Concealite Life Safety SS2000 Sensor Control Switch User Manual SpaceStation2000 Installation Final3

Concealite Life Safety Products Sensor Control Switch SpaceStation2000 Installation Final3

Users Manual

þþDo not let power supply cords touch hot surfaces. þDo not mount units where they will be exposed to direct sunlight, radiators, gas or electric heaters.  Prolonged exposure to temperatures exceeding 95 degrees Fahrenheit may reduce battery life and void warranty.þEquipment should be mounted securely in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel.þThe use of accessory equipment not recommended by the MANUFACTURER may cause an unsafe condition.þThe AC voltage rating of this equipment is specified on the product label. Do not connect equipment to any other voltage.þDo not use this equipment for other than its intended purpose.þServicing of this equipment should be performed by qualified service personnel.TECHNICAL DATAModel:Ac Supply Voltage: 120/277 Volts (+/- 10%)Maximum Load: 120v/400w  230v/1000w  277v/1200w  Maximum Ballast LoadOperating Voltage: 50/60hz, 120-277v +/- 10%Switched Power:                   400w/1000w/1200wStandby Power: 0.6w (standby), 1.2w (operation) 10 / 30 / 50 / 75 100%, Can Be CustomizedHold Time: 5s / 30s / 180s /300s /15min / 25min, Can Be CustomizedDaylight Threshold  OPTIONAL: 20FC - 300FC Daylight / Twilight / Darkness, Can Be CustomizedSensor Principle: Microwave Motion DetectorMicrowave Frequency: 5.8 Ghz +/- 75mhzMicrowave Power: <1mwDetection Range: Max. (0 X H): 8m X 10mDetection Angle: 02° 150°Mounting Height: 0.5 - 100mOperating Temperature: -35°c `-  +70°cIP Rating: IP 20 (mounting inside a lamp); IP 65 (mounting in special box)       Do not use outdoors.TM  Installation InstructionsCopyright© Concealite Life Safety Products.  All Rights Reserved. Specifications Subject to Change. Please Save These InstructionsSpaceStation Occupancy Lighting Control System !Important Safeguards  Read and Follow All Safety InstructionsLimited WarrantyAll Concealite fixtures are  tested and are  guaranteed  to  be  free  from defective materials  and  workmanship for a period of three years from date of shipment under normal operations and proper use.   Correction of all defects shall  be  by  replacement  or  repair  (at our  discretion)  and  shall  constitute fulfillment  of  all  manufacturer's obligations.      We  will  not  allow  any charge  for  labor,  materials,  etc.  that does  not  have  our  written  approval before  the  work  is  begun.    Damage incurring in handling or in transit are not covered by this guarantee.   Any other warranty,  expressed  or  implied,  is hereby  void.    Modifications  to  the product or failure to follow installation instructions will void the warranty.  Index1   Important Safeguards2Sensor Mounting3Sensor Adjustments4New Construction/Retrofit5   Single Wiring6   Multiple Wiring7   Adjustable Remote Mounting (ARM)8   TroubleshootingPhone:  605.542.4444     concealite.comSpaceStationTM    GREEN TECHNOLO GYSpaceStation sensors can be  configured  to  operate with  any  number  of sensors  and  control  any number of lighting circuits as  one  system  for  any sized  room  application.v.092611–SSSS2000
Step 1: Sensor MountingA.  Determine mounting location within room or area to be covered.  Center the sensor within the center of the room/area when possible.  Loosen front knobs.B.  Slide to adjust the four (4) room control panels to the distance indicated to match the distance in feet between the sensor and each of the room wall (to allow activation from any movement within that room area).Loosen Front Knobs to Slide PanelsSlide All Four Panels to the Match the Distancein Feet Between Sensor and Room WallsInstructionsSpaceStationi2TMPhone:  605.542.4444     INSTALLATION |  Sensor Mounting WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials.       Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty.Adjustable Range Control Panels (RCP) controls exact cut off range of each roomROOM WIDTHROOM LENGTHRoom Area Range Coverageat Sensitivity % SettingCeiling Height8 Feet10% 35% 50% 75% 100%10 Feet12 Feet7'x 7'8'x 8'9'x 9'12'x 12'20'x 20'10'x 10'13'x 13'17'x 17'22'x 22'9'x 9'12'x 12'20'x 20'25'x 25'9'x 9'8'x 8'Area Sensitivity Adjustment  (SpaceStation Centered in Room)Note:  Maximum 60' Height Provides Maximum Range Coverage to 50 x 50 Feetv.092611–SS
3TMPhone:  605.542.4444     INSTALLATION | Sensor AdjustmentsWARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials.    Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty.InstructionsSpaceStationiSTEP 2: SENSOR ADJUSTMENTS A. Detection Area Detection are can be reduced by selecting the combination on the DIP switches to fit precisely for each specific application.B. Hold TimeHold-time means the time period you would like to keep the lamp on after the person has left the detected area.C. Daylight Sensor (Remote Option Only)The sensor contains a daylight sensor in order to allow a function only below a defined brightness threshold.  BRIGHTNESS THRESHOLD SETUP – DAYLIGHT:  The lamp works always, even during daylight.Note: Three switches should be put in OFF position when remote day light sensor is not installed.  2O FC5O FC200 FC300 FCDISABLEDETECTION AREA12 3 12 3 12 3HOLD TIMEDAYLIGHT SENSORIIIIIIIVVIIIIIIIVVIVIIIIIIIVV100%75%50%30%10%5 S30 S180 S300 S15 MIN25 MINON ON ONSensor Adjustmentsv.092611–SS
