Appendix 2

Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            181 October 23, 2003    Appendix O:  RFS System Test (Cable Sweeps)   Introduction  Before installing the Base Station at a site, the RFS and the associated cables must be tested, and the results of the tests documented. This procedure applies to the full RFS sub-assembly and associated cables:  data/power cable, RF cables, and the RFS unit. All results are recorded in the RFS System Test Form P/N 40-00093-00.   Procedures – Combo & Split Chassis Base Stations   RFS Data/Power Cable (Combo and Split BTS Configurations Only)  This test will check the integrity of the data/power cable. The cable being tested consists of six twisted pairs of conductors. The conductors will be tested for continuity, opens, and shorts. Male connectors are on both ends of the cable. Each connector is wired the same. You will need to check all cables – the main cable from the RFS to the data/power cable surge protector, and the jumper cable from the data/power cable surge protector to the BTS. The pin layout is shown in Figure O1, looking at the connector face. Table O1 provides the pin layout details.  Figure O1:  Pin Layout                 A B C D E F G H J K L M
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 182                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Table O1:  Pin layout Details                  Perform the continuity test with both the Volt Ohm Meter (VOM) and the power/data cable tester. If the power/data cable tester is not available, perform the continuity test with the VOM.  Required Equipment  ?? VOM – Continuity tester ?? Jumper for shorting pins ?? RFS power/data cable tester  Continuity Test With VOM  Step 1. On one end of the cable, short a pair of conductors using a shorting device.  Step 2. Using a VOM/Digital Volt Meter (DVM) set to ohms, verify a short is present on the pair at the other end.  Step 3. Leaving one probe on one of the paired pins, contact all of the other pins with the other probe, ensuring an open connection.  Step 4. Check all 6 pairs of wires in the same manner.  Step 5. Verify continuity from the connector case to the drain wire (pin D) on each end of the cable and between each connector case. Step 6. Verify an open circuit from the connector case to each individual wire, except to the drain wire. Wire Color Wire Color Signal NameRED PAIR +12V ABLACK +12V A RTNBROWN HeaterDRAIN GND (Shield Wire)BLACK PAIR RX_EN_B-WHITE RX_EN_B+BLUE PAIR RX_EN_A+BLACK RX_EN_A-BLACK PAIR Diagbus-GREEN Diagbus+BLACK PAIR +12V B ReturnYELLOW +12V BPOWER CABLE PIN OUTABCDCircularConnector(s)JKLMEFGH
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            183 October 23, 2003  Continuity Test With Power/Data Cable Tester  Step 1. Connect one end of the power/data cable to the connector on the power/data cable tester. Step 2. Using a VOM/DVM set to ohms, check resistance to ground on the other end of the cable. Resistance is checked from the case of the connector to the individual pin. Resistance readings (+/– 10 percent ) are shown in Table O2. Table O2:  Resistance to Ground  Pin Resistance Pin Resistance A 1K ohms G 6.2K ohms B 2K ohms H 8.2K ohms E 3.3K ohms L 10K ohms F  5.1K ohms M 12K ohms  Step 3. Using a VOM/DVM set to ohms, check resistance between the pairs on the other end of the cable. Resistance should be the sum of the resistance of the two pairs, +/– 10 percent. Refer to Table O3. Table O3:  Resistance of Two Pairs  Pins Resistance Pins Resistance A & B 3K ohms G & H 14.4K ohms E & F 8.4K ohms L & M 22K ohms  Step 4. Remove the power/data cable tester from the power/data cable.   Sweep Test of RF Cables & RFS  Sweep testing of the RF cables and the RFS is performed in three separate steps.   ?? Sweep of the cables  ?? Sweep of the RFS  ?? Sweep of the cables and the RFS together  All results will be entered in the RFS System Test Form, P/N 40-00093-00. The total of the insertion loss for the cables and the RFS will be equal to the insertion loss of both parts swept together.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 184                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Equipment Required  ?? Signal Generator - Agilent 8648C, or suitable alternative, tunable to the RFS center frequency ?? Spectrum Analyzer - Agilent E4402B, or equivalent ?? Signal Generator cable and Spectrum Analyzer cable – Gender can be changed using a barrel connector ?? Male and Female barrel connectors for Signal Generator cable and Spectrum Analyzer cable connections ?? Power/data test cable ?? Navini RFS Test Box  Equipment Settings  Spectrum Analyzer: ?? Span – 5 MHz      ?? RBW – 100 KHz ?? VBW – 100 KHz ?? Sweep Time – Auto ?? Frequency (Provided in Table O4)  Signal Generator: ?? Amplitude – 0 dB ?? Frequency (Provided in Table O4)  Test Setup  When performing each type of sweep, the sweep has to be performed at certain frequency intervals (Table C5). Perform the complete test at the first frequency. Go to the next frequency and recalibrate the test setup. Perform the complete test again. Do the same for the third frequency. Refer to Figure O2.  Table O4:  Sweep Frequencies  System Sweep 1 Sweep 2 Sweep 3 2.3 GHz High band 2348.25  2352.50  2357.50 2.3 GHz Low band 2307.50  2312.50  2316.75 2.4 GHz 2400.00  2440.00  2473.50 2.5 GHz 2500.00  2548.00  2596.00 2.6 GHz 2602.00  2620.00  2641.00 2.6 GHz EFGH 2602.00  2641.00  2683.00
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            185 October 23, 2003  1.  Connect the Signal Generator cable to the Signal Generator. 2.  Connect the Spectrum Analyzer cable to the Spectrum Analyzer.  3.  Connect the other end of the cables together. Use a barrel connector if needed.  Figure O2:  Test Setup                        Test Procedure  The following procedures are for the Agilent E4402B Spectrum Analyzer. If alternative equipment is used, refer to the manufacturer’s calibration procedures. The key point is to make accurate microwave frequency power measurements.  Step 1. Turn the Signal Generator and Spectrum Analyzer on. Allow the equipment to warm up for 15 minutes for the output to stabilize. Step 2. Set the Signal Generator frequency to the desired test frequency (Table O4) of the RFS under test.  Step 3. Set the Signal Generator output amplitude to 0 dBm. Step 4. Set the center frequency of the Spectrum Analyzer to the center frequency of the RFS under test. Step 5. Set the Spectrum Analyzer to Span = 5 MHz and Resolution Bandwidth = 100 kHz. Spectrum AnalyzerSignal GeneratorBarrel Connector (if needed)Signal Generator CableSpectrum Analyzer CableSpectrum AnalyzerSignal GeneratorBarrel Connector (if needed)Signal Generator CableSpectrum Analyzer Cable
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 186                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 Step 6. Take a marker measurement on the Spectrum Analyzer by using the ‘marker to peak’ or the ‘peak search’ function. The screen on the Spectrum Analyzer should look similar to that shown in Figure O3. Figure O3:  Sweep Test Marker Measurement Example                 If the marker measurement doesn’t read 0.0 dBm, adjust the amplitude on the Signal Generator until the Spectrum Analyzer marker reads 0.0 dBm, or as close to 0.0 dBm as possible. This will remove all losses associated with the test cables. All measurement data should be recorded one digit to the right of the decimal point, for example, 31.5dB. Once the test setup is calibrated, these cables will remain in place and will be used throughout the whole test. If the test cables are removed or changed, incorrect readings will result.  RF Cable Insertion Loss  This test is performed on all RF cables that are installed in the system. This includes the eight antenna cables, the system calibration cable, and all jumper cables. Follow the procedures for either the cables on the ground or cables run up the tower.  Test Procedure For RF Cables on the Ground  Step 1. Ensure calibration of the test setup has been performed each time the test frequency is changed. Step 2. If present, remove the barrel connector from between the Signal Generator and Spectrum Analyzer cables. Step 3. Connect the cable from the Signal Generator to one end of the cable. Use a barrel connector to change the gender, if required.  Step 4. Connect the cable from the Spectrum Analyzer to the other end of the cable. Use a barrel connector to change the gender, if required.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            187 October 23, 2003 Step 5. Take a marker measurement on the Spectrum Analyzer by using the ‘marker to peak’ or the ‘peak search’ function. The screen on the Spectrum Analyzer should look similar to the one shown in Figure O4. Figure O4:  Insertion Loss (Cables on Ground) Marker Measurement Example                      Step 6. The result should be within +/– 0.5 dB of the calculated value. If the insertion loss results do not agree with the manufacturer’s data, check the connectors for proper connection to the cable, and check for kinks in the cable. If the Spectrum Analyzer has a distance to fault (DTF) function, it can be used to help troubleshoot kinks in the cable.  CAUTION! Cables with results greater than the specified limits (i.e., 2 or 3 dB high) should not be installed, as a potential hardware fault exists.  Step 7. Record the data in the RFS System Test Form under “MAIN FEEDER LOSS” or “JUMPER LOSS”. Ensure that the information is recorded under the channel number that is on the cable label. Step 8. Repeat steps 3 through 7 for all remaining cables and jumpers.  Step 9. Change the frequency to the next test frequency (refer back to the Test Setup section of these procedures). Perform steps 1 through 8 until all cables have been successfully tested at the frequencies shown in Table O4.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 188                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 Test Procedure For RF Cables Already Run Up the Tower  Step 1. Ensure calibration of the test setup has been performed each time the test frequency is changed. Step 2. If present, remove the barrel connector from between the Signal Generator and Spectrum Analyzer cables. Step 3. Have a member of the tower crew positioned on the tower, at the upper end of the cables, connect the calibration cable to antenna cable 1 with a barrel connector.  Step 4. At the lower end of the RF cables, connect the cable from the Signal Generator to the calibration cable. Use a barrel connector to change the gender, if required. Step 5. Connect the cable from the Spectrum Analyzer to antenna cable 1. Use a barrel connector to change the gender, if required. Step 6. Calculate the marker using the following formula:  (the length of BOTH the calibration cable and the antenna cable) x (loss per foot at the RFS center frequency for the type of cable used). Step 7. Take a marker measurement on the Spectrum Analyzer by using the ‘marker to peak’ or the ‘peak search’ function. The screen on the Spectrum Analyzer should look similar to the one shown in Figure O5.  Figure O5:  Insertion Loss (Cables on Tower) Marker Measurement Example                   Step 8. The result should be within +/– 0.5 dB of the calculated value. If the insertion loss results do not agree with the manufacturer’s data, check the cable connectors for proper connection to the cable, and check for kinks in the cable. If the Spectrum Analyzer has a distance to fault (DTF) function, this can be used to help troubleshoot kinks in the cable.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            189 October 23, 2003 Step 9. Divide this value in half and assign the result to the calibration cable and to the antenna cable.  Caution: Cables with results greater than the specified limits (i.e., 2 or 3 dB high) should not be installed, as a potential hardware fault exists.  Step 10. Record the data in the RFS System Test Form under “MAIN FEEDER LOSS”. Ensure that the information is recorded under the channel number that is on the cable label. Step 11. Repeat steps 3 through 10 for antenna cables 2 through 8.  Step 12. When finished, take the average of the eight values obtained for the calibration cable. Use this value for the insertion loss of the calibration cable. Step 13. Change the frequency to the next test frequency (refer back to Test Setup). Perform steps 1 through 12 until all cables have been successfully tested at the frequencies given in Table O4. Step 14. Check the value of the nine jumpers at all three frequencies, per the procedure for cables on the ground. Record the data in the RFS System Test Form under “JUMPER LOSS”. Ensure that the information is recorded under the channel number that is on the cable label.  RFS Test Box Setup Step 1. For RFS only testing, connect the power/data test cable to the data connector on the RFS and to the RFS Test Box.  - OR - For RFS and cable testing, connect the installation power/data cable to the data connector on the RFS and to the RFS Test Box.  Refer to Figure O6. Step 2. Connect the RFS Test Box power supply to the RFS Test Box. Step 3. Plug the RFS Test Box power supply into a 110 VAC outlet. Figure O6:  RFS Only Testing Setup             Power/Data cable connected to the RFSRFS Test BoxRFS Test Box power supplyPower/Data cable connected to the RFSRFS Test BoxRFS Test Box power supply
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 190                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  RFS Only Transmit Verification  Ensure that the calibration of the test setup and RFS Test Box setup for RFS Only has been performed each time the test frequency is changed. Refer to Figure O7.  Step 1. Switch the RFS Test Box to the transmit (Tx) mode. Step 2. Connect the cable from the Spectrum Analyzer to the RFS cal connector. Use a barrel connector to change the gender, if required. Step 3. Connect the cable from the Signal Generator to the RFS antenna input number 1. Use a barrel connector to change the gender, if required. Figure O7:  RFS Only Tx Verification                  Note: The position of the RFS will vary the sweep results due to reflections from the test surface.    Step 4. Take a marker measurement on the Spectrum Analyzer by using the ‘marker to peak’ or the ‘peak search’ function. The screen on the Spectrum Analyzer should look similar to the one shown in Figure O8.          Barrel connector Signal Generator cable to RFS antenna 1 connector Spectrum Analyzer cable to RFS cal connector Barrel connector Signal Generator cable to RFS antenna 1 connector Spectrum Analyzer cable to RFS cal connector
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            191 October 23, 2003  Figure O8:  RFS Only Tx Marker Measurement Example                  Step 5. The marker value should be equal to the RFS Only Tx insertion loss within +/– 2.0 dB, per the manufacturer’s data. If the insertion loss results do not agree with the manufacturer’s data, check the test setup.  Caution: An RFS with results greater than the +/– 2.0 dB limits should not be installed, as a potential hardware fault exists. Contact Navini Networks Technical Support.  Step 6. Record the data in the RFS System Test Form under “RFS TX PATH LOSS (RFS ONLY)”. Ensure that the information is recorded under the channel number of the RFS antenna that is being tested. Step 7. Repeat steps 5 and 6 for the remaining seven antenna inputs on the RFS. Step 8. Change to the next test frequency (refer back to Test Setup). Perform steps 1 through 8 until the RFS has been successfully tested at the frequencies shown in Table O4.  RFS Only Receive Verification  Step 1. Ensure calibration of the test setup and RFS Test Box setup for RFS Only has been performed each time the test frequency is changed. Step 2. Switch the RFS Test Box to the Receive (Rx) mode. Step 3. Connect the cable from the Signal Generator to the RFS cal connector. Use a barrel connector to change the gender, if required. Step 4. Connect the cable from the Spectrum Analyzer to the RFS antenna input number 1. Use a barrel connector to change the gender, if required. See Figure O9.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 192                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 Figure O9:  RFS Only Rx Verification                 Note: The position of the RFS will vary the sweep results due to reflections from the test surface.    Step 5. Take a marker measurement on the Spectrum Analyzer by using the ‘marker to peak’ or the ‘peak search’ function. The screen on the Spectrum Analyzer should look similar to the one shown in Figure O10.  Figure O10:  RFS Only Rx Marker Measurement Example                       Signal Generator cable to RFS cal connector Barrel connector Spectrum Analyzer cable to RFS antenna 1 connector Signal Generator cable to RFS cal connector Barrel connector Spectrum Analyzer cable to RFS antenna 1 connector
