CipherLab 1664 Bluetooth Barcode Scanner User Manual 1664 Scanner User Guide v1 00 E

CipherLab Co., Ltd. Bluetooth Barcode Scanner 1664 Scanner User Guide v1 00 E

manual

     1664 Bluetooth Barcode Scanner  Setup barcodes included.      Version 1.00
 Copyright © 2011 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law.  Reverse engineering of the software is prohibited. Due to continued product development this information may change without notice.  The information and intellectual property contained herein is confidential between CIPHERLAB and the client and remains the exclusive property of CIPHERLAB CO., LTD.  If you find any problems in the documentation, please report them to us in writing.  CIPHERLAB does not warrant that this document is error-free. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of CIPHERLAB CO., LTD. For product consultancy and technical support, please contact your local sales representative. Also, you may visit our web site for more information. The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD.  All brand, product and service, and trademark names are the property of their registered owners. The editorial use of these names is for identification as well as to the benefit of the owners, with no intention of infringement.   CIPHERLAB CO., LTD.  Website: http://www.cipherlab.com                 IMPORTANT NOTICES
 FOR USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FOR CANADA This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus," ICES-003 of Industry Canada. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le material brouilleur: "Appareils Numeriques," NMB-003 edictee par l'Industrie.
 FOR HAND-HELD PRODUCT WITH RF FUNCTIONS The 1664 unit (FCC ID: Q3N-1664) complies with FCC radiation exposure limits set forth for uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. The unit has very low level of RF energy that it is deemed to comply without testing of specific absorption ratio (SAR). The 3610 unit (FCC ID: Q3N-3610) complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & body. It only operated in hand-held used. If only transfer data to the host cordless, please keep the minimum distance 20 cm between machine & body. SAFETY PRECAUTIONS RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.  The use of any batteries or charging devices, which are not originally sold or manufactured by CipherLab, will void your warranty and may cause damage to human body or the product itself.  DO NOT disassemble, incinerate or short circuit the battery.  DO NOT expose the scanner or the battery to any flammable sources.  For green-environment issue, it's important that batteries should be recycled in a proper way.   Under no circumstances, internal components are self-serviceable. CARE & MAINTENANCE  Use a clean cloth to wipe dust off the scanning window and the body of the scanner as well as the charging device. DO NOT use/mix any bleach or cleaner.  If you want to put away the scanner for a period of time, download the collected data to a host computer when in the memory mode, and then take out the battery. Store the scanner and battery separately.   When the scanner resumes its work, make sure the battery is fully charged before use.  If you shall find the scanner malfunctioning, write down the specific scenario and consult your local sales representative.
 Version  Date  Notes 1.00  Nov. 30, 2011  Initial release               RELEASE NOTES
  CONTENTS IMPORTANT NOTICES ........................................................................................................................... - 2 - For USA ................................................................................................................................................. - 3 - For Canada ........................................................................................................................................... - 3 - For Hand-held Product with RF Functions ....................................................................................... - 4 - Safety Precautions .............................................................................................................................. - 4 - Care & Maintenance ........................................................................................................................... - 4 - RELEASE NOTES ................................................................................................................................... - 5 - INTRODUCTION ......................................................................................................................................... 1 Getting Familiarized with 1664 and 3610 ......................................................................................... 2 Installing the Battery to 1664 ......................................................................................................... 2 Charging the Battery ......................................................................................................................... 3 Charging the Battery via Charger .................................................................................................... 4 Using 3610 ......................................................................................................................................... 5 Inside the Package ................................................................................................................................. 6 Product Highlights ................................................................................................................................... 6 Symbologies Supported ......................................................................................................................... 7 QUICK START ............................................................................................................................................. 9 Enter Configuration Mode ................................................................................................................... 11 Exit Configuration Mode ...................................................................................................................... 11 Default Settings .................................................................................................................................... 12 Save User Settings as Defaults .................................................................................................... 12 Restore User Defaults .................................................................................................................... 12 Restore System Defaults ............................................................................................................... 12 Read a Setup Barcode ........................................................................................................................ 13 Configure Parameters .................................................................................................................... 13 List the Current Settings ................................................................................................................ 17 Create One-Scan Setup Barcodes ..................................................................................................... 19 UNDERSTANDING THE BARCODE SCANNER .......................................................................................  21 1.1 Battery ............................................................................................................................................ 21 1.1.1 How to Operate the Scanner .............................................................................................. 22 1.1.2 Auto Power Off & Power-Saving ........................................................................................ 23 1.2 Memory ........................................................................................................................................... 26 1.2.1 Transmit Buffer ..................................................................................................................... 26 1.2.2 Memory Mode ....................................................................................................................... 27 1.3 LED Indicator ................................................................................................................................. 29 1.3.1 Good Read LED ..................................................................................................................... 30 1.3.2 Good Read LED Duration .................................................................................................... 30 1.4 Beeper ............................................................................................................................................. 31 1.4.1 Beeper Volume ..................................................................................................................... 32
 1664 Barcode Scanner User Guide  1.4.2 Good Read Beep ................................................................................................................... 33 1.4.3 Low Battery Alarm ................................................................................................................ 34 1.5 Vibrator ........................................................................................................................................... 34 1.5.1 Good Read Vibrator .............................................................................................................. 34 1.5.2 Good Read Vibrator Duration ............................................................................................. 34 1.6 Send “NR” to Host ......................................................................................................................... 35 1.7 Scan Modes .................................................................................................................................... 36 1.7.1 Laser Mode ............................................................................................................................ 36 1.7.2 Auto Off Mode ....................................................................................................................... 37 1.7.3 Auto Power Off Mode ........................................................................................................... 37 1.7.4 Aiming Mode ......................................................................................................................... 38 1.7.5 Multi-Barcode Mode ............................................................................................................. 38 1.8 Scanning Timeout ......................................................................................................................... 39 1.9 Delay between Re-read ................................................................................................................ 40 1.10 Read Redundancy for All Symblogies ..................................................................................... 41 1.11 Addon Security for UPC/EAN Barcodes ................................................................................... 42 1.12 Negative Barcodes...................................................................................................................... 42 1.13 Using Direct USB Cable .............................................................................................................. 43 1.13.1 Direct USB Interface .......................................................................................................... 43 1.13.2 Disable Direct USB Interface ............................................................................................ 43 1.14 Picklist Mode ............................................................................................................................... 44 1.15 Pager Beep Duration .................................................................................................................. 44 1.16 Time Stamp ................................................................................................................................. 45 1.16.1 DATE AND TIME SETTINGS ............................................................................................... 45 1.16.2 SEPARATOR FOR DATE AND TIME .................................................................................. 47 1.16.3 DATE FORMAT .................................................................................................................... 48 1.17 2D Decode Setting ..................................................................................................................... 49 1.17.1 Aiming Pattern ................................................................................................................... 49 1.17.2 Decoding Illumination ....................................................................................................... 49 1.18 Hardware Reset .......................................................................................................................... 50 1.18.1 Restore System Defaults .................................................................................................. 50 1.18.2 Reset Connection ............................................................................................................... 50 SELECTING OUTPUT INTERFACE ........................................................................................................... 51 2.1 Bluetooth® HID .............................................................................................................................. 52 2.1.1 Activate Bluetooth® HID & Select Keyboard Type ........................................................... 53 2.1.2 Reset Connection ................................................................................................................. 54 2.1.3 Keyboard Settings ................................................................................................................ 55 2.1.4 Inter-Character Delay ........................................................................................................... 62 2.1.5 Inter-Function Delay ............................................................................................................. 62 2.1.6 HID Character Transmit Mode ............................................................................................ 63 2.1.7 Keypad Support for iPhone/iPad ....................................................................................... 63 2.2 Bluetooth® SPP Slave ................................................................................................................... 64 2.2.1 Activate Bluetooth® SPP Slave Mode ............................................................................... 64 2.2.2 Inter-Function Delay ............................................................................................................. 64 2.2.3 ACK/NAK Timeout ................................................................................................................ 65 2.3 Bluetooth® SPP Master ................................................................................................................ 66 2.3.1 Activate Bluetooth® SPP Master Mode ............................................................................. 66
 1664 Barcode Scanner User Guide   2.3.2 Inter-Function Delay ............................................................................................................. 68 2.3.3 ACK/NAK Timeout ................................................................................................................ 69 2.3.4 Switch between Master/Slave Mode ................................................................................ 69 2.4 USB HID via 3610 ......................................................................................................................... 70 2.4.1 Activate USB HID & Select Keyboard Type ....................................................................... 71 2.4.2 Keyboard Settings ................................................................................................................ 72 2.4.3 Inter-Character Delay ........................................................................................................... 79 2.4.4 Inter-Function Delay ............................................................................................................. 79 2.4.5 HID Character Transmit Mode ............................................................................................ 80 2.5 USB Virtual COM via 3610 ........................................................................................................... 81 2.5.1 Activate USB Virtual COM .................................................................................................... 81 2.5.2 Inter-Function Delay ............................................................................................................. 81 2.5.3 ACK/NAK Timeout ................................................................................................................ 82 2.6 Direct USB HID ............................................................................................................................... 83 2.6.1 Activate USB HID & Select Keyboard Type ....................................................................... 84 2.6.2 Keyboard Settings ................................................................................................................ 85 2.6.3 Inter-Character Delay ........................................................................................................... 92 2.6.4 Inter-Function Delay ............................................................................................................. 92 2.6.5 HID Character Transmit Mode ............................................................................................ 93 2.7 Direct USB Virtual COM ................................................................................................................ 94 2.7.1 Activate USB Virtual COM .................................................................................................... 94 2.7.2 Inter-Function Delay ............................................................................................................. 94 2.7.3 ACK/NAK Timeout ................................................................................................................ 95 SETTING UP A WPAN CONNECTION ...................................................................................................... 97 3.1 Connecting via 3610 .................................................................................................................... 98 3.1.1 Connect to 3610 ................................................................................................................... 98 3.1.2 Change Interface .................................................................................................................. 99 3.1.3 Configure Related Settings ............................................................................................... 100 3.2 Connecting via Bluetooth® Dongle ........................................................................................... 101 3.2.1 Change Interface ................................................................................................................ 101 3.2.2 Configure Related Settings ............................................................................................... 102 3.2.3 Connect to Dongle .............................................................................................................. 105 CHANGING SYMBOLOGY SETTINGS .................................................................................................... 113 4.1 Codabar ........................................................................................................................................ 114 4.1.1 Start/Stop Transmission ................................................................................................... 114 4.1.2 CLSI Conversion .................................................................................................................. 114 4.1.3 Code Length Qualification................................................................................................. 115 4.2 Code 25 – Industrial 25 ............................................................................................................. 116 4.2.1 Code Length Qualification................................................................................................. 117 4.3 Code 25 – Interleaved 25 .......................................................................................................... 118 4.3.1 Verify Check Digit ............................................................................................................... 118 4.3.2 Transmit Check Digit ......................................................................................................... 118 4.3.3 Convert to EAN-13 .............................................................................................................. 119 4.3.4 Code Length Qualification................................................................................................. 120 4.4 Code 25 – Matrix 25 ................................................................................................................... 121 4.4.1 Verify Check Digit ............................................................................................................... 121 4.4.2 Transmit Check Digit ......................................................................................................... 121 4.4.3 Code Length Qualification................................................................................................. 122 4.5 Code 25 – Chinese 25 ................................................................................................................ 123
 1664 Barcode Scanner User Guide  4.6 Italian Pharmacode (Code 32) .................................................................................................. 124 4.7 Code 39 ........................................................................................................................................ 125 4.7.1 Verify Check Digit ............................................................................................................... 125 4.7.2 Transmit Check Digit ......................................................................................................... 125 4.7.3 Standard/Full ASCII Code 39 ........................................................................................... 126 4.7.4 Code Length Qualification................................................................................................. 127 4.8 Trioptic Code 39 .......................................................................................................................... 128 4.9 Code 93 ........................................................................................................................................ 129 4.9.1 Code Length Qualification................................................................................................. 130 4.10 Code 128 ................................................................................................................................... 131 4.11 GS1-128 (EAN-128) .................................................................................................................. 132 4.11.1 Transmit Code ID ............................................................................................................. 132 4.11.2 Field Separator (GS Character) ...................................................................................... 132 4.12 ISBT 128 .................................................................................................................................... 133 4.12.1 ISBT Concatenation ......................................................................................................... 133 4.12.2 ISBT Concatenation Redundancy .................................................................................. 134 4.13 GS1 DataBar (RSS Family) ...................................................................................................... 135 4.13.1 Select Code ID .................................................................................................................. 135 4.13.2 GS1 DataBar Omnidirectional (RSS-14) ...................................................................... 136 4.13.3 GS1 DataBar Expanded (RSS Expanded) ..................................................................... 137 4.13.4 GS1 DataBar Limited (RSS Limited) ............................................................................. 138 4.13.5 Convert to UPC/EAN ........................................................................................................ 139 4.14 MSI .............................................................................................................................................. 140 4.14.1 Verify Check Digit ............................................................................................................. 140 4.14.2 Transmit Check Digit ....................................................................................................... 140 4.14.3 Code Length Qualification .............................................................................................. 141 4.15 EAN-8 .......................................................................................................................................... 142 4.16 EAN-13 ........................................................................................................................................ 143 4.16.1 Convert to ISBN ................................................................................................................ 144 4.16.2 Convert to ISSN ................................................................................................................ 144 4.17 UCC Coupon Extended Code ................................................................................................... 145 4.18 UPC-A .......................................................................................................................................... 146 4.18.1 Transmit System Number ............................................................................................... 147 4.18.2 Transmit Check Digit ....................................................................................................... 147 4.19 UPC-E .......................................................................................................................................... 148 4.19.1 Select System Number ................................................................................................... 149 4.19.2 Convert to UPC-A .............................................................................................................. 149 4.19.3 Transmit System Number ............................................................................................... 150 4.19.4 Transmit Check Digit ....................................................................................................... 150 4.20 Code 11 ...................................................................................................................................... 151 4.20.1 Verify Check Digit ............................................................................................................. 151 4.20.2 Transmit Check Digit ....................................................................................................... 151 4.20.3 Code Length Qualification .............................................................................................. 152 4.21 Composite Code ........................................................................................................................ 153 4.21.1 Composite CC-A/B ........................................................................................................... 153 4.21.2 Composite CC-C ................................................................................................................ 153 4.21.3 Composite TLC-39............................................................................................................ 153 4.21.4 UPC Composite Mode...................................................................................................... 154
 1664 Barcode Scanner User Guide   4.21.5 GS1-128 Emulation Mode for UCC/EAN Composite Codes ...................................... 154 4.22 US Postal Code .......................................................................................................................... 155 4.22.1 US Postnet ........................................................................................................................ 155 4.22.2 US Planet ........................................................................................................................... 155 4.22.3 Transmit Check Digit ....................................................................................................... 155 4.23 UK Postal Code.......................................................................................................................... 156 4.23.1 UK Postal ........................................................................................................................... 156 4.23.2 Transmit Check Digit ....................................................................................................... 156 4.24 More Postal Code ..................................................................................................................... 157 4.24.1 Japan Postal ..................................................................................................................... 157 4.24.2 Australian Postal .............................................................................................................. 157 4.24.3 Dutch Postal ..................................................................................................................... 157 4.24.4 USPS 4CB/One Code/Intelligent Mail .......................................................................... 157 4.24.5 UPU FICS Postal ............................................................................................................... 158 4.25 2D Symbologies ........................................................................................................................ 159 4.25.1 PDF417 ............................................................................................................................. 159 4.25.2 MicroPDF417 .................................................................................................................... 159 4.25.3 Data Matrix ....................................................................................................................... 160 4.25.4 Maxicode ........................................................................................................................... 161 4.25.5 QR Code ............................................................................................................................. 161 4.25.6 MicroQR ............................................................................................................................. 161 4.25.7 Aztec .................................................................................................................................. 161 4.26 Macro PDF ................................................................................................................................. 162 4.26.1 Transmit/Decode Mode .................................................................................................. 162 4.26.2 Escape Characters ........................................................................................................... 163 4.26.3 Transmit Control Header ................................................................................................ 163 DEFINING OUTPUT FORMAT ................................................................................................................ 165 5.1 Letter Case ................................................................................................................................... 165 5.2 Character Substitution ............................................................................................................... 166 5.2.1 Select a Set for Character Substituion ............................................................................ 167 5.2.2 Symbologies for Character Substitution (All 3 Sets) .................................................... 168 5.3 Prefix/Suffix Code ....................................................................................................................... 178 5.4 Code ID ......................................................................................................................................... 179 5.4.1 Select Pre-defined Code ID ............................................................................................... 179 5.4.2 Change Code ID .................................................................................................................. 182 5.4.3 Clear Code ID Settings ....................................................................................................... 185 5.5 Length Code ................................................................................................................................. 186 5.6 Multi-Barcode Editor ................................................................................................................... 194 5.6.1 Edit a Concatenation of Barcodes ................................................................................... 195 5.6.2 Activate the Concatenation of Barcodes ........................................................................ 197 5.7 Removal of Special Character .................................................................................................. 198 APPLYING FORMATS FOR DATA EDITING .......................................................................................... 199 6.1 Activating Editing Formats ........................................................................................................ 200 6.1.1 Activate Editing Formats ................................................................................................... 200 6.1.2 Exclusive Data Editing ....................................................................................................... 201 6.2 How to Configure Editing Formats ............................................................................................ 202 6.2.1 Select Format to Configure ............................................................................................... 203
 1664 Barcode Scanner User Guide  6.2.2 Restore Default Format ..................................................................................................... 204 6.3 Configuring Format — Define Data Criteria ............................................................................. 205 6.3.1 Applicable Code Type ........................................................................................................ 205 6.3.2 Data Length ......................................................................................................................... 215 6.3.3 Matching String & Location .............................................................................................. 216 6.4 Configuring Format — Define Data Field ................................................................................. 217 6.4.1 Start Position ...................................................................................................................... 217 6.4.2 Field Adjustment ................................................................................................................ 217 6.4.3 Total Number of Fields ...................................................................................................... 218 6.4.4 Field Settings ...................................................................................................................... 219 6.4.5 Pause Field Setting ............................................................................................................ 225 6.5 Configuring Format — Define Transmission Sequence ......................................................... 226 6.6 Programming Examples ............................................................................................................ 228 6.6.1 Example I ............................................................................................................................. 228 6.6.2 Example II ............................................................................................................................ 229 SPECIFICATIONS ................................................................................................................................... 231 FIRMWARE UPGRADE .......................................................................................................................... 233 How to Upgrade Firmware ................................................................................................................ 233 Using 3610 .................................................................................................................................... 233 Using Direct USB Virtual COM ..................................................................................................... 235 Using Bluetooth® Dongle ............................................................................................................. 236 How to Upgrade 3610 Firmware ..................................................................................................... 238 Upgrading 3610 CPU Firmware .................................................................................................. 238 Upgrading 3610 USB Bridge Firmware ..................................................................................... 239 HOST SERIAL COMMANDS .................................................................................................................. 241 Serial Commands .............................................................................................................................. 241 Example ......................................................................................................................................... 242 3610 Setup Barcodes & Serial Commands .................................................................................. 243 3610 Serial Command Table ..................................................................................................... 244 Example ......................................................................................................................................... 246 KEYBOARD WEDGE TABLE .................................................................................................................. 247 Key Type & Status .............................................................................................................................. 248 Key Type ......................................................................................................................................... 248 Key Status ...................................................................................................................................... 248 Example ............................................................................................................................................... 249 NUMERAL SYSTEMS ............................................................................................................................. 251 Decimal System ................................................................................................................................. 251 Hexadecimal System ......................................................................................................................... 252 ASCII Table .......................................................................................................................................... 253 Entering PIN Code for Authentication ............................................................................................. 254 Use Preset PIN .............................................................................................................................. 254 Disable Authentication or Use Random PIN ............................................................................ 255
    1 Update  CipherLab’s small-form-factor 1600 Series Barcode Scanners are specifically designed to answer the mobile demands. The palm-sized scanners are designed to help accelerate productivity while lowering the total cost of ownership. Intensive data collection jobs are made easier with fast, accurate barcode scanning in various working environments, especially in small businesses. Integrating short-distance cordless technology to small-form-factor scanners, the scanners are ideal for carrying as in pocket, and thus give workers tether-free mobility anytime anywhere and get job done more efficiently. This line of scanners deliver data over a cordless personal network at a range of up to 10 meters and a prolonged battery life to keep business running. 1664 is a new ordering option provided for adapting a 2D scan engine to read both 1D and 2D barcodes. Owing to the compact design, extremely low power consumption, and powerful decoding capability, the 1600 Series Barcode Scanners are the best choice for the following applications –   Receiving in Retail  Product labeling & Tracking  Shelf Product Replenishment  Mobile Point of Sale (POS)   Mobile Inventory Management  Order Picking & Staging  Work-In-Process Tracking  Material Flow Control  Transportation & Distribution  Warehousing  Asset Management  This manual contains information on operating the scanner and using its features. We recommend you to keep one copy of the manual at hand for quick reference or maintenance purposes. To avoid any improper disposal or operation, please read the manual thoroughly before use.  Thank you for choosing CipherLab products!     INTRODUCTION
2 Enter Setup 1664 Barcode Scanner User Guide  GETTING FAMILIARIZED WITH 1664 AND 3610 INSTALLING THE BATTERY TO 1664 1) Hold the scanner face down in one hand, press the battery cover, and slide the battery cover. 2) Remove the battery cover to the other hand. 3) Push battery lock to unlocked position.       4) Hold the scanner still and insert the battery into the battery compartment.   For 1664, install a rechargeable 3.7V/850mAh Li-ion battery into the battery compartment. 5) Push battery lock to lock the battery firmly. 6) Replace the battery cover. 7) Hold down the [Power/Delete] key for about 2 seconds to turn on the scanner.  The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly.
