USER MANUAL FOR COMFLEX-4300        DDIISSTTRRIIBBUUTTEEDD  AANNTTEENNNNAA  SSYYSSTTEEMM  USER MANUAL ComFlex-4300 QE: 1-0-0            Comba Telecom Ltd. ComFlex-4300
USER MANUAL FOR COMFLEX-4300       The information contained herein is the responsibility of and is approved by the following, to whom all enquiries should be directed in the first instance:  This is an unpublished work the copyright in which vests in Comba International ("Comba"). All rights reserved.  The information contained herein is confidential and the property of Comba and is supplied without liability for errors or omissions. No part may be reproduced, disclosed or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 3  0.1   CONTENTS  Section Page 0.1 CONTENTS ....................................................................................................................................................... 3 0.2 INDEX TO FIGURES AND TABLES ...................................................................................................................... 4 0.3 HISTORY ........................................................................................................................................................... 6 0.4 GLOSSARY OF TERMS ....................................................................................................................................... 7 0.5 SAFETY NOTICES AND ADMONISHMENTS ....................................................................................................... 8 1 GENERAL INFORMATION .............................................................................................................................. 9 2 EQUIPMENT DESCRIPTION .......................................................................................................................... 11 2.1 SYSTEM DIAGRAM ......................................................................................................................................... 11 2.2 TYPICAL APPLICATION ................................................................................................................................... 11 2.3 EQUIPMENT CONSTITUTION ......................................................................................................................... 12 2.4 KIT OF PART ................................................................................................................................................... 13 3 INSTALLATION ............................................................................................................................................ 15 3.1 WARNINGS AND ALERTS ................................................................................................................................ 15 3.2 SITE PLANNING CONSIDERATIONS ................................................................................................................ 16 3.3 INSTALLATION PROCEDURES ......................................................................................................................... 18 3.4 EQUIPMENT CONNECTORS ........................................................................................................................... 26 3.5 EQUIPMENT CONNECTION ............................................................................................................................. 30 4 COMMISSIONING ....................................................................................................................................... 35 4.1 PRE-COMMISSIONING TASKS ........................................................................................................................ 35 4.2 LED INDICATORS ............................................................................................................................................ 35 4.3 DIGITAL DISPLAY INDICATORS ....................................................................................................................... 36 4.3.1 DIGITAL DISPLAY ON RFU .......................................................................................................................... 36 4.3.2 DIGITAL DISPLAY ON FOU.......................................................................................................................... 36 5 WEB GUI ..................................................................................................................................................... 38 5.1 WEB GUI CONNECTION ............................................................................................................................... 38 5.2 WEB GUI INTRODUCTION ........................................................................................................................... 39 5.2.1 [DEVICES] ............................................................................................................................................... 39 5.2.2 [COMMISSIONING] ................................................................................................................................ 44 5.2.3 [FIRMWARE] .......................................................................................................................................... 44 5.2.4 [MANAGEMENT] .................................................................................................................................... 46 5.3 COMMISSIONING PROCEDURE ................................................................................................................... 54 6 ALARMS AND TROUBLESHOOTING ............................................................................................................. 62 6.1 ALARMS ...................................................................................................................................................... 62 6.2 TROUBLESHOOTING ................................................................................................................................... 63 7 APPENDICES ............................................................................................................................................... 64 7.1 APPENDIX A: TOOLS FOR INSTALLATION AND MAINTENANCE .................................................................... 64 7.2 APPENDIX B: RMA (RETURN MATERIAL AUTHORIZATION) ......................................................................... 65
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 4   0.2  INDEX TO FIGURES AND TABLES Figure 1: Master Unit (MU) ........................................................................................................................................ 9 Figure 2: Remote Unit (RU) ..................................................................................................................................... 10 Figure 3: System Diagramc ..................................................................................................................................... 11 Figure 4: Typical Application ................................................................................................................................... 11 Figure 5: ComFlex Master Unit ............................................................................................................................... 18 Figure 6: RF Unit Installation ................................................................................................................................... 19 Figure 7: FOU Installation ........................................................................................................................................ 19 Figure 8: PSU Installation ........................................................................................................................................ 20 Figure 9: Mounting Rack .......................................................................................................................................... 20 Figure 10: Angle Iron Installation ............................................................................................................................ 21 Figure 11: MU Installation ........................................................................................................................................ 21 Figure 12: Secure the Enclosure ............................................................................................................................ 21 Figure 13: Finish Installaiton ................................................................................................................................... 22 Figure 14:  Install Mounting Rack on the Wall ...................................................................................................... 23 Figure 15: Hang RU onto the Mounting Rack ....................................................................................................... 23 Figure 16: Tighten the Screws at the Bottom of RU ............................................................................................ 24 Figure 17: MU Front Panel Connectors ................................................................................................................. 27 Figure 18: MU Rear Panel Connectors ................................................................................................................. 27 Figure 19: Mini Din Female Dimension ................................................................................................................. 28 Figure 20: RU Connectors ....................................................................................................................................... 28 Figure 21: MU Grounding (MU Rear Panel) ......................................................................................................... 