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            193 October 23, 2003 Step 6. The marker value should be equal to the RFS Only Rx insertion loss within +/– 2.0 dB, per the manufacturer’s data. If the insertion loss results do not agree with the manufacturer’s data, check the test setup.  Caution: An RFS with results greater than the +/– 2.0 dB limits should not be installed, as a potential hardware fault exists. Contact Navini Networks Technical Support.  Step 7. Record the data in the RFS System Test Form under “RFS RX PATH LOSS (RFS ONLY)”. Ensure that the information is recorded under the channel number that is on the RFS antenna that is being tested. Step 8. Repeat steps 5 through 7 for the remaining seven antenna inputs on the RFS. Step 9. Change the frequency to the next test frequency (refer back to Test Setup). Perform steps 1 through 8 until the RFS has been successfully tested at the frequencies shown in Table O4.  RFS & Cables Transmit Verification  This test is performed after the RFS is installed and the antenna cables, calibration cable, and power/data cable are connected to the inputs on the RFS.    Step 1. Ensure calibration of the test setup and RFS Test Box setup for RFS and cables has been performed each time the test frequency is changed.  Step 2. Switch the RFS Test Box to the Transmit (Tx) mode.  Step 3. Connect the cable from the Spectrum Analyzer to the RFS calibration cable connector. Use a barrel connector to change the gender, if required.  Step 4. Connect the cable from the Signal Generator to the RFS antenna cable number 1 connector. Use a barrel connector to change the gender, if required.  Step 5. Take a marker measurement on the Spectrum Analyzer by using the ‘marker to peak’ or the ‘peak search’ function. The screen on the Spectrum Analyzer should look similar to the one shown in Figure O11.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 194                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 Figure O11:  RFS & Cables Tx Marker Measurement Example                     Step 6. The marker value should be equal to the RFS Only Tx insertion loss + calibration cable loss + antenna cable loss + antenna cable jumper loss. Transmit insertion loss should be within +/– 2.0 dB of the sum of the parts. If the insertion loss results do not agree with the manufacturer’s data, check the test setup and the cable connections.  Caution: If RFS & cables test results are greater than the +/– 2.0 dB limits, they should not be installed on a tower, as a potential hardware fault exists. Verify the connections and contact Navini Networks Technical Support.  Step 7. Record the data in the RFS System Test Form under “TOTAL TX PATH LOSS (CABLE-RFS)”. Ensure that the information is recorded under the channel number that is on the cable label.  Step 8. Repeat steps 5 through 7 for the remaining seven antenna cable inputs on the RFS.  Step 9. Change the frequency to the next test frequency (refer to Test Setup). Perform steps 1 through 8 until the RFS has been successfully tested at the frequencies shown in Table O4.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            195 October 23, 2003  RFS & Cables Receive Verification  This test is performed after the RFS is installed and the antenna cables, calibration cable, and power/data cable are connected to the inputs on the RFS.   Step 1. Ensure that the calibration of the test setup and RFS Test Box setup for RFS and cables has been performed each time the test frequency is changed. Step 2. Switch the RFS Test Box to the Receive (Rx) mode. Step 3. If present, remove the barrel connector from between the Signal Generator and Spectrum Analyzer cables. Step 4. Connect the cable from the Signal Generator to the RFS calibration cable connector. Use a barrel connector to change the gender, if required. Step 5. Connect the cable from the Spectrum Analyzer to the RFS antenna cable number 1 connector. Use a barrel connector to change the gender, if required. Take a marker measurement on the Spectrum Analyzer by using the ‘marker to peak’ or the ‘peak search’ function. The screen on the Spectrum Analyzer should look similar to the one shown in Figure O12. Figure O12:  RFS & Cables Rx Marker Measurement Example                 The marker value should be equal to the RFS Only RX Insertion Loss + Calibration Cable Loss + Antenna Cable Loss + Antenna Cable Jumper Loss. RX Insertion Loss should be within +/– 2.0 dB of the sum of the parts. If the Insertion Loss results do not agree with the manufacturers data, check the test setup and the cable connections.  Caution: If RFS & cables test results are greater than the +/– 2.0 dB limits, they should not be installed on a tower, as a potential hardware fault exists. Verify connections and contact Navini Networks Technical Support.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 196                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Record the data in the RFS System Test Form under “TOTAL RX PATH LOSS (CABLE-RFS)”. Ensure that the information is recorded under the channel number that is on the cable label. Repeat steps 5 through 8 for the remaining seven antenna cable inputs on the RFS. Change the frequency to the next test frequency (refer to Test Setup). Perform steps 1 through 9 until the RFS has been successfully tested at the frequencies given in Table O4.   Procedures – TTA Base Station   Equipment Required  ?? Signal Generator - Agilent 8648D, or suitable alternative, tunable to the RFS center frequency ?? Spectrum Analyzer - Agilent E4404B, or equivalent ?? QMA female to SMA Female adapter ?? SMA male to N-type male test cable (Note: The cable can be changed but additional adapters will be required.) ?? RFS test box for RFS tests only (not required for cable tests) – see Figure O13   Figure O13:  RFS & RFC Test Box   ?? JP1 - Cable port to be connected to the RFC or the RFS. ?? M1/M2 - RFC DC output test points. ?? Load Button - Tests RFC full Current load.  Used in conjunction with Power LED by JP1. ?? RX/TX switch - Supplies power to the RX or RX circuit in the RFS. ?? RFC/RFS switch - Moved to the RFS for testing of the RFS and to the RFC for testing of the RFC. ?? 10.7MHz - Test point to measure the 10.7 MHz signal output of the RFC. ?? J1 - External control of switches. (Engineering use only) ?? P1 - DC power supply connection. (Used for RFS testing only) ?? JP2 - Connection point for test equipment (DC blocked port)
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            197 October 23, 2003  Equipment Set-up  ?? Spectrum Analyzer - connected to the test cable / QMA adapter on BTS end Center Frequency:     Set to frequency to be tested Span:    10 MHz Resolution Bandwidth: 100 KHz Video Bandwidth:    100 KHz Sweep Time:   Auto  ?? Signal Generator  - connected to the RFS cable end Frequency:   Set to frequency to be tested Signal Level:   0 dB   Equipment Calibration  Refer to Figure O14 to calibrate the test equipment.  Step 1. Perform “Equipment Set-Up”. Step 2. Connect the test cable from the “RF Output” of the Signal Generator to the “RF input” of the Spectrum Analyzer. Step 3. Turn on the RF output of the Signal Generator. Step 4. Perform a “peak search” on the Spectrum Analyzer. Step 5. Set a Delta point. The Delta sets a zero point on the Spectrum Analyzer so that when any additional cable or equipment is added to the link the new loss reading can be recorded. (Note: If the Spectrum Analyzer does not have a Delta function, increase the output of the Signal Generator until there is a 0 dB reading on the Spectrum Analyzer.)  Figure O14:  Calibrate Test Equipment          Signal Generator Spectrum AnalyzerTest cable
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 198                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  RF Cable Sweeps Procedure  This section provides step-by-step procedures for calibrating the test equipment and performing insertion loss measurements of the RF cable. Refer to Figure O15.  Step 1. Calibrate the test equipment. Step 2. Connect Signal Generator to cable 1 on the RFS side to the RF cable. Step 3. Connect spectrum analyzer to cable 1 on BTS side of RF cable. This will be done with the test cable and the QMA/SMA adapter.  Step 4. Enable the RF on the signal generator. Step 5. From the Delta marker found in Step 1 take the loss reading in db. Record the results. Step 6. Perform steps 2 through 5 for all cables.  Figure O15:  RF Cable Test  RF CableBTS End RFS EndQMA N-Type   RFS Test Procedure  This procedure is performed twice for an installation. The first sweep is performed prior to mounting the RFS on the tower. This test verifies that all the equipment is in tact from shipment. These sweeps will need to be compared to the factory sweeps that are shipped with the RFS.   The second sweep is performed after the RFS has been mounted on the tower and the RF cables have been connected. This sweep verifies that no damage was done to the RFS when hoisting it, and that the RF cables are properly connected to the RFS.  Step 1. Perform the “Equipment Set-up”.    Note:  When performing the transmit (TX) side tests on the RFS, the signal level from the Signal Generator needs to be lowered to at least –20 dB. The RFS has protection circuits built in and will disable the PAs in the RFS if the incoming signal is too high.   Step 2. Perform the “Equipment Calibration”. Step 3. Configure the test equipment as shown in Figure O16. ?? Spectrum Analyzer to the Cal Port ?? Signal Generator to the test equipment port of the test box. ?? Test box RFC/RFS port to the antenna
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            199 October 23, 2003  Figure O16:  Transmit Side                  Step 4. Set the test box to RFS and TX. Step 5. From the Delta marker established during the calibration, record the insertion loss dB level.   Step 6. Perform Step 5 for all eight antennas. Step 7. Set the Signal Generator output level to 0 dB and recalibrate the test equipment. Step 8. Configure the test equipment as shown in Figure O17. ?? Signal Generator to the Cal Port ?? Spectrum Analyzer to the test equipment port of the test box. ?? Test box RFC/RFS port to the antenna  Figure O17:  Receive Side  Signal GeneratorSpectrum AnalyzerTest cableRFS1234 5678calTest cableTest cable    Signal GeneratorSpectrum AnalyzerTest cableRFS1234 5678calTest cableTest cable
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 200                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 Step 9. Set the test box to RX. Step 10. From the Delta maker set on calibration, record the insertion loss value from the Spectrum Analyzer.   Step 11. Repeat Step 10 for all eight antennas.  Compare all recorded TX and RX values with the factory sweep results that are shipped with the RFS. If there is a mismatch, contact Navini Technical Support.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            201 October 23, 2003  2.4 RFS System Test Form (Combo & Split Chassis)  RFS SNNAMEDATEMEASUREMENT DESCRIPTIONCHANNELRFS TX PATH LOSS (RFS ONLY)1----0.00RFS TX PATH LOSS (RFS ONLY)2----0.00RFS TX PATH LOSS (RFS ONLY)3----0.00RFS TX PATH LOSS (RFS ONLY)4----0.00RFS TX PATH LOSS (RFS ONLY)5----0.00RFS TX PATH LOSS (RFS ONLY)6----0.00RFS TX PATH LOSS (RFS ONLY)7----0.00RFS TX PATH LOSS (RFS ONLY)8----0.00RFS RX PATH LOSS (RFS ONLY)1----0.00RFS RX PATH LOSS (RFS ONLY)2----0.00RFS RX PATH LOSS (RFS ONLY)3----0.00RFS RX PATH LOSS (RFS ONLY)4----0.00RFS RX PATH LOSS (RFS ONLY)5----0.00RFS RX PATH LOSS (RFS ONLY)6----0.00RFS RX PATH LOSS (RFS ONLY)7----0.00RFS RX PATH LOSS (RFS ONLY)8----0.00JUMPER LOSS1----0.00JUMPER LOSS2----0.00JUMPER LOSS3----0.00JUMPER LOSS4----0.00JUMPER LOSS5----0.00JUMPER LOSS6----0.00JUMPER LOSS7----0.00JUMPER LOSS8----0.00JUMPER LOSSCAL----0.00MAIN FEEDER LOSS1----0.00MAIN FEEDER LOSS2----0.00MAIN FEEDER LOSS3----0.00MAIN FEEDER LOSS4----0.00MAIN FEEDER LOSS5----0.00MAIN FEEDER LOSS6----0.00MAIN FEEDER LOSS7----0.00MAIN FEEDER LOSS8----0.00MAIN FEEDER LOSSCAL----0.00TOTAL CABLE RUN LOSS1-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS2-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS3-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS4-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS5-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS6-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS7-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS8-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSSCAL-0.00-0.00-0.00-0.00TOTAL TX PATH LOSS (CABLE-RFS)1----0.00TOTAL TX PATH LOSS (CABLE-RFS)2----0.00TOTAL TX PATH LOSS (CABLE-RFS)3----0.00TOTAL TX PATH LOSS (CABLE-RFS)4----0.00TOTAL TX PATH LOSS (CABLE-RFS)5----0.00TOTAL TX PATH LOSS (CABLE-RFS)6----0.00TOTAL TX PATH LOSS (CABLE-RFS)7----0.00TOTAL TX PATH LOSS (CABLE-RFS)8----0.00TOTAL RX PATH LOSS (CABLE-RFS)1----0.00TOTAL RX PATH LOSS (CABLE-RFS)2----0.00TOTAL RX PATH LOSS (CABLE-RFS)3----0.00TOTAL RX PATH LOSS (CABLE-RFS)4----0.00TOTAL RX PATH LOSS (CABLE-RFS)5----0.002400MHz2440MHz2473MHzAVERAGE2.4 GHz RFS INSTALLTEST RESULT FORM
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 202                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  2.6 RFS System Test Form   RFS SNNAMEDATEMEASUREMENT DESCRIPTIONCHANNELRFS TX PATH LOSS (RFS ONLY)1----0.00RFS TX PATH LOSS (RFS ONLY)2----0.00RFS TX PATH LOSS (RFS ONLY)3----0.00RFS TX PATH LOSS (RFS ONLY)4----0.00RFS TX PATH LOSS (RFS ONLY)5----0.00RFS TX PATH LOSS (RFS ONLY)6----0.00RFS TX PATH LOSS (RFS ONLY)7----0.00RFS TX PATH LOSS (RFS ONLY)8----0.00RFS RX PATH LOSS (RFS ONLY)1----0.00RFS RX PATH LOSS (RFS ONLY)2----0.00RFS RX PATH LOSS (RFS ONLY)3----0.00RFS RX PATH LOSS (RFS ONLY)4----0.00RFS RX PATH LOSS (RFS ONLY)5----0.00RFS RX PATH LOSS (RFS ONLY)6----0.00RFS RX PATH LOSS (RFS ONLY)7----0.00RFS RX PATH LOSS (RFS ONLY)8----0.00JUMPER LOSS (Measured)1----0.00JUMPER LOSS (Measured)2----0.00JUMPER LOSS (Measured)3----0.00JUMPER LOSS (Measured)4----0.00JUMPER LOSS (Measured)5----0.00JUMPER LOSS (Measured)6----0.00JUMPER LOSS (Measured)7----0.00JUMPER LOSS (Measured)8----0.00JUMPER LOSS (Measured)CAL----0.00MAIN FEEDER LOSS (Measured)1----0.00MAIN FEEDER LOSS (Measured)2----0.00MAIN FEEDER LOSS (Measured)3----0.00MAIN FEEDER LOSS (Measured)4----0.00MAIN FEEDER LOSS (Measured)5----0.00MAIN FEEDER LOSS (Measured)6----0.00MAIN FEEDER LOSS (Measured)7----0.00MAIN FEEDER LOSS (Measured)8----0.00MAIN FEEDER LOSS (Measured)CAL----0.00TOTAL CABLE RUN LOSS (Measured)1-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS (Measured)2-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS (Measured)3-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS (Measured)4-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS (Measured)5-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS (Measured)6-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS (Measured)7-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS (Measured)8-0.00-0.00-0.00-0.00TOTAL CABLE RUN LOSS (Measured)CAL-0.00-0.00-0.00-0.00TOTAL TX PATH LOSS (CABLE-RFS)1----0.00TOTAL TX PATH LOSS (CABLE-RFS)2----0.00TOTAL TX PATH LOSS (CABLE-RFS)3----0.00TOTAL TX PATH LOSS (CABLE-RFS)4----0.00TOTAL TX PATH LOSS (CABLE-RFS)5----0.00TOTAL TX PATH LOSS (CABLE-RFS)6----0.00TOTAL TX PATH LOSS (CABLE-RFS)7----0.00TOTAL TX PATH LOSS (CABLE-RFS)8----0.00TOTAL RX PATH LOSS (CABLE-RFS)1----0.00TOTAL RX PATH LOSS (CABLE-RFS)2----0.00TOTAL RX PATH LOSS (CABLE-RFS)3----0.00TOTAL RX PATH LOSS (CABLE-RFS)4----0.00TOTAL RX PATH LOSS (CABLE-RFS)5----0.002.6 GHz RFS INSTALLTEST RESULT FORMAVERAGE
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            203 October 23, 2003    Appendix P:  Chassis Alarms    The chassis contains two connectors that are used to send alarm indications to the BTS.  One of the connectors, labeled CABINET ALARM, is used to trigger alarm conditions that occur within the external chassis. The second connector, labeled BBU, is used to process alarms from the battery backup unit.  Both connectors contain six pins, which are numbered as shown in Figure P1.  This figure also shows the CAL and GPS-B connectors for size reference.  Figure P1:  Pin Orientation    1 2 34561 2 3456
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 204                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  The alarm connector uses only four of the six pins.  The pin names can be found in Table P1.  Table P1:  Pin Names  Pin Name 1  General Fail Alarm 2  Ground reference for General Fail Alarm 3  Door Open Alarm 4  Ground reference for Door Open Alarm 5  Not Connected 6  Not Connected   The first pin of the alarm connector is the General Fail Alarm.  This signal should be left open to indicate an alarm condition from the HMC module located in the outdoor chassis. If no alarm condition exists, this pin should be driven low. Pin 2 is used as the ground reference for this alarm. The second alarm sent to the chassis is located on pin 3, Door Open Alarm. This signal should be driven low when the door is closed. To indicate that the door of the outdoor chassis is open, this signal should be left open. The associated ground reference for this signal is taken from pin 4.  The BBU connector contains four alarm signals. These signal names are listed in Table P2.  Table P2:  BBU Signal Names    Pin Name 1  Digital Ground Reference 2  BBU Battery Low 3  BBU Rectifier Fail 4  BBU AC Line Fail 5  BBU Charge Fail 6  Analog Ground Reference  The first alarm signal is located on pin 2, BBU Battery Low. If the BBUs battery is running low, the signal on pin 2 should be left open. BBU Rectifier Fail alarm is the next alarm and is located on pin 3. This signal should be left open to indicate a failure on the Battery Backup Unit’s rectifier. The next alarm condition occurs if the AC Line to the BBU fails. In this condition, signal BBU AC Line Fail on pin 4 should be left open. If the BBU is unable to hold a charge, then the BBU Charge Fail signal on pin 5 should be left open. For non-alarm conditions (normal operation), these signals should be driven low. The digital ground reference for these signals is located on pin 3. The analog ground reference should be located on pin 4.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            205 October 23, 2003    Appendix  Q:  Sample Tri-sector BTS Grounding   Refer to the Regulatory Information in Chapter 1, Page 8, regarding UL and NEC/CEC compliance.             Power / DataCable LightningProtectorsPower SystemDistribution Panel(Will vary perManufacture)Navini RFSBuilding steel,Centerpoiseground, or towerstructureSame Centerpoiseground system <5 ohmAPPROXIMATE GROUNDLINE LUG TYPE ANDQUANTITY#6AWG 1 HOLE = 12#6AWG 2 HOLE = 20#2AWG 2 HOLE = 2+POWER RACKSPACE ANDCONFIGURATIONWILL VARY PERVENDOR
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 206                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            207 October 23, 2003    Appendix  R:  Sample Tri-sector BTS Power   Refer to the Regulatory Information in Chapter 1, Page 8, regarding UL and NEC/CEC compliance.       REQUIRED DC  BREAKERAMPERAGE AND QUANTITY3 X 50A - FOR RF SHELF3 X 20A FOR DIGITAL SHELFAPROXIMATE DC LINE LUGTYPE AND QUANTITY#6AWG 1 HOLE = 12#6AWG 2 HOLE = 12POWER RACKSPACE ANDCONFIGURATIONWILL VARY PERVENDOR
