Cognex Germany Aachen IBASE Bar code scanner base station User Manual 08 user guide

Cognex Ltd. Bar code scanner base station 08 user guide

08 user guide

COGNEX®DataMan® 8000 SeriesQuick Reference Guide
ii  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide  iiiGetting Started About DataMan 8000 • DataMan 8000 Accessories • Physical Layout of the Reader and the Base Station Page 41DataMan 8000 Software Overview of Setting Up the Reader • Install DataMan 8000 Software • Start the Setup Tool • Use the Setup Tool Menu Bar Page 102Connection Options Connecting through Ethernet • Troubleshooting an Ethernet Connection • Connecting through RS-232 • Keyboard Emulation • Connecting through USB3Using DataMan 8000 Series Wireless ReadersConnecting to a Wireless DataMan 8000 • Base Station Routing Capabilities • Buffering Data • Charging • Changing Batteries4Industrial Protocols, Compliance Information, Warnings and NoticesIndustrial Protocols • DataMan 8000 Reader and Base Station Specications •  Laser Information • Agency Compliance Statements6Reading Codes with the DataMan 8000Field of View and Reading Distances • Trigger Types5Page 16Page 26Page 41Page 45ii  DataMan 8000 Quick Reference Guide
      Ethernet       RS-232       USB            Wireless4  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   5About DataMan 8000The DataMan 8000 series of readers offers the industry’s most advanced technology for reading 1D and 2D codes regardless of size, quality, printing method or surface, and is the only handheld ID reader that offers Industrial Ethernet communication and liquid lens technology. The DataMan 8000 series is available in two models, each with patented 1DMax and 2DMax algorithms, liquid lens technology, and future-proof modular communication slide-ins with optional Industrial Ethernet capability.The DataMan 8500 readers use Cognex’s patented UltraLight® technology for superior image formation on any mark type and surface. UltraLight illumination provides dark eld, bright eld and diffuse lighting all in one electronically controlled light.The DataMan 8100 readers feature integrated bright eld illumination ideal for applications that require superior performance without specialty lighting.Both models are available with the following communication options:An intelligent base station is also provided when the DataMan 8000 reader uses the wireless communication module. The base station acts as a router between the reader and your computer or network.
POE AdapterCPS-AC-POE1A-xxSerial/USB slide-inDMCM-SERIALM-00Ethernet slide-inDMCM-ENETM-00Wireless slide-inDMCM-WLESSM-00Intelligent Base Station DMA-IBASE-00Wall MountDMA-WALL-8000-00Power Supply for base stationDMA-24VPWR-xxPower Supply for readerDM100-PWR-00POE AdapterCPS-24V-POE1POE AdapterCPS-24V-POE4Battery for the wireless readerDMA-HHBATTERY-00StandDM-STAND-00RS-232 coiled cable for reader, 2.5 mDM8000-RS232-02RS-232 coiled cable for reader, 5 mDM8000-RS232-05 USB cable, 2.5 mDM8500-USB-02USB coiled cable, 2.5 mDM8000-USBC-02Ethernet cable, 5 mDM8000-ECABLE-05Ethernet cable, 30 mDM8000-ECABLE-30PS/2 adapter cableDM700-PS2-00DataMan 8000 Reader CablesDataMan Base Station CablesRS-232 cable for base station, 5 mDMA-RS232-05•  USB cable for base station: Use any standard USB-A to USB-B 2.0 cable up to 3 meters•  Ethernet cable for base station: Use any standard CAT5/5e, SF/FTP or S/FTP cableEthernet cable, 2.5 mDM8000-ECABLE-026  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   7DataMan 8000 Accessories DataMan 8000 Accessories: Cables
Laser aimerUltraLight (DataMan 8500 only)Lanyard hookIndicator Light Trigger (press and hold to read)Communication moduleConnection point with the reader:•  pairing reader and base station•  non-wireless communication•  chargingRS-232 USBEthernet (with optional Class 3 PoE power)power plug (24V, max. 13W)spare battery charger status indicatorbase station status indicatorsspare battery chargerCommunication module insertion point8  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   9Physical Layout of the ReaderLASER LIGHT, DO NOT STARE INTO BEAMPhysical Layout of the Base Station
To be able to connect to your reader or base station on your computer, you must perform the following steps:1. Install the Setup Tool on your computer.2. Select the connection type: Ethernet, Serial, or USB.3. Connect the appropriate cabling.4. Power on your device(s).      Ethernet       RS-232       USB10  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   11Overview of Setting Up the ReaderRS-232/USB connectionInstall DataMan 8000 Software1.  Check the DataMan Release Notes for a full list of system requirements. 2.  Insert CD-ROM and follow the on-screen prompts.3.  Connect the DataMan 8000 to your PC. 4.  Launch the Setup Tool and click Refresh. The reader or the base station appears under COM ports or Network devices.5.  Select a COM port or a Network devices listing and click Connect. Ethernet connection“DM8_00” with last 6 characters of MAC address, printed on back of the reader or the base station
12  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   13Latest image Context based helpConnection status/Signal strengthBattery level indicator Start the Setup ToolConnect the reader to the Setup Tool to congure it with the type of symbologies it will decode as well as other parameters, such as the type of trigger it will use and the format of the results it will generate.Alternatively, congure your reader by scanning the appropriate reader conguration code from the Reader Conguration Codes document, available through the Windows Start menu.Trigger buttonRead historyQuick SetupCongure your reader in a few basic stepsConnect to ReaderEstablish a connection to the readerResults DisplayView resultsLight and Imager Settings/UltraLight SettingsChoose a trigger type and other acquisition parametersSystem SettingsCongure visual and audio feedback, trigger and output actions
