Chaney Instrument VN1TXCA2 Professional Weather Center User Manual

Chaney Instrument Co. Professional Weather Center Users Manual

Users Manual

Instruction ManualSAVE THIS MANUAL FOR FUTURE REFERENCE.Questions? Contact Customer Support at (877) 221-1252 or visit www.AcuRite.com.CONTENTSUnpacking Instructions ........... 2Package Contents .................. 2Product Registration ............... 2Features & Benets: 5-in-1 ....... 3Features & Benets: Display .... 4Setup .................................... 75-in-1 Sensor Setup ................ 7Display Unit Setup ................. 8AcuRite Connect .................... 9 Set the Time, Date & Units .....10Backlight Settings ..................10 Placement Guidelines ............115-in-1 Sensor Installation ........ 12Using the Weather Center .....13Rainfall Tracking ...................14Weather Ticker .....................15Troubleshooting ....................16Care & Maintenance ............. 19Calibration .......................... 20Specications ........................21FCC Information ...................21Customer Support ................ 22Warranty............................. 22Professional Weather Centermodel 02064C / 999143
2 3Congratulations on your new AcuRite product. To ensure the best  possible product performance, please read this manual in its entirety  and retain it for future reference.Unpacking InstructionsRemove the protective lm that is applied to the LCD screen prior to using this  product. Locate the tab and peel off to remove. Package Contents1. Display unit with tabletop stand 2. 5-in-1 sensor 3. Sensor mounting bracket 4. Mounting hardware  5. Power adapter 6. USB cable 7. 4 alkaline batteries8. Instruction ManualFeatures & BenetsPRODUCT REGISTRATIONRegister online  to receive 1 year  warranty protectionwww.AcuRite.comIMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE►Register a Product7218105611435-in-1 SENSOR1.   Rainfall Collector Funnel2.   Solar Cell Panel   Converts sunlight into power to run   internal aspirating fan.  Internal Aspirating Fan   (not shown)  Draws ambient air into      sensor to reduce solar radiation    heating, resulting in more accurate    temperature measurement.3.   A-B-C Switch   ID code that must match display’s    A-B-C switch to ensure units   synchronize.4.   Battery Compartment5.   Temperature & Humidity Sensors   (internal)6.   Mounting Point7.    Wind Speed Anemometer8.   Wind Direction Vane9.   Mounting Bracket10.  Mounting Hardware    Includes anchors & screws. Qty    Diameter    Length  5          #4           3/4”  1          #4           1/2”  1          #6           1/2”11.  Debris Filter   Pre-installed to prevent debris from    entering the rain gauge.9
4 5Features & BenetsDisplay Unit1.  Previous 2 Wind Directions 2.  Backlight Button For momentary backlight and  dimmer settings.3.  Current Wind Speed4.  Current Wind Direction5.  Peak Wind Speed Highest speed from the last  60 minutes.6.  High Wind Speed Icon Indicates peak wind speed is greater than 50 MPH (81 KPH).7.  Current Indoor Temperature Arrow icon indicates direction temperature is trending.8.  High Indoor Humidity Icon Indicates indoor humidity level is greater than 75% RH.9.  Current Indoor Humidity  Arrow icon indicates direction humidity is trending.10. Humidity Level Indicator Indicates a high, low, or ideal indoor humidity comfort level.11.  Low Indoor Humidy Icon Indicates indoor humidity level is below 16% RH.12. Display Low Battery Icon13. Clock14. Rainfall Displays rainfall total for TODAY, this WEEK, or this MONTH.15. Today’s Rain Indicator Illustrates rainfall collection up to 1 inch (25 mm).16. 12 to 24 Hour Weather Forecast Self-Calibrating Forecasting pulls data from your 5-in-1 sensor to generate your personal forecast.17.  Rainfall History Displays historical rainfall totals (see page 14).18. Barometric Pressure  Arrow icon indicates direction pressure is trending.19. “     “ Button Changes the rainfall data being displayed (#17).20. “ ” Button  For setup preferences and manually cycling through Weather Ticker messages.21. “ ” Button for setup preferences.22. “ ” Button For setup preferences and manually cycling through Weather Ticker messages.23. “ ” Button Changes the WEATHER SELECT category (#25) being displayed.24. Weather TickerTM Streams real-time data (see page 15).25. WEATHER SELECT Displays high/low records and seasonal data (see page 13).26.   AUTO DIM Icon Indicates display is in auto-dimming brightness mode. (see page 10)27. Date28. Current Outdoor Humidity Arrow icon indicates direction humidity is trending.29. Average Wind Speed  Taken from all wind speed readings over the past 2 minutes.30. 5-in-1 Sensor Signal Strength 31. Sensor Low Battery Icon32. Current Outdoor Temperature  Arrow icon indicates direction temperature is trending.1 432 75 6293124262728303289111214151718161013192021222325