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 208                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            209 October 23, 2003    Appendix  S:  Single Antenna Test Procedure   Objective  The object of the RFS Single Antenna Test Procedure is to verify the functionality of each antenna element in the Ripwave Radio Frequency Subsystem (RFS). The 8 antenna elements work together to create the beamforming that results from using a Smart Antenna - Phased Array technology. Using 8 combined single antenna elements creates the beamed radiation that is part of what constitutes the gain of up to 18 dB during transmission of data.  Each antenna element has an associated (and hard cabled) RF/Power Amplifier (PA) card in the Base Transceiver Station (BTS). In order to verify the correct beamforming and that each single antenna is working properly, we have to turn off the individual PA that controls each antenna element, one at a time.  The Single Antenna Test should be performed after completing an equipment check and after performing the Base Station Calibration Verification* procedure described in the Ripwave Base Station Installation & Commissioning Guide. This test is necessary since an equipment check does not check the functionality of the RFS, and the Calibration Verification only sweeps for losses in the RFS, not RFS functionality.   *Note: The Calibration Verification, where you check both transmit power and receive sensitivity, is also sometimes referred to as the RF Sanity test.  More specifically, the Single Antenna Test checks the following:  1.  Low Noise Amplifier (LNA) at the RFS. LNAs are an integral part of the smart antenna technology.  2.  Power Amplifiers. Each PA is a module in the BTS RF shelf that creates the RF transmission. With one per element, there are a total of 8 PAs in the shelf. The transmission is measured in dBm. This is what makes possible the transfer of data over-the-air.  3.  Modulations. As each antenna element is checked, the variable modulations are tested. The higher the modulation, the higher the power and the better the data rate. The test ensures that all modulations possible, i.e., QPSK, 8PSK, and QAM16, are working properly.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 210                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Panel Procedure  Overview  Assuming the equipment has been installed and you have performed the calibration verification, if the results were erroneous this Single Antenna Test will not be valid. It is important to complete those two steps successfully before continuing.  For this test you will need two people. One person will verify the reception (Rx) of each antenna using the Constellation Debugger Tool and a Modem. The following summarizes what will happen during this test:  1.  Person A will stay where the BTS or EMS is located. This person will control each PA in the BTS to be tested.  2.  Person B will be in the field. This person will pick a complete Line of Sight (LOS) test point to the RFS (antenna). Person B will use the Constellation Debugger software supplied by Navini. This software allows the tester to verify functionality.  3.  Once the two people are in place, start by turning all antennas off except for Antenna #1. NOTE: It does not matter which antenna you start with as long as the tester can keep track of which ones have been tested and each one’s results.  4.  With only one antenna powered on, Person B verifies the transmission, modulation, and signal strength of the single antenna. Person B verifies this information for at least 30 seconds.  5.  When the first antenna is checked, Person A saves the file and waits for Person B to power on Antenna #2.  6.  Steps 3 through 5 are repeated for each antenna element.  Details  The following provides more detail for each step, and includes snapshots of what to change and what to measure.  Step 1. After calibration verifications are successful, in EMS click on the BTS tab and highlight the specific BTS. Go to Air Interface > Layer 1, and click on the Antenna Table tab (Figure S1). This window will show all antennas and their PA status.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            211 October 23, 2003  Figure S1:  Antenna Tab    Step 2. After checking that all PAs are up and running, next click on Configure (Figure S2). This function will take you to the configuration mode of this particular window.  Figure S2:  Configure Antenna Table
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 212                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Step 3. Click on the button, Modify All. This function will allow you to modify all antennas and PAs at the same time. Notice that this window allows you to configure any column shown here. For our purpose we will only use the second column, Admin Status (Figure S3). This column shows the state of each PA that controls each antenna in the RFS. “Up” means the antenna and PA are on and functioning. “Down” means the antenna and PA are off and not transmitting.  Figure S3:  Modify All    Step 4. Next, turn off (no transmission) all of the antennas and PAs except for Antenna #1. This begins the verification of this antenna. Refer to Figure S4. When only Antenna #1 is powered up and transmitting, the second person will verify at the other end that the antenna is actually transmitting information to the Modem. This can be completed by doing a Ping at the Modem side.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            213 October 23, 2003  Figure S4:  Antenna #1 On      Step 5. Start a Ping with the Modem and PC performing the test, observing the Constellation Debugger tool. Look for the following values:  ?? ACC Signal Strength ?? Absolute Sync Signal ?? Processed Sync Signal  These values, an example of which is shown in Figure S5, give you an indication if there is something wrong with the antenna. If the values are too low or you do not see a response from your Ping, it means that the antenna and/or the PA are not functioning properly.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 214                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Figure S5:  Constellation Debugger Values     Step 6. Repeat Steps 4 and 5 to verify each one of the antennas and the PAs. The verification of each antenna concludes the testing procedure.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            215 October 23, 2003  Comments & Suggestions   1.  Navini Smart Antenna technology uses all the 8 antenna elements for the optimum performance of the system. It is recommended that all antennas are verified and working properly. If one of the antennas or PAs malfunctions or it breaks, the RFS will still work. It will not work at its optimum operation, but it will still be functioning equipment. It is recommended that you change or swap the bad board or equipment.  2.  For the testing of each antenna it is recommended that you pick only one spot to measure the Rx side of the RFS. This spot must to be at a distance of 2-3 km with clear line-of-sight.  3.  A difference of more than 2 dB between the Absolute and Processed SYNC Signal strength, typically indicates the presence of multipath in the environment.   Omni Procedure   <This info will be added at a later date>
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 216                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            217 October 23, 2003    Appendix T:  Base Station Installation Certification     COMPANYSITE NAMESITE NOLOCATIONSITE TYPEANTENNA TYPE  ANTENNA AZIMUTHFREQUENCY BANDBTS CENTER FREQUENCYRFS ELECTRICAL DOWNTILTRFS MECHANICAL TILTRFS OVERALL DOWNTILTBTS ENCLOSUREA1Equipment Installed and Secured Per Plan2Roof/Ceiling/Wall Penetrations Patched, Sealed and Painted3Penetration(s) Inspected by Landowner RepresentativeB1Equipment Installed and Secured Per Plan2Structural Upgrades to Roof Installed Per Plan3Equipment Support Frame InstalledC1Equipment Installed and Secured Per Plan2Special Inspection for Foundation Steel Complete3Concrete Placed and Vibrated4Concrete Break Test Report CompleteD1Fencing Complete (Tie-In to Ground System) Per Plan2Gravel/Crushed Rock Placed over Weed Barrier3Above Ground Conduits Installed Plumb4Landscaping/ Erosion Control Complete Per Plan5Access Road Complete Per Plan6All Trash and Debris Hauled Off Site7Site Area restored to Original Condition8Unistruts, iron angles and Rods properly cold galvanized9RF Safety Signage Installed where Required BTS SITE COMPLETION CERTIFICATIONEquipment Installed in BuildingEquipment Installed on RoofEquipment Installed on GradeCivil/Site WorkYESNON/AYESNON/AYESNON/AYESNOYESNON/AYESNON/AYESNON/AYESNOYESNON/AYESNON/AYESN/AYESNON/AYESNONON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNOMONOPOLECO-LOCATEOMNISECTORIZEDINDOOROUTDOOROTHEROTHER2.4GHz2.3GHz2.5GHz2.6GHz0 Degree2 Degree4 Degree6 DegreeUptiltDowntilt
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 218                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  E1Monopole/Tower Plumb, Torqued and Free of Visible Defects2Orientation of Monopole/Tower Per Plan3Safety Climb Installed and Tensioned per Manufacturer Spec.4Weep Hole Free of Obstructions5Step Bolts Installed/ Removed Below 30 feet6Monopole/Tower Tie-In to Ground Ring CompleteF1Monopole/Tower Grounding Installed2Ground Wire Types and Size meet construction Specs3Lightning Rod Provided and Installed Per Plan45 Ohm Megger Ground Resistance Test Complete5Buss Bars Installed Per Plan6Surge Protector Installed Between RFS Antenna and Cable7Coax Ground Kits Installed at RFS Antenna Per Plan8Coax Ground Kits Installed at Tower Base Per Plan9Coax Ground Kits Installed at Buss Bar Prior to BTS Per Plan10Double Lug Connectors Used at All Buss Bar Attachments11Cable Tray/Ice Bridge Bonded and Grounded to Buss Bar12Surge Protectors Mounted and Secured on ground Buss Bar13 Master Ground Buss Bar Tied-In to Ground Ring14Equipment Rack Ground Per Plan15Power Supply/UPS, Rectifier Ground Per Plan16Meter and Telco box Ground Per Plan17Fence Work Grounded Per Plan18Additional Equipment Tied-In to BTS properly GroundedG1Power and Telco Conduits Installed Per Plan2Conduits Are Labeled and Pull Strings are Provided3Meter and Telco Box are Installed Per Plan4Circuit Breakers Installed and Properly Labeled5UPS Installed and All Internal Connections Made6Rectifier Installed, Output and Wiring to BTS Checked7Telco Tie-In to Source, Tested and Complete8Network/Telco Tie-In to BTS, Tested and Complete9EMS Installed and Connected to NetworkElectrical, Telco and NetworkGroundingMonopole/TowerN/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNO
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            219 October 23, 2003  H1Cabinet is Positioned, Secured and Leveled Per Plan2Cabinet Outer Surfaces Free from scratches, dents, corrosion3All Hardware Connections within BTS are tightened/secured4RF/GPS Coax Connectors Securely Connected to BTS5Signal/Power Cable Securely Connected to BTS6Ethernet/T1 cables Dressed and Secured to BTS7Documents, License are Stored or Posted on BTSJ1RFS Antenna Height and Orientation Per Plan2RFS Antenna Mount Plumb Per Axis3GPS Antenna Mounted Per Plan4Zinc Cold Galvanizing compound used everywhere 5Coaxial Cables Run Straight  (Not Exceeding Bend Radius)6Coaxial Cables Tagged and Color Coded Per Plan7Connectors and Jumpers Installed and Weatherproofed8Cable Hangers, Bands or Ties Spaced up every 3 Feet9Antenna Power and Data Cable Continuity Tested10Antenna System Sweep Test Performed and Passed11SW and Hard Copy of Antenna Sweep Test Results ProvidedPrinted NameSignature / DateCompanyPhone No.Printed NameSignature / DateCompanyPhone No.Printed NameSignature / DateCompanyPhone No.BTS SystemAntenna and Feeder SystemNOTESN/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNON/AYESNO
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 220                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003   COMPANYSITE NAMESITE NOLOCATIONCHP1 CHP2 MDM1 MDM20000BTS SNRFS SN00000000000RF SHELFDIGITAL SHELFSYN1PA4PA5IF1IF2CHP1PA1PA2PA30SYN2PA7PA8SYN1 SYN2 IF1 IF2 CC1 CC200PA2PA4PA5Note :  Please write all Card Serial Numbers in the Spreadsheet BelowPA1PA3PA60000
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            221 October 23, 2003    Appendix U:  Excel Configuration Form   The configuration forms are used to plan and design the operating parameters for the system. The parameters for every system element are defined in the EMS Server.   **********  EMS Configuration Data Form (To configure EMS Servers & Clients in the Ripwave System)  Company:__________________________________________________________ Your Name:______________________________________  Date:_____________  NOTE 1: Field Values in gray rows indicate data that ordinarily should not be changed or that is populated automatically by the system.  NOTE 2: Default Field Values are underlined.   Field Name Values Description EMS Id  Unique identifier for this EMS. Alarm AutoAck True True or False. If True, the EMS will automatically acknowledge all alarms except alarms with a severity level of Warning (blue). An Alarm Engineer will only see current alarms on the system. However, all alarm activity is logged to an alarm file. Server Ip Address  IP address of the EMS Server. Database Schema Version 01 (example) Version of the EMS server database schema. Mib Version 1.19.01 (example) Version of the BTS Management Information Base (MIB). BTS/CPE SW Directory loads (example) Directory where BTS and CPE software loads are stored. Used by the EMS to obtain the location of the software loads during downloads. Copy BTS and CPE software loads to this directory during initial installations or upgrades. Otherwise, the EMS cannot download the software to the BTS. This field is used in conjunction with the FTP Server Root Path field by the EMS to obtain the software loads. The full path the EMS searches for software loads is <FTP Server Root Path>\<BTS/CPE SW Directory>. Example - C:\naviniems \ftp\loads. continued…
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 222                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Field Name Values Description FTP Server Root Path  The Root directory where BTS and CPE software loads are stored. This field must match what is configured in the FTP Daemon. Otherwise, the EMS will not be able to download BTS and CPE software loads to the BTS. This path is used by the EMS to obtain the location of the software loads during downloads. Copy BTS and CPE software loads to this root directory during initial installations or upgrades. This field is used in conjunction with the BTS/CPE SW Directory field by the EMS to obtain the software loads. The full path the EMS searches for software loads is <FTP Server Root Path>\<BTS/CPE SW Directory>. Example - C:\naviniems \ftp\loads. Network ID  Unique identifier for this Service Provider’s wireless network. Intended to ensure other Service Providers’ CPEs cannot operate in the identified network. A CPE with a different BTS network ID cannot be provided service by that BTS. Server Name  Host name of the EMS Server machine. EMS Version 1.19.01 (example) Version of the EMS Server software. Idl Build Number 1.18.09 (example) CORBA networking software IDL version used by the EMS Server. BTS/CPE SW Ftp User Name  User name for downloading BTS and CPE software from the EMS. This field must match what is configured in the FTP Daemon. Otherwise, the EMS cannot download BTS and CPE software loads to the BTS. BTS/CPE SW Ftp Password  Password used when downloading BTS and CPE software. This field must match what is configured in the FTP Daemon. Otherwise, the EMS cannot download BTS and CPE software loads to the BTS. Confirm Password  Password must be re-entered for security purposes. CPE AutoProvisioning Disabled Enable or Disable. Determines if the EMS is in AutoProvision mode during CPE registration. If enabled, the EMS will allow unprovisioned CPEs to access the system with minimum bandwidth for a short period of time. The minimum bandwidth is defined by the first entry in the CPE Descriptor table. Once the CPE is allowed limited access to the system, it can connect to a default web site to enter billing information and the CPE can be provisioned automatically with the EMS. If disabled, the EMS will NOT allow an unprovisioned CPE to access the system.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            223 October 23, 2003 BTS Configuration Form  Company:_________________________________________________________ Your Name:______________________________________  Date:____________ BTS ID/NAME:____________________________________________________  NOTE 1: Field Values in gray rows indicate data that ordinarily should not be changed or that is populated automatically by the system.  NOTE 2: Default Field Values are underlined.  General Parameters  Status  Field Name Values Description RF Admin Status Up or Down Determines if the BTS is transmitting Radio Frequency (RF). Up means transmitting. Down means not transmitting. To bring the RF Admin Status Up, execute the Enable action. To bring it Down, execute the Disable action. Connected Status True or False Display only. The user cannot set this field. Indicates if the EMS can communicate with the BTS. The EMS Server sends a message to the BTS periodically. If the BTS responds, the EMS sets this field to True. If the BTS does not respond in a reasonable amount of time, the EMS changes the Connected Status to false. If the Connected Status is False, the EMS will not send any configuration messages to the BTS because it cannot communicate. Provisioned Status Provisioned or Unprovisioned If Provisioned, the BTS has been configured and is ready for use.   IP  Field Name Values Description BTS IP Address  Unique IP address for each BTS. Space bar used to remove or skip existing digits. EMS Server IP Address  Unique IP address for an EMS. Defaults to the IP on which the EMS Server is running. Space bar used to remove or skip existing digits. BTS Default Gateway  Default Gateway used to route IP packets for a BTS. BTS Subnet Mask  Subnet Mask used to route IP packets for a BTS. Street Address  Physical location of this BTS. City  City in which BTS is located. State  State in which BTS is located. Zip  Zip code for location in which BTS is located continued…