    3 Update  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。                                 Note: (1) To turn off the scanner, press the [Power/Delete] key for 2 seconds. The scanner will respond with two short beeps (high tone) and the LED will finally become solid red. Release the key then. Otherwise, let the scanner turn off automatically in specific circumstances. Refer to settings of “Auto Power Off”.  (2) For shipping and storage purposes, save the scanner and the batteries separately. This will keep the batteries in good condition for future use. CHARGING THE BATTERY The battery may not be charged to full for shipment. For first receive the package, it is better to charge the battery to full before using the scanner. For 1664, use the Direct USB cable to connect the scanner to PC for charging. It takes approximately 4 hours to charge the battery to full. Refer to 1.13 Using Direct USB Cable. Note:  Battery charging stops when the temperature drops below 0°C or exceeds 40°C. It is recommended to charge the battery at room temperature (18°C to 25°C) for optimal performance.   1) Install the battery to 1664. 2) Connect 1664 to host computer or notebook via the USB cable.  3) The scanner LED will be flashing red during charging.  When the charging is done, the LED will turn off.  When charging error occurs, the LED will turn solid red. For example, a bad or missing battery issue occurs.
4 Enter Setup 1664 Barcode Scanner User Guide  CHARGING THE BATTERY VIA CHARGER The battery charger is provided for charging the battery only. You may purchase the charger separately. It takes approximately 3 hours to charge the battery to full. Note:  Battery charging stops when the temperature drops below 0°C or exceeds 40°C. It is recommended to charge the battery at room temperature (18°C to 25°C) for optimal performance.  1) Insert the battery. 2) Connect the power supply cord to the charger. 3) Connect the other end of the power cord to a suitable power outlet.                          Status LED  Meaning Red, solid  ---  Charger power ON (LED on for 0.5 second) Red, solid  --- Charging battery --- Green, solid  Charging done ---  ---  Power or battery not ready
    5 Update  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 USING 3610 The CipherLab Dongle(3610) is specifically designed for the scanner to communicate with a host computer cordless. The connection between the scanners and 3610 is made easy and reliable. Refer to 3.1.1 Connect to 3610.   There is one LED indicator provided for communications status. Communication LED  Meaning --- Blue, solid  Initialize Red, solid  ---  Failed to establish a USB connection Red, solid  Blue, flashing  Serial command mode with USB Virtual COM: wait 3 seconds for starting a serial command Red, flashing  Blue, flashing  Serial command mode with USB HID: wait 3 seconds for pressing [Num Lock] or [Caps Lock] 5 times via keyboard --- Blue, flashing  Wait for connection request from the scanner (Slow flash at 0.5 Hz) --- Blue, flashing  Connected with the scanner (Fast flash at 1 Hz) Red, solid  Blue, flashing  Failed to send data to host via USB Virtual COM (Fast flash at 1 Hz) Red, flashing  ---  Enter Download Mode
6 Enter Setup 1664 Barcode Scanner User Guide  INSIDE THE PACKAGE The items included in the package may be different, depending on your order. Save the box and packaging material for future use in case you need to store or ship the scanner.  1664 Scanner  CipherLab Dongle (3610) Optional  Rechargeable Li-ion Battery Pack  Direct USB Cable   Wristband  Setup Cards  Quick Start Guide  Product CD Note: The CD-ROM includes this manual and Windows-based ScanMaster software for configuration, as well as the USB Virtual COM driver. PRODUCT HIGHLIGHTS  Small-form-factor and built tough to survive drop test  Extremely low power consumption  Firmware upgradeable  Supports most popular barcode symbologies, including GS1-128 (EAN-128), GS1 DataBar (RSS), etc.  Supports negative barcodes  Supports a variety of 2D symbologies, Time Stamp and Paging function   Supports different scan modes, including Aiming Mode and Multi-Barcode ModeNote  User feedback via LED indicator, beeper and vibrator  Beeping tone and duration programmable for Good Read  4MB flash memory for Memory Mode operation, storing over 240,000 scans based on EAN-13 barcodes   Provides up to 10 KB SRAM for reserve buffer while getting out of range over a wireless personal area network (WPAN), storing up to 640 scans based on EAN-13 barcodes  Capable of transmitting scanned data, emulating a serial cable (Bluetooth® SPP) or as keyboard input (Bluetooth® HID), to a notebook computer or PDA with Bluetooth® wireless technology  Programmable parameters include data output format, editing format, symbologies, etc.  Easy configuration through ScanMaster  Easy connection through CipherConnect, available via online marketplace for mobile devices running on Android 2.x, BlackBerry 5.x, or Windows Mobile 6.x
    7 Update  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 SYMBOLOGIES SUPPORTED Most of the popular barcode symbologies are supported, as listed below. Each can be individually enabled or disabled. The scanner will automatically discriminate and recognize all the symbologies that are enabled. Refer to Chapter 4 Changing Symbology Settings for details of each symbology. Symbologies Supported: Enable/Disable  Default Codabar  Enabled  Code 93  Enabled  MSI   Disabled Code 128 Code 128  Enabled   GS1-128 (EAN-128)  Enabled   ISBT 128  Enabled   Code 2 of 5 Industrial 25   Enabled   Interleaved 25  Enabled   Matrix 25    Disabled Chinese 25    Disabled Code 3 of 9 Code 39  Enabled   Italian Pharmacode     Disabled Trioptic Code 39    Disabled EAN/UPC EAN-8  Enabled   EAN-8 Addon 2    Disabled EAN-8 Addon 5    Disabled EAN-13 Enabled  EAN-13 & UPC-A Addon 2    Disabled EAN-13 & UPC-A Addon 5    Disabled ISBN  Disabled UPC-E0 Enabled  UPC-E1  Disabled UPC-E Addon 2    Disabled UPC-E Addon 5    Disabled UPC-A Enabled  GS1 DataBar (RSS) GS1 DataBar Omnidirectional (RSS-14)    Disabled GS1 DataBar Truncated    Disabled GS1 DataBar Stacked    Disabled GS1 DataBar Stacked Omnidirectional    Disabled
8 Enter Setup 1664 Barcode Scanner User Guide  GS1 DataBar Limited (RSS Limited)    Disabled GS1 DataBar Expanded (RSS Expanded)    Disabled GS1 DataBar Expanded Stacked    Disabled Code 11   Disabled Composite Code Composite CC-A/B    Disabled Composite CC-C    Disabled Composite TLC-39    Disabled Postal Code US Postnet  Enabled   US Planet  Enabled   UK Postal  Enabled   Japan Postal  Enabled   Australian Postal  Enabled   Dutch Postal  Enabled   USPS 4CB/One Code/Intelligent Mail    Disabled UPU FICS Postal    Disabled 2D Symbologies PDF417 Enabled  MicroPDF417  Disabled Data Matrix  Enabled   Maxicode Enabled  QR Code  Enabled   MicroQR Enabled  Aztec Enabled
    9 Update  The configuration of the scanner can be done by reading the setup barcodes contained in this manual or via the ScanMaster software.  This section describes the procedure of configuring the scanner by reading the setup barcodes and provides some examples for demonstration. Configuration Mode 1.  Hold down the [Power/Delete] key for about 2 seconds to turn on the scanner. It will respond with a long beep and its LED will come on-off shortly. 2.  Have the scanner read the “Enter Setup” barcode. It will respond with six beeps and its LED indicator will become flashing red after reading the barcode. 3.  Have the scanner read more setup barcodes… Most of the setup barcodes are normal, and the scanner will respond with two beeps (low-high tone). For special setup barcodes, it requires reading more than one setup barcode to complete the setting. 4.  Have the scanner read the “Update” or “Abort” barcode. It will respond with six beeps and its LED indicator will become flashing red after reading the barcode. 5.  The scanner will restart automatically upon reading the “Update” or “Abort” barcode. It will respond with a long beep and its LED will come on-off shortly.  Note: Refer to Appendix II Host Serial Commands for how to configure the 3610 dongle by having the scanner read 3610-related setup barcodes or using serial commands.  QUICK START
10 Enter Setup 1664 Barcode Scanner User Guide  Working Mode Upon powering up, the scanner will try to establish a connection with 3610 or a computer with Bluetooth® wireless technology. Refer to Chapter 3 - Setting up a WPAN Connection for details. The connection between the scanners and 3610 is made easy and reliable. Now, it also supports Bluetooth® SPP Master Mode as an alternative. Refer to 2.3 Bluetooth® SPP Master.     Note: If USB Virtual COM or Bluetooth® SPP is selected for output interface, the host can directly send serial commands to configure the scanner. For example, run HyperTerminal.exe and type the 6-digit command located under each setup barcode. Refer to Appendix II Host Serial Commands.
    11 Update  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 ENTER CONFIGURATION MODE For the scanner to enter the configuration mode, you must have it read the "Enter Setup" barcode, which can be located at the bottom of almost every even page of this manual.   The scanner will respond with six beeps and its LED indicator will become flashing red after reading the barcode.   Enter Setup For configuring scanner parameters, see “Read a Setup Barcode” below. EXIT CONFIGURATION MODE For the scanner to save settings and exit the configuration mode, read the “Update” barcode, which can be located at the bottom of almost every odd page of this manual. Exit the configuration mode without saving any changes; have the scanner read the “Abort” barcode instead.   Just like reading the “Enter Setup” barcode, the scanner will respond with six beeps and its LED indicator will become flashing red after reading the barcode. Wait for a few seconds for the scanner to restart itself.   Update Abort
12 Enter Setup 1664 Barcode Scanner User Guide  DEFAULT SETTINGS SAVE USER SETTINGS AS DEFAULTS For the scanner to keep the customized settings as user defaults, you must have it read the “Save as User Defaults” barcode. This is a normal setup barcode, and the scanner will respond with two beeps (low-high tone).  After reading the “Update” barcode, the current settings will be saved as user defaults.   Save as User  DefaultsRESTORE USER DEFAULTS For the scanner to restore the user defaults, which you have saved earlier, you must have it read the “Restore User Defaults” barcode. This is a normal setup barcode, and the scanner will respond with two beeps (low-high tone).  After reading the “Update” barcode, all the parameters of the scanner will return to their customized values.    Restore User DefaultsRESTORE SYSTEM DEFAULTS For the scanner to restore the factory defaults, have it read the “Restore System Defaults” barcode. This is a normal setup barcode, and the scanner will respond with two beeps (low-high tone). After reading the “Update” barcode, all the parameters of the scanner will return to their default values. The current connection record will be cleared as well. Refer to 1.18.1 Restore System Defaults for the key combination used to restore defaults during operation.  For 3610 to restore factory defaults, refer to 3610 Setup Barcodes & Serial Commands.   Restore System DefaultsNote: The system default value (if there is) for each setting is indicated by an asterisk “*”.
    13 Update  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 READ A SETUP BARCODE CONFIGURE PARAMETERS For most of the scanner parameters, only one read is required to set them to new values. The scanner will respond with two beeps (low-high tone) when each parameter is set successfully. Refer to Create One-Scan Setup Barcodes. But for a number of special parameters, multiple reads are required to complete the setting. In this case, the scanner will respond with a short beep to indicate it needs to read more setup barcodes. These special parameters may require reading one or more setup barcodes, such as  Numeric barcodes, say, for keyboard type, inter-character delay, length qualification  Hexadecimal barcodes, say, for character strings as prefix, suffix, etc.  When “Bluetooth® HID” or “USB HID” is configured for interface, Key Type and Key Status will then become applicable. Decide whether to change key status when “Normal Key” is selected for Key Type. To complete the configuration of these special parameters, it requires reading the “Validate” barcode, and the scanner will respond with two beeps (low-high tone) to indicate the input values are validated.
14 Enter Setup 1664 Barcode Scanner User Guide  The example below shows how to save your settings as “User Default” so that you may restore user defaults at a later time: Steps  Action  User Feedback if Successful 1  Power on the scanner… The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. 2  Enter the Configuration Mode…  The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will be flashing red.  3  Read a Setup barcode… For example,               The scanner will respond with two beeps (low-high tone) if reading a normal setup barcode. 4  Exit the Configuration Mode…      OR    Same as for Enter the Configuration Mode. 5  The scanner will automatically restart itself…  Same as for Power on the scanner. *  When any configuration error occurs...  The scanner will respond with one long beep (low tone).
    15 Update  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 The example below shows how to set numeric parameters: Steps  Action  User Feedback if Successful 1  Power on the scanner...  The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. 2  Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red.  3  Read a Setup barcode... For example,     The scanner will respond with two beeps (low-high tone) if reading a normal setup barcode.        The scanner will respond with one short beep if reading a special setup barcode such as “Max. Length”, indicating the setup requires reading more barcodes.   Read the “Decimal Value” barcode(s).  Refer to Appendix IV “Decimal System”      The scanner will respond with two beeps (low-high tone) when the input values are validated. 4  Exit the Configuration Mode…   OR     Same as for Enter the Configuration Mode. 5  The scanner will automatically restart itself…  Same as for Power on the scanner.  Normal setup barcode Normal setup barcode Special setup barcode Decimal barcodes
16 Enter Setup 1664 Barcode Scanner User Guide  The example below shows how to set string parameters: Steps  Action  User Feedback if Successful 1  Power on the scanner... The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. 2  Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red.  3  Read a Setup barcode... For example,   The scanner will respond with one short beep if reading a special setup barcode such as “Prefix Code”, indicating the setup requires reading more barcodes.       When “Bluetooth® HID” or “USB HID” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to change key status when “Normal Key” is selected for Key Type.  Refer to Appendix III     Read the “Hexadecimal Value” barcodes for the desired character string. For example, read “2” and “B” for the scanner to prefix the character “+”.  Refer to Appendix IV “Hexadecimal System”   The scanner will respond with two beeps (low-high tone) when the input values are validated. 4  Exit the Configuration Mode…   OR     Same as for Enter the Configuration Mode. 5  The scanner will automatically restart itself…  Same as for Power on the scanner.   Special setup barcodes Hexadecimal barcodes
    17 Update  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 LIST THE CURRENT SETTINGS The current settings of all scanner parameters can be sent to the host computer for user inspection. The listing includes pages as shown below. You can select the page of interest by having the scanner read the “List Page x” barcode. The scanner will respond with two beeps (low-high tone) and send the selected page to the host immediately.  List settings regarding Firmware Version, Serial Number, Interface, Buzzer, and Other Scanner Parameters  List Page 1List settings regarding Prefix, Suffix, and Length Code Setting (1/2)  List Page 2List settings regarding Prefix, Suffix, and Length Code Setting (2/2)  List Page 3List settings regarding Code ID   List Page 4List settings regarding: Readable Symbologies (1/2)  List Page 5List settings regarding: Readable Symbologies (2/2)  List Page 6List settings regarding Symbology Parameters (1/3)  List Page 7List settings regarding Symbology Parameters (2/3)  List Page 8List settings regarding Symbology Parameters (3/3)  List Page 9Reserved  List Page 10
18 Enter Setup 1664 Barcode Scanner User Guide  List settings regarding Editing Format 1  (1/2)  List Page 11List settings regarding Editing Format 1  (2/2)  List Page 12List settings regarding Editing Format 2  (1/2)  List Page 13List settings regarding Editing Format 2  (2/2)  List Page 14List settings regarding Editing Format 3 (1/2)  List Page 15List settings regarding Editing Format 3 (2/2)  List Page 16List settings regarding Editing Format 4  (1/2)  List Page 17List settings regarding Editing Format 4  (2/2)  List Page 18List settings regarding Editing Format 5 (1/2)  List Page 19List settings regarding Editing Format 5 (2/2)  List Page 20List settings presently    List Page 21
    19 Update  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 CREATE ONE-SCAN SETUP BARCODES The fact is most of the scanner parameters require only one read for setting new values. To facilitate configuring the scanner, you may create One-Scan setup barcodes for use.  The requirements of a One-Scan setup barcode are:   a prefix of the “#@” characters  the six digits of command parameters  a suffix of the “#”character  For example, the scanner needs reading three setup barcodes for the command parameter “109952” to take effect:   Enter Setup List Page 3 Update Now, it requires only one read:   One-Scan Setup Barcode for 109952Note: The scanner will restart automatically upon reading the One-Scan setup barcode for (1) changing the interface or (2) setting memory mode, enable or disable. It will respond with a long beep and its LED will come on-off shortly.
20 Enter Setup 1664 Barcode Scanner User Guide
    21 Update  This chapter explains the features and usage of the barcode scanner.  IN THIS CHAPTER 1.1 Battery ..................................................................... 21 1.2 Memory .................................................................... 26 1.3 LED Indicator ............................................................ 29 1.4 Beeper ..................................................................... 31 1.5 Vibrator .................................................................... 34 1.6 Send “NR” to Host ..................................................... 35 1.7 Scan Modes .............................................................. 36 1.8 Scanning Timeout ......................................................  39 1.9 Delay between Re-read............................................... 40 1.10 Read Redundancy for All Symblogies ........................... 41 1.11 Addon Security for UPC/EAN Barcodes ........................ 42 1.12 Negative Barcodes ................................................... 42 1.13 Using Direct USB Cable ............................................. 43 1.14 Picklist Mode ........................................................... 44 1.15 Pager Beep Duration ................................................. 44 1.16 Time Stamp ............................................................ 45 1.17 2D Decode Setting ................................................... 49 1.18 Hardware Reset ....................................................... 50 1.1 BATTERY The scanner is battery-powered: Use a rechargeable 3.7 V/850 mAh Li-ion battery. For intensive data collection, please prepare spare battery or batteries for non-stop operation. Note:  (1) The rechargeable battery for 1664 may not be charged to full for shipment. We suggest charging it to full before use.               (2) The scanner can be configured to save battery power. Refer to settings of “Auto Power Off & Power-Saving”, “Sniff Mode”, as well as “Low Battery Alarm”.         Chapter 1 UNDERSTANDING THE BARCODE SCANNER
22 Enter Setup 1664 Barcode Scanner User Guide  1.1.1 HOW TO OPERATE THE SCANNER Turn on the scanner… Press the [Power/Delete] key for about 2 seconds. The scanner will respond with a long beep (high tone), and its LED indicator will become solid red and go off quickly. Turn off the scanner… Press the [Power/Delete] key for about 2 seconds. The scanner will respond with two short beeps (high tone) and the LED will finally become solid red. Release the key then. Otherwise, let the scanner turn off automatically in specific circumstances. Delete the last collected data when in memory mode … Press the [Power/Delete] key. The scanner will respond with two short beeps (high tone) and the LED will become solid red. Before the LED goes off (within 1 second), press the [Power/Delete] key again to confirm the deletion.
    23 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.1.2 AUTO POWER OFF & POWER-SAVING The scanner will stay active at power-on, which may be followed by a transition from full CPU speed to low CPU speed (Power-Saving) to auto shutdown (Auto Power Off).  Power-Saving (1~254 min.; 0= Disable): By default, it is set to stand by at full-speed for 2 minutes before it enters low-speed mode. If this feature is not desired, set it to 0.  Auto Power Off (1~254 min.; 0= Disable): By default, it is set to automatically shut down after 10 minutes. If this feature is not desired, set it to 0. Note: The Power-Saving setting will still take effect once a connection has been established successfully, via Bluetooth® HID or SPP.    Before establishing a WPAN connection successfully… 1.  The scanner will stay active for a specified period of time (2 minutes by default) for the following scenarios. Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio 0.5 s: 0.5 s). (a) waiting for a connection request from the host (Bluetooth® SPP Slave Mode) (b) trying to connect to the host (Bluetooth® HID or Bluetooth® SPP Master Mode) (c) trying to connect to 3610 2.  If it fails to connect within 2 minutes, the scanner will become inactive to save power for the remaining period of time (the specified value minus 2 minutes). Its CPU is running at low speed, and the LED is flashing red (On/Off ratio 0.3 s: 2.5 s). Press the [Trigger] key to wake up the scanner when it becomes inactive, and the scanner will stay active again. 3.  If it fails to connect again and again, and finally stays inactive until the specified time interval for Auto Power Off has elapsed, the scanner will automatically turn off in order to conserve battery power. Hold down the [Power/Delete] key for about 2 seconds to turn it on.  Note: For scenarios (a) and (b) in step 1, on your computer you may need to search for the scanner again.
24 Enter Setup 1664 Barcode Scanner User Guide  After establishing a WPAN connection successfully… 1.  Once a WPAN connection is established successfully, the scanner will stay active for a specified period of time (2 minutes by default) for data transmission. Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio 0.02 s: 3 s). 2.  If it is idle within 2 minutes, the scanner will become inactive to save power for the remaining period of time (the specified value minus 2 minutes). Its CPU is running at low speed, and the LED is flashing red (On/Off ratio 0.3 s: 2.5 s).  Press the [Trigger] key to wake up the scanner when it becomes inactive, and the scanner will stay active again. 3.  If it is idle and finally stays inactive until the specified time interval for Auto Power Off has elapsed, the scanner will automatically turn off in order to conserve battery power. The three short beeps will ring out, tone descending from high to low. Hold down the [Power/Delete] key for about 2 seconds to turn it on.    For Bluetooth® HID, the scanner will resume connection with the host upon powering on again, as long as the host application is running. The three short beeps will ring out, tone ascending from low to high. If the scanner fails to resume connection, it will try every 5 seconds to re-connect to the host unless the scanner read the “Reset Connection” barcode.  For Bluetooth® SPP Slave Mode, the scanner must wait for the host to re-connect.  For Bluetooth® SPP Master Mode, the scanner will resume connection with the host upon powering on again, as long as the host application is running. The three short beeps will ring out, tone ascending from low to high. If the scanner fails to resume connection, it will try every 5 seconds to re-connect to the host unless the scanner read the “Reset Connection” or “Restore System Defaults” barcode.  With the use of 3610, the scanner will try re-connecting to 3610 unless to turn off the scanner.
