS232 connection (for IP address setup) Master/Slave configuration LCD alarm display corresponding to Major and Minor LEDs  Run and  Power LEDs Figure 4-18. MobileAccess 410 Front Panel  TCP/IP connection Local RS232 connection to Laptop  (MA 300  for Remote controller)  Figure 4-19. MobileAccess 430 Front Panel   Installation and Configuration Guide  41
System Elements  Controller Rear Panel Note:  The rear panels for the MobileAccess 410 and MobileAccess 430 are the same.   MA BU and RIU inputs  Slave controller connections BTS alarms output   DC Input  General purpose alarms input (MA 300).  Figure 4-20. MobileAccess 410/430 Rear Panel          42  Installation and Configuration Guide
55  AAppppeennddiixx  II::  OOppttiiccaall  TTeesstt  PPrroocceedduurreess  5.1 General Two parameters are of prime importance when testing optical cables or jumpers for use with Mobile Access products: •  Optical Loss – the difference between the optical power at the input and output of an optical cable. It must be measured (usually in dB units) at 1310 nm. The maximum allowable loss should be < 0.5 dB/km for Single Mode (SM) cables and < 0.5 dB for every mated pair of connectors. •  Optical Backreflection – the percentage of light backreflected from the fiber input (dB units). The maximum allowable backreflection should be < –55 dB for all jumper cables.   The methods to test these parameters will be described below.   5.2  Optical Loss Testing of a Single Mode Cable with SC/APC connectors at each end  5.2.1  Required Test Equipment •  1310 nm Stabilized Laser Source •  1310 nm Optical Power Meter •  Two Fiber Optic Test Jumpers with SC/APC connectors at each end •  Two SC/APC Adapters    Installation and Configuration Guide  43
Appendix I: Optical Test Procedures 5.2.2 Test Procedure 1.  Set up the Laser Source, Optical Power Meter, and Test Jumper as shown below.   Figure 5-1. Set Up 2.  Record reading as P1 in dBm units.  3.  Serially connect the second Test Jumper as shown below.  Figure 5-2. Serial Connection of Second Jumper 4.  Record the Power Meter Reading as P2 in dBm units.  5. Calculate Loss L12 according to the equation: L12 = P1 - P2  6.  If L12 is lower than 0.5 dB continue to Step-7; otherwise replace these test cables and repeat from Step-1. 44  Installation and Configuration Guide
  Appendix I: Optical Test Procedures  7. Disconnect connectors B and C. Connect the Cable Under Test (CUT) between connector B and C as shown below.   Figure 5-3. Connecting CUT 8.  Record Power Meter reading as Pcut in dBm units.  9.  Calculate Cable Loss Ldut from the equation Lcut = P2- Pcut.  10. The maximum allowable loss should be < 0.5 dB/km for SM cables and < 0.5 dB for every mated pair of connectors. 5.2.3 Example Testing a 50 meter cable with SC/APC connectors at each end. •  P1 = -1dBm •  P2 = -1.5dBm •  L12= P1 – P2 = -1dBm - (-1.5) = 0.5 dB Conclusion: the test cables are of sufficient quality to continue testing. •  Pcut = -2dBm •  Lcut = P2 - Pcut= -1.5dBm - (-2dBm) = 0.5 dB  This is acceptable since a mated connector pair was added along with the CUT and a loss of   -0.5 dB is allowed for every mated pair of connectors.     Installation and Configuration Guide  45
Appendix I: Optical Test Procedures      5.3  Optical Backreflection Testing of SM SC/APC connectors at each end of an optical cable 5.3.1  Required Test Equipment 1.  Adjustable1310 nm Stabilized Laser Source with output power greater than 7dBm.  2.  1310 nm Optical Power Meter with a measurement range of up to -70 dBm. 3.  One low loss Singlemode 1310 nm 2x2 50%/50% Fiber Optic Coupler with SC/APC connectors at all four fiber pigtailed ports. Pigtail length should be 50 cm.  4. One SC/APC Adapter 5.3.2 Test Procedure 1.  Refer to the following figure for port definitions of the Fiber Optic Coupler. The coupler is symmetrical but for our purposes, each port should be identified as shown in Figure 1-4.  Figure 5-4. Port Identification 2.  Measure the loss from port I1 to O1 according to the insertion loss method described in the previous section. This loss will be referred to as LI1O1. It should be approximately 3.5 dB.  3.  Measure the loss from port O1 to I2 in a similar manner.  This loss will be referred to as LO1I2. It should also be approximately 3.5 dB.  4. Calculate Total Loss, TL where TL= LI1O1 + LO1I2. TL should approximately 7dB. 5.  Adjust the laser output power in dBm to the same value as TL.  For example, if TL = 7dB, adjust the laser output to 7 dBm. 46  Installation and Configuration Guide
  Appendix I: Optical Test Procedures    Installation and Configuration Guide  47 6.  Connect the laser to port I1 of the coupler as shown in Figure 5-5.  Figure 5-5. Test Procedure Connections 7.  Connect the Power Meter to port I2 of the coupler as shown in Figure 5-5.  8. Wrap the O2 pigtail around a pencil of diameter 7 to 8 mm as illustrated.  9.  The power meter readings should be < –58 dBm; otherwise, clean connector O1 and measure again. 10. Connect the cable under test to connector O1.  11. Record Power Meter Reading as Backreflection, BRcut, of the cable under test. The power is measured in dBm units. This is the same value as the backreflection.  For example, if the power meter shows –58 dBm, the backreflection is –58 dB. The maximum backreflection from the SC/APC connectors should be  < –57 dB.  Long cables will have a higher BR since the cable itself reflects a small amount of light. This small amount can grow to a considerable amount over a long length of fiber. To factor out this cable backreflection, perform a mandrel wrap on the cable adjacent to the connector under test and perform all measurements with the mandrel wrap.

Navigation menu