Convergence Systems CS506 RFID ACTIVE TAG User Manual CSL RTLS 2 0 2

Convergence Systems Limited RFID ACTIVE TAG CSL RTLS 2 0 2

Users Manual

  1    User Manual of CSL RTLS System   CS506 Tag CS5111TD Reader CS5112TD Reader CS5113TD Reader with Ethernet Bridge CS5114TD Reader with Ethernet Bridge CS5116TD Reader   CS5118TD Reader with Ethernet Bridge
  2 FCC Statement    FCC NOTICE: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility  of  the  operator  and  professional  installer  to  ensure  that  only  certified systems  are  deployed  in  the  United  States.  The  use  of  the  system  in  any  other combination is expressly forbidden.
  3 Table of Content  User Manual of CSL RTLS System...............................................................................1 Introduction..................................................................................................................4 1 System Component Description..........................................................................5 1.1  CS506.........................................................................................................5 1.1.1  Product Description .......................................................................5 1.1.2  Installation Procedure ....................................................................6 1.1.3  Product Specification.....................................................................7 1.2  CS5111TD/CS5112TD ..............................................................................8 1.2.1  Product Description .......................................................................8 1.2.2  Installation Procedure ....................................................................9 1.2.3  Product Specifications .................................................................11 1.3  CS5113TD/CS5114TD ............................................................................12 1.3.1  Product Description .....................................................................12 1.3.2  Installation procedure...................................................................14 1.3.3  Product Specifications .................................................................15
  4 Introduction The CSL RTLS solution is based on the application of time of arrival technology. In the RTLS, an anchor is the device installed in a known position inside a zone, normally, at the corners of the zone. The moving tag inside the zone can measure the range to each anchor so as to obtain its absolute position inside the zone. A ZoneAnchor AnchorAnchorAnchorTag In  a  minimum  system,  4  anchors  –  3  slave  anchors  CS5111TD/CS5112TD  and  1 master anchor CS5113TD/CS5114TD- are installed in a zone. However, the more the anchors are installed, the higher the accuracy of the tag position to be obtained.   The accuracy of positioning is +/-1 meter.
  5  1 System Component Description  1.1 CS506 1.1.1 Product Description CS506  is  an  active  RFID  tag  operating  in  the  2.4GHz  band.  The  power  is provided via the SDIO interface of platform( such as a PDA).
  6   1.1.2 Installation Procedure
  7 When  the  CS506  is  plugged  into  the  platform,  it  will  start  to  operate automatically. In the first few seconds, it is in the registration mode. Once it is registered to a CS5113LP master anchor, it will be drawn into operating mode immediately and ready for RTLS tracking.  1.1.3 Product Specification  Specifications:  Physical Characteristics: Plastic  sealed  enclosure:  57  mm  x  57  mm  x  18  mm; Weight 35 g for the CS506 standalone   Read Range: Up to 100 meters depending on reader power Frequency: 2400-2483 MHz ISM license-free band Environment: Operating Temp:    -40°°°°C to 65°°°°C (-40°°°°F to 149°°°°F) Storage Temp:            -40°°°°C to 85°°°°C (-40°°°°F to 185°°°°F) Humidity:                    0% to 95% RH non-condensing Technology: CHIRP Output RF Power: 0 dBm EIRP Ranging Method: Time Of Arrival (TOA) Ranging Accuracy: +/- 1 meter Protocol: CSL RTLS Protocol, orderly inventory method to handle large tag population Power: +3.3V 180mA via SDIO interface Order Code: CS506
  8     1.2 CS5111TD/CS5112TD 1.2.1 Product Description CS5111TD/CS5112TD  are  the  RTLS  anchor(  or  reader).  The  high  gain 2.4GHz ISM band antenna and the electronics PCB are integrated into one housing  for  robustness  and  easy  installation.  CS5111TD/CS5112TD  are designed to be mounted at the back panel.
  9  1.2.2 Installation Procedure CS5111TD/CS5112TD  can  be  fed  with  DC  voltage  ranges  from  12V  to 24Vdc. The dc plug is 2.5mm locked type. CS5111TD/CS5112TD are fully
  10 programmed  and  ready  for  normal  operation  once  power  is  on.  No  extra configuration procedure is required.
  11  1.2.3 Product Specifications
  12  1.3 CS5113TD/CS5114TD 1.3.1 Product Description CS5113TD/CS5114TD is the RTLS master anchor( or reader). It integrates the high gain 2.4GHz ISM band antenna and the electronics PCB into one housing  for  robustness  and  easy  installation.  CS5113TD/CS5114TD  has Ethernet connectivity function  to communicate with the server application. CS5113TD/CS5114TD  is  also  a  POE  PD  that  can  allow  it  to  be  powered through IEEE 802.3 certified PSE.
  13
  14  1.3.2 Installation procedure CS5113TD/CS5114TD  can  be  fed  with  DC  voltage  ranges  from  12V  to 34Vdc.  The  dc  plug  is  2.5mm  locked  type.  Once  powered  on, CS5113TD/CS5114TD  is  ready  to  communicate  with  server  through Ethernet port for configuration and RTLS functions.  CS5113TD/CS5114TD can also be powered by a IEEE802.3 certified PSE. When the POE is in function, the DC adapter should be unplugged from the DC jack.    When  connected  to  the  server  via  Ethernet  connection,  Shielded-FTP Ethernet cables should be used to for optimal performance.
  15  1.3.3 Product Specifications
  16 Federal Communications Commission Interference Statement  This equipment  has been tested and found  to comply with the limits for a  Class B digital device, pursuant  to  Part 15 of the  FCC  Rules. These limits  are  designed to provide reasonable protection against harmful interference in a residential installation. This  equipment  generates,  uses  and  can  radiate  radio frequency  energy  and,  if  not installed and used in accordance with the instructions, may cause harmful interference to  radio communications.  However,  there is no  guarantee  that interference will  not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and  on,  the  user  is  encouraged  to  try  to  correct  the  interference  by  one  of  the following measures:  _ Reorient or relocate the receiving antenna. _ Increase the separation between the equipment and receiver. _ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. _ Consult the dealer or an experienced radio/TV technician for help.  FCC  Caution:  Any  changes  or  modifications  not  expressly  approved  by  the  party responsible for compliance could void the user's authority to operate this equipment. This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is  subject  to  the following two conditions: (1) This device may not cause harmful interference, and (2) this  device  must  accept  any  interference  received,  including  interference  that  may cause undesired operation.(3) This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.