6 7A B CSETUP5-in-1 Sensor Setup1A-B-C SwitchSet to match display unit2Install Batteries 4 AA Batteries3Rain Gauge StabilizerRemove and discardSet the A-B-C SwitchLocate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the sensor and the display unit in order for the units to synchronize. Install or Replace BatteriesBatteries MUST be installed for this product to operate. AcuRite recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.The 5-in-1 sensor requires lithium batteries in low temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the 5-in-1 sensor for temperatures below -4ºF / -20ºC.1. Slide off the battery       compartment cover. 2. Insert 4 x AA batteries into the   battery compartment, as    shown. Follow the polarity    (+/-) diagram in the battery   compartment.3. Replace the battery cover.Remove Rain Gauge StabilizerLocate and remove the rain gauge stabilizer (plastic tab) taped into the bottom of the sensor. The rain gauge will not function until this is removed.231Back of Display Unit34BACK OF DISPLAY UNIT1.  Plug-in for Power Adapter 2.  Plug-in for USB Cable3.  Integrated Keyhole    for easy wall mounting.4.  MAC ADDRESS   12 digit unique ID required for    online connectivity functions.5.  Backup Battery Compartment 6.  A-B-C Switch   ID code that must match 5-in-1    sensor’s A-B-C switch to ensure    units synchronize.7.  CLEAR RECORD / RESET Button    Press to clear data recorded    since 12:00 am. Press and HOLD    for full reset to factory defaults.8.  Power Adapter9.  USB Cable for PC Connection10.  Battery Compartment Cover    (not  shown)############1289675
8 9Display Unit SetupSet the A-B-C SwitchThe A-B-C switch is located inside the battery compartment. It can be set to A, B or C. However, you must select the same letter choices for both the sensor and the display unit in order for the units to synchronize.Plug Power Adapter into Electric   OutletWrite Down the MAC ADDRESS 12 digit unique ID needed for online connectivity functions.  Install or Replace Backup Batteries (optional)Insert 3 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment. PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in re, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.23414Install Backup Batteries 3 AA Batteries3Write Down  MAC ADDRESS  12 digit numberA B C1A-B-C Switch set to match sensorIMPORTANT: Batteries are a backup power source to preserve records in the event of a power outage. Power adapter is the recommended primary power source to enjoy the full functionality of this product.2Plug in Power AdapterAcuRite ConnectAcuRite Connect works with Windows PC’s to provide access to your Weather Center data in the following ways:• Data File: Display unit logs (or stores) data so that you can download it to a     PC in a data le (CSV, or comma-separated values le).• Web Browser or Smartphone: Monitor sensor data remotely using AcuRite’s    free AcuRite online software, or from a mobile device using the free AcuRite    app, available from the iOS App Store or Google Play Store.24 C8 6EDownload the SoftwareThe AcuRite Connect software is available online as a free download. A manual (PDF) is included with the software download.Download AcuRite Connect software to your computer by visiting:http://www.acurite.com/kbase/downloads/Or, navigate to the link above using the following path: www.acurite.com > Support > DownloadsClick the .exe le that was downloaded in step 1, and follow the on-screen instructions to install the software. A folder named “AcuRite Weather Station” will be installed on the computer.After AcuRite Connect is installed on the computer, open the AcuRite Connect app. Verify that the display unit is ON with the power adapter plugged in. Next, connect the mini-USB (small end of the cable) into the USB port on the display, located inside the battery compartment.Connect the USB (larger end of the cable) into a USB port on a Windows computer.  AcuRite Connect is installed and ready for use. Follow the instructions within the AcuRite Connect app to complete setup and begin using the software.1234(PC)