    25 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。  Auto Off after  0~254 min. (*10)1) Read the barcode above to specify the time interval before the scanner automatically turns off. 2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “5” for the scanner to automatically turn off after being idle for 15 minutes.  3) Read the “Validate” barcode on the same page to complete this setting. Note:  Auto Power Off will not take effect when the scanner is in the configuration mode.   Power-Saving after  0~254 min. (*2)1) Read the barcode above to specify the time interval before the scanner enters low-speed mode. 2) Read the “Decimal Value” barcode on page 251. For example, read “5” for the scanner to enter low-speed mode after being idle for 5 minutes.  3) Read the “Validate” barcode on the same page to complete this setting. Note:  Power-Saving will not take effect when one of the following conditions is met:   (1) The scanner is in the configuration mode.            (2) The Power-Saving value is set to 0.                                                           (3) The setting value of Power-Saving is greater than that of Auto Power Off.
26 Enter Setup 1664 Barcode Scanner User Guide  1.2 MEMORY The collected data can be sent back to a host computer one by one via the WPAN connection or stored in flash memory when the scanner is set to Memory mode. 1.2.1 TRANSMIT BUFFER By default, transmit buffer is enabled and for use when the scanner is out of range. Upon reading a barcode successfully within range, the scanner responds with one short beep (high tone) and its LED indicator becomes solid green and goes off quickly. However, the host computer may not receive the data immediately if getting out of range. With the 10 KB transmit buffer, the scanner can ignore the transmission status and keep on reading barcodes until the buffer is full.  When transmit buffer is enabled… If the scanner is out of range, it will respond with two short beeps, high-low tone, upon reading a barcode successfully. When transmit buffer is full, the scanner will respond with one long beep (low tone) and its LED indicator will become solid red and go off quickly. You are advised to get back to range. When transmit buffer is disabled… If the scanner is out of range, it will respond with one long beep (low tone) and its LED indicator will become solid red and go off quickly. You are advised to get back to range.   *Enable DisableNote:  The 10 KB transmit buffer on the scanner can hold as many as 640 scans based on EAN-13 barcodes. Data will be cleared out once the scanner is turned off or running out of battery power!
    27 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.2.2 MEMORY MODE When the scanner is in memory mode, it means any real-time connection established with the host is disabled. 1664 scanner keeps 4MB flash memory for memory mode operation, which can store over 240,000 scans based on EAN-13 barcodes.  Enable *DisableWarning:  No real-time connection is allowed unless the memory mode is disabled. Memory Data Delay You may set a delay between each data record while transmitting data back to the host.  *None 250 ms 500 ms 1 sec 2 sec 3 sec 5 sec
28 Enter Setup 1664 Barcode Scanner User Guide   8 secSend Data When the memory is used up, the scanner will respond with two short beeps (high-low tone) as a warning. It is advised to send data to the host immediately by having the scanner read the “Send Data” barcode below.  1664 can send data via “Direct USB” interface once the computer has found the USB connection. Refer to 1.13 Using Direct USB Cable. Because the time-out value is set to 0 by default, connect the cable before having the scanner read the “Send Data” barcode. Otherwise, the scanner will try to temporarily resume the previous WPAN connection with the host, if there is any. During data transmission upon memory mode, if the data is transmitted fail, the scanner will flash red (On/Off ratio 0.2 s: 0.2 s) after responding two short beeps (high-low tone) and go back to previous working mode. Press trigger or power key to stop flashing.  Send DataSend Data Time-out if a time-out value other than zero is given, it will first try to send data via “Direct USB” interface within the specified period of time. Connect the cable before it times out. When the attempt fails, it will try to temporarily resume the previous WPAN connection with the host, if there is any.  If 1664 has never been connected to the host cordless, it will not be able to send data until to connect the Direct USB cable!  Send Data Time-Out after 0~15 sec.  (*0)Clear Data & Confirm Even though data has been sent back to the host, the flash memory is still occupied unless you erase the memory by having the scanner read two barcodes – “Clear Data” and “Confirm”. 1.  Read the “Clear Data” barcode to clear the flash memory. 2.  Read the “Confirm” barcode to confirm the action.  Clear Data Confirm
    29 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.3 LED INDICATOR The triple-color LED on top of the scanner is used to provide user feedback. For example, the LED becomes solid red and goes off quickly upon powering on or running out of transmit buffer. You may tell the difference by the beeps – you will hear a long beep of high tone when powering on the scanner, and a long beep of low tone when the transmit buffer becomes full.  Scanner LED  Meaning Red, on-off  --- ---  Power on, with one long beep (high tone, LED on for 1 second)  Data saved to buffer when transmit buffer is enabled and the scanner is out of range, with two short beeps (high-low tone)  Transmit buffer full, with one long beep (low tone)  Transmit buffer disabled, with one long beep (low tone)  Delete the last collected data in memory mode, with two short beeps (high tone, LED on for 1 second)  Memory full in memory mode, with two short beeps (high-low tone) Red, flashing  --- ---  Flashing red (On/Off ratio 0.3 s: 2.5 s) indicates the scanner is inactive and its CPU running at low speed to save power (because no WPAN connection is established after waiting for two minutes)  Configuration Mode (On/Off ratio 0.5 s: 0.5 s) --- --- Green, on-off  Good Read, with one short beep (high tone) and beeper pitch and duration programmable --- Blue, flashing  ---  First, flashing blue (On/Off ratio 0.5 s: 0.5 s) for two minutes indicates the scanner is waiting for connection, and goes off if no connection is established, then flashing red (On/Off ratio 0.3 s: 2.5 s) indicates the scanner is inactive. It is ready for connection only while the LED is flashing blue —  SPP Slave: waiting host to connect  HID or SPP Master: trying to connect to host  Using 3610: trying to connect to 3610 --- Blue, flashing  ---  Flashing blue (On/Off ratio 0.1 s: 0.1 s) indicates the scanner receives a PIN code request from host (flashing more quickly than waiting connection). --- Blue, flashing  ---  Flashing blue (On/Off ratio 0.02 s: 3 s) indicates the scanner has established a WPAN connection successfully. --- Blue, flashing  Green, flashing  Flashing blue and green (On/Off ratio 0.1 s: 0.1 s) indicates an error occurs while entering the PIN code. Press the [Trigger] key to get ready for re-connecting. Red, flashing  ---  ---  Flashing red (On/Off ratio 0.2 s: 0.2 s) indicates the scanner has transmit fail upon memory mode. Press any key to stop flashing.
30 Enter Setup 1664 Barcode Scanner User Guide  1.3.1 GOOD READ LED  *Enable  Good Read LED Disable  Good Read LED 1.3.2 GOOD READ LED DURATION By default, the Good Read LED stays on for 40 milliseconds. Specify a value, ranging from 1 to 254 in units of 10 milliseconds.   Good Read LED Time-out after 0.01~2.54 sec.  (*40 ms)1) Read the barcode above to specify the time interval before the Good Read LED goes off. 2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “5” for the LED to go off after 150 milliseconds.  3) Read the “Validate” barcode on the same page to complete this setting.
    31 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.4 BEEPER The scanner has a buzzer to provide user feedback in various operating conditions. Beeping  Meaning One long beep, high tone  Power on, with red LED on (1 second) and off quickly One long beep, low tone   Transmit buffer full, with red LED on-off quickly  Transmit buffer disabled, with red LED on-off quickly  Configuration error (Wrong barcode…)  PIN code input error  Reject random PIN request  Fail to send data in memory mode One short beep, high tone  Programmable, default to 4 KHz Good Read, with green LED on-off quickly One short beep, high tone   More setup barcode required  Input PIN code  Clear PIN code One short beep, low tone  More barcodes required to complete the “output sequence” requirements of Multi-Barcode Editor, with green LED on-off quickly (Upon completion, same as Good Read.) Six short beeps  High-low tone repeats three times  Enter Configuration Mode, with red LED flashing  Exit Configuration Mode Two short beeps, low-high tone  Setup barcode read successfully Two short beeps, high tone   Low Battery Alarm  Power off, with red LED on (until the key is released)  Delete the last collected data in memory mode, with red LED on (1 second) and off quickly  Wake up the scanner depends on the paging setting value until pressing the power key or reaching the sleeping time out. Two short beeps, high-low tone   Data saved to buffer when transmit buffer is enabled and the scanner is out of range, with red LED on-off quickly  Memory Mode – Memory full, with red LED on-off quickly  Memory Mode – Transmitting fail, with red LED flashing Two long beeps, high-low tone  Multi-Barcode Mode – Buffer full Three short beeps, tone ascending from high to low  WPAN connection out of range or suspended Three short beeps, tone ascending from low to high  WPAN connection established, with blue LED flashing  WPAN connection resumed, with blue LED flashing
32 Enter Setup 1664 Barcode Scanner User Guide  1.4.1 BEEPER VOLUME  Mute Minimum Volume Medium Volume *Maximum Volume
    33 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.4.2 GOOD READ BEEP Frequency  8 kHz *4 kHz 2 kHz 1 kHzDuration  *Shortest Shorter Longer Longest
34 Enter Setup 1664 Barcode Scanner User Guide  1.4.3 LOW BATTERY ALARM By default, it will activate the beeper to give a warning when the battery charge gets low. In order to prevent data loss, it is advised to replace the battery immediately when hearing two short beeps (high tone).   Disable *Enable 1.5 VIBRATOR   1.5.1 GOOD READ VIBRATOR  Enable  Good Read Vibrator *Disable  Good Read Vibrator 1.5.2 GOOD READ VIBRATOR DURATION By default, the Good Read Vibration stays on for 1 second. Specify a value, ranging from 1 to 254 in units of 100 milliseconds.   Good Read Vibrator Time-out after 0.1~25.4 sec.  (*1 s)1) Read the barcode above to specify the time interval before the Good Read Vibrator goes off. 2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “5” for the vibrator to vibrate after 1.5 seconds good read.  3) Read the “Validate” barcode on the same page to complete this setting.
    35 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.6 SEND “NR” TO HOST The scanner can send the “NR” string to the host to notify the No Read event.   Enable *Disable
36 Enter Setup 1664 Barcode Scanner User Guide  1.7 SCAN MODES Different scan modes are supported – select the scan mode that best suits the requirements of a specific application. Refer to the comparison table below.  Scan Mode  Start to Scan  Stop Scanning  Always Press trigger once Hold trigger  Press trigger twice Release trigger  Press trigger once Barcode being read Timeout Laser mode          Auto Off mode          Auto Power Off mode          Aiming mode           Multi-Barcode  mode            Note:  By default, the scan mode is set to Laser mode.   1.7.1 LASER MODE The scanner will start scanning once the trigger is held down.  The scanning won't stop until (1) a barcode is decoded, (2) the pre-set timeout expires, or (3) you release the trigger. Note:  Refer to “Scanning Timeout”.   *Laser Mode
    37 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.7.2 AUTO OFF MODE The scanner will start scanning once the trigger is pressed.  The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires. Note:  Refer to “Scanning Timeout”.   Auto Off Mode 1.7.3 AUTO POWER OFF MODE The scanner will start scanning once the trigger is pressed.  The scanning won't stop until the pre-set timeout expires, and, the pre-set timeout period re-counts after each successful decoding. Note:  Refer to “Delay between Re-read” and “Scanning Timeout”.   Auto Power Off Mode
38 Enter Setup 1664 Barcode Scanner User Guide  1.7.4 AIMING MODE The scanner will aim at a barcode once the trigger is pressed, and start scanning when the trigger is pressed again within one second.  The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires.   Aiming ModeAiming Timeout You can limit the aiming time interval (1~15). By default, the scanner time-out is set to 1 second.  Aiming Time-out after 1~15 sec.  (*1)1.  Read the barcode above to specify the time interval before aiming ends. (It is set to 1 by default.) 2. Read the “Decimal Value” barcode on page 251. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 10 seconds. 3.  Read the “Validate” barcode on the same page to complete this setting.  1.7.5 MULTI-BARCODE MODE The scanner will be scanning as long as the trigger is held down, capable of decoding one single barcode, as well as multiple unique barcodes one at a time. While decoding a bunch of unique barcodes, if a barcode is decoded twice, its subsequent decoding will be ignored and the scanner is expecting another unique barcode.  The scanning won't stop until you release the trigger.   Multi-Barcode ModeNote: (1) A barcode is considered unique when its Code Type or data is different from others.            (2) Multi-Barcode Mode has nothing to do with the Multi-Barcode Editor.
    39 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.8 SCANNING TIMEOUT Specify the scanning time interval (1~254 sec.; 0= Disable) when the scan mode is set to any of the following –  Laser mode  Auto Off mode  Auto Power Off mode  Aiming mode    Scanner Time-out after 0~254 sec.  (*10)1) Read the barcode above to specify the time interval before the scan engine times out. 2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “5” for the scanner to shut down automatically after being idle for 15 seconds.  3) Read the “Validate” barcode on the same page to complete this setting.
40 Enter Setup 1664 Barcode Scanner User Guide  1.9 DELAY BETWEEN RE-READ This is also referred to as the “Blocking Time”, which is used to prevent the scanner from accidentally reading the same barcode twice when the scan mode is set to any of the following –   Auto Power Off mode   100 ms 200 ms *400 ms 800 ms 1 sec 2 sec 3 sec 5 sec
    41 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.10 READ REDUNDANCY FOR ALL SYMBLOGIES Select the level of reading security. For example,  If "No Redundancy" is selected, one successful decoding will make the reading valid and induce the "READER Event".  If "Three Times" is selected, it will take a total of four consecutive successful decoding of the same barcode to make the reading valid. The higher the reading security is (that is, the more redundancy the user selects), the slower the reading speed gets.  It is obvious that the more redundancy selected, the higher the reading security is, and thus, the slower the reading speed becomes. It has to compromise between reading security and decoding speed.   *No Redundancy One Time Two Times  Three Times
42 Enter Setup 1664 Barcode Scanner User Guide  1.11 ADDON SECURITY FOR UPC/EAN BARCODES The scanner is capable of decoding a mix of UPC/EAN barcodes with and without addons. The read redundancy (0~30 times) allows changing the number of times to decode a UPC/EAN barcode before transmission. The more redundancy selected, the higher the reading security is, and thus, the slower the reading speed becomes. It has to compromise between reading security and decoding speed. Note: UPC/EAN Addon 2 and Addon 5 must be enabled individually for this setting to take effect.    Addon Security Level (*0~30)1) Read the barcode above to specify the read redundancy for UPC/EAN barcodes. (It is set to 0 by default.)       2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “2” for the scanner to re-read the barcode for 12 times.  3) Read the “Validate” barcode on the same page to complete this setting. 1.12 NEGATIVE BARCODES Normally, barcodes are printed with the color of the bars darker than that of the spaces. But for negative barcodes, they are printed in the opposite sense just like negative films. The spaces of negative barcodes are printed with a color darker than that of the bars. Configure the scanner to be able to read negative barcodes.   Enable *Disable
    43 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.13 USING DIRECT USB CABLE 1664 supports Direct USB interface for charging the battery and/or sending data to the host in memory mode. Refer to 1.2.2 Memory Mode.  Note:  The scanner is not allowed to function when it is solely on USB power and without a battery loaded.  1.13.1 DIRECT USB INTERFACE When it is set to Memory Mode and connected to computer via the Direct USB cable, the default output interface becomes “Direct USB Virtual COM”. Change it to “Direct USB HID”.  For details on configuring the interface settings, refer to the following sections:  2.6 Direct USB HID   2.7 Direct USB Virtual COM    *Activate Direct USB Virtual COM Activate DirectUSB HID1.13.2 DISABLE DIRECT USB INTERFACE When connecting the Direct USB cable, have the scanner to read the “Disable Direct USB” barcode in advance to avoid sending data to the host in memory mode via the cable. It will then allow charging the battery only.   Disable Direct USB
44 Enter Setup 1664 Barcode Scanner User Guide  1.14 PICKLIST MODE Picklist mode enables the decoder to decode only the barcodes aligned under the center of the laser aiming pattern.   Enable *Disable1.15 PAGER BEEP DURATION  Paging function is only activated when 1664 is in Power-Saving mode. 1664 can be waked up via receiving any Bluetooth signal or press any specific key upon Bluetooth connection. The buzzer will make two short beeps with high tone when the pager beep duration setting time is up for each time, then stop to beep until next Power-Saving time out is reached or power key is pressed. By default, the pager beep duration is 5 seconds. Specify a value, ranging from 0 to 15. (0~15 sec.; 0= Disable)   Bluetooth HID profile: Press any key among “Scroll Lock”, “Number Lock” or “Caps Lock” on the host computer to trigger the waking up of 1664.  Bluetooth SPP Profile: Any signal sent from serial port will trigger the waking up of 1664.    Pager Beep Duration 0~15 sec.  (*5 s)1) Read the barcode above to specify the activated reminding time interval. 2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “5” for the pager beep function to be activated each 15 seconds after entering Power-Saving mode.  3) Read the “Validate” barcode on the same page to complete this setting.
    45 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.16 TIME STAMP    Specify time stamp format added to the prefix or suffix of a data.  Up to three settings can be configured:  No Time Stamp  Add Time Stamp in front of data  Add Time Stamp to the end of data If added in front of data, it means front of prefix field. Alternatively, to the end of data means added it after additional field.   No Time Stamp*Disable Add Time Stamp in front of Data Add Time Stamp to the end of Data1.16.1 DATE AND TIME SETTINGS Read the barcode below to disable/enable Date and Time function.   Year Output*Enable Year OutputDisable Month Output*Enable Month OutputDisable
46 Enter Setup 1664 Barcode Scanner User Guide   Date Output*Enable Date OutputDisable Hour Output*Enable Hour OutputDiable Minute Output*Enable Minute OutputDisalbe Second Output*Enable Second OutputDiable
    47 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Decoding Data and Time  Year Setup Date Setup Time Setup1) Read the barcode above to apply time or date code separately, and follow steps 2~3.  2) Read the “Decimal Value” barcode on page 251 for the desired character string. For example: Year: Read “2”, “0”, “1”, “1” for the year setting as year=2011.  Date: Read “1”, “1”, ”2”, “0” for the date setting as date=Nov.20. Time: Read “1”, “8”, “5”, “9” for the time setting as time=18:59. 3) Read the “Validate” barcode for each setting on the same page. 1.16.2 SEPARATOR FOR DATE AND TIME The Date and Time can be split with a pre-selected separator, for example, “/” as YYYY/MM/DD or “:” as HH:MM:SS   Separator for Date/Time*“-” Separator for Month/Date*“/” Separator for Hour/Minute*“:”1) Read the barcode above to apply separator to date or time separately, and follow steps 2~3.  2) Read the “Hexadecimal Value” barcode on page 252 for the desired character string. For example, read “3” and “A” for the separator to split the data with character [:]. 3) Read the “Validate” barcode on the same page to complete this setting.
48 Enter Setup 1664 Barcode Scanner User Guide  1.16.3 DATE FORMAT The date format includes year, month and day. There are three kinds of combinations can be configured to specify Year, Month and Day:  Year/Month/Day (YYYY/MM/DD) or (YY/MM/DD)  Month/Day/Year (MM/DD/YYYY) or (MM/DD/YY)  Day/Month/Year (DD/MM/YYYY) or (DD/MM/YY)   *Year/Month/Day Month/Day/Year Day/Month/Year  About Year Format: Year format can be pre-selected as 2-digit or 4-digit. For example, if year format is YYYY, the output year is 2011 for 4-digit, alternatively is 11 for 2-digit.  *Year for 4-digit Year for 2-digit
    49 Update  Chapter 1  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 1.17 2D DECODE SETTING 1.17.1 AIMING PATTERN Decide whether to allow the decoder to project the aiming pattern during a barcode capture.  *Enable Disable1.17.2 DECODING ILLUMINATION Decide whether to cause the decoder to flash illumination on every image capture to aid decoding.  Enabling illumination usually results in superior images. The effectiveness of the illumination decreases as the distance to the target increases.  *Enable Disable
50 Enter Setup 1664 Barcode Scanner User Guide  1.18 HARDWARE RESET 1.18.1 RESTORE SYSTEM DEFAULTS Instead of having the scanner read “Restore System Defaults” barcode, use key combination, as described below, to restore system defaults during operation.  1) Hold down the [Power/Delete] key.  2) When the scanner responds with two short beeps (high tone), press the [Trigger] key for about 5 seconds. The scanner LED indicator becomes solid red for a while and then goes off. 3) When the scanner responds with a long beep (high tone), release the keys. Its LED indicator becomes solid red and goes off quickly. Note:  The scanner will restart itself automatically. 1.18.2 RESET CONNECTION When the output interface is Bluetooth® HID or Bluetooth® SPP Master, the scanner will attempt to maintain an established connection. To stop such re-connection, it may need to have the scanner read “Reset Connection” or “Restore System Defaults” barcode to clear the current connection record. Alternatively, use key combination as described below to reset connection during operation. 1) Hold down the [Trigger] key, and then press the [Power/Delete] key for at least 5 seconds. 2) The scanner will respond with two short beeps (high tone). Wait for a while until the scanner responds with a long beep (high tone), release the keys.  Note: After reset connection by hardware, the scanner will not restart itself automatically. It will resume to its previous operation except no connection.
