Cisco Systems IXMLPWA900 Cisco LoRaWAN Interface Module User Manual

Cisco Systems Inc Cisco LoRaWAN Interface Module

Contents

Users Manual_rev

1Cisco Systems, Inc. www.cisco.com Getting Started andProduct Document of Compliance for theCisco LoRaWAN Interface ModuleFirst Published: 2016-09-20Last Updated: 2016-10-1078-100921-01C0Cisco Information, page 2Introduction, page 2Unpacking the Device, page 2Equipment That You Supply, page 3Related Documentation, page 3Installation Warning and Caution Statements, page 4Becoming Familiar With the Device, page 5Power, page 8Pole/Wall Mounting, page 9Grounding the Device, page 15Regulatory Compliance and Safety Information, page 15For the complete installation procedure, please refer to the Cisco LoRaWAN Interface Module Hardware Installation Guide on Cisco.com:http://www.cisco.com/c/en/us/support/routers/interface-module-lorawan/products-installation-guides-list.htmlImportant!Read All the Safety Information Before Installing the Hardware.
2Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface Module Cisco InformationCisco InformationIntroductionThe purpose of this document is to provide the installer the necessary information for installing the Cisco LoRaWAN Interface Module. The documentation is on-line, and subject to change. Make sure that you are downloading or viewing on-line the latest version before beginning an installation:http://www.cisco.com/c/en/us/support/routers/interface-module-lorawan/products-installation-guides-list.htmlUnpacking the DeviceFollow these steps to unpack the box:1. Open the shipping container and carefully remove the contents. 2. Return all packing materials to the shipping container and save it.3. Ensure that all items listed in the “Package Contents” section on page 2 are included in the shipment. Check each item for damage. If any item is damaged or missing, notify your authorized Cisco sales representative. Package ContentsEach Cisco LoRaWAN Interface Module package contains the following items:One Cisco LoRaWAN Interface Module (IXM-LPWA-800-16-K9 or IXM-LPWA-900-16-K9)This document (Part Number 78-100921-01)Optional EquipmentDepending on what you ordered, the following optional equipment may be part of your shipment:Wall/pole mount kit (AIR-ACC1530-PMK1=)DC-IN power adapter jack plug (PLG-PWRJCK=)Grounding lugLoRa Antenna—Omni-directional antenna (ANT-LPWA-DB-O-N=)—Antennas lightning arrestor (ACC-LA-H-NM-NF=)—10-ft low-loss cable assembly with N type connector (AIR-CAB010LL-N=)GPS Antenna—Outdoor GPS antenna with integrated 15-ft cable (ANT-GPS-OUT-TNC=)Table 1 Cisco Company Name and Address DetailsCompany Name Cisco AddressCisco Systems, Inc. 170 West Tasman Drive, San Jose, CA 95134-1706, United States.
3  Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface ModuleEquipment That You Supply—Outdoor GPS antenna lightning arrestor (ACC-LA-G-TM-TF=)Equipment That You SupplyESD-preventive cord and wrist strap.Crimping tool (such as Thomas & Bett part number WT2000, ERG-2001, or equivalent).6 AWG (13.3 mm2) copper ground wireWire-stripping tools for stripping 6 AWG (13.3 mm2) wireA number-2 Phillips screwdriverRelated DocumentationTo access resources or to display the latest Cisco LoRaWAN Interface Module documentation on-line, go to this URL:www.cisco.com/go/lorawanmoduleThis portal has all of the information you need to get to know your device, install and configure it, as well as access software. Look at the right side of the page under Support. You will see the following categories as well as other important information:All support information for Cisco LoRaWAN Interface Module: Provides the most requested resources and a list of all of the models in the series.Software Downloads, Release and General Information: Links to the Software Download site, Compatibility Information, Licensing Information, and Product Release notes.Install and Upgrade: This is your starting point for Installing the Router. look under the Install and Upgrade Guide section for this model,Configure: These links provide configuration information. Look first under the Configuration Guide section for this model.Other important and helpful links to Cisco information are here:Cisco.com: www.cisco.comWarranty Information: www.cisco-warrantyfinder.comCisco Information Packet, consisting of Cisco Limited Warranty, Disclaimer of Warranty, End User License Agreement, and United States Federal Communications Commission Notice: www.cisco.com/en/US/docs/general/warranty/English/SL3DEN__.htmlCisco Marketplace: marketplace.cisco.comCisco Product Documentation: www.cisco.com/go/techdocsCisco Support: www.cisco.com/cisco/web/support/index.html
4Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface Module Installation Warning and Caution StatementsInstallation Warning and Caution StatementsWarning: IMPORTANT SAFETY INSTRUCTIONSMeans danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071Warning: Before performing any of the following procedures, ensure that power is removed from the DC circuit. Statement 1003Warning: Read the installation instructions before you connect the system to its power source. Statement 1004Warning: This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 2 A. Statement 1005Warning: This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017Warning: A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.Statement 1022Warning: This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024Warning: Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030Warning: Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040Warning: For connections outside the building where the equipment is installed, the following ports must be connected through an approved network termination unit with integral circuit protection: 10/100 Ethernet Statement 1044Warning: To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of: 131°F (55°C) Statement 1047Warning: This equipment is intended to be grounded to comply with emission and immunity requirements. Ensure that the switch functional ground lug is connected to earth ground during normal use. Statement 1064Warning: Installation of the equipment must comply with local and national electrical codes. Statement 1074Warning: Avoid using or servicing any equipment that has outdoor connections during an electrical storm. There may be a risk of electric shock from lightning. Statement 1088Caution: For the device, connect only to an NEC Class 2 power source or limited power source as defined by IEC 60950-1.Warning: This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting.Warning: The product shall be installed at a location where the radiating antenna can be kept 23 cm from nearby person in normal operation condition to meet regulatory RF exposure requirement.Warning: Use only the antennas which have been approved by the applicant. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of FCC/ISED limit and is prohibited.
5  Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface ModuleBecoming Familiar With the DeviceWarning: Please carefully select the installation position and make sure that the final output power does not exceed the limit set force in relevant rules. The violation of the rule could lead to serious federal penalty.Note: The device is suitable for use in environmental air space in accordance with section 300.22.C of the National Electrical Code and sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, C22.1. You should not install the power supply or power injector in air handling spaces.Note: Use only with listed ITE equipment.Note: The maximum ambient operating temperature range is –40 to 131°F (–40 to 55°C), plus solar load.Note: The POE source which the unit is intended to connect is IEEE 802.3 at.FCC CautionAny changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation in accordance with FCC multi-transmitter product guidelines.Industry Canada StatementThis device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Radiation Exposure StatementThis equipment complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 23 cm between the radiator and your body. Déclaration d'exposition aux radiationsCet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 23 cm de distance entre la source de rayonnement et votre corps.Becoming Familiar With the DeviceThe following illustrations show the connections of the Cisco LoRaWAN Interface Module. Before you begin the installation process, use these illustrations to familiarize yourself with the device.
6Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface Module Becoming Familiar With the DeviceFigure 1 Cisco LoRaWAN Interface Module Bottom and Right Panels1Pressure vent 4LED indicators2DC power port  5USB port3PoE-in port 6Console port and Reset button
7  Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface ModuleBecoming Familiar With the DeviceFigure 2 Cisco LoRaWAN Interface Module Top and Left PanelsAntennasThe Cisco LoRaWAN Interface Module is equipped with two N-type radio frequency (RF) connectors (antenna ports 1 and 2) on the top of the unit for LoRa antennas, and one TNC connector on the left of the unit for the GPS antenna, as shown in Figure 3 on page 8. The LoRa antennas should be connected to the chassis via an appropriate low-loss RF coax cable, for the Cisco LoRaWAN Interface Module to work properly. The LoRa antennas should be installed closely to the Cisco LoRaWAN Interface Module to reduce the signal strength loss on the feed cable as much as possible. Note: The antennas can't be directly installed on the unit without a cable.For detailed information on the antenna installation options, see the Cisco LoRaWAN Interface Module Hardware Installation Guide.Refer to the data sheet for the antenna specifications.Note: The antenna port caps must be removed before using, but the unused ports should remain capped to provide an IP67 seal. All port or antenna connection must be terminated by an IP67 rated cap or cable.FCC CautionAny changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation in accordance with FCC multi-transmitter product guidelines.Radiation Exposure StatementThis equipment complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 23 cm between the radiator and your body. 1LoRa antenna ports 2Ground lug location3GPS antenna port
8Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface Module Becoming Familiar With the DeviceDéclaration d'exposition aux radiationsCet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 23 cm de distance entre la source de rayonnement et votre corps.Figure 3 Antenna ConnectorsAntenna Mounting ConfigurationsThe selection of the antenna is determined in the configuration of the product. The antennas can be mounted on a wall, pole and/or tower mounted. The antennas must be installed at half a wavelength apart from each other.Note: The FCC limits the amount of power this device can transmit. Power transmitted is a combination of the amplification of the signal and the antenna gain. The Cisco LoRaWAN Interface Module has been designed to operate with the Cisco provided antennas.PowerNote: For detailed information on the power options available for the Cisco LoRaWAN Interface Module, see theCisco LoRaWAN Interface Module Hardware Installation Guide.Warning: Installation of the equipment must comply with local and national electrical codes. Statement 1074Warning: This equipment must be externally grounded using a customer-supplied ground wire before power is applied. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 366Warning: Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001The Cisco LoRaWAN Interface Module supports these power sources:Power-over-Ethernet (PoE+, 30W)1TNC connector for GPS antenna 2N-Type connectors for LoRa antennas
9  Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface ModulePole/Wall MountingDC power—48 VDCCaution: Do not place the power injector in an unprotected outdoor environment because water could get into the power injector and cause a short circuit and possible fire.Warning: Connect the unit only to DC power source that complies with the Safety Extra-Low Voltage (SELV) requirements in IEC 60950 based safety standards Statement 1033Ethernet (PoE+) PortsThe Cisco LoRaWAN Interface Module supports an Ethernet uplink port (PoE-In). The RJ-45 connector (with weatherproofing) links the device to the 10BASE-T or 100BASE-T network. The Ethernet cable is used to send and receive Ethernet data and to optionally supply inline 56-VDC power from the power injector.Warning: To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Statement 1023The Ethernet cable must be a shielded outdoor rated Category 5 (CAT5) or better cable. The Cisco LoRaWAN Interface Module senses the Ethernet and power signals and automatically switches internal circuitry to match the cable connections.LEDsThis section describes the LEDs for the Cisco LoRaWAN Interface Module. See Figure 1 on page 6 for the locations of LED indicators.Pole/Wall MountingNote: For more installation options and detailed installation instructions, see the Cisco LoRaWAN Interface Module Hardware Installation Guide.The Cisco LoRaWAN Interface Module can be pole or wall mounted by using the mounting kit (AIR-ACC1530-PMK1=).Table 2 LED DefinitionsLED LED Color DefinitionSystem LED (LED 1) Off Power off or under bootloader modeBlinking green Under the starting kernel (bring up phase)Solid green Normal operation stateBlinking red Failed to get IP addressRegister to IR800 failedSolid red ACT2 check failedLost connection to IR800CPU usage highTemperature highFlash usage highCover openReserved LED (LED 2) Reserved for future use. —
10Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface Module Pole/Wall MountingWarning: Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030Warning: Installation of the equipment must comply with local and national electric codes. Statement 1074When mounting a Cisco LoRaWAN Interface Module on a horizontal or vertical surface, you must ensure that the device is oriented with the LED indicators pointing down (see Figure 4 on page 10). This positioning allows LEDs to be visible to someone on the ground below the device.You must also ensure the Cisco LoRaWAN Interface Module is mounted in such a way as to ensure that all antenna ports and the console port are accessible for future use.Figure 4 LEDs Shown on the Bottom of the Cisco LoRaWAN Interface Module1Pressure vent 3PoE-in port2DC power port 4LED indicators
11  Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface ModulePole/Wall MountingWall Mounting With the Mounting KitThe mounting kit contains a mounting bracket for wall mounting or pole mounting. You can use the mounting bracket as a template to mark the positions of the mounting holes for your installation. You then install the mounting plate, and attach the Cisco LoRaWAN Interface Module when you are ready. Table 3 lists the materials you will need to provide in addition to the fixed mounting kit.Note: The mounting surface, attaching screws and optional wall anchors must be able to support a 50-lb (22.7 kg) static weight.To mount the Cisco LoRaWAN Interface Module on a vertical wall, follow these instructions:1. Use the mounting bracket as a template to mark four screw hole locations on the mounting surface. See Figure 5 on page 12 for the mounting bracket screw hole locations. Use the bracket mount holes to attach the unit to the wall.Table 3 Material Needed for Vertical Wall MountingMaterials Required In KitGround lug and screws (provided with Cisco LoRaWAN Interface Module) YesOne mount bracket YesFour M6 x 12-mm Hex-head Bolts YesCrimping tool for ground lug NoFour wall mounting screws NoFour wall anchors (specified for all material) NoDrill bit for wall anchors NoElectric drill and standard screwdriver No#6 AWG ground wire NoShielded outdoor-rated Ethernet (CAT5 or better) cable with 4.3 to 6.5 mm (0.17 to 0.25 inch) diameter (for IP67 and strength relief)NoGrounding block NoGrounding rod No10-mm box-end wrench or socket set No
12Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface Module Pole/Wall MountingFigure 5 Mounting Bracket for Wall or Pole Mounting2. Use four customer-supplied screws and optional screw-anchors to attach the mounting plate to the mounting surface.3. If necessary, use suitable screw anchors and an exterior-grade plywood backboard to mount the Cisco LoRaWAN Interface Module to stucco, cement or drywall.4. Screw an M6 x12 mm bolt into each of the four support bolt holes on the back of the Cisco LoRaWAN Interface Module. Do not screw the bolt all the way in; leave approximately a 0.13 inch (3.3 mm) space.5. Position the four bolts on the Cisco LoRaWAN Interface Module into the keyhole slots on the mounting bracket. 6. Slide the Cisco LoRaWAN Interface Module down to sit securely in the quick mount slots.7. Using a 10mm wrench, secure the Cisco LoRaWAN Interface Module to the bracket by tightening the bolts to the bracket; torque to 40 in-lbs (4.52 N-m).8. Continue with Grounding the Device, page 15. 1Quick Mount Keyhole Slots (for the Cisco LoRa Interface use)2Mounting Slots (used with the band clamps)3Bracket Mount Holes (use bolts up to 1/4" or 6 mm in diameter)
13  Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface ModulePole/Wall MountingPole Mounting With the Mounting KitThe mounting kit contains a mounting bracket for wall mounting or pole mounting. This kit can be used to install the Cisco LoRaWAN Interface Module on a pole. It supports metal, wood or fiberglass poles from 2 to 8 inches in diameter.To mount the Cisco LoRaWAN Interface Module onto a vertical pole, follow these steps:1. Select a mounting location on the pole to mount the Cisco LoRaWAN Interface Module. You can attach the Cisco LoRaWAN Interface Module to any pole with a diameter from 2 to 8 inches (5.1 to 20.1 cm).2. Determine which size of band clamp is needed based on the pole diameter. Slide the two clamps through the top and bottom set of mounting slots (see Figure 6 on page 14) and mount the bracket to the pole.3. Wrap the band clamps around the pole and slide them into the second set of top and bottom mounting slots on the bracket. Lightly tighten the clamps. Only tighten them enough to keep the bracket from sliding down the pole.4. Screw an M6 bolt into each of the four bolt holes on the back side of the Cisco LoRaWAN Interface Module. Do not screw the bolt in all the way. Leave a gap of about 1/8" (3.3mm).5. Position the four bolts on the Cisco LoRaWAN Interface Module into the bracket keyhole slots. Check to be sure that the Cisco LoRaWAN Interface Module is properly seated in the slots.