Table of Contents Restore Default Settings .......................................................................................1 Exit Setup without Changes.................................................................................1 Set Connection.......................................................................................................1 RF Auto Shutdown Duration...............................................................................1 Memory Mode Parameters...................................................................................2 List Setting.............................................................................................................3 Buzzer Settings......................................................................................................3 Reading Redundancy Setting...............................................................................4 Scan Mode Setting.................................................................................................4 Auto-Sense Setting ................................................................................................4 Scanner Time-out Duration..................................................................................5 Negative Barcode Setting .....................................................................................5 Delay between Reread ..........................................................................................5 Keyboard Wedge Parameters..............................................................................6 Laptop Support .....................................................................................................8 RS-232 Parameters ...............................................................................................9 Bluetooth Serial Port Parameters......................................................................11 Prefix / Postfix Settings.......................................................................................12 Character Substitution .......................................................................................12 Code ID Selection................................................................................................12 Code ID Setting ...................................................................................................13 Length Code Setting (2 digits)............................................................................14 Select Readable Codes ........................................................................................17 Code39 Parameters.............................................................................................22 Italy Pharmacode Parameters............................................................................22 French Pharmacode Parameters .......................................................................23 Industrial 25 Parameters....................................................................................23 Interleave 25 Parameters....................................................................................24 Matrix 25 Parameters.........................................................................................26 Codabar Parameters...........................................................................................27 Plessey Parameters..............................................................................................28 Telepen Parameters ............................................................................................28 MSI Parameters..................................................................................................29 MSI Parameters..................................................................................................29 EAN128 Parameters ...........................................................................................30 EAN8 Parameters ...............................................................................................31 UPCA Parameters...............................................................................................31 UPCE Parameters...............................................................................................32 EAN13 Parameters .............................................................................................33 RSS Code ID Selection........................................................................................34 RSS14 Parameters...............................................................................................34 RSS Limited Parameters ....................................................................................35 RSS Limited Parameters....................................................................................35 Activate Editing Formats...................................................................................36 Editing Format Parameters ...............................................................................37 Decimal Digits .....................................................................................................49 Hexadecimal Digits .............................................................................................50 RS-232 Character Table.....................................................................................51