    51 Update  In order to establish a proper connection between host computer and the scanner, we suggest following these instructions –  1) Install batteries and hold down the [Power/Delete] key for about 2 seconds to turn on the scanner. 2) Have the scanner read the “Enter Setup” barcode to enter the configuration mode. 3) Have the scanner read the associated barcodes to activate the desired interface. See the following sections for output interfaces supported. 4) Have the scanner read the barcodes for related settings. 5) Have the scanner read the “Update” barcode to exit the configuration mode. 6) Turn on host computer or laptop and establish a WPAN connection with the scanner.  Refer to Chapter 3 – Setting up a WPAN Connection. Note:  (1) By default, the output interface is set to “Bluetooth® HID”.        (2) When set to Memory Mode and connected to computer via the Direct USB cable, the default output interface becomes “Direct USB Virtual COM”.  IN THIS CHAPTER 2.1 Bluetooth® HID ......................................................... 52 2.2 Bluetooth® SPP Slave ................................................. 64 2.3 Bluetooth® SPP Master ............................................... 66 2.4 USB HID via 3610 ......................................................  70 2.5 USB Virtual COM via 3610 ...........................................  81 2.6 Direct USB HID .......................................................... 83 2.7 Direct USB Virtual COM ............................................... 94             Chapter 2 SELECTING OUTPUT INTERFACE
52 Enter Setup 1664 Barcode Scanner User Guide  2.1 BLUETOOTH® HID For Bluetooth® HID, refer to Chapter 3 – Setting up a WPAN Connection for related connection settings. Run any text editor on your computer, and the scanned data will be transmitted to the computer.  HID Settings  Defaults Keyboard Type  PCAT (US) Alphabets Layout  Normal Digits Layout  Normal Capital Lock Type  Normal Capital Lock State  Off Alphabets Transmission  Case-sensitive Digits Transmission  Alphanumeric keypad Kanji Transmission   Disable Inter-Character Delay  0 (ms) Inter-Function Delay  0 (ms)
    53 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.1.1 ACTIVATE BLUETOOTH® HID & SELECT KEYBOARD TYPE When Bluetooth® HID interface is activated, you will have to select a keyboard type to complete this setting. By default, Bluetooth® HID is activated on the scanner, and the keyboard type is set to PCAT (US).    Activate Bluetooth® HID & Select Keyboard Type…1) Read the barcode above to activate Bluetooth® HID and select a keyboard type.  2) Read the “Decimal Value” barcode on page 251. Refer to the table below for the number of desired keyboard type.  3) Read the “Validate” barcode on the same page to complete this setting.  Bluetooth® HID By default, the keyboard type is set to PCAT (US). The following keyboard types are supported —  No.  Keyboard Type  No. Keyboard Type 64  PCAT (US)  71  PCAT (Belgium) 65  PCAT (French)  72  PCAT (Spanish) 66  PCAT (German)  73  PCAT (Portuguese) 67  PCAT (Italy)  74  PS55 A01-2 (Japanese) 68 PCAT (Swedish)  75 User-defined table 69  PCAT (Norwegian)  76  PCAT (Turkish) 70  PCAT (UK)  77  PCAT (Hungarian)
54 Enter Setup 1664 Barcode Scanner User Guide  2.1.2 RESET CONNECTION For Bluetooth® HID, you can only have the scanner connected to one computer at a time. If you want to connect the scanner to another host, you must have it read the “Reset Connection” barcode so that the current connection record will be cleared. Then, the scanner will restart itself automatically. Go through the whole process in 3.2.3 Connect to Dongle to establish a new connection. Refer to 1.18 Hardware Reset.   Reset ConnectionNote: The “Restore System Defaults” barcode will have the current connection record cleared as well.
    55 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.1.3 KEYBOARD SETTINGS  Alphabets Layout  Digits Layout  Capital Lock Type  Capital Lock Setting  Alphabets Transmission  Digits Transmission  Kanji Transmission  Note:  Bluetooth® HID does not support these functions on PDAs – (1) Capital Lock Setting: Auto Detection (2) Digits Transmission: Numeric Key   Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting.  *Normal AZERTY QWERTZNote: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabets Layout and Digits Layout setting must match your keyboard.
56 Enter Setup 1664 Barcode Scanner User Guide  US Keyboard Style – Normal QWERTY layout, which is normally used in western countries.                  Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.  French Keyboard Style – AZERTY French layout; see below for French Keyboard Style.                  Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters.  German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style.                Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.
    57 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options  Description Normal  Depends on the [Shift] key or [Shift Lock] setting Lower Row  For QWERTY or QWERTZ keyboard Upper Row  For AZERTY keyboard   *Normal Upper Row Lower RowNote: This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required.
58 Enter Setup 1664 Barcode Scanner User Guide  Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type  Description Normal Normal type Capital Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys.   *Normal Shift Lock Capital LockCapital Lock State  Description Capital Lock OFF  Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON  Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).  Refer to the Capital Lock Type above. Auto Detection The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).  This setting is not supported on PDAs.   Auto Detect Capital Lock ON
    59 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。  *Capital Lock OFF
60 Enter Setup 1664 Barcode Scanner User Guide  Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only.  Ignore Case *Case-sensitive         Refer to 5.1 Letter Case.
    61 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad.  Numeric Key *Alphanumeric Key                 Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be “ON”. This setting is not supported on PDAs.  Kanji Transmission   Kanji Transmission is supported by the scanner when either Bluetooth® HID or USB HID is selected for the output interface. By Kanji Transmission, when the host computer is running on Japanese Windows O.S., the scanner is able to transmit Japanese characters including the Chinese characters used in modern Japanese writing system. Kanji Transmission is disabled by default. Enable/disable scanner’s Kanji Transmission by reading the following barcodes:  Enable *Disable
62 Enter Setup 1664 Barcode Scanner User Guide  2.1.4 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Character Delay… (*0~254)1) Read the barcode above to specify the inter-character delay.     2) Read the “Decimal Value” barcode on page 251 for the desired inter-character delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting. 2.1.5 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Function Delay… (*0~254)1) Read the barcode above to specify the inter-function delay.       2) Read the “Decimal Value” barcode on page 251 for the desired inter-function delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting.
    63 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.1.6 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host in batch. You may have the scanner read the “By Character” barcode to process data one character at a time.   *Batch Processing By CharacterNote:  “By Character” transmit mode is required when working with iPhone or iPad. 2.1.7 KEYPAD SUPPORT FOR IPHONE/IPAD When the scanner has been successfully connected to iPhone or iPad for data collection, the onscreen keypad of iPhone or iPad will disappear. Have the scanner read the “Use POWER Key to Show or Hide Keypad” barcode in advance. Then, it will allow pressing the [Power/Delete] key to show or hide the onscreen keypad.    *Normal  Use POWER Key to Show or Hide KeypadInstead of using the [Power/Delete] key, also may have the scanner read the following barcode to show or hide the keypad.   Show or Hide KeypadNote: This function only works for          (1) iPhone 4 and 3GS version 4.1 or later, and (2) iPad version 4.2 or later.
64 Enter Setup 1664 Barcode Scanner User Guide  2.2 BLUETOOTH® SPP SLAVE For Bluetooth® SPP Slave, refer to Chapter 3 – Setting up a WPAN Connection for related connection settings. 2.2.1 ACTIVATE BLUETOOTH® SPP SLAVE MODE This is SPP Slave Mode.   Activate Bluetooth® SPP, Slave Mode2.2.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Function Delay… (*0~254)1) Read the barcode above to specify the inter-function delay.       2) Read the “Decimal Value” barcode on page 251 for the desired inter-function delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting.
    65 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.2.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur.   ACK/NAK Time-out after … (*0~99)1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host.             2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 1 second.  3) Read the “Validate” barcode on the same page to complete this setting.  ACK/NAK Error Beep  Enable Error Beep *Disable Error BeepNote: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data.
66 Enter Setup 1664 Barcode Scanner User Guide  2.3 BLUETOOTH® SPP MASTER As a SPP master device, the scanner will be able to resume connection with the host upon powering on again, as long as the host application is running. If the scanner fails to resume connection, it will try every 5 seconds to re-connect to the host unless you have the scanner read the “Reset Connection” or “Restore System Defaults” barcode. For Bluetooth® SPP Master, refer 3.2.2 Configure Related Settings for related connection settings. Note: In SPP Master Mode, scanner has to connect within the specified period of time (2 minutes by default). During the connection, the scanner will into idle mode for saving power. It will automatically turn off when the time is up. Refer to 1.1.2 Auto Power Off & Power-Saving.  2.3.1 ACTIVATE BLUETOOTH® SPP MASTER MODE This is SPP Master Mode.    Activate Bluetooth® SPP, Master ModeHow to connect with the target device? Produce two setup barcodes for the target SPP slave device, just like what we do for 3610.   “Set Connection”  “MAC ID” Note: The “MAC ID” barcode must have a prefix of two characters, either “0x” or “0X”, followed by the real MAC address of the target device. Usage:  1.  Read the “Activate Bluetooth® SPP, Master Mode” barcode above and barcodes for connection settings, such as authentication and preset PIN. Skip this step if no connection settings are desired. 2.  Read the “Set Connection” and “MAC ID” barcodes. The scanner will respond with one beep upon reading each of the barcodes.  Set Connection  Prefix “0X” to target MAC address
    67 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Note: Read the “Set Connection” barcode first, and then the “MAC ID” barcode within 10 seconds.   Instead of producing the “MAC ID” barcode, you may have the scanner read the setup barcodes for entering the MAC address.  Have the scanner read the “Abort” barcode to cancel the operation at any time while reading setup barcodes for the MAC address. If the MAC address has not been completed yet, having the scanner read the “Validate” barcode can cancel the operation as well.  Enter MAC ID in Hexadecimal…Usage:  1.  Read the barcode above. 2.  Read the “Hexadecimal Value” barcode on page 252 for the desired MAC address. 3.  Read the “Validate” barcode on the same page to complete this setting. Exit SPP Master Mode To stop such re-connection, have the scanner read “Reset Connection” or “Restore System Defaults” barcode so that the current connection record (= MAC ID) will be cleared. Then, the scanner will restart itself automatically. Go through the whole process in 3.2.3 Connect to Dongle to establish a new WPAN connection.  Reset Connection
68 Enter Setup 1664 Barcode Scanner User Guide  2.3.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Function Delay… (*0~254) 1) Read the barcode above to specify the inter-function delay.       2) Read the “Decimal Value” barcode on page 251 for the desired inter-function delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting.
    69 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.3.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur.   ACK/NAK Time-out after … (*0~99)1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host.             2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 1 second.  3) Read the “Validate” barcode on the same page to complete this setting.  ACK/NAK Error Beep  Enable Error Beep *Disable Error BeepNote: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data. 2.3.4 SWITCH BETWEEN MASTER/SLAVE MODE After the scanner has established a connection as a SPP slave device, you may have it read the “Activate Bluetooth® SPP, Master Mode” setup barcode to switch to SPP Master Mode. This will result in easy and reliable re-connection, just like connecting with 3610.
70 Enter Setup 1664 Barcode Scanner User Guide  2.4 USB HID VIA 3610 For USB HID, connect 3610 to the USB port of PC, and then connect the scanner to 3610. Run any text editor on a computer, and the scanned data will be transmitted to the computer.  HID Settings  Defaults Keyboard Type  PCAT (US) Digits Layout  Normal Capital Lock Type  Normal Capital Lock State  Off Alphabets Transmission  Case-sensitive Digits Transmission  Alphanumeric keypad Kanji Transmission   Disable Inter-Character Delay  0 (ms) Inter-Function Delay  0 (ms)
    71 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.4.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE When USB HID interface is activated, you will have to select a keyboard type to complete this setting.    Activate  3610 USB HID & Select Keyboard Type…1) Read the barcode above to activate USB HID and select a keyboard type.  2) Read the “Decimal Value” barcode on page 251. Refer to the table below for the number of desired keyboard type.  3) Read the “Validate” barcode on the same page to complete this setting.  USB HID By default, the keyboard type is set to PCAT (US). The following keyboard types are supported —  No.  Keyboard Type  No. Keyboard Type 64  PCAT (US)  71  PCAT (Belgium) 65  PCAT (French)  72  PCAT (Spanish) 66  PCAT (German)  73  PCAT (Portuguese) 67  PCAT (Italy)  74  PS55 A01-2 (Japanese) 68 PCAT (Swedish)  75 User-defined table 69  PCAT (Norwegian)  76  PCAT (Turkish) 70  PCAT (UK)  77  PCAT (Hungarian)
72 Enter Setup 1664 Barcode Scanner User Guide  2.4.2 KEYBOARD SETTINGS  Alphabets Layout   Digits Layout  Capital Lock Type  Capital Lock Setting  Alphabets Transmission  Digits Transmission  Kanji Transmission   Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting.  *Normal AZERTY QWERTZNote: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabets Layout and Digits Layout setting must match your keyboard.
    73 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 US Keyboard Style – Normal QWERTY layout, which is normally used in western countries.                  Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.  French Keyboard Style – AZERTY French layout; see below for French Keyboard Style.                  Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters.  German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style.                Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.
74 Enter Setup 1664 Barcode Scanner User Guide  Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options  Description Normal  Depends on the [Shift] key or [Shift Lock] setting Lower Row  For QWERTY or QWERTZ keyboard Upper Row  For AZERTY keyboard   *Normal Upper Row Lower RowNote: This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required.
    75 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type  Description Normal Normal type Capital Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys.   *Normal Shift Lock Capital LockCapital Lock State  Description Capital Lock OFF  Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON  Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).  Refer to the Capital Lock Type above. Auto Detection The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).   Auto Detect Capital Lock ON
76 Enter Setup 1664 Barcode Scanner User Guide   *Capital Lock OFF
    77 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only.  Ignore Case *Case-sensitive       Refer to 5.1 Letter Case.
78 Enter Setup 1664 Barcode Scanner User Guide  Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad.  Numeric Key *Alphanumeric Key                 Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be "ON".   Kanji Transmission Kanji Transmission is supported by the scanner when either Bluetooth® HID or USB HID is selected for the output interface. By Kanji Transmission, when the host computer is running on Japanese Windows O.S., the scanner is able to transmit Japanese characters including the Chinese characters used in modern Japanese writing system. Kanji Transmission is disabled by default. Enable/disable scanner’s Kanji Transmission by reading the following barcodes:  Enable *Disable
    79 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.4.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Character Delay… (*0~254)1) Read the barcode above to specify the inter-character delay.     2) Read the “Decimal Value” barcode on page 251 for the desired inter-character delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting. 2.4.4 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Function Delay… (*0~254)1) Read the barcode above to specify the inter-function delay.       2) Read the “Decimal Value” barcode on page 251 for the desired inter-function delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting.
80 Enter Setup 1664 Barcode Scanner User Guide  2.4.5 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host in batch. You may have the scanner read the “By Character” barcode to process data one character at a time.   *Batch Processing By Character
    81 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.5 USB VIRTUAL COM VIA 3610 Connect 3610 to the USB port of PC, and then connect the scanner to 3610. May run HyperTerminal.exe on a computer, and the scanned data will be transmitted to the computer.  Note:  If you are using USB Virtual COM for the first time, you must install its driver from the CD-ROM. Driver version 5.3 or later is required. Please remove older versions! 2.5.1 ACTIVATE USB VIRTUAL COM  Activate 3610  USB Virtual COM2.5.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Function Delay… (*0~254)1) Read the barcode above to specify the inter-function delay.       2) Read the “Decimal Value” barcode on page 251 for the desired inter-function delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting.
82 Enter Setup 1664 Barcode Scanner User Guide  2.5.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur.   ACK/NAK Time-out after … (*0~99)1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host.             2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 1 second.  3) Read the “Validate” barcode on the same page to complete this setting.  ACK/NAK Error Beep  Enable Error Beep *Disable Error BeepNote: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data.
    83 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.6 DIRECT USB HID   1664 supports “Direct” USB HID interface for memory mode. Use the provided USB cable to connect 1664 to the USB port of PC. Run any text editor on a computer, and the scanned data will be transmitted to the computer. Refer to 1.2.2 Memory Mode.  HID Settings  Defaults Keyboard Type  HID PCAT (US) Digits Layout  Normal Capital Lock Type  Normal Capital Lock State  OFF Alphabets Transmission  Case Sensitive Digits Transmission  Alphanumeric Keypad Kanji Transmission   Disable Alphabets Layout  Normal Inter-Character Delay  0 (ms) Inter-Function Delay  0 (ms)
84 Enter Setup 1664 Barcode Scanner User Guide  2.6.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE When USB HID interface is activated, please select a keyboard type to complete this setting.    Activate  Direct USB HID & Select Keyboard Type…1) Read the barcode above to activate USB HID and select a keyboard type.  2) Read the “Decimal Value” barcode page 251 . Refer to the table below for the number of desired keyboard type.  3) Read the “Validate” barcode on the same page to complete this setting.  USB HID By default, the keyboard type is set to PCAT (US). The following keyboard types are supported —  No.  Keyboard Type  No. Keyboard Type 64  HID PCAT (US)  71  HID PCAT (Belgium) 65  HID PCAT (French)  72  HID PCAT (Spanish) 66  HID PCAT (German)  73  HID PCAT (Portuguese) 67  HID PCAT (Italy)  74  HID A01-2 (Japanese) 68  HID PCAT (Swedish)  75  User-Defined Table 69  HID PCAT (Norwegian)  76  HID PCAT (Turkish) 70  HID PCAT (UK)  77  HID PCAT (Hungarian)
    85 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.6.2 KEYBOARD SETTINGS  Alphabets Layout   Digits Layout  Capital Lock Type  Capital Lock Setting  Alphabets Transmission  Digits Transmission  Kanji Transmission    Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting.  *Normal AZERTY QWERTZNote: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabets Layout and Digits Layout setting must match using keyboard.
86 Enter Setup 1664 Barcode Scanner User Guide  US Keyboard Style – Normal QWERTY layout, which is normally used in western countries.                  Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.  French Keyboard Style – AZERTY French layout; see below for French Keyboard Style.                  Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters.  German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style.                Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.
    87 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options  Description Normal  Depends on the [Shift] key or [Shift Lock] setting Lower Row  For QWERTY or QWERTZ keyboard Upper Row  For AZERTY keyboard   *Normal Upper Row Lower RowNote: This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required.
88 Enter Setup 1664 Barcode Scanner User Guide  Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type  Description Normal Normal type Capital Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock  When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys.   *Normal Shift Lock Capital LockCapital Lock State  Description Capital Lock OFF  Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON  Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).  Refer to the Capital Lock Type above. Auto Detection The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission).   Auto Detect Capital Lock ON
    89 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。  *Capital Lock OFF
90 Enter Setup 1664 Barcode Scanner User Guide  Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only.  Ignore Case *Case-sensitive       Refer to 5.1 Letter Case.
    91 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if want to use the keys on the numeric keypad.  Numeric Key *Alphanumeric Key                 Note: If selecting “Numeric Keypad”, the Num Lock status of the physical keyboard should be "ON".   Kanji Transmission   Kanji Transmission is supported by the scanner when either Bluetooth® HID or USB HID is selected for the output interface. By Kanji Transmission, when the host computer is running on Japanese Windows O.S., the scanner is able to transmit Japanese characters including the Chinese characters used in modern Japanese writing system. Kanji Transmission is disabled by default. Enable/disable scanner’s Kanji Transmission by reading the following barcodes:  Enable *Disable
92 Enter Setup 1664 Barcode Scanner User Guide  2.6.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Character Delay… (*0~254)1) Read the barcode above to specify the inter-character delay.     2) Read the “Decimal Value” barcode on page 251 for the desired inter-character delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting. 2.6.4 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Function Delay… (*0~254)1) Read the barcode above to specify the inter-function delay.       2) Read the “Decimal Value” barcode on page 251 for the desired inter-function delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting.
    93 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.6.5 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host in batch, or use the scanner to read the “By Character” barcode to process data one character at a time.  *Batch Processing By Character
94 Enter Setup 1664 Barcode Scanner User Guide  2.7 DIRECT USB VIRTUAL COM 1664 support “Direct” USB Virtual COM interface for memory mode. Use the provided USB cable to connect 1664 to the USB port of PC. May run HyperTerminal.exe on a computer, and the scanned data will be transmitted to the computer. Refer to 1.2.2 Memory Mode. Note: If using USB Virtual COM for the first time, it must install its driver from the CD-ROM. Driver version 5.3 or later is required. Please remove older versions! 2.7.1 ACTIVATE USB VIRTUAL COM  *Activate Direct USB  Virtual COM2.7.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be.   Inter-Function Delay… (*0~254)1) Read the barcode above to specify the inter-function delay.       2) Read the “Decimal Value” barcode on page 251 for the desired inter-function delay (millisecond).  3) Read the “Validate” barcode on the same page to complete this setting.
    95 Update  Chapter 2  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 2.7.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur.   ACK/NAK Time-out after … (*0~99)1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host.             2) Read the “Decimal Value” barcode on page 251. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 1 second.  3) Read the “Validate” barcode on the same page to complete this setting.  ACK/NAK Error Beep  Enable Error Beep *Disable Error BeepNote: It suggests enabling the error beep so that the issue has notified of such data loss and has the scanner re-read data.
96 Enter Setup 1664 Barcode Scanner User Guide
    97 Update  The scanner can be configured to send data to a host computer wirelessly via the 3610 dongle, or to a notebook computer or PDA with Bluetooth® wireless technology. Upon powering up, the scanner will be ready for establishing a WPAN connection.  To establish a connection via 3610 after reading “Set Connection” and “Serial No.” labels …     Interface Option  Reference USB HID  2.4 USB HID via 3610 USB Virtual COM  2.5 USB Virtual COM via 3610  To establish a connection via Bluetooth® dongle after pairing… Interface Option  Reference Bluetooth® HID  2.1 Bluetooth® HID Bluetooth® SPP  2.2  Bluetooth® SPP Slave, 2.3 Bluetooth® SPP Master   IN THIS CHAPTER 3.1 Connecting via 3610 .................................................. 98 3.2 Connecting via Bluetooth® Dongle ............................... 101  Chapter 3 SETTING UP A WPAN CONNECTION
98 Enter Setup 1664 Barcode Scanner User Guide  3.1 CONNECTING VIA 3610 By default, the interface of 3610 is set to “USB HID”. Use the interface cable to connect the scanner via 3610 to PC. You can have up to seven scanners connected to one computer at the same time. Note:  If you are using USB Virtual COM for the first time, you must install its driver from the CD-ROM. Driver version 5.3 or later is required. Please remove older versions! 3.1.1 CONNECT TO 3610 Connect any scanner to 3610 by having the scanner read the two labels at the back of 3610. The scanner will respond with one beep upon reading each of the labels.  “Set Connection” label  “Serial Number” label After reading these labels, the scanner will stay active for a specified period of time (2 minutes by default) trying to connect to the 3610 stand while its LED is flashing blue (On/Off ratio 0.5 s: 0.5 s). Once connected, the scanner will respond with three beeps (tone ascending from low to high), and the LED becomes flashing blue (On/Off ratio 0.02 s: 3 s). When getting out of range, the scanner will respond with three short beeps (tone descending from high to low). Read the “Set Connection” label first, and then the “Serial Number” label. If the “Set Connection” label on 3610 is illegible, try this one —   Set ConnectionNote:  The 3610 settings will overwrite the interface-related settings on the scanners that are currently connected to 3610.
    99 Update  Chapter 3  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 3.1.2 CHANGE INTERFACE If want to change the interface 3610, use one of the connected scanners to configure the interface-related settings and it will pass the new settings to 3610, which will then initialize and pass the settings to any other connected scanners. 1) Have the scanners read the “Set Connection” and “Serial Number” labels at the back of 3610. 2) Within two minutes, connect 3610 to the USB port of PC. For USB Virtual COM, it may need to install its driver first! 3) The scanners will connect to the computer via 3610. 4) Have one scanner read the “Enter Setup” barcode to enter the configuration mode. 5) Have the scanner read the desired interface barcode and configure its related settings –   “Activate USB HID & Select Keyboard Type”  “Activate USB Virtual COM” 6) Have the scanner read the “Update” barcode to exit the configuration mode. 7) After the scanner resumes connection with 3610, it will pass the interface-related settings to 3610. 8) Upon receipt of the new settings, 3610 will initialize itself. 9) Updated with new settings, 3610 will pass the settings to other connected scanners.
100 Enter Setup 1664 Barcode Scanner User Guide  3.1.3 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enabled, meaning the scanner will listen to the wireless network at a reduced rate.  *Enable Disable
    101 Update  Chapter 3  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 3.2 CONNECTING VIA BLUETOOTH® DONGLE 3.2.1 CHANGE INTERFACE Below is the procedure to configure the scanner before establishing a WPAN connection via Bluetooth® dongle. 1) Have the scanner read the “Enter Setup” barcode to enter the configuration mode. 2) Have the scanner read the desired interface barcode –   “Activate Bluetooth® HID & Select Keyboard Type”  “Activate Bluetooth® SPP Slave Mode”  “Activate Bluetooth® SPP Master Mode” 3) Have the scanner read the barcodes related to WPAN settings, such as Device Name Broadcasting, Authentication & PIN Code, etc. 4) Have the scanner read the “Update” barcode to exit the configuration mode. 5) The scanner will stay active for a specified period of time (2 minutes by default) waiting for a connection request from the host (SPP Slave Mode) or trying to connect to the host (HID or SPP Master Mode). Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio 0.5 s: 0.5 s). Once connected, when getting out of range, the scanner will respond with three short beeps (tone descending from high to low).
102 Enter Setup 1664 Barcode Scanner User Guide  3.2.2 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enabled, meaning the scanner will listen to the wireless network at a reduced rate.  *Enable DisableNote: When connecting more than two scanners to a notebook computer or PDA with Bluetooth® wireless technology, we suggest that you disable the power-saving setting for a more reliable connection.  Device Name Broadcasting The scanner can be configured to hide itself from other devices equipped with Bluetooth® wireless technology. Simply disable the device name broadcasting setting so that it won’t be discovered by any other computer or PDA. However, broadcasting must be enabled for establishing an initial connection with the scanner. For example, disable device name broadcasting after successfully connecting the scanner to WorkStation1. Such connection will be maintained automatically unless the scanner is removed from the paired device list (called unpairing) by WorkStation1 or any changes made to authentication and the PIN code. If want WorkStation2 to connect to the scanner, it have to enable device name broadcasting first.  *Enable DisableNote: By default, device name broadcasting is enabled (which is required for initial connection).
    103 Update  Chapter 3  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Authentication When any changes are made to authentication and PIN code on the scanner side, you will have to remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. The scanner allows up to 16 characters for a PIN code and provides two options for authentication: Enable Authentication with Preset PIN Have the scanner read the “Use preset PIN” barcode, and change the preset PIN if necessary. This means you will have to enter exactly the same string for your computer or PDA to connect to the scanner. If the PIN or passkey is incorrect, any connection attempt will be turned down by the scanner. See step 8 in 3.2.3 Connect to Dongle. 1.  Read the “Use preset PIN” barcode to enable authentication with a preset PIN.  Use Preset PIN2.  Read one of the barcodes to specify the PIN code, in decimal or hexadecimal. By default, the PIN code is set to “0000”. Maximum 16 characters are allowed.  Enter PIN in Hexadecimal … Enter PIN in Decimal…3.  Read the “Decimal Value” barcode on page 251 or the “Hexadecimal Value” barcode on page 252 for the desired digits or character string. Read the “Clear PIN Code” barcode first if you need to re-input the PIN code.  Clear PIN Code4.  Read the “Validate” barcode to complete this setting. Enable Authentication with Random PIN or No Authentication By default, it is set to “No PIN or use random PIN”, which depends on the setting of the target device. (No PIN = No authentication.)  *No PIN or  use random PIN
104 Enter Setup 1664 Barcode Scanner User Guide                 Note: When using Bluetooth® HID, some device driver may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to “No PIN or use random PIN” before pairing. While pairing, the host PIN code will be displayed on the computer screen. Have the scanner read the setup barcode “Enter PIN Code in Decimal” or “Enter PIN Code in Hexadecimal” to input the matching PIN code. Refer to Disable Authentication or Use Random PIN.              Use random PINNo PIN required
    105 Update  Chapter 3  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 3.2.3 CONNECT TO DONGLE The procedure goes through associating devices for establishing a WPAN connection, which is pretty much the same except for the software you are using. If your computer is running Microsoft® Windows® XP Service Pack 3 (SP3) or Windows Vista® Service Pack 1 (SP1), you can use the software support that Windows® includes, or you can use the driver that the device manufacturer provides. Now, let’s try using the software support that Windows® XP Service Pack 2 includes.  Bluetooth® HID Procedure By default, Bluetooth® HID is activated on the scanner, and the keyboard type is set to PCAT (US). When Bluetooth® HID is re-activated, you will have to select a keyboard type to complete this setting. The procedure is the same as for Bluetooth® SPP. Refer to steps 1~11 below. Bluetooth® SPP Procedure 1.  Turn on the Bluetooth® function on your computer, running Windows XP SP2. 2.  Double-click the Bluetooth® icon from the lower right of the taskbar.   Alternatively, you may go to Control Panel > Bluetooth Devices. 3.  Click [Add] to search devices nearby.
106 Enter Setup 1664 Barcode Scanner User Guide  4.  Turn on the scanner with correct WPAN settings, such as select Bluetooth® SPP or Bluetooth® HID, broadcasting enabled, authentication enabled, and PIN code specified, etc. Select the check box of [My device is set up and ready to be found] on your computer. 5. Click [Next].    6.  Wait for a few seconds for the Wizard to search available devices nearby. The scanner will appear with its “serial number” as the device name. You may double-check the “Serial Number” label on the scanner to ensure connecting with the correct scanner. Select the target scanner. If the target scanner does not appear on the list, click [Search Again] to refresh the list. The scanner might enter Suspend Mode now, and you can press the trigger to have it active again (=discoverable). It will then stay active for a specified period of time (2 minutes by default) and wait for PC to establish a connection.
    107 Update  Chapter 3  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 7. Click [Next].  8.  Enter the passkey for authentication, which must be exactly the same as configured for the scanner.
108 Enter Setup 1664 Barcode Scanner User Guide  9.  Click [Next]. Wait for a few seconds for Windows to exchange passkeys.
    109 Update  Chapter 3  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Note: When Bluetooth security is enabled without providing a pre-set PIN code, dynamic input of PIN code is supported. 10. Click [Finish].                             1664 as Bluetooth® SPP Slave1664 as Bluetooth® SPP Master
110 Enter Setup 1664 Barcode Scanner User Guide  11.  Now the target scanner will be listed as shown below. You can have up to seven scanners connected to one computer at the same time.  Note: When any changes are made to authentication and PIN code on the scanner side, or you want to change to use Bluetooth® HID, it is suggested that you remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. 12.  Run the desired application on your computer, such as HyperTerminal.exe if using Bluetooth® SPP or Notepad.exe if using Bluetooth® HID. The status of the scanner listed on the device list will be updated to “Connected”, indicating the WPAN connection is established successfully via the outgoing COM port if using Bluetooth® SPP. Note: Even though the scanner is connected to the host with authentication disabled (= no PIN code required), the host may still request a PIN code while the application is opening COM port. Dynamic input of PIN code is supported so that you may input a matching PIN code on the scanner. Refer to Disable Authentication or Use Random PIN. Select and Remove
    111 Update  Chapter 3  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。      Bluetooth®SPP Connected Bluetooth®SPP Disconnected
112 Enter Setup 1664 Barcode Scanner User Guide
    113 Update  In this chapter, a brief on the symbology settings is provided for your reference.   IN THIS CHAPTER 4.1 Codabar .................................................................. 114 4.2 Code 25 – Industrial 25 ............................................. 116 4.3 Code 25 – Interleaved 25 ........................................... 118 4.4 Code 25 – Matrix 25 .................................................. 121 4.5 Code 25 – Chinese 25 ............................................... 123 4.6 Italian Pharmacode (Code 32)  ................................... 124 4.7 Code 39 .................................................................. 125 4.8 Trioptic Code 39 ....................................................... 128 4.9 Code 93 .................................................................. 129 4.10 Code 128 ............................................................... 131 4.11 GS1-128 (EAN-128)  ............................................... 132 4.12 ISBT 128 ............................................................... 133 4.13 GS1 DataBar (RSS Family) ....................................... 135 4.14 MSI ....................................................................... 140 4.15 EAN-8 ................................................................... 142 4.16 EAN-13 .................................................................. 143 4.17 UCC Coupon Extended Code ..................................... 145 4.18 UPC-A ................................................................... 146 4.19 UPC-E ................................................................... 148 4.20 Code 11 ................................................................. 151 4.21 Composite Code ...................................................... 153 4.22 US Postal Code ....................................................... 155 4.23 UK Postal Code ....................................................... 156 4.24 More Postal Code .................................................... 157 4.25 2D Symbologies ...................................................... 159 4.26 Macro PDF ............................................................. 162   Chapter 4 CHANGING SYMBOLOGY SETTINGS
114 Enter Setup 1664 Barcode Scanner User Guide  4.1 CODABAR  *Enable Disable4.1.1 START/STOP TRANSMISSION Decide whether to include the start/stop characters in the data being transmitted.   Transmit Start/Stop Characters *Do Not Transmit4.1.2 CLSI CONVERSION When enabled, the CLSI editing strips the start/stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar barcode.   Apply CLSI Editing *Do Not ApplyNote:  The 14-character barcode length does not include start/stop characters.
    115 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.1.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.  If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified. Note:   The specified length(s) must include the check digit(s) the barcode contains.  1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.   *Enable Max./Min. Length (1~55)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.   Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 251 for the desired length.  4) Read the “Validate” barcode on the same page to complete this setting.
116 Enter Setup 1664 Barcode Scanner User Guide  4.2 CODE 25 – INDUSTRIAL 25  *Enable Disable
    117 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.2.1 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.  If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified. Note:   The specified length(s) must include the check digit(s) the barcode contains.  1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.   *Enable Max./Min. Length (1~55)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.   Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 251 for the desired length.  4) Read the “Validate” barcode on the same page to complete this setting.
118 Enter Setup 1664 Barcode Scanner User Guide  4.3 CODE 25 – INTERLEAVED 25  *Enable Disable4.3.1 VERIFY CHECK DIGIT Decide whether to verify the check digit. When desired, select one of the algorithms, USS or OPCC. If incorrect, the barcode will not be accepted.   *Do Not Verify USS Check Digit OPCC Check Digit4.3.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.   *Transmit Interleaved 25  Check Digit Do Not Transmit
    119 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.3.3 CONVERT TO EAN-13 Decide whether to convert a 14-character barcode into EAN-13 if the following requirements are met:  The barcode must have a leading 0 and a valid EAN-13 check digit.  “Verify Check Digit” must be disabled.   Convert to EAN-13 *Do Not Convert
120 Enter Setup 1664 Barcode Scanner User Guide  4.3.4 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.  If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified. Note:   The specified length(s) must include the check digit(s) the barcode contains.  1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.   *Enable Max./Min. Length (1~55)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.   Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 251 for the desired length.  4) Read the “Validate” barcode on the same page to complete this setting.
    121 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.4 CODE 25 – MATRIX 25  Enable *Disable4.4.1 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted.   Verify Matrix 25 Check Digit *Do Not Verify4.4.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.   *Transmit Matrix 25 Check Digit Do Not Transmit
122 Enter Setup 1664 Barcode Scanner User Guide  4.4.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.  If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified. Note:   The specified length(s) must include the check digit(s) the barcode contains.  1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.   *Enable Max./Min. Length (1~55)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.   Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 251 for the desired length.  4) Read the “Validate” barcode on the same page to complete this setting.
    123 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.5 CODE 25 – CHINESE 25  Enable *Disable
124 Enter Setup 1664 Barcode Scanner User Guide  4.6 ITALIAN PHARMACODE (CODE 32)  Enable *DisableNote:  Code 39 must be enabled first.
    125 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.7 CODE 39  *Enable Disable4.7.1 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted.   Verify Code 39  Check Digit *Do Not Verify4.7.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.   *Transmit Code 39 Check Digit Do Not Transmit
126 Enter Setup 1664 Barcode Scanner User Guide  4.7.3 STANDARD/FULL ASCII CODE 39 Decide whether to support Code 39 Full ASCII that includes all the alphanumeric and special characters.   Code 39 Full ASCII *Standard Code 39Note:  Trioptic Code 39 and Code 39 Full ASCII cannot be enabled at the same time.
    127 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.7.4 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.  If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified. Note:   The specified length(s) must include the check digit(s) the barcode contains.  1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.   *Enable Max./Min. Length (1~55)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.   Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 251 for the desired length.  4) Read the “Validate” barcode on the same page to complete this setting.
128 Enter Setup 1664 Barcode Scanner User Guide  4.8 TRIOPTIC CODE 39 Decide whether to decode Trioptic Code 39.  Trioptic Code 39 is a variant of Code 39 used in the marking of computer tap cartridges. It always contains six characters.   Enable  *DisableNote:  Trioptic Code 39 and Code 39 Full ASCII cannot be enabled at the same time.
    129 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.9 CODE 93  *Enable Disable
130 Enter Setup 1664 Barcode Scanner User Guide  4.9.1 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.  If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified. Note:   The specified length(s) must include the check digit(s) the barcode contains.  1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.   *Enable Max./Min. Length (1~55)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.   Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 251 for the desired length.  4) Read the “Validate” barcode on the same page to complete this setting.
    131 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.10 CODE 128  *Enable Disable
132 Enter Setup 1664 Barcode Scanner User Guide  4.11 GS1-128 (EAN-128)  *Enable DisableNote:  GS1-128 barcodes can be decoded only when this setting is enabled. 4.11.1 TRANSMIT CODE ID Decide whether to include the Code ID (“]C1”) in the data being transmitted.   Transmit GS1-128 Code ID *Do Not Transmit4.11.2 FIELD SEPARATOR (GS CHARACTER) Decide whether to apply a field separator (to convert the FNC1 control character to human readable character).   Enable Field Separator…1) Read the barcode above to enable field separator. 2) Read the “Hexadecimal Value” barcode on page 252 for the desired character string.  3) Read the “Validate” barcode to complete this setting. Note: GS1-128 barcodes start with the FNC1 control character to distinguish themselves from other uses of Code 128. FNC1 is also used to separate data fields in the GS1-128 barcodes.
    133 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.12 ISBT 128  *Enable Disable4.12.1 ISBT CONCATENATION Decide whether to decode and concatenate pairs of ISBT barcodes.  Disable ISBT Concatenation It will not concatenate pairs of ISBT barcodes it encounters.  Enable ISBT Concatenation There must be two ISBT barcodes in order for the scanner to decode and perform concatenation. It does not decode single ISBT barcodes.  Auto-discriminate ISBT Concatenation It decodes and concatenates pairs of ISBT barcodes immediately. If only a single ISBT barcode is present, the scanner must decode 10 times before transmitting its data to confirm that there is no additional ISBT barcode.   Disable Enable *Auto-discriminate
134 Enter Setup 1664 Barcode Scanner User Guide  4.12.2 ISBT CONCATENATION REDUNDANCY Specify the concatenation redundancy (2~20 times) when ISBT concatenation is enabled.   ISBT Concatenation Redundancy 2~20 (*10)1) Read the barcode above to specify the concatenation redundancy. 2) Read the “Decimal Value” barcode on page 251 for the desired redundancy.  3) Read the “Validate” barcode on the same page to complete this setting.
    135 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.13 GS1 DATABAR (RSS FAMILY) It is categorized into three groups:  Group I — GS1 DataBar Omnidirectional (RSS-14) This group consists of the following:    GS1 DataBar Omnidirectional  GS1 DataBar Truncated   GS1 DataBar Stacked  GS1 DataBar Stacked Omnidirectional Group II — GS1 DataBar Expanded (RSS Expanded) This group consists of the following:    GS1 DataBar Expanded  GS1 DataBar Expanded Stacked Group III — GS1 DataBar Limited (RSS Limited) This group consists of the following:    GS1 DataBar Limited 4.13.1 SELECT CODE ID Select a desired Code ID to use:  “]e0“  (GS1 DataBar Code ID)  “]C1” (GS1-128 Code ID)   Use “]C1” *Use “]e0”
136 Enter Setup 1664 Barcode Scanner User Guide  4.13.2 GS1 DATABAR OMNIDIRECTIONAL (RSS-14)  Enable RSS-14 &  RSS Expanded(Groups I, II) *Disable The settings below apply to Group I symbologies only:  GS1 DataBar Omnidirectional  GS1 DataBar Truncated  GS1 DataBar Stacked  GS1 DataBar Stacked Omnidirectional  Transmit Code ID Decide whether to include the Code ID in the data being transmitted.  *Transmit RSS-14 Code ID Do Not TransmitTransmit Application ID Decide whether to include the Application ID ("01") in the data being transmitted.  *Transmit RSS-14 Application ID Do Not Transmit
    137 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.13.3 GS1 DATABAR EXPANDED (RSS EXPANDED)  Enable RSS-14 &  RSS Expanded(Groups I, II) *Disable The settings below apply to Group II symbologies only:  GS1 DataBar Expanded  GS1 DataBar Expanded Stacked  Transmit Code ID Decide whether to include the Code ID in the data being transmitted.  *Transmit  RSS Expanded Code ID Do Not Transmit
138 Enter Setup 1664 Barcode Scanner User Guide  4.13.4 GS1 DATABAR LIMITED (RSS LIMITED)  Enable RSS Limited(Group III) *DisableTransmit Code ID Decide whether to include the Code ID in the data being transmitted.  *Transmit  RSS Limited Code ID Do Not TransmitTransmit Application ID Decide whether to include the Application ID ("01") in the data being transmitted.  *Transmit  RSS Limited Application ID Do Not Transmit
    139 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.13.5 CONVERT TO UPC/EAN This only applies to GS1 DataBar Omnidirectional and GS1 DataBar Limited barcodes not decoded as part of a Composite barcode.  Convert to EAN-13: It will strip the leading “010” from barcodes.  “01” is the Application ID and must be followed by a single zero (the first digit encoded).  Convert to UPC-A: It will strip the leading “0100” from barcodes.  “01” is the Application ID and must be followed by two or more zeros (but not six zeros).   Convert to UPC/EAN *Do Not Convert
140 Enter Setup 1664 Barcode Scanner User Guide  4.14 MSI  Enable *Disable4.14.1 VERIFY CHECK DIGIT Select one of the three calculations to verify check digit(s) when decoding barcodes. If incorrect, the barcode will not be accepted.   *Single Modulo 10 Double Modulo 10 Modulo 10 & 114.14.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit(s) in the data being transmitted.   *Last Digit Not Transmitted Both Digits Transmitted Both Digits  Not Transmitted
    141 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.14.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.   If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified. Note:   The specified length(s) must include the check digit(s) the barcode contains.  1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.   *Enable Max./Min. Length (1~55)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.   Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 251 for the desired length.  4) Read the “Validate” barcode on the same page to complete this setting.
142 Enter Setup 1664 Barcode Scanner User Guide  4.15 EAN-8 EAN-8  *Enable EAN-8  (No Addon) DisableEAN-8 Addon 2  Enable EAN-8 Addon 2 *DisableEAN-8 Addon 5  Enable EAN-8 Addon 5 *Disable
    143 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.16 EAN-13 EAN-13  *Enable EAN-13  (No Addon) DisableEAN-13 Addon 2  Enable EAN-13 Addon 2 *DisableEAN-13 Addon 5  Enable EAN-13 Addon 5 *Disable
144 Enter Setup 1664 Barcode Scanner User Guide  4.16.1 CONVERT TO ISBN Decide whether to convert the EAN-13 barcode, starting with 978 and 979, to ISBN.   Convert EAN-13 to ISBN *Do Not Convert4.16.2 CONVERT TO ISSN Decide whether to convert the EAN-13 barcode, starting with 977 to ISSN.   Convert EAN-13 to ISSN *Do Not Convert
    145 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.17 UCC COUPON EXTENDED CODE Decide whether to decode the following barcodes as Coupon Code.  UPC-A barcodes starting with digit “5”  EAN-13 barcodes starting with digits “99”  UPC-A/EAN-128 Coupon Codes   Enable *DisableNote:   Depending on your requirements, UPC-A, EAN-13 and EAN-128 must be enabled first!