(See Figure 6 on page 14)6. The Cisco LoRaWAN Interface Module should be positioned with the LEDs on the bottom to allow viewing from the ground.7. Using a 10mm wrench, tighten the four bolts that connect the Cisco LoRaWAN Interface Module to the bracket to a torque of 40 in-lbs (4.52 N-m). 8. Locate the Cisco LoRaWAN Interface Module to its final position. Tighten the band clamps with the wrench so that the Cisco LoRaWAN Interface Module does not slide on the pole. Be sure that the clamps are tight enough that the Cisco LoRaWAN Interface Module does not move.9. Continue with Grounding the Device, page 15. Table 4 Materials Needed for Vertical Pole MountingMaterials Required In KitOne mount bracket YesFour M6 x12mm hex head bolts YesTwo stainless steel band clamps (adjustable 2"–5", 51–127 mm) YesTwo stainless steel band clamps (adjustable 5"–8", 127–203 mm) Yes10 mm box-end wrench NoShielded outdoor-rated Ethernet (CAT5 or better) cable with 4.3 to 6.5 mm (0.17 to 0.25 inch) diameter (for IP67 and strength relief)NoGround lug (provided with the Cisco LoRaWAN Interface Module) YesGround block and rod NoCrimping tool for ground lug No#6 AWG ground wire No
14Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface Module Pole/Wall MountingFigure 6 Cisco LoRaWAN Interface Module and Fixed Mount Kit Installed on a Pole1Metal Band Strap 2Mounting Slots3Pole
15  Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface ModuleGrounding the DeviceGrounding the DeviceMake sure to follow any grounding requirements at your site.Warning: This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024Warning: Installation of the equipment must comply with local and national electrical codes. Statement 1074Warning: The equipment has a separate protective earthing terminal on the chassis that must be permanently connected to the earth ground to adequately ground the chassis and protect the operator from electrical hazards. Caution: Before equipment installation begins, ensure that a service personnel has attached an appropriate grounding lug to the grounding cable that you supply. Caution: Power installation must be performed with qualified electrician and followed with National Electrical Code, ANSI/NFPA 70 and Canadian Electrical Code, Part I, CSA C22.1. To connect earth ground to the unit: 1. Connect one end of the grounding cable to a proper earth ground.2. Place the grounding lug attached to the grounding cable over the protective earthing terminal.3. Secure the grounding lug to the protective earthing terminal with the washers and screws.4. Dress the grounding cable and ensure that it does not touch or block access to other components.Warning: Before the device is powered on, connect the frame of the unit to the earth.Warning: For the earthing wire, green-and-yellow insulation is required and the cross-sectional area of the conductor must be more than 0.75mm2 or 26 AWG.Warning: The product shall be installed by a qualified service person and the installation shall conform to all local codes.Regulatory Compliance and Safety InformationDeclarations of Conformity and Regulatory InformationFor the declarations of conformity and regulatory information for the Cisco LoRaWAN Interface Module, see the Cisco LoRaWAN Interface Module Hardware Installation Guide.For EMC and safety information, see the Regulatory Compliance and Safety Information at this URL:http://www.cisco.com/go/lorawanmodule
16Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface Module Regulatory Compliance and Safety InformationCompliance InformationClass A Notice for FCCModifying the equipment without Cisco’s authorization may result in the equipment no longer complying with FCC requirements for Class A digital devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct any interference to radio or television communications at your own expense.This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense.EMC Class A Notices and WarningsStatement 340—Class A Warning for CISPR22Specification DescriptionSafety IEC 60950-1EN 60950-1UL 60950-1EN 60950-22EN 50385IEC/EN 60529EMC Electromagnetic Emissions FCC 47 CFR Part 15 Class AEN 55022 Class AElectromagnetic Immunity EN 55024EN 301 489-1/-3Radio EN 300 220-2EN 300 440-2WarnungDies ist ein Produkt der Klasse A. Bei der Verwendung dieses Produkts im Haus- oder Wohnungsbereich kann es zu Funkstörungen kommen. In diesem Fall muss der Benutzer u. U. angemessene Maßnahmen ergreifen.
17  Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface ModuleRegulatory Compliance and Safety InformationChina RoHSNote: This Table is a regulatory document required for products shipped to the People’s Republic of China.Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to thisURL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnershiprelationship between Cisco and any other company. (1110R)© 2016 Cisco Systems, Inc. All rights reserved.
18Getting Started and Product Document of Compliance for the Cisco LoRaWAN Interface Module Regulatory Compliance and Safety Information