Use the Edit menu for standard Cut, Copy and Paste operations. Use the View menu to view reader information (serial number, rmware version, and so on) and to enable and disable various elements of the Setup Tool, and the Tasks menu to switch between various Setup Tool options. Use the System menu to manage the current settings on the reader and to upgrade the features it currently supports: 14  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   15System MenuSave Settings Save the current parameters to non-volatile memory, which allows the reader to restore these settings each time you reboot it.Reset Conguration Reset all conguration parameters in RAM (volatile memory) to the default settings except for communication settings.Update Firmware Update the reader software.Upload Feature Key Unlock additional features available in the reader software if you have the right key.Use the Help menu to display Setup Tool version information. Use the Setup Tool Menu BarEach reader can store its current set of runtime parameters to a conguration (.cfg) le, which contains information such as the enabled symbologies and how any output data should be formatted. The same conguration le can be loaded onto multiple readers, as the le does not contain identication information such as the IP address or device name of the reader used to create it.A reader can also generate a Cognex device conguration (.cdc) le, which stores the set of runtime parameters plus any identication data, such as the name of the device, its IP address, subnet mask, and so on. Cognex recommends generating a device conguration le for each reader to allow you to restore a reader to its operating state with minimal effort. Use the File menu of the Setup Tool to manage .cfg and .cdc les: File MenuOpen Conguration Open a saved .cfg conguration le. Save Conguration Create a .cfg conguration le of current runtime parameters. Print Conguration Code Generate a programming codes sheet representing your reader’s conguration.Restore Device Load a saved device conguration .cdc le, with run-time parameters plus device-specic information for a particular DataMan 8000. Backup Device Create a device conguration .cdc le for a specic reader. Save Image Save the latest acquired image with .jpg le format.
Troubleshooting an Ethernet ConnectionWARNINGDisconnect DataMan from power before inserting/removing communication modules.2.  With a 2 mm Allen Wrench, tighten the screws so that the slide-in is rmly locked.3.  Insert the plug and slide the cable lock up to the reader and twist the cable lock in place.Use the DM8000-ECABLE-05 (5 meters) or the DM8000-ECABLE-30 (30 meters).  You also need a Power Over Ethernet Adapter (CPS-AC-POE1A-xx).location of the two screws16  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   17If your reader does not appear in the Setup Tool’s list of network devices, you may need to adjust your network settings.  First check your Ethernet connection and click Refresh in the Setup Tool. Next, scan the Enable DHCP code below (which you can also nd in the DataMan Reader Conguration Codes document available from the Windows Start menu). This might allow the reader to acquire a suitable IP address from a DHCP server on your subnet. If the reader still does not appear, you can use either the Add Device or Force Network Settings options in the Setup Tool. If you know the IP address of the reader, use the Add Device option. If you do not know the IP address, use the Force Network Settings options. Either method should allow the DataMan 8000 reader to appear in the list of Network devices so that you can connect to it through the Setup Tool and your Ethernet connection. If none of the above helps, reset your reader to factory defaults by scanning the Reser Scanner to Factory Defaults code below.Enable DHCP Reset Scanner to Factory DefaultsConnecting a DataMan 8000 through Ethernet1.  Connect the Ethernet slide-in (DMCM-ENETM-00) to your DataMan 8000.
1Observe the following electrical requirements:WARNINGFor proper RS-232 operation, do not apply any voltage to pin 9.WARNINGDisconnect DataMan from power before inserting/removing communication modules.Use the DM8000-RS232-02 cable (2.5 meters) or the DM8000-RS232-05 cable (5 meters). For power supply, use the DataMan 8000 Power Supply (DM100-PWR-000).Power on the RS-232 cable can be supplied by either the DC Power Plug or Pin 1 of the D-SUB. DO NOT use both in parallel.18  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   195 GND9 Reserved4 N/C8RTS3 RxD7 CTS2 TxD6 N/C1 VCC PWRVCCGND1.  6VDC power supply (DM100-PWR-000), a 5.5mm x 2.1mm DC Power Plug2. VCC = +4.75V up to +6.0V for 2.5 m cable    VCC = +5.5V up to +6.0V for 5.0 m cable2Connecting a DataMan 8000 through RS-2322.  With a 2 mm Allen Wrench, tighten the screws so that the slide-in is rmly locked.3.  Insert the plug and slide the cable lock up to the reader and twist the cable lock in place.1.  Connect the serial slide-in (DMCM-SERIALM-00) to your DataMan 8000.location of the two screws
20  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   21Keyboard Emulation without KeyboardKeyboard Emulation with Keyboard1. Connect the PS/2 keyboard adapter to your unpowered PC.2. Connect your PS/2 keyboard to the PS/2 keyboard adapter, and start up your PC.3.  Connect your reader to an RS-232 cable and power up your reader.4. Scan the PS/2 Keyboard Emulation Disable Conguration Code (from the Reader Conguration Codes document, available through the Windows Start menu). 5. Connect the RS-232 cable to the PS/2 keyboard adapter.6. Start reading codes.You can change your reader’s conguration by switching back to the serial interface and connecting to the Setup Tool.1.   Scan the PS/2 Keyboard Emulation Enable Conguration Code (from the Reader Conguration Codes document, available though the Windows Start menu.) 2.  Power down your PC and unplug your device from power.3.  Connect the PS/2 keyboard adapter to your PC.4.  Connect your reader’s serial cable to the PS/2 keyboard adapter and plug in your device to power. Wait until the device boots up.5.  Power up your PC and start reading codes.You can change your device’s conguration by scanning the appropriate Conguration Codes.
  OR  OR22  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   23Keyboard Emulation with Wireless Reader without Keyboard1.  With your wireless reader, scan the Base Station PS/2 Keyboard Emulation Enable Conguration Code (from the Reader Conguration Codes document, available though the Windows Start menu.) 2.  Disconnect your base station’s serial cable from your PC.3.  Power down your PC and unplug your device from power.4.  Connect your base station’s serial cable to the PS/2 keyboard    adapter and plug in your device to power.5.  Connect the PS/2 keyboard adapter to your PC.6.  Power up your PC and start reading codes.You can change your device’s conguration by scanning the appropriate Conguration Codes.Keyboard Emulation with Wireless Reader using Keyboard1. Connect the PS/2 keyboard adapter to your unpowered PC. 2. Connect your PS/2 keyboard to the PS/2 keyboard adapter. 3. Start up your PC.4. Power up your base station.5.  With your wireless reader, scan the Base Station PS/2 Keyboard Emulation Disable Conguration Code (from the Reader Conguration Codes document, available through the Windows Start menu). 6. Connect the base station to an RS-232 cable, and plug it in to the PS/2 keyboard adapter.7. Start reading codes.You can change your device’s conguration by switching back to the serial interface and connecting to the Setup Tool.
24  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   25Using your Device through USBIf you connect your reader with the coiled USB cable, you must use your device in USB 1.1 mode (which is the default mode). With a straight USB cable, you can use your device in both modes.Change the USB Connection in the Setup Tool’s Communication Settings pane’s Serial tab, or scan the appropriate code from the DataMan Conguration Codes document.You can also switch the USB mode (CDC or HID) of both the reader and the base station with a pair of RP codes. Perform the following steps:1.  Disconnect from the Setup Tool if you are connected.2. Scan the “USB Keyboard” code from the DataMan Conguration Codes document.3. Start scanning codes with your corded reader.1.  Disconnect from the Setup Tool if you are connected.2. Scan the “Enable USB Keyboard for the base station” code from the DataMan Conguration Codes document.3. Start scanning codes with your wireless reader.Connecting a DataMan 8000 through USBWARNINGDisconnect DataMan from power before inserting/removing communication modules.2.  With a 2 mm Allen Wrench, tighten the screws so that the slide-in is rmly locked.3.  Insert the plug and slide the cable lock up to the reader and twist the cable lock in place.1.  Connect the serial slide-in (DMCM-SERIALM-00) to your DataMan 8000.Use the DM8000-USB-00 cable (2.5 meters) or the DM8000-USBC-02 cable (2.5 meters). For DataMan 8500, use an external power supply: DataMan 8000 Power Supply (DM100-PWR-000).location of the two screws
26  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   27Connecting to a Wireless DataMan 8000 through a Base Station2.  With a 2 mm Allen Wrench, tighten the screws so that the slide-in is rmly locked.4.  Insert the plug and twist it in place.1.  Connect the wireless slide-in (DMCM-WLESSM-00) to your DataMan 8000.5. Power up the base station using either a 24V power supply, or a Class 3 Power Over Ethernet adapter. 6. Connect your base station to your PC using either serial, USB or Ethernet communication.Ethernet connectionRS-232 connectionUSB connection3.  Insert the battery.WARNINGRemove battery from your DataMan before inserting/removing the communication module.Powerlocation of the two screws
28  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   297. When the base station is powered up, place your reader into the base station. They become automatically paired. The base station’s status indicator becomes green. When the wireless reader is removed from the base, a wireless connection is established. The status indicator of both the base station and the reader become blue and you can hear a beep. Blue lights indicate the reader and base have successfully paired and are communicating.8. Connect to your base station or to the wireless reader. You have the possible connection options:Base Station Connection TypeConnect to Reader in the Setup Tool Connection ChannelsRS-232 Base Station appears: COM port(Wireless reader does not appear) terminal programUSB Base Station appears: COM port 1Wireless reader appears: COM port 2  terminal programSetup ToolEthernet Base station appears: Network device 1Wireless reader appears: Network device 2 terminal programSetup Tool9. Lift your reader up from the base station and start reading codes. NOTES•  When the reader is on the base, communication is established by means of cradle contacts. Wireless communication is disabled.•  Congure wireless communication settings by connecting to the base station. In order for the changed settings to be synchronized between the DataMan 8000 wireless reader and the base station, place your reader in the base station after your changes are saved. To assign a static IP address to the base station or the reader when communicating via Ethernet, connect to the base station in the Setup Tool. The base station, however, auto-assigns the IP address to the reader when they become paired.•  When you connect with the base station to a terminal program, your wireless reader sends decode results to the terminal, but you cannot send commands to the reader.•  If you want to unpair your reader from the base station, you can either click Unassign in the Setup Tool’s Communication Settings pane’s Wireless tab (when you are connected either with the reader or the base station), or scan the “Unassign Reader” reader conguration code.•  If you place the wrong reader (that is, a reader that is not associated with the base station) into the base station, the base station status indicator ashes red and a long beep is sounded. Wireless Connections (continued)
