Catalogue 1. Technical Specification ............................................................................................................................................ 61.1 Feature ............................................................................................................................................................................ 61.2 Technical ......................................................................................................................................................................... 61.2.1 Main function ...................................................................................................................................................... 61.2.2 Technical parameter ......................................................................................................................................... 71.2.3 Operational environment ............................................................................................................................. 72. Sketch map .................................................................................................................................................................... 82.1 Physical construction ............................................................................................................................................... 82.2 Weight ............................................................................................................................................................................. 82.3 Illustration of LED display ..................................................................................................................................... 82.4 Interfaces ....................................................................................................................................................................... 92.4.1 Power supply, communication and I/O interface ............................................................................. 92.4.2 I/O Interface definition ................................................................................................................................ 102.4.3 Feeding line(optional) .................................................................................................................................. 122.4.4 Network connection diagram ................................................................................................................... 123. Installation ................................................................................................................................................................... 143.1 Notes ............................................................................................................................................................................. 143.2 Installation conditions .......................................................................................................................................... 143.3 Device connection .................................................................................................................................................. 143.3.1 Power on ............................................................................................................................................................. 143.3.2 Antenna connection ...................................................................................................................................... 153.3.3 PC connection ................................................................................................................................................... 153.4 Device installation ................................................................................................................................................... 153.5 Acceptance ................................................................................................................................................................. 15
3.5.1 Acceptance of structure ............................................................................................................................... 153.5.2 Performance acceptance ............................................................................................................................. 164. Software operating ................................................................................................................................................. 174.1 Demo software ......................................................................................................................................................... 174.2 Application environment ..................................................................................................................................... 174.3 Software version ...................................................................................................................................................... 174.4 Installation .................................................................................................................................................................. 174.5 Operation .................................................................................................................................................................... 184.5.1 Device connection .......................................................................................................................................... 184.5.2 Data display area ............................................................................................................................................. 224.5.3 Write data ........................................................................................................................................................... 264.5.4 TCP server / client mode ............................................................................................................................. 294.5.5 Antenna configuration ................................................................................................................................. 304.5.6 Base band parameter configuration ..................................................................................................... 314.5.7 Antenna port power setting ...................................................................................................................... 324.5.8 Clock setting ...................................................................................................................................................... 334.5.9 Frequency Hopping ....................................................................................................................................... 344.5.10 Label filtering ................................................................................................................................................. 354.5.11 Buffer and breakpoint resume ............................................................................................................... 