30 Figure 22: RU Grounding ......................................................................................................................................... 31 Figure 23: Fiber Optical and RF Port Connection ................................................................................................ 31 Figure 24: MU Power Connection (Rear Panel) ................................................................................................... 32 Figure 25:  RU Fiber Optical and RF Port Connection ........................................................................................ 33 Figure 26:  Pins Allocation for “EXT_ALM” Port for RU ...................................................................................... 33 Figure 27: Pins Allocation for “BTS_ALM” Port .................................................................................................... 34 Figure 28: RFU Digital Display ................................................................................................................................ 36 Figure 29: Optical Port No. and Digital Display .................................................................................................... 37 Figure 30: PC IP Address Setting........................................................................................................................... 38 Figure 31: Input IP Address ..................................................................................................................................... 38 Figure 32: Input User Name and Password .......................................................................................................... 39 Figure 33: Web GUI Main Screen .......................................................................................................................... 39 Figure 34: [Devices] Sceen ..................................................................................................................................... 40 Figure 35: MU Device - Monitoring Unit ................................................................................................................ 40 Figure 36: MU Device - Optical Unit ....................................................................................................................... 41 Figure 37: MU Device - RF Unit .............................................................................................................................. 41 Figure 38: RU Device ............................................................................................................................................... 42 Figure 39: RU Device – 700 .................................................................................................................................... 43 Figure 40: RU Device – External Alarm ................................................................................................................. 43 Figure 41: RU Device – Fan Alarm ........................................................................................................................ 44 Figure 42: [Commissioning] Screen ....................................................................................................................... 44 Figure 43: [Firmware] Screen – Upgade ............................................................................................................... 45 Figure 44: [Firmware] Screen – Pop-up Window 1 .............................................................................................. 45 Figure 45: [Firmware] Screen – Pop-up Window 2 .............................................................................................. 45 Figure 46: [Firmware] Screen – Swap ................................................................................................................... 46 Figure 47: [Firmware] Screen – Module Upgrade ................................................................................................ 46 Figure 48: [Management] Sceen ............................................................................................................................ 47 Figure 49: Management – Import&Export ............................................................................................................. 47 Figure 50: Management – IP Setting ..................................................................................................................... 48 Figure 51: Management – Comm. Setting ............................................................................................................ 49 Figure 52: Management – Maintenance Setting .................................................................................................. 49 Figure 53: Management – Security ........................................................................................................................ 50
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 5  Figure 54: Modify Password .................................................................................................................................... 50 Figure 55: Management – Device Reset ............................................................................................................... 51 Figure 56: Management – PA Reset ...................................................................................................................... 51 Figure 57: Management – Device Info ................................................................................................................... 52 Figure 58: Management – Device Scanning ......................................................................................................... 52 Figure 59: Management – Device Remove .......................................................................................................... 53 Figure 60: Management – Report........................................................................................................................... 53 Figure 61: Management – License ......................................................................................................................... 54 Figure 62: Management – Alarm Log .................................................................................................................... 54 Figure 63: Commissioning Procedure - Start........................................................................................................ 55 Figure 64: Commissioning Procedure – Device Scan ......................................................................................... 55 Figure 65: Commissioning Procedure – Params Setting .................................................................................... 56 Figure 66: Dev Info & Date/Time ............................................................................................................................ 56 Figure 67: Commissioning Procedure – MU Calibration ..................................................................................... 57 Figure 68: Commissioning Procedure – MU Calibration Finish ......................................................................... 57 Figure 69: Commissioning Procedure – RU Calibration ..................................................................................... 58 Figure 70: Commissioning Procedure – RU Calibration Finish .......................................................................... 58 Figure 71: Commissioning Procedure – MU Setup ............................................................................................. 58 Figure 72: MU Frequency Band Table ................................................................................................................... 59 Figure 73: Commissioning Procedure – RU Setup .............................................................................................. 59 Figure 74: RU Frequency Band Table ................................................................................................................... 60 Figure 75: Commissioning Procedure – Finish .................................................................................................... 60             Table 1: MU Components ........................................................................................................................................ 12 Table 2: RU Components ........................................................................................................................................ 12 Table 3: Master Unit (MU) KOP .............................................................................................................................. 13 Table 4: Remote Unit (RU) KOP ............................................................................................................................ 14 Table 5: MU Connections ........................................................................................................................................ 27 Table 6: RU Connections ......................................................................................................................................... 29 Table 7: Pin Definition of “EXT_ALM” Port for RU ............................................................................................... 33 Table 8: Pin Definition of “BTS_ALM” Port............................................................................................................ 34 Table 9: MU LED Indications .................................................................................................................................. 35 Table 10: RU LED Indications ................................................................................................................................. 35 Table 11: RFU Digital Display ................................................................................................................................. 36 Table 12: FOU Digital Display ................................................................................................................................. 37 Table 13: Import/Export Parameters ...................................................................................................................... 48 Table 14: MU Alarm List .......................................................................................................................................... 62 Table 15: RU Alarm List ........................................................................................................................................... 62 Table 16: MU Alarms Diagnosis ............................................................................................................................. 63 Table 17: RU Alarms Diagnosis .............................................................................................................................. 63