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 224                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Field Name Values Description BTS ID  Unique numeric identification number for this BTS. Cannot be changed once the BTS is created in the system. BTS Name  Unique name given to this BTS. No two BTSs can have the same name. Suppress Alarms TRUE or FALSE To suppress alarms from BTS to EMS, set to TRUE until problem is resolved. Useful if BTS is flooding EMS and affecting its performance. To allow alarms to be sent, set to FALSE. Suppress CPE Registration TRUE or FALSE Determines if BTS can send CPE Registration messages to EMS. Useful if BTS is flooding EMS and affecting its performance. To allow messages to be sent, set to FALSE. Calibration Interval (hours) 1 - 24 The interval of hours by which on-line calibration occurs. Bridge Aging Timer (minutes) 1 - 60 BTS Bridge Table timer that controls how long a PVC is assigned to an EID (CPE). The PVC to EID association is removed when no user traffic is received for the timer interval. Applicable only when dynamic PVC assignment is used. Enable PVC Loopback TRUE or FALSE Determines if any PVC on this BTS can perform loopback test. BTS Contact Personnel  Textual identification of a contact person for this BTS and how to contact them. BTS Configuration Source EMS or BTS Determines where the BTS obtains its configuration data when reset. If provisioning BTS for first time, set to EMS. After successful reset, defaults to BTS. Interface Type Ethernet or ATM Indicates the backhaul to which the BTS is connected. BTS Profile Type Unlicensed 2.4 GHz MMDS 2.6 GHz Select the correct system. 2.4 GHz is the only unlicensed frequency. Any other system, 2.3, 2.5, and 2.6, select MMDS. Frequency 2.305 GHz - 2.359 GHz  2.40 GHz - 2.473 GHz  2.50 GHz - 2.595 GHz  2.602 - 2.686 GHz Scroll bar that allows you to set the center frequency for the BTS operation. The range depends on the type of system, i.e., 2.3 GHz, 2.4 GHz, 2.5 GHz, 2.6 GHz. The field is operated by dragging the slider of the center frequency scroll bar left or right. The center frequency of an MMDS band BTS must match what is hard-wired on the RFS. During installation, the installers should check that the configured center frequency is identical to the center frequency labeled on the Channel Filter component of the RFS.           CAUTION:  Changing an MMDS BTS center           frequency may result in destruction of the PAs.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            225 October 23, 2003  Diagnostics  Field Name Values Description Enable Const Display True or False Determines if the BTS Constellation Display application can be logged into and used on this BTS. If set to True, this BTS can be logged into and its Constellation Display viewed. Max Beamform Displays 0-9 The maximum number of CPEs  that can be viewed simultaneously using the BTS Beamforming diagnostic display. User Name ems  Authorized user of all diagnostic tools. Password  The password used to authenticate the login to all diagnostic tools. Enable Spec Analyzer Display True or False Determines if the BTS Spectrum Analyzer (frequency) application can be logged into and used on this BTS. Confirm Password  Confirms that the correct password is entered.    Performance  Field Name Values Description Perf Log Server IP Address  IP address of the performance log collection server. Perf Log Storage Directory  The name of the directory at the Performance Log server where the performance logs are to be sent. Note: The location of the log directory is “<ftp root directory>\<pm data directory>”. Example: If the FTP root directory is set to “d:\naviniems \ftp” and the pm data directory is set to “performance”, the location of the log directory will be “d:\naviniems \ftp\performance”. Therefore, when configuring the FTP Daemon, set the FTP root directory to “<ems install directory>\ftp”. Upload Interval (minutes or hours) Disable, 15 minutes, 30 minutes, 1 hour, 2 hours, etc. The interval that the BTS uploads performance data to the EMS. Collection Interval (minutes or hours) Disable, 15 minutes, 30 minutes, 1 hour The interval that the BTS collects the performance logs. Perf Log FTP User Name  The FTP user name set in the FTP Daemon running on the server where performance logs are captured. Perf Log FTP Password  The FTP password set in the FTP Daemon running on the server capturing performance logs. Confirm Password  Re-enter password to confirm authorized access.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 226                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  GPS  Field Name Values Description GPS Latitude North or South 0 (deg) 0 (min) 0 (sec)  The latitude of the BTS in degrees, minutes, and seconds. GPS Longitude East or West  0 (deg) 0 (min) 0 (sec)  The longitude of the BTS in degrees, minutes, and seconds. GPS Height (cm) 0 The height of the BTS in centimeters. GPS Gmt Offset (min) -360 The difference in time (minutes) between Greenwich Mean Time (GMT), which is zero, and the time zone where the BTS is located. For example, if the BTS is located in Dallas, Texas, the local time is 6 hours earlier than GMT. In this example, you would enter -360, which is 6 hrs x 60 min. If the local time is ahead of GMT, you would enter a + in front of the number.    Neighbor BTS Frequency List  Field Name Values Description Center Frequency (Scroll Bar) 2.305 GHz - 2.359 GHz  2.40 GHz - 2.473 GHz  2.50 GHz - 2.595 GHz  2.602 - 2.686 GHz  The frequency at which the neighboring BTS is transmitting. Co-located Checkmark or blank Click to place a checkmark indicating that the neighboring BTS is located on the same tower as the current BTS.    CPE Ping Table  Field Name Values Description Ping Sequence 0, 1, 2, 3, etc. Order in which the element with this IP address is pinged. IP Address  IP address of the element being added to the Ping Table. Display String Alphanumeric (up to 30 characters) User-assigned designation (name/string) for this element.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            227 October 23, 2003  Air Interface Parameters  Layer 1 - General  Field Name Values Description RFS Active or Passive Specifies whether the RFS has active or passive circuitry. Gps Offset 0 This is the GPS timing offset to apply to the BTS in order of chips (2.5us). The GPS offset must be different for each BTS sharing the same frequency so they do not interfere with each other. Sync Scale 0.1125 The scale setting applied to the transmitted synchronization signal. Acc Scale 0.0557 The scale setting applied to the Access Channel. Tcc Scale 0.0197 The scale setting applied to the Traffic Channel. Max Scale 0.2516 The maximum allowable scale setting for each of the above scales: Sync, ACC, TCC. Rx Sensitivity (–dBm) 100.0 The target Receiver sensitivity for each antenna. This target is used during full calibration. If it is changed, full calibration must be performed for it to take effect. Antenna Power (dBm) 30.0 The target antenna power for each antenna. This target is used during full calibration. Cal Cable Loss (dB) 0.0 Entered in the EMS during commissioning as one of several inputs for performing full calibration. This value is the measured calibration cable loss. If it is changed, full calibration must be performed for it to take effect. Cal Backplane Loss (dB) 5.0 Calibration Backplane Loss (dB) Cal Total Loss (dB) 0.0 Displays the total calibration loss, calculated from the values in Cal Cable Loss and Cal Backplane Loss fields. Synthesizer Tx Gain  Displays the Transmitter gain setting for the Synthesizer used during calibration. This field is a result that is automatically returned from full calibration. Synthesizer Rx Gain  Displays the Receiver gain setting for the Synthesizer used during calibration. This field is a result that is automatically returned from full calibration. Synthesizer Sc Gain  Displays the Loopback gain setting for the Synthesizer used during calibration. This field is a result that is automatically returned from full calibration. Synthesizer Level  Displays the power level of the Synthesizer.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 228                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Layer 1 - Antenna Table  Field Name Values Description Antenna Index 1-8 The number of the antenna (1-8) that maps to a specific antenna element in the RFS. Admin Status Up or Down Determines if the antenna is transmitting RF. Up means transmitting; Down means not transmitting. Power Splitter_I  The real element of the calibrator board characteristics that is found in the RFS. This information captures the loss and phase information of the board. The Power Splitter data is unique to each RFS. An RFS Configuration CD ships with the equipment. It provides an RFS script and instructions for selecting the correct value to match the specific RFS that is physically installed with the BTS. Power Splitter_Q  The imaginary element of the calibrator board that is found in the RFS. This information captures the loss & amplitude information of the board. The Power Splitter data is unique to each RFS. An RFS Configuration CD ships with the equipment. It provides an RFS script and instructions for selecting the correct value to match the specific RFS that is physically installed with the BTS. RF Tx Gain 0-255 The Transmit gains for each antenna element, ranging from 0-255, with 0 being the lowest gain. This data is returned as a result of full calibration. RF Rx Gain 0-255  The Receive gains for each antenna element, ranging from 0-255, with 0 being the lowest gain. This data is returned as a result of full calibration.    Layer 1 - w0 Table  Field Name Values Description Sub Carrier Id 1-5 The number (ordinal) of the subcarrier pair. Antenna Index 1-8 The number of the antenna element. W0 Weight_I  Real elements of the vector used to control ACC spatial pattern. W0 Weight_Q  Imaginary elements of the vector used to control ACC spatial pattern.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            229 October 23, 2003 Layer 1 - Calibration Table  Field Name Values Description Sub Carrier Id 1-10 The number (ordinal) of the subcarrier. Antenna Index 1-8 The number of the antenna element. Tx Weight_I  Real elements of the vector used while transmitting to control ACC spatial pattern. This data is returned as a result of any of the calibration modes. Tx Weight_Q  Imaginary elements of the vector used while transmitting to control ACC spatial pattern. This data is returned as a result of any of the calibration modes. Rx Weight_I  Real elements of the vector used during Receive to control ACC spatial pattern. This data is returned as a result of any of the calibration modes. Rx Weight_Q  Imaginary elements of the vector used during Receive to control ACC spatial pattern. This data is returned as a result of any of the calibration modes.    Layer 2 - Carrier Data  Field Name Values Description Sub Carrier Number / Sub Carrier 1-2, 3-4, 5-6, 7-8, 9-10 These two fields identify the 10 subcarriers. You can click on the pair of subcarriers to be enabled for this BTS. Subcarriers are assigned in pairs. Access Channel Checkmark or blank Access Code Channels:  The ACC Channel occupies the Code Channel with Walsh Index 0 configured on a specified subcarrier frequency. Each checkbox indicates which pair of subcarriers contains an Access Channel. Broadcast Channel Checkmark or blank Broadcast Code Channel (BCC):  If the box is checked, then a BCC will be transmitted in each pair of subcarriers that already contains an ACC.  The BCCs are used to broadcast software upgrades to the Modems. TDD Symmetry Ratio Symmetric or Asymmetric Symmetric Ratio is 1:1. Asymmetric Ratio is 1:3. This parameter determines the variable uplink and downlink ratio in a TDD frame. If set to Asymmetric, the downlink will have 3 times more bandwidth than the uplink. This is sometimes desired due to the types of users on the system, i.e., downloading files off the Internet. Repeat Uplink Pkts Checkmark or blank If the box is checked, the Modems will repeat uplink packets. Frequency (Scroll Bar) 2.305 GHz - 2.359 GHz  2.40 GHz - 2.473 GHz  2.50 GHz - 2.595 GHz  2.602 - 2.686 GHz Indicates the center frequency of the BTS transmit signal.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 230                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 Layer 2 - Bandwidth  Field Name Values Description Underload Threshold (%) 80% The threshold crossing in which a BTS changes its load congestion state from Overload (either Positive Access Overload or Negative Access Overload) to Underload.  Overload Threshold (%) 85% The threshold crossing in which a BTS changes its load congestion state from Underload to Positive Access Overload.  Positive Access Overload Threshold (%) 90% The threshold crossing in which a BTS changes its load congestion state from Negative Access Overload to Positive Access Overload.  Negative Access Overload Threshold (%) 95% The threshold crossing in which a BTS changes its load congestion state from either Underload or Positive Access Overload.  Reserved Channels for Accesses 12 Number of channels reserved for access when in the Underload state. CPE Inactive Time (min) 15 When a CPE has not communicated with a BTS for the set Inactive Time, the status of the CPE changes from active to inactive, as expressed in minutes. Bandwidth Adjust Interval (10ms) 20 A user’s bandwidth (uplink or downlink) is adjusted every Adjust Time if needed when on TCC. Expressed in units of 10 milliseconds. Realtime Session Hold Time (10ms) 250 The length of time a user with realtime data holds RF resources after the incoming packet queue is empty. Expressed in units of 10 milliseconds. Non-realtime Session Hold Time (10ms) 250 The length of time a user with non-realtime data holds RF resources after the incoming packet queue is empty. Expressed in units of 10 milliseconds. Non RT PreRelease BW (Kbps) 0 - 2,048 Default is 32 The bandwidth a user is assigned while in Non-realtime Session Hold Time. The Non RT PreRelease BW is in units of MAC packets. Denied Req Number 5 The number of consecutive times a user’s access request fails due to lack of RF resources before access is denied. Average LCC Q LEN Factor 2 Factor used to determine the average LLC queue length. Exponential For Average 1 Average exponent for all statistical variables but power. Average Burst Time (ms) 50 Average time for a data burst, expressed in units of 10 milliseconds. Max Bts Power (TCC Power) 320 Maximum RF power a BTS has. It is in units of maximum TCC power per channel. This field is not configurable. DL ACC Power Per Channel (TCC Power) 8 Downlink ACC RF power per channel. It is expressed in units of maximum TCC power per channel. TCC Initial Setup Power (%) 25% Initial setup power of a TCC channel. Expressed in units of the percentage of the max. TCC power per channel. Average Exponential Factor 1 Average exponent for average power. TCC Power per Channel Range (dB) 19 Number of decibels the downlink TCC power per channel can vary. Min Realtime Data Bandwidth (Kbps) 0 - 2,048 Default is 32 The minimum bandwidth a user with realtime data holds that is not used for acknowledgement. Expressed in units of MAC packets (data rate). continued…