364.5.12 Auto idle set up ............................................................................................................................................. 384.5.13 GPI/O configuration .................................................................................................................................... 394.5.14 Others ................................................................................................................................................................. 414.5.15 Tools .................................................................................................................................................................... 425. Common failures ...................................................................................................................................................... 455.1 Daily maintenance .................................................................................................................................................. 455.2 Common failure analysis and solution ......................................................................................................... 45
6. Package .......................................................................................................................................................................... 476.1 Package ........................................................................................................................................................................ 476.2 Accessories ................................................................................................................................................................. 476.3 Storage environment ............................................................................................................................................. 487. After-sale service ...................................................................................................................................................... 52
 6  1. Technical Specification 1.1 Feature CL7206C is a high performance eight antenna port fixed UHF RFID  reader  and  writer; support  ISO18000-6C/6B  protocols.  The  work  frequency  includes  China  standard  dual frequency  920MHz  ~  925MHz  and  840MHz~845MHz,  FCC  902MHz  ~  928MHz  and  ETSI 865MHz ~ 868MHz.   Output  power  from  0  ~  33dBm  optional,  with  long  identification  distance,  fast  reading speed,  high accurate rate, strong anti-interference ability,  good  protection  performance  and easy installation 1.2 Technical 1.2.1 Main function   Protocol: support ISO18000-6C/6B standard   Built-in LINUX operating system   Multiple communication port (Ethernet, RS232, RS485, USB),   Support tag data filtering   Support RSSI: the intensity of the perceived signal   Adjustable RF output power   Optional working mode: constant frequency / frequency hopping     Supports antenna detection function   Supports online and remote upgrade   I/O interface: 4 port opt coupler input, 4 port relay output and Weigand output
 7  1.2.2 Technical parameter   Working frequency: ETSI 865MHz~868MHz   Output power (port): 33dBm + 1dB (MAX)   Power adjustment: 1 dB step-by-step   Reading distance: 0 ~8meters (depending on tags, antennas and environment)   Channel bandwidth: <200 KHz   RS232 serial communication rate: 115200bps (default), 19200 bps, 9600bps   RS485 interface communication rate: 115200bps (default), 19200 bps, 9600bps   Wiegand output support wiegand 66, 34 & 26 types.   Power supply: 30V ~ 10V (power capacity is not less than 60W)   Power adapter: AC input 100V ~ 50Hz, 240V ~ 60Hz   DC output: 24V/2.5A  High protection grade: IP53 1.2.3 Operational environment   Working environment: -20℃~+30℃   Relative Humidity: 5%RH~90%RH(+25℃)
 8  2. Sketch map 2.1 Physical construction  Image 2-1 Structure diagram of CL7206C Size: 256mm*147.6mm*43.47mm 2.2 Weight Main body: 1.14kg(accessories excluded) 2.3 Illustration of LED display  Image2-2    Sketch map of reader’s LED indicator LED indicator panel describe as below Form 2-1:                       Form 2-1    LED indicator description LED Mark  Mark NO.  Status description
 9  NO.   ANT1  Antenna 1 indicator  Indicates antenna 1 is working ANT2  Antenna 2 indicator  Indicates antenna 2 is working ANT3  Antenna 3 indicator  Indicates antenna 3 is working ANT4  Antenna 4 indicator  Indicates antenna 4 is working POWER  Power indicator Keep bright indicates power supply working normally   2.4 Interfaces 2.4.1 Power supply, communication and I/O interface    Image 2-3 Sketch map of reader’s power supply, communication and I/O interface,   Details are shown in form 2-2 Form 2-2   Reader’s power supply, communication and I/O interface, Interface ID  Interface Name  Detail description POWER  Power supply  DC,10~30V, power capacity no less than 60W. RJ45  Ethernet interface 10/100M  Ethernet  interface,  the  reader  control  and communication interface. USB DEVICE  USB device port  PC  and  other  PC  connected,  the  reader  control  and
 10  communication interface. USB HOST  USB host port For  external  U  disk,  wireless  LAN  and  other  expansion devices. RS-232  RS-232 serial port  Serial communication interface with control reader. Other  I/O interface  See detailed definition 2.4.2.  2.4.2 I/O Interface definition  Image 2-4 Sketch map of I/O control interface I/O control signal define as follow form 2-3                                 Form 2-3 I/O control signal definitions PIN Identification PIN Description R1  Relay  Output  #  1;  DC_MAX:  30V,  2A;  AC_MAX:  125V,  0.3A;  logic '0' indicates the open, a logic '1' means close, the default is open. L1  Relay  output  #  1,  DC_MAX:  30V,  2A;  AC_MAX:  125V,  0.3A;  logic '0' indicates the open, a logic '1' means close, the default is open R2  Relay  output  #  2,  DC_MAX:  30V,  2A;  AC_MAX:  125V,  0.3A;  logic '0' indicates the open, a logic '1' means close, the default is open.
 11  L2  Relay  output  #  2,  DC_MAX:  30V,  2A;  AC_MAX:  125V,  0.3A;  logic '0' indicates the open, a logic '1' means close, the default is open. R3  Relay  #  3  output,  DC_MAX:  30V,  2A;  AC_MAX:  125V,  0.3A;  logic '0' indicates the open, a logic '1' means close, the default is open. L3  Relay  #  3  output,  DC_MAX:  30V,  2A;  AC_MAX:  125V,  0.3A;  logic '0' indicates the open, a logic '1' means close, the default is open. R4  Relay  output  #  4,  DC_MAX:  30V,  2A;  AC_MAX:  125V,  0.3A;  logic '0' indicates the open, a logic '1' means close, the default is open. L4  Relay  output  #  4,  DC_MAX:  30V,  2A;  AC_MAX:  125V,  0.3A;  logic '0' indicates the open, a logic '1' means close, the default is open. GND  ground GND  ground IN1 # 1 optocoupler input, DC, 0 ~ 12V, higher than 9V is high, less than 8V is low level. IN2 # 2 optocoupler input, DC, 0 ~ 12V, higher than 9V is high, less than 8V is low level. IN3  # 3 optocoupler input, DC, 0 ~ 12V, higher than 9V is high, less than 8V is low level. IN4 # 4 optocoupler input, DC, 0 ~ 12V, higher than 9V is high, less than 8V is low level. IN_GND Optocoupler  input,  the  reader  optocoupler  external  input  signal ground. WG0  Wiegand Data 0 signal, the default state is high.
