Chromagic Technologies HSP02 PIR motion sensor User Manual HSP02 UserManual

Chromagic Technologies Corporation PIR motion sensor HSP02 UserManual

user manual

 1HSP02  MOTION DETECTOR  The Motion Detector is a Z-WaveTM enabled device which is fully compatible with any Z-WaveTM enabled network.  Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-WaveTM enabled networks.  This Motion Detector can control our modules via controller setting.  Inclusion of this Motion Detector on other manufacturer’s Wireless Controller menu allows remote turn-on of connected modules when the detector is triggered.  The Motion Detector is designed with two detecting sensors, Passive Infra-Red (PIR) sensor and light sensor, in order to fulfill the purpose of security and home automation.    When the detector is cooperated with security appliances, it is acting as a security device by detecting changes in infra-red radiation levels.    If a person moves within or across the device field of vision, a trigger radio signal will be transmitted to cause full alarm condition in order to frighten intruders away. Alternatively, when the detector is worked with home automation appliances, the detector can be set to perform the role of home automation device by detecting both changes in infra-red radiation levels and percentage of lux levels.    Once night falls, the percentage of ambient illumination is lower than preset value.  If a person moves within or across the device field of vision, a trigger radio signal will be transmitted so as to turn on the connected lightings for better illumination.  Two mounting methods are provided for varying detection range.    The detector can be mounted on a wall for farther detecting distance but narrower coverage; while for ceiling mounting, shorter detecting distance can be made but desired coverage can be expected at user’s disposal.    Product Overview             Include to or Exclude from Z-WaveTM Network  In the rear casing, there is a link key which is used to carry out inclusion, exclusion, association or reset.  When the detector is first powered up, the LED flashes on and off alternately and repeatedly at 2-second intervals.   It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices.    Please get familiar with the terms below before starting the operations.  Function Description Inclusion   Add a Z-Wave enabled device (e.g. Motion Detector) to Z-Wave network. Exclusion   Delete a Z-Wave enabled device (e.g. Motion Detector) from the network. Association  After inclusion, you have to define the relationship between devices. Trough association, device can be assigned as master/slave, and specify which slave is going to be controlled by which master. Reset Restore Detector to factory default.  The table below lists an operation summary of basic Z-Wave functions.  Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the setup function, and to include/exclude/associate devices.  Function Description  Indication No node ID  The Z-Wave Controller does not allocate a node ID to the unit.  2-second on, 2-second off 1.  Have Z-Wave Controller entered inclusion mode. Inclusion 2.    Pressing link key 3 times within 1.5 second will enter inclusion mode.   The Detector will stay “awake” for 5 minutes to allow time for setting and device status enquiring. Detector beeps when link key is pressed. 1.  Have Z-Wave Controller entered exclusion mode. Exclusion 2.  Pressing link key 3 times within 1.5 second will enter exclusion mode.   The Detector will stay “awake” for 5 minutes to allow time for setting and device status enquiring.     Detector beeps when link key is pressed. 1.  Press link key 3 times within 1.5 second.  Detector beeps when link key is pressed. 2.  Within 1 second, press and hold link key until beep stops.  A long beep is sounded for 5 seconds. Reset 3.  IDs are excluded and all of preset value will be reset to factory default.  2-second on, 2-second off
 2Function Description  Indication 1.    Have Z-Wave Controller entered association mode.  2.    When pressing link key 3 times within 1.5 seconds will enter association mode.  Detector beeps when link key is pressed. Association 3.    There are two groupings – 1 and 2.   Refer to Z-Wave’s Grouping as described on page 4.  Including a node ID allocated by Z-Wave Controller means inclusion.    Excluding a nodeID allocated by Z-Wave Controller means exclusion. Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller.  Choosing a Mounting Location  The Motion Detector can be mounted either on a wall.    Before selecting a position for Motion Detector, the following points should be noted:   1.  Do not position the detector facing a window/fan/air-conditioner or direct sunlight.  2.  Do not position the detector directly above or facing any source of heat, e.g. fires, radiators, boiler etc.  3.  Ensure the detector is positioned in place where the light source detected by the detector is consistent with actual ambient illumination.  Do not locate the detector in a shadowy place.   4.  Where possible, mount the detector so that the logical path of an intruder would cut across the fan pattern rather than directly towards the detector (FIGURE 1).  5.  For best results, locate the detector directly facing an entrance.           Installation  Ensure that the system is in Test Mode.  1.  Undo and remove the fixing screw from the bottom edge of the detector. Carefully pull the bottom edge of the detector away from the rear cover and then slide down to release the top clips. (FIGURE 2)               FIGURE 2 2.  Carefully drill out the required mounting holes in the rear cover using 3mm drill according to whether the unit is being mounted in a corner or against a flat wall.  Note: Using 1st mounting hole to fulfill corner mounting installation, while 2nd mounting hole for flat wall installation. (FIGURE 3a & 3b)                 FIGURE 3a FIGURE 1