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            231 October 23, 2003  Field Name Values Description Supported Modulations QAM4 QAM4  QAM8 QAM4  QAM16 QAM4 QAM8 QAM16 The highest QAM Rank the BTS can process. Total Priority Level Num. 8 The total number of QoS classes the BTS can maintain. Each class is associated with a priority. Max Bandwidth for Priority 1-8 (%) 1 default  85% 2 default  10%  3 default  5% 4-8 default  0% The percentage of the total bandwidth a QoS class associated with a certain priority is entitled to.    Layer 2 - WAN Congestion Control  Field Name Values Description Average Queue Size Weight (%) 100.0 For downlink, this value - expressed as a percentage - indicates how much the current queue size contributes to the calculation of the average queue size. The average queue size is used by the BTS Resource Management software to determine how many Code Channels to give a CPE. The greater the weight, the greater influence the current queue size has on the average queue size. The lower the weight, the more the queue size is an actual average of the current queue size over time. Max Queue Size (KB) 512 For downlink, the maximum queue size - in kilobytes - for each priority queue (high, low, voice). Once the queue is full (at Min Drop Threshold) all packets are dropped.  Min to Max Drop Probability (%) 10 For downlink, the probability of a packet being dropped when the Min Threshold has been reached. The higher this number, the more likely a packet will be dropped between the Min Threshold and the Max Threshold.  NOTE: All packets are dropped at the Max Threshold. Realtime Min Drop Threshold (%) 100 For downlink, the minimum queue size in which voice priority packets are considered for being dropped. For example, if set to 10%, once the queue size reaches 11% or more, voice priority packets may be dropped. The Max Drop Probability field determines if a packet is dropped once the Min Threshold is exceeded. High Priority Min Drop Threshold (%) 100 For downlink, the minimum queue size in which high priority packets are considered for being dropped. For example, if set to 10%, once the queue size reaches 11% or more, high priority packets may be dropped. The Max Drop Probability field determines if a packet is dropped once the Min Threshold is exceeded. Low Priority Min Drop Threshold (%) 100 For downlink, the minimum queue size in which low priority packets are considered for being dropped. For example, if set to 10%, once the queue size reaches 11% or more, high priority packets may be dropped. The Max Drop Probability field determines if a packet is dropped once the Min Threshold is exceeded.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 232                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Layer 2 - CPE Uplink Congestion Control  Field Name Values Description Avg Queue Size Weight (%) 100.0 For the uplink, this value - expressed as a percentage - indicates how much the current queue size contributes to the calculation of average queue size. The average queue size is used by the BTS Resource Management software to determine how many Code Channels to give a CPE. The greater the weight, the greater influence the current queue size has on the average queue size. The lower the weight, the more the average queue size is an actual average of the current queue size over time. Max Queue Size (KB) 512 For the uplink, the maximum queue size for each priority queue (high, low, voice). Once the queue is full (at Min Drop Threshold) all packets are dropped. Min to Max Drop Probability (%) 10 For the uplink, the probability of a packet being dropped when the Min threshold has been reached. The higher this number, the more likely a packet will be dropped between the Min Threshold and Max Threshold. Note: All packets are dropped at the Max Threshold. Realtime Min Drop Threshold (%) 100 For the uplink, the minimum queue size in which voice priority packets are considered for being dropped. For example, if set to 10% once the queue size reaches 11% or more, voice priority packets may be dropped. The Max Drop Probability field determines if a packet is dropped once the Min Threshold is exceeded. High Priority Min Drop Threshold (%) 100 For the uplink, the minimum queue size in which high priority packets are considered for being dropped. For example, if set to 10% once the queue size reaches 11% or more, high priority packets may be dropped. The Max Drop Probability field determines if a packet is dropped once the Min Threshold is exceeded. Low Priority Min Drop Threshold (%) 100 For the uplink, the minimum queue size in which low priority packets are considered for being dropped. For example, if set to 10% once the queue size reaches 11% or more, low priority packets may be dropped. The Max Drop Probability field determines if a packet is dropped once the Min Threshold is exceeded.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            233 October 23, 2003 Backhaul Interface Parameters  T1  Field Name Values Description Admin Status Up Up or Down. Display only. The administrative (operational) status of this T1. If Down, no traffic is able to go through this interface. This field is not configurable. Line Type ESF or D4 Framing format Send Code Send line code, Send No Code, Send Payload Code, Send Reset Code Selection of codes used for far-end loopback tests Signal Mode None Always None Line Length (foot) 5000 Length of T1 cables from BTS to terminating equipment Fdl None, Att54016, AnsiT1403 Facility Data Link (FDL) signaling type Line Status Change Trap Enabled or Disabled Enables generation of traps based on changes to the line status Line Index 1 The ATM IF index that this T1 is associated with Line Coding B8ZS or AMI Type of coding used to encode bits on the line Circuit Identifier  Vendor’s transmission circuit identifier Transmit Clock Source Loop timing or Local Timing Source of the framer Transmit clock Channelization Disabled Always Disabled (clear channel)   IMA Groups  Field Name Values Description Admin Status Up Up or Down. This is the administration (operational) status of the IMA group. If Down, no traffic is able to go through this interface. Symmetry Symmetric operation, Symmetric & Asymmetric, or Asymmetric Three options for the relationship of the Transmit and Receive link throughput:  ?? Symmetric operation - all links should be configured in both directions. Tx and Rx must both be active to use the disk. ?? Symmetric and Asymmetric operation - all links should be configured in both directions. Transmitting is allowed when Tx is active and Rx is not active. ?? Asymmetric operation - not required to configure the IMA links in both Tx and Rx directions. Min Num Rx Links 3 Minimum number of active Receive links that is necessary for the IMA group to be active. Tx Ima Id 0 Near-end (Transmit) IMA ID. continued…
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 234                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Field Name Values Description Alpha Value 2 Used to specify the number of consecutive valid ICP cells to be detected before moving to the IMA hunt state from the IMA sync state. Gamma Value 1 Used to specify the number of consecutive valid ICP cells to be detected before moving to the IMA sync state from the IMA pre-sync state. Index IMA group 2 IMA Group 1 or 2. Unique sequence number of the IMA group. Min Num Tx Links 1 Minimum number of Transmission links that have to be active for the IMA group to be active. Ne Tx Clk Mode ITC Near-end Transmit clock mode. Tx Frame Length M128 Length of IMA frame being transmitted. It is defined as M consecutive cells. Beta Value 2 Used to specify the number of consecutive ICP cells with errors to be detected before moving to the IMA hunt state from the IMA sync state.    Add T1s to IMA Groups  IMA Group T1s Associated With this IMA Group Notes IMA 1   IMA 2      ATM  Field Name Values Description If Index T1-1 (first T1 ID) Interface (IF) Index associated with this ATM interface. Max Vccs 1001 Maximum Virtual Channel Circuits for this interface. Max Active Vci Bits 9 The number of bits for Virtual Channel Identifier (VCI). Determines the maximum VCI value allowed for this interface. The Max Value is calculated by 2^ (max active vci bits). Max Vpcs 0 Maximum Virtual Private Circuits for this interface. Max Active Vpi Bits 3 The number of bits for Virtual Private Identifier. Determines the maximum VPI value allowed for this interface. The max value is calculated by  2^ (max active vpi bits).
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            235 October 23, 2003  PVC  Field Name Values Description if Index T1-1 The ATM IF index that this PVC is associated with. Vpi (start and end) 0 Virtual Path Identifier. The VPI + VCI are in the cell header and identify the next destination of a cell as it passes through a series of ATM switches. Vci (start and end) 0 Virtual Channel Identifier. The VPI + VCI are in the cell header and identify the next destination of a cell as it passes through a series of ATM switches. Tr/Re Traffic Descr Indexes 2 Index of the ATM Descriptor that applies to this PVC. The Transmit and Receive Descriptors are the same. AAL5 CPCS Tx SDU Size (Byte) 1528 The maximum AAL5 CPCS SDU size, in bytes, that is supported in the Transmit direction. AAL5 CPCS Rx SDU Size (Byte) 1528 The maximum AAL5 CPCS SDU size, in bytes, that is supported in the Receive direction. Admin Status Up Up or Down. The administrative (operational) state of the PVC. If it is Down, this PVC may not be used for traffic. AAL Type AAL5 (1-5) The type of ATM Adaptation Layer (AAL) used on this PVC: AAL1, AAL2, AAL3, AAL4, or AAL5. AAL5 Encap Type LLC encapsulation The type of data encapsulation used over the AAL5 SSCS layer. Cast Type P2P The connection topology type. Conn Kind PVC The type of VCL. This is always PVC.    Assign CPE to PVC  Field Name Values Description PVC T1-1-1-100 (example) Identifies the PVC to be assigned to the specified CPE. CPE 0 CPE assigned to specified PVC. Data  Denotes what type of PVC to assign.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 236                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 Global Parameters Configuration Form  Company:__________________________________________________________ Your Name:______________________________________Date:______________  NOTE 1: Field Values in gray rows indicate data that ordinarily should not be changed or that is populated automatically by the system.  NOTE 2: Default Field Values are underlined.  ATM Descriptor  Field Name Values Description Index 0 Identifier for this ATM Descriptor Type NOCLPNOSCR, NOCLPSCR, CLPNOTAGGINGSCR, CLPTAGGINGSCR, CLPNOTAGGINGMCR, CLPTRANSPARENTNOSCR, CLPTRANSPARENTSCR, NOCLPTAGGINGNOSCR Type of ATM Category CBR, RTVBR, NRTVBR, ABR, UBR Category of this ATM (see parameters, below) Frame Discard True True or False. If set to True, enables the ability to discard ATM frames. Param1 - Param5 0 Described below CBR Parameters:      PCR    Peak Cell Rate RTVBR Parameters:      PCR      SCR      MBS    Peak Cell Rate Sustainable Cell Rate Maximum Burst Size NRTVBR Parameters:      PCR      SCR      MBS    Peak Cell Rate Sustainable Cell Rate Maximum Burst Size ABR Parameters:      PCR      MCR      ICR      RDF      RIF      CDF    Peak Cell Rate Minimum Cell Rate Initial Cell Rate Rate Decrease Factor Rate Increase Factor Cutoff Decrease Factor UBR Parameters:      PCR    Peak Cell Rate
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            237 October 23, 2003 CPE Descriptor  Field Name Values Description Name  Name given to this CPE Descriptor. Index 1  (1-8) Unique index identifier for this CPE Descriptor. Priority 0 The priority that a CPE with this assigned Descriptor will receive from the BTS Resource Manager software when requesting RF resources. This field maps to the Layer 2 > Bandwidth Data component in the BTS. UL Max Bandwidth (Kbps) 0, 32, 64, 96, 128, 160, 192, 224, etc. Maximum uplink bandwidth allowable for a CPE with this Descriptor. The maximum number of code channels allocated for a CPE is directly related to this field. UL Min Bandwidth (Kbps) 0, 32, 64, 96, 128, 160, 192, 224, etc. Minimum uplink bandwidth allowable for a CPE. This field determines the number of code channels allocated when a CPE begins a data session. The larger this value, the more code channels allocated at session startup. DL Max Bandwidth (Kbps) 0, 32, 64, 96, 128, 160, 192, 224, etc. Maximum downlink bandwidth allowable for a CPE.  The maximum number of code channels allocated for a CPE is directly related to this field. DL Min Bandwidth (Kbps) 0, 32, 64, 96, 128, 160, 192, 224, etc. Minimum downlink bandwidth allowable for a CPE. This field determines the number of code channels allocated when a CPE begins a data session. The larger this value, the more code channels allocated at session startup. Avg Queue Size Weight (%) 100.0 How much the current queue size contributes to the calculation of average queue size. The average queue size is used by the BTS Resource Manager to determine how many resources (code channels) to give a CPE. The greater the weight, the greater influence the current queue size has on the average queue size. The lower the weight, the more the average queue size is an actual average of the current queue size over time. Max Queue Size (KB) 512 Maximum queue size for each priority queue (high, low, voice).  Once full (Max Threshold) all packets are dropped. Min to Max Drop Probability (%) 10 The probability of a packet being dropped when the Min Threshold has been reached. The higher this number, the more likely a packet will be dropped between the Min and Max Threshold. All packets are dropped at Max Threshold. Realtime Min Drop Threshold (%) 100 The minimum queue size at which voice-priority packets are considered for being dropped. For example, if set to 10% once the queue size reaches 11% or more, voice priority packets may be dropped. The Max Threshold Probability field determines if a packet is dropped once the Min Threshold is exceeded. High Priority Min Drop Threshold (%)  100 The minimum queue size at which high-priority packets are considered for being dropped. For example, if set to 10%, once the queue size reaches 11% or more, high priority packets may be dropped. The Max Threshold Probability field determines if a packet is dropped once the Min Threshold is exceeded. continued…
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 238                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Field Name Values Description Low Priority Min Drop Threshold (%) 100 The minimum queue size at which low-priority packets are considered for being dropped. For example, if set to 10%, once the queue size reaches 11% or more, low priority packets may be dropped. The Max Threshold Probability field determines if a packet is dropped once the Min Threshold is exceeded.    DiffServ  Field Name Values Description Code Point 0 Unique index (bit) to be mapped to a defined Differentiated Service. The code point is structured as follows:          0   1   2   3   4   5   6   7       +---+---+---+---+---+---+---+---+       |         DSCP          |  CU   |       +---+---+---+---+---+---+---+---+  DSCP: Differentiated Services Code Point CU:   Currently Unused  The Type of Service (ToS) bits are included in the DSCP. Priority Low, High, Voice Low, High, or Voice. This is the priority given to data packets associated with this Code Point/Service. The BTS processes data packets with Voice, then High priority before Low priority packets.    DHCP Relay  Field Name Values Description Relay Config Enabled (Checkbox) Enable or Disable. Clicking on the checkbox enables the DHCP Relay feature.  Free Address Low Agent Threshold 80   Free Address High Agent Threshold 100   Relay Config MaxDhcp Size 1488  Option 82 Tagging (Checkbox) Enable or Disable. Clicking on the checkbox enables the inclusion of one or more of the following Relay Information sub-options. Remote Id (Checkbox) If checked (enabled), include the Modem EID as the Remote ID Relay Information sub-option. It will be formatted as a 6 octet string “0000<EID>”. This format is often used in cable modem scenarios. continued…
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            239 October 23, 2003  Field Name Values Description Circuit Id (Checkbox) If checked (enabled), include the BTS ID as the Circuit ID Relay Information sub-option. It will be formatted as a 4-octet string “<BTS ID>”. This format is often used in cable modem scenarios. VPN Id (Checkbox) If checked (enabled), include the Modem EID as the VPN ID Relay Information sub-option. It will be formatted as a text string “navini<EID>”. This format is often used in DSL scenarios. Subnet Selection/Addr (Checkbox) If checked (enabled), include the specified Subnet Address as the Subnet Selection Relay Information sub-option. DOCSIS Device/Class (Checkbox) If checked (enabled), include the specified DOCSIS Device Class as the DOCSIS Device Relay Information sub-option.    ARP Proxy  Field Name Values Description ARP Ingress Proxy (Checkbox) If clicked, this enables the BTS to respond to ARP messages coming from the CPEs/Modems to the BTS.  ARP Egress Proxy (Checkbox) If clicked, this enables the BTS to respond to ARP messages coming from the network (backhaul) to the BTS on behalf of the CPEs/Modems.    Layer 3 Filter  Field Name Values Description Dynamic Acl (Checkbox) If clicked, this enables the Dynamic Access Control List. It provides the filtering rules for DHCP Relay - where a BTS configured with these capabilities may add learned addresses to the Modem’s Authenticated IP List (the Modem’s Ingress Filter). When BTSs and Modems are configured for this feature, any packet whose MAC address cannot be found in the current Modem’s Authenticated IP List will be discarded.  Egress Broadcast Filter (Checkbox) If clicked, this enables configured BTSs to drop all Ethernet Broadcast packets.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 240                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 CPE Configuration Data Form  Company:__________________________________________________________ Your Name:______________________________________Date:______________  NOTE 1: Field Values in gray rows indicate data that ordinarily should not be changed or that is populated automatically by the system. NOTE 2: Default Field Values are underlined.   Add CPE  Field Name Values Description EID (hex) 0 Equipment Identifier unique to each CPE. This value is determined during the manufacturing process and is displayed on the case of the CPE hardware, as well as entered and displayed as a hexadecimal number in this field. Descriptor Name CPE Descriptor-1 The name of the CPE Descriptor to be used with this CPE. The CPE Descriptor level affects Quality-of-Service (QoS) for this CPE’s data packets. Collect Perf Data True True or False. Collect Performance Data. If True, this CPE sends performance metrics to the BTS at the set interval. The BTS then uploads the performance data to the EMS at set intervals. The interval setting for collection and upload from the BTS to the EMS is set in the Performance fields for the BTS. Nomadic Disabled Enabled or Disabled. If Enabled, this CPE can access any BTS in the network that is defined in its Available Home BTS list at the bottom of the screen. When enabled, the Current Home BTS list is ignored. If disabled, this CPE can only access a BTS in its Available Home BTS list. Admin Status Active Active or Suspended. If suspended, the CPE cannot access any BTS. A Service Provider may decide to make the CPE suspended due to late service payments, security concerns, etc., rather than deleting the CPE from the system database.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            241 October 23, 2003 Home BTS  Field Name Values Description Available Home BTS  Add or Remove BTS Names. A list of available BTSs to include in the Current Home BTS list for this CPE. Current Home BTS  Add or Remove BTS Names. If Nomadic is disabled, these are the only BTSs this CPE can access. If Nomadic is enabled, this list is ignored.    Layer 3  Field Name Values Description Ingress Acl (Checkbox) If checkbox is clicked “on” any incoming packet whose MAC address cannot be found in the current CPE Authenticated IP List will be discarded. Ingress Broadcast (Checkbox) If checkbox is clicked “on” any incoming MAC broadcast message will be discarded.    