 12  WG1  Wiegand Data 1 signal, the default state is high. GND  Ground 485-A  RS485 A-side signal 485-B  RS485 B-side signal 2.4.3 Feeding line(optional)   Image 2-6 schematic diagram of feeder line RF cable TNC(Reverse polarity, internal thread, inner pin) connector  connect  with reader antenna TNC connector, RF cable SMA connector connect with  external  circular polarization  antennas  SMA  connector,  cable  maximum  length  is  5m,  impedance  50Ω, insertion  loss  is  less  than  2dB,  or  you  also  can  choose  a  high  performance  cable, appropriate increase in length, insertion loss is less than 2dB. Note: If Ultra long RF cable or the cable joint is not contacted well, may cause performance deterioration on the read and write because of the emission signal and the received echo signal’s attenuation.    2.4.4 Network connection diagram Network interface used for long-distance high-speed connection (less than 80 m), can be connected with  the  switcher or router through the  network  cable, or  directly connected
 13  with the PC network interface, as shown in figure 2-7:   Image 2-7 Network application connection diagram
 14  3. Installation 3.1 Notes To ensure the normal and stable operation of the device and your personal property and safety, please carefully read the following notes before install CL7206C reader and writer: 1. Firstly, check whether the power socket is connected to the ground, and to see whether the local power supply voltage is in accordance with the applicable voltage range of the reader; 2. Check the device and the external connection if is closely connected; 3. Pay attention to the type selection and the length limit of the cable and the serial line:  Network cable connects directly, no longer than 80 meters  Serial line connects directly, no longer than 10 meters 4. When installing several readers, the antenna position and the antenna spacing should be appropriate to avoid interference with each other. 3.2 Installation conditions Before installing the reader, please carefully check if the product is in good condition, the accessories are complete or not, if there is any damage, please contact the supplier. 3.3 Device connection 3.3.1 Power on   Insert  the power  cord  into the  AC  power supply  socket and  plug another end into the power connector of the device and tighten. Turn on and wait about 20 seconds, the system initialization process is completed and is standby state.
 15  3.3.2 Antenna connection The device built with four TNC coaxial cable connector for connecting an external antenna, select  low  consumption  RF  cable,  connectors  should  be  tightened (Ensure to be waterproof when install outdoors); The reader antenna angle or corner to adjust to the best position through the actual test according to the specific application,. 3.3.3 PC connection The device provides special adapter cable, including interface of network, serial and power; RS232  interface  is  for  short  distance  communication  (less  than  10m), through the DB9 connector and the PC serial port connection to realize the communication of PC and the device. RJ45 network port used for long distance communication (less than 80m), connect PC with extend cable. 3.4 Device installation The reading and writing range of the reader depends on the onsite application, the tilt angle of the antenna is adjusted to achieve the best reading and writing performance. 3.5 Acceptance Mainly from two aspects of acceptance criteria: structure and performance. 3.5.1 Acceptance of structure    Check below details:   Whether reader is fixed firmly, without loose;   Whether the cable connected firmly ;
 16    Whether the screws are tighten 3.5.2 Performance acceptance   Whether the reader is working properly;   Whether the read and write range is reasonable.
