Users Manual Rev 2

        Peoplefinder II On-Site Communications System 7M303-1 Rev A3  User Manual  Firmware Version 307D90                    CalAmp Corp 1401 N. Rice Avenue Oxnard, CA  93030 PH: 805-987-9000 Fax: 805-987-8359 Email: sales@calamp.com
«ProductName»    User Manual 7M303-1 Rev A2  Page  2 Table Of Contents 1 Installation ...................................................................................................................................................... 5 1.1 Environment ........................................................................................................................................... 5 1.2 Licensing ................................................................................................................................................ 5 1.3 Radio Communication Interference ........................................................................................................ 5 1.4 Locating the Peoplefinder II ........................................................................................................................... 5 1.5 Unit Setup ............................................................................................................................................... 5 2 Local Operation .............................................................................................................................................. 6 2.1 Overview ................................................................................................................................................ 6 2.2 Keypad .................................................................................................................................................... 7 2.3 External Keyboard .................................................................................................................................. 7 2.4 Display .................................................................................................................................................... 8 2.5 Sending a page ........................................................................................................................................ 8 2.6 Group Page ............................................................................................................................................. 9 2.7 Tone Paging to Alphanumeric or Numeric Pagers ................................................................................. 9 2.8 2-way Data Communication ................................................................................................................... 9 2.9 2-way voice communications ................................................................................................................. 9 2.10 Alarm Pages ............................................................................................................................................ 9 3 Two-way Radio Operation ........................................................................................................................... 10 3.1 Sending Pages from the Two-Way Radio ............................................................................................. 10 3.2 Unit Setup ............................................................................................................................................. 11 3.3 Configuration Mode ............................................................................................................................. 13 4 Program Mode .............................................................................................................................................. 16 4.1 Assign Pager ......................................................................................................................................... 16 4.2 Assigning a Group ................................................................................................................................ 17 4.3 Sending Test Pages ............................................................................................................................... 19 4.4 Alarm Pages .......................................................................................................................................... 19 5 Diagnostics ................................................................................................................................................... 20 5.1 Built-in Diagnostics .............................................................................................................................. 20 5.2 Remote Diagnostics .............................................................................................................................. 20 6 Serial Port Protocols ..................................................................................................................................... 21 6.1 TAP ...................................................................................................................................................... 21 6.2 TAP Protocol Issues ............................................................................................................................. 23 6.3 Sending Multiple-Line Pages ............................................................................................................... 24 6.4 Computing the Checksum..................................................................................................................... 24 6.5 COMP1 ................................................................................................................................................. 24 6.6 COMP2 ................................................................................................................................................. 25
«ProductName»    User Manual 7M303-1 Rev A2  Page  3 6.7 ASCII control characters ...................................................................................................................... 25 7 Database Transfer ......................................................................................................................................... 26 7.1 Database Format ................................................................................................................................... 26 7.2 Retrieving the Database ........................................................................................................................ 27 7.3 Restoring/Uploading the Retrieved Database ....................................................................................... 29 8 Firmware Updating ....................................................................................................................................... 32 9 External Connectors ..................................................................................................................................... 33 9.1 External Transceiver ............................................................................................................................. 33 9.2 Keyboard Connector ............................................................................................................................. 33 9.3 Serial I/O Ports ..................................................................................................................................... 33 9.4 Auxiliary/Alarm Connector .................................................................................................................. 34 10 Specifications ........................................................................................................................................... 35 11 Alignment ................................................................................................................................................. 37 11.1 Adjustments .......................................................................................................................................... 37 11.2 Alignment Procedure ............................................................................................................................ 37 12 Appendix A - Frequency Coordinators ..................................................................................................... 39 12.1 For frequencies designated with an "IW" in Section 90.35 of the Commission's rules: ....................... 39 12.2 For frequencies designated with an "IP" in Section 90.35 of the Commission's rules: ........................ 39 12.3 For frequencies designated with an "LR" in Section 90.35 of the Commission's rules: ....................... 39 12.4 For all other frequencies, applicants may use any of the coordinators listed above or one of the following: ......................................................................................................................................................... 39 13 Appendix C - "Voice Prompt" Technical Details ..................................................................................... 41  Copyright Notice The Peoplefinder II contains copyrighted Software stored in its internal EPROM and FLASH memories.  Vytek retains all rights to the Software, including the exclusive right to copy or reproduce in any form the software in this product.  The Software (which includes the data in the EPROM and FLASH memories) may not be copied without the expressed written consent of Vytek.  Purchasing this product does not grant, either directly or by implication, the buyer any license to use the Software for any purpose other than for the normal operation of the purchased product.
«ProductName»    User Manual 7M303-1 Rev A2  Page  4 RF Exposure Compliance Requirements   The Peoplefinder II is intended for use in the Irrigation Monitoring and Control markets. The Peoplefinder II must be professionally installed using a maximum of 2.5dBi gain antenna and must ensure a minimum separation distance listed in the table below between the radiating structure and any person.      Maximum Antenna Gain   2.5 dBi  Min Safety Distance (2W + 20% with 2.5dBi)   33.8 cm    It is the responsibility of the user to guarantee compliance with the FCC MPE regulations when operating this device in a way other than described above.  The installer of this equipment must ensure the antenna is located or pointed such that it does not emit an RF field in excess of Health Canada limits for the general population.  Peoplefinder II uses a low power radio frequency transmitter. The concentrated energy from an antenna may pose a health hazard. People should not be in front of the antenna when the transmitter is operating.  Recommended safety guidelines for the human exposure to radio frequency electromagnetic energy are contained in the Canadian Safety Code 6 (available from Health Canada), the Federal Communications Commission (FCC) Bulletin 65 and the Council of the European Union’s Recommendation of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC).
«ProductName»    User Manual 7M303-1 Rev A2  Page  5 1  Installation 1.1  Environment The Peoplefinder II is designed for an indoor office environment.  Ambient air temperature should be between -10 and +40C, and relative humidity in the 20-80% range.  Operation outside of this range may cause damage to the unit.  1.2  Licensing This product operates in the commercial two-way radio communications band.  A license to operate on a particular frequency must be obtained from the FCC. Use form 600 to apply for a license to operate this unit in your area.  Operation of this product must be in compliance with the applicable FCC rules and regulations.  In most cases, the FCC Rules and Regulations are covered in Title 47 of the CFR, part 90.  Form 600 is available at the FCC WEB site: http://www.fcc.gov/formpage.html.  See appendix A for a list of frequency coordinating agencies. This product is Certified for use under FCC Part 90.  Internal circuitry may not be modified. Modification of circuitry within this unit may void your authority to operate the equipment. 1.3  Radio Communication Interference The Peoplefinder II generates and uses high-frequency radio energy that can cause interference if not installed in accordance to the user manual and using sound radio system engineering practice.  For best results, it is recommended that a qualified radio service technician install and configure the Peoplefinder II.  The Peoplefinder IIhas been tested and found to comply with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules and Regulations.  Operation of this device in a residential area is likely to cause interference in which case the user must, at his own expense, be required to take whatever measures may be required to correct the interference.  1.4  Locating the Peoplefinder II The Peoplefinder II is designed to sit on a desktop.  Although this is a good location for ease of operation, it is usually not the best place to locate the antenna.  For most installations, it is recommended that the antenna be located away from the unit, and high enough to provide good coverage.  "Base Station" type antennas will provide much better coverage than will the "rubber duck" type antennas.  This is particularly true if an external keyboard is to be used, since many keyboards malfunction in the presence of strong RF fields. The LCD's contrast may be adjusted through a small hole in the rear of the unit. If the LCD is difficult to read adjust its contrast with a small flat-bladed screwdriver.  1.5  Unit Setup a) Connect the antenna or antenna cable to the BNC jack on the rear of the unit.  b) If you are using the Peoplefinder II with a computer system, connect the computer's RS-232 port to the lower serial port on the rear of the unit. c) If you are using an external keyboard, connect it to the PS-2 keyboard jack at the rear of the unit.  d) Connect the DC power supply to the Peoplefinder II. It connects to the large DIN connector on the rear.  Plug the external DC supply into an AC wall socket.  Turn the power to the unit ON.  e) Configure the unit if necessary using the Configuration Mode.
«ProductName»    User Manual 7M303-1 Rev A2  Page  6 2  Local Operation 2.1  Overview The Peoplefinder II is a desktop system that provides paging and wireless two-way communications.  With an Intel 32 bit processor at its core, and 4 megabytes of FLASH memory, the Peoplefinder II can handle the wireless communications needs of the small office or a large plant.   Peoplefinder II features:  Stand-alone operation with built-in keypad and LCD display.   Two built-in RS-232 serial ports for advanced paging applications.  Internal two-way radio for monitoring the channel and two-way voice communication.   POCSAG paging encoder at 512, 1200, and 2400 baud  Data Mode 2FSK 9600 baud  Optional two-tone and group-tone paging   1000 pager database  Group paging  8 external alarm inputs for automatic generation of pre-programmed pages.   Pages may be initiated from DTMF equipped two-way radios.  Built-in speaker and microphone, with provisions for external connections.  May optionally be programmed and operated using an external keyboard  Note: Peoplefinder II with FCC ID “J26-PC-UC-2” and IC ID “773B-NBBS01” does not have a functional phone interface.   The Peoplefinder II operates in one of two basic modes.  They are the Page Mode and the Program Mode. The Page Mode is used to send digital pages to a selected pager or group of pagers.  It may also be used to communicate with a two-way radio up to 9600bps.  For the Peoplefinder II to send pages to a pager, it must first be programmed with the pager's CAP code.  This is done once, using the Program Mode.  The Program Mode is used to set up the individual pager's information, group information, automatic paging information, and some system-level features.  Although the operator may send pages using the built-in keypad or an external keyboard, pages may also be generated in a variety of other ways.  Pages may be initiated through the two RS-232 serial ports on the rear of the unit.  The Peoplefinder II may also be configured to automatically generate a page, based upon an electrical input to special input pins on the rear of the unit.   The Peoplefinder II is one of the most versatile paging devices on the market today! The Peoplefinder II has an internal database, which stores the CAP code for every pager in your system.  The CAP code is the special 7 digit code that identifies an individual pager or paging receiver device.  To make paging simpler, you need only configure the CAP codes once by assigning it an easy-to-remember number.  For instance, you may have 3 pagers with the following CAP codes: 1924589, 0029111, 0935199.  You can program them into the database as pager numbers 1, 2, and 3 as follows: Pager CAP Code  Pager Number 1924589  1 0029111  2 0935199  3 Now, when it comes time to page pager 2, you will only have to enter the digit 2, rather that the whole CAP code.  Other parameters that must be entered into the database for each pager are the pager type (tone, numeric, alpha-numeric), baud rate (512, 1200, 2400) active or inactive status, and which groups it belongs to (if any).