146 Enter Setup 1664 Barcode Scanner User Guide  4.18 UPC-A UPC-A  *Enable UPC-A  (No Addon) DisableUPC-A Addon 2  Enable UPC-A Addon 2 *DisableUPC-A Addon 5  Enable UPC-A Addon 5 *Disable
    147 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.18.1 TRANSMIT SYSTEM NUMBER Decide whether to include the system number in the data being transmitted.   *Transmit UPC-A System Number Do Not Transmit4.18.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.   *Transmit UPC-A Check Digit Do Not Transmit
148 Enter Setup 1664 Barcode Scanner User Guide  4.19 UPC-E UPC-E  *Enable UPC-E  (No Addon) DisableUPC-E Addon 2  Enable UPC-E Addon 2 *DisableUPC-E Addon 5  Enable UPC-E Addon 5 *Disable
    149 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.19.1 SELECT SYSTEM NUMBER Decide whether to decode the ordinary UPC-E barcodes only or both UPC-E0 and UPC-E1 barcodes.  System number 0 enabled for decoding UPC-E0 barcodes.  System number 1 enabled for decoding UPC-E1 barcodes.   System Number 0 & 1 *System Number 0 OnlyWarning:  Because of the way system number 1 is encoded, if both system numbers are enabled, the user might suffer from short scanning UPC-A or EAN-13 barcodes into UPC-E1 barcodes. 4.19.2 CONVERT TO UPC-A Decide whether to expand the read UPC-E barcode, as well as its addons, into UPC-A.   After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g. System Number, Check Digit).   Convert UPC-E to UPC-A *Do Not Convert
150 Enter Setup 1664 Barcode Scanner User Guide  4.19.3 TRANSMIT SYSTEM NUMBER Decide whether to include the system number in the data being transmitted.   Transmit UPC-E System Number *Do Not Transmit4.19.4 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.   *Transmit UPC-E Check Digit Do Not Transmit
    151 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.20 CODE 11  Enable *Disable4.20.1 VERIFY CHECK DIGIT Decide whether to verify the check digit(s). If incorrect, the barcode will not be accepted.   Verify One  Check Digit Verify Two  Check Digit *Do Not Verify4.20.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit(s) in the data being transmitted.   Transmit Code 11 Check Digit *Do Not TransmitNote:   "Verify Check Digit" must be enabled first.
152 Enter Setup 1664 Barcode Scanner User Guide  4.20.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length.   If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified.  If “Fixed Length” is selected, up to 2 fixed lengths can be specified. Note:   The specified length(s) must include the check digit(s) the barcode contains.  1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.   *Enable Max./Min. Length (1~55)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2.   Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 251 for the desired length.  4) Read the “Validate” barcode on the same page to complete this setting.
    153 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.21 COMPOSITE CODE 4.21.1 COMPOSITE CC-A/B  Enable Composite CC-A/B *Disable4.21.2 COMPOSITE CC-C  Enable Composite CC-C *Disable4.21.3 COMPOSITE TLC-39  Enable Composite TLC-39 *Disable
154 Enter Setup 1664 Barcode Scanner User Guide  4.21.4 UPC COMPOSITE MODE UPC barcodes can be “linked” with a 2D barcode during transmission as if they were one barcode.  UPC Never Linked Transmit UPC barcodes regardless of whether a 2D barcode is detected.  UPC Always Linked Transmit UPC barcodes and the 2D portion. If the 2D portion is not detected, the UPC barcode will not be transmitted. Note:  CC-A/B or CC-C must be enabled!  Auto-discriminate UPC Composites Transmit UPC barcodes as well as the 2D portion if present.   UPC Never Linked *UPC Always Linked Auto-discriminate4.21.5 GS1-128 EMULATION MODE FOR UCC/EAN COMPOSITE CODES Decide whether to transmit UCC/EAN Composite Code data as if it was encoded in GS1-128 barcodes.   Enable GS1-128 Emulation Mode *Disable
    155 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.22 US POSTAL CODE 4.22.1 US POSTNET  *Enable US Postnet Disable4.22.2 US PLANET  *Enable US Planet Disable4.22.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.   *Transmit US Postal Check Digit Do Not Transmit
156 Enter Setup 1664 Barcode Scanner User Guide  4.23 UK POSTAL CODE 4.23.1 UK POSTAL  *Enable UK Postal Disable4.23.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.   *Transmit UK Postal Check Digit Do Not Transmit
    157 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.24 MORE POSTAL CODE 4.24.1 JAPAN POSTAL  *Enable Japan Postal Disable4.24.2 AUSTRALIAN POSTAL  *Enable Australian Postal Disable4.24.3 DUTCH POSTAL  *Enable Dutch Postal Disable4.24.4 USPS 4CB/ONE CODE/INTELLIGENT MAIL  Enable USPS 4CB/  One Code/ Intelligent Mail *Disable
158 Enter Setup 1664 Barcode Scanner User Guide  4.24.5 UPU FICS POSTAL  Enable UPU FICS Postal *Disable
    159 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.25 2D SYMBOLOGIES 4.25.1 PDF417  *Enable PDF417 Disable4.25.2 MicroPDF417  Enable MicroPDF417 *Disable
160 Enter Setup 1664 Barcode Scanner User Guide  4.25.3 DATA MATRIX  *Enable Data Matrix Disable Data Matrix Mirror Decide whether to decode mirror image Data Matrix barcodes.  Never — do not decode Data Matrix barcodes that are mirror images.  Always — decode only Data matrix barcodes that are mirror images.  Auto — decode both mirrored and unmirrored Data Matrix barcoes.  *Never Always Auto
    161 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.25.4 MAXICODE  *Enable Maxicode Disable4.25.5 QR CODE  *Enable QR Code Disable4.25.6 MicroQR  *Enable MicroQR Disable4.25.7 AZTEC  *Enable Aztec Disable
162 Enter Setup 1664 Barcode Scanner User Guide  4.26 MACRO PDF Macro PDF is a special feature for concatenating multiple PDF barcodes into one file, known as Macro PDF417 or Macro MicroPDF417. Note: When printing barcodes, keep each Macro PDF sequence separate, as each has a unique identifier. Do not mix barcodes from several Macro PDF sequences, even if they encode the same data. When you scan Macro PDF sequences, scan the entire Macro PDF sequence without interruption! 4.26.1 TRANSMIT/DECODE MODE Decide how to handle Macro PDF decoding.  Buffer All Symbols / Transmit Macro PDF When Complete Transmit all decoded data from an entire Macro PDF sequence only when the entire sequence is scanned and decoded. If the decoded data exceeds the limit of 50 symbols, no transmission because the entire sequence was not scanned!  Transmit Any Symbol in Set / No Particular Order Transmit data from each Macro PDF symbol as decoded, regardless of the sequence.  Passthrough All Symbols Transmit and decode all Macro PDF symbols and perform no processing. In this mode, the host is responsible for detecting and parsing the Macro PDF sequences.   Buffer All Symbols /  Transmit When Complete Transmit Any Symbol in Set /  No Particular Order *Passthrough All Symbols
    163 Update  Chapter 4  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 4.26.2 ESCAPE CHARACTERS When enabled, it uses the backslash "\" as an Escape character for systems that can process transmissions containing special data sequences. It will format special data according to the Global Label Identifier (GLI) protocol, which only affects the data portion of a Macro PDF symbol transmission. The Control Header, if enabled, is always sent with GLI formatting.   GLI Protocol *None4.26.3 TRANSMIT CONTROL HEADER The control header contains the segment index and file ID. For example, the field may be “\92800000\725\120\343”. The five digits after the \928 are the segment index (or block index), and \725\120\343 is the file ID.  Enable this when selecting “Transmit Any Symbol in Set/ No Particular Order”.   Disable this when selecting “Buffer All Symbols/Transmit Macro PDF When Complete”.  This option has no effect when selecting "Passthrough All Symbols".   Transmit Control Header *Do Not Transmit
164 Enter Setup 1664 Barcode Scanner User Guide
    165 Update  You may configure in which format the collected data will be output to the host computer. Barcode read by the scanner will be processed in the following sequence –  1) Perform character substitution on the data scanned. 2) Add Code ID and Length Code to the front of the data:[Code ID][Length Code][Data] 3) Process the whole data in step 2 with user formats. Data is now divided into fields by user specified rules. Refer to Chapter 6 Applying Formats for Data Editing. 4) Add  Prefix Code and Suffix Code before transmission:[Prefix Code][Processed Data][Suffix Code] IN THIS CHAPTER 5.1 Letter Case .............................................................. 165 5.2 Character Substitution ............................................... 166 5.3 Prefix/Suffix Code ..................................................... 178 5.4 Code ID ................................................................... 179 5.5 Length Code ............................................................ 186 5.6 Multi-Barcode Editor .................................................. 194 5.7 Removal of Special Character ..................................... 198 5.1 LETTER CASE By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case. Ignoring the original letter case, select [Upper Case] to output data in upper case only; otherwise, select [Lower Case] to output data in lower case only.   *Normal Upper Case Lower Case  Chapter 5 DEFINING OUTPUT FORMAT
166 Enter Setup 1664 Barcode Scanner User Guide  5.2 CHARACTER SUBSTITUTION Character substitution is performed on every occurrence of the first character specified. If only one character is specified, every occurrence of that character in the barcode will be taken away.  The first character will be replaced by the second character(s).   Up to three sets of character substitution can be configured.  If “Bluetooth® HID” or “USB HID” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type.  Key Type  Key Status Scan Code   Only 1 scan code value is allowed. Refer to 5.2.1 Select a Set for Character Substituion. N/A Normal Key   Up to 3 character strings are allowed.   Add Shift  Add Left Ctrl  Add Left Alt  Add Right Ctrl  Add Right Alt Refer to Keyboard Wedge Table. Note: The character substitution is performed only on the barcode itself and before the processing of editing formats. It is not applicable to the Prefix/Suffix Code, Code ID, Length Code, or any Additional Field.
    167 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 5.2.1 SELECT A SET FOR CHARACTER SUBSTITUION  Configure Set 1 Configure Set 2 Configure Set 31) Read the barcode above to enable character substitution by set.  For example, have the scanner read the “Set 1” barcode to configure the first set of character substitution. The scanner will respond with one short beep, high tone, to indicate more setup barcodes are required. 2) Read the “Hexadecimal Value” barcode on page 252 for the desired character substitution. For example,  KEY TYPE = NORMAL  Read “3”, “0”, “2”, and “D” to replace the character “0” with a dash “-”.  Read “3”, “0”, “2”, “D”, “3”, and “0” to replace the character “0” with a dash “-0”. KEY TYPE = SCAN CODE If you want to replace the character “0” with “a” (= “1C” on the scan code table): 1.  Read “3” and “0”. 2.  Read the “Scan Code” barcode. 3.  Read “1” and “C”. KEY TYPE = NORMAL + KEY STATUS = SHIFT If you want to replace the character “0” with “!” (= “Shift” + “1” on keyboard): 1.  Read “3” and “0”. 2.  Read the “Add Shift” barcode. 3.  Read “3” and “1”. 3) Read the “Validate” barcode to complete this setting. (The defined set or sets will be applied to all symbologies by default.)
168 Enter Setup 1664 Barcode Scanner User Guide  5.2.2 SYMBOLOGIES FOR CHARACTER SUBSTITUTION (ALL 3 SETS) By default character substitution will be performed on all symbologies. If the character substitution is not desired with one or more symbologies, read the “Do Not Apply” barcode for each undesired symbologies and all the three sets will be ignored for them. Character Substitution for Codabar  *Apply Do Not ApplyCharacter Substitution for Code 39  *Apply Do Not ApplyCharacter Substitution for Trioptic Code 39  *Apply Do Not ApplyCharacter Substitution for Code 93  *Apply Do Not Apply
    169 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Character Substitution for Code 128  *Apply Do Not ApplyCharacter Substitution for GS1-128  *Apply Do Not ApplyCharacter Substitution for ISBT 128  *Apply Do Not ApplyCharacter Substitution for EAN-8 (No Addon)  *Apply Do Not ApplyCharacter Substitution for EAN-8 Addon 2  *Apply Do Not Apply
170 Enter Setup 1664 Barcode Scanner User Guide  Character Substitution for EAN-8 Addon 5  *Apply Do Not ApplyCharacter Substitution for EAN-13 (No Addon)  *Apply Do Not ApplyCharacter Substitution for EAN-13 Addon 2  *Apply Do Not ApplyCharacter Substitution for EAN-13 Addon 5  *Apply Do Not ApplyCharacter Substitution for Italian Pharmacode  *Apply Do Not Apply
    171 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Character Substitution for Industrial 25  *Apply Do Not ApplyCharacter Substitution for Interleaved 25  *Apply Do Not ApplyCharacter Substitution for Matrix 25  *Apply Do Not ApplyCharacter Substitution for Chinese 25  *Apply Do Not ApplyCharacter Substitution for MSI  *Apply Do Not Apply
172 Enter Setup 1664 Barcode Scanner User Guide  Character Substitution for GS1 DataBar  *Apply Do Not ApplyCharacter Substitution for UPC-A (No Addon)  *Apply Do Not ApplyCharacter Substitution for UPC-A Addon 2  *Apply Do Not ApplyCharacter Substitution for UPC-A Addon 5  *Apply Do Not ApplyCharacter Substitution for UPC-E (No Addon)  *Apply Do Not Apply
    173 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Character Substitution for UPC-E Addon 2  *Apply Do Not ApplyCharacter Substitution for UPC-E Addon 5  *Apply Do Not ApplyCharacter Substitution for UCC Coupon Extended Code  *Apply Do Not ApplyCharacter Substitution for Code 11  *Apply Do Not ApplyCharacter Substitution for Composite CC-A/B  *Apply Do Not Apply
174 Enter Setup 1664 Barcode Scanner User Guide  Character Substitution for Composite CC-C  *Apply Do Not ApplyCharacter Substitution for Composite TLC-39  *Apply Do Not ApplyCharacter Substitution for US Postnet  *Apply Do Not ApplyCharacter Substitution for US Planet  *Apply Do Not ApplyCharacter Substitution for UK Postal  *Apply Do Not Apply
    175 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Character Substitution for Japan Postal  *Apply Do Not ApplyCharacter Substitution for Australian Postal  *Apply Do Not ApplyCharacter Substitution for Dutch Postal  *Apply Do Not ApplyCharacter Substitution for USPS 4CB/One Code/Intelligent Mail  *Apply Do Not ApplyCharacter Substitution for UPU FICS Postal  *Apply Do Not Apply
176 Enter Setup 1664 Barcode Scanner User Guide  Character Substitution for PDF417  *Apply Do Not ApplyCharacter Substitution for MicroPDF417  *Apply Do Not ApplyCharacter Substitution for Data Matrix  *Apply Do Not ApplyCharacter Substitution for Maxicode  *Apply Do Not ApplyCharacter Substitution for QR Code  *Apply Do Not Apply
    177 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Character Substitution for MicroQR  *Apply Do Not ApplyCharacter Substitution for Aztec  *Apply Do Not Apply
178 Enter Setup 1664 Barcode Scanner User Guide  5.3 PREFIX/SUFFIX CODE By default, there is no prefix code, and [ENTER] or [CR] (Carriage Return) is configured to be suffix code. Up to 8 characters can be configured, for example, “Barcode_”, and you will have the string appear in front of the barcode read, like this – “Barcode_1234567890”.  If “Bluetooth® HID” or “USB HID” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type.   Key Type  Key Status Scan Code   Up to 4 scan code values are allowed.  N/A Normal Key   Up to 8 character strings are allowed.   Add Shift  Add Left Ctrl  Add Left Alt  Add Right Ctrl  Add Right Alt Refer to Keyboard Wedge Table.    Configure Prefix Configure Suffix1) Read the barcode above to apply prefix code or suffix code separately, and follow steps 2~3. (Max. 8 characters each) 2) Read the “Hexadecimal Value” barcode on page 252 for the desired character string. For example, read “2” and “B” for the scanner to prefix or suffix the character [+]. 3) Read the “Validate” barcode to complete this setting.
    179 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 5.4 CODE ID Up to two characters for Code ID can be configured for each symbology. To make the Code ID configuration easier, the scanner provides five pre-defined Code ID sets that you can select one and make necessary changes on it.  If “Bluetooth® HID” or “USB HID” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type.   Key Type  Key Status Scan Code   Only 1 scan code value is allowed.  N/A Normal Key   Up to 2 character strings are allowed.   Add Shift  Add Left Ctrl  Add Left Alt  Add Right Ctrl  Add Right Alt Refer to Keyboard Wedge Table. Note: "]C1" is the Code ID of GS1-128 (EAN-128) barcodes; "]e0" is the default Code ID of GS1 DataBar (RSS) barcodes. 5.4.1 SELECT PRE-DEFINED CODE ID  Apply Code ID Set 1 Apply Code ID Set 2 Apply Code ID Set 3 Apply Code ID Set 4 Apply Code ID Set 5
180 Enter Setup 1664 Barcode Scanner User Guide  Code ID options  Set 1  Set 2  Set 3  Set 4  Set 5 Code 39  A  C  Y  M  A Trioptic Code 39  A  C  Y  M  X Italian Pharmacode  A  C  Y  M  A Industrial 25  C H H H S Interleaved 25  D  I  Z  I  S Matrix 25  E G G G S Chinese 25  Q  M  P  S  X Codabar F N X N F Code 93  I L L L G Code 128  H K K K C ISBT 128  H K K K C UPC-E S E C E E EAN-8  P B B FF E EAN-13  M A A F E UPC-A  J  A A A E MSI V V D P M UCC Coupon Code  G  F  I  C  C Code 11  K J J D H Composite CC-A/B  L  X  M  J  La Composite CC-C  N  Y  N  O  Lc Composite TLC-39  O Z O R L2 US Postnet  h  a  s  i  X US Planet  i  b  t  j  X UK Postal  j  c  u  k  X Japan Postal  k  d  v  l  X Australian Postal  l  e  w  m  X Dutch Postal  m  f  x  n  X USPS 4 CB / One Code / Intelligent Mail  n  g  y  o  X UPU FICS Postal  o  h  z  p  X PDF417 a O W T L MicroPDF417 b P V U L Data Matrix  c  Q  U  V  d Maxicode  d R T W U QR Code  e S S X Q
    181 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 MicroQR f T R Y Q Aztec g U Q Z z IATA z z r h S Macro PDF417  p i  a q L Macro MicroPDF417  q  j  b  r  L
182 Enter Setup 1664 Barcode Scanner User Guide  5.4.2 CHANGE CODE ID 1) Read the barcode below to change code ID of a specific symbology. 2) Read the “Hexadecimal Value” barcode on page 252 for the desired character string. For example, read “4” and “4” for applying the character [D] for Code ID. 3) Read the “Validate” barcode to complete this setting.   Configure Code ID for Codabar Configure Code ID for Code 39 Configure Code ID for Trioptic Code 39 Configure Code ID for Code 93 Configure Code ID for Code 128 Configure Code ID for ISBT 128 Configure Code ID for EAN-8 Configure Code ID for EAN-13 Configure Code ID for Italian Pharmacode Configure Code ID for Industrial 25
    183 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。  Configure Code ID for Interleaved 25 Configure Code ID for Matrix 25 Configure Code ID for Chinese 25 Configure Code ID for MSI Configure Code ID for UPC-A Configure Code ID for UPC-E Configure Code ID for UCC Coupon Code  Configure Code ID for Code 11  Configure Code ID for Composite CC-A/B  Configure Code ID for Composite CC-C  Configure Code ID for Composite TLC-39  Configure Code ID for US Postnet
184 Enter Setup 1664 Barcode Scanner User Guide   Configure Code ID for US Planet  Configure Code ID for UK Postal  Configure Code ID for Japan Postal  Configure Code ID for Australian Postal Configure Code ID for Dutch Postal  Configure Code ID for USPS 4CB / One Code / Intelligent Mail  Configure Code ID for UPU FICS Postal Configure Code ID for PDF417  Configure Code ID for MicroPDF417  Configure Code ID for Data Matrix  Configure Code ID for Maxicode  Configure Code ID for QR Code
    185 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。  Configure Code ID for MicroQR  Configure Code ID for Aztec  Configure Code ID for IATA  Configure Code ID for Macro PDF417  Configure Code ID for Macro MicroPDF417 5.4.3 CLEAR CODE ID SETTINGS  Clear All Code ID Settings
186 Enter Setup 1664 Barcode Scanner User Guide  5.5 LENGTH CODE A 4-digit code representing the length of barcode data (character count) can be inserted in front of data being transmitted. Such "Length" code can be individually enabled or disabled for each symbology.  Length Code for Codabar  Apply *Do Not ApplyLength Code for Code 39  Apply *Do Not ApplyLength Code for Trioptic Code 39  Apply *Do Not ApplyLength Code for Code 93  Apply *Do Not Apply
    187 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Length Code for Code 128  Apply *Do Not ApplyLength Code for GS1-128 & GS1 DataBar  Apply *Do Not ApplyLength Code for ISBT 128  Apply *Do Not ApplyLength Code for EAN-8  Apply *Do Not ApplyLength Code for EAN-13  Apply *Do Not Apply
188 Enter Setup 1664 Barcode Scanner User Guide  Length Code for Italian Pharmacode  Apply *Do Not ApplyLength Code for Industrial 25  Apply *Do Not ApplyLength Code for Interleaved 25  Apply *Do Not ApplyLength Code for Matrix 25  Apply *Do Not ApplyLength Code for Chinese 25  Apply *Do Not Apply
    189 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Length Code for MSI  Apply *Do Not ApplyLength Code for UPC-A  Apply *Do Not ApplyLength Code for UPC-E  Apply *Do Not ApplyLength Code for UCC Coupon Extended Code  Apply *Do Not ApplyLength Code for Code 11  Apply *Do Not Apply
190 Enter Setup 1664 Barcode Scanner User Guide  Length Code for Composite CC-A/B  Apply *Do Not ApplyLength Code for Composite CC-C  Apply *Do Not ApplyLength Code for Composite TLC-39  Apply *Do Not ApplyLength Code for US Postnet  Apply *Do Not ApplyLength Code for US Planet  Apply *Do Not Apply
    191 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Length Code for UK Postal  Apply *Do Not ApplyLength Code for Japan Postal  Apply *Do Not ApplyLength Code for Australian Postal  Apply *Do Not ApplyLength Code for Dutch Postal  Apply *Do Not ApplyLength Code for USPS 4CB/One Code/Intelligent Mail  Apply *Do Not Apply
192 Enter Setup 1664 Barcode Scanner User Guide  Length Code for UPU FICS Postal  Apply *Do Not ApplyLength Code for PDF417  Apply *Do Not ApplyLength Code for MicroPDF417  Apply *Do Not ApplyLength Code for Data Matrix  Apply *Do Not ApplyLength Code for Maxicode  Apply *Do Not Apply
    193 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Length Code for QR Code  Apply *Do Not ApplyLength Code for MicroQR  Apply *Do Not ApplyLength Code for Aztec  Apply *Do Not Apply
194 Enter Setup 1664 Barcode Scanner User Guide  5.6 MULTI-BARCODE EDITOR The Multi-Barcode Editor allows deciding the output sequence of a concatenation of barcodes. Up to five barcodes can be specified. When enable this mode, it will force the scanner to apply Laser mode as the scan mode.  Note:  The Multi-Barcode Editor has nothing to do with Multi-Barcode Mode. The barcodes that are found meeting the specified criteria below will be arranged in the desired sequence.   Code Type  4-digit barcode length, excluding prefix, suffix, length code, etc.  Matching the first character of barcode data
    195 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 5.6.1 EDIT A CONCATENATION OF BARCODES  Edit Output Sequence1) Read the barcode above to start editing a concatenation of barcodes. 2) Code Type setting – read the “Hexadecimal Value” barcode on page 252 for Code Type of the (first) barcode. For example, read “4” and “1” for Code 39.  Code Type  Symbology  Code Type  Symbology 40 (@)  ISBT 128     41 (A)  Code 39     42 (B)  Italian Pharmacode     43 (C)  N/A     44 (D)  Industrial 25  64 (d)  TLC-39 (TCIF Linked Code 39) 45 (E)  Interleaved 25  65 (e)  Trioptic Code 39 46 (F)  Matrix 25     47 (G)  Codabar (NW7)  67 (g)  Code 11 48 (H)  Code 93     49 (I)  Code 128     4A (J)  UPC-E0 / UPC-E1  6A (j)  Composite CC-C 4B (K)  UPC-E with Addon 2  6B (k)  PDF417 4C (L)  UPC-E with Addon 5  6C (l)  MicroPDF417 4D (M)  EAN-8  6D (m)  Data Matrix 4E (N)  EAN-8 with Addon 2  6E (n)  Maxicode 4F (O)  EAN-8 with Addon 5  6F (o)  QR Code 50 (P)  EAN-13  70 (p)  US Postnet 51 (Q)  EAN-13 with Addon 2  71 (q)  US Planet 52 (R)  EAN-13 with Addon 5  72 (r)  UK Postal 53 (S)  MSI  73 (s)  Japan Postal 54 (T)  N/A  74 (t)  Australian Postal 55 (U)  GS1-128 (EAN-128)  75 (u)  Dutch Postal 56 (V)  UPC-A  76 (v)  Composite CC-A/B 57 (W)  UPC-A with Addon 2  77 (w)  Macro PDF417 58 (X)  UPC-A with Addon 5  78 (x)  Macro MicroPDF417
196 Enter Setup 1664 Barcode Scanner User Guide      79 (y)  Chinese 25 5A (Z)  N/A  7A (z)  Aztec 5B ( [ )  GS1 DataBar (RSS)  7B ({)  Micro QR     7C (|)  USPS 4CB / One Code / Intelligent Mail     7D (})  UPU FICS Postal     7E (~)  UCC Coupon Extended Code  3) Barcode Length setting – read the “Decimal Value” barcode on page 251 for the 4-digit length of the (first) barcode. For example, read “0065” for barcode length of 65 characters or read “0000” for any length.  Note: If not reading 0000 for any length, the 4-digit length must exclude prefix, suffix (0x0d by default), length code, etc. 4) Matching Character setting – read the “Hexadecimal Value” barcode on page 252 for the 1st character that must be found matching in the (first) barcode. For example, read “4” and “1” for matching character “A” as the first character in the barcode or read “00” for any character. 5) Read twice the “F” barcode on page 252 (“FF”) to complete the setting of each barcode. 6) Read the “Validate” barcode to end the editing of the barcode set.