 17  4. Software operating 4.1 Demo software The demo software mainly carries on system control, communication mode selection, parameter setting and searching, read and write tags and data presentation and so on. Before using the demon software, please check if the connection of the reader hardware is completed, mainly ensure the following tips: 1, If the reader and computer serial port (network or RS485) is connected correctly 2, If the antenna ports have been connected to the antenna (ANT, ANT1 2, ANT 3, ANT totally four ports) 3, If the reader and writer start up (hear "drop" buzzer sound). 4.2 Application environment  The software environment Windows  2000  Service  Pack  3、  Windows  Server  2003、Windows  XP  Service  Pack  2、Windows 7 system  The hardware environment P4/1.7GHz above PC, 512M or more memory, 40GB hard drive 4.3 Software version    V2.0.2 4.4 Installation 1. Copy the software to the PC, open the software installation package, double click “setup” application, and follow the installation guide. 2. Click the next step, and select the installation path, click next, and the software will begin to
 18  install. 3. Click the "Install", and software installation progress takes about 1mins. 4. After the progress of the software is finished, click the "finish"  button  to  complete  the installation. 4.5 Operation 4.5.1 Device connection All functions can be operated only after successful connection. 4.5.1.1 Serial communication connection Double click the icon   to start the Demo software, the main interface of the toolbar icons are gray means reader is not connected, in the ‘connecting reader’ option list select communication  mode  ‘serial  connection’,  ‘connection  parameters’  select  ‘COM?’ (choose  PC  serial  number),  communication  baud  rate  select  115200  (default),  click “OK“  button,  as  shown  in  image 4-6.
 19   Image 4-6 Serial communication connection If  the  connection  is  successful,  all  the  icons  in  the  toolbar  are  illuminated,  as  shown  in image 4-7, means the serial communication connection is successful.
 20   Imag4-7 serial port communication connect successful  4.5.1.2 Network port communication connection Network  port  used  for  long  distance  connection  (within  80  m),  connect  to  the  router through cable and switcher, router, or connected with the PC network port directly. Select the communication  mode  "TCP  connection"  in  the  "connect  reader"  option  list,  "connect parameter"  input  reader  IP  (default  192.168.1.116),  enter  the  communication  port  number (default 9090), and click OK button, as shown in image 4-8
 21  Image 4-8 Network port communication connection The device has been written IP address 192.168.1.116 as default. If you forget or need to modify, using serial connection "connection" after connect successfully, then you can found the current  IP  address  through  select  “settings” >  "senior"  >  “configuration”,  set  up  the  IP address in “Network port settings” when “configuration” dialog pops up. See image 4-9 Note:  The IP address of the reader can’t be repeated. Use the Ping command  to  test whether the network is connected on PC.  image 4-9 reader configuration 4.5.1.3 RS485 communication connection Select the communication mode in the "connect to the reader" option  "485 connection (serial port)", "connect parameter" select "COM?" (select PC serial number), communication rate select "115200", enter the RS485 address, then click OK, as shown in image 4-10.
 22                            Image 4-10 485 communication connection RS485 address defaults to 1 RS485 address range 1~255 Note: Click the button            after changing the configuration 4.5.1.4 USB communication connection Select the communication mode "serial port" in the "connect reader"  option  list,  "connect  parameter"  select  "COM?"  (the  USB serial number detected by PC), the communication rate is selected "115200" (the default value), and click OK button, as shown in image 4-11.                            Image 4-11 USB communication connection 4.5.2 Data display area Click the button  ,the data display area will show as image 4-12
 23   Image 4-12 data display area parameter meanings Type: label type: 6C, 6B two types EPC: EPC data of tags, can be read and write. TID: the TID data of the label, the only logo, read only User Data: user data area, can be read and write. Reserve Data: reserved area data, store the password data, etc. Total Count: total number of tags ANT1: the reading times of NO.1 antenna ANT2: the reading times of NO.2 antenna ANT3: the reading times of NO.3 antenna ANT4: the reading times of NO.4 antenna RSSI:Signal Intensity 4.5.2.1 Read EPC
 24  Click the button , the data display area will display the current read EPC data EPC display as hexadecimal character string, use the word as length unit (1 word = 2 bytes = 4 hexadecimal character)   If you want to read the EPC data of the custom length, please refer to chapter 4.5.2.3 custom read 4.5.2.2 Read TID Click the button , the data display area will display the current read EPC and TID data TID data display as hexadecimal character string, use the word as length unit (1 word = 2 bytes = 4 hexadecimal character). TID length, the default is 6 words. If you want to read the TID data of the custom length, please refer to chapter 4.5.2.3 custom read 4.5.2.3 Custom read Click the button , pop-up dialog box, as shown in Image 4-13 Select "6C tag configuration" Matching read, you can matching read through known EPC data or TID data of tags. Read TID, select to read the tag TID data, the read mode default as "adaptation", use the word as length unit. Read the user area, select to read the tag user area data, use the word as the starting address and read length unit Read  the  reserved  area,  select  to  read  the  tag  retains  data,  use  the  word  as  the  starting address and read length unit
 25    Image 4-13 6C Tag custom configurations Select the 6B tag configuration, and pop up dialog box as shown in image 4-14 Can choose to read TID data or user data Can matching read TID data. Tip: Customer who not familiar with the label agreement, please ignore this feature
 26   Image    4-14 6B Tag custom configurations 4.5.2.4 Stop read Click button    stop all read and write operations. 4.5.3 Write data 4.5.3.1 Write EPC data Click button and pop up dialog box as shown in image 4-15:
 27   Image 4-15 write EPC data Select a label data (contains TID information) has been read, fill in the EPC data (16 hex string), click "OK". 4.5.3.2 Write user data Click button    and pop up dialog box as shown in image 4-16:
 28   Image 4-16 write user data Select a label data (contains TID information)has been read, fill in the user data (16 hex string), click "OK". 4.5.3.3 Custom tag action Click button    and pop up dialog box as shown in image 4-17:
 29   Image 4-17 Custom tag action       1. Select a tag data that has been read; 2. Click the "custom operation" button; 3. Take detailed action to write / lock / destroy tag according to the reader protocol 4.5.4 TCP server / client mode Select configuration on the main demo interface > "read and write configuration >" TCP server / client mode ", pop-up dialog box, as shown in Image 4-18:
 30   Image 4-18 Mode setting When the reader is configured as a "server" mode, the connection is initiated by PC; when the reader set as a "client" mode, it will connect to the PC side automatically. 4.5.5 Antenna configuration Select" configuration" on the DEMO main interface-- > "senior"-- > "reader configuration ", then pop-up dialog box, as shown in image 4-19.
 31   Image 4-19 Antenna enable configuration Select  all  antenna  enable configuration,  click the  "configuration",  pop  up  dialog  box, click "OK"  means  configure  succeeds.  If  the  antenna  enable  is  not  selected,  when  select  the corresponding reader on the DEMO main interface, will pop up dialogue box as shown in image 4-20.    Image 4-20 Antenna selection 4.5.6 Base band parameter configuration Select "configuration" on the DEMO main interface --> "senior" --> "reader", then pop-up dialog box, as shown in image 4-21.
 32   Image 4-21 Base band parameter configuration Changing the base band parameter configuration can change the actual effect of the read and write (can be reasonably configured according to the application scenarios, but it needs to be operated under the guidance of our engineers). EPC base band rate provides five options: Tair=25us, FM0, LHF=40KHz, dense reading mode; Tair=25us, Miller4, LHF=300KHz; fast reading mode; 255/OUTO. Session four choices: 0; 1; 2; 3. Q values provide sixteen options: 0/ single label; 1; 2; 3; 4/ multi label; 5; 6; 7; 8; 9; 10; 14; 11; 12; 13; 15. There  are  three  options  for  searching  tags:  one  side  search;  inventory  only  with  Flag  B; double search. 4.5.7 Antenna port power setting Select  "configuration"  on  the  DEMO  main  interface  -->  "senior"  -->  "reader",  pop-up
 33  dialog box, as shown in image 4-22.                                Image 4-22 Antenna port power setting Select the corresponding antenna port (external antenna connected), select the appropriate power values from the power list, click Configure, pop up the configuration of the success of the dialog box, click OK to complete power configuration. 4.5.8 Clock setting Select "configuration" on the DEMO main interface --> "senior" --> "reader configuration", then pop-up dialog box, as shown in image 4-23. The current time of the reader can be check in the area of the “reader time”. If you need to modify the reader time, modify the “reader time” then click “configuration” button, pop-up dialog box then click OK.