«ProductName»    User Manual 7M303-1 Rev A2  Page  7 To facilitate sending pages to a large number of different pagers, groups of pagers may be set up in the Peoplefinder II.  A group is first assigned a number, and the members of the group are programmed into the group pager database.  Once a group is set up, a page may be sent to all the members of the group simply by sending the page to the given group.  2.2  Keypad The built-in keypad is used to program the unit, and to manually enter pages. Its keys have the following functions: Key Primary Use Secondary Use 0 thru 9 Entering numbers Selecting a sub-menu F1 Send a page after it is entered Select options from the sub-menus F2 Monitor the channel  Back up to previous menu item F3 Talk to a two-way radio Monitor the channel if it is busy F4 Send a tone-only page to a numeric or alphanumeric pager  DEL Correct an incorrect entry  - (Program) Used as a dash (-) when entering a message. Enters the programming mode and exits menus  Up/down arrows scroll through various options on the display.  VOL+/- Adjust the local speaker volume   The Peoplefinder II has a keypad buffer that allows a user to type faster than the prompts on the display come up.  Keystrokes will not be lost, and efficient data entry is possible by operators skilled in the operation of the Peoplefinder II.   2.3  External Keyboard An external keyboard with a PS-2 connector may optionally be used if desired. When the external keyboard is connected, the unit's built-in keypad continues to operate normally.  The external keyboard's keys function the same way as do the unit's keypad in most cases.  Additional features are:  The alphabetic keys may be used when entering pages to alphanumeric pagers.    The ESC key is mapped to the keypad's "-" key.  The ENTER key is mapped to the keypad's F1 key.  The NUM LOCK key is enabled by default, permitting the operator to use the keyboard's numeric keypad for more efficient entry of numeric data.  Note that the keypad's "." key is mapped to the DEL key.  Pressing CTRL and the Windows "MENU" key simultaneously, or pressing the ALT and TAB keys simultaneously enters the Setup Mode.  “Low state” alarm pages may be initiated by pressing a number key between 1 and 8 while holding the CTRL key.  Pressing the SHIFT key at the same time will select the “High State” alarm pages. Only keyboards that are FULLY compliant with the standard keyboard communication protocol will work properly with the Peoplefinder II.  It has been found that some keyboards do not properly implement the "retry" protocol and therefore do not work well when the Peoplefinder II is busy processing pages from several sources. If an external keyboard does not work properly with the Peoplefinder II, try using another brand of keyboard.
«ProductName»    User Manual 7M303-1 Rev A2  Page  8 IMPORTANT NOTE:   Some keyboards are extremely sensitive to the high RF fields present when an antenna is connected directly to the rear of the Peoplefinder II .  The keyboard may stop functioning properly after the Peoplefinder II transmitter is turned on.  If this situation occurs, it is recommended that the antenna be mounted at least several feet from the Peoplefinder II or that a different brand of keyboard be used. 2.4  Display There is a two-line, twenty-character LCD display on the Peoplefinder II. The three LEDs on the top right side of the unit indicate the state of the transmitter, whether the channel is busy, and the programming mode.  2.5  Sending a page The Peoplefinder II is ready to send a page when the LCD display shows:  This means the Peoplefinder II is waiting for you to enter the pager number to which you wish to send a page.  Using the keypad or an external keyboard, enter the number (not the CAP code) of the pager you wish to page.  Once you enter the pager number, press the F1 key.  There are three standard types of pagers supported by the Peoplefinder II. They are: tone-only, numeric and alpha-numeric.  An option is available which supports two-tone pagers as well.  Depending upon what type of pager you are sending the page to, one of the following sequences will take place: 1. POCSAG tone-only pagers If the pager is a tone-only type, it does not have a display. A page sent to it will cause it to beep.   When a page is sent to it, the display will show TONE PAGER while it is sending the page over-the-air to the pager.  This will take about one second, after which it will display PAGE ACCEPTED for a couple seconds, and then return back to the PAGER NO= prompt. 2. Numeric and alpha-numeric pagers If the pager is designated as a Numeric pager or an Alphanumeric pager in the Peoplefinder II database, then the LCD display will show NUMERIC PAGER or ALPHA PAGER for one second, and then the LCD display will show ENTER MESSAGE.  The user enters the message using the keypad into line 2 of the display.  If the message is longer than the length of the display, the display will automatically scroll down to the next line as the message is entered.  Pressing the DEL key deletes the previous character entered.  Once the data is entered, press the F1 key to send the page.  The display will show PAGE ACCEPTED for a couple seconds and then the display will return back to the PAGER NO= prompt. Note that:  Only messages with numbers may be sent when using the built-in keypad.    Alphanumeric messages may be sent to alphanumeric pagers when using an external keyboard or the computer interface.  The POCSAG characters "[", "]", "-", "space" and "U" may be sent to numeric pagers when using the external keyboard, mobile radio or the computer interface. 3. Two-tone pagers Two tone pagers accept a sequence of two tones.  The CAPCODE is a number between 0 and 999.  A large number of standard tone plans are supported by the Peoplefinder II.  Pagers with non-standard tone frequencies PAGER NO  =
«ProductName»    User Manual 7M303-1 Rev A2  Page  9 may be programmed via the database upload command.  After the paging tones are sent, an alert sound or a voice message from the console may optionally be sent to the pager.   Typically it takes a second or more to send a page to a pager. If the page is intended for a group of pagers, it may take longer.  A group consisting of 10 pagers may take 5-10 seconds to transmit, and a group of 100 pagers may take 50-100 seconds to transmit.  2.6  Group Page The Peoplefinder II can send a page to a group of pager numbers through the entry of a single group number.  The pager numbers that are members of the group must have been previously assigned using the Assign Group configuration menu.  When sending a group page, the Peoplefinder II sequentially sends the page to each pager in the group.  The procedure for sending a group page is the same as for the individual page described in the above procedure.  Group pages generally take longer to send out, so you may find the Peoplefinder II will take a bit longer to return to the PAGER NO= prompt when a group page is sent.   2.7  Tone Paging to Alphanumeric or Numeric Pagers Some pagers can receive tone or numeric pages.  If you wish to send a tone page (make it beep) to a POCSAG pager that is set-up for numeric or alpha paging, you can press the F4 (Tone) key when entering the page instead of the F1 (Enter) key.  Pressing the F4 key after entering the pager number will force the Peoplefinder II to send a tone page to the pager. 2.8  2-way Data Communication The Peoplefinder II can be configured as a 2 way 9600bps modem. 2.9  2-way voice communications The Peoplefinder II can communicate with portable and mobile two-way radios.  The Peoplefinder II has a privacy feature called Continuous Tone Coded Squelch System (CTCSS). CTCSS blocks the reception of signals (or noise) that are not encoded with certain preset low frequency tones. You will only hear signals at the Peoplefinder II that have the correct CTCSS tone encoded on them.  This means that the radio channel may be in use by someone else, and you will not hear anything come out the speaker because the CTCSS decoder has muted it.  To disable the CTCSS decoder momentarily in order to monitor all of the communications on the channel, press the F2 key on the built-in keypad.  To talk on the radio channel, press and hold down the F3 key on the built-in keypad.  If the channel is not in use, the Peoplefinder II will turn the transmitter on and display TALK on the LCD.  Your voice will be transmitted out over the air.  The microphone is located on the front of the unit, so speak clearly towards it in a normal voice.  2.10  Alarm Pages The Peoplefinder II has 8 alarm inputs located at the rear of the unit.  The unit may be configured to send a page when an alarm input changes states.  Different messages may be sent for high or low going changes of state.   For convenience sending pre-programmed messages, alarm pages may also be initiated from the external keyboard.  Low change alarm messages may be generated by pressing CTRL and a number key "n" simultaneously, where "n" is the desired alarm number.  High change alarm messages may be generated by pressing CTRL, SHIFT and the number key simultaneously. If no message has been programmed for a specific alarm page state, then no page will be sent.  This feature may be used to only send pages for a specific state transition, but not for the opposite state transition.
«ProductName»    User Manual 7M303-1 Rev A2  Page  10 3  Two-way Radio Operation  The Peoplefinder II has a built-in radio transceiver enabling it to communicate with other two-way radios and to receive over-the-air commands to generate pages.   To remotely control the Peoplefinder II with a two-way radio, the two-way radio must be equipped with a DTMF encoder.  All commands sent to the Peoplefinder II are entered via the DTMF keypad, and in most cases, the commands are similar to the ones used locally on the Peoplefinder II's built-in keypad.  During two-way radio operations, the Peoplefinder II will not transmit pages.  Any pages entered by the front panel, external keyboard or computer ports will be queued and sent later, when the radio is idle. 3.1  Sending Pages from the Two-Way Radio This section describes how to send a page with the Peoplefinder II using a DTMF keypad-equipped two-way radio.   The Peoplefinder II and the two-way radio must have previously been configured to communicate on the same channel, and utilize the same CTCSS tones.   To send a page to a pager from the two-way radio, you must: 1. Send *9 to alert the Peoplefinder II that you intend to send a page.  2. If desired, optionally listen to the receiver for the "Enter Pager Number" prompt, which is a sequence of three beeps.  A series of alternating high and low beeps indicates an error in the command sequence or a timeout occurred. If voice prompts have been enabled, then a voice message will be heard instead of the beeps. 3. Enter the digits of the pager number you wish to page.  If the pager's number is less than three digits in length, then press the *key to terminate the pager's number.  Note that the *key is not used to terminate three digit pager numbers. 4. If desired, optionally listen to the receiver for a low / high beep sequence, which signifies that the pager number was accepted.  A series of alternating high and low beeps indicates an error in the pager number or a timeout occurred. If voice prompts have been enabled, then a voice message will be heard instead of the beeps. 5. Enter the numeric digits you wish to send to the pager.  Do not enter any digits if you only wish to "beep" the pager.  Note that the following DTMF keys have special meanings:  DTMF Key Pager Character Comments * - Hyphen character # {none} Send the page A  Space character B ] Right bracket C [ Left bracket D U Urgency indicator 6. Press the # key to send the page. To send a new message to the same pager again, you may: 1. Type *0 to alert the Peoplefinder II that you intend to send a page to the same pager number as before.  2. Continue from step 4 of the instructions above to input the new message to be sent.