 Restore Default Settings  Memory Mode Parameters • Memory Mode      Enable      < Disable > Exit Setup without Changes  •  Clear Data     Clear     Confirm Set Connection * Programming Instructions :  (1) Read the label. (2) Read the Serial Number barcode on the bottom of the desired 3660 Base Station within 5 seconds to complete this setting. • Send Data  • Memory Data Delay RF Auto Shutdown Duration     < 0 >    2 sec  250 ms    3 sec  500 ms    5 sec  1 sec     8 sec * Programming Instructions : (1) Read the label. (2) Program the desired auto shutdown duration (in minutes) by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. 2  Enter Setup 1  Update
 List Setting  Reading Redundancy Setting     Page1    Page 6  Page 2    Page 7  Page 3    Page 8  Page 4    Page 9  Page 5     Page 10     < No Redundancy >    2 Times  3 Times     4 Times Scan Mode Setting     Auto Off Mode    < Continuous Mode >  Auto Power Off Mode    Alternate Mode  Momentary Mode    Repeat Mode  Laser Mode     Test Mode Buzzer Settings     < Buzzer Enable>     Buzzer Disable • Buzzer Frequency  Auto-Sense Setting     8 kHz    < 4 kHz >  2 kHz     1 kHz     Enable      < Disable > 4  Enter Setup 3  Update
 Keyboard Wedge Parameters Scanner Time-out Duration • Activate and Select Keyboard Type * Programming Instructions : (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. * Programming Instructions : (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Negative Barcode Setting  • Keyboard Table     Enable      < Disable > No.    Keyboard Type1   PCAT (US)2   PCAT (French)3   PCAT (German)4 PCAT (Italy) 5   PCAT (Swedish)6   PCAT (Norwegian)7 PCAT (UK) 8   PCAT (Belgium)9   PCAT (Spanish)10   PCAT (Portuguese)11 PS55 A01-1 12   PS55 A01-213   PS55 A01-314   PS55 001-115   PS55 001-8116   PS55 001-217   PS55 001-8218   PS55 001-319   PS55 001-8A20  PS55 002-1, 003-1 21  PS55 002-81, 003-81 22  PS55 002-2, 003-2 23  PS55 002-82, 003-82 24  PS55 002-3, 003-3 25  PS55 002-8A, 003-8A 26  IBM 3477 (Japanese) 27 PS2-30 28  IBM 34XX/319X, Memorex Telex 122 Keys Delay between Reread      100 ms    1 sec  200ms    2 sec  < 400 ms >    3 sec  800 ms     5 sec 6  Enter Setup 5  Update
 • Keyboard Alphabets Layout  • Alphabet Transmission     < Default Layout >    AZERTY    QWERTZ     < Case Sensitive >     Ignore Case • Digits Transmission     < Alphanumeric Key >     Numeric Key • Keyboard Digits Layout     < Default Layout >     Lower Row   Upper Row • Alt Composing     Yes      < No > • Keyboard Capital Lock Type     < Default >     Shift Lock   Capital Lock • Inter-Character Delay * Programming Instructions : (1) Read the label. (2) Program the desired inter-character delay by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. • Capital Lock Setting       Capital Lock ON    < Capital Lock OFF >  Auto Detection Laptop Support     < Disable>     Enable 8  Enter Setup 7  Update
 RS-232 Parameters  • Flow Control      < None >    Scanner Ready  Data Ready      INV. Data Ready • Activate RS232 Interface  • Baud Rate     115200    38400  19200    < 9600 >  4800    2400  1200     300 • Inter-Character Delay * Programming Instructions : (1) Read the label. (2) Program the desired inter-character delay by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. • Parity     Even    Odd   < No Parity > • Data Bit     < 8 >     7 10  Enter Setup 9  Update
  Bluetooth Serial Port Parameters  Prefix / Postfix Settings     Prefix Code *      Postfix Code * • Activate BlueTooth Serial Port Interface  • Device Name Broadcasting  Character Substitution     < Yes >     No      Set 1 *    Set 2 *   Set 3 * • Authentication     Yes      < No > Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits.  (3) Read the “Validate” label (also on page 50) to complete this setting. • PIN Code  Code ID Selection *  • Clear All Code ID Settings Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits.  (3) Read the “Validate” label (also on page 50) to complete this setting. (4) Max 6 characters for this PIN Code setting.  • Select Code ID Set     Set 1    Set 2  Set 3    Set 4  Set 5 12  Enter Setup 11  Update
 Code ID Setting  Length Code Setting (2 digits)     Code 39 *    Italy Pharmacode *  French Pharmacode *    Industrial 25 *  Interleave 25 *    Matrix 25 *  Codabar *    UPCA *  UPCE *    EAN8 *  EAN13 *    Code 93 *  Code 128 *    MSI *  Plessey *       Telepen * • Code 39 Length Code     Enable      < Disable > • Italy Pharmacode Length Code     Enable      < Disable > • French Pharmacode Length Code     Enable      < Disable > • Industrial 25 Length Code     Enable      < Disable > • Interleave 25 Length Code     Enable      < Disable > Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. 14  Enter Setup 13  Update