 34   Image 4-23 Clock display setting 4.5.9 Frequency Hopping Click “configuration” on the main interface > RFID configuration  >  "hopping management", pop-up frequency hopping management dialog box, as shown in image 4-24  Imag 4-24 Frequency Hopping management Select "CMII, 920-925MHz" (see Image 4-25) in the "working band" drop-down list, click the "Settings", select single frequency points from the left frequency list box(see Image 4-24) then
 35  click the " " button, right into the list box, and then click the "configuration" to confirm; If you want to select the full band frequency hopping just click    all the frequency points will show on the right side of the list box, click the "configuration" to confirm. If you click  , all frequency points on the right side of the list box will be cleared.                             Image 4-25 Frequency Band selection Note: The purpose of setting up the "automatic" is to avoid the interference of the external signal and select the fast frequency hopping. The default configuration for general application is automatically (as shown red mark dropdown list in image 4-24). 4.5.10 Label filtering Select  "configuration"  on  the  main  interface  >  "RFID  configuration"  >  "label  filter",  then pop-up dialog box, as shown in image 4-26:
 36                                       Image 4-26 label filtering Filtering time: indicates that the same label content within a specified period of time within a read card instruction is only uploaded once, 0~65535, and time units: 10ms. RSSI threshold: When label RSSI value small than the threshold value, the label data will not be uploaded and discarded.    4.5.11 Buffer and breakpoint resume For make sure the reader ‘s complete collection of rfid tags’ data, CL7206C support tag data-caching mechanism and breakpoint resume, in case that the tag’s data loss because of the communication interrupted or PC application error exit, the tag data by caching mechanism could be saved without power.   Data caching mechanism mode’s start: Main manu’s setting  Advanced  Reader setting  Breakpoint, choose “ON” then it will validate the function of tag’s caching mechanism. As image 4-27 shows.
 37   Image 4-27 tag filter After the validate the breakpoint resume function, the PC will reply each data of tags uploading, reader will automatically save the tag’s data which are not uploaded. PC could operate the saved data through setting  Obtain saved data or setting  clear saved data. As below image 4-28.
 38   Image 4-28 tag buffer data operation As under the breakpoint resume mode, PC will confirm to each tag data from reader, under mass quantity of   tag data will reduce the communication efficiency, increase the system load, we suggest: When start the breakpoint upload functions, according to your application, can set up suitable “tag filter parameter” “filter time” to reduce the extra data uploading.   4.5.12 Auto idle set up Select  "configuration"  on  the  main  interface >  "RFID  configuration" > "auto idle ", then pop-up dialog box, as shown in image 4-29:
 39                Image 4-29 Auto idle configuration Auto idle mode means when the reader continuous reading tags, all using antenna didn’t identify the tags for three times continuously ,then the reader automatically enter a period of idle state to save power consumption, the reader re-enter the card reader automatically after idle time. 4.5.13 GPI/O configuration GPI/O control is to provide the query and set up the I/O port state, control the function of the I/O device. GPI configuration Select  “configuration  “on  the  main  interface  -->  "GPI/O  configuration"  -->  “GPI configuration "then pop-up dialog box, as shown in image 4-30:
 40                                  Imag 4-30 GPI configuration  Check: check the various port trigger parameters  Configuration: select the port need to set, click button to execute the settings after modify  Trigger start condition: select the mode from the drop-down list  Trigger execution instruction: select the mode from the drop-down list  Trigger stop condition: select the mode from the drop-down list  Description: when the start condition is satisfied, the reader will perform the configuration of the reader/ writer command. GPO configuration Select  “configuration”  on  the  main  interface  >  "GPI/O  configuration"  >  "  GPO configuration "then pop-up dialog box, as shown in image 4-3:
 41  Image 4-3 GPO configuration CL7206C reader only supports four GPO outputs, that is "1" “2”, “3”, “4”.   Select the high / low level, click this configuration to execute settings after modify. 4.5.14 Others Wigand configuration Select “configuration” on the main interface --> "GPI/O configuration" --> “Wigand "then pop-up dialog box, as shown in image 4-30:                   Image    4-30 Weigand configuration In the Weigand parameter settings area, set up the “communication switch” for the "open" state, and select the corresponding "communication format" and "transmission data content", click on the "configuration" to determine. Weigand  port  Parameter  configuration:  includes  “Weigand  26,  “Weigand  34"  and
 42  “Weigand 66"models. Weigand 26: TID or EPC data reported from the end of the Weigand port is valid for 3 bytes. Weigand 34: TID or EPC data reported from the end of the Weigand port is valid for 4 bytes. Weigand 66: TID data reported from the end of the Weigand port is valid for 8 bytes. Restore factory settings Select  “configuration”  on  the  main  interface  > “restore factory settings” then pop-up dialog box, as shown in image 4-31:  Image    4-31 restore factory settings When connected to the reader in any form, click OK button, and all settings of the reader will be restored to the factory setting. 4.5.15 Tools Data export Select "tools" on the main interface > "data export" > "form (*. XLS), in the pop-up dialog box, as shown in image 4-32, select the required export file save path.