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 6   0.3  HISTORY  Change No. ENU Details Of Change  1  1-0-0 This user manual first created in Jul 2014.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 7   0.4  GLOSSARY OF TERMS ALC   Automatic Level Control ATT   Attenuation   BDA Bi-direction Amplifier BS   Base Station   BTS   Base Transceiver Station   DL   Downlink   DT  Donor Terminal   FOU Fiber Optical Unit GUI Graphic User Interface ID   Identification LNA   Low Noise Amplifier   MCU   Main Control Unit MT   Mobile Terminal   MTBF   Mean Time Between Failures   MU Master Unit NC   Normally Closed   NF   Noise Figure   NO   Normally Open   OMC   Operation & Maintenance Center   OMT   Operation & Maintenance Terminal   OP Optical Fiber OPEX OperatingExpense PA  Power Amplifier   PIM Passive Inter Modulation PLL   Phase Locked Loop   POI Point of Interconnects PSU   Power Supply Unit   RF  Radio Frequency   RFU  Radio Frequency Unit  RU Remote Unit SMA   Sub-Miniature “A” Connector TX/RX Transmit/Receive UL   Uplink   VAC   Volts Alternating Current   VSWR   Voltage Standing Wave Ratio   WCDMA Wideband Code Division Multiple Access
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 8  0.5   SAFETY NOTICES AND ADMONISHMENTS This document contains safety notices in accordance with appropriate standards. In the interests of conformity with the territory standards for the country concerned, the equivalent territorial admonishments are also shown.  Any installation, adjustment, maintenance and repair of the equipment must only be carried out by trained, authorized personnel. At all times, personnel must comply with any safety notices and instructions.  Specific hazards are indicated by symbol labels on or near the affected parts of the equipment. The labels conform to international standards, are triangular in shape, and are coloured black on a yellow background. An informative text label may accompany the symbol label.  Hazard labeling is supplemented by safety notices in the appropriate equipment manual. These notices contain additional information on the nature of the hazard and may also specify precautions.   CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the product.  NOTE: Note: The grantee is not responsible for any changes or modifications not expressly approved by the  party responsible  for  compliance.  Such  modifications  could  void  the  user’s  authority  to  operate  the equipment.   This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)  this  device  may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any  interference received, including interference that may cause undesired operation   To comply with FCC RF exposure compliance requirements, each individual antenna used for this transmitter must be installed to provide a separation distance greater than 159.13cm or more from all persons during normal operation and must not be co-located with any other antenna for meeting RF exposure requirements.   WARNING! This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have and FCC LICENSE or express consent of an FCC License to operate this device. Unauthorized use may result in signification forfeiture penalties, including penalties in excess of $100,000 for each continuing violation.  NOTE: A readily accessible disconnect device shall be incorporated external to the equipment.     End of Section
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 9    1  GENERAL INFORMATION The ComFlex-4300 Distributed Antenna System (hereinafter called “ComFlex”) consists of Master Unit (MU) and Remote Unit (RU). The MU includes the MU Chassis, Power Supply Unit (PSU), Fiber Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is a module design which supports 4 independent bands, 700MHz (lower ABC)/700MHz (upper C), 850MHz, 1900MHz and AWS band. The low signal transmission loss of optical fiber is applicable for long distance transmission. ComFlex can support the optical transmission of up to 6.5dBo optical loss, equivalent to 8 miles fiber length.   Main feature:    Modularized Master Unit supports flexible field upgrade and maintenance.   Independent gain control for each RF source.  High MTBF and low noise design with modular PSU and convection cooling.   RF module supports both simplex and duplex.  Supports multi-operator and mix mode application.  Optical link auto gain control.  Web based GUI for intelligent commissioning and configuration.  The figures below show the ComFlex Master and Remote unit enclosure.      Figure 1: Master Unit (MU)
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 10    Figure 2: Remote Unit (RU)    End of Section
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 11   2  EQUIPMENT DESCRIPTION 2.1  SYSTEM DIAGRAM Optical FiberMU AntennaRUBTS or BDA  Figure 3: System Diagramc  On the DL, signals from the BTSs or BDA are converted into optical signals after amplification in the MU.Then the optical signals are transmitted to the RU via optical fiber. The Optical TX/RX Module of RU converts the DL optical signals into RF signals. After amplification, the signals are transmitted from RU ANT port to the service antenna using 50Ohm coaxial cable.   On the UL, the signals transmitted by the mobile are converted into optical signals, and then via the UL optical fiber, the signals are transmitted to MU, which then converts the optical signals back to RF signals and send to BTS or BDA via 50Ohm coaxial cable.   2.2  TYPICAL APPLICATION Shown below are the typical SISO and MIMO applications of MU and RUs.   …BTS(optional)DAS TraySISO SystemHRU 1 HRU 2 HRU 8BTS(optional)DAS TrayMIMO System…HRU 1A HRU 1B HRU 4A HRU 4B  Figure 4: Typical Application
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 12   2.3  EQUIPMENT CONSTITUTION MU consists of the following parts:  Table 1: MU Components Module Description MU01-RACK Master Unit Chassis includes eight slots for RF Unit, two slots for Fiber Optical Unit, and one slot for Power Supply Unit. MU01-PSU iDAS Master Unit Power Supply Unit (PSU) converts the input voltage into stable DC to supply power for other modules of Master Unit. MU01-FOU Master Unit Fiber Optical Unit (FOU) completes optical signal and RF signal conversion. One FOU has four optical ports, which means each FOU can support up to four RUs. MU01-RFU Master Unit RF Unit completes separation and combination of uplink and downlink signal with independent gain control, supports either simplex or duplex.  RU consists of the following parts:  Table 2: RU Components Module Description LRU01-4300 Remote Unit; A module design which supports 5 bands, including 700MHz (lower ABC, upper C), 850MHz, 1900MHz and AWS band.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 13   2.4 KIT OF PART Table 3: Master Unit (MU) KOP Item Qty Image MU Chassis 1  RF Unit (RFU) 1~8  Fiber Optical Unit (FOU) 1~2  Power Supply Unit (PSU) 1  Power Supply Cable (13 Feet 1 inch) 1  Communication Cable 1  Right Angle  Bracket (for MU 19“rack mounting) 1   Left Angle  Bracket (for MU 19“ rack mounting) 1
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 14  Table 4: Remote Unit (RU) KOP Item Qty Image Remote Unit 1  Mounting Bracket (used for both pole and wall installations)  1   Nuts M8, Spring Washers Φ8, Plain Washers Φ8 (used for securing Remote Unit when hanged on bracket protrusions) 2 pieces each   Masonry Bolt (set) M10x110 – used for wall mount installations 6   Hose Clamp (Φ30-Φ125) - used for pole mount installations (2 per bracket) 5   Optical Connector 2 - Power Supply Cable (AC) 1  Copper Grounding Wire (2m) 1  RJ45 Ethernet Communication Cable 1  Key – used for opening unit panels for access to internal components. 1   End of Section