DHCP Relay  Field Name Values Description Free Address High Drop Policy Drop most recently leased or Drop least recently leased Drop the most recently leased or least recently leased IP addresses Max Address Number Drop most recently leased or Drop least recently leased Drop the most recently leased or least recently leased IP addresses    IP Address  Field Name Values Description Static Client IP Address 0.0.0.0 Use static, rather than dynamic, IP addressing for this device. If static IP assignment is being made, add this IP address to the Ingress Filter Authenticated IP List. Otherwise, leave zeroes. Hardware Address 0:0:0:0:0:0 Enter the Ethernet address of the host computer to which the CPE is connected and that corresponds to the above Client IP Address.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 242                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            243 October 23, 2003    Appendix V:  Base Station Calibration Verification   Objective  The objective of this procedure is to verify the transmit power and noise figure of the Base Station using a Modem.   Test Equipment Required  ?? Installed Base Station, powered on and calibrated ?? Navini Drive Test Box ?? PC with Beamforming Display tool installed ?? 4 Fixed Attenuators:  two at 30 dB, two at 10 dB.  Low power attenuator acceptable. ?? RF cables and adaptors (3 ft or more) ?? N type Terminator for GPS    Test Procedure    Step 1. If not already done, calibrate the Base Station. Verify a successful calibration by monitoring the console with “caldebugon”. Verify that the cal error equals zero. If cal errors are not zero, troubleshoot the system before starting.   Step 2. Prepare the setup that is shown in Figure V1.  Step 3. Connect approximately 30-40 dB of attenuation to one end of the calibration cable. Connect a 3-6 ft RF cable to the other end of the attenuation. Connect 40 dB of attenuation to the end of that cable. Connect the attenuators to the Navini Drive Test box.  Step 4. Put the Drive Test box as far away from the Base Station as possible.  Terminate the GPS connector. Calculate the path loss from the Drive Test box to the Cal cable. In the EMS disable carriers 1-2, 3-4, and 9-10, leaving 5-6 and 7-8 enabled. Also verify that the ACC for 5-6 is selected.  This is found by clicking on the BTS tab, highlighting the specific BTS, then selecting Air Interface > Layer 2 > Carrier data. Refer to Figure V2.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 244                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 Figure V1:  Test Setup  NOTE: The EMS Client (CAM) and the Beamforming Display may be run from the same laptop    Figure V2:  Configure Carrier Data Window               Cal Cable –40 dBRFCablesAC powerBeamformingDisplayDrive Test ToolAttenuation-40 dBAttenuation-30 to -40 dBLaptop creatingtraffic throughFTP or pinging continuouslyGPS(not used)DC power (cigarette lighter)GPSantennaportInternetEMSServerEMS Client (CAM)A B C D EFGHIJKL2526 Cable and RFS performance2728 Cable Loss29 Cable Low Mid High Avg. loss30 1 -6.0 -6.0 -6.0 -6.031 2 -6.0 -6.0 -6.0 -6.032 3 -6.0 -6.0 -6.0 -6.033 4 -6.0 -6.0 -6.0 -6.034 5 -6.0 -6.0 -6.0 -6.035 6 -6.0 -6.0 -6.0 -6.036 7 -6.0 -6.0 -6.0 -6.037 8 -6.0 -6.0 -6.0 -6.038 cal -6.0 -6.0 -6.0 -6.0394041 Insertion loss thru cal cable and RFS42Cal path lossLNA gain43 Low Mid High Average (calculated) (calculated)441TX path-40.0-40.0-40.0-40.0-31.045 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.046 2TX path -40.0 -40.0 -40.0 -40.0 -31.047RX path-18.0-18.0-18.0-18.022.022.022.048 3TX path -40.0 -40.0 -40.0 -40.0 -31.049RX path-18.0-18.0-18.0-18.022.022.022.0504TX path-40.0-40.0-40.0-40.0-31.051 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.0525TX path-40.0-40.0-40.0-40.0-31.053 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.054 6TX path -40.0 -40.0 -40.0 -40.0 -31.055RX path-18.0-18.0-18.0-18.022.022.022.056 7TX path -40.0 -40.0 -40.0 -40.0 -31.057RX path-18.0-18.0-18.0-18.022.022.022.058 8TX path -40.0 -40.0 -40.0 -40.0 -31.059 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.060A B CDEFGHIJKLM6465 Receiver performance6667Power splitter loss UL Tcc Power UL SNRAbsolute Signal strength Noise Level Noise Figure RX Gain (DAC word)6869 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14570 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14571 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14572 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14573 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14574 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14575 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14576 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14577787980 Transmitter Performance8182 P out  Transceiver83Absolute Sync LevelPower (RMS)Power (peak)Power at antenna (RMS)Radiated power  (RMS)TX Gain (DAC word)8485 -80.0 36.0 45.49 30.0 48.0 20086 -80.0 36.0 45.49 30.0 48.0 20087 -80.0 36.0 45.49 30.0 48.0 20088 -80.0 36.0 45.49 30.0 48.0 20089 -80.0 36.0 45.49 30.0 48.0 20090 -80.0 36.0 45.49 30.0 48.0 20091 -80.0 36.0 45.49 30.0 48.0 20092 -80.0 36.0 45.49 30.0 48.0 2009394 Power deviation 0.0 0.0 0.0SpreadsheetSwitchTurn on one PAat a timeCal Cable –40 dBRFCablesAC powerBeamformingDisplayDrive Test ToolAttenuation-40 dBAttenuation-30 to -40 dBLaptop creatingtraffic throughFTP or pinging continuouslyGPS(not used)DC power (cigarette lighter)GPSantennaportInternetInternetEMSServerEMS Client (CAM)A B C D EFGHIJKL2526 Cable and RFS performance2728 Cable Loss29 Cable Low Mid High Avg. loss30 1 -6.0 -6.0 -6.0 -6.031 2 -6.0 -6.0 -6.0 -6.032 3 -6.0 -6.0 -6.0 -6.033 4 -6.0 -6.0 -6.0 -6.034 5 -6.0 -6.0 -6.0 -6.035 6 -6.0 -6.0 -6.0 -6.036 7 -6.0 -6.0 -6.0 -6.037 8 -6.0 -6.0 -6.0 -6.038 cal -6.0 -6.0 -6.0 -6.0394041 Insertion loss thru cal cable and RFS42Cal path lossLNA gain43 Low Mid High Average (calculated) (calculated)441TX path-40.0-40.0-40.0-40.0-31.045 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.046 2TX path -40.0 -40.0 -40.0 -40.0 -31.047RX path-18.0-18.0-18.0-18.022.022.022.048 3TX path -40.0 -40.0 -40.0 -40.0 -31.049RX path-18.0-18.0-18.0-18.022.022.022.0504TX path-40.0-40.0-40.0-40.0-31.051 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.0525TX path-40.0-40.0-40.0-40.0-31.053 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.054 6TX path -40.0 -40.0 -40.0 -40.0 -31.055RX path-18.0-18.0-18.0-18.022.022.022.056 7TX path -40.0 -40.0 -40.0 -40.0 -31.057RX path-18.0-18.0-18.0-18.022.022.022.058 8TX path -40.0 -40.0 -40.0 -40.0 -31.059 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.060A B CDEFGHIJKLM6465 Receiver performance6667Power splitter loss UL Tcc Power UL SNRAbsolute Signal strength Noise Level Noise Figure RX Gain (DAC word)6869 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14570 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14571 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14572 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14573 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14574 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14575 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14576 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14577787980 Transmitter Performance8182 P out  Transceiver83Absolute Sync LevelPower (RMS)Power (peak)Power at antenna (RMS)Radiated power  (RMS)TX Gain (DAC word)8485 -80.0 36.0 45.49 30.0 48.0 20086 -80.0 36.0 45.49 30.0 48.0 20087 -80.0 36.0 45.49 30.0 48.0 20088 -80.0 36.0 45.49 30.0 48.0 20089 -80.0 36.0 45.49 30.0 48.0 20090 -80.0 36.0 45.49 30.0 48.0 20091 -80.0 36.0 45.49 30.0 48.0 20092 -80.0 36.0 45.49 30.0 48.0 2009394 Power deviation 0.0 0.0 0.0A B C D EFGHIJKL2526 Cable and RFS performance2728 Cable Loss29 Cable Low Mid High Avg. loss30 1 -6.0 -6.0 -6.0 -6.031 2 -6.0 -6.0 -6.0 -6.032 3 -6.0 -6.0 -6.0 -6.033 4 -6.0 -6.0 -6.0 -6.034 5 -6.0 -6.0 -6.0 -6.035 6 -6.0 -6.0 -6.0 -6.036 7 -6.0 -6.0 -6.0 -6.037 8 -6.0 -6.0 -6.0 -6.038 cal -6.0 -6.0 -6.0 -6.0394041 Insertion loss thru cal cable and RFS42Cal path lossLNA gain43 Low Mid High Average (calculated) (calculated)441TX path-40.0-40.0-40.0-40.0-31.045 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.046 2TX path -40.0 -40.0 -40.0 -40.0 -31.047RX path-18.0-18.0-18.0-18.022.022.022.048 3TX path -40.0 -40.0 -40.0 -40.0 -31.049RX path-18.0-18.0-18.0-18.022.022.022.0504TX path-40.0-40.0-40.0-40.0-31.051 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.0525TX path-40.0-40.0-40.0-40.0-31.053 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.054 6TX path -40.0 -40.0 -40.0 -40.0 -31.055RX path-18.0-18.0-18.0-18.022.022.022.056 7TX path -40.0 -40.0 -40.0 -40.0 -31.057RX path-18.0-18.0-18.0-18.022.022.022.058 8TX path -40.0 -40.0 -40.0 -40.0 -31.059 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.060A B CDEFGHIJKLM6465 Receiver performance6667Power splitter loss UL Tcc Power UL SNRAbsolute Signal strength Noise Level Noise Figure RX Gain (DAC word)6869 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14570 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14571 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14572 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14573 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14574 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14575 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14576 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14577787980 Transmitter Performance8182 P out  Transceiver83Absolute Sync LevelPower (RMS)Power (peak)Power at antenna (RMS)Radiated power  (RMS)TX Gain (DAC word)8485 -80.0 36.0 45.49 30.0 48.0 20086 -80.0 36.0 45.49 30.0 48.0 20087 -80.0 36.0 45.49 30.0 48.0 20088 -80.0 36.0 45.49 30.0 48.0 20089 -80.0 36.0 45.49 30.0 48.0 20090 -80.0 36.0 45.49 30.0 48.0 20091 -80.0 36.0 45.49 30.0 48.0 20092 -80.0 36.0 45.49 30.0 48.0 2009394 Power deviation 0.0 0.0 0.0SpreadsheetSwitchTurn on one PAat a time
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            245 October 23, 2003 Step 5. Connect approximately 20-40 dB of attenuation to the end of the calibration cable. Connect a 3-6 ft RF cable to the other end of the attenuation. Connect the remaining attenuation to the end of that cable. Connect the attenuators to the Navini Drive Test box.  Step 6. Put the Drive Test box as far away from the Base Station as possible.  Terminate the GPS connector. Calculate the path loss from the Drive Test box to the Cal cable. In the EMS disable carriers 1-2, 3-4, and 9-10, leaving 5-6 and 7-8 enabled. Also verify that the ACC for 5-6 is selected.  This is found by clicking on the BTS tab, highlighting the specific BTS, then selecting Air Interface > Layer 2 > Carrier data. Refer to Figure V2.  Step 7. Disable all PAs except PA #1.  Step 8. From the Beamforming, verify that the Receive Sync from the Drive Test Tool is approximately  –80 dBm.  If not, adjust the value of the attenuators accordingly.  Step 9. Start an upload of a large file or ping continuously with packets 3,000 bytes or greater. You need to acquire at least 20 code channels in one sub-carrier. If the number of code channels is less than 20, start an additional ping sessions.   ping  <ip_address>  –l  3200  –t  Step 10. Capture the following parameters from the BTS Beam-forming display.  Refer to Figure V3: Downlink:  SYNC Recv Sgl Strength (dBm)      Uplink:  SNR (dB)      Uplink:  TCC Recv Sgl Strength (dBm)  Step 11. Capture the same parameters as in Step 10 for each of the remaining PAs, one by one.  That is, with PA #2  turned on and all other PAs turned off ; then with PA #3 turned on and all other PAs turned off; etc.  Step 12. Use the spreadsheet and input all the captured parameters to calculate the Tx power and Noise figure.  Step 13. Measure and record attenuation value.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 246                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 Figure V3:  BTS Beamforming Display Window     Other Parameters to Capture  The following parameters should also be captured:  ?? Calibration Sensitivity (set in EMS) ?? Path Loss (to be measured)  ?? Cal Cable Loss (set in EMS) ?? Power Splitter Loss (set in EMS)       SYNC Recv Sgl Strength (dBm)SYNC Recv Sgl Strength (dBm)Number of channels assigned to TCCNumber of channels assigned to TCCSNR (dB)TCC Recv Sgl Strength (dBm)SNR (dB)TCC Recv Sgl Strength (dBm)SYNC Recv Sgl Strength (dBm)SYNC Recv Sgl Strength (dBm)Number of channels assigned to TCCNumber of channels assigned to TCCSNR (dB)TCC Recv Sgl Strength (dBm)SNR (dB)TCC Recv Sgl Strength (dBm)
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            247 October 23, 2003 Results  Using the Base Station Calibration Verification form (Figure V4), submit your results to Navini Networks for evaluation and sign-off.  Figure V4:  Base Station Calibration Verification Form     A B C D EFGHI12General information Data input by user34Date 9/28/20035Site Name6BTS ID7Frequency (MHz)8Software release9Personnel101112 Cal cable loss-6.013 Attenuation70.014 Total Path loss-76.015 RX sensitivity (set in EMS)-90.016Antenna power (in EMS)30.017 Antenna gain18.0181920212223A B C D EFGHIJKL2526 Cable and RFS performance2728 Cable Loss29CableLowMidHighAvg. loss30 1 -6.0 -6.0 -6.0 -6.031 2 -6.0 -6.0 -6.0 -6.032 3 -6.0 -6.0 -6.0 -6.033 4 -6.0 -6.0 -6.0 -6.034 5 -6.0 -6.0 -6.0 -6.035 6 -6.0 -6.0 -6.0 -6.036 7 -6.0 -6.0 -6.0 -6.037 8 -6.0 -6.0 -6.0 -6.038 cal -6.0 -6.0 -6.0 -6.0394041 Insertion loss thru cal cable and RFS42 Cal path loss LNA gain43 Low Mid High Average (calculated) (calculated)44 1TX path -40.0 -40.0 -40.0 -40.0 -31.045RX path-18.0-18.0-18.0-18.022.022.022.0462TX path-40.0-40.0-40.0-40.0-31.047RX path-18.0-18.0-18.0-18.022.022.022.0483TX path-40.0-40.0-40.0-40.0-31.049 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.050 4TX path -40.0 -40.0 -40.0 -40.0 -31.051 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.0525TX path-40.0-40.0-40.0-40.0-31.053RX path-18.0-18.0-18.0-18.022.022.022.0546TX path-40.0-40.0-40.0-40.0-31.055 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.056 7TX path -40.0 -40.0 -40.0 -40.0 -31.057 RX path -18.0 -18.0 -18.0 -18.0 22.0 22.0 22.0588TX path-40.0-40.0-40.0-40.0-31.059RX path-18.0-18.0-18.0-18.022.022.022.060
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 248                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003     Test Form Instructions  These instructions explain how and what to enter into the Base Station Calibration Verification spreadsheet, as well as define each cell’s function. The cells that need an entry are shown in green on the spreadsheet. This document and form are to be used in conjunction with the Base Station Installation & commissioning Guide P/N 40-00047-00.  I.       Section 1: General Information A.    Date (D4) Excel will enter the current date. B.   SITE NAME (D5) Enter site name or customer designation. C.   BTS ID (D6) Enter BTS identification number or customer description. D.    Frequency (D7) Enter the system operating frequency that the customer has determined to use. E.   Software Release (D8) Enter the release number of the software load being used. F.    Name (D9) Enter your name. G.  Cal cable loss (D12) Excel will enter averaged value of calibration cable loss from cell E38. A B C D EFGHIJKLM6465 Receiver performance6667Power splitter lossUL Tcc Power UL SNRAbsolute Signal strengthNoise Level Noise Figure RX Gain (DAC word)6869 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14570 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14571 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14572 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14573 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14574 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14575 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14576 0.0316 -8.00 12.00 -114.05 -126.05 5.95 14577787980 Transmitter Performance8182 P out  Transceiver83 Absolute Sync Level Power (RMS) Power (peak)Power at antenna (RMS)Radiated power  (RMS)TX Gain (DAC word)8485 -80.0 36.0 45.49 30.0 48.0 20086 -80.0 36.0 45.49 30.0 48.0 20087 -80.0 36.0 45.49 30.0 48.0 20088 -80.0 36.0 45.49 30.0 48.0 20089 -80.0 36.0 45.49 30.0 48.0 20090 -80.0 36.0 45.49 30.0 48.0 20091 -80.0 36.0 45.49 30.0 48.0 20092 -80.0 36.0 45.49 30.0 48.0 2009394 Power deviation0.0 0.0 0.0
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            249 October 23, 2003 H.  Attenuation (D13) Enter the attenuation value inserted into calibration path. I.   Total Path loss (D14) Excel will enter the calculated value of the total path loss. J.   Receiver sensitivity (in EMS) (D15) Enter the same number entered in the EMS under Air Interface > Layer 1 > General tab > RX sensitivity. K.   Antenna power (in EMS) (D16) Enter the same number entered in the EMS under Air Interface > Layer 1 > General tab > Antenna power. L.   Antenna gain (D17) Enter gain value of antenna elements.  II.    Section 2: Cable and RFS performance A.   Cable loss (B30-D38) Enter the values measured during the cable sweeps. Include the minus sign on all entries. Include jumpers and surge protectors. B.   Insertion loss through cal cable and RFS (C44-E59) Enter values measured during the RF sweeps of the cables and the RFS. Include the minus sign for all entries. C.   Cal path loss (calculated) (H44-H58) Calculated value based on absolute loss measured during RF sweeps. The measured cable loss for antenna 1 plus 3dB for inherent loss in RFS (internal cables and LNA loss) is subtracted from the measured TX path loss to give absolute calibration path loss. It is important to check this value to ensure that it does not exceed –45 dB. D.   LNA gain (calculated) (J45-L59) Calculated value based on absolute loss measured during RF sweeps. The absolute value of the difference between TX path loss and RX path loss equals LNA gain for each antenna path.  III.  Section 3: Receiver Performance A.   Power splitter loss (in EMS) (A69-A76) Before calibrating, the script must have been run to enter the decimal values of the calibration board loss for each path. Enter those same values here. B.   UL TCC power (C69-C76) From Beamforming Display, enter the value from the "Tcc receive signal strength" field. There should be only one carrier active. This is the relative power per code channel, referenced to RX sensitivity, of that carrier, being received by the Base Station. C.   UL SNR (E69-E76) Enter the value from the Beamforming Display. This value can be found just above the TCC value in the same carrier column. D.   Absolute Signal strength (G69-G76) Calculated signal strength of the receive signal converted to 5 MHz BW. TCC power per code channel is converted to absolute by adding RX sensitivity and then subtracting spreading gain. Multiple antenna gain is then added to show receive