 3                   Corner mounting FIGURE 3b 3.  Using the rear cover as a template, mark the positions of the fixing holes on the wall.  4.  Fix the rear cover to the wall using the two 18mm No.4 screws and 25mm wall plugs, (a 5mm hole will be required for the wall plugs).    Do not over-tighten the fixing screws as this may distort or damage the cover.  5.  Configure the detector as described below.  Remember that on initial installation that the device needs to be tested.  6.  Check that the detector PCB is located and set in the correct position to provide the required detection range.    To adjust the PCB position, simply slide it up or down ensuring that the location legs are aligned with the required position number marked on the board.  7.  To refit the detector to the rear cover and locate the clips in the top edge into the rear cover.    Push the lower edge of the detector into place and refit the fixing screw in the bottom edge of the detector to secure in position.  Do not over-tighten the fixing screws as this may damage the casing.      Settings  Warm-Up  It will take approximately 2 minutes to warm up after battery has been connected.  During this period, the red LED will flash in every 3 seconds. When the red LED turns on steadily for 5 seconds, it implies warm-up procedure is completed and the detector is ready for detection.  Operation Wall Mounting  1.  By walking into a protected area within coverage of 110 degrees, the detector will now be triggered each time the detector senses movement. The orange LED on the detector will be illuminated and the associated appliances will be activated.  For example, siren will be sounded or indication of movement detection will be shown on the controller.  It implies that the unit is working properly.    Programming  1.  Z-Wave’s Group (Association Command Class Version 1)  The unit supports two association groups with one node support for Grouping 1 and three nodes support for Grouping 2.  This has the effect that when the unit is triggered, all devices associated with the unit will receive the relevant reports.  There are two kinds of reports: ALARM_REPORT and   SENSOR_BINARY_REPORT.  1-1 Grouping 1 (Max. node = 1) 1-1-1 Power Applied Command  The unit will send ALARM_REPORT command to the nodes of Grouping 1 to inform the device that the unit is powered up.  ALARM_REPORT Command: [Command Class Alarm, Alarm Report, Alarm Level = 0x02, Alarm Type = 0x01]  1-1-2  Intrusion Event Report (Binary Sensor Report)  Once the Detector detected a movement, the unit will send SENSOR _ BINARY_REPORT to the nodes of Grouping 1 to inform there is an
 4intrusion event.  Once the movement is stopped, SENSOR_ BINARY_REPORT will be sent again to the associated devices.  BINARY SENSOR REPORT Command: Event Present: [Command Class Sensor Binary, Sensor Binary Report, Value = 255 (0xFF)] Event Clear: [Command Class Sensor Binary, Sensor Binary Report, Value = 0 (0x00)]  1-1-3  Low Battery Report (Alarm Report Class)  Upon Detector status being changed, the unit will check its battery status simultaneously.    When the battery level of the unit drops to an unacceptable level, the unit will flash red LED once every 30 seconds, and every 20 minutes emit ALARM_REPORT command to the nodes of Grouping 1.  ALARM_REPORT Command: [Command Class Alarm, Alarm Type = 0x01, Alarm Level = 255(0xFF)]  1-2 Grouping 2 (Max. node = 3)  1-1-2 Control other Z-Wave Devices      When the detector is triggered, the unit will send BASIC_SET command which contains a value that is adjustable, to the nodes of Grouping 2.  For instance, the brightness level of a lamp module can be fixed according to the set value. However, the BASIC_SET command will also be sent to the nodes of Grouping 2.  For instance, a lamp module will be turned off after receiving the BAISC_SET command.  Basic Set Command: Event Present: [Command Class Basic, Basic Set, Value = 255 (0xFF)] Event Clear: [Command Class Basic, Basic Set, Value = 0 (0x00)]  2. Z-Wave’s Configuration  The following information is for someone that has some experience in setting up a Z-Wave system or someone that has computer software running a Z-Wave controller.  Please get familiar with software of Z-Wave controller before getting started.  2-1 Basic Set Level  When Basic Set Command is sent where contains a value, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set command of which value is decisive as to how bright of dim level of lamp module shall be.  Example: 1-99: ON      (Binary Switch Device)   Dim  Level   (Multilevel Switch Device)  Function Parameter Number Size Range Default Basic Set level  1  1  1 ~99  99 Configuration Command  2-2 Enabling/Disabling Sensor Detecting Function  There might be times when users wish to suspend the detecting functions of the detector temporarily.    By using Configuration Parameter #2, the detecting function can be set as enable or disable, where configured with the value of 0 means disable and 1 means enable.  Function Parameter Number Size Value Default Enable/Disable Detecting  2  1  0 or 1  1 Configuration Command  Note: Reconnection of power supply will enable the sensor detecting function automatically.   2-3 Sensitivity Level (PIR sensor only)  In order to provide a best efficiency of the detector, it is recommended to test the detector with movements from a farthest end of the coverage area at first 20 secondsDetected a movement Detected a movement Detected a movement(no response)TriggereTriggered