 • Matrix 25 Length Code  • Code 93 Length Code     Enable      < Disable >     Enable      < Disable > • Code 128 Length Code • Codabar Length Code     Enable      < Disable >     Enable      < Disable > • EAN128/RSS Length Code • UPCA Length Code     Enable      < Disable >     Enable      < Disable > • MSI Length Code • UPCE Length Code     Enable      < Disable >     Enable      < Disable > • Plessey Length Code • EAN8 Length Code     Enable      < Disable >     Enable      < Disable > • Telepen Length Code • EAN13 Length Code     Enable      < Disable >     Enable      < Disable > 16  Enter Setup 15  Update
 Select Readable Codes  • Matrix 25     Enable      < Disable > • Code 39     < Enable >     Disable  • Codabar     < Enable >     Disable • Italy Pharmacode     Enable      < Disable >  • Code 93     < Enable >     Disable • French Pharmacode     Enable      < Disable >  • Code 128     < Enable >     Disable • Industrial 25     < Enable >     Disable  • EAN128     Enable      < Disable > • Interleave 25     < Enable >     Disable  • MSI     Enable      < Disable > 18  Enter Setup 17  Update
 • Plessey  • UPCE     Enable      < Disable >     < Enable No Addon >    Disable No Addon  Enable Addon2    < Disable Addon2 >  Enable Addon5      < Disable Addon5 > • Telepen     Enable      < Disable > • UPCA     < Enable No Addon >    Disable No Addon  Enable Addon2    < Disable Addon2 >  Enable Addon5      < Disable Addon5 > • EAN8     < Enable No Addon >    Disable No Addon  Enable Addon2    < Disable Addon2 >  Enable Addon5      < Disable Addon5 > 20  Enter Setup 19  Update
 Code39 Parameters • EAN13 • Standard / Full ASCII Code39     < Enable No Addon >    Disable No Addon  Enable Addon2    < Disable Addon2 >  Enable Addon5      < Disable Addon5 >     < Standard >     Full ASCII • Start / Stop Transmission     Enable      < Disable > RSS14 • Checksum Verification     Enable      < Disable >     Enable      < Disable > • RSS Limited     Enable      < Disable > • Checksum Transmission     < Enable >     Disable • RSS Expanded     Enable      < Disable > Italy Pharmacode Parameters • Checksum Transmission     < Enable >     Disable> 22  Enter Setup 21  Update
 French Pharmacode Parameters  • Max / Min Code Length Qualification • Checksum Transmission   Select Max / Min Length Qualification     < Enable >     Disable     Max Length *      Min Length * Industrial 25 Parameters  • Fixed Code Length Qualification • Start / Stop Selection  Select Fixed Length Qualification     < Industrial 25 >    Interleave 25  Matrix 25    Fixed Length 1 *      Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. • Checksum Verification     Enable      < Disable >  Interleave 25 Parameters • Start / Stop Selection • Checksum Transmission     Industrial 25    < Interleave 25 >  Matrix 25     < Enable >     Disable 24  Enter Setup 23  Update
 • Checksum Verification  • Fixed Code Length Qualification     Enable      < Disable >  Select Fixed Length Qualification    Fixed Length 1 *      Fixed Length 2 * • Checksum Transmission     < Enable >     Disable Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. • Max / Min Code Length Qualification  Matrix 25 Parameters  Select Max / Min Length Qualification  • Start / Stop Selection     Industrial 25    Interleave 25   < Matrix 25 >    Max Length *      Min Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.  • Checksum Verification     Enable      < Disable > • Checksum Transmission     < Enable >     Disable 26  Enter Setup 25  Update
 • Max / Min Code Length Qualification  • Start / Stop Selection     < abcd / abcd >    abcd / tn*e  ABCD / ABCD      ABCD / TN*E  Select Max / Min Length Qualification    Max Length *      Min Length * • Fixed Code Length Qualification  Plessey Parameters  Select Fixed Length Qualification  • Convert to UK Plessey    Fixed Length 1 *      Fixed Length 2 *     Enable      < Disable > • Checksum Transmission Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.      < Enable >     Disable Codabar Parameters Telepen Parameters • CLSI Conversion     Enable      < Disable > • Telepen Output     < AIM Telepen >      Original Telepen • Start / Stop Transmission     Enable      < Disable >  28  Enter Setup 27  Update
 MSI Parameters  • Fixed Code Length Qualification • Checksum Verification   Select Fixed Length Qualification     < Single Modulo 10 >    Double Modulo 10   Modulo 11 & 10    Fixed Length 1 *      Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. • Checksum Transmission     < Last digit not Transmitted >    Transmitted   Last 2 Digits not Transmitted EAN128 Parameters • Code ID Transmission     Enable      < Disable > • Max / Min Code Length Qualification  Select Max / Min Length Qualification  • Field Separator    Max Length *      Min Length * * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. 30  Enter Setup 29  Update