    197 Update  Chapter 5  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 5.6.2 ACTIVATE THE CONCATENATION OF BARCODES By default, the output sequence editing of the concatenation of barcodes is not applied.  When “Enforce Output Sequence” is enabled, all barcodes read by the scanner must meet with the criteria for the concatenation. If data is found excluded from all output sequence sets (= not meeting with the criteria), the scanner will not accept the reading, and therefore, data will not be transmitted. When “Apply Output Sequence” is enabled, only barcodes found meeting with the criteria are counted for the concatenation. Those found not meeting with the criteria are processed normally and individually. Note: When it requires reading more barcodes to complete the “output sequence” requirements, the scanner will respond with one short beep (low tone). After reading an acceptable barcode, its LED indicator will become solid green and go off quickly (= Good Read).         Upon completion of reading acceptable barcodes, the scanner will respond with one short beep (high tone) and its LED indicator will become solid green and go off quickly (= Good Read).    *Ignore Output Sequence Enforce Output Sequence Apply Output SequenceWarning:  When you disable the Multi-Barcode Editor later, the scan mode remains unchanged. If Laser mode is not desired, proceed to select a scan mode best suits your application.
198 Enter Setup 1664 Barcode Scanner User Guide  5.7 REMOVAL OF SPECIAL CHARACTER You can only specify 1 character, but it will remove every matching character encountered from the starting position of barcode data until a different character is met. For example, if it is configured to remove the character “0” (hex value is “30”), one or more zeros will be stripped off the barcode data “012345” and “00012345”. However, for barcode data “010333”, only the first zero will be stripped off.   Remove Special Character1) Read the barcode above to remove the specified character.  2) Read the “Hexadecimal Value” barcode on page 252 for the desired character string.  For example, read “3” and “0” for the scanner to remove the character “0”. 3) Read the “Validate” barcode to complete this setting.
    199 Update  The scanner allows advanced data editing by applying user-configured editing formats. The whole processed data can be divided into fields by user-specified rules. These fields together with the user-configurable additional fields consist of the data actually sent to the host computer. For 1664 to apply any editing format, the maximum output data length of a barcode is 7 KB after configuration. When the data length exceeds 7 KB, editing format will not take effect.  [Prefix Code] [Code ID]  [Length Code] [Data] [Suffix Code] Additional Field(s) None        by default  None        by default None        by default  Barcode itself  0x0d        by default    IN THIS CHAPTER 6.1 Activating Editing Formats.......................................... 200 6.2 How to Configure Editing Formats ............................... 202 6.3 Configuring Format — Define Data Criteria ................... 205 6.4 Configuring Format — Define Data Field ....................... 217 6.5 Configuring Format — Define Transmission Sequence .... 226 6.6 Programming Examples ............................................. 228                          Chapter 6 APPLYING FORMATS FOR DATA EDITING
200  End Programming Format 1664 Barcode Scanner User Guide  6.1 ACTIVATING EDITING FORMATS 6.1.1 ACTIVATE EDITING FORMATS If you have already configured any editing format before, you may directly apply the editing format. If not, you must start with configuring an editing format first, and then, activate the editing format when it is desired in use.  Editing Format 1  Enable *DisableEditing Format 2  Enable *DisableEditing Format 3  Enable *DisableEditing Format 4  Enable *Disable
    201 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Editing Format 5  Enable *Disable6.1.2 EXCLUSIVE DATA EDITING By default, only barcodes found meeting with the criteria are processed by the editing formats. Those found not meeting with the criteria are processed normally. When “Exclusive Data Editing” is enabled, all barcodes read by the scanner must be processed by the editing formats. If data is found excluded from all enabled editing formats (= not meeting with the specified criteria), the scanner will not accept the reading, and therefore, data will not be transmitted.   Yes *No
202  End Programming Format 1664 Barcode Scanner User Guide  6.2 HOW TO CONFIGURE EDITING FORMATS
    203 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 6.2.1 SELECT FORMAT TO CONFIGURE Start Programming Format Select one editing format (Format 1~5) and the parameters pertaining to the editing format can then be configured – applicable code type, data length, matching string & location, start position, field adjustment, total number of fields, field settings (field-dividing rule), additional fields, and field transmission sequence.  Up to five different formats can be specified.  Configure Format 1 Configure Format 2 Configure Format 3 Configure Format 4 Configure Format 5Note: Before completing the programming of an editing format, if have the scanner read any barcode for parameters other than those pertaining to the editing format, it will automatically abort the programming process.   End Programming Format After having configured all the desired parameters, you must have the scanner read the “End Programming Format” barcode, which can be located at the bottom of every even page in this chapter.  End Programming Format
204  End Programming Format 1664 Barcode Scanner User Guide  6.2.2 RESTORE DEFAULT FORMAT You may select an existing editing format and have the defaults restored. The default settings of an editing format are listed below.  Editing format  Defaults Applicable Code Type  All Data Length  0 (No qualification) Matching String  Disable Matching String Location  None Start Position  From head Field Adjustment  No adjustment Total Number of Fields  1 Field Setting – field-dividing rule  Not configured Additional Fields  None Field Transmission Sequence  F1   Restore Default Format
    205 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 6.3 CONFIGURING FORMAT — DEFINE DATA CRITERIA Three applicable conditions can be configured to check whether the data read by the scanner can be processed by the particular editing format.  Note:  Data editing cannot be performed unless the three conditions are all met. 6.3.1 APPLICABLE CODE TYPE By default, barcodes of all the supported symbologies will be processed by any editing format, if having been configured and enabled. For quick configuration, you may first clear all, and then select the desired symbologies. Note:  You must have at least one symbology selected.   *Apply to All Clear All
206  End Programming Format 1664 Barcode Scanner User Guide  Editing Format for Codabar  *Apply Do Not ApplyEditing Format for Code 39  *Apply Do Not ApplyEditing Format for Trioptic Code 39  *Apply Do Not ApplyEditing Format for Code 93  *Apply Do Not ApplyEditing Format for Code 128  *Apply Do Not Apply
    207 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Editing Format for GS1-128 & GS1 DataBar  *Apply Do Not ApplyEditing Format for ISBT 128  *Apply Do Not ApplyEditing Format for EAN-8  *Apply Do Not ApplyEditing Format for EAN-8 Addon 2  *Apply Do Not ApplyEditing Format for EAN-8 Addon 5  *Apply Do Not Apply
208  End Programming Format 1664 Barcode Scanner User Guide  Editing Format for EAN-13  *Apply Do Not ApplyEditing Format for EAN-13 Addon 2  *Apply Do Not ApplyEditing Format for EAN-13 Addon 5  *Apply Do Not ApplyEditing Format for Italian Pharmacode  *Apply Do Not ApplyEditing Format for Industrial 25  *Apply Do Not Apply
    209 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Editing Format for Interleaved 25  *Apply Do Not ApplyEditing Format for Matrix 25  *Apply Do Not ApplyEditing Format for Chinese 25  *Apply Do Not ApplyEditing Format for MSI  *Apply Do Not ApplyEditing Format for UPC-A  *Apply Do Not Apply
210  End Programming Format 1664 Barcode Scanner User Guide  Editing Format for UPC-A Addon 2  *Apply Do Not ApplyEditing Format for UPC-A Addon 5  *Apply Do Not ApplyEditing Format for UPC-E  *Apply Do Not ApplyEditing Format for UPC-E Addon 2  *Apply Do Not ApplyEditing Format for UPC-E Addon 5  *Apply Do Not Apply
    211 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Editing Format for UCC Coupon Extended Code  *Apply Do Not ApplyEditing Format for Code 11  *Apply Do Not ApplyEditing Format for Composite CC-A/B  *Apply Do Not ApplyEditing Format for Composite CC-C  *Apply Do Not ApplyEditing Format for Composite TLC-39  *Apply Do Not Apply
212  End Programming Format 1664 Barcode Scanner User Guide  Editing Format for US Postnet  *Apply Do Not ApplyEditing Format for US Planet  *Apply Do Not ApplyEditing Format for UK Postal  *Apply Do Not ApplyEditing Format for Japan Postal  *Apply Do Not ApplyEditing Format for Australian Postal  *Apply Do Not Apply
    213 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Editing Format for Dutch Postal  *Apply Do Not ApplyEditing Format for USPS 4CB/One Code/Intelligent Mail  *Apply Do Not ApplyEditing Format for UPU FICS Postal  *Apply Do Not ApplyEditing Format for PDF417  *Apply Do Not ApplyEditing Format for MicroPDF417  *Apply Do Not Apply
214  End Programming Format 1664 Barcode Scanner User Guide  Editing Format for Data Matrix  *Apply Do Not ApplyEditing Format for Maxicode  *Apply Do Not ApplyEditing Format for QR Code  *Apply Do Not ApplyEditing Format for MicroQR  *Apply Do Not ApplyEditing Format for Aztec  *Apply Do Not Apply
    215 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 6.3.2 DATA LENGTH The length must include prefix, suffix (0x0d by default), length code, etc. By default, barcodes of any length (character count) are eligible for data editing.   It can be specified a value from 0 to 254.  When zero is given to both, the scanner will not perform the length qualification.  1) Read the barcode below to specify Max. Length or Min. Length separately, and follow steps 2~3.   Max. Length Min. Length 2) Read the “Decimal Value” barcode on page 251 for the desired length.  3) Read the “Validate” barcode on the same page to complete this setting.
216  End Programming Format 1664 Barcode Scanner User Guide  6.3.3 MATCHING STRING & LOCATION By default, no matching string is specified, and therefore, it is disabled. You may enable this feature by specifying a matching string; up to four characters are allowed.  When the Matching String Location is zero, the scanner will only check for the existence of the matching string in the barcode data.  Specify a value from 1 to 254 to indicate where the matching string starts in the barcode data.  1) Read the barcode to specify a matching string.   Matching String… 2) Read the “Hexadecimal Value” barcode on page 252 for the desired character string.  3) Read the “Validate” barcode to complete this setting. 4) Read the barcode to specify the location of the matching string.   Location of Matching String… 5) Read the “Decimal Value” barcode on page 251 for the desired location.  6) Read the “Validate” barcode on the same page to complete this setting.
    217 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 6.4 CONFIGURING FORMAT — DEFINE DATA FIELD 6.4.1 START POSITION Data can be divided into fields in one of the following direction –   from head (F1) to tail (F5)  from tail (F1) to head (F5)   *From Head From Tail6.4.2 FIELD ADJUSTMENT You may apply equal length to all fields, if necessary. If data is found longer than specified, it will be truncated automatically. When data is found shorter, it will add “Space” (0x20) to field.   *No adjustment Set length to adjust fields… (*0)1) Read the barcode above to adjust field by length.  2) Read the “Decimal Value” barcode on page 251 for the desired field length. 3) Read the “Validate” barcode on the same page to complete this setting.
218  End Programming Format 1664 Barcode Scanner User Guide  6.4.3 TOTAL NUMBER OF FIELDS Data can be divided into at most 6 fields; each of them is numbered from F1 to F6 accordingly. However, only F1~F5 can be configured.   The total number of fields must be specified correctly. If three fields are configured for the editing format, the data characters after F3 will be assigned to F4 automatically. This feature is quite useful especially when data of variable lengths is processed by editing formats.   *One Field Two Fields Three Fields Four Fields Five Fields Six FieldsNote: The number of configurable fields is always one less than the total number of fields specified. The extra data characters beyond the last field configured will be automatically assigned to the next field.
    219 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 6.4.4 FIELD SETTINGS Data eligible for editing formats is divided into fields by user-specified rules – either using the field terminating string or specified field length. By Terminating String Specify the field terminating string. Up to two characters are allowed. The scanner will search for the occurrence of this particular string in the data.   By default, this string will be included in the field. You may discard it. By Length Alternatively, you may simply specify the field length. The scanner will assign the next specified number of characters into the field.  Field 1 Setting 1.  Read the barcode below to divide field 1 by a specified terminating string.  Select  Field Separator  to Divide Field 1…2.  Read the “Hexadecimal Value” barcode on page 252 for the desired character string. 3.  Read the “Validate” barcode to complete this setting. 4.  Read the “Discard Separator” barcode if the field separator is not desired in the field.  *Include Separator Discard Separator If not dividing the field by a specific separator, you may divide it by a specified length. 1.  Read the barcode below to divide field 1 by length.  Divide Field 1  by Length2.  Read the “Decimal Value” barcode on page 251 for the desired field length. 3.  Read the “Validate” barcode on the same page to complete this setting.
220  End Programming Format 1664 Barcode Scanner User Guide  Field 2 Setting 1.  Read the barcode below to divide field 2 by a specified terminating string.  Select  Field Separator  to Divide Field 2…2.  Read the “Hexadecimal Value” barcode on page 252 for the desired character string. 3.  Read the “Validate” barcode to complete this setting. 4.  Read the “Discard Separator” barcode if the field separator is not desired in the field.  *Include Separator Discard Separator If not dividing the field by a specific separator, you may divide it by a specified length. 1.  Read the barcode below to divide field 2 by length.  Divide Field 2  by Length2.  Read the “Decimal Value” barcode on page 251 for the desired field length. 3.  Read the “Validate” barcode on the same page to complete this setting.
    221 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Field 3 Setting 1.  Read the barcode below to divide field 3 by a specified terminating string.  Select  Field Separator  to Divide Field 3…2.  Read the “Hexadecimal Value” barcode on page 252 for the desired character string. 3.  Read the “Validate” barcode to complete this setting. 4.  Read the “Discard Separator” barcode if the field separator is not desired in the field.  *Include Separator Discard Separator If not dividing the field by a specific separator, you may divide it by a specified length. 1.  Read the barcode below to divide field 3 by length.  Divide Field 3  by Length2.  Read the “Decimal Value” barcode on page 251 for the desired field length. 3.  Read the “Validate” barcode on the same page to complete this setting.
222  End Programming Format 1664 Barcode Scanner User Guide  Field 4 Setting 1.  Read the barcode below to divide field 4 by a specified terminating string.  Select  Field Separator  to Divide Field 4…2.  Read the “Hexadecimal Value” barcode on page 252 for the desired character string. 3.  Read the “Validate” barcode to complete this setting. 4.  Read the “Discard Separator” barcode if the field separator is not desired in the field.  *Include Separator Discard Separator If not dividing the field by a specific separator, you may divide it by a specified length. 1.  Read the barcode below to divide field 4 by length.  Divide Field 4  by Length2.  Read the “Decimal Value” barcode on page 251 for the desired field length. 3.  Read the “Validate” barcode on the same page to complete this setting.
    223 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Field 5 Setting 1.  Read the barcode below to divide field 5 by a specified terminating string.  Select  Field Separator  to Divide Field 5…2.  Read the “Hexadecimal Value” barcode on page 252 for the desired character string. 3.  Read the “Validate” barcode to complete this setting. 4.  Read the “Discard Separator” barcode if the field separator is not desired in the field.  *Include Separator Discard Separator If not dividing the field by a specific separator, you may divide it by a specified length. 1.  Read the barcode below to divide field 5 by length.  Divide Field 5  by Length2.  Read the “Decimal Value” barcode on page 251 for the desired field length. 3.  Read the “Validate” barcode on the same page to complete this setting.
224  End Programming Format 1664 Barcode Scanner User Guide  Additional Fields Up to five additional fields can be created for each editing format; each of them is numbered from AF1 to AF5 accordingly.  If “Bluetooth® HID” or “USB HID” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type.  Key Type  Key Status Scan Code   Up to 2 scan code values are allowed. N/A Normal Key   Up to 4 character strings are allowed.   Add Shift  Add Left Ctrl  Add Left Alt  Add Right Ctrl  Add Right Alt Refer to Keyboard Wedge Table.   1.  Read the barcode below to specify an additional field, one at a time.  Additional Field 1… Additional Field 2… Additional Field 3… Additional Field 4… Additional Field 5…2.  Read the “Hexadecimal Value” barcode on page 252 for the desired additional field. 3.  Read the “Validate” barcode to complete this setting.
    225 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 6.4.5 PAUSE FIELD SETTING Pause Field Time You can limit the pause time interval (1~16). By default, it is set to 1 second.  Pause Field Time  1~16 sec.  (*1)1.  Read the barcode above to specify the time interval for the Pause Field. (It is set to 1 by default.) 2.  Read the “Decimal Value” barcode on page 251. For example, read “1” and “0” for setting the Pause Field Time to 10 seconds. 3.  Read the “Validate” barcode on the same page to complete this setting.
226  End Programming Format 1664 Barcode Scanner User Guide  6.5 CONFIGURING FORMAT — DEFINE TRANSMISSION SEQUENCE After configuring the data fields and additional fields, you must now program the transmission sequence of these fields that comprise the final data. This field transmission sequence can be assigned in any desired order and fields can be assigned multiple times as well.  Note:  Up to twelve fields can be assigned. 1) Read the “Start” barcode to begin with programming the field transmission sequence.  Start Programming… 2) Program the transmission sequence by reading the desired fields as well as additional fields.  Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Additional Field 1
    227 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。  Additional Field 2 Additional Field 3 Additional Field 4 Additional Field 5 Pause Field Null Character Field   3) Read the “End” barcode to complete this setting.  End Programming…
228  End Programming Format 1664 Barcode Scanner User Guide  6.6 PROGRAMMING EXAMPLES 6.6.1 EXAMPLE I Extract data from the 10th character to the 19th character... The editing format should be configured as follows: 1.  Read the “Enter Setup” barcode to enter the Configuration Mode. 2.  Read the “Configure Format 1” barcode. 3.  Read the “Clear All” and “Code 128” barcodes for applicable code type. 4.  Read the “Three Fields” barcode. 5.  Read the “Divide Field 1 by Length” barcode, and set length to 9. Field 1 data starts from the 1st character to the 9th character. 6.  Read the “Divide Field 2 by Length” barcode, and set length to 10. Field 2 data starts from the 10th character to the 19th character. 7.  Read the “Start (Programming)” barcode to program the transmission sequence. 8.  Read the “Field 2” barcode. 9.  Read the “End” barcode to complete the transmission sequence setting. 10.  Read the “End Programming Format” barcode to complete the setting of Editing Format 1. 11.  Read the “Enable Format 1” barcode to apply Editing Format 1 to Code 128. 12.  Read the “Update” barcode to exit the Configuration Mode.