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 15   3  INSTALLATION 3.1  WARNINGS AND ALERTS Laser   Laser light can cause damage to eyes. Laser light is not visible. Viewing it directly does not cause pain. The iris of the eye will not close when viewing a bright light. Consequently, serious damage to the retina of the eye is possible. NEVER LOOK INTO THE END OF A FIBER WHICH MAY HAVE A LASER COUPLED TO IT.    Radio Frequency Energies  There may be situations, particularly for workplace environments near high-powered RF sources, where recommended limits for safe exposure of human beings to RF energy could be exceeded. In such cases, restrictive measures or actions may be necessary to ensure the safe use of RF energy.   High Voltage  The equipment has been designed and constructed to prevent practicable danger, as far as reasonably possible. Any work activity on or near equipment involving installation, operation or maintenance must be free from danger, as far as reasonably possible.   Where there is a risk of damage to electrical systems involving adverse weather, extreme temperatures, wet, corrosive or dirty conditions, flammable or explosive atmospheres, the system must be suitably installed to prevent danger.   Protective Earthing  Equipment provided for the purpose of protecting individuals from electrical risk must be suitable for the purpose and properly maintained and used.    Handling Precautions  This covers a range of activities including lifting, lowering, pushing, pulling, carrying, moving, holding or restraining an object or person. It also covers activities that require the use of force or effort, such as pulling a lever, or operating power tools.   Electrostatic Discharge (ESD)  Observe standard precautions for handling ESD-sensitive devices. Assume that all solid-state electronic devices are ESD-sensitive. Ensure the use of a grounded wrist strap or equivalent while working with ESD-sensitive devices. Transport, store, and handle ESD-sensitive devices in static-safe environments.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 16   3.2  SITE PLANNING CONSIDERATIONS 3.2.1 SITE PLANNING Site Considerations  The MU is designed to be located indoors to facilitate coupling of BTS signals and power supply connections. The input range of MU RF unit is 10~30 dBm.   The site consideration for RU is listed below:    The distance between the service antenna of RU and coverage area should satisfy line of sight requirements for maximum coverage area.   The maximum fiber length is 8 miles, with a maximum path loss of 6.5dBo.   The system delay of the optical system must be taken into consideration when there are neighboring BTS sites overlapping in coverage.   Installation Location  Mounting surface shall be capable of supporting the weight of the equipment.  In order to avoid electromagnetic interference, a proper mounting location must be selected to minimize interference from electromagnetic sources such as large electrical equipment.   Environmental  Humidity has an adverse effect on the reliability of the equipment. It is recommended to install the equipment in locations having stable temperature and unrestricted air-flow.   The installation location for the system should be well ventilated. The equipment has been designed to operate at the temperature range and humidity level as stated in the product specifications.   Powering   The power supply unit (PSU) provides power to all modules within the equipment. Depending on the product variant, it is recommended that the PSU operates on a dedicated AC circuit breaker or fused circuit.   Grounding Requirement  Verify that the equipment has been well grounded. This includes antennas and all cables connected to the system. Ensure lightning protection for the antennas is properly grounded.    Cable Routing  Depending on equipment configuration, a variety of types of cables are connected to the MU and RU: coaxial cables, optical fibers, power cable, communication cable, and commissioning cable. Where applicable, ensure cables are properly routed and secured so that they are not damaged.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 17  Manual Handling  During transportation and installation, take necessary handling precautions to avoid potential physical injury to the installation personnel and the equipment.   3.2.2 SYSTEM INSTALLATION CHECKLIST  Working space available for installation and maintenance for each mounting arrangement. Ensure unrestricted airflow.   Ensure earthing point is within reach of the ground wire. (2m; 6 ft. 10 in.).    Ensure a power source is within reach of the power cord and the power source has sufficient capacity.    Where appropriate, ensure unused RF connectors are terminated.    Where appropriate, ensure unused optical fiber connectors are protected.    Do not locate the equipment near large transformers or motors that may cause electromagnetic interference.    Reduce signal loss in feeder cable by minimizing the length and number of RF connections.    Ensure the equipment will be operated within the stated environment (refer to datasheet).    Where needed, couple BTS RF signal with a coupler to prevent damaging the equipment.    Where appropriate, confirm available of suitably terminated grade of RF and optical fiber.     Observe handling of all cables to prevent damage.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 18  3.3  INSTALLATION PROCEDURES 3.3.1 GOODS INWARDS INSPECTION ComFlex was factory tested, inspected, packed, and delivered to the carrier with utmost care. Do not accept shipment from carrier which shows damage or shortage until the carrier’s agent endorses a statement of the irregularity on the face of the carrier’s receipt. Without documentary evidence, a claim cannot be processed.  Open and check each package against the packing list. For any shortage, contact Comba Telecom Systems. Do not remove items from packing materials until installation.    3.3.2 TOOLS See Appendix A for a full list of tools required for installation and maintenance.   3.3.3 PREPARATION Optical Fiber:    Fiber optic cables require proper handling. Do not stretch, puncture, or crush the fiber cable(s) with staples, heavy equipment, doors, etc.    Always maintain the minimum bending radius specified by the cable manufacturer. The minimum bend radius is usually 10 times the cable’s outer diameter. In the case of single optical fiber that is not in a cable, the minimum bending radius to be observed is 3cm. (1.2”)    3.3.4 MU ASSEMBLING  ComFlex Master Unit consists of 4 parts: Chassis, RFU, FOU and PSU. All the units are packed separately. Follow the steps below to assemble.  Figure 5: ComFlex Master Unit
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 19  Step1: RF Unit installation: Remove RFU slot cover plate on Chassis, insert RFU and fasten the screws. (Each Unit can be installed in any one of eight RFU slots)   Figure 6: RF Unit Installation  Step2: FOU installation: Remove FOU slot cover plate on Chassis, insert FOU and fasten the screws. (Each Unit can be installed in either one of two FOU slots)     Figure 7: FOU Installation  Step3: PSU installation: Remove PSU slot cover plate on the right side of Chassis, insert PSU and fasten the screws.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 20    Figure 8: PSU Installation   3.3.5 MU IN 19” RACK MOUNTING MU is an indoor type device; the installation procedures are shown as below:  Step 1: Install right angle bracket and left angle bracket on back of the mounting rack. (Rack nuts and screws are not provided.) Use rack nuts and screws as recommended by rack manufacturer.    Figure 9: Mounting Rack
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 21   Figure 10: Angle Iron Installation  Step2: Slide the MU on to the angle brackets and confirm it is level.   Figure 11: MU Installation  Step 3: Attach the MU onto the rack with the recommended rack screws.   Figure 12: Secure the Enclosure
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 22  Step 4: Finish installation.    Figure 13: Finish Installaiton   3.3.6 RU WALL MOUNTING RU wall mounting steps are shown below.  Step 1: Select the wall mount location according to the following criteria:   General surroundings   Ventilated and easy-to-reach area (for maintenance and on-site inspection)   Proximity to DAS antenna in order to minimize cable loss  Step 2: Using the mounting bracket top and bottom mounting holes as a guide     Measure and mark the location for drilling the (supplied) M10 Masonry bolts (Φ12) in the wall (6 per bracket and drill the holes).  Using an electric drill with a Φ12 head, drill the holes for the Masonry Bolts.  NOTE: The ComFlex remote unit is mounted vertically with the connectors facing downwards.   Step 3: Using 6 (M10x110) Masonry bolts per bracket – secure the Mounting Brackets to the wall with the protruding M8 nuts facing towards you. The remote unit will be hung on these.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 23                               Figure 14:  Install Mounting Rack on the Wall  Step 4: Connectors facing down carefully fit and hang the GX unit on to the M10 bolts protruding from the top, middle and bottom parts of the mounting bracket.       Figure 15: Hang RU onto the Mounting Rack
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 24  Step 5: Using a spanner or wrench, tighten the two (2) M8 nuts on the top and bottom of the mounting bracket as shown below.   Figure 16: Tighten the Screws at the Bottom of RU  Step 6: Check enclosure position and verify that unit is mounted securely to the wall. .  3.3.7  Pole Mount Installation Step 1: Select the appropriate location according to the following criteria:   Accessibility     Antenna location and distance   Proximity to the antenna in order to minimize cable loss  Step 2: Secure the mounting bracket by slipping the 5 hose clamps (provided) through the mounting bracket and tighten securely.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 25            Step 3: Connectors facing downwards, hook the GX-Quad on to the top part of the bracket and then to the bottom.   Step 4: Using a spanner or wrench, tighten the two (2) M8 nuts on the top and bottom of the mounting bracket as shown below.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 26        3.4  EQUIPMENT CONNECTORS The figures below present the connectors of ComFlex MU.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 27  123456 7 8  Figure 17: MU Front Panel Connectors   9 10 11 12 1314  Figure 18: MU Rear Panel Connectors   Table 5: MU Connections Identifier Functional Description 1. OP1~OP4 SC/APC optical fiber access port 2. LED indicator LED indicator. See Chapter 4 for the description of each indicator.  3. BTS_ALM DB9-F connector for BTS alarm. 4. OMT RJ45 connector connects PC with equipment for local and remote monitoring. 5. LAN Reserved RJ45 port for remote monitoring. 6. TX/RX RF access port, Mini Din* female connector. 7. RX RF access port, Mini Din female connector. 8.   Digital display tube. See chapter 4 for the detailed description. 9.   Grounding connector. 10. FOU Communication port with extension optical unit.