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 250                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 signal strength at each antenna. (RX sensitivity + UL TCC power - 10*LOG10(320) + 9). E.   Noise level (I69-I76) Calculated digital noise floor of the system measured in a 5 MHz BW. F.    Noise Figure (K69-K76) Calculated by adding the spreading gain of the individual carriers back in and subtracting the thermal noise floor (KTB) in a 500 KHz BW. G.    RX gain (DAC word) (M69-M76) The data word generated during calibration for the receiver gain DAC that controls the IF attenuator. It is found in the EMS under Air interface > Layer 1 > Show configuration > Antenna tab.  IV.  Section 4: Transmitter Performance A.   Analyzer Readings (A90-B97) 1.         Peak The peak amplitude of the sync signal measured on the spectrum analyzer. The measurement is taken with the spectrum analyzer in the time domain (0 Hz span) and RBW set for 5 MHz. Sweep time is typically between 10 and 20 ms. When taking the measurement, the sync signal will have peaks and valleys associated with it. Make sure to measure the absolute peak. 2.         RMS This is a calculated value based on measurements taken on several occasions, comparing peak power to RMS power on a Rhode & Schwartz spectrum analyzer. It has been determined that the correction factor for peak to average on a standard spectrum analyzer is 9.5 dB. This correction factor is the default entry in this section. If it is possible to make the RMS measurement with the proper equipment then that is the preferred method.  The calculation is very straightforward: peak power minus 9.5 dB = Power RMS. B.   P out transceiver (D90-E97) Power peak and Power RMS are calculated values using the value from the spectrum analyzer readings and the value entered for coupler/test cable loss (Cell H31). C.   Power at antenna (RMS) (G90-G97) Calculated value using the Output Power (Pout) of the transceivers and the Cable Loss plus the inherent loss of the RFS. D.   Radiated Power (RMS) (I90-I97) Calculated value using Power at the antenna and the value entered for antenna gain (Cell H32). E.   TX Gain (DAC word) The hex data generated during calibration for the transmit gain DAC that controls the IF attenuator. This is found in the EMS under Air interface > Layer 1 > Show configuration > Antenna tab. F.    Max power deviation across all antennae (E99, G99, I99) Calculated value showing the deviation between the lowest power antenna and the highest power antenna for each column.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            251 October 23, 2003   Appendix W:  Local Modem Tests   Objective  Local Wired Modem Testing (then Over-The-Air Modem Testing) will verify that the Base Station is working and able to transmit and receive data. Data rates are not being checked at this time. Refer to Figure W1 when setting up and performing the Wired Modem procedures.  Wired Modem Test  Equipment Required  ?? Modem    ?? PC - Laptop with CPE debug tool. Connect to CPE with an Ethernet cable ?? Attenuator - 70dB fixed attenuation, plus 40 adjustable range with 1dB resolution  (cascade multiple attenuators) ?? Shielding box - Need to provide 80 dB isolation. Shielding box may not be needed if   the Modem cannot sync to BTS over-the-air at the test location.   Figure W1:  Wired Modem Setup  CPEPCAttenuatorShielding boxBTSCalibration cableModemPCAttenuatorShielding boxBTSCalibration cableCPEPCAttenuatorShielding boxBTSCalibration cableModemPCAttenuatorShielding boxBTSCalibration cableModemPCAttenuatorShielding boxBTSCalibration cable
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 252                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Equipment Settings  Part of the Test Procedures below.  Test Procedure Setup  Set up the test procedures, per the following.  Step 1. Calibrate the BTS and perform the Calibration Verification procedure.  Connect the Modem and the attenuators. The combined attenuation should be set roughly as follows: Total attenuation = PTX - 30 + 18 – Cal cable loss + 80 Where PTX is the Tx output power at antenna input port that is set in EMS during calibration. Cal cable loss is the loss of the calibration cable.  The total attenuation should be partitioned between fixed and adjustable attenuators in such a way that the adjustable attenuator is set to about 10 dB.  Disconnect the calibration cable from the back of the BTS shelf and connect it to the attenuator as shown in the drawing Ping the BTS continuously from the Modem.  Check the sync level at the CPE debug tool. The level should be about –80 dBm.  Test Procedure - Check Modem Sensitivity & Output Power  Follow the steps in the procedure below.  Step 1. Record the downlink TCC power level and SNR reading on the CPE debug tool.  Step 2. Calculate the effective noise floor:  NF= SNRTCC – LevelTCC.  Where SNRTCC is the TCC SNR and LevelTCC is the received downlink TCC level.  NF should be close to –127 ±5. Step 3. Check Modem output power cap difference. It should be greater than 0. Step 4. Increase the attenuation by 10 dB (increase the attenuation of the adjustable attenuator). Step 5. Measure the effective noise floor and the output power cap difference gain. Step 6. Increase the attenuation by another 10 dB and take the measurements again (if the link is broken when the attenuation increases 10 dB, back off the attenuation by 10 dB and then increase the attenuation with 1 dB steps until the link is broken. Then reduce the attenuation by 4 dB).
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            253 October 23, 2003  Step 7. Calculate the maximum path allowed as follows: Max loss = Attenuation total + Cal cable loss + 30 Where Attenuation total is the total attenuation of all attenuators (fixed + adjustable).   Test Procedure - Check BTS Sensitivity (Individual Antenna)  Step 1. Set the attenuation of the attenuator so the total attenuation is about  PTX – 30 – Cal cable loss + 80. Step 2. Activate antenna #1 only. Step 3. Record the uplink TCC power level and SNR reading on the BTS debug tool.   Step 4. Calculate the effective noise floor: NF = SNRTCC  – LevelTCC.  Where SNRTCC is the TCC SNR and LevelTCC is the received downlink TCC level.  NF should be close to: SNR – BTS Sensitivity + 25 ±?5.  Where BTS sensitivity is the BTS sensitivity setting during calibration. Step 5. Record the Modem output power. Step 6. Increase the attenuation by 10 dB (increase the attenuation of the adjustable attenuator). Step 7. Measure BTS effective noise floor and Modem output power again. Step 8. Increase the attenuation by another 10 dB and take the measurements again (if the link is broken when the attenuation increases 10 dB, back off the attenuation by 10 dB and then increase the attenuation with 1 dB steps until the link is broken. Then reduce the attenuation by 4 dB. The same attenuation will be used for all antenna tests). Step 9. Calculate the maximum path allowed as follows: Max loss = Attenuation total + Cal cable loss + 30 Where Attenuation total is the total attenuation of all attenuators (fixed + adjustable).  Step 10. Repeat the steps for antennas 2 through 8. Step 11. Average the Modem output power over antennas 1 through 8 for each attenuation setting.   Test Procedure - Check BTS Sensitivity (Antenna Array)  Step 1. Set the initial attenuation the same as in the individual antenna testing procedure. Step 2. Activate all antennas. Step 3. Record the uplink TCC power level and SNR reading on BTS debug tool.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 254                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Step 4. Calculate the effective noise floor:  NF = SNRTCC – LevelTCC.  Where SNRTCC is the TCC SNR and LevelTCC is the received uplink TCC level.  NF should be close to SNR – BTS Sensitivity  + 25 ±?5.  Where BTS sensitivity is the BTS sensitivity setting during calibration. Step 5. Record the CPE output power. Step 6. Increase the attenuation by 10 dB (increase the attenuation of the adjustable attenuator). Step 7. Measure BTS effective noise floor and Modem output power again. Step 8. Increase the attenuation by the same amount as in individual antenna tests and measure the BTS effective noise floor and Modem output power.  Step 9. For each attenuation setting, the Modem output power should be 9 dB less compared to those (average) in individual antenna tests. Step 10. Increase the attenuation by another 18 dB. The link should be on. Step 11. Calculate the maximum path allowed as follows:  Max loss = Attenuation total  + Cal cable loss + 30  Where Attenuation total is the total attenuation of all attenuators (fixed + adjustable).   Test Procedure - Data Rate  Step 1. Set the attenuation of the attenuator so the total attenuation is about PTX – 30 +18 – Cal cable loss + 80. Step 2. Activate all antennas. Step 3. FTP a file with size greater than 10 Mbps from Modem to BTS (uplink). Step 4. Check the uplink data rate. It should be approximately 1 Mbps. Step 5. FTP a file with size greater than 20 Mbps from BTS to Modem (downlink). Step 6. Check the downlink data rate. It should be approximately 2 Mbps.  After the test is completed, reconnect the calibration cable back to the BTS and run the calibration. The new calibration table should be the same as before (the changes in Tx and Rx AGC should be within 2 bits).
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            255 October 23, 2003  Over-The-Air Modem Test  Equipment Required  Same as for Wired Modem Test.  Equipment Settings  Included in the Test Procedure.  Test Procedure  To set up a Modem for local over-the-air testing, follow the steps below.  Step 1. Connect a Modem to a test computer. Reference the Ripwave Modem User Guide, P/N 40-00026-00 for Modem setup procedures. The location of the test computer setup needs to be close to the Base Station, within its coverage range. Step 2. Ensure that the Modem is registered in the EMS. Refer to Ripwave Configuration Guide for Modem registration procedures.  Step 3. Using FTP software, transfer a 2 Mb file over-the-air from the test computer to the BTS. This is a system uplink transfer. Step 4. Using FTP software, transfer a 10 Mb file over-the-air from the BTS to the test computer. This is a system downlink transfer. Step 5. Ensure that both files transferred during testing.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 256                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            257 October 23, 2003    Appendix X:  Drive Study    Overview  The Drive Study is performed to confirm Base Station coverage. It is used to validate that the Base Station can be “seen” by a Modem throughout its predicted coverage area.   The RF coverage analysis displays areas of coverage from “good” to “bad” by the use of color-coding. An RF coverage analysis and its legend may be seen in Figure X1. The legend on the left displays the decibel strength for a given area, with red designating ‘good coverage’ and white designating ‘bad coverage’. The RF coverage analysis is used to map out the Drive Study route (Figure X2), along with geographic areas of concern. You should pay particular attention to null (white) areas and the cell edges.  Figure X1:  RF Coverage Analysis Example                       Good coverage area Medium coverage area Bad coverage areaGood coverage area Medium coverage area Bad coverage area
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 258                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Figure X2:  Drive Study Route Example                      Equipment Required  ?? Omni-directional antenna mounted outside vehicle ?? GPS with serial cable  ?? Modem ?? Ethernet Cable ?? Modem power supply ?? DC to AC power converter ?? Laptop computer ?? Drive Study Form <shown later in this section>   Drive Test Procedure  While driving you will collect statistics to validate the coverage plot. The application takes a reading every second and records the data in comma delimited file format. It is important to ensure that the GPS is on and that you can see the GPS coordinates in the application.   Since the Ripwave system is not a mobile system, do not exceed 10 mph during the Drive Study. Going any faster will negate the adaptive beamforming, as the vehicle will not be in the exact position calculated by the Base Station.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            259 October 23, 2003  Step 1. Ensure that the Base Station has successfully completed calibration and RF sanity measurements at the frequency and TX/RX signal levels that were determined during the site survey. Ensure that the Base Station is powered on and able to TX/RX data. Step 2. Create a CPE Descriptor, and assign it to the Modems to be used for the Drive Study:  CPE Descriptor Parameters Name:  Drive Study Index:  Next available number Priority:  1 UpLink Max Bandwidth:  64 UpLink Min Bandwidth:  32 DownLink Max Bandwidth:  96 DownLink Min Bandwidth:  64 Other parameters:  Use defaults.  Step 3. Mount an omni-directional antenna on the roof of the vehicle. This will serve as the antenna for the Modem. Step 4. Bring the RF cable from the omni-directional antenna into the vehicle through the window. Attach the antenna to the antenna input of the Modem. The rotating upright antenna on the Modem needs to be removed to perform this step. You will also need to disconnect the patch antennas inside (Figure X3).  Figure X3:  Patch Antennas  <TO BE PROVIDED AT A LATER DATE>
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 260                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  Step 5. Connect the DC to AC power converter to the power port in the vehicle. Step 6. If applicable, place the external antenna on the top of the vehicle. Step 7. Connect the Modem power supply to the Modem and to the DC to AC power converter. Step 8. Connect the Ethernet cable to the Ethernet port on the laptop computer and to the Ethernet port on the Modem. Step 9. Connect the GPS to the serial port on the laptop computer. Step 10. Optional:  Connect the laptop power supply to the DC to AC power converter. (The laptop can be run off of its battery.) Step 11. Power on the GPS and the laptop computer. Step 12. On the laptop computer, start the Navini Networks Drive Study application. Step 13. Verify that the GPS location (latitude and longitude) and the GPS time are seen in the application. Step 14. Power on the Modem.  Step 15. Enter a memo into the log file comment field of the Constellation Debugger about the route of the Drive Study being performed. When finished, click the log comment button. Step 16. Start driving along the Drive Study route determined during the RF coverage analysis. Do not exceed 10 - 15 mph. Step 17. When testing is completed, prepare the file(s) to be sent back to Navini for post-processing and analysis.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            261 October 23, 2003  Drive Study Form   Drive test area nameDate of Drive TestDrive Tester NameStandard Vehicle Name and TypeCPE EIDFrequency Band (ISM, MMDS)CPE test device RF cable loss (dB) CPE Test device Antenna gain (calibrated)Drive Route (Map attached)Drive test file nameBTS Transmit PowerBTS IDBTS antenna heightBTS antenna Omni/PatchMounted on the top or sideAntenna AzimuthAntenna downtiltDrive Test Route PlanYes / No Typical Clutter HeightHigh Density Urban CoveredCommercial/IndustrialResidential with TreesResidential with Few TreesPaved AreasGrass/AgricultureOpen AreaForested AreasWaterAirportsOthersThings to pay attention to:1. Make sure that the GPS data on the constellation debugger is updating all the time during the drive test.2. Make sure that the antenna only selects the omni port all the time.3. Make sure that the CPE is locked to the correct BTS by checking the BTS ID and frequency.4. Make sure that the RF connections are good all the time. Check this by observing the stability of the RF signal strength in the LOS loca..5. Please make proper log information in certain important locations.Fill the site configurationNavini Networks Drive Test  Check listSpecify the following items before the drive test
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 262                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            263 October 23, 2003    Appendix Y:  Location (FTP) Tests    Introduction  The Location, or FTP, Test is performed to check the Ripwave system operation through file transfers between the Base Station and the Modem.  The test measures the data rate performance at various locations within the coverage area. Data throughput is measured by executing file transfers using the FTP protocol for both upstream and downstream links. A file server must be in place on the same subnet with the BTS to accurately perform the file transfer, and the CPE User computer must be loaded with an FTP Client. As the file transfer is running, a data file is captured by the Modem tool. Data rates are captured by the FTP program.   Data is recorded in a spreadsheet format. The spreadsheet lists the location, GPS, and other information. As data rates are captured, the results are entered manually. An average SNR and sync RSSI can be read from the debug tool, and recorded, for quick comparison to the acceptable criteria (see “Acceptable Criteria” section of this appendix). For NLOS indoor locations, tests are performed both outside the building and inside, so that the obstruction loss for the building can be determined. Unless the customer can provide indoor access, all results will be LOS or Near NLOS.    Planning the Locations  Before the actual testing is conducted, you will need to select the locations for the testing to occur. The sites should meet specific criteria and include a mixture of the following environments:  ?? High Power (A), low clutter; close in, residential ?? High Power (A), high clutter; close in, commercial ?? Medium Power (B), low clutter; mid-range, residential ?? Medium Power (B), high clutter; mid-range, commercial ?? Low Power (C), low clutter; distant, residential ?? Lower Power (C), high clutter; distant, commercial  Where:  (A) High Power =  Sync Value greater than –70 dBm  (B) Medium Power =  Sync Value between –70 dBm and –85 dBm  (C) Low Power =  Sync Value between –85 dBm, and –95 dBm