«ProductName»    User Manual 7M303-1 Rev A2  Page  11 3.2  Unit Setup The Peoplefinder II supports numerous functions and operating modes.  These are programmed via a series of menus.  The following table lists configuration parameters and menus within the Peoplefinder II unit that the user may wish to modify.  Operating parameters are stored in non-volatile memory, and will not need to be reconfigured during the life of the product unless the user wishes to change them.  The default settings are shown in BOLD.  PEOPLEFINDER II COMMAND MENU STRUCTURE  System Configuration (Key 1 held down during power-up, or CTRL-MENU or ALT-TAB from an external keyboard) PASSWORD = Contact Distributor  1 SERIAL PORT #1      1 SERIAL DATA BITS     7 DATA BITS        8 DATA BITS       2 SERIAL PORT RATE           1 - 300 BAUD           2 - 600 BAUD           3 - 1200 BAUD           4 - 2400 BAUD           5 - 4800 BAUD           6 - 9600 BAUD                 7 - 19200 BAUD   3 SERIAL STOP BITS     1 STOP BIT              2 STOP BITS       4 SERIAL PARITY     EVEN PARITY              ODD PARITY              NO PARITY   5 FLOW CONTROL     NO FLOW CONTROL     HARDWARE CONTROL  6 SERIAL PROTOCOL           1 TAP           2 COMP1           3 COMP2   7 TAP TIMEOUT         {30 Seconds default}   8 COMP TIMEOUT     {60 Seconds default}   9 MANUAL TIMEOUT     {90 Seconds default}  2 SERIAL PORT #2      1 SERIAL DATA BITS     7 DATA BITS        8 DATA BITS 2 SERIAL PORT RATE           1 - 300 BAUD           2 - 600 BAUD           3 - 1200 BAUD           4 - 2400 BAUD           5 - 4800 BAUD           6 - 9600 BAUD                 7 - 19200 BAUD       3 SERIAL STOP BITS     1 STOP BIT              2 STOP BITS       4 SERIAL PARITY     EVEN PARITY              ODD PARITY              NO PARITY   5 FLOW CONTROL     NO FLOW CONTROL     HARDWARE CONTROL  6 SERIAL PROTOCOL           1 TAP           2 COMP1           3 COMP2   7 TAP TIMEOUT         {30 Seconds default}   8 COMP TIMEOUT     {60 Seconds default}   9 MANUAL TIMEOUT     {90 Seconds default}  3 MODE SELECTION   1 SPEAKER ENABLE     ENABLE     DISABLE     2 BUSY CH LOCKOUT     ENABLE     DISABLE     3 REMOTE PAGING     ENABLE     DISABLE     4 CALL FORWARDING     ENABLE     DISABLE     5 AUTOPATCH TIMER     0 = PATCH DISABLED     DEFAULT = 10 MINUTES     6 VOICE PROMPTS     ENABLE     DISABLE     7 WARMUP SIGNAL     ENABLE     DISABLE    8 RINGS TO ANSWER     0= ANSWER IMMEDIATELY     1= DEFAULT     9 NUMBER DONE DELAY     {5 Seconds default}  4 TRANSCEIVER   1 TX SETUP           1 TX FREQUENCY       { 464.5 MHz}     2 TX SIGNALING                1 (CARRIER ONLY)                2 CTCSS           3 TX BANDWIDTH       NARROW BAND                   WIDE BAND     4 TX DATA DELAY (MS)       { 20 mS default} 2 RX SETUP    1 RX FREQUENCY     { 464.5 MHz}   2 RX SIGNALING     1 (CARRIER ONLY)     2 CTCSS   3 SHIFT CPU CLOCK?     DISABLED     ENABLED 3 INVERT CARRIER DETECT     YES     NO   4 INVERT TRANSMIT DATA     YES     NO   5 TX TYPE     NO TYPE SELECTED      VHF (MODEL 204)     UHF     VHF (MODEL 3464)     UHF (MODEL 3412-X)  6 TX/RX SWITCH TIME (MS)     DEFAULT = 50 MS  5 CW CALL SIGN   {DEFAULT = NONE}    6 DIAGNOSTICS MODE   {See below for details}
«ProductName»      User Manual  7M303-1 Rev A1  Page 12 Reset FLASH Memory (Key 8 held down during power up)  RESET FLASH? PASSWORD = 42983 RESET FLASH?  NO   YES   Program Mode (Key "-" held down during normal operation) PASSWORD = 7531  1 ASSIGN PAGER       PAGER NO =       ACTIVE?     YES     NO    TYPE =      POCSAG 512           POCSAG 1200           POCSAG 2400     TWO TONE   FUNC =           TONE           NUMERIC           ALPHA     TONE ONLY     TONE+ALERT     TONE+VOICE     TONE+PATCH ALERT OR VOICE DURATION    {0 TO 31 SEC}   0 = 1/2 SECOND SELECT TONE GROUP CAPCODE = DIAGONAL TONE SELECT   FIRST TONE   SECOND TONE   GROUP TONE SAVE CHANGES?   YES  NO  2 ASSIGN GROUP       SELECT GROUP    ASSIGN PAGER NUMBER   SELECT GROUP   FUNC     TONE           NUMERIC           ALPHA        ENTER MEMBER NUMBER       ENTER PAGER NUMBER   3 TEST PAGE   PAGING PAGER 0  4 ALARM PAGES       ALARM NUMBER =       ALARM  x  PAGER       ALARM LOW MESSAGE       ALARM HIGH MESSAGE  5 AUTODIAL MEMORY AUTODIAL MEMORY = ENTER PHONE NUMBER   {DEFAULT = NONE}  Diagnostics Mode (Menu item 6 from the System Configuration Mode)  F1 TOGGLE PHONE CONNECTION   DISCONNECTED   CONNECTED  F2 TOGGLE RADIO CONNECTION   DISCONNECTED   RECEIVE MODE   TRANSMIT MODE  F3 CONNECT MICROPHONE   DISCONNECTED    CONNECTED F4 TOGGLE SPEAKER CONNECTION   DISCONNECTED   CONNECTED  1  PAGER BIT TEST   512 BAUD   1200 BAUD   2400 BAUD  2  SOUND TESTS   {Press number, function or arrow keys}  3  DTMF TESTS   (UP ARROW key selects modes)   ENCODER TEST MODE   DECODER TEST MODE   ENCODER BEEP MODE   ENCODER LOW TONE   ENCODER HIGH TONE  4  DAC RAMP TEST 5 LCD TESTS 6 KEYPAD & KEYBOARD TESTS 7 ALARM INPUTS 8 FIRMWARE VER
«ProductName»      User Manual      7M303-1 Rev A2  Page 13 3.3  Configuration Mode  Configuration Mode is for qualified maintenance personnel only. The System Configuration Mode is entered by holding the 1 key down on the front panel while the power is turned on, by pressing the CTRL and MENU keys, or by pressing the ALT and TAB keys simultaneously from the external keyboard. The Peoplefinder II will prompt the user for a password before entering the configuration programming mode.  Press the arrow keys to cycle through the configuration parameters.  The Menu number in the table above lists the location within the Peoplefinder II programming menus that the particular parameters may be found.  To change any of the parameters that require a numeric entry, press the number key to enter the value and then press the F1 key. In the case of values that will scroll, press any number key to scroll through the available selections.   Press the - key to exit from sub-menus to the upper level menus. To exit the configuration mode, press the - key.  Note that values are not permanently stored until the Configuration Mode is exited by pressing the - key.  If the unit is turned off, or power is lost before the - key is entered, changes to the configuration are not stored. 3.3.1  Serial Port Setup Each of the two serial ports may be configured independently.  The table above lists the parameters that may be programmed.  The serial ports are located at the rear of the unit and are labeled PORT 1 and PORT 2.   Timeout parameters for the various protocols are given in seconds.  Set the timeout to 0 if no timeout is desired. 3.3.2  Speaker Enable If this mode is disabled, then the speaker is muted at all times except in the Diagnostics Mode.  This may be used if the Peoplefinder II is in a location where sounds from the speaker are not desirable. 3.3.3  Busy Channel Lockout If this mode is enabled, then the Peoplefinder II will not transmit if the channel is busy.  This may be desirable in order to avoid interfering with other users on the channel.  This mode should be disabled if there is so much activity on the channel that the pages are not sent out in a timely manner. 3.3.4  Remote Paging If this mode is enabled, then remote users are permitted to call the Peoplefinder II via a telephone line and to generate pages to be transmitted.  Note: Telephone is no longer supported. 3.3.5  Call Forwarding If this mode is enabled, then remote users are permitted to call the Peoplefinder II via a telephone line and to request a phone autopatch with two-way-radio users.  Note: Telephone is no longer supported. 3.3.6  Autopatch Timer The autopatch timer establishes the length of time the Peoplefinder II waits before hanging up the autopatch automatically.  This is needed in case the two-way-radio user's batteries fail or he goes out of range Enter the number of minutes the autopatch may be operated before the disconnect warning tones are sent. The DEL key may be used to delete digits.  Press the "-" key to exit the menu.  Note that autopatch operation may be disabled by setting the Autopatch Timer value to 0.
«ProductName»      User Manual      7M303-1 Rev A2  Page 14 3.3.7  Voice Prompts This mode selects whether beeps or voice prompts are used to confirm radio operations with the Peoplefinder II. The language of the voice prompts is determined by which firmware file has been loaded. If you are interested in a language other than English, contact your distributor for availability. 3.3.8  Warmup Signal If this mode is enabled, then a special "warmup" signal is transmitted for a brief period of time at the beginning of each page.  This is required for more reliable operation by some pagers. 3.3.9  Transceiver Setup The Peoplefinder II either contains a two-way transceiver or works with an external transceiver.  In either case, the factory has programmed the correct Transmitter Type, Carrier Detect inversion, Transmit Data inversion, and the TX Bandwidth.  The user should not change these settings or improper operation will result. 3.3.10  TX/RX Switch Time This parameter is used by the autopatch to determine the sampling time to listen for the mobile radio user when transmitting the phone user's voice. If it is set too small, the mobile radio user will not be able to interrupt the transmitter when in the autopatch mode.  If it is set too large, then the transmitter's dropout time will be excessive. 3.3.11  Transmit and Receive Frequencies Enter the desired transmit or receive operating frequency using the number keys.  The decimal point will automatically be entered.  Use the DEL key to delete any correct entries.  Press the F1 or "-" key to accept the new frequency. 3.3.12  Transmit and Receive Signaling Carrier Squelch operation may be desirable if there are no other users on the channel and there is no interference.  In this mode, the two-way-radio users will be able to hear the paging signals transmitted by the Peoplefinder II.  To enable this mode, press 1 to select (CARRIER ONLY).  Press the "-" key to exit the menu. If there are other users sharing the channel, if there is excessive interference, or if the two-way-radio users do not want to hear the paging signals, then CTCSS operation should be used.  In this mode, a low frequency tone is transmitted along with the desired audio.  The receiver will only be enabled if this tone is present at the correct frequency.   To enable this mode, press 2 to select CTCSS, then use the arrow keys to select the desired tone frequency.  Press the "-" or F1 key to accept the frequency and exit the entry mode. 3.3.13  TX Data Delay  This parameter controls the delay between the time the transmitter is turned on and the start of the transmit preamble for POCSAG pages.  The delay is given in milliseconds. 3.3.14  Shift CPU Clock In rare cases, the desired receive frequency may coincide with computer noise generated by the internal CPU.  This option enables the user to change the CPU's timing, which may shift the CPU's computer noise away from the desired receive frequency. 3.3.15  CW Identification Call Sign In many cases, the rules and regulations under which the Peoplefinder II is licensed by the government require that the station's Call Sign be transmitted at regular intervals for identification purposes using Morse Code.  The
«ProductName»      User Manual      7M303-1 Rev A2  Page 15 Peoplefinder II sends the Call Sign (with CTCSS turned off so the mobile radio users won't hear it) every 10 minutes if the Call Sign has been programmed.  This feature is disabled when the unit comes from the factory. To enable this feature, press 5 from the main configuration menu.  At the prompt, enter your station's Call Sign from your license as follows:  Numbers are entered directly from the keypad.    Letters and other special symbols are entered from the keypad by pressing the arrow keys.  Alternatively, an external keyboard may be used to enter alphanumeric characters directly as typed.  Press the F2 key to accept the displayed letter when using the unit's keypad or to enter a "space" character which is displayed as a "_" and results in a pause in the Morse Code.    Press the DEL key to delete errors or to disable CW Identification by totally clearing the display.    Press the F1 or "-" key to accept the Call Sign and exit the menu.  Up to 19 characters may be contained in the CW Identification string.