 EAN8 Parameters  UPCE Parameters • Convert to EAN13  • System Number Selection     Enable      < Disable >     System Number 0 and 1      < System Number 0 only > • Checksum Transmission  • Convert to UPCA     < Enable >     Disable     Enable      < Disable > • System Number Transmission UPCA Parameters     Enable      < Disable > • Convert to EAN13     < Enable >     Disable  • Checksum Transmission     < Enable >     Disable • System Number Transmission     < Enable >     Disable • Checksum Transmission     < Enable >     Disable 32  Enter Setup 31  Update
 EAN13 Parameters  RSS Code ID Selection • ISBN Conversion     ]C1      <  ]e0  >     Enable      < Disable >  RSS14 Parameters • ISSN Conversion • Code ID Transmission     Enable      < Disable >     < Enable >     Disable • Checksum Transmission • Application ID Transmission     < Enable >     Disable     < Enable >     Disable • Checksum Transmission     < Enable >     Disable 34  Enter Setup 33  Update
 RSS Limited Parameters  Activate Editing Formats • Code ID Transmission  • Format 1     < Enable >     Disable     Enable      < Disable > • Application ID Transmission  • Format 2     < Enable >     Disable     Enable      < Disable > • Checksum Transmission  • Format 3     < Enable >     Disable     Enable      < Disable > • Exclusive Data Editing RSS Limited Parameters     Yes      < No > • Code ID Transmission     < Enable >     Disable  • Apply Editing Format to Telepen     < Yes >     No 36  Enter Setup 35  Update
 Editing Format Parameters  • Applicable Data Length     Maximum Length *      Minimum Length * • Format Selection     Format 1    Format 2  Format 3 Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. • Matching String of Applicable Data • Restore Default Format *  Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. • Location of Matching String * Programming Instructions : (1) Read the label. (2) Program the desired location by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. 38  End of Format Programming 37  Update
 • Total Number of Fields  • Applicable Code Type     1    4  2    5  3     6     All    Clear  Code 39    Italy Pharmacode  French Pharmacode    Industrial 25  Interleave 25    Matrix 25  Codebar    Code 93  Code 128    EAN128 / RSS  UPCE No Addon    UPCE Addon2  UPCE Addon5    EAN8 No Addon  EAN8 Addon2     EAN8 Addon5 40  End of Format Programming 39  Update
 • Field1 Setting     EAN13 No Addon    EAN13 Addon2  EAN13 Addon5    UPCA No Addon  UPCA Addon2    UPCA Addon5  MSI     Plessey Divide Field by  Field Terminating String  Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.    Include Terminating String      Discard Terminating String Divide Field by Field Length  Field Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. 42  End of Format Programming 41  Update
 • Field2 Setting  • Field3 Setting Divide Field by  Field Terminating String Divide Field by  Field Terminating String  Field Terminating String *   Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.    Include Terminating String      Discard Terminating String    Include Terminating String      Discard Terminating String Divide Field by Field Length Divide Field by Field Length  Field Length *   Field Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. 44  End of Format Programming 43  Update
 • Field4 Setting  • Field5 Setting Divide Field by  Field Terminating String Divide Field by  Field Terminating String  Field Terminating String *   Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.    Include Terminating String      Discard Terminating String    Include Terminating String      Discard Terminating String Divide Field by Field Length Divide Field by Field Length  Field Length *   Field Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. 46  End of Format Programming 45  Update
 • Additional Fields Setting  • Field Transmission Sequence     Additional Field 1 *    Additional Field 4 *  Additional Field 2 *    Additional Field 5 *   Additional Field 3 *  Start    Field 1    Additional Field 1  Field 2    Additional Field 2  Field 3    Additional Field 3  Field 4    Additional Field 4  Field 5    Additional Field 5  Field 6 Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.  End Programming Instructions : (1) Read the “Start” label. (2) Program the desired transmission sequence by reading the Field / Additional Field labels. (3) Read the “End” label to complete this setting. 48  End of Format Programming 47  Update
 Decimal Digits  Hexadecimal Digits     0    5  1    6  2    7  3    8  4     9     0    8  1    9  2    A  3    B  4    C  5    D  6    E  7     F • Validate  • Validate  49  Update  50  Enter Setup
  RS-232 Character Table    3450  1 2 6 7       0    DLE SP 0 @ P ` p1     SOH DC1 !  1 A Q a q2           STX DC2 " 2 B R b r3           ETX DC3 # 3 C S c s4       EOT DC4 $ 4 D T d t5       ENQ NAK % 5 E U e u6       ACK SYN & 6 F V f v7       BEL ETB ' 7 G W g w8      BS CAN ( 8 H X h x9           HT EM ) 9 I Y i yA           LF SUB * : J Z j zB           VT ESC + ; K [ k {C         FF FS , < L \ l |D         CR GS - = M ] m }E           SO RS . > N ^ n ~F       SI US / ? O _ o DEL                     51  Update