30  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   31Base Station Routing CapabilitiesThe base station is visible as connected through either RS-232, USB or Ethernet, but it routes data through the wireless interface to the reader.WirelessRS-232/USBreaderbase stationPCNETWORKEthernetWireless Reader: Buffering DataWhen you are within the wireless range of the base station, your wireless reader sends decoded data to your PC through the base station, just as if you used a tethered reader. You can also see the decoded images in the Setup Tool, if it is running and connected to the reader.When you leave the wireless range, however, you lose connection to your PC, but you can still keep reading codes. The decoded data is saved in the buffer of the reader. This buffered data appears on your PC again when you come back within the wireless range, but ONLY IF you were connected to a terminal program when you left the wireless range. Buffered read results on the reader are not displayed in the Setup Tool; they are only transmitted over an existing keyboard emulation, RS-232 Serial or TCP/IP Telnet connection. NOTE that the images acquired by the reader when it is out of wireless range are never saved, and can not be retrieved.Open a connection with the reader in a terminal program so that you gain the buffered data when wireless connection is established again. See the following table for connection options according to communication type:
32  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   33status indicator beeps twice: your reader is ofine while decoding symbolsstatus indicator blinks magenta: your reader is ofinewhen the reader leaves the wireless range, the base station’s signal stops being blueblinking blue status indicator: wireless connection is alive when the buffer is full, the reader beeps and the status indicator becomes whiteWhen the buffer is full, no more codes are read. The reader does not discard the oldest read. Base Station Con-nection Type How to ConnectRS-232 Connect to the COM port of the base station.USB Connect to the COM port of the wireless reader.Ethernet Connect to the terminal program using the IP address of the reader. To nd out the IP address, go to the Setup Tool’s Con-nect to Reader pane and hover your mouse over the reader. The IP address appears.PS/2 Keyboard or USB Keyboard Open the text editor or your program of choice to use keyboard emulation. When you return to the wireless range, keyboard emulation continues starting with the buffered data.While you are still within the wireless range, the reader occasionally blinks blue to indicate that the wireless connection is established.When the reader is ofine, good reads are indicated with 2 short beeps and the selected good read status indicator color (green by deafult).When you leave the wireless range, you can still keep reading codes. The reader going ofine is indicated by a long beep and the status indicator ashes magenta.Wireless Reader: Buffering Data (Continued)
34  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   35Condition Status Indicator: Reader Status Indicator: Base Station SoundsReader in wire-less range of base stationWhen the reader is awake, blinking blue indicates wireless connection with base.When the reader is ofine, no indicator. Pull the trigger to wake it up and it will blink blue.Good read: green, single beep (default)No read: red, no beep (default)Reader out of the base station and reader is awake: steady blue.Reader out of the base station and reader is ofine: steady red.Paired reader in the base station: steady green.Base station is receiving data or images from reader: ashing blue.Good read: 1 beep (default)No read: no beep (default)Reader out of wireless range of base stationOfine: When the reader wakes up out of the wireless range, there is no indicator.Good read: green (default)No read: red (default)Reader ofine: steady red.Long beep when you leave the wireless range.Good read: 2 beepsNo read: no beepReader out of wireless range, buffer is fullGood read: green and then whiteNo read: red (default)Reader ofine: steady red Good read: long beepNo read: no beepWireless Reader: Chargingblinking red status indicator indicates low batteryWhen you are reading codes with your wireless reader, blinking red status indicators will indicate low battery. As the battery discharges, the blink frequency increases.You can also check the status of the battery in the Setup Tool.Summary of Wireless Buffering Indicators
36  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   37Place the reader on the base station for charging.Paired Reader ChargingCondition Status Indicator: Reader Status Indicator: Base StationBattery low ashing red indicators •  steady blue, indicating wireless connection•  ashing blue, indicating data transferReader is charging in the base stationsteady red indicators •  steady green indicator•  ashing green, indicating data transferReader is fully charged in the base stationsteady green indicators •  steady green indicator•  ashing green, indicating data transferRefer to the following table for a summary of indicators regarding charging.Wireless Reader: Charging (Continued)Paired Reader Fully Charged
38  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   39Make sure the triangle aligns with the circle when the cover is locked.4. Put the end cap back on and twist it.3. Put the replacement battery into the slot. The battery has a small triangle on one of its side. Make sure you insert the battery triangle end rst.2. Hold the reader in an upright position and the battery will slide out of the handle. NOTE that you may need to shake the reader slightly.To change batteries, perform the following steps:Wireless Reader: Changing Batteries1. Twist the reader’s end cap, and take it off.The battery should not be disposed of along with municipal waste. Use the appropriate separate take-back systems for battery disposal.
40  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   41When you are charging the auxilliary battery, the base station’s spare battery status indicator displays either charging in progress (red) or fully charged (green).Field of View and Reading DistancesThere is a range of reading distances available for different code sizes and focus positions. Select a focus position that allows you to read the desired code sizes at the desired working distance.•  If your application has a consistent reading range, set the focus range to a limited depth of eld with no steps (for example, set it to 20) or with limited steps (for example, set it to 2 steps between 0 and 30). This way you can achieve fast performance.•  If your application has a variety of code types and sizes, set the focus range to a wider depth of eld with increased number of steps (for example, set it to 6 steps between 0 and 200). This way you can get better coverage.For a map of the eld of view and reading distances, see pages 42-43.5. Place the battery in the spare battery charger in the direction of the small triangle of the battery.Wireless Reader: Changing Batteries (Cont.)
42  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   43Map of Field of View and Reading Distances1D2D312 mm (12.2 in)100mmin0032003006912400 500 60015 18 21154 mm (6.06 in)33 mm (1.29 in)396 mm (15.5 in)  (2.9 in)010 mil 210 mm (8.2 in)020 mil 374 mm (14.7 in)00018 mil 500 mm (19.6 in)13 mil 409 mm  (16.1 in)7 mil 215 mm (8.4 in)05 mil 75 mm0mm in100100200200663324COGNEX
Industrial ProtocolsThe DataMan 8000 corded readers support the following industrial protocols:•  EtherNet/IP™•  PROFINET•  MC Protocol•  Modbus TCPThere are three ways to enable or disable Industrial Protocols. Using either method, a reboot is required for the changes to come into effect.•  Enable the protocols using the Industrial Protocols pane of the Setup Tool (under Communication Settings).•  Scan the appropriate Reader Conguration codes (see Reader Conguration Codes available through the Windows Start menu).•  Send the appropriate DMCC (see Command Reference available through the Windows Start menu).For more information on using the industrial protocols, read the DataMan Communications and Programming Guide available through the Windows Start menu.Select the industrial protocol tools and sample programs when installing the Setup Tool.44  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   45Trigger TypesThe DataMan 8000 trigger mode determines when the reader attempts to read a code. Use the Setup Tool, or the appropriate reader conguration codes, to change trigger types. The following trigger types are supported:•  Presentation: The laser aimer is always on. When motion is detected in front of the reader, the reader will turn on and scan for a symbol. The reader relies on an internal timing mechanism to acquire images.•  Manual (default): Begins acquiring images when you press the trigger button on the reader, and continues acquiring images until a symbol is found and decoded or you release the button.
46  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   47Weight 326 gOperating Temperature 0ºC — 40ºC (32ºF — 104ºF)Storage Temperature -40ºC — 60ºC (-40ºF — 140ºF)Maximum Humidity 95% (non-condensing)Codes Data MatrixTM; QR Code and microQR Code; UPC/EAN/JAN; Codabar, Interleaved 2 of 5, Code 39, Code 128, and Code 93, Pharma, Postal, RSS/CS, PDF 417, MicroPDF 417Power SupplyRequirements •  DataMan 8100 with USB (USB BUS powered or external      2.5 W maximum LPS or NEC class 2 power supply): +5V         - +6V DC•  DataMan 8500 with USB (external 2.5 W maximum LPS or NEC class 2 power supply is required): +5V - +6V DC         DataMan 8100/8500 with RS-232 (external 5.0W maximum LPS or NEC class 2 power supply): +4.75V - +6.0V DC (2.5 m RS-232 cable), +5.5V - +6.0V DC (5.0 m RS-232 cable)    DataMan 8100/8500 with Ethernet (Class 2 PoE supply): 6.0W maximumBattery life for wireless reader (typical use case) 2900 triggers can be operated within a 10 hour working shiftWireless protocol 802.11 b/g, 2.4 GHz, User Selectable channels 1-11DataMan 8000 Specications  DataMan Base Station Specications Weight 328 gOperating Temperature 0ºC — 40ºC (32ºF — 104ºF)Storage Temperature -40ºC — 60ºC (-40ºF — 140ºF)Maximum Humidity 95% (non-condensing)Power SupplyRequirements 24V -+ 10%, 13 W maximum LPS or NEC class 2 power supply, or PoE class 3
48  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   49Laser InformationLASER LIGHT, DO NOT STARE INTO BEAM: CLASS 2 LASER PRODUCTFAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE SERIOUS INJURY•  CAUTION: Use of controls or adjustments or performance of procedures other than those specied herein may result in hazardous radiation exposure.  •  Do not attempt to service or repair this product -- return it to Cognex for service.  •  Do not permit anyone other than Cognex Corporation to service, repair, or adjust this product. •  Do not attempt to open or modify this device except as described in this document.•  Do not direct or reect laser light toward people or reective objects. •  Do not operate this device if it is damaged or if the covers or seals are missing or damaged. This Laser Product is designated as Class 2 during all procedures of operation.Wavelength 650 nmLaser Power for classication < 1 mWBeam Diameter < 3mm at apertureDivergence < 5 mradFor assistance contact Cognex Corporation at http://support.cognex.comThe DataMan 8000 series device meets or exceeds the requirements of all ap-plicable standards organizations for safe operation. However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency guidelines that follow. Please read these guidelines carefully before using your device.The following specications apply to the DataMan 8000 corded readers:Regulator  SpecicationUSA FCC Part 15B, Class AFCC Part 15.247FDA/CDRH Laser Notice No 50Canada ICES-003European Community EN55022, Class AEN55024EN60950EN60825-1Australia C-TICK, AS/NZS CISPR 22 / EN 55022 for Class A EquipmentJapan J55022, Class AThe following specications apply to the DataMan 8000 wireless readers:Agency Compliance Statements: DataMan 8000 Series ReadersRegulator  SpecicationUSA FCC Part 15B, Class AFCC Part 15.247FDA/CDRH Laser Notice No 50Canada ICES-003RSS 210
50  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   51Regulator  SpecicationEuropean Community EN301 489-1 / -17EN300 328-2EN60950EN60825-1Australia C-TICKJapan ARIB STD-T66FCC Class A Compliance StatementThis equipment has been tested and found to comply with the limits for a ClassA digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not in-stalled and used in accordance with the instruction manual, may cause harmful interfer-ence to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interfer-ence at his own expense.This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1)  this device may not cause harmful interference, and (2)  this device must accept any interference received, including interference that may cause undesired operation. Changes or modications made to this equipment not expressly approved by Cognex may void the FCC authorization to operate this equipment.Radiofrequency radiation exposure information:For body worn operation, this device has been tested and meets the FCC RF exposure guidelines when worn in hand or close to the body. Use of any accessory may not ensure compliance with FCC RF exposure guidelines.Canadian ComplianceThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Japanese ComplianceThese devices have been granted a designation number by the Ministry of Internal Affairs and Communications according to the Ordinance concerning the Technical Regulations Conformity Certication etc. of Specied Radio Equipment(特定無線設備の技術基準適合証明等に関する規則).Article 2 clause 1 item 19Approval n°: 202WW11139331These devices should not be modied (otherwise the granted designation number will become invalid).C-Tick Statement  N13060Conforms to AS/NZS CISPR 22/ EN 55022 for Class A Equipment.European Compliance   This equipment complies with the essential requirements of EU Directives 1999/5/EC, 2004/108/EC and 2006/95/EC, as applicable. Declarations are available from your local representative. Agency Compliance Statements: DataMan 8000 Series Readers (Continued)
52  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   53Agency Compliance Statements: DataMan 8000 Series Readers (Continued)Където е приложимо, оборудването е съобразено с основните изисквания наЕвропейските директиви 1999/5/ЕС, 2004/108/ЕС и 2006/95/ЕС. Декларации са налични от местния представител. Toto zařízení splňuje základní požadavky směrnic EU 1999/5/ES, 2004/108/ES a 2006/95/ES, vždy dle konkrétního způsobu použití. Příslušná prohlášení jsou k dispozici u vašeho lokálního distributora. Dette udstyr overholder de væsentlige krav i EU-direktiv 1999/5/EF, 2004/108/EF og 2006/95/EF, som er relevant. Erklæringerne kan fås hos din lokale repræsentant. Tämä laitteisto täyttää seuraavat EU Direktiivien olennaiset vaatimukset 1999/5/EY, 2004/108/EY ja 2006/95/EY, soveltuen. Vaatimusten-mukaisuusvakuutukset ovat saata-villa paikalliselta edustajalta. Dit produkt voldoet aan de voorschriften van de richtlijnen van de EG Raad (1999/5/EC, 2004/108/EC en 2006/95/EC), indien van toepassing. Declaraties zijn beschikbaar bij uw locale vertegenwoordiger. Cet appareil est conforme aux exigences essentielles des Directives  de l’Union Europée-nne 1999/5/CE, 2004/108/CE et/ou 2006/95/CE. Veuillez consulter votre représentant local pour les déclarations applicables.                                                               Ezen készülék technikai jellemzői megfelelnek a vonatkozó 1999/5/ EC, 2004/108/EC és 2006/95/EC EU rendeletekben foglalt követelményeknek. A megfelelőségi dokumentáció a gyártó helyi partnereinél áll az Ön rendelkezésére. Questo prodotto,ove applicabile, risponde alle direttive Europee 1999/5/EC, 2004/108/EC e 2006/95/EC. Dichiarazioni sono disponibili presso il vostro rappresentante locale. Ten sprzęt jest zgodny z ogólnymi wymaganiami Dyrektyw UE nr 1999/5/EC, 2004/108/EC i 2006/95/EC, na ile znajdują zastosow-anie. Oświadczenia są dostępne u lokalnych przedstawicieli. Acest echipament este in conformitate cu cerintele esentiale ale Directivelor EU 1999/5/EC, 2004/108/EC si 2006/95/EC. Certi-catele sunt disponibile la reprezentanta lo-cala. Toto zariadenie spĺňa základné požiadavky smerníc EÚ 1999/5/ES,2004/108/ES a 2006/95/ES, vždy podľa konkrétneho spôsobu použitia. Príslušné vyhlásenia sú k dispozícii u vášho lokálneho dis-tributora. Das Gerät erfüllt die wesentlichen Anforderungen der EU-Direktiven 1999/5/EC, 2004/108/EC und 2006/95/EC, soweit anwendbar. Eine entsprechende Bescheinigung kann bei Ihrem zuständigen Vertriebspartner angefordert werden. Ta oprema je skladna in izpolnjuje nujne zahteve direktiv EU 1999/5/ES, 2004/108/ES in 2006/95/ES. Deklaracije so na voljo pri vašemkrajevnem predstavniku. Αυτός ο εξοπλισμός συμμορφώνεται με τις βασικές απαιτήσεις των εφαρμοσμένων οδηγιών 1999/5/EC, 2004/108/EC kai 2006/95/ECτης Ευρωπαικής Ένωσης. Οι επίσημες δηλώσεις είναι διαθέσιμες από τον τοπικό σας αντιπρόσωπο. Dan l-apparat huwa konformi mar-regolamenti stipulati mid-Direttivi Ewropej 1999/5/EC, 2004/108/EC u 2006/95/EC skond kif inhu likabbli. Kopji ta’ dawn id-dikjarazjonijiet huma aċċessibbli mingħand ir-rappreżentant locali tiegħek. Este equipo cumple com las condiçãos vigorantes de la EU diretivas 1999/5/EC, 2004/108/EC e 2006/95/EC, com é pertinente. Las normativas estão disponível com su representado local. Este equipo cumple con los requerimientos esenciales de las direc-tivas de la EU 1999/5/EC, 2004/108/EC y 2006/95/EC, si es aplica-ble. Dichas declaraciones están en poder de sus representanteslocales. Ši iranga atitinka esminius ES direktyvu 1999/5/EC, 2004/108/EC ir 2006/95/EC reikalavimus. Deklaracijas galima gauti iš Jusu vietinio atstovo. Šis iekartas atbilst ES direktivu 1999/5/EC, 2004/108/EC un 2006/95/EC prasi-bam. Deklaracijas ir pieejamas regionalajasparstavniecibas. See seadmed vastavad olulistele nõuetele ELi direktiivide 1999/5/EC, 2004/108/EC ja 2006/95/EC, mida kohaldatakse. Deklarat-sioonid on saadaval Teie kohaliku esindaja. Laser Safety Statement Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.This device has been tested in accordance with IEC60825-1 2nd ed., and has been certied to be under the limits of a Class 2 Laser device.
54  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   55 UL and cUL Statement  UL and cUL listed: UL60950-1 1st ed. and CSA C22.2 No.60950-1 1st ed.For European Union UsersCognex complies with Directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment (WEEE).This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment, if not properly disposed. In order to avoid the dissemination of those substances in our environment and to di-minish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way.The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take-back systems for product disposal.If you need more information on the collection, reuse, and recycling systems, please con-tact your local or regional waste administration.You may also contact your supplier for more information on the environmental perfor-mance of this product.Agency Compliance Statements: DataMan 8000 Series ReadersThe DataMan Base Station meets or exceeds the requirements of all applicable standards organizations for safe operation. However, as with any electrical equip-ment, the best way to ensure safe operation is to operate them according to the agency guidelines that follow. Please read these guidelines carefully before using your device.Regulator  SpecicationUSA FCC Part 15B, Class AFCC Part 15.247FDA/CDRH Laser Notice No 50Canada ICES-003RSS 210European Community EN301 489-1 / -17EN300 328-2EN60950Australia C-TICK, AS/NZS CISPR 22 / EN 55022 for Class A EquipmentJapan J55022, Class AARIB STD-T66Agency Compliance Statements: DataMan  Base StationFCC Class A Compliance Statement for the DataMan Base StationThis equipment has been tested and found to comply with the limits for a ClassA digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance with the instructionmanual, may cause harmful interference to radio communications. Operation of
56  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   57this equipment in a residential area is likely to cause harmful interference in which case theuser will be required to correct the interference at his own expense.This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1)  this device may not cause harmful interference, and (2)  this device must accept any interference received, including interference that may cause undesired operation. Changes or modications made to this equipment not expressly approved by Cognex may void the FCC authorization to operate this equipment.Canadian ComplianceThis Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Japanese ComplianceThese devices have been granted a designation number by the Ministry of Internal Affairs and Communications according to the Ordinance concerning the Technical Regulations Conformity Certication etc. of Specied Radio Equipment(特定無線設備の技術基準適合証明等に関する規則).Article 2 clause 1 item 19Approval n°: 202WW11139332These devices should not be modied (otherwise the granted designation number will become invalid).Agency Compliance Statements: DataMan Base Station (Continued)C-Tick Statement  N13060Conforms to AS/NZS CISPR 22/ EN 55022 for Class A Equipment.European Compliance   This equipment complies with the essential requirements of EU Directives 1999/5/EC, 2004/108/EC and 2006/95/EC, as applicable. Declarations are available from your local representative. Където е приложимо, оборудването е съобразено с основните