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 28  11. AUX Reserved interface for source calibration unit. 12. 28 GND Provide 28V power supply for extension units (FOU and source calibration unit). 13. UL1,DL1; UL2,DL2; UL3,DL3 QMA female connector, reserved for RF interface of extended FOU and single soure calibration unit.  14. AC100~240V AC power supply connector.   *Mini Din Female Dimension is shown in figure below. M20X1 Figure 19: Mini Din Female Dimension    Figure 20: RU Connectors
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 29  Table 6: RU Connections Identifier Functional Description Service Connectors  (e.g. 850MHz, 700MHz, 1900MHz, AWS) DIN female connectors to antennas OP Corning OptiTap™ Fiber-optic waterproof connector to MU for either SM or MM fibers.  Power Connector  (side panel) Remote Power (AC) Power feed options: 100-240V 47-63 Hz Max Power Consumption: 1600W LAN RJ45 connector for local connection (i.e. debugging, troubleshooting) EXT_ALM External Alarm pin-out connectors supporting four external alarm connections SYS_ALM Pin-out connector supporting up to 3 relay alarms used for connecting the RU to a network or modem and relaying the status of the RU alarms  CPL_1  Coupler port - 1900MHz 50dB coupling CPL_2 Coupler port - AWS 50dB coupling CPL_3 Coupler port - 850MHz 50dB coupling CPL_4 Coupler port - 700MHz 50dB coupling
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 30     3.5  EQUIPMENT CONNECTION  3.5.1 GROUNDING CONNECTION    3.5.2 MU GROUNDING CONNECTION Step 1: Connect the GND cable to the GND connector and the building EARTH. Recommended GND cable size is # 12 AWG.  Step 2: Ensure the GND cable is connected to building GND.  Grounding Connector Figure 21: MU Grounding (MU Rear Panel)   3.5.3 RU GROUNDING CONNECTION Step 1: Connect one side of the supplied copper wire GND cable to right side of RU with two M6×10 hexagon Screws (screws are provided). Connect the other side of the supplied copper wire GND cable to the building EARTH with two M6 screws (screws are not provided).  Step 2: Connect one side of the supplied copper wire GND cable to RU with two M6×10 hexagon Screws (screws are provided). Connect the other side of the supplied copper wire GND cable to the building EARTH with two M6 screws (screws are not provided).  Step 3: Ensure all GND cables are well grounded to building GND.  WARNING! This unit must always be grounded. Consult an appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available.   Do not connect power before grounding.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 31      Figure 22: RU Grounding   3.5.4 MU CONNECTIONS Step1: Connect the MU OP (optical) port to one of the RU OP port. (NOTE: requires Single Mode fiber with SC/APC connectors; MAXIMUM OPTICAL LOSS = 6.5dBo)  Step 2: For duplex application, connect the MU RFU TX/RX port to the RF Source (BTS or BDA) using 50Ohm coaxial cable. For simplex application, connect the MU RFU TX/RX port to the RF Source downlink, and then connect MU RFU RX port with RF Source uplink. (NOTE: Coaxial cable must be mini-DIN Male on the MU side)   Local commissioning & Remote monitoring portBTS Alarm ReservedFiber optic portRF port, to BTSLED indicator  Figure 23: Fiber Optical and RF Port Connection
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 32      Step 3: Connect the power cable to the power supply port (100-240VAC, 1Amp maximum).   Power Connection  Figure 24: MU Power Connection (Rear Panel)   3.5.5 RU CONNECTION  Step 1: Connect the RU OP (optic) port to one of the OP port located on MU FOU front panel.  Step 2: Connect ANT port to a broadband antenna using 50Ohm coaxial cabel. Note: coaxial cable must be mini-D male on the RU side, antenna shoule be 50Ohm.   Step 3: Connect DC 28V port to RU Power Supply Unit DC 28V port.  Step 4: Connect power cable on PSU with the public power grid (110~220VAC, 3Amp maximum).