10 11Placement for Maximum AccuracyAcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product.Display Unit PlacementPlace the display unit in a dry area free of dirt and dust. To ensure accurate temperature measurement, place out of direct sunlight and away from heat sources or vents. Display unit stands upright for tabletop use or is wall-mountable.5-in-1 Sensor PlacementThe 5-in-1 sensor is designed to remain outdoors all year long. Choose an open location with no obstructions above or around the sensor for the most accurate measurements.Important Placement GuidelinesDisplay unit and sensor must be within 330 feet (100 meters) of each other. MAXIMIZE WIRELESS RANGE Place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.PREVENT WIRELESS INTERFERENCE Place units at least 3 feet (90 cm) away from electronic devices (TV, computer, microwave, radio, etc.).LOCATE AWAY FROM HEAT SOURCESPosition sensor away from heaters, air conditioners, chimneys, exhaust vents, asphalt and concrete (surfaces that radiate heat).LOCATE AWAY FROM HUMIDITY SOURCESAvoid installing the sensor near pools, spas, or other bodies of water. Water sources may impact humidity accuracy. LOCATE AWAY FROM SPRINKLER HEADSDO NOT install the sensor where it will be sprayed by a sprinkler system. This may force water inside the sensor.LOCATE AWAY FROM WIND & RAIN OBSTRUCTIONSDO NOT mount the sensor with obstructions around it.  Consider a location that is a wide open area, with few  structures around to ensure accurate wind measurement.Visit us online to view installation photos and  video, or learn more about AcuRite technology:  www.AcuRite.com/5in1 View VideoSet the Time, Date & UnitsPress the “   ” button, located on the front of the display unit, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display.To adjust the currently selected (ashing) item, press and release the “ “ or  “  “ buttons (press and HOLD to fast adjust).To save your adjustments, press and release the “   ” button again to adjust the next preference. The preference set order is as follows:LANGUAGE (English, French, Spanish) TIME ZONE (AST, EST, CST, MST, PST, AKST, HAST, NST, AEST, ACST, AWST) AUTO DST CHANGE (YES, NO) WEATHER TICKER SPEED (SLOW, MEDIUM, FAST) CLOCK HOUR CLOCK MINUTE CALENDAR MONTH** CALENDAR DATE** CALENDAR YEAR TEMPERATURE UNITS (oF or oC) WIND SPEED UNITS (MPH, KPH, Knots) RAINFALL UNITS (inches or mm) PRESSURE UNITS (inHg or hPa)*If you live in an area that observes daylight saving time, DST should be set to YES, even if it is not currently Daylight Saving Time. You will automatically exit SET MODE if no buttons are pressed for 20 seconds. Enter setup mode at any time by pressing the “   ” button.Display Backlight SettingsThis weather station’s color display features three different lighting settings: High (100%) brightness, Medium (60%) brightness and Low (15%) brightness.Using battery power alone, the backlight is available momentarily for 10 seconds by pressing the “ ” button.When display is powered with the power adapter, backlight remains on at 100% brightness. Press “ ” button once to dim to 60% brightness; press again to dim to 15%, press a 3rd time to enter “AUTO DIM” mode. “ ” icon appears to the left of the time to indicate that auto-dim mode is ON.AUTO DIM MODE: Automatically adjusts display brightness based on time of day. 6:00 a.m. - 9:00 p.m. = 100% brightness 9:01 p.m. - 5:59 a.m.= 15% brightness
12 135-in-1 Sensor Installation GuidelinesINSTALLATION HEIGHT Mount the sensor at a minimum height of 5 feet (1.5 meters) off the ground, in an open area. Higher is better for wind measurements- the National Weather Service recommends 33 feet  (10 meters) high! MOUNTING OPTIONS The included mounting bracket is designed to screw directly onto wooden posts or surfaces that are 2”x 4” or larger. The  sensor can also be mounted directly to 3/4” steel pipe (available at  hardware stores and home centers).SOLAR CELL INSTALLATION Install the sensor with the solar cell facing SOUTH. This ensures the cell receives as much sun as possible and orients wind direction.5-in-1 Sensor Installation1.  Fasten mounting base (included) to a post or pole (not included) using the 4 longer screws included in the hardware bag.2.  Insert the mounting base into the hole on the bottom of the sensor.3.  Make sure the arrows on the top of the sensor are pointed in the proper direction and the bubble level is centered. The solar cell should be facing south to properly orient the wind direction.4.  Fasten the sensor into the mounting base using the 2 shorter screws included in the hardware bag.The 5-in-1 sensor is now ready to use.Clear Data Collected During InstallationWhen installation is complete, clear erroneous data from the display unit by pressing the “CLEAR RECORD/ RESET” button, on the back of the display inside the battery compartment. This button will clear data recorded since 12:00 am.Basic Setup is CompleteThe 5-in-1 sensor will now synchronize with the display unit. It may take a few minutes for synchronization to complete. If both or one of the units appear to be functioning improperly, please refer to the troubleshooting section.SOUTH(1.5 meters)NO OBSTRUCTIONSABOVE OR AROUNDOPERATIONUsing the Professional Weather CenterLearning ModeSelf-Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction. Weather ForecastAcuRite’s patented Self-Calibrating Forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard. It generates a forecast with pinpoint accuracy - personalized for your exact location. View the complete list of icons at www.AcuRite.com/acurite-iconsWeather SelectWeather Select displays data including wind chill, dew point, heat index,  24-hour change in outdoor temperature and humidity, today, month and all-time high and low records for outdoor temperature, outdoor humidity and peak wind speed. To change the “Weather Select” category shown, press the “ ” button on the front of the display. Barometric PressureSubtle variations in barometric pressure greatly affect the weather. This weather center displays the current pressure with an arrow icon to indicate the direction the pressure is trending (FALLING, STEADY, or RISING).SNOW / RAINMIX LIKELYRAINLIKELYSNOWLIKELYSTORMY& WINDYCLOUDY(flashing=stormy)
14 15Rainfall TrackingThis weather station features enhanced tracking of historical rainfall data. Rain accumulation data is displayed for the current day, week, or month (most recent rainfall total). The rain indicator illustrates today’s rain collection up to 1 inch (25 mm).Press the “   ” button to review historical rainfall records.  Records are shown in the following order:CURRENT YEAR TOTAL (default) PREVIOUS DAILY TOTALS (up to 3 days prior) MONTHLY TOTALS WITH RAIN FOR CURRENT YEAR YEARLY TOTALS FOR PREVIOUS YEARS (up to 4 years) ALL-TIME TOTALWeather Ticker™The Weather Ticker automatically ashes your real-time weather information and alerts as text in the lower part of the display unit screen. The possible WEATHER TICKER messages are as follows:HEAT INDEX-XX WIND CHILL-XX DEW POINT-XX IT FEELS LIKE XX OUTSIDE TODAY’S HIGH HUMIDITY...OUTDOOR XX /  INDOOR XX TODAY’S LOW HUMIDITY...OUTDOOR XX /  INDOOR XX TODAY’S HIGH TEMP...OUTDOOR XX /  INDOOR XX TODAY’S LOW TEMP...OUTDOOR XX /  INDOOR XX 7 DAY HIGH TEMP. XX - MM/DD 7 DAY LOW TEMP. XX - MM/DD 30 DAY HIGH TEMP. XX - MM/DD 30 DAY LOW TEMP. XX - MM/DD ALL TIME HIGH TEMP. XXX...RECORDED MM/DD/YY ALL TIME LOW TEMP. XXX...RECORDED MM/DD/YY 24 HOUR TEMP. CHANGE +XX ALL TIME HIGH WIND XX MPH...RECORDED MM/DD/YY 7 DAY AVERAGE WIND XX MPH TODAY’S AVERAGE WIND XX MPH MOON - NEW MOON - WAXING CRESCENT MOON - FIRST QUARTER MOON - WAXING GIBBOUS MOON - FULL MOON - WANING GIBBOUS MOON - LAST QUARTER MOON - WANING CRESCENT INDOOR HUMIDITY OK INDOOR HUMIDITY HIGH INDOOR HUMIDITY LOW NEW LOW TEMP. RECORD XX NEW HIGH TEMP. RECORD XX NEW WIND RECORD TODAY XX CURRENT RAINFALL X.XX/HR. RAIN EVENT STARTED XX HRS. AGO SENSOR BATTERIES LOW DISPLAY BATTERIES LOW SENSOR SIGNAL LOST...CHECK BATTERIES AND PLACEMENT CAUTION- HEAT INDEX IS XXX CAUTION- WIND CHILL IS XXX CALIBRATION DATA LOGGER FULL...CONNECT TO PC TO TRANSFER Rainfall HistoryRainfall DataDisplays rainfall recorded TODAY  since 12:00am,  if applicable.If there hasn’t been any rainfall today, the current week’s rainfall (Sunday to Saturday) is displayed, if applicable.If there hasn’t been any rainfall this week, the current month’s rainfall is displayed.TOTAL1”inchesmm25mmPLUIERAINJOURHOYTODAYLLUVIASEMANAHOYMESTOTAL1”inchesmm25mmPLUIERAINJOURHOYTODAYLLUVIASEMANAHOYMESTOTAL1”inchesmm25mmPLUIERAINJOURHOYTODAYLLUVIASEMANAHOYMESTODAY WEEK MONTH
16 17Problem Possible SolutionNo outdoor sensorreceptionno bars•  Relocate the display unit and/or the 5-in-1 sensor.  The units must be within 330 ft (100 m) of each other.•  Make sure both units are placed at least 3 feet  (90 cm) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc). •  Use standard alkaline batteries (or lithium batteries in sensor when temperature is below -4ºF/-20ºC). Do not use heavy duty or rechargeable batteries. NOTE: It may take up to 20 minutes for display unit and sensor to synchronize after batteries are replaced.•  Synchronize the units:1.  Bring both the sensor and display unit indoors and remove power adapter/batteries from each.2. Reinstall batteries in outdoor sensor. 3. Reinstall power adapter/batteries in display unit.4.  Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection. Outdoor  temperatureis ashing or   showing dashesFlashing of the outdoor temperature may be an indication of wireless interference.•  Make sure the A-B-C switch in the battery compartments of both the display unit and sensor are switched to the same letter. You may choose A, B or C; but both units must match to sync up. Sometimes changing to a different channel can help.Inaccurate forecast•  Weather Forecast icon predicts conditions for the next 12 to 24 hours, not current conditions.•  Has Learning Mode icon disappeared from the display unit? Learning Mode must complete before forecast and pressure will be accurate.•  Allow unit to run continuously for 33 days. Battery removal or resetting the display unit will restart Learning Mode. After 14 days, forecast should be fairly accurate, however Learning Mode calibrates for a total of 33 days.TroubleshootingProblem Possible SolutionInaccuratetemperature or  humidity•  Make sure both the display unit and 5-in-1 sensor are placed away from any heat sources or vents  (see page 11).•  Make sure both units are positioned away from moisture sources (see page 11). •  Make sure 5-in-1 sensor is mounted at least 5 ft off of  the ground.• Calibrate indoor and outdoor temperature and humidity (see page 19). No rainfall• Check to ensure the rain gauge stabilizer (plastic tab) has been removed from the bottom of the sensor (see page 7).• Clear debris, such as leaves, out of the rain collector funnel and debris screen.• Calibrate the Rain Gauge (see page 20).Inaccurate wind readings•  What is wind reading being compared to?  Pro weather stations are typically mounted at 30 ft high or more. Make sure to compare data using a sensor positioned at the same mounting height.•  Check location of the sensor. Ensure it’s mounted a minimum of 5 ft in the air with no obstructions around it (within several feet).• Ensure wind cups are spinning freely. If they hesitate or stop try lubricating with graphite powder or spray lubricant.Display screennot working•  Check that the batteries are installed correctly. Batteries may need to be replaced.•  Reset the display by pressing and holding the CLEAR RECORD / RESET button, located in the battery compartment of the display unit. Date and time will need to be entered after a reset.Troubleshooting
18 19If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call  (877) 221-1252 for assistance.Problem Possible SolutionCannot access dataonline or on the AcuRite mobile app• Verify that the status in the AcuRite Connect software on your PC indicates that data was uploaded OK.• Verify that you created an account or logged into an existing account at www.acu-link.com or in the AcuRite app, and that you input the display’s MAC ADDRESS as a part of the account setup.• Verify that the USB cable is securely connected to the display AND to the PC.• Verify the display is powered ON.• Verify the PC that the display is connected to is always powered ON.• Verify the PC that the display is connected to is always connected to the internet.• Verify that the display’s MAC ADDRESS is entered correctly in the AcuRite Connect software on your PC.• Verify that “Streaming” is enabled in the AcuRite Connect software on your PC.• Verify that the display’s MAC ADDRESS is correct in your www.acu-link.com and/or AcuRite mobile app account.• Follow on-screen troubleshooting steps in the AcuRite Connect software.AcuRite Connect data is different than the display’s data• Check that the USB cable is securely connected to the display AND to the PC’s USB port.• Restart the AcuRite Connect software.• Unplug the USB cable from the PC for 1 minute, and then plug the cable back in again.• USB port may be malfunctioning, try using another USB port.Troubleshooting Care & MaintenanceDisplay Unit CareClean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air.5-in-1 Sensor CareClean the SensorClean with a soft damp cloth. Do not use caustic cleaners or abrasives that will mar the polished surfaces of the rain collection funnel or the solar cell. Scratches will result in decreased performance and reliability.Insect Prevention Insects may cause obstructions and interrupt data by nesting in or on the 5-in-1 sensor. To limit this problem, spray sensor with a household insect repellent. Consult the insect repellent instructions prior to use.Snow & Freezing WeatherThe 5-in-1 sensor will not be damaged by freezing conditions. NOTE: If the rain collec-tor cup lls with snow and then melts, it will register as rain on the display unit.Clean the Rain Collector Cup Remove and empty  rain collector debris lter. The debris lter is located in the rain col-lector funnel. Remove from the top by gently squeezing and pulling out.Clean the Wind Vane & AnemometerRemove foreign matter from the outside of the sensor for free movement of the wind vane and anemometer. If needed, use a small amount of spray lubricant, clear silicone or graphite powder on the anemometer for improved movement.CalibrationThe indoor and outdoor temperature and humidity readings, and barometric pressure can be calibrated on the display unit to improve accuracy. Calibration can improve accuracy when sensor placement or environmental factors impact the data accuracy.1. To access calibration mode, press AND HOLD the “ ”, “   ”, and “  ” buttons simultaneously for at least 5 seconds.2. To adjust the currently selected (ashing) item, press and release the “ “ or “  “ buttons to calibrate the data value higher or lower from the actual reading.3. To save your adjustments, press and release the “   ” button to adjust the next preference. The “ ” icon will remain illuminated next to calibrated values.  The preference set order is as follows: OUTDOOR TEMPERATURE OUTDOOR HUMIDITY
20 21INDOOR TEMPERATURE INDOOR HUMIDITY BAROMETRIC PRESSURE  (must be set to MANUAL mode to calibrate)*  *To change from AUTO to MANUAL pressure mode and vice versa, press AND HOLD the “    ” button for 5-7 seconds. The display indicates the current pressure mode selected, “AUTO” or “MANUAL”. The “    ” icon will appear next to the barometric pressure to indicate that MANUAL mode has been activated. Press and HOLD the “     ” button for 5-7 seconds to return to AUTO mode. After 5-10 seconds of inactivity, the display will save the adjustments and exit calibration mode. Note: Calibrations will be erased if the display is reset or if batteries are removed and the power adapter is unplugged. Calibrate the Rain GaugeThe rain gauge on the 5-in-1 sensor can be calibrated to improve accuracy. Items Needed: 5-in-1 sensor, display unit, plastic cup, pin, screw driver1. First, ensure 5-in-1 sensor is perfectly level using built-in bubble level.2. Place display unit close so you can monitor it during calibration.3. Make a pin hole in the bottom of a plastic cup. Hold the cup over the rain gauge and ll it with exactly 1 cup (8oz) of water, allowing the water to drip into the rain gauge. You should hear the internal buckets tip and see water drain through the rain gauge.4. A few seconds after each bucket tip, the display unit displays rainfall in approximately 0.01” or more increments.5. The cup of water should take more than 20 minutes to empty; a quicker period will result in inaccurate calibration. Try to simulate a normal steady rainfall. When cup is empty of water, display unit should register 1.06”Tips• There should be nearly an equal number of water drops (about 25 water drops) between bucket tips. If not, adjust the calibration screws on the bottom of the 5-in-1 sensor until an equal number of water drops are tipping the buckets. Then, restart the calibration procedure.• If you don’t hear the buckets tipping and see water dripping alternately out of each drain, there may be an issue with the rain gauge or it’s adjustment. See Troubleshooting on page 18.AdjustmentIf the rain gauge doesn’t register close to 1.06”, make an EQUAL adjustment to the two calibration screws on the bottom of the 5-in-1 sensor. Turning screws clockwise increases rainfall; counter clockwise decreases rainfall.• To adjust the rainfall reading by 2% turn both screws 1/8  of a turn.  • To adjust the rainfall reading by 4% turn both screws 1/4 of a turn.  • To adjust the rainfall reading by 8% turn both screws 1/2 of a turn.Watch the video at www.acurite.com/5in1FCC InformationThis device complies with part 15 of FCC rules. Operation is subject to the following two conditions:1- This device may NOT cause harmful interference, and2- This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no  guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.This device complies with Industry Canada licence-exempt RSS standard(s).Operation is subject to the following two conditions:(1) This device may not cause interference, and(2) This device must accept any interference received, including interference that may cause undesired operation of the device.SpecicationsTEMPERATURE RANGE Outdoor: -40ºF to 158ºF; -40ºC to 70ºCIndoor: 32ºF to 122ºF; 0ºC to 50ºCHUMIDITY RANGE Outdoor: 1% to 99%Indoor: 1% to 99%WIND SPEED 0 to 99 mph; 0 to 159 kphWIND DIRECTION  INDICATORS  16 pointsRAINFALL 0 to 3937 in; 0 to 99999mmWIRELESS RANGE 330ft / 100m depending on home construction materialsOPERATING FREQUENCY 433 MHzPOWER Display: 4.5V AC, 250mA adapter             3 x AA alkaline batteries (optional)Sensor: 4 x AA alkaline or lithium batteriesDATA REPORTING Wind Speed: 18 second updates; Direction: 30 secondsOutdoor temperature & humidity: 36 second updatesIndoor temperature & humidity: 60 second updatesAcuRite Connect CSV Data Logging: 12 minute intervalsAcuRite Connect to AcuRite Software/App: 18 secondsDISPLAY UNIT MEMORY 512 kilobytes (not expandable)ACURITE CONNECT SYSTEM  REQUIREMENTS Windows 8.1 / 8 / 7; 1 GHz or faster processor; 1 GB (32-bit) or 2 GB (64-bit) of RAM; available USB portHigh speed internet is required for some advanced features of AcuRite Connect, such as the  AcuRite software and app.
22 23At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. We recommend that you visit us at  www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty benets.Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose. Chaney expressly disclaims all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaney’s products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, firm or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.For in-warranty claims:  Chaney Instrument Co.  |  965 Wells St.  |  Lake Geneva, WI 53147Limited One Year WarrantyPRODUCT REGISTRATIONRegister online  to receive 1 year  warranty protectionwww.AcuRite.comIMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE►Register a ProductCustomer SupportAcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways:  (877) 221-1252  info@chaney-inst.com24/7 support at www.AcuRite.com► Installation Videos  ► Register your Product► Instruction Manuals  ► Support User Forum► Replacement Parts  ► Submit Feedback & Ideas
©Chaney Instrument Co. All rights reserved.  AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy-rights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.Printed in China02064C INST 052215It’s More than Accurate, it’s AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to  Plan your day with condence™.www.AcuRite.comWeather StationsTemperature & HumidityWeather Alert RadioKitchen Thermometers & TimersClocks

Navigation menu