«ProductName»      User Manual      7M303-1 Rev A2  Page 16 4  Program Mode The Program Mode is used to program CAP codes, add pagers, delete pagers, assign pagers to groups, configure the alarm pages, and set up various features of the Peoplefinder II. To enter the programming mode, press the dash "-" key on the keypad or the ESC key on the external keyboard.  The Peoplefinder II  will prompt you to enter the password.  After entering the Program Mode password (7531) and pressing F1, you can select one of the following menu items: 1 = Assign Pager Assigns pager CAP codes 2 = Assign Group   Assigns pagers to groups  3 = Test Page   Sends periodic test pages 4 = Alarm Pages   Configures alarm triggered pages 5 = autodial memory  Configures Autodial memories - = RETURN TO PAGE  Return back to the page mode  When you enter the Program Mode you will see the first selections.  Use the UP/DOWN arrows to scroll through the available options.  To exit the Program Mode, press the - (Program) key or the ESC key.  Any changes you make will automatically be saved.  Note: When the Peoplefinder II is in the Program Mode, it will revert back to the Page Mode if it is idle (no keyboard inputs) for two minutes, except that test pages may be sent for an unlimited period of time. 4.1  Assign Pager All pagers have an ID code, commonly referred to as a CAP code.  It is a long number, difficult to remember, and may change if a pager is replaced or in for repair.  To make paging a pager easy, the Peoplefinder II uses a database stored in its memory to remember every pager's CAP code.  Within the Peoplefinder II, every pager is assigned a Pager Number.  Because pagers only recognize CAP codes, the Peoplefinder II must translate the pager number into the proper CAP code.  The 1 - Assign Pager menu is used for this function.  1. Begin by entering the Programming Mode as described above, and pressing the number 1 key.  The Peoplefinder II will respond with:  PAGER No =   F1:OK F2:BACK -:EXIT Note that the F1 key is used to select an entry, the F2 key goes back to the previous menu item and the - key exits this mode. 2. Enter the number for the pager you wish to add to the database.  For example, to add a pager number "15" to the database press 1 then 5 then F1.   3. Next, you will be prompted to activate or deactivate the pager.  Press F1 to activate it, or press an arrow key to switch between Y and N on the display to deactivate it.  Press F1 when the correct response has been chosen.  4. Next, tell the Peoplefinder II what type of pager is being assigned.  For convenience, the unit will display the type of pager previously selected.  Press the arrow keys to cycle through the list of possible pager types.  The possible types are: POCSAG 512, POCSAG 1200 and POCSAG 2400.  An option is available which also supports TWO TONE pager types.  Note that the OSMAC system must have all pagers set to 512 baud POCSAG. Once the correct paging format type is in the display, press the F1 key on the keypad or ENTER on the external keyboard.  5. After programming the type, you must program in the function type of the pager being used.  The function type for POCSAG pagers is one of the following:
«ProductName»      User Manual      7M303-1 Rev A2  Page 17  TONE     (pager just beeps)  NUMERIC   (pager beeps and displays numbers)  ALPHA    (pager beeps and displays numbers and letters.)    The function type for TWO TONE pagers or GROUP TONE pagers is one of the following:  TONE ONLY   (send page tones only)  TONE+ALERT   (send an alert sound after sending the page tones)   TONE+VOICE   (permit phone caller to speak to the pager after sending page tones.)    TONE+PATCH   (initiate a phone patch after sending the page tones) 6. Press the arrow keys to cycle through the list of functions.  Press the F1 key when the correct function is displayed.  7. If TONE+ALERT or TONE+VOICE was selected, then you will be asked to specify the duration of the alert or the voice connection after the paging tones have been sent.  You may give a value between 0 and 31 seconds.  Entering 0 will cause an alert tone of 1/2 second or use the default voice duration of 15 seconds. 8. If a TWO TONE pager has been selected, you will be asked to select the tone plan for the pager.  Use the arrow keys to scroll through the supported plan types.  If the tone plan for your pager isn't listed, then the pager's tone frequencies must be entered using the database upload command. 9. Once a pager number is entered, the Peoplefinder II will respond with a prompt asking for the CAP code for this pager.   If the pager number was already in the database, it will display the CAP code already programmed.  If it was not in the database, the CAP code will default to the pager number.   To edit the CAP code, use the DEL key to backspace over it.  Press F1 to enter the new CAP code. 10. If a TWO TONE pager has been selected, you may be asked to specify whether the "diagonal frequency" is the first or second tone.  Alternatively, you may select a "group tone" for the pager.  This will send a single tone to the pager with a pre-determined duration. 11. The Peoplefinder II restart back at the PAGER NO =  prompt.  It will automatically increment to the next pager number.   Press the - to exit the Program Mode when all of the pagers have been entered into the database.  Your entries into the pager database will then be saved in the internal FLASH memory.  4.2  Assigning a Group The Group-Page feature is used to send the same page to a number of different pagers.  Groups have numbers just like pagers, and once you define a group and its members, you send pages to the group just as if it were a single pager.  When you assign a number to a group, it is important that the number is not the same as any individual pager.   There is a limit to the number of pagers that may be assigned to any one group.  This is listed in the Specifications section of the Peoplefinder II User Manual.  1. To do the group assignments, select 2-Assign GROUP from the program mode menu.  The display will then show: GROUP NUMBER =  SELECT GROUP 2. Enter the number of the group you wish to work on and then press the F1 key.  Valid group numbers are 1 through 16.  The display will then show:
«ProductName»      User Manual      7M303-1 Rev A2  Page 18 GROUP  X  PAGER NN assign pager number Where X is the group number you wish to work on and NN is the pager number assigned to this group.  Important Note: when you wish to page this group, you will enter the pager number NN for it, not the group number.   3. Use the DEL key to backspace over NN if you wish to change the pager number this group is referred to by. If the pager number NN is already assigned to an active pager, the  will not allow you to assign that number to the group and the pager number will be erased.  If you wish to use NN for a group number instead of an individual pager, you must first de-activate the pager. Section 3.1 describes how to deactivate a pager. Once the pager number for this group is set, press the F1 button. The following prompt will appear. GROUP  X  = numeric SELECT GROUP FUNC 4. Using the arrow keys, select the function (numeric, alpha or tone) for this pager group.  Members of the group may be of any type, but this selection will determine the prompt to the user when a page to this group is initiated.   Press F1 when your selection is made. The display will change to : GROUP  X   MEMBER NN ENTER MEMBER NUMBER 5. X will be the group number you are currently working on, and NN will be a number corresponding to the member number you wish to edit.  The first group member you enter will be member 1.  The second one you enter will be member 2 and so on.  The display always first shows the next member number you can enter a new member as. Use the UP/DOWN arrows if you wish to scroll through the members, or press the DEL key to edit the member number and manually enter the member number to edit. Press F1 key when you are ready to edit/add the selected group member. The display will then show: MEMBER NN =  ENTER PAGER NUMBER 6. Enter the number of the pager you wish to add to the group.  For example if you wish to add pager number 123 to the group, then enter 1 2 3  and then press the F1 key.  Use the DEL key to backspace over any entry if you wish to edit it.  Note that:  To see the pagers in the database are members of this group, you can use the UP/DOWN arrow key to scroll through the members of the group.   To delete a member, at the MEMBER NN = prompt, use the DEL key to erase its number from the screen, and press the F1 key.  7. To finish entering pagers to this group, press the - key.
«ProductName»      User Manual      7M303-1 Rev A2  Page 19 4.3  Sending Test Pages The test page mode may be used to check the range of the system.  With this mode, the Peoplefinder II will automatically generate a page to pager number "0" every ten seconds.   1. Before using this feature, pager number "0" must be programmed as described above.   2. To enable this feature, enter the program mode and press 3.  The display will show: PAGING pAGEr 0 dash (-) to exit 3. Press the - key to return to the programming mode menu.  4.4  Alarm Pages The Peoplefinder II has 8 alarm inputs.  These digital inputs are used to generate pre-programmed pages, each with its own pre-programmed message to any pager, or group of pagers. These may be used for alarms, but they may also be used to simply generate pre-programmed pages.  If no message has been programmed, then no page will be sent.  This facilitates situations in which messages are only desired for one of the two states. The inputs may be connected to normally-open switches or contacts.  When any input is pulled low to ground, it will generate a pre-programmed page. When any input is pulled high or allowed to "float high", it will generate a different pre-programmed page.  Alternatively, alarm pages may be initiated from an external keyboard.  Hold down the CTRL key and then press a number key that corresponds to the alarm input number to send the "Alarm Low" message.  Hold down the SHIFT key also to send the "Alarm High" message.   Note that the alarm inputs are not protected from lighting, so the wires must not be run out of doors.  See Section 9.2 for details regarding the wiring of the alarm input connector.  To set up the alarm pages, the user must perform the following steps: 1. Put the unit into the program mode.  2. Press 4 to enter the Alarm sub-menu.  3. When the ALARM NUMBER =  prompt is shown, enter the number of the alarm you wish to configure. Press the F1 key.  4. The Peoplefinder II will display AlaRM x PAGER on the top line, and the pager number that will be paged when the alarm is triggered.  Erasing the pager number disables the alarm.  Enter the number of the pager you wish to have paged when the selected alarm input is triggered. Press F1 when done. 5. Peoplefinder II will display ALARM low MSG: on the top line of the LCD.  On the second line, you may enter or edit the message to be sent when the alarm input goes low. Press F1 when the message has been entered.  6. Peoplefinder II will display ALARM hi MSG: on the top line of the LCD.  On the second line, you may enter or edit the message to be sent when the alarm input goes high. Press F1 when the message has been entered.  When entering the alarm messages, the unit's keys operate as follows:  Numeric keys are used to enter numbers  F4 or UP keys select the next letter of the alphabet  F3 or DOWN keys select the previous letter of the alphabet  - key enters a "dash" character  F2 key enters a space character or moves to the next character position to the right  DEL key deletes a character and moves to the next character position to the left  F1 key accepts the entry and exits back to the previous menu.   Alphanumeric characters may alternatively be entered directly from an external keyboard  7. Press the F1 key to return to the programming mode menu.
«ProductName»      User Manual      7M303-1 Rev A2  Page 20 5  Diagnostics 5.1  Built-in Diagnostics If the user selects DIAGNOSTICS MODE from the Configuration Menu, the  goes into a diagnostics mode which allows the operator to exercise many of the ’s hardware functions and to help troubleshoot any problems with connections to the unit.   Connections to the radio, speaker and microphone may be independently toggled for any desired test configuration. The Functions that are available are: F1 - Toggle the connection to the phone line between On and Off F2 - Toggle the radio connection between Off, Receive and Transmit modes F3 - Connect the microphone to the transmitter  F4 - Toggle the unit's speaker between On and Off 1 – Pager Bit Test  (sends alternating 1010 pattern at a specific baud rate and on/off timing)  1 – 512 baud  2 – 1200 baud  3 – 2400 baud 2 –Sound Tests  – Press any of the number keys or function keys to play one of the first 14 sounds  – Alternatively, press the arrow keys to select sounds 3 – DTMF tests  – Press one of the 16 lower buttons to generate DTMF tones in "encode" modes  – Press the "down arrow" key to exit the DTMF test mode  – Press the "up arrow" key to toggle between the following test modes:     - Encode DTMF continuously     - Decode DTMF from the radio or phone line, depending on which was enabled last     - Encode DTMF in 50 mS beeps     - Encode only the low tone continuously     - Encode only the high tone continuously 4 – DAC ramp test  (exercises the sound DAC)   – Press number keys to change the ramp frequency 5 – LCD display tests  – Press the - key to sequence between the tests 6 – Keypad and keyboard test  – Keypad codes and external keyboard scan codes are displayed when keys are pressed  – Press the - key on the keypad twice to exit this test mode 7 – Alarms & Ring (displays the status of the alarm inputs and phone ring detection circuitry) 5.2  Remote Diagnostics Test functions may also be initiated remotely via a two-way radio which is equipped with a 16 tone DTMF keyboard.  Key Sequence  Function  * A Send an "A" DTMF tone to the radio continuously for a period of time. * B Send all 16 DTMF tones plus all 8 single tones to the radio. * D Transmit the CW Identification Call Sign in Morse Code.  CTCSS is turned on.
«ProductName»      User Manual      7M303-1 Rev A2  Page 21 6  Serial Port Protocols The Peoplefinder II paging transmitter supports three different serial port communication protocols.  Each protocol has its own uses, and the correct one for one application may not be the correct one for another.  The Peoplefinder II must be configured to support the desired protocol, and only one protocol may be used at a time. The three protocols supported are: TAP (also called IXO)  The Telocator Access Protocol is an industry standard protocol for communications between paging entry devices and a paging terminal.  Individual pagers can be sent individual messages.  COMP1  This protocol is a simple way to send data to one pager.  It is designed to allow a person with a simple computer terminal to type a message into the Peoplefinder II. The Peoplefinder II must be pre-configured with the CAPCODE of the pager to send the data to, and all data sent into the serial port of the Peoplefinder II will be sent to that one pager.  COMP2  COMP2 is similar to COMP1, except each page requires two lines of text to be entered. The first line is the pager number to send the page to, and the second line is the alpha or numeric message to send to that pager.  6.1  TAP The Telocator Alphanumeric Protocol, or  TAP protocol as it is called, is used to send pages to communicate paging information to a transmitter.  It is a sequence of characters sent over a serial interface to a transmitter.  The transmitter must parse the commands, and take the appropriate actions.   The following sections describe how the TAP protocol works.  It assumes that the device communicating to the Peoplefinder II Station is directly connected to it via a serial cable.  If other means are used (i.e. modem) then the modem connection must first be established. For the purposes of this manual, the Peoplefinder II is assumed to be the transmitter, and the device connected to its serial port is the "Entry Device".  Typical entry devices are computers, paging terminals, and alarm monitors.  Characters listed in brackets <xx> are ASCII codes, and the values for them are listed at the end of this document.  Initiating a Page Entry Device Peoplefinder II Action Comment <CR>  The Entry Device should send a <CR> at two second intervals until the Peoplefinder II responds with the characters ID=.  The <CR> is an ASCII code 13h.   ID=<CR><LF> The Peoplefinder II will respond within one second of the <CR>, and it does not end the ID= prompt with a <CR> or a <LF>.
«ProductName»      User Manual      7M303-1 Rev A2  Page 22 After initiating a page, and receiving the ID= prompt, the Entry Device can respond in one of two different ways.  One way puts the Peoplefinder II into an Automatic Mode, and the other ways puts it into a Manual Mode.  Automatic Entry of a Page Entry Device Peoplefinder II Action Comment <ESC>PG1<CR>  The Entry Device tells the Peoplefinder II transmitter that it wants to automatically send a POCSAG page by ending this sequence.   <CR><ACK><CR> or <CR><NAK><CR> or <ESC><EOT><CR> The Peoplefinder II will respond within one second of the ACK sequence signifying that the Entry Device has successfully logged on to the Peoplefinder II.  If paging entries cannot be accepted, it will respond with the NAK sequence or the ETX sequence, which should force the Entry Device to disconnect.   <ESC> [p <CR> This "go ahead" sequence tells the Entry Device that it is OK to go ahead and send over the information for the first page or pages. The p is always the lower case "p".  <STX> PagerID<CR> Message<CR> <ETX> Checksum <CR>  This Pager/Message Sequence Block tells the Peoplefinder II the ID (the Pager Number in the Peoplefinder II's database) of the pager this the Message is to be sent to.  The checksum is computed as shown later in this document. The total number of characters sent from the Entry Device per sequence should not exceed 255. Repeat the above Pager/Message Sequence Block as many times as required, if more pages are to be sent.   <EOT> <CR>  When the Entry Device does not want to send any more pages, it sends this EOT sequence, to tell the Peoplefinder II that it is finished with this automatic session.   Pages Accepted <CR> or Invalid Page Entered<CR> or <Message><CR> One of these status messages will be returned at the end of the session.  They are for information purposes only.   <CR><RS><CR> This is only sent if there was an error in this session, probably due to an invalid pager ID or a message type mismatch.   PAGING EXCHANGE DISCONNECT <CR> <ESC> <EOT> The End of Transaction message sent from the Peoplefinder II to the entry device, telling it to disconnect.
«ProductName»      User Manual      7M303-1 Rev A2  Page 23  Manual Entry of a Page Entry Device Peoplefinder II Action Comment M<CR>  The Entry Device tells the Peoplefinder II transmitter that it wants to manually send a POCSAG page, by ending the M.   ENTER PAGER NUMBER: The Peoplefinder II will respond within one second of the M sequence signifying that the Entry Device has successfully logged on to the Peoplefinder II, and it is ready to receive paging info.  The Peoplefinder II begins by responding with this prompt.  PagerID<CR>  The user responds with the ID of the pager he wishes to page.    Enter Alpha Message: or Enter Numeric Message: The Peoplefinder II responds with one of the following messages, depending upon the type of pager that the PagerID is assigned to. Message<CR>  The user enters a message to send to the pager.  Sending Message...<CR> The Peoplefinder II displays this message as it sends the message to the pager.   MessageSent<CR> or Can't Deliver to xxxxxxx<CR> or Too Slow. Goodby.<CR> or Two many errors. Goodby. <CR> One of these messages will then be sent from the Peoplefinder II, depending upon the current situation with the page that was entered.  The serial port has a 45 second activity time, and will force and end to the manual session if the user does not complete the page in that time.   6.2  TAP Protocol Issues 6.2.1  Timing The Peoplefinder II will wait for a response to come back from the Entry Device. If a response is not received before the pre-programmed time-out period, the Peoplefinder II will cancel the current transaction, sending the <ESC> <EOT> <CR> sequence. 6.2.2  Line Feeds The Peoplefinder II will ignore all <LF> characters it receives.  The Entry Device may send a <LF> with any <CR>. XOFF In the very unlikely event that the user enters more pages than the Peoplefinder II can queue up, the Peoplefinder II will send the <XOFF> character before sending a carriage return.  It will send the <XON> character when buffer space is available for more pages.  If the Peoplefinder II does not receive data within 10 seconds after sending an <XON>, it will send another <XON>.
«ProductName»      User Manual      7M303-1 Rev A2  Page 24 6.2.3  EOT Whenever the Peoplefinder II terminates a session by sending the <EOT><CR> sequence, it will drop the DTR signal on the RS-232 signal for 250mS.  This will normally cause any modem connected to it to disconnect.  6.3  Sending Multiple-Line Pages If you wish a message to continue on another line of a multi-line pager, you cannot send the <CR> return into the serial port.  Use the TAB character instead of a <CR>. The Peoplefinder II will translate it to a <CR> when it sends the page to the pager.  6.4  Computing the Checksum The checksum is a simple arithmetic sum of the 7-bit values of all characters preceding it.  The checksum reported is the least significant 12 bits of this summation, converted to BCD ASCII.   Checksum Example: STX 000 0010 1 011 0001 2 011 0010 3 011 0011 <0CR> 000 1101 A 100 0001 B 100 0010 C 100 0011 <CR> 000 1101 ETX 000 0011 Total 10111 1011 Convert to BCD 1   0111 1011 Answer in BCD ASCII 1      7 ;  6.5  COMP1 COMP1 allows a "dumb terminal" to be used to send a page, although any device that can output RS-232 data can be used.   All data entering the serial port is sent to pager number 0.  The reception of a <CR> initiates the page.   Manual Entry of a Page Entry Device Peoplefinder II Action Comment <Message><CR>  The Entry Device (in this case it is often a user on a terminal) types in the message to send to a pre-set pager.   Characters are echoed back.