    229 Update  Chapter 6  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 6.6.2 EXAMPLE II Extract the date code, item number, and quantity information from barcodes. Data in a barcode is encoded like this:   From the 1st character to the 6th character is the date code.   From the 7th character to the dash ‘-’ character is the item number.  After the dash ‘-’ character is the quantity information. Data will be transmitted like this:  The item number goes first, then a TAB character, followed by the date code, then another TAB character, and finally the quantity information.  The editing format should be configured as follows: 1.  Read the “Enter Setup” barcode to enter the Configuration Mode. 2.  Read the “Configure Format 2” barcode. 3.  Read the “Three Fields” barcode. 4.  Read the “Divide Field 1 by Length” barcode, and set length to 6. Field 1 data starts from the 1st character to the 6th character. 5.  Read the “Select Field Separator to Divide Field 2” barcode, and use a dash ‘-’ character. Field 2 data starts from the 7th character until the dash ‘-’ character is met. 6.  Read the “Additional Field 1” barcode, and use a tab character for the field. 7.  Read the “Start (Programming)” barcode to program the transmission sequence. 8.  Read the “Field 2”, “Additional Field 1”, “Field 1”, “Additional Field 1”, “Field 3” barcodes. 9.  Read the “End” barcode to complete the transmission sequence (F2 A1 F1 A1 F3) setting. 10.  Read the “End Programming Format” barcode to complete the setting of Editing Format 1. 11.  Read the “Enable Format 2” barcode to apply Editing Format 2 to all code types. 12.  Read the “Update” barcode to exit the Configuration Mode.
230  End Programming Format 1664 Barcode Scanner User Guide
    231 Update     Optical Characteristics  1664 Scan Engine  2D Imager Light Source  Visible red LED RF Characteristics WPAN Module  Bluetooth® Class 2 compliance Coverage (line-of-sight)  20 meters with 3610 Interface Supported   Serial Port Profile (Bluetooth® SPP)  Human Interface Device Profile (Bluetooth® HID)  3610  Direct USB HID   Direct USB Virtual COM  Physical Characteristics Memory   10 KB for transmit buffer  4MB flash for memory mode Switch  Push-button switch for [Trigger] key, plus [Power/Delete] key Indication  Triple-color LED (Red/Green/Blue) and beeper Dimensions  110 x 45 x 25 mm Weight <130g  SPECIFICATIONS
232 Enter Setup 1664 Barcode Scanner User Guide  Electrical Characteristics Battery  Rechargeable Li-ion battery — 3.7 V, 850 mAh Power Adaptor Input  AC 100~240 V (50/60 Hz) Output  DC 5V 2A (Battery Charger) Operating Temperature  0 °C to 40 °C Environmental Characteristics Temperature Operating Storage 0 °C to 50 °C -20 °C to 60 °C Humidity (Non-condensing)  Operating Storage 10% to 90% 5% to 95% Resistance Electrostatic Discharge   ± 15 kV air discharge, ± 8 kV contact discharge Programming Support Configuration via Setup Barcodes  Use setup barcodes or host serial commands. Software Windows®-based ScanMaster Firmware upgradeable  Download firmware updates via the download utility. Accessories (√  means “supported”) CipherLab Dongle(3610)  √ Rechargeable Li-ion Battery  √ Direct USB Cable  √ Wristband  √ Protective Cover (Pouch)  √ Single Battery Charger  √
    233 Update  Upgrade firmware of one scanner at a time. For example, turn off each of the rest scanners when there is more than one scanner connected to host computer. Note: 1. In case it fails downloading due to low battery, make sure the targe scanner is        loaded with good battery and the battery charge is enough.               2. In order to avoid the data losing during firmware upgrade. Please save or upload all the data from the flash memory before beginning firmware upgrade. HOW TO UPGRADE FIRMWARE USING 3610 1) Connect 3610 to the USB port of PC after installing its driver. 2) Refer to 3.1.1 Connect to 3610 the target scanner to connect to 3610. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3610.  3) Read the following barcodes in sequence to configure the scanner to use USB Virtual COM as download interface.    Enter Setup  Activate 3610 USB  Virtual COM  Update Note:  For 1664, also choose to use “Direct” USB Virtual COM interface. 4) Read the following barcodes in sequence for the scanner to enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading.  Appendix I FIRMWARE UPGRADE
234 Enter Setup 1664 Barcode Scanner User Guide    Enter Setup Download 5) Run the download utility “ProgLoad.exe” on your computer.   Kernel Program  User Program K1664_V*.shx STD1664_V*.shx         For the communication settings, select “RS-232” and the correct COM port for USB Virtual COM interface.  Ignore the baud rate setting.  For the file option, click [Browse] to select the target file for firmware update.   Click [OK].    6) After upgrading kernel, you will need to manually restart the scanner.      After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully.  Note: The output interface remains unchanged as specified in step 3 (= USB Virtual COM).
    235 Update Appendix I  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。USING DIRECT USB VIRTUAL COM   1) Use the provided USB cable to connect 1661/1664 to the USB port of PC. It may need to install its driver first! 2) Read the following barcodes in sequence to configure 1664 to use Direct USB Virtual COM as download interface and enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading.    Enter Setup Activate Direct USB Virtual COM for download 3) Run the download utility “ProgLoad.exe” on host computer.   Kernel Program  User Program K1664_V*.shx STD1664_V*.shx         For the communication settings, select “RS-232” and the correct COM port for Direct USB Virtual COM interface.  Ignore the baud rate setting.  For the file option, click [Browse] to select the target file for firmware update.   Click [OK].    4) After upgrading kernel, it needs to restart the scanner manually.      After upgrading the user program, the scanner will restart itself automatically once the download is completely.
236 Enter Setup 1664 Barcode Scanner User Guide  Note: Because 1664 supports to download firmware via Direct USB Virtual COM interface, the output interface will be set to the previous used one upon completion of firmware upgrade.   USING BLUETOOTH® DONGLE 1) Refer to 3.2.3 Connect to Dongle for the target scanner to accept the connection request from your computer. 2) Read the following barcodes in sequence to configure the scanner to use Bluetooth® SPP as download interface.    Enter Setup Activate Bluetooth® SPP Update 3) Read the following barcodes in sequence for the scanner to enter the download mode.  The scanner will respond with beeps to indicate it is ready for downloading.    Enter Setup Download 4) Run the download utility “ProgLoad.exe” on your computer.   Kernel Program  User Program K1664_V*.shx STD1664_V*.shx
    237 Update Appendix I  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。       For the communication settings, select “RS-232” and the correct COM port for Bluetooth® SPP interface.  Ignore the baud rate setting.  For the file option, click [Browse] to select the target file for firmware update.   Click [OK].       5) After upgrading kernel, you will need to manually restart the scanner.      After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully.  Note:  The output interface remains unchanged as specified in step 2 (=Bluetooth® SPP).
238 Enter Setup 1664 Barcode Scanner User Guide  HOW TO UPGRADE 3610 FIRMWARE Connect 3610 to the USB port of PC after installing its driver. Refer to 3.1.1 Connect to 3610 for the target scanner to connect to 3610. UPGRADING 3610 CPU FIRMWARE     1) Read the following barcodes in sequence for 3610 to enter the download mode. The Communication LED on 3610 will be flashing red to indicate it is ready for downloading.   Enter Setup Download 3610  CPU Firmware   2) Run the download utility “ProgLoad.exe” on your computer.  Kernel Program  User Program K3610_V*.shx STD3610_V*.shx         For the communication settings, select “RS-232” and the correct COM port for USB Virtual COM interface.  Ignore the baud rate setting.  For the file option, click [Browse] to select the target file for firmware update.   Click [OK].    3) The 3610 will automatically restart itself when upgrading firmware is completed successfully.
    239 Update Appendix I  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。4) Read the “Update” barcode for the scanner to resume its operation (exit the configuration mode).   Update  UPGRADING 3610 USB BRIDGE FIRMWARE 1) Read the following barcodes in sequence for 3610 to enter the download mode. The Communication LED on 3610 will be flashing red to indicate it is ready for downloading.     Enter Setup Download 3610  USB Bridge Firmware   2) Run the download utility “ProgLoad.exe” on your computer.   Kernel Program  User Program K3610Bridge_V*.shx STD3610Bridge_V*.shx         For the communication settings, select “RS-232” and the correct COM port for USB Virtual COM interface.  Ignore the baud rate setting.  For the file option, click [Browse] to select the target file for firmware update.   Click [OK].
240 Enter Setup 1664 Barcode Scanner User Guide  3) The 3610 will automatically restart itself when upgrading firmware is completed successfully. 4) Read the “Update” barcode for the scanner to resume its operation (exit the configuration mode).   Update
    241 Update  SERIAL COMMANDS D Purpose  To disable the scanner. Remarks  “D” E Purpose  To enable the scanner. Remarks  “E” #@ nnnnnn <CR> Purpose  To configure the scanner. Remarks  nnnnnn – the six digits of command parameters.  For example, “109952” is to list the current Code ID settings.  “0x23” + “0x40” + “0x31” + “0x30” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d”Note: After configuring the scanner, you may send the serial command “#@109999” to save the settings. #@ - - - -<CR> Purpose  To halt the scanner. Remarks  “0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d” #@ . . . . <CR> Purpose  To resume operation. Remarks  “0x23” + “0x40” + “0x2e” + “0x2e” + “0x2e” + “0x2e” + “0x0d” #@////<CR> Purpose  To respond with a beep. Remarks  “0x23” + “0x40” + “0x2f” + “0x2f” + “0x2f” + “0x2f” + “0x0d”   Appendix II HOST SERIAL COMMANDS Serial Command List Page 3
242 Enter Setup 1664 Barcode Scanner User Guide  #@TRIGOFF<CR> Purpose  To disable the software trigger Remarks  “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x46” + “0x46” + “0x0d” #@TRIGON<CR> Purpose  To enable the software trigger Remarks  “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x4e” + “0x0d”#@RDSN<CR> Purpose  Read serial number Remarks  “0x23” + “0x40” + “0x52” + “0x44” + “0x53” + “0x4E” + “0x0D” EXAMPLE You may run HyperTerminal.exe on the host computer to send serial commands to the scanner via USB Virtual COM or Bluetooth® SPP.  For the scanner to stop immediately –  D  For the scanner to resume working –  E  For the scanner to change the beeper to medium volume and beep –  #@101011<CR> #@////<CR>  For the scanner to change the beeper to minimal volume and beep –  #@101010<CR> #@////<CR>  For the scanner to change the beeper frequency to 8 kHz (for Good Read Beep only) and beep –  #@101001<CR> #@////<CR>  For the scanner to change the beeper length to longest (for Good Read Beep only) and beep –  #@101008<CR> #@////<CR>   For the scanner to save the settings, send the serial command “#@109999” –  #@101011<CR> #@109999<CR>
    243 Update  Appendix II  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。  For the scanner to read the serial number and beep -  #@RDSN<CR> #@////<CR> Note: (1) For USB Virtual COM, only configure the first scanner that connects to 3610. To identify the scanner, send the serial command to have it respond with a beep. (2) For Bluetooth® SPP, allows configuring up to seven scanners at the same time.   3610 SETUP BARCODES & SERIAL COMMANDS Normally, configure the 3610 dongle by having a connected scanner read 3610-related setup barcodes. 1) Connect 3610 to the USB port of PC. 3610 needs to install its driver first! 2) Refer to 3.1.1 Connect to 3610 for the target scanner to connect to 3610. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3610.  3) Read the following barcodes in sequence to configure 3610.    Enter Setup  Update For 3610-related setup barcodes, refer to the Serial Command table below. Note that for the “Version” and “GetID” barcodes, it must run HyperTerminal.exe or any text editor to receive the information.  If the output interface is USB Virtual COM, run HyperTerminal.exe on the host computer to receive the information.   If the output interface is USB HID, run any text editor to receive the information.      (3610-related setup barcodes)
244 Enter Setup 1664 Barcode Scanner User Guide  3610 SERIAL COMMAND TABLE Config<CR> Purpose  To configure 3610. Here is the setup barcode for this serial command: ConfigRemarks  A list of the current settings will be displayed. Run HyperTerminal.exe on your computer and change the settings one by one. DefaultSetting<CR> Purpose  To restore the default settings. Here is the setup barcode for this serial command: DefaultSettingSingleConnection<CR> Purpose  To allow only one scanner connecting to 3610. Here is the setup barcode for this serial command: SingleConnectionMultiConnection<CR> Purpose  To allow up to seven scanners connecting to 3610. Here is the setup barcode for this serial command: MultiConnectionUseOnePortforAll<CR> Purpose  To use one Virtual COM port for all whenever connecting 3610 to PC via USB. This setting requires to connect one 3610 at a time, and will facilitate configuring a great amount of 3610 via the same Virtual COM port (for administrators’ or factory use). Here is the setup barcode for this serial command: UseOnePortforAll
    245 Update  Appendix II  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 UseVariablePort<CR> Purpose  To use variable Virtual COM port when connecting more than one 3610 to PC via USB. Here is the setup barcode for this serial command: UseVariablePortVersion<CR> Purpose  To get the firmware versions (CPU+USB Bridge). Here is the setup barcode for this serial command: VersionGetID<CR> Purpose  To get MAC ID. Here is the setup barcode for this serial command: GetIDDownload<CR> Purpose  To download CPU firmware to 3610. Here is the setup barcode for this serial command: DownloadLoadBridge<CR> Purpose  To download USB Bridge firmware to 3610. Here is the setup barcode for this serial command: LoadBridge
246 Enter Setup 1664 Barcode Scanner User Guide  EXAMPLE Without using the scanner to read the above setup barcodes for configuring the 3610 dongle, run HyperTerminal.exe on the host computer to send serial commands to 3610 via USB Virtual COM. 1) Connect 3610 to the USB port of PC. 2) The Communication LED will indicate when 3610 can accept serial commands after initializing. Refer to the table below.  If the output interface is USB Virtual COM, run HyperTerminal.exe on the host computer. While the Communication LED on 3610 is purple (red with flashing blue), type the serial command within 3 seconds.  If the output interface is USB HID, press the “Num Lock” or “Caps Lock” key via the keyboard 5 times within 3 seconds while the Communication LED on 3610 is flashing red and blue. This will change the interface from USB HID to USB Virtual COM and the Communication LED will become purple (red with flashing blue). Then, run HyperTerminal.exe on the host computer. While the Communication LED on 3610 is purple (red with flashing blue), type the serial command within 3 seconds. After configuring via serial commands, the interface will reset to USB HID after re-connecting 3610.  Communication LED  Meaning --- Blue, solid  Initialize Red, solid  Blue, flashing  Serial command mode with USB Virtual COM: wait 3 seconds for starting a serial command Red, flashing  Blue, flashing  Serial command mode with USB HID changed to USB Virtual COM first: wait 3 seconds for pressing [Num Lock] or [Caps Lock] 5 times via keyboard
    247 Update   0 1 2 3 4 5 6 7 8 0    F2 SP 0 @ P ` p  1  INS F3 !  1  A  Q  a  q   2  DLT F4  "  2  B  R  b  r   3  Home F5  #  3  C  S  c  s   4  End F6 $ 4 D T d t   5  Up F7 % 5 E U e u  6  Down F8  &  6  F  V  f  v   7  Left F9 '  7  G  W  g  w   8  BS F10 ( 8 H X h x  9  HT F11 )  9  I  Y  i  y   A  LF F12 * : J Z j  z  B  Right ESC + ; K [ k {  C  PgUp Exec , < L \ l |  D  CR CR* - = M ] m }  E  PgDn   .  > N ^ n ~  F  F1   /  ? O _ o Dly ENTER* Note: (1) ~: Digits of numeric keypad.       (2) CR*/Send/ENTER*: ENTER key on the numeric keypad.         Appendix III KEYBOARD WEDGE TABLE
248 Enter Setup 1664 Barcode Scanner User Guide  KEY TYPE & STATUS KEY TYPE If “Bluetooth® HID” or “USB HID” is configured for interface, Key Type and Key Status will then become applicable.   *Normal Scan CodeKEY STATUS Decide whether or not to change key status when “Normal Key” is selected for Key Type.   Add Shift Add Left Ctrl Add Right Ctrl Add Left Alt Add Right Alt
    249 Update  Appendix III  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 EXAMPLE KEY TYPE = NORMAL For example, if you want to program the character “!” as the prefix code: 1.  Read the “Configure Prefix” barcode. 2.  Read the “Hexadecimal Value” barcode on page 252 for “2” and “1”. 3.  Read the “Validate” barcode to complete this setting. KEY TYPE = SCAN CODE For example, if you want to program the character “a” (= “1C” on the scan code table) as the prefix code: 1.  Read the “Configure Prefix” barcode. 2.  Read the “Scan Code” barcode. 3.  Read the “Hexadecimal Value” barcode on page 252 for “1” and “C”. 4.  Read the “Validate” barcode to complete this setting. KEY TYPE = NORMAL + KEY STATUS = SHIFT For example, if you want to program the character “!” (= “Shift” + “1” on keyboard) as the prefix code: 1.  Read the “Configure Prefix” barcode. 2.  Read the “Add Shift” barcode. 3.  Read the “Hexadecimal Value” barcode on page 252 for “3” and “1”. 4.  Read the “Validate” barcode to complete this setting. KEY TYPE = NORMAL + KEY STATUS = CTRL For example, if you want to program “Ctrl+A” and “Ctrl+$” as the prefix code: 1.  Read the “Configure Prefix” barcode. 2.  Read the “Add Left Ctrl” barcode. 3.  Read the “Hexadecimal Value” barcode on page 252 for “4”, “1” (= “A”). 4.  Read the “Add Left Ctrl” barcode. 5.  Read the “Hexadecimal Value” barcode on page 252 for “2”, “4” (= “$”). 6.  Read the “Validate” barcode to complete this setting.
250 Enter Setup 1664 Barcode Scanner User Guide
    251              Update AbortDECIMAL SYSTEM Decimal                Validate the Values                                           Appendix IV NUMERAL SYSTEMS 0  1 2 3 4 5 6 7 8 9 Validate
252 Enter Setup 1664 Barcode Scanner User Guide  HEXADECIMAL SYSTEM Hexadecimal                         0 1 2 3 4  5 6 7 8  9 A  B C D E  F
    253              Appendix IV  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Update AbortValidate the Values   ASCII TABLE  0 1 2 3 4 5 6 7  0   DLE SP 0 @ P ` p  1 SOH DC1 !  1 A Q a q  2 STX DC2 " 2 B R b r   3 ETX DC3 # 3 C S c s  4 EOT DC4 $ 4 D T d t   5 ENQ NAK % 5 E U e u  6 ACK SYN & 6 F V f  v  7 BEL ETB '  7 G W g w  8 BS CAN ( 8 H X h x  9 HT EM ) 9 I Y i  y  A LF SUB * : J Z j  z  B VT ESC + ; K [ k {  C FF FS , < L \ l |  D CR GS - = M ] m }  E SO RS .  > N ^ n  ~  F SI US / ? O _ o DEL          Validate
254 Enter Setup 1664 Barcode Scanner User Guide  ENTERING PIN CODE FOR AUTHENTICATION USE PRESET PIN 1) In the configuration mode, read the barcode below to use a preset PIN for authentication.   Use Preset PIN 2) Read one of the barcodes to specify the PIN code, in decimal or hexadecimal.  By default, the PIN code is set to “0000”. Maximum 16 characters are allowed.   Enter PIN in Hexadecimal… Enter PIN in  Decimal… 3) Read the “Decimal Value” barcode on page 251 or the “Hexadecimal Value” barcode on page 252 for the desired digits or character string.  Read the “Clear PIN Code” barcode first if you need to re-input the PIN code.   Clear PIN Code 4) Read the “Validate” barcode to complete this setting.
    255              Appendix IV  錯誤!  使用 [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 Update AbortDISABLE AUTHENTICATION OR USE RANDOM PIN In the configuration mode, read the barcode below to disable authentication (= No PIN) or use a random PIN for authentication.   *No PIN or  use random PINNote: When using Bluetooth® HID, some device driver may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to “No PIN or use random PIN” before pairing. While pairing, the host PIN code will be displayed on the computer screen.  Use Random PIN When the target device is set to use a random PIN for authentication, wait until the random PIN is displayed on the target device while pairing, and then input the matching PIN code on the scanner. Note: Follow the steps below to enter the matching PIN on the scanner. There is no need to enter the configuration mode!  1.  Read one of the barcodes to specify the PIN code, in decimal or hexadecimal.  Enter PIN in Hexadecimal… Enter PIN in  Decimal…2.  Read the “Decimal Value” barcode on page 251 or the “Hexadecimal Value” barcode on page 252 for the desired digits or character string. Read the “Clear PIN Code” barcode first if you need to re-input the PIN.  Clear PIN Code
256 Enter Setup 1664 Barcode Scanner User Guide  3.  Read the “Validate” barcode to complete this setting. Reject Random PIN Request When the random PIN is displayed on the target device while pairing, you can reject the PIN request by having the scanner read the “Validate” barcode.    Press the pin tip against the connector and release the cable.

Navigation menu