 43   Image 4-32 Data export Read the tag data to support data export, export format can be.csv (comma file) and.Xls (Excel). Software upgrade The reader support for online upgrade, software upgrades support the baseband software upgrade  (the  underlying  software)  and  application  software  upgrades  (system  software applications).  Select  "tools"  on  the  main  interface  >  "software upgrade" > "software", the pop-up dialog box, as shown in image 4-33:
 44   Image 4-33 Application software upgrade To find the Bin upgrade file path in the upgrade file drop-down list, click   the upgrade progress bar shows 100% that means the application software upgrade successfully, pop-up upgrade prompted success dialog box, click OK to restart the reader, as shown in image 4-34.   Image 4-34 Software upgrade successfully The  process  of  the  application  of  the  base  band  software  is  the  same  as  that  of  the application software.
45 5. Common failures5.1 Daily maintenance The routine maintenance of CL7206C usage: ☆To check whether the tightening of RF connector☆To check if the screw fixed reader and antenna is loose☆To check whether the RF cable joints appear outsourcing breaking the shielding layer☆To check if the reader power line connection is reliable5.2 Common failure analysis and solution Power supply system failures: Check whether the power adapter is normal, and the AC supply voltage is between 100V ~ 240V. The panel indicator light failed when power on: Check whether the communication is normal; please contact customer service if it’s not normal. The serial port unable to connect: Check if the serial cable is not connected or connected unstable. Check if the serial port connect baud rate of the reader is correct Check if the selected COM port is right. The network port cannot connect: Factory set the default IP address: 192.168.1.116 when CL7206C reader device ex-factory, ensure  the  IP  address  of  the  PC  and  reader  in  the  same  network  segment,  such  as "192.168.1.XXX" then you can connect to the reader, if you forget the IP address of the device,
46 you can reset the reader’s IP address through the serial port. The reader can't read the tag Check if the setting of antenna number is correct Check if the label is damaged Check if the label is placed in the reader's valid reading and writing range. Check if the electromagnetic interference between the reader and the other device. For the problem users cannot solve, please contact customer service.