«ProductName»      User Manual      7M303-1 Rev A2  Page 25 6.6  COMP2 COMP2 allows a "dumb terminal" to be used to send a page, although any device that can output RS-232 data can be used.  It has the added capability of selecting which pager to send the data to.  All data entering the serial port is sent to a specified pager.  The reception of a <CR> initiates the page.  If the last <CR> is not sent within the pre-programmed timeout period, the Peoplefinder II will abort this transaction, and begin waiting for a new <Page #> entry.  Manual Entry of a Page Entry Device Peoplefinder II Action Comment <Page #><CR> <Message><CR>  The Entry Device (in this case it is often a user on a terminal) type in the message to send to a pre-set pager.   Characters are echoed back.   6.7  ASCII control characters For your reference, here is a list of the commonly used ASCII control characters.  Decimal Hex Code  Decimal Hex Code 00 00 <NUL>  16 10 <DLE> 01 01 <SOH>  17 11 <XON> 02 02 <STX>  18 12 <DC2> 03 03 <ETX>  19 13 <XOFF 04 04 <EOT>  20 14 <DC4> 05 05 <ENQ>  21 15 <NAK> 06 06 <ACK>  22 16 <SYN> 07 07 <BEL>  23 17 <ETB> 08 08 <BS>  24 18 <CAN> 09 09 <TAB>  25 19 <EM> 10 0A <LF>  26 1A <SUB> 11 0B <VT>  27 1B <ESC> 12 0C <FF>  28 1C <FS> 13 0D <CR>  29 1D <GS> 14 0E <SO>  30 1E <RS> 15 0F <SI>  31 1F <US>
«ProductName»      User Manual      7M303-1 Rev A2  Page 26 7  Database Transfer For convenience managing databases containing a large number of pagers, for backup purposes and to facilitate cloning databases from one unit to another, the Peoplefinder II database may be uploaded and downloaded from a host computer which is connected to either serial port which is configured for the TAP protocol. 7.1  Database Format The Peoplefinder II database may be uploaded or downloaded as ASCII characters which can readily be transferred, stored and/or edited as desired.  The format of the database output is as follows: DB1 VERSION, {VERSION}, {LANGUAGE}, {OPTIONS},  SERIAL, {PORT}, {BITS}, {STOP}, {PARITY}, {FLOW}, {BAUD}, {TAP-TO}, {COMP-TO}, {MAN-TO}, {PROTO},  MODE, {SPKR}, {BUSY}, {REMOTE}, {CALL}, {AP-TIMER}, {VOICE}, {WARMUP}, {RINGS}, {DONE}, RADIO, {T-REF}, {T-FRQ}, {T-TONE}, {BW}, {R-REF}, {R-FRQ}, {R-TONE}, {CD}, {DATA}, {TYPE}, {TR}, {CPU}, {DLY}, {PWR},    AUTODIAL, {MEMORY NUM}, {PHONE NUM},  PAGER, {0-999}, {TYPE}, {CAPCODE}, {FORMAT}, {GROUP}, {ACTIVE}, {DUR-A}, {DUR-B}, {DUR-C},  GROUP, {NUMBER}, {PAGER NUM}, {MEMBERS}, {SPARE}, {MEMBER 1}, …{MEMBER N},  ID, {ID STRING},  DONE  Where: DB1     Signifies that the database download follows VERSION    Signifies that the version string follows {VERSION}  Firmware version string {LANGUAGE}  Language of the voice prompts {OPTIONS}  Firmware options SERIAL    Signifies that this line is data for a serial port {PORT}    Port number for this line's data {BITS}    Number of data bits (0= 7 bits, 1= 8 bits) {STOP}    Number of stop bits (0= 1 bit, 1= 2 bits) {PARITY}    Parity (0= No Parity, 1= Odd, 2= Even) {FLOW}    Flow control (0= None, 1= Xon/Xoff, 2= RTS/CTS) {BAUD}    Baud rate (0= 300, 1= 600, 2= 1200, 3= 2400, 4= 4800, 5= 9600, 6= 19200) {TAP-TO}    Timeout for TAP protocol in seconds {COMP-TO}  Timeout for COMP protocol in seconds {MAN-TO}    Timeout for manual entry mode in seconds {PROTO}    Port protocol (0 = TAP, 1 = COMP1, 2 = COMP2) MODE      Signifies that this line is data for mode settings {SPKR}    Speaker enable mode on/off {BUSY}    Busy channel lockout on/off {REMOTE}   Remote enable on/off {CALL}    Call forwarding on/off {AP-TIMER}  Autopatch timer in seconds {VOICE}    Voice Prompts on/off {WARMUP}  Warmup signal on/off {RINGS}    Number of rings before the phone is answered  {DONE}    Autopatch delay from entry of final phone number digit to start of dialing
«ProductName»      User Manual      7M303-1 Rev A2  Page 27 RADIO     Signifies that this line is data for the radio transceiver {T-REF}    Transmit reference frequency in Hz {T-FRQ}    Transmit frequency in Hz {T-TONE}    Transmit CTCSS code (-1 = CTCSS off) {BW}    Transmit Bandwidth (0= wide, 1= narrow) {R-REF}    Receive reference frequency in Hz {R-FRQ}    Receive frequency in Hz {R-TONE}    Receive CTCSS code (-1 = CTCSS off) {CD}    Carrier detect inversion on/off {DATA}    Transmit data inversion on/off {TYPE}    Transceiver type code  {0= NO_TX, 1= VHF 204, 2= UHF, 3= VHF 3464} {TR}    Transmit/Receive switching delay in mS, used for autopatch sampling {CPU}    Number of CPU wait states, used to shift CPU noise from receive channels {DLY}    Delay from Transmitter ON to start of POCSAG preamble in mS  {PWR}    Transmitter Power Control word (Read only, used by 3412-X radios)  AUTODIAL    Signifies that this line is data for an autodial memory {MEMORY NUM}  Memory number {PHONE NUM}  Phone number ID        Signifies that this line contains the CW ID for the unit {ID STRING}  The ID String of the unit PAGER    Signifies that this line is the data for a pager {0-999}     Pager number for the data on this line {TYPE}    Pager type:  ALPHA, NUMERIC, TONE, ALERT, VOICE or PATCH {CAPCODE}  Pager CAPCODE.  If the pager is a group it will be the group number minus 1.      For two-tone pagers, if DUR-A is not zero, CAPCODE contains frequencies of the     two tones with the first tone's frequency in units of 1/10 Hz in bits 0 to 15 and the     second tone's frequency in units of 1/10 Hz in bits 16 to 31. {FORMAT}   Paging format: POC512, POC1200, POC2400, TWO-TONE or ONE-TONE {GROUP}    Is either Y if it is a group pager, or N if it is not a group pager {ACTIVE}    Is either Y is the pager is enabled, or N if it is de-activated {DUR-A}    Duration of first tone in units of 50 mS for two-tone pagers with random frequencies,      0 otherwise. {DUR-B}    Duration of second tone in units of 50 mS for two-tone pagers with random       frequencies, 0 otherwise. {DUR-C}    Duration of the two-tone pager's alert tone or the voice connection in seconds. GROUP    Signifies that this line is the data for a group of pagers {NUMBER}   Group number (1-16) {PAGER NUM}  Pager number that references this group {MEMBERS}  Number of pagers assigned to this group {SPARE}    A blank entry for future use {MEMBER 1}  The pager number for the first member. All other members follow this one, separated        by commas. {MEMBER N}  This is the pager number for the final member of the group DONE    This entry signifies the end of the database.  7.2  Retrieving the Database The Peoplefinder II will send the contents of its database out the serial port when it is given the command <ESC>SDB<CR>. The database is sent out at the currently configured baud rate in an ASCII format, with commas between the parameters and a <CR> at the end of each line.
«ProductName»      User Manual      7M303-1 Rev A2  Page 28 Note that the "ONE-TONE" pagers in the following example file are used to generate test tones of 5 seconds duration at a frequency of (Pager Number) X 10 Hz. Example Output of the database: DB1 VERSION,307D51,ENGLISH,1, SERIAL,0,0,0,2,0,5,30,60,90,0, SERIAL,1,0,0,2,0,5,30,60,90,0, MODE,1,0,1,1,10,1,1,1, RADIO,6250,462850000,-1,0,6250,462850000,-1,0,0,2,50,2,20, AUTODIAL,0,8531212, AUTODIAL,1,7521011__225, AUTODIAL,2,, AUTODIAL,3,, AUTODIAL,4,, AUTODIAL,5,, AUTODIAL,6,, AUTODIAL,7,, AUTODIAL,8,, AUTODIAL,9,, ID,WX6L , PAGER,0,NUMERIC,100,POC512,N,Y,0,0,0, PAGER,1,NUMERIC,1,POC512,N,Y,0,0,0, PAGER,2,ALPHA,2,POC512,N,Y,0,0,0, PAGER,3,ALPHA,3,POC512,N,Y,0,0,0, PAGER,4,NUMERIC,4,POC1200,N,Y,0,0,0, PAGER,5,NUMERIC,5,POC1200,N,Y,0,0,0, PAGER,6,ALPHA,6,POC1200,N,Y,0,0,0, PAGER,7,ALPHA,7,POC1200,N,Y,0,0,0, PAGER,8,NUMERIC,8,POC2400,N,Y,0,0,0, PAGER,9,NUMERIC,9,POC2400,N,Y,0,0,0, PAGER,10,ALPHA,10,POC1200,N,Y,0,0,0, PAGER,11,NUMERIC,10,POC1200,N,Y,0,0,0, PAGER,12,TONE,120,TWO-TONE,N,Y,0,0,0, PAGER,13,TONE,130,TWO-TONE,N,Y,0,0,0, PAGER,14,ALERT,140,TWO-TONE,N,Y,0,0,5, PAGER,15,ALERT,150,TWO-TONE,N,Y,0,0,5, PAGER,20,ALPHA,20,POC512,N,Y,0,0,0, PAGER,21,ALPHA,21,POC1200,N,Y,0,0,0, PAGER,22,ALPHA,22,POC2400,N,Y,0,0,0, PAGER,30,TONE,327683000,ONE-TONE,N,Y,0,0,0, PAGER,40,TONE,327684000,ONE-TONE,N,Y,0,0,0, PAGER,50,TONE,327685000,ONE-TONE,N,Y,0,0,0, PAGER,60,TONE,327686000,ONE-TONE,N,Y,0,0,0, PAGER,70,TONE,327687000,ONE-TONE,N,Y,0,0,0, PAGER,80,TONE,327688000,ONE-TONE,N,Y,0,0,0, PAGER,90,TONE,327689000,ONE-TONE,N,Y,0,0,0, PAGER,100,TONE,327690000,ONE-TONE,N,Y,0,0,0, PAGER,110,TONE,327691000,ONE-TONE,N,Y,0,0,0, PAGER,120,ALPHA,12000,POC1200,N,Y,0,0,0, PAGER,123,ALPHA,123,POC512,N,Y,0,0,0, PAGER,130,TONE,327693000,ONE-TONE,N,Y,0,0,0, PAGER,140,TONE,327694000,ONE-TONE,N,Y,0,0,0, PAGER,150,TONE,327695000,ONE-TONE,N,Y,0,0,0, PAGER,160,TONE,327696000,ONE-TONE,N,Y,0,0,0, PAGER,170,TONE,327697000,ONE-TONE,N,Y,0,0,0, PAGER,180,TONE,327698000,ONE-TONE,N,Y,0,0,0, PAGER,190,TONE,327699000,ONE-TONE,N,Y,0,0,0, PAGER,200,TONE,327700000,ONE-TONE,N,Y,0,0,0, PAGER,201,PATCH,201,TWO-TONE,N,Y,0,0,0, PAGER,210,TONE,327701000,ONE-TONE,N,Y,0,0,0, PAGER,220,TONE,327702000,ONE-TONE,N,Y,0,0,0, PAGER,230,TONE,327703000,ONE-TONE,N,Y,0,0,0, PAGER,240,ALPHA,24000,POC2400,N,Y,0,0,0, PAGER,250,TONE,327705000,ONE-TONE,N,Y,0,0,0, PAGER,260,TONE,327706000,ONE-TONE,N,Y,0,0,0, PAGER,270,TONE,327707000,ONE-TONE,N,Y,0,0,0, PAGER,280,TONE,327708000,ONE-TONE,N,Y,0,0,0, PAGER,290,TONE,327709000,ONE-TONE,N,Y,0,0,0, PAGER,300,TONE,327710000,ONE-TONE,N,Y,0,0,0,
«ProductName»      User Manual      7M303-1 Rev A2  Page 29 PAGER,310,TONE,327711000,ONE-TONE,N,Y,0,0,0, PAGER,320,TONE,327712000,ONE-TONE,N,Y,0,0,0, PAGER,512,ALPHA,512,POC512,N,Y,0,0,0, PAGER,600,TONE,655380000,TWO-TONE,N,Y,20,20,0, PAGER,700,ALPHA,1,POC512,Y,Y,255,255,31, PAGER,800,VOICE,800,TWO-TONE,N,Y,0,0,5, PAGER,900,ALPHA,0,POC512,Y,Y,255,255,31, PAGER,990,NUMERIC,990,POC1200,N,Y,0,0,0, PAGER,991,ALPHA,991,POC1200,N,Y,0,0,0, PAGER,992,TONE,992,POC1200,N,Y,0,0,0, PAGER,993,TONE,993,TWO-TONE,N,Y,0,0,0, PAGER,994,ALERT,994,TWO-TONE,N,Y,0,0,5, PAGER,995,VOICE,995,TWO-TONE,N,Y,0,0,15, PAGER,996,PATCH,996,TWO-TONE,N,Y,0,0,0, PAGER,997,TONE,2097352,TWO-TONE,N,Y,0,0,0, PAGER,998,TONE,4194504,TWO-TONE,N,Y,0,0,0, PAGER,999,TONE,200,TWO-TONE,N,Y,0,0,0, GROUP,1,900,6,,2,3,6,7,10,11 GROUP,2,700,5,,2,4,6,8,10 DONE  7.3  Restoring/Uploading the Retrieved Database If the database is stored on a disk in the format shown above, it may be re-loaded into the Peoplefinder II.  Use a terminal emulation program to send the ASCII file into either serial port in a plain-text format.  The serial port must be configured for the TAP protocol. The Peoplefinder II will answer every line sent into it with an OK> if the line was acceptable, or ER> if there was an error in it.  If any errors occur during uploading, a message will be displayed at the end of the upload sequence and the information received will not be saved.  If this occurs, reduce the data rate of the port in use or enable hardware flow control, then retry the upload operation.  Note that the “DB1” sequence in the first line tells the Peoplefinder II that a database file is going to be sent to it.  The word “DONE” at the end of the file tells the Peoplefinder II that the file has been sent.  Once the word DONE is received by the Peoplefinder II, it will copy the database into its FLASH memory only if no errors were detected. 7.3.1  Erasing Pagers or Groups from the Database Uploading the database file to the Peoplefinder II only adds and re-programs the pagers and groups specified.  It does not erase other pagers with entries stored in the unit's memory.  If you want the pager database erased without changing any of the unit's setup parameters, use a text editor to add a line before the first PAGER entry in the database.  The only characters on the line should be:  ERASEDATABASE This will tell the Peoplefinder II to erase whatever is in its pager database before it adds the new pagers and groups from the ASCII file.  If you only wish to erase the group information, and not the individual pagers, put a line in the file that reads: ERASEGROUPS  7.3.2  Programming Two-Tone Pagers with Non-Standard Frequencies Two-tone pagers using non-standard frequencies and durations may be programmed via the database upload command.  Use a text editor to create an entry in the database file for the pager as follows before uploading the file to the unit: PAGER,{0-999},{TYPE},{CAPCODE},TWO-TONE,N,{ACTIVE},{DUR-A},{DUR-B},{DUR-C}
«ProductName»      User Manual      7M303-1 Rev A2  Page 30 Where: PAGER  Signifies that this line is the data for a pager {0-999}   Pager number for the pager {TYPE}  Pager type:  TONE, ALERT, VOICE or PATCH {CAPCODE}  Bits 0 to 15 =  First tone's frequency in units of 1/10 Hz    Bits 16 to 31 = Second tone's frequency in units of 1/10 Hz {ACTIVE}  Is either Y is the pager is enabled, or N if it is de-activated {DUR-A}  Duration of the first tone in units of 50 mS  {DUR-B}  Duration of the second tone in units of 50 mS.  Set to 0 for group-tone pagers. {DUR-C}  Duration of the two-tone pager's alert tone or the voice connection in seconds.      Example: Program pager number 320 with a 534.7 Hz tone for 300 mS, followed by a 972.8 Hz tone for 800 mS, then an alert tone for 5 seconds: TYPE =   ALERT CAPCODE =   (534.7 Hz * 10)  + (972.8 Hz * 10 * 65536) = 637539555 DUR-A =  300 mS / 50 mS = 6 DUR-B =  800 mS / 50 mS = 16 DUR-C =   5 Database Entry =  PAGER,320,ALERT,637539555,TWO-TONE,N,Y,6,16,5 7.3.3  Programming One-Tone Pagers One-tone pagers or test tones using non-standard frequencies and durations may be programmed via the database upload command.  Use a text editor to create an entry in the database file for the pager as follows before uploading the file to the unit: PAGER,{0-999},{TYPE},{CAPCODE},ONE-TONE,N,{ACTIVE},{DUR-A},{DUR-B},{DUR-C}  Where: PAGER  Signifies that this line is the data for a pager {0-999}   Pager number for the pager {TYPE}  Pager type:  TONE, ALERT, VOICE or PATCH {CAPCODE}  Bits 0 to 15 =  Tone's frequency in units of 1/10 Hz    Bits 16 to 31 = Duration of the tone in units of mS {ACTIVE}  Is either Y is the pager is enabled, or N if it is de-activated {DUR-A}  Set to 0 {DUR-B}  Set to 0 {DUR-C}  Duration of the two-tone pager's alert tone or the voice connection in seconds.   Example: Program pager number 124 with a 1240.5 Hz Tone for 5 seconds, followed by an alert tone for 10 seconds: TYPE =   ALERT CAPCODE =   (5 sec * 1000  * 65536) + (1240.5 Hz * 10) = 327692405 DUR-C =   10 Database Entry =  PAGER,124,ALERT,327692405,ONE-TONE,N,Y,0,0,10
«ProductName»      User Manual      7M303-1 Rev A2  Page 31 7.3.4  Programming the Unit's Configuration The unit configuration data stored in the SERIAL, MODE, RADIO and AUTODIAL entries are normally ignored when the database file is uploaded to the Peoplefinder II as a security feature in order to prevent unauthorized users from changing the unit's configuration.   If it is desired to change the Peoplefinder II's configuration with data downloaded previously from a Peoplefinder II unit, use a text editor to add the following line to the database file immediately after the "DB1" entry: PASSWORD,xxxxxx,[0D] Where xxxxxx is the same password required to access the Configuration Mode from the Peoplefinder II's front panel. Note that the unit's Firmware Version and CW ID String are not changed when uploading the database file.  These entries in the database file are ignored during the upload process. 7.3.5  Keyboard Emulation Key presses from an external keyboard may be simulated from the computer ports for use in automated test stations or other special applications.  As a security feature, the PASSWORD command must have been sent prior to using this feature. To simulate key presses from an external keyboard, use a text editor to add the following line to the database file after the PASSWORD line: KEY,nnn,[0D]    or   KEY,nnn,nnn,nnn, [0D] Where nnn represents the desired keycode represented in decimal ASCII representation. Several keycodes may be placed on a line if desired as indicated above.  Note that the following special numbers are defined:  Decimal ASCII Code Function 1 F1 Key 2 F2 Key 3 F3 Key 4 F4 Key 5 Dash Key 6 Delete Key 7 Down Key 8 Up Key 31 Enter Configuration Mode
«ProductName»      User Manual      7M303-1 Rev A2  Page 32 8  Firmware Updating The firmware in the Peoplefinder II can be loaded with firmware updates via the serial port number 1 (lower of the two serial ports).  Use the following procedure: 1. You may need to reset the Flash memory and reload the database of pagers after loading the new firmware into the unit.  Therefore, before updating the firmware, it is recommended that the pager database be downloaded and saved as described in the "Retrieving the Pager Database" section of this manual. 2. Connect a computer’s serial port to the Peoplefinder II, and on the computer, run a terminal emulation program such as Hyperterminal or ProComm.  Set the baud rate to 38.4kbps, 8 data bits, 1 stop bit, no parity.  3. When powering up the Peoplefinder II, hold the “-” button down.  You should see a sign-on message from the Peoplefinder II that looks like this: PageCenter software installation utility Copyright (c) 1999, Sonik Technologies Corp. San Marcos, CA Version: 306D1   Erase current software and begin download?  4. On the computer, press Y for yes if you would like to load new firmware into the unit.   5. The file name for the Peoplefinder II firmware is 307xxxxL.BIN, where xxxx is the revision code and L is a code for the language of the voice prompts.  If you are interested in a language other than English, contact your distributor for availability.  6. Begin the file transfer of the new firmware from the computer, using either YMODEM or XMODEM.  If one protocol fails to work, try the other.  When the update is complete, the unit will reset and begin operation.  7. Check to see whether the old pager database is compatible with the new firmware version.  If the previously programmed pagers function properly, then the installation is completed and the following steps do not have to be performed.  If the pagers do not function properly, then the following steps must be performed to restore the pager database: 8. Edit the pager database previously saved and add the following on a line by itself before any of the pager entries:       ERASEDATABASE  9. Upload the revised pager database using the procedure described in the "Restoring/Uploading the Retrieved Database" section of the manual.
«ProductName»      User Manual      7M303-1 Rev A2  Page 33 9  External Connectors 9.1  External Transceiver The Peoplefinder II may utilize an internal transceiver, an external transmitter, or an external transceiver.  A 15 pin D-sub connector is located on the rear of the Peoplefinder II to facilitate interfacing an external transmitter or external transceiver to the Peoplefinder II .  The pin-out of this connector is as follows: External Transceiver I/O Connector Pin Out Pin Number Function 1 Ground 2 B+ for the radio. Internally jumper selectable between +8V and +12V. 1 Amp maximum current draw. 3 +8V TX.  This pin floats when in the RX mode, and will be pulled to +8V when in the TX mode. 50 mA maximum current source.  4 +5V for radio. 50 mA maximum current draw.  5 +5VRX.  This pin floats in the TX mode, and will have +5V when in the RX mode. 50 mA maximum current source.  6 TX audio. Approximately 1.7V p-p for full system deviation.   2.5V DC nominal bias on this signal.   7 PTT out.  Open collector output, pulls low to ground when the transmitter’s PA should be on.   8 Do not use and do not connect to anything.  9 Do not use and do not connect to anything.  10 Do not use and do not connect to anything.  11 TX data out.  This is the TTL POCSAG data output in the transmit mode.  12 Receiver signal strength indication input.  Positive voltage represents carrier present on channel. 13 RX audio input. 1.0V p-p for a signal with full system deviation.  14 CTCSS tone encoder output. 15 Rev E hardware and above:  High when sending a POCSAG page, low otherwise.  9.2  Keyboard Connector The Peoplefinder II may be used with standard external keyboards for use with Personal Computers that have PS-2 style connectors.  Only keyboards that are fully compliant with the two-way keyboard signaling protocol will work with the Peoplefinder II.  It has been found that some brands of keyboards do not function properly with the Peoplefinder II due to an incomplete implementation of the signaling protocol by the keyboard. 9.3  Serial I/O Ports The Peoplefinder II has two RS-232 type serial I/O ports on it.  The EIA/TIA RS-232, and the equivalent European CCITT V.28, are electrical standards that cover the signal levels, drive level, and slew rate of compliant devices.  It is important to note that they do not specify baud rates, data formats, or connector pin-outs.  These are set by industry standards and practices.   Equipment using RS-232 ports is grouped into two categories: DTE  Data Terminal Equipment     (computers, mainframes, terminals) DCE Data Communications Equipment   (modems, printers, etc.) The Peoplefinder II is wired as a peripheral (DCE) device.