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 33      Figure 25:  RU Fiber Optical and RF Port Connection   3.5.6 RU EXTERNAL ALARM CONNECTION  For RU, this is a 4-pin connector. The following figure and table show the pin allocation and definition. Pin numbering are shown looking-into the connector on the enclosure.  1234 Figure 26:  Pins Allocation for “EXT_ALM” Port for RU  Table 7: Pin Definition of “EXT_ALM” Port for RU Pin number 1 2 3 4 Alarm definition EXT. Alarm 1 GND EXT. Alarm 2 GND  Note: Users need to configure Ext Alm 1~2 on WEB GUI to realize External Alarm (Refer to Chapter 5).    3.5.7 MU BTS ALARM CONNECTION The equipment alarms can be signaled to the BTS via voltage-free relay contacts. The voltage-free relay connections are connected to the DB-9 port “BTS_ALAM” located on the MU. The following figure and table show the pin allocation and definition.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 34     124356798BTS_OPENBTS_CLOSEBTS_ COM Figure 27: Pins Allocation for “BTS_ALM” Port  Table 8: Pin Definition of “BTS_ALM” Port Pin Number Definition Description 1 BTS_OPEN Connects to the open terminal of the voltage free relay. 2 BTS_COM  Connects to the common terminal of the voltage free relay. 3 BTS_CLOSE Connects to the close terminal of the voltage free relay. 4 ~ 9 NC Reserved.   3.5.8 CONNECT TO PC The local commissioning and management for MU and RU is achieved through connecting to the WEB base GUI.  Connect MU to PC  Connect MU “OMT” port (RJ45) to the RJ45 port of PC with supplied Ethernet cable to achieve local monitoring and management.   End of Section
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 35      4  COMMISSIONING 4.1 PRE-COMMISSIONING TASKS After equipment installation, perform the following steps before equipment powering and commissioning, check that the expected voltage, current, and power levels do not violate any ratings. Double check all connections including ground before applying power. Do not manipulate circuits or make changes when power is applied:    Visually inspect the power connection within the equipment. Ensure that all cables are correctly and securely connected, including power cables, grounding wires, RF cables and optical cables.    Check grounding connection and verify that the ground resistance is less than 5Ω.   Connect the equipment to the PC.    Power on MU and RU.   Monitor the initialization of the MU and RU though the LEDs on the panel. Refer to detailed LEDs information in the next section.   4.2   LED INDICATORS Diagnostic LEDs are located on the MU front panel and RU bottorm panel; each indicates the status of a particular function:  Table 9: MU LED Indications LED Indicator Normal Status Indication PWR Steady green Power indicator. If LED is off, it indicates the system has no power.  RUN Flashing green (1 time/sec) MU operation indicator. After initialization (1~2 minutes), the LED should flash at once per sec. (When upgrade firmware, LED will flash rapidly)  ALM OFF Alarm indicator. If LED is RED, there is an alarm. OP Steady green Located on Fiber Optical Unit (FOU), it is an indicator for receive optical power. If LED is off, it indicates the receiving optical power is less than -10dBm.  Table 10: RU LED Indications LED Indicator Normal Status Indication COMM. Blinking green (1 time/sec) BLINKING GREEN - Flashes (rate of flash per second) for the duration of 1 minute upon communication initialization RAPID/NO FLASH - Indicates communication fault RUN  Off OFF – Normal operation RED - Fault ALM Off Alarm indicator. If LED is RED, there is an alarm.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 36     4.3  DIGITAL DISPLAY INDICATORS 4.3.1  DIGITAL DISPLAY ON RFU The digital display tube on RFU shows the DL input power. The range of DL input power shown on the display tube is from -19 to 33 (dBm), when DL input powe is lower than -19dBm, it will show L, when DL input powe is higher than 33, it will display H.     Figure 28: RFU Digital Display  Table 11: RFU Digital Display  Figure DL Input Power Level L < -19dBm -19~33 -19~33dBm H >  33dBm   4.3.2  DIGITAL DISPLAY ON FOU The digital display tube on optical module has two digits.   The first digit will display A, b, C and d which presents the No. of optical port. Refer to below figure for the relationship.  The second digit will display the optical loss of each port. See the following table for the relationship of figure and optical loss.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 37     Ab C d  Figure 29: Optical Port No. and Digital Display  Table 12: FOU Digital Display  Figure Optical Loss 0~9 0~9dBo H >  9dBo   End of Section
USER MANUAL FOR COMFLEX-4300 ENU STATUS : 1-0-0 Copyright - refer to title page Page 38 Page  3838   5  WEB GUI ComFlex can be monitored and controlled by WEB GUI, follow below contents to achive system parameter setting and commissioning.    5.1  WEB GUI CONNECTION Step 1: Connect MU OMT port to PC RJ45 port with the supplied Ethernet cable to set up a physical connection.  Step 2: Go to laptop Control Panel\Network and Internet\Local Area Connection. Right click it and click Properties. Then follow the steps shown in figure below.                           Figure 30: PC IP Address Setting  Step 3: Open browser (browser IE7.0, IE8.0, Chrome or Firefox, suggest disply resolution is 1024×768), input Web GUI IP address: 192.168.8.101, click [Enter].    Figure 31: Input IP Address  Step 2: Input User Name: admin; Password (default password: admin). Click [Log in].
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 39      Figure 32: Input User Name and Password  5.2  WEB GUI INTRODUCTION After log in, the Web GUI main screen will appear.    Figure 33: Web GUI Main Screen  On Comba Web GUI Home page, there are four Menu bars:  [Devices], [Commissioning], [Firmware] and [Management].   5.2.1  [DEVICES] The [Devices] page shows the actual connection diagram of MU and RU.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 40      Figure 34: [Devices] Sceen  MU Main Management Screen  Figure 35: MU Device - Monitoring Unit
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 41     Fiber Optical Unit Management Screen   Figure 36: MU Device - Optical Unit  Note: MU transmit optical power is -4~-2dBm.   RF Unit Management Screen    Figure 37: MU Device - RF Unit
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 42     Remote Unit Management Screen  Click RU photo, users can visit RU directly. Make sure two steps are done before visit RU:   RU and MU are connected by optical fiber.   RU device scanning is done. Note: Go to [Commissioning] page or [Management] page for device scanning.    Figure 38: RU Device  NOTE: There are three statuses for PA Service: Normal, Recovery and Shutdown. If PA output power or reflected power exceeds the threshold (32dBm), software will trigger Recovery:    It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA Service Status will turn to Normal, if PA output power or reflected power is still over the threshold, PA Service Status will turn to Recovery again.   If PA output power or reflected power is still over the threshold after six times of PA Recovery, PA Service status will be Shutdown which will need to be reset manually. Reset at Management > PA Reset.  Click on a specific band on the left side of RU Device page, the corresponding band information will show.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 43       Figure 39: RU Device – 700                    Figure 40: RU Device – External Alarm
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 44       Figure 41: RU Device – Fan Alarm   5.2.2  [COMMISSIONING] A work flow of the commissioning process is shown on [Commissioning] page. Click the [Start] button, the software will guide you through the commissioning step by step. For details, please refer to chapter 5.3.   Figure 42: [Commissioning] Screen   5.2.3  [FIRMWARE] There are two functions on the [Firmware] bar: [upgrade] and [swap]. [Upgrade] is used to upgrade software, and [Swap] is to replace current firmware version to the previous one.  Follow steps shown in below figure to upgrade firmware.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 45       Figure 43: [Firmware] Screen – Upgade   Step 4: After clicking , a window will pop up and click .    Figure 44: [Firmware] Screen – Pop-up Window 1  Step 5: Wait for 2~4 minutes while MU/RU is being reset.   Figure 45: [Firmware] Screen – Pop-up Window 2  Step 6: Clear browsing history and cookies from browser.  NOTE: For MU software upgrade, users need to re-login Web GUI after reset is done.  Follow steps shown in below figure to Swap firmware.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 46      Figure 46: [Firmware] Screen – Swap    Figure 47: [Firmware] Screen – Module Upgrade   5.2.4  [MANAGEMENT] Other parameters can be configured on [Management] page.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 47      Figure 48: [Management] Sceen  There are thirteen function bar list in the left side of the [Mangement] page. Below figures are the introduction of each function bar.     Import&Export   Figure 49: Management – Import&Export   Blow table list the parameters that can be import/export:
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 48     Table 13: Import/Export Parameters Device Paremeter Device Parameter MU Alarm Enable RU Alarm Enable ATT value ATT value RF Switch RF Switch SNMP parameter Over temperature alarm threshold  DL over output power threshold  External Alarm level  Import and Export can help users quickly configure MU and RU parameters. For example, if one MU/RU finished configuration, users can export its parameters and save as a file in PC, and then import this file to other MU/RU to fast finish the MU/RU parameter setting.    IP Setting    Figure 50: Management – IP Setting  Note: For remote monitoring, the IP Address must be set correctly according to the location IP of remote connection. If more than one equipment is connected to the public network through the same router, the router’s local IP CANNOT be set as 192.168.8.*.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 49      Comm. Setting   Figure 51: Management – Comm. Setting    Maintenance Setting   Figure 52: Management – Maintenance Setting
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 50       Security    Figure 53: Management – Security  Click , [Modify Password] window will pop-up.    Figure 54: Modify Password  Note: Username cannot be modified.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 51      Device Reset    Figure 55: Management – Device Reset Note:  Device  Reset  process will last about 2~4 minutes. For MU monitor reset, users need to re-login WEB GUI.   PA Reset   Figure 56: Management – PA Reset  Note: PA will be turned off by software when PA output power or (VSWR) reflected power is exceed the threshold. Users need to reset PA after debugging.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 52      Device Info   Figure 57: Management – Device Info  Note: Users can input maximum 30 bytes characters in Device Info.   Device Scanning    Figure 58: Management – Device Scanning   Note: This Step is the same as step1 of [Commissioning]. Running scanning, software will allocate an ID to RU so that MU can identify and visit it.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 53      Device Remove    Figure 59: Management – Device Remove   Note: If the RU has been scanned and identified by MU, to remove the RU from the system,users must remove this RU on this [Device Remove] page, otherwise, RU will still be shown on the Home page and will trigger optical alarm.    Report   Figure 60: Management – Report
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 54      License    Figure 61: Management – License    Alarm Log    Figure 62: Management – Alarm Log   5.3  COMMISSIONING PROCEDURE To complete the installation and commissioning, users need to follow the steps below.   Step 1: Click Menu bar [Commissioning] on home page, a work flow will show up.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 55      Figure 63: Commissioning Procedure - Start  Step 2: Click   to start RU device scan, this step will take about 1 minute.   Figure 64: Commissioning Procedure – Device Scan  Step 3: Click   to enter to Params Setting page. Click , users can set the device information and system time.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 56      Figure 65: Commissioning Procedure – Params Setting   Figure 66: Dev Info & Date/Time  Dev Info mainly used to record device location and Date/Time provid a time reference. Mouse click the Config Value of Date/Time to auto receive the computer time.  NOTE: Make sure all the ANT ports of  RUs are connected with dummy load or antenna system before proceeding to step 4.   Step 4: Click   to enter to MU Calibratiion page after finishing Parems Setting.     Select a frequency band that need to calibrate from the table in the middle of the page.   Read Tip1 on the left side and click   of Tip 1   Input signal to a RF port of RFU which you want to calibrate.   Read Tip2 on the left side and enther the input power in the box (Suggested input power 10-30dBm). Input power has to be >10dBm for successful calibration.   Click  .
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 57       Tip of MU calibration finish will show up on the left of the page, and calibration results will show in the table.   NOTE: Each RFU needs to be calibrated; click “More” at last step of process to calibrate next RFU.   Figure 67: Commissioning Procedure – MU Calibration   Figure 68: Commissioning Procedure – MU Calibration Finish  NOTE1: Calibration is to adjust MU and RU gain to assure that make sure system gain is 20dB,  if the band have been calibrated, users can click   to skip the process; if the band never been calibrated, users click   in the step of MU Calibration and RU Calibration, software can still procede to the next step of MU and RU setup, but the system gain will be a little deviation with 20dB, so the final output power will be not same with the target DL output power.   NOTE2: If there are more than one same band access to MU, then each access need to be calibrated in MU  Calibration  step,  while  in  RU  Cablibration  step,  users  only  need  to  calibrate  the  band  one  time, because all the same band shares the same PA.    Step 5: Click   to enter to RU Calibratiion page, refer to step 4 to finish RU calibration.   NOTE1: Make sure the ANT port of RU is connected with dummy load or antennas before Calibration. Several RU can be calibrated simultaneously.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 58     NOTE2: You can calibrate one RU or calibrate all the RUs at one time. Click “site” in RU table to select all RUs.  Figure 69: Commissioning Procedure – RU Calibration   Figure 70: Commissioning Procedure – RU Calibration Finish  Step 6: Click   to enter to MU Setup page after finishing RU calibration.  Figure 71: Commissioning Procedure – MU Setup