 47  6. Package  6.1 Package                              Imag6-1 Carton box size Carton box size: 290X290X76MM 6.2 Accessories In order to facilitate the storage and transportation in near future, the packing box and the packing material should be kept properly after unpack. Besides of the device in the box, accessories equipped with the reader are also included in, please check the product packing list to confirm whether the product  and  accessories  are complete, if any discrepancies or damage, please contact with the after-sale service in time. The specific list of accessories as shown in table 6-1
48 Table 6-1 Package list 6.3 Storage environment   CL7206C fixed reader should be stored in below conditions: NO.  Name  Material Code  Qty  Unit  Remark 1  CL7206C Four-port fixed reader  ——————  1  set  Included 2  Power adapter 24V/2.5A  20109000000324 1  pcs  Included 3  AC power cord  20350000000195 1  unit  Included 4  Network cable  20350000000188 1  unit  Included 5  RS232 blackcable  20351000000478 1  pcs  Included 6  USB cable  20351000000036 1  pcs  Included 7  9dBi circularly polarized antenna  20351000000035 4  pcs  Optional 8  Feeder line SMA-K--TNC-J reversed polarity 20351000000814 4  pcs  Optional 9  Mounting screws M4*28  W01-104028-100 4  pcs  Included 10  Warranty card  20420000001651 1  pcs  Included 11  Certificate of approval  20420000001650 1  pcs  Included 12  CD  N10-010000-002 1  pcs  Optional
49 ☆ Environment temperature:-40℃~+85℃☆ Relative humidity:5% RH~95%RH
50 DECLARATION OF CONFORMITY Hereby,Shenzhen Clou IOT Technologies Co.,Ltd. declares that this Integrated Fixed Reader product in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the Declaration of Conformity can be found an Website: http://www.clouiotech.com/ Testing standards: EN 60950-1:2006 + A11:2009 + A1:2010+A12:2011+A2:2013 EN 62311:2008 EN 301 489-1 V1.9.2(2011-09) ETSI EN 301 489-3 V1.6.1(2013-08) EN 302 208-1 V2.1.1: 2015-02 EN 302 208-2 V2.1.1: 2015-02 Manufacturer's Name: Shenzhen Clou IOT Technologies Co.,Ltd. RFID Reader   Trade Mark: N/A Model number: CL7206C This device was tested for typical body‐worn operations. To comply with RF exposure requirements, a minimum separation distance of 50cm must be maintained between the user’s body and the handset, including the antenna. Third‐party belt‐clips, holsters, and similar accessories used by this device should not contain any metallic components. Body‐worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna. This device in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. All essential radio test suites have been carried out. 1. CAUTION : RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE
51 OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS 2. The device complies with RF specifications when the device used at 50cm form your bodyCare for the environment! Must not be discarded with household waste! This product contains electrical or electronic components that should be recycled. Leave the product for recycling at the designated station, e.g. the local authority's recycling station. 3. Adapter shall be installed near the equipment and shall be easily accessible.4. The plug considered as disconnect device of adapterFCC WARNINGThis device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Any changes or modifications not expressly approved by the party responsible for compliancecould void the user's authority to operate the equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-- Reorient or relocate the receiving antenna.-- Increase the separation between the equipment and receiver.-- Connect the equipment into an outlet on a circuit differentfrom that to which the receiver is connected.-- Consult the dealer or an experienced radio/TV technician for help.To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.FCC ID:  2AKAGCLOUIOTCL7206C
52 7. After-sale serviceLetter to Customers Since our aim is to continuously improve our products for better user experience, we may modify  the  product  characteristics,  composition  and  design  of  circuits  without  given notifications. Thus the real product may be not in accordance with this manual. Generally, we will provide timely amendments to this manual. If it’s not provided timely, please consult our service department. Shenzhen Clou IOT Technologies Co., Ltd. Tel of Sales Dept: 0755-36901039 Tel of Customer Service Dept: 0755-36901039 Email: RFIDoverseas@szclou.comGuarantee card of Shenzhen Electrical Technology Co.,Ltd
53 Product Name  Model No. Product Code  Level Description of troubles User’s name  Postcode Contact person  Contact no. Address  of  factory:  Block  3  of  CLOU  Electronics  Industrial  Park,  Baolong  Industrial  City, Longgang District ,Shenzhen, Guangdong, China (Interchange of Baolong road and Qingfeng Road) Post code: 518057                          Customer service centre: +86-755-36901057 Warranty  Description: In order to offer users better service, our company provide warranty card with each device, please keep it to enjoy the service. 1, Products can replace free under conditions within one month after sale, in the precondition of normal operation without repairing. 2, Free maintenance won’t be given under the following circumstance: ①The damage of the terminal caused by high voltage of the power grid.② The damage caused by misuse or operated improperly.③The damage caused by excessive vibration when user delivering.3, The software of this product can be upgraded freely, users can be training in our company for free. 4, Will be charge appropriately if the user don’t have a warranty card. 5, Users will need to fill out the warranty card for repair service, and sent back to CLOU.