«ProductName»      User Manual      7M303-1 Rev A2  Page 34 The control lines on the serial port are used for controlling the flow of data and the peripheral attached to the port.  The most signals provided for on RS-232 serial interfaces are shown in the following table: Pin # Name Typical RS-232 Serial Signal Functions 3 TXD Transmit data from the computer to the Peoplefinder II. 2 RXD Receive Data from the Peoplefinder II to the computer. 7 RTS* Request to send data. This is an output from the computer to the Peoplefinder II. It indicates to the Peoplefinder II that it is ready to exchange data.   8 CTS* Clear to send. This is a signal from the Peoplefinder II to the computer indicating that it is OK to send data. 4 DTR* Data Terminal Ready to the Peoplefinder II. This signal indicates to the peripheral that the host is ready to receive data.  1 DCD* Data Carrier Detect from the Peoplefinder II. 9 RI* Not implemented.   6 DSR Data Set Ready from the peripheral.  Indicates the peripheral is ready. 5 GND System Ground  *The hardware flow control signals, RTS, CTS, DTR, DSR, and DCD are active low.  In other words, they are set to binary zero (0) to assert them and binary one (1) to negate them.  Over an RS-232 cable, they are again inverted because RS-232 specification calls for negative logic. Negating RTS is a binary 1, which is a negative voltage on the RS-232 port.   9.4  Auxiliary/Alarm Connector A 15 pin D-Sub female connector is located on the rear of the unit.  This connector has digital inputs used for triggering alarms. It also has contacts for two relay outputs.  The digital inputs may be programmed to automatically generate a page. The relay outputs may be switched on remotely via the radio or console.  Note that all digital alarm inputs have an internal 10K pull-up resistors connected.  Alarms are activated by pulling the input to ground. Open circuit or a TTL/CMOS high level is the inactive state. Do not pull these inputs above 5V.  Auxiliary/Alarm I/O Connector Pin Out Pin Number Function 1 Alarm 8 2 Alarm 7 3 Alarm 6 4 Alarm 5 5 Alarm 4 6 Alarm 3 7 Alarm 2 8 Alarm 1 9 Relay 1 contact A 10 Relay 2 contact A 11 Relay 2 contact B 12 Relay 1 contact B 13 No connection 14 No connection 15 Ground
«ProductName»      User Manual      7M303-1 Rev A2  Page 35 10 Specifications Principles of Operation The Peoplefinder II is a multi-functional unit which can be used to communicate between the built-in speaker/microphone, pagers and two-way radios.  The internal circuitry is comprised of numerous elements as shown on the block diagram below.  These include radio transceiver, microprocessor, front panel I/O, DTMF encoder/decoder, CTCSS encoder/decoder, speech synthesizer (DAC), microphone amplifier, speaker amplifier, analog filters, limiting amplifier and analog switch matrix.  The microprocessor controls all circuitry as needed for the desired communication function. The encoders generate needed audio signals and the decoders detect incoming control signals on the received audio.  Analog switches route the analog signals within the unit.                Peoplefinder II Block Diagram Encoder/Terminal general Paging Format .................................................................... POCSAG ( tone, numeric, and alpha at 512, 1200 or 2400bps) TWO-TONE and GROUP-TONE optional Squelch formats .................................................................. CTCSS or carrier squelch Serial port protocols ........................................................... TAP, COMP2, COMP1 Pager database maximum size ............................................ 1000 individual pagers Maximum page length ........................................................ 250 characters Maximum pre-programmed alarm message ....................... 40 characters Maximum number of pager groups .................................... 16 Maximum number of pagers per group .............................. 75 LCD display size ................................................................ 20 characters X 2 lines Speaker audio ..................................................................... 1 watt maximum at <5% THD Power supply ...................................................................... External 12.0V&5.0VDC, 2A, DIN connector.  Weight ................................................................................ 3.5lbs. Temperature range .............................................................. -10-+40C Processor ............................................................................ 80386EX Non-volatile flash memory size.......................................... 2M bytes External keyboard interface ................................................ Standard PS/2 Control Bus Mic Speaker Antenna   Analog  Switch  Matrix  Radio Transceiver  Front  Panel Filter Limiter DTMF CTCSS DAC  Microprocessor RS232 Port 1 RS232 Port 2 Keyboard Alarm Inputs
«ProductName»      User Manual      7M303-1 Rev A2  Page 36 DTMF signaling timing ...................................................... > 40 mS   (telco receive mode) > 100 mS   (radio receive mode) 100 mS    (telco transmit mode) Alarm/data inputs ............................................................... 8  RF Section Frequencies ........................................................................ VHF and UHF band models available RX channel spacing ............................................................ 12.5kHz/6.25kHz Multimode  TX power output ................................................................  2 watts RF Modulation ................................................................... Frequency Modulation RF Impedance …………………………………………… 50 ohms
«ProductName»      User Manual      7M303-1 Rev A2  Page 37 11 Alignment 11.1  Adjustments The following table lists the internal adjustments.   Reference Designator Function  Rear Panel Squelch/carrier detect threshold level.  Rear Panel LCD Contrast.  R20 Receive audio level.   R16 RX audio bias.   R32 CTCSS encode level.   R34 Paging data level.   R41 Voice limiter.   R60 Microphone gain.   R52 Telco audio to transmitter level.  R69 Telco line driver level.    11.2  Alignment Procedure 11.2.1  General Setup 1. Apply DC power to the unit.  Connect the service monitor to the ANT port.  2. Download the Flash code to the unit if it is not already programmed.  Hold down the "-" key while powering up the unit to enter Flash code programming mode.  See the section on "Firmware Updating" for additional information. 3. Adjust the LCD contrast control on the rear panel of the unit. 11.2.2  Radio Interface This procedure assumes a properly tuned transceiver is installed in the unit.  You will need a DC power source, service monitor, oscilloscope, and DVM.  Full System Deviation =2.5 kHz for Half Channel (12.5kHz BW) versions.   1. Program the unit’s transmit and receive frequencies.  Disable sub-audible signaling.   2. Generate an RF carrier on the receive frequency, 1 kHz tone, 60% FSD = 1.5 kHz. (Half Channel units), RF level 10 uV. 3. Adjust R16 for a 1.5 V p-p (530 mV RMS) signal on TP8.  4. Adjust the RF generator to .35 uV.  Adjust the squelch (located on the rear panel) so that the carrier detect LED is on, and so that it goes off when the RF level is below .25 uV.  11.2.3  Paging Modulation 1. Turn the unit off.  2. Generate a 1200 baud paging test signal by holding the 1 button down upon power up, then entering the password and pressing  6 1 2.  Specify an ON time of 30000 mS and an OFF time of 0 mS. 3. Adjust R34 for 2.5kHz (0 to peak) deviation. 4. Turn off the power to the unit.
«ProductName»      User Manual      7M303-1 Rev A2  Page 38 11.2.4  Voice Modulation & CTCSS 1. Turn the unit back on. 2. Key the transmitter using the F3 key.   Adjust R160 so the carrier is on frequency. 3. Adjust R60 (mic gain) for 1.5kHz deviation when speaking into the mic with a normal voice level from a distance of about 1 foot away. 4. Enable a 100 Hz CTCSS encoder on the transmit frequency. 5. Key the transmitter with the F3 key.  Adjust R32 for 500 Hz / 250 Hz deviation of the CTCSS tone. 6. Measure the transmitter's power level to verify that it is set to the desired level with the internal jumpers.
«ProductName»      User Manual      7M303-1 Rev A2  Page 39 12 Appendix A - Frequency Coordinators The following is a list of frequency coordination agencies.  Contact the agency which coordinates frequency assignments for the industry your business is in. 12.1  For frequencies designated with an "IW" in Section 90.35 of the Commission's rules:  UTC, The Telecommunications Association Attn: Frequency Coordination Department 1140 Connecticut Avenue, NW, Suite 1140 Washington, DC 20036 Phone: (202) 872-0030 Fax: (202) 331-7639 12.2  For frequencies designated with an "IP" in Section 90.35 of the Commission's rules:  Petroleum Frequency Coordinating Committee (PFCC) c/o Industrial Telecommunications Association, Inc. Attn: Frequency Coordination Department 1110 North Glebe Road, Suite 500 Arlington, Virginia 22201 Phone: (703) 528-5115 12.3  For frequencies designated with an "LR" in Section 90.35 of the Commission's rules:  Association of American Railroads Communications and Signal Division Attn: Chris Allman 50 F Street, NW Washington, DC 20001 Phone: (202) 639-2217 12.4  For all other frequencies, applicants may use any of the coordinators listed above or one of the following:  American Automobile Association (AAA) Attn: Gary M. Ruark 1000 AAA Drive, Mailspace 15 Heathrow, Florida 32746-5063 Phone: (407) 444-7786 Fax: (407) 444-7380  Personal Communications Industry Association (PCIA) Attn: Lori Baynton, Director Frequency Coordination Department 500 Montgomery Street, Suite 700 Alexandria, Virginia 22314-1561 Phone: 1-800-759-0300 FAX: (703) 739-0300  Central Station Alarm Association (CSAA) Attn: Robert Bitton, President P.O. Box 775 1565 Union Avenue Union, New Jersey 07083-0775 Phone: (908) 810-8822 Fax: (908) 810-8844  Forest Industries Telecommunications (FIT) Attn: Kenton E. Sturdevant 871 Country Club Road, Suite A Eugene, Oregon 97401 Phone: (541) 485-8441
«ProductName»      User Manual      7M303-1 Rev A2  Page 40 Manufacturers Radio Frequency Advisory Committee, Inc.(MRFAC) Attn: Frequency Coordination Department 1041 Sterling Road, #106 Herndon, Virginia 20171 Phone: (703) 318-9206 Fax: (703) 318-9209  Alliance of Motion Picture and Television Producers c/o Industrial Telecommunications Association, Inc. Attn: Spectrum Management Department 1110 North Glebe Road, Suite 500 Arlington, Virginia 22201 Phone: (703) 528-5115  American Trucking Association, Inc. (ATA) Attn: Kathy Garrett 2200 Mill Road Alexandria, Virginia 22314 Phone: (703) 838-1731  Newspaper Association of America (NAA) c/o Industrial Telecommunications Association, Inc. Attn: Frequency Coordination Department 1110 North Glebe Road, Suite 500 Arlington, Virginia 22201 Phone: (703) 528-5115 Industrial Telecommunications Association, Inc. Attn: Frequency Coordination Department 1110 North Glebe Road, Suite 500 Arlington, Virginia 22201 Phone: (703) 528-5115  International Taxicab and Livery Association (ITLA) Attn: Cecelia M. Hayes 3849 Farragut Avenue Kensington, Maryland 20895 Phone: (301) 946-5702  Telephone Maintenance Frequency Advisory Committee (TELFAC) c/o Industrial Telecommunications Association, Inc. Attn: Frequency Coordination Department 1110 North Glebe Road, Suite 500 Arlington, Virginia 22201 Phone: (703) 528-5115
«ProductName»      User Manual      7M303-1 Rev A2  Page 41 13 Appendix C - "Voice Prompt" Technical Details Voice prompt files are linked with the Peoplefinder II object code as the final part of the build process.  Voice prompts of any language or any speaker's voice may easily be incorporated.   Voice prompt files must be recorded in the following formats: 1. File Format:    .wav 2. Encoding Format:  PCM 3. Bits Per Sample:  8 4. Mode:    Mono 5. Amplitude:    Amplitude should be adjusted so voice peaks are about 75% full scale 6. Equalization:   Bandpass filtering of the audio from 300 Hz to 4 KHz prior to recording          is recommended  The following voice file names are used, with the given function and sample rates:  callend.wav  Call ended  22 KHz      callext.wav  Call extended  22 KHz    dialtone.wav  Dial tone  11 KHz  ent_err.wav  Entry error  22 KHz  msgdeliv.wav  Message delivered  22 KHz  null.wav  zero length null file    pagermsg.wav  Enter pager message  22 KHz  pagernum.wav  Enter pager number  22 KHz  phtimeo.wav  Phone timeout  22 KHz  sine300.wav  300 Hz sine wave  11 KHz  sine1k.wav  1 KHz sine wave  11 KHz  talknow.wav  Prompt user to talk   22 KHz  timeout.wav  Timeout error  22 KHz  The following additional files are used:  language.txt  Text file containing the name of the language

Navigation menu