Accessible Ceiling Installation:  Note: T-Bar Option - Suspended Accessible Ceilings  Use optional T-bar bracket for support mounting to inverted T-grid lay in suspended ceilings.    InstructionsSpaceStationiTMPhone:  605.542.4444     INSTALLATION | New Construction & RetrofitWARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials.    Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty.Inccessible Ceiling Installation:  Note:  Use Optional arm bracket for support mounting to structural blocking or stud also for retrofit installation through existing ceiling hole (see page 8 also).ARM Option - Gypsum Board and Other Inaccessible Ceilings 4ARM Adjustable Remote Mounting to structural / blocking tosecure SpaceStationv.092611–SS
5InstructionsPower ConnectionsiTMPhone:  605.542.4444     INSTALLATION | Single Wiring Control Wiring DiagramWARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials.    Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty.Single Lighting Circuit Control Wiring DiagramNeutralLoad OutputLine Input BlackLine BlackLoad RedNeutral WhiteYellowBlueSpaceStation Occupancy SensorSTEP #3:  Provide Power ConnectionsBranch circuit: building power only connections. Provide 120 VAC or 277 VAC uninterrupted power connections to terminate within the ceiling mounted bracket junction box. Black - Line InputWhite - NeutralRed - Line Output to Load  Load must not exceed 800 watts @ 120 VAC. Load must not  exceed 1200 watts  @  277 VAC. Loads in excess  must  use  the  Command  Module  option  for higher wattage.Note: Dimming ballast circuits must be controlled by the Command Module option.  CLoadOption (RDS)B Optional:Remote Daylight SensorOverride FDPConcealed Wall SwitchOptional:AOption (OR)A – Optional   B – Optional  C – Load Informationv.092611–SS
InstructionsPower ConnectionsiTMPhone:  605.542.4444     WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials.    Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty.INSTALLATION | Multiple Wiring Control Wiring DiagramMultiple Lighting Circuit Control Wiring Diagram*Required for two or more circuitsOption (RDS)YellowBlueLine Input NeutralLine BlackNeutral WhiteNeutral WhiteLoad Output RedCommand Module (CM) –  # of polesi.e. CM04 - 4 lighting circuit polesATTENTION!Verify line voltage is compatible with electrically held coil voltage (120 VAC or 277 VAC)Specified: # of 20 AMP Circuits6Load must not exceed 800 watts @ 120 VAC. Load must not exceed 1200 watts @ 277 VAC. Loads in excess must use the Command Module option for higher wattage.§Command Module option.  Dimming  ballast  circuits  must  be  controlled  by  the §Parallel connect multiple (two or more) sensors for areas exceeding range coverage of one lighting sensor.SpaceStation Occupancy SensorOverride FDPConcealed Wall SwitchOptional:AA – Optional   B – Optional  C – Load Information  D – Command Module InformationCBDOption (OR)LoadOptional:Remote Daylight SensorTWO OR MORE SENSORS OPERATING TOGETHERv.092611–SS
InstructionsPower Connectionsi7TMPhone:  605.542.4444     INSTALLATION | Adjustable Remote Mounting (ARM)WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials.    Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty.ARM – Adjustable Remote MountingARM Adjustable Remote Mounting to structural / blocking tosecure SpaceStationProvide flexible conduit connections to existingLighting Branch CircuitExisting Ceiling OpeningLighting Branch CircuitLighting Branch CircuitExisting Light Fixture, J Box or Access panelExisting CeilingSpace Station SensorNote: Dimming ballast circuits must be controlled by the Command Module option.  The minimum size opening is 4 inches in diameter for insertion of SpaceStation into an inaccessible ceiling openingv.092611–SS
Time DelayIMPORTANT START-UP INFORMATIONThe first time the sensor is powered-up the load will flash ON then OFF once, then there will be 10 seconds while the sensor warms-up.The SpaceStation automatically turns OFF the load after the coverage area has been vacant for the amount of time set in the time delay. The minimum setting is 10 seconds, maximum is 30 minutes. TROUBLESHOOTING Quick Test: Turn the time delay to minimum. Move out of the sensor's view.  Lights should turn OFF after 10 seconds. Move into the sensor's view.  The lights should turn ON.Lights do not turn OFF:1. If there is no motion in the set coverage area, reduce the sensitivity varying room panel adjusted positions.2. Verify room panel adjustment positions.3. Verify time delay and that there is no movement within the sensor's view for that time period.FCC NOTICEThis device complies with part 15 of the FCC Rules, Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Warranty All Concealite fixtures are tested and are guaranteed to be free from defective materials and workmanship for a period of three years from date of shipment under normal operations and proper use.   Correction of all defects shall be by replacement or repair (at our option) and shall constitute fulfillment of all manufacturer's obligations.   We will not allow any charge for labor, materials, etc that does not have our written approval before the work is begun.  Damage incurring in handling or in transit are not covered by this guarantee.   Any other warranty, expressed or implied, is hereby void.   Modifications or changes to the product or failure to follow installation instructions will void the warranty. TMPhone:  605.542.4444     TroubleshootingInstructionsTroubleshootingi8v.092611–SS