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 59      Click  to set band related information.   Figure 72: MU Frequency Band Table  Three parameters need to be set in this step.    Operator Info: record the operator information of this RU unit.   RF Switch: Set the RF switch status of this RF unit.  DL  Input  Power:  Input  Power  of  the  BTS  signal  access  to  this  RF  unit.  Note:  ComFlex  system reaches  its rated  output  power  (30dBm)  when  input power  is  +10dBm,  if DL  Input Power is  over 10dBm, software will autoadjust the internal attenuator to make RU output power reach rated Power. (Input power range: 10-30dBm).  Step 7: Click   to enter to RU Setup page after finishing MU setup.    Figure 73: Commissioning Procedure – RU Setup  Click   to set band related information of RU.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 60      Figure 74: RU Frequency Band Table  Two parameters need to be set in this step.    RF Switch: Set the RF switch status of Remote Unit.   Target DL Output Power: Expected DL output power setting. Note: Rated output power of ComFlex system is 30dBm, when Target DL Output Power is set less than 30dBm, software will auto adjust RU gain to make the RU output power reach the expected Power.  Step 8: Click   to enter to [Finish] page after finishing RU setup. Click   to calibrate other bands. Click   if all bands’ clibration is done.   Figure 75: Commissioning Procedure – Finish  Note: As the system calibration process is calibrated for single channel, so if there is more than one same band input, because of the power superposition, the band total output power will higer than target DL output power after the calibration is complete.  The calibration work is mainly to set device to reach it’s theoretical gain, so when there are two or more same bands access into and they have the same input power level, each channel will reach it’s rated
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 61     power, so the total output power will be (input A+gain) + (inputB+gain)+…+(inputN+gain). For example, if there are two 1900MHz bands acess to MU, each has 10dBm input power, the total output power of RU 1900MHz will be 30dBm+30dBm=33dBm.  For Multi-channel same band access, 800+850 (which share the same PA) access and 700 Uper C + LowerABC (also shared PA), they all will have power superposition. In this situation, users need to adjust system gain manually; otherwise, the output power will be higher than 32dBm which will trigger alarms (See Chapter 6 for details).  Refer to the method below for the gain adjustment: Suppose a band with N independent inputs, each input signal power are all X dBm. Apparently, there exists the following relationship between input and output after finished auto communication on WEB GUI: X dBm + Gain = 30dBm, then the total output power for N channels access is X dBm + Gain + 10*Log(N) = 30 + 10*Log(N), so Users need to set 10*Log(N) RFU ATT on WEB GUI for each channel.      End of Section
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 62      6  ALARMS AND TROUBLESHOOTING 6.1  ALARMS  Table 14: MU Alarm List Alarm List Alarm Condition Over-Temperature Alarm   Alarm when equipment temperature is higher than the threshold, otherwise normal;   Alarm judgment period: 3 minutes by default;   Alarm threshold : 80℃ by default. Optical Tx Alarm   Alarm when Optical Transmiting power is lower than the threshold, otherwise normal;   Alarm judgment period: 3 minutes by default;   Alarm threshold: -7dBm by default. Optical Rx Alarm   Alarm when Optical received power is lower than the threshold, otherwise normal;   Alarm judgment period: 3 minutes by default;   Alarm threshold: -10dBm by default. DL Input Power Overload Alarm   Alarm when DL input power is higher than the threshold, otherwise normal;   Alarm judgment period: 3 minutes by default;   Alarm threshold: 32dBm by default.  Table 15: RU Alarm List Alarm List Alarm Condition External Alarm   Alarm status when the external terminals have the same H/L level with alarm level, otherwise normal;   Alarm period: 10s by default. Over-Temperature Alarm   Alarm when equipment temperature is higher than the threshold, otherwise normal;   Alarm judgment period: 3 minutes by default;   Alarm threshold : 80℃ by default. Optical Tx Alarm   Alarm When optical transmiting power is lower than the threshold, otherwise normal;   Alarm judgment period: 3 minutes by default;   Alarm threshold: 0dBm by default. Optical Rx Alarm   Alarm When optical receiving power is lower than the threshold, otherwise normal;   Alarm judgment period: 3 minutes by default;   Alarm threshold: -14dBm by default. PA Alarm   Alarm when any one of the PA Current Alarm,PA Over-temperature Alarm, PA DL output power overload Alarm, Reflection Power Alarm happens, otherwise normal;   Alarm judgment period: 3 minutes by default. DL Output Overload Alarm   Alarm when the DL output power is higher than the threshold, otherwise normal;   Alarm judgment period: 3 minutes by default;   Alarm threshold: 32dBm. Shutdown Alarm   Alarm when the PA status is off, otherwise normal;   Alarm judgment period: 10s by default. LNA Alarm   Alarm when LNA have problems, otherwise normal;   Alarm judgment period: 3 minutes by default.
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 63     6.2  TROUBLESHOOTING Following installation and commissioning, occasional operation tasks to handle alarms may be required:  Table 16: MU Alarms Diagnosis Alarm condition Diagnosis Over- Temperature alarm   Check device temperature on WEB GUI   If device temperature is over threshold, make sure environment temperature is within the envireonment temperature range that MU supported (0~40℃). Apply climatic protection to the system under severe environment. Optical TX Alarm   Test MU transmit optical power    Replace FOU if transmit optical power is less than -7dBm Optical RX Alarm   Use Optical Power Meter to test received optical power   If received optical power is lower than -10dBm, test whether RU transmit optical power is normal (3~5dBm)   Check if optical loss of fiber link is higher than 6.5dBo   Clean fiber connector with absolute ethanol  DL Input Power Overload Alarm  Test DL input power of MU, if it is higher than +33dBm, choose proper coupler to ensure the input power to MU is lower than +33dBm.  Table 17: RU Alarms Diagnosis Alarm condition Diagnosis External Alarm  Check to make sure if the external device connected is working normally Over- Temperature alarm   Check device temperature on WEB GUI   If device temperature e is over threshold, make sure environment temperature is within the envireonment temperature range that RU supported (-20~50℃).Apply climatic protection to the system under severe environment. Optical TX Alarm   Test RU transmit optical power    Replace FOU if transit optical power is less than 0dBm Optical RX Alarm   Use Optical Power Meter to test received optical power   If received optical power is lower than -14dBm, test whether MU transmit optical power is normal (-4~-2dBm)   Check if optical loss of fiber link is higher than 6.5dBo   Clean fiber connector with absolute ethanol  DL PA alarms  Check PA Service Status on WEB GUI RU page,    If it is [Recovery], reset PA on WEB GUI Management page, then read RU output power: If output power is exceed threshold, need to reduce gain or input power; if output power is normall, check whether antenna port VSWR is too high.   If it is [Shutdown], Refer to PA Shutdown Alram DL Output Power Overload Alarm   Check if output power is exceed the threshold (32dBm)   Decrease the gain to reduce the output power PA Shutdown Alarm   Make Sure the environment temperature is -20~50℃   Reset PA, if PA service status turns to [Recovery], and then refer to DL PA Alarms. If PA still shutdown, the PA module maybe damaged, please contact with Comba to replace the RU. LNA Alarm Uplink LNA modual damaged, please contact with Comba to replace the RU.  End of Section
USER MANUAL FOR COMFLEX-4300  ENU STATUS : 1-0-0 Copyright - refer to title page Page 64      7  APPENDICES  7.1   APPENDIX A: TOOLS FOR INSTALLATION AND MAINTENANCE The following tools (not included in package) are required for installation or routine maintenance:     Power Drill (for wall mount)   Adjustable Wrench (0.31 inch~0.79 inch)    Philips Screwdriver  Allen wrench (M6)  Signal generator support output power 10dB.   Site Master