 5time of use.   If movements cannot be detected sensitively, simply adjust the sensitivity level with Configuration Parameter #3. This parameter can be configured with the value of 1 through 10, where 1 means low sensitivity and 10 means highest sensitivity.  Function Parameter Number Size Range Default Sensitivity Level  3  1  1~10  6 Configuration Command  2-4 Re-trigger Interval Setting (PIR sensor only)  The Configuration parameter that can be used to adjust the interval of being re-triggered after the detector has been triggered as Configuration Parameter #4.    No response will be made during this interval if a movement is presented.   The time interval can be set between 5 secs to 3600 secs.  Function Parameter Number  Size  Range DefaultRe-trigger Interval 4  1 or 2 (if value > 127) 5~3600(sec)  5   Note: The orange LED is on for one second when the detector detects a trigger.  2-5 Lux Level  The user can set a detecting percentage of lux level which determines when the light sensor will be activated.  If percentage of lux level of ambient illumination falls below this percentage, and a person moves across or within the protected area, the detector will emit Z-Wave ON Command (i.e. Basic Set Command (Value = Basic Set Level)) to controller and activate connected modules and lighting.    Percentage can be set between 1% to 100%.       Function Parameter Number Size Range DefaultLux Level  5  1 1~100 %  10 Configuration Command      2-6 On-Off Duration  The function of on-off duration setting will be useful if the detector is connected with a module or lighting.  The duration determines how long the module/lighting should stay ON.  For instance, Lamp Module turns off 100 secs after it has been turned on.    This parameter can be configured with the value of 5 through 3600, where 5 means 5 second delay and 3600 means 3600 seconds of delay.  Function Parameter Number Size  Range Default On-Off Duration  6  1 or 2 (if value > 127)5~3600 (sec) 5 Configuration Command        Note: The green LED will stay on for 1 second after 15 seconds of interval.  3. Advanced Programming  3-1 Battery Check Command  The users can also enquire the battery status of the Detector by sending BATTERY_ GET command via Z-Wave Controller.  Once the unit receives the command, it will return BATTERY_REPORT command.  If the unit is in low battery status, a Battery_Level = 255 (0xFF) command will be sent to the Z-Wave Controller. BATTERY_REPORT Command [Command Class Battery, Battery Report, Battery Level = 20%-100%]  3-2 Wakeup Command Class  The detector stays in sleep status for the majority of time in order to conserve battery life.   However, it can be woken up by either triggers of movement or by setting WAKE_UP_INTERVAL_SET command via Z-Wave Controller.  After the unit wakes up, it will send Wakeup Notification Command to the node ID that requires to be reported. The minimum and maximum wakeup interval is Detected a movement5 secondsDetector is triggered Light turns on Light turns off
 660 seconds and 194 days respectively. Allowable interval among each wakeup interval is 1 second, such as 60, 61, 62 ….  Note: The default value is 1 day, which implies that the detector awakes and sends the Wakeup Notification Command to the set node every day.      Command Classes  The Motion Detector supports Command Classes including…  * COMMAND_CLASS_BATTERY * COMMAND_CLASS_VERISON * COMMAND_CLASS_WAKE_UP    * COMMAND_CLASS_ASSOCIATION * COMMAND_CLASS_CONFIGURATION * COMMAND_CLASS_SENSOR_BINARY * COMMAND_CLASS_MANUFACTURER_SPECIFIC ---For Control Other Devices--- * COMMAND_CLASS_BASIC     Troubleshooting  Symptom Possible Cause Recommendation Run out of battery power  Replace a new battery  LED cannot be displayed Check if reverse battery polarity  Refit the battery with correct polarity Reposition its mounting location Check if mounting location is proper Remove the source of interference The detector not working Check if the detector is out of order  Do not open the detector; send it to the local retailer.Symptom Possible Cause Recommendation Two minutes warm up is completed, but cannot hear long beep sound (LED flashes on & off repeatedly at 2-second intervals) Check if detector is first power up or the detector has executed exclusion or reset procedure  Please carry out inclusion procedure; make sure there are ID codes stored in the detector. The detector does not stay awake for 10 minutes  Check if detector is out of order    Please make sure link key is pressed 3 times within 1.5 sec. If detector still fails to stay awake for 10 seconds, repeat this step until it is succeeded.  Specifications  Battery  ER14250 3.6V Lithium Battery Operating Range  Minimum 30 m line of sight Warm Up Time  About 2 minutes PIR Detection Coverage    Wall-Mounted: Up to 10m x 110°  (at 1.8m mounting height & 25°C) Operating Frequency  908.42 MHz (US) / 868.42 MHz (EU) ZDK Version  V5.02 *Specifications are subject to change without notice                                                     Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.    These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: -  Reorient or relocate the receiving antenna. -  Increase the separation between the equipment and receiver. -  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help.  This device complies with Part 15 of the FCC Rules. Operation is subject to the
 7following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.  This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  WARNING: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.    Contact your local government for information regarding the collection systems available.  If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.  When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge.