Chaney Instrument 278TX Digital Cooking Thermometer User Manual INST13 00278TX HR

Chaney Instrument Co. Digital Cooking Thermometer INST13 00278TX HR

User manual

Instruction ManualSAVE THIS MANUAL FOR FUTURE REFERENCE.Questions? Contact Customer Support at (877) 221-1252 or visit www.AcuRite.com.CONTENTSUnpacking Instructions ........... 2Package Contents .................. 2Product Registration ............... 2 ................. 2Setup .................................... 4Install or Replace Batteries...... 4Temperature Units .................. 4Food Preparation ................... 5 Using the Thermometer ........... 5Warning Messages ................ 8Troubleshooting ..................... 9Care & Maintenance .............10 ........................10FCC Information ...................10Customer Support ................. 11Warranty..............................11Digital Cooking Thermometermodels 00278 / 0028200278TX/ 00278RX
2 3Congratulations on your new AcuRite product. To ensure the best  possible product performance, please read this manual in its entirety  and retain it for future reference.Unpacking Instructions  Package Contents1. Thermometer display2. Temperature probe & cord3. Remote pager with belt clip 4. Instruction manualPRODUCT REGISTRATIONRegister online  to receive 1 year  warranty protectionwww.AcuRite.comIMPORTANT  Register a ProductThermometer DisplayRemote Pager1171223456781.  Meat Type Setup Indicator Select Beef, Veal, Chicken, Pork, Poultry,  Lamb, Fish, Custom or Boil. 2.  Meat Doneness Setup Indicator Select Rare, Medium or Well done;  temperatures based on USDA  recommended guidelines.3.  Target Temperature Setup  Indicator Select target temperature from 14ºF to 450ºF (-10°C to 232°C) 4. Backlight Button5.  Check Probe Indicator Indicates probe error, shown with  diagnostic code (see page 9).6.  Remaining Cook Time Estimates remaining time food needs to  cook during the cooking process7. Probe Plug-in 8.  Power ON/OFF Button9.  Meat Type Selection10. Meat Doneness Selection11. Target Temperature12. Alarm ON Indicator An audible alert will sound when target  temperature is reached. 13. Current Temperature Arrow icon indicates the direction the  temperature is trending and rate of  temperature change. 14. Rotary Dial for setup preferences. 15. SELECT button for setup preferences.16. ALARM Button Enables and mutes audio alert.17. Wired Temperature Probe1.  Low Battery Indicator Replace batteries when lit. 2.  Power ON/OFF button3.  Wireless Signal Indicator Lit when wireless connection is  established. See page 8.4. Alert Switch Select audio alert or silent vibrate  mode.5. Belt Clip9101112131415163 This product is not intended for use in cooking environments that exceed 45
4 5SETUPFood Preparationmay increase your risk of food-borne illness, especially if you have certain preparing meat and seafood. Please adhere to the recommended cooking temperatures.USDA Recommended GuidelinesProduct Minimum Internal Temperature & Rest TimeBeef, Pork, Veal & Lamb Steaks, chops, roasts145 °F (62.8 °C) and allow to rest for at least 3 minutesGround meats 160 °F (71.1 °C)All Poultry 165 °F (73.9 °C)Fish & Shellfish 145 °F (62.8 °C) For more information on food preparation safety, visit: http://www.fsis.usda.govUsing the Thermometer1. Before operating, plug the temperature probe into the thermometer display.3. Press the “ information can then be viewed.4. Press the “ ” button on the thermometer display to enable or disable the audio alert. With the function enabled, you will hear a beep each time a selection is made during setup and when target cooking temperatures are reached.5. Magnet-mountable design allows you to stick the thermometer on the oven door or fridge. 6. To use the Remote Pager, press the “ ” button on the pager.7. Slide the Alert switch, located on the side of the Remote Pager, to select audio alert or silent vibrate mode. Set to “  “ to enable audio alert. Set to “ “ to enable silent vibrate mode.Meat Type Setup2. To adjust the meat type, turn the rotary dial clockwise to move forward through the selections and counterclockwise to move backward through the selections   Install or Replace BatteriesAcuRite recommends high quality alkaline batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended. Select Degrees Fahrenheit or CelsiusTo select between degrees Fahrenheit (ºF) or Celsius (ºC) temperature units, slide the “ºF/ºC” switch, located in the battery compartment of the thermometer.PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.Remote Pager1.  Slide off the battery compartment cover, located on the bottom of the unit. 2.  Insert 2 x AAA batteries into the battery compartment. Follow the polarity (+/-) diagram in the battery compartment. 3.  Replace the battery cover. Thermometer Display1.  Slide off the battery compartment cover. 2.  Insert 3 x AA batteries into the battery compartment. Follow the polarity (+/-) diagram in the battery compartment. 3.  Replace the battery cover. OPERATION
6 7desired meat type is displayed. Meat Doneness Setupdisplay.2. To adjust the meat doneness, turn the rotary dial clockwise to move forward through the available meat doneness selections and counterclockwise to move backward through the selections.    doneness option is not available at all.3. As you move through the options, Target Temperature shown on the display will automatically update based on the selection.desired meat doneness is displayed. Target Temperature SetupAs noted above, Target Temperature shown on the display will automatically 2. To adjust Target Temperature, turn the rotary dial clockwise to increase the target temperature and counterclockwise to decrease the target temperature.3. As you make the adjustment, the Meat Type shown on the display will change to Custom.Current Temperature1. Insert the narrow end of the temperature probe into the thickest part of the food being cooked. Be sure the tip is not touching bone, gristle, the pan or inserted into the cavity of fowl.2. Hold steady for several seconds. 3. Current internal temperature of the meat will show on the display. 4. The arrow next to the current temperature reading indicates the direction temperature is trending and the rate of change.5. When the current temperature of the food reaches the target temperature the thermometer will beep.Be careful when touching the temperature probe and probe wire if it has been in or near hot food or surfaces.Remaining Cook TimeRemaining Cook Time estimates the amount of time food needs to cook. Cook time is determined by measuring and monitoring the cooking process, then applying a series of estimating methods. Remaining Cook Time is designed to work best with large oven roasted meats, but can also be used for other cooking applications.the Target Temperature.2. For optimum performance, probe should be inserted into the thickest part of the probe or power the unit off during cooking.3. Once cooking begins, the rising temperature automatically prompts the thermometer to calculate estimated cook time. The calculation may take 3-4 minutes or until internal food temperature reaches 105°F (41°C) to display; display shows dashes during the calculation process.4. When estimated Remaining Cook Time expires (or reaches 0:00), an audible beep sounds on the thermometer and remote pager (if in use).In most cases, Remaining Cook Time automatically adjusts for changes in the cooking process, however the following actions may impact its accuracy:If you feel Remaining Cook Time estimation has been compromised, reset the thermometer by pressing the “ TimerThe thermometer features a countdown timer. 2. To adjust the countdown time, turn the rotary dial clockwise to advance time and counterclockwise to decrease time. To save your adjustments, press and 4. When the timer reaches 1:00 remaining the thermometer/pager (if in use) will beep/vibrate.
8 95. When 0:00:00 is reached, thermometer/pager (if in use) beeps/vibrates  ” is pressed.BacklightPress the Backlight button to momentarily illuminate the display for 5 seconds. thermometer is powered OFF.Remote Pager SetupThe Remote Pager can receive alerts from the thermometer when the Target Temperature is reached or when the Timer reaches 0:00:00.1. Press  “ 2. Pager emits an audible chirp and the Wireless Signal indicator (green) 3. Wireless Signal indicator (green) remains lit when a good connection is established and maintained, indicating that the pager is ready for use.Remaining Cooking Time1. When the Timer reaches 1:00 of remaining cooking time, a brief audio alert will sound on the Remote Pager unit. If operating in Silent Mode, the unit will 2. When the Timer reaches 0:00:00 or the target temperature is reached the and a continuous series of 3 .5 second audio alerts will sound on the Remote Pager unit until the On/Off button is pressed. If operating in Silent Mode, the unit will vibrate for .5 seconds 3 times and repeat until the On/Off button is pressed.Power the Unit ON/OFFThe thermometer will automatically power off after several minutes of inactivity. Press  “”  to resume operation. To power off manually, press the  “ ” button.Warning Messagesthermometer batteries.Check ProbeDiagnostic Code Problem SolutionNo Probe cord is not connected to the thermometer.secure or reconnect cord.SCProbe cord is not functioning properly. Cord may have been damaged or exposed to extreme heat.Check the wire and connection for damage or excessive heat. Replace cord.Remote PagerLights SolutionRed & Green Blinking Red Solid Replace the batteries.TroubleshootingProblem Possible SolutionInaccuratetemperature UÊÊheavy duty or rechargeable batteries.Check Probe Display screennot workingmay need to be replaced.Pager lights are blinking The units must be within 200 ft (60 m) of each other.(.9 m) away from electronics that may interfere microwaves, computers, etc). If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call  (877) 221-1252 for assistance.
10 11At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. We recommend that you visit us at  www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaneroducts, the purchaser assumes all liability for the consequences arising authorized to assume for Chaney any other liability in connection corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty rights which vary from state to state.For in-warranty claims:  Chaney Instrument Co.  965 Wells St.,  Lake Geneva, WI 53147Limited One Year WarrantyPRODUCT REGISTRATIONRegister online  to receive 1 year  warranty protectionwww.AcuRite.comIMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICERegister a ProductCustomer SupportAcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways: (877) 221-1252  info@chaney-inst.com24/7 support at www.AcuRite.comInstallation Videos  Register your ProductInstruction Manuals  Support User ForumReplacement Parts  Submit Feedback & IdeasCare & MaintenanceStore in a dry location at room temperature. Clean thermometer with a soft, damp cloth. Temperature probe should be wiped clean with warm water immediately after direct contact with foods. DO NOT place display unit on or near hot surfaces. DO NOT heat beyond thermometertemperature capacity. DO NOT use in oven. DO NOT wash in dishwasher. DO NOT immerse in water or use caustic cleaners or abrasives. DO NOT allow any part of the temperature probe or probe wire to come into probe cord. DO NOT lift or move the thermometer by the temperature probe wire connection.TEMPERATURE RANGE -40ºF to 450ºF; -40ºC to 232ºC Probe cord heat resistant up to 700ºF (371ºC)TIMER RANGE 9 hours, 59 minutes, 59 secondsREMAINING COOK TIME RANGE 9 hours, 59 minutesWIRELESS RANGE 200 ft / 60 m depending on home construction materialsPOWER Thermometer: 3 x AA alkaline batteries Pager: 2 x AAA alkaline batteriesFCC InformationThis device complies with part 15 of FCC rules. Operation is subject to the following two conditions:1- This device may NOT cause harmful interference, and2- This device must accept any interference received, including interference that may cause undesired operation.userthority to operate the equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equip-ment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Reorient or relocate the receiving antenna.rease the separation between the equipment and the receiver.the equipment into an outlet on a circuit different from that to which the receiver is connected.the dealer or an experienced radio/TV technician for help.This device complies with Industry Canada licence-exempt RSS standard(s).Operation is subject to the following two conditions:(1) This device may not cause interference, and(2) This device must accept any interference received, including interference that may cause undesired operation of the device.The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance. Le dispositif rencontre l'exemption des limites courantes d'évaluation dans la section 2.5 de RSS 102 et la conformité à l'exposition de RSS-102 rf, utilisateurs peut obtenir l'information canadienne sur l'exposition et la conformité de rf.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
©Chaney Instrument Co. All rights reserved.  AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy-rights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.Printed in China00278 INST 081313It’s more than accurate, it’s AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to  ™.www.AcuRite.comWeather StationsTemperature & HumidityWeather Alert Radio Thermometers & TimersClocks

Navigation menu