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 264                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  At least 5 test points for each type are attempted. This may be difficult, depending upon the actual deployment scenario. Results may yield a very large percentage in one of the categories. For selecting an even spread across a 120-degree sector for a panel antenna installation, divide the 120 degrees into 6 even slices of 20 degrees each. Then divide each slice into 2 Km segments. This spaces each location at an approximate even distance throughout the complete sector and yields 36 test sites.  To select an even spread across a 360-degree cell for an omni antenna installation, divide the 360-degree cell into 12 even slices of 30 degrees each. Next, divide each slice into segments based on distance (1 Km or 2 Km, depending upon propagation). This will approximately space each location an even distance from each other throughout the complete cell, yielding approximately 48 test sites (based on a 4 Km cell radius). To do this, split the cell into 4 quadrants. Using the RF coverage analysis, select up to 16 locations per quadrant (Figure H1). Pay particular attention to null areas and the cell edges. At these locations you will perform a file transfer to measure the data rates available. The FTP/Location Test Tool program and the BTS Beamforming Display tool will be used to record RF parameters during each test. Figures Y1 and Y2 provide examples of simple guidelines for selecting an even spread across a cell area.  Figure Y1:  Example of a 3-sector Site
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            265 October 23, 2003  Figure Y2:  Example of 120° of an Omni Site    Acceptable Criteria  In order to evaluate the test results, several criteria are reviewed. These criteria are valid for both LOS and NLOS measurements.   ?? Processed Sync Signal Strength:  For a given test location, ± 2 dB variation during FTP ?? Absolute Sync Signal Strength – Processed Sync Signal Strength: not greater than 2 dB variation during FTP ?? SNR values consistent during the FTP for all carriers used: a.  QPSK:    at least 11 dB b.  8 PSK:    at least 14 dB c.  QAM16: at least 17 dB ?? UL and DL Packet Error Rates (PER) not greater than 1%. This will vary according to interference levels, but may not render the system inoperable. ?? Uplink Beamforming Gain: between 16 dB and 21 dB.  Perform a comparison of UL and DL, Beamforming Gain differences should be not greater than 3 dB.  ABC DEFA1A2A3A4A5A6ABC DEFA1A2A3A4A5A6ABC DEFA1A2A3A4A5A6
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 266                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  ?? Modem Transmit Power < 25 dBm; BTS Transmit Power < 0 dBm per code channel with power control  ?? Sync vs. Data Rate: Absolute Sync (dBm) UL Data Rate (Mbps)    DL Data Rate (Mbps)  (A) –55 to –70    0.6 to 1.0   1.5 to 2.0  (B) –70 to –85    0.5 to 1.0   1.2 to 2.0  (C) –85 to –95    0.10 to 0.5   0.3 to 1.0   Process  The recommended process for performing the Location (FTP) tests is described below.  First:  Verify that a single Modem transmits and receives data at expected rates, as indicated previously.  Second:  Verify that multiple Modems simultaneously transmit and receive data at acceptable rates, and the parameters listed above are being met. NOTE: The exact number of Modems is determined by field conditions. The minimum is two.  Third:  Verify operation at the full range of the system*. Include LOS Location Tests at cell edges. The height of Modem and uplink and downlink data rates are recorded for each site. Data rates are to be compared with expected results, as seen in the last item (Sync vs. Data Rate) of Acceptance Criteria. For example:  *2.6 GHz : ~12 Km *2.4 GHz: ~ 3 Km  Equipment Required  ?? Laptop computer ?? GPS with serial cable  ?? FTP/Location Test Tool application ?? BTS Beamforming diagnostic tool ?? Modem ?? Modem power supply ?? DC to AC power converter ?? Ethernet Cable
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            267 October 23, 2003  Location (FTP) Test Procedure  Two people are needed to perform this procedure. One will be in the car performing the location test, and the other will be at the Base Station checking the operation using the BTS Beamforming diagnostic tool.  1.  Ensure that the Base Station has successfully completed calibration, RF sanity measurements, and the Drive Study at the frequency and TX/RX signal levels that were determined by the cell site survey. Also ensure that the Base Station is powered on and is able to transmit and receive data. 2.  Connect the DC to AC power converter to the power port in the vehicle. 3.  Connect the Modem power supply to the CPE and to the DC to AC power converter. 4.  Connect the Ethernet cable to the Ethernet port on the laptop computer and to the Ethernet port on the Modem. 5.  Connect the GPS to the serial port on the laptop computer. 6.  Drive to one of the locations selected on the RF coverage analysis. Stop and turn off the vehicle.  7.  Power on the GPS, the Modem, and the laptop computer. Place the Modem on the roof of the vehicle. 8.  Start the Navini Networks FTP/Location Test Tool program. 9.  Verify that the Base Station is transmitting and that the Modem establishes sync and can communicate with the Base Station. Ping a device address on the network side of the Base Station, and verify that a reply is received. While monitoring the Constellation Debugger, position the Modem to reduce the difference between absolute sync and processed sync levels to 2 or less. 10. Enter a memo into the comment field about which link of the test is being performed. 11. Verify that the GPS input is seen in the application. 12. Put the location number/site identifier into the comment field of the Navini Networks Constellation Debugger, and press the Enter key. This will identify the site location.  13. On the EMS connected to the Base Station, start the BTS Beamforming diagnostic tool. 14. From the laptop computer with the Modem connected to it, start a downlink FTP file transfer. Record the results on the site page or in the log. 15. On the EMS connected to the Base Station, using the BTS Beamforming diagnostic tool verify the strength and direction of the beam during the file transfer. Record the results on the site page or in the log. 16. Repeat the file transfer three times, stopping and starting the Debugger and Beamforming tool for each transfer 17. Repeat steps 14-15, this time performing an uplink FTP transfer.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 268                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 18. When finished, remove the Modem from the roof and secure equipment for travel. 19. Drive to the next location selected on the RF coverage analysis. Stop, and turn off the vehicle. 20. Repeat steps 7 to 19 until all locations are tested. At this point send this data to the RF Engineers to analyze, or continue until each quadrant in the cell is complete. When you send the results depends upon the schedule or results from the file transfers.
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            269 October 23, 2003  Location (FTP) Test Form  The form for recording the Location (FTP) test results is an Excel spreadsheet. Shown in Table Y1, the actual column headers go across the top of the form, but are broken into two sections here for readability.  Table Y1:  Location (FTP) Test Form     BTS ID Sector Software ReleaseSite name File name; CPE File name; BTSDistance (Km) LOS NLOS CPECPE w/ extFTP Data Rate Downlink (Kbps)FTP Data Rate Uplink (Kbps)Absolute Sync (dB) Remarks0 0028800.10.20.30.40.50.60.70.80.9100.2 0.4 0.6 0.8 1distance Kmdata rate MbpsDownlinkUplink
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 270                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            271 October 23, 2003   Appendix  Z:  Site Installation Close-out Documentation   List of Documents  When performing a Ripwave Base Station installation, a number of tasks and forms are completed during the process. The following is a list and a brief description of each of the closing documents that are either required or optional for completing the Customer Acceptance of the system once it is commissioned. If the item is designated as REQUIRED it must be sent back to Navini Technical Services. If a required document cannot be obtained, you must retain approval in advance from the Manager, Navini Technical Services.   _____ 1.  Customer Contact List.  REQUIRED  (Project Manager & Customer) _____ 2.  Site Candidate Evaluation Form. REQUIRED  Drawings/pictures from site. _____ 3.  Drive Instructions & Map to location.  REQUIRED _____ 4.  Network Diagram.  Optional. _____ 5.  Antenna Power and Cable Selection REQUIRED _____ 6.  Bill of Materials (BoM).  REQUIRED  This is a list of the physical materials and their associated quantities that are used to build the site. This list includes but is not limited to RF cable type and size, RF cable connectors, grounding, racks, power supplies, RF cable hangers, RFS mounts, and so forth. _____ 7.  Excel Configuration Forms.  REQUIRED  These forms are created in Excel spreadsheets and used to plan the system configuration parameters that must be in place as part of the installation and commissioning of the system. The forms are filled out according to how the EMS, BTS, Modems, and Global Parameters are to be configured for this customer site. _____ 8.  RF Plot REQUIRED _____ 9.  Interference Data.  Optional. _____ 10.  Interference Analysis Report.  REQUIRED if Interfere Data Collected (RF Planning)  Above information is required before departing to site  _____ 11.  RFS System Test Form.  REQUIRED  This form contains the data that is captured during the RF sweeps on the Ripwave RFS antenna and RF cables. _____ 12.  Base Station Installation Certification Form.  REQUIRED  This form represents the close of a key milestone, the physical installation of the BTS and RFS. It includes RFS antenna height, azimuth, downtilt, grounding, weatherproofing, and other information about the site. _____ 13.  Export BTS Data.  REQUIRED  This is not a form that needs to be completed; rather, it is data that is captured from the EMS once the Base Station and Modems have been provisioned. This step should be completed prior to the Drive Study, and then again prior to the Location (FTP) tests.
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 272                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 _____ 14.  Export EMS Data.  REQUIRED _____ 15.  Export CpeDescriptors (all).  Optional. _____ 16.  Base Station Calibration Verification Form.  REQUIRED  Calibration Verification is sometimes referred to as the Sanity Test. The form contains the operational results of the Base Station transmit and receive tests after the physical installation has been completed and the BTS has been turned on.  _____ 17.  Drive Study Form & Data.  REQUIRED  Also referred to as Drive Test. The form contains results of driving the coverage area of the installed Base Station site and capturing sync data on a laptop. The information is provided to Navini Networks to help tune the RF coverage model. Need Data Constellation Display. _____ 18.  RF Plot Tuned Model.  REQUIRED _____ 19.  Location (FTP) Test Form.  REQUIRED  This form contains data rate information that is captured during RF throughput testing. The data is captured at both the EMS and at the Modem location on a laptop. The number of points to capture is determined by Navini Networks and the customer. Need BTS Beamforming and Constellation Display. _____ 20.  RMAs.  REQUIRED if replaced cards from original shipment _____ 21.  Backup of Customer Deployed EMS Server.  REQUIRED   List of Pictures  The following is a list and description of the REQUIRED pictures that Navini Networks recommends capturing during the installation project. Additional pictures are acceptable.  _____ 1.  RFS antenna mounted on the tower or rooftop  _____ 2.  Weatherproofed connectors on the back of the RFS antenna  _____ 3.  Cable Bend radius on the tower to the RFS  _____ 4.  Jumper cable to RF main feeder connections weatherproofed  _____ 5.  RF cable strap ground kit installation in all places as required for installation. RF main feeder runs.  _____ 6.  Lower buss bar with lightning protectors (weatherproofed if outside the shelter)  _____ 7.  Main feeder to BTS jumper connections  _____ 8.  BTS jumper connections to BTS  _____ 9.  RFS antenna grounding connections  _____ 10.  BTS grounding connections at BTS and buss bar  _____ 11.  Power connections to the BTS
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            273 October 23, 2003 _____ 12.  BTS split chassis cabling  _____ 13.  Ground connections to earth ground or building steel  _____ 14.  Tower or mount connections to ground   Checklist  This checklist should be completed and sent to Navini Networks along with the forms and data.   Closeout Documents Completed Date File Name 1. Customer Contact List   2. Site Candidate Evaluation Form completed       3. Drive Instructions & Map     4. Network Diagram (optional)     5. Antenna Power & Cable Selection     6. Bill of Materials               7. Excel Configuration Forms          8. RF Plot     9. Interference Data (optional)     10. Interference Analysis Report     11. RFS System Test Form       12. Base Station Installation Certification Form       13. Exported BTS Data       14. Exported EMS Data       15. Exported CPE Descriptor Data (optional)     16. Base Station Calibration Verification Form        17. Drive Study Form & Data       18. RF Plot Tuned Model     19. Location (FTP) Test Form       20. RMAs     21. Backup from EMS      Closeout Pictures Completed Date File Name 1. RFS mounted     2. Weatherproofed connectors on RFS       3. Cable Bend radius     4. Jumper cable to RF main feeder     5. Cable ground kits if needed       6. Shelter bus bar with lightning arrestors       7. Main feeder to BTS jumpers     8. BTS Jumpers to BTS       9. RFS grounded       10. BTS grounding at BTS/buss bar
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 274                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003 11. Power connected to BTS       12. Split chassis cabling         13. Ground connections to earth ground       14. Tower or mount connections to ground
Navini Networks, Inc.                      Ripwave Base Station I&C Guide Part #40-00047-00 Rev F v1.0 (TTA)            275 October 23, 2003    Appendix AA:  Customer Acceptance Form    Base Station Installation & Commissioning Services Customer Acceptance Form   Customer Name:             Customer’s Authorized Representative:           Job Title:              Office Address:             Email Address:              Office Phone:              Cell Phone or Pager:              Site Name:              Site Description:                      ________  Site Physical Address:                           INSTALLATION SECTION: Date Installation Started:        Completed:           ________           Customer Acceptance By: _____________________   Title: ________________Date:                                          __________  COMMISSIONING SECTION: Date Commissioning Started:       Completed:      _________               Customer Acceptance By: _____________________   Title: ________________Date:  ______________________________   TEST ACCEPTANCE SECTION: Date Testing Started:          Completed:                     Customer Acceptance By: _____________________   Title: ________________Date: ______________________________
Ripwave Base Station I&C Guide                      Navini Networks, Inc. 276                   Part #40-00047-00 Rev F v1.0 (TTA) October 23, 2003  This Customer Acceptance Form is subject to and governed by all of the terms and conditions set forth in the Master Supply Agreement between the parties.  The Customer acknowledges, understands and agrees that when it’s Authorized Representative signs-off the Test Acceptance Section of this Form, Customer has thoroughly inspected the installation and commissioning services, and Customer’s sign-off means that completion of on-site verification that the Equipment installed by Seller performs in accordance with the Acceptance Criteria set forth in the Master Supply Agreement between the parties.  The completed Navini Networks’ Site Installation and Commissioning Documents referenced below and attached hereto are incorporated by reference into this Customer Acceptance Form for all purposes.   Navini Networks Site Installation and Commissioning Documents (double-click on the box to check or de-select a checkmark when completing the form):   Site Candidate Evaluation Report   Site Materials BoM   Site Drawings   Site Construction Specific Tests, as required – Grounding System Test Results, Concrete Break Test Results, Tower Guy Tensioning Test Results, etc.   Site Specific Digital Photographs, as Required   RFS System Tests   Base Station Installation Certification   Base Station Calibration Verification   Location (FTP) Tests   Drive Studies   Coverage Predictions Maps   Soft Copies of Test Results, if Requested