изисквания наЕвропейските директиви 1999/5/ЕС, 2004/108/ЕС и 2006/95/ЕС. Декларации са налични от местния представител. Toto zařízení splňuje základní požadavky směrnic EU 1999/5/ES, 2004/108/ES a 2006/95/ES, vždy dle konkrétního způsobu použití. Příslušná prohlášení jsou k dispozici u vašeho lokálního distributora. Dette udstyr overholder de væsentlige krav i EU-direktiv 1999/5/EF, 2004/108/EF og 2006/95/EF, som er relevant. Erklæringerne kan fås hos din lokale repræsent-ant. Tämä laitteisto täyttää seuraavat EU Direktiivien olennaiset vaatimukset 1999/5/EY, 2004/108/EY ja 2006/95/EY, soveltuen. Vaatimusten-mukaisuusvakuutukset ovat saatavilla paikalliselta edustajalta. Dit produkt voldoet aan de voorschriften van de richtlijnen van de EG Raad (1999/5/EC, 2004/108/EC en 2006/95/EC), indien van toepassing. Declaraties zijn beschikbaar bij uw locale vertegenwoordiger. Cet appareil est conforme aux exigences essentielles des Directives  de l’Union Européenne 1999/5/CE, 2004/108/CE et/ou 2006/95/CE. Veuillez consulter votre
58  DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide   59représentant local pour les déclarations applicables.                                                               Ezen készülék technikai jellemzői megfelelnek a vonatkozó 1999/5/ EC, 2004/108/EC és 2006/95/EC EU rendeletekben foglalt követelményeknek. A megfelelőségi dokumentáció a gyártó helyi partnereinél áll az Ön rendelkezésére. Questo prodotto,ove applicabile, risponde alle direttive Europee 1999/5/EC, 2004/108/EC e 2006/95/EC. Dichiarazioni sono disponibili presso il vostro rappresentante locale. Ten sprzęt jest zgodny z ogólnymi wymaganiami Dyrektyw UE nr 1999/5/EC, 2004/108/EC i 2006/95/EC, na ile znajdują zastosow-anie. Oświadczenia są dostępne u lokalnych przedstawicieli. Acest echipament este in conformitate cu cerintele esentiale ale Directivelor EU 1999/5/EC, 2004/108/EC si 2006/95/EC. Certi-catele sunt disponibile la reprezentanta lo-cala. Toto zariadenie spĺňa základné požiadavky smerníc EÚ 1999/5/ES,2004/108/ES a 2006/95/ES, vždy podľa konkrétneho spôsobu použitia. Príslušné vyhlásenia sú k dispozícii u vášho lokálneho dis-tributora. Das Gerät erfüllt die wesentlichen Anforderungen der EU-Direktiven 1999/5/EC, 2004/108/EC und 2006/95/EC, soweit anwendbar. Eine entsprechende Bescheinigung kann bei Ihrem zuständigen Vertriebspartner angefordert werden. Ta oprema je skladna in izpolnjuje nujne zahteve direktiv EU 1999/5/ES, 2004/108/ES in 2006/95/ES. Deklaracije so na voljo pri vašemkrajevnem predstavniku. Αυτός ο εξοπλισμός συμμορφώνεται με τις βασικές απαιτήσεις των εφαρμοσμένων οδηγιών 1999/5/EC, 2004/108/EC kai 2006/95/ECτης Ευρωπαικής Ένωσης. Οι επίσημες δηλώσεις είναι διαθέσιμες από τον τοπικό σας αντιπρόσωπο. Dan l-apparat huwa konformi mar-regolamenti stipulati mid-Direttivi Ewropej 1999/5/EC, 2004/108/EC u 2006/95/EC skond kif inhu likabbli. Kopji ta’ dawn id-dikjarazjonijiet huma aċċessibbli mingħand ir-rappreżentant locali tiegħek. Este equipo cumple com las condiçãos vigorantes de la EU diretivas 1999/5/EC, 2004/108/EC e 2006/95/EC, com é pertinente. Las normativas estão disponível com su representado local. Este equipo cumple con los requerimientos esenciales de las direc-tivas de la EU 1999/5/EC, 2004/108/EC y 2006/95/EC, si es aplica-ble. Dichas declaraciones están en poder de sus representanteslocales. Ši iranga atitinka esminius ES direktyvu 1999/5/EC, 2004/108/EC ir 2006/95/EC reikalavi-mus. Deklaracijas galima gauti iš Jusu vietinio atstovo. Agency Compliance Statements: DataMan Base Station (Continued)Šis iekartas atbilst ES direktivu 1999/5/EC, 2004/108/EC un 2006/95/EC prasi-bam. Deklaracijas ir pieejamas regionalajasparstavniecibas. See seadmed vastavad olulistele nõuetele ELi direktiivide 1999/5/EC, 2004/108/EC ja 2006/95/EC, mida kohaldatakse. Deklarat-sioonid on saadaval Teie kohaliku esindaja. For European Union UsersCognex complies with Directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment (WEEE).This product has required the extraction and use of natural resources for its pro-duction. It may contain hazardous substances that could impact health and the environment, if not properly disposed. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way.The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take-back systems for product disposal.If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste administration.You may also contact your supplier for more information on the environmental performance of this product.
P/N 590-7135Copyright © 2011 Cognex Corporation All Rights Reserved. This document may not be copied in whole or in part, nor transferred to any other media or language, without the written permission of Cognex Corporation. The hardware and portions of the software described in this document may be covered by one or more of the U.S. patents listed on the Cognex web site http://www.cognex.com/patents.asp. Other U.S. and foreign patents are pending. Cognex, the Cognex logo, UltraLight and DataMan are trade-marks, or registered trademarks, of Cognex Corporation. Reader Control CodesReset Scanner to Factory Defaults  USB KeyboardUSB SerialReboot ScannerUS English German French Spanish JapaneseKeyboard LanguageEnable DHCP

Navigation menu