Cadent MA14730 Cart transceiver User Manual EID 2 Optical Impression Device

Cadent Ltd. Cart transceiver EID 2 Optical Impression Device

Users Manual

           EID-2 Optical Impression Device Operation Manual        Optical Impression System for Computer Assisted Design and Manufacturing (510K exempt under 21 CFR 872.3661)  DIGITAL IMPRESSION DEVICE iTero Mobile Cart Publication SD08300-A Revision 1.10 April 18, 2007
EID-2 Optical Impression Device  Operation Manual 2  Publication SD08300-A  (Rev. 1.10)   COPYRIGHT Copyright © by Cadent. 1995-2007. All rights reserved. The hardware and software described in this document are supplied under a Sales and Services Agreement and may be used only in accordance with the terms of that agreement. The information contained in this document is subject to change without notice.  No part of this document may be reproduced, photocopied, stored in a retrieval system, or transmitted in any manner (electronic or mechanical) for any purpose other than the customer’s normal usage, without the prior written permission of Cadent.   TRADEMARKS Cadent, OrthoCAD, iTero, EID-1, EID-1 Optical Impression Device, EID2, EID-2 Optical Impression Device, OrthoCAD iQ, OrthoCAD Set-Up, OrthoCAD Bracket Placement and OrthoCAD Bracket Placement Video System are trademarks or registered trademarks of Cadent. Any other trademarks and registered trademarks appearing in this manual are the property of their respective owners.   CONTACT US Cadent, Inc. 640 Gotham Parkway Carlstadt NJ, 07072-2405   USA Phone:  (201) 842-0800 Fax:  (201) 842-0850 Email:   info@cadent.biz www.cadentitero.com
Operation Manual  EID-2 Optical Impression Device April 18, 2007  3   SYMBOLS  Caution!  -  Wherever this symbol appears on the device, it is recommended to refer to the instructions in this Operator’s Guide.  Applied part type B. Any component on which this symbol appears is electric isolation type B.  CLASS 1 LASER COMPLIANCE                                                 FCC COMPLIANCE  This device complies with Part 15 of FCC Rules, and operation is subject to the following two conditions: 1)  This device may not cause harmful interference. 2)  This device must accept any interference received, including interference that may cause undesired operation. FCC Warning Modifications to the device that are not expressly approved by the manufacturer may void your authority to operate the device under FCC Rules.  CSA COMPLIANCE  This device complies with the following CSA standard for Canada and the USA: UL Std No. 60601-1  –  Medical Electrical Equipment Part 1: General Requirements for Safety. Class 1 Laser Product This product complies with “21 CFR 1040.10” and “EN 60825-1”.
EID-2 Optical Impression Device  Operation Manual 4  Publication SD08300-A  (Rev. 1.10)   WARNINGS POWER   An internal battery backup unit will supply AC power to the system in the event of a power shortage. Therefore, power is present in the internal hardware components even when the system is unplugged from the wall. To ensure that power is removed from all components, follow these instructions:   Close all files and applications.   Press the front POWER switch to shutdown the system.   Press the MAIN POWER SHUT OFF switch on the back of the cart.   Unplug power cable from the wall socket.   To restore power, plug in the power cable and press the MAIN POWER SHUT OFF switch. The system will beep to indicate return of power.    According to Department of Transportation (DOT) regulations, the system must be shipped with internal battery leads disconnected. Please note that battery leads should be disconnected and reconnected by authorized Cadent technicians only.    Power is supplied to the system via an isolation transformer. WIRELESS LAN     The system comes equipped with a Wireless LAN unit. Using standard wired communications will violate the AC mains power isolation. SCANNER    Scanner emits red laser light (660 nm Class 1) as well as a multi-colored LED light. Normal usage of the scanner does not present any danger to the eye. However, the doctor should refrain from shining the light directly into the patient’s eyes.    The scanner cable should be handled with care. Avoid stepping on the scanner cable, rolling over the cable with the cart wheels, knotting, or over-twisting the scanner cable.   The scanner head contains fragile parts and should be handled with care. Before starting to work, be sure to read the instructions in Chapter 3 for disinfecting the scanner and replacing the disposable sleeve. GENERAL   Be careful not to block any of the air vents on the cart.    Refrain from opening any closed components. Except for the replacement of batteries in the mouse and foot pedal, all closed components should be serviced by authorized Cadent technicians only.   The system is intended for indoor usage only and should not be exposed to direct sunlight.   Due to its weight, the system should be lifted and loaded by two or more persons.
Operation Manual  EID-2 Optical Impression Device April 18, 2007  5  Table of Contents Chapter 1:  Introduction .......................................................................................................... 7 Overview ................................................................................................................................ 7 The Digital Crown Production Process ................................................................................... 7 About the iTero Service.......................................................................................................... 8 Using the iTero Software........................................................................................................ 8 Front Features........................................................................................................................ 9 Back Features.......................................................................................................................10 Chapter 2:  Operating Instructions ........................................................................................11 First Time Usage...................................................................................................................11 Booting System .....................................................................................................................11 Shutting Down System ..........................................................................................................11 Unplugging System for Short Intervals...................................................................................11 Automatic Shutdown..............................................................................................................12 Main Power Shut Off Before Shipping or Storage..................................................................12 Restoring Power After Shipping or Storage ...........................................................................12 Chapter 3:  Cleaning and Maintenance..................................................................................13 Foot Pedal Unit......................................................................................................................13 Disinfecting Scanner and Replacing Disposable Sleeve........................................................14 Cleaning Monitor ...................................................................................................................15 Appendix A:  Hardware Specifications..................................................................................16
EID-2 Optical Impression Device  Operation Manual 6  Publication SD08300-A  (Rev. 1.10)                This page is intentionally blank.
Operation Manual  EID-2 Optical Impression Device April 18, 2007  7 Chapter 1:  Introduction Overview The EID-2 functions as a digital impression system for scanning preparation teeth in the doctor’s office and uploading the digital files to Cadent for further processing and CNC crown production. This Operator’s Guide explains how to operate the system, and also describes the system’s hardware components and features.  Chapter 1: Introduction  Overview of the iTero digital crown production process. Chapter 2: Operating Instructions  Essential instructions for working with the EID-2 system. Chapter 3: Cleaning & Maintenance  Instructions for cleaning & maintenance of hardware components. Appendix A: Hardware Specifications  List of hardware specifications. The Digital Crown Production Process Below are listed the major steps involved in Cadent’s iTero Service for digital crown production. STEP 1:  Prepare Tooth and Perform Digital Scan Perform tooth preparation in conventional fashion. Then use the system to perform a high-resolution digital scan of the tooth. Upon completion of the scanning process, place a temporary crown on the patient tooth. STEP 2:  Upload Case to Cadent Upload the case to Cadent for processing based on your choice of materials and color. Cadent receives the case, performs crown design, and then sends the case to the lab technician for viewing and editing. STEP 3:  Lab Review The lab technician receives the case, performs any desired changes to crown design, and sends the updated case back to Cadent for production. (If necessary, one or more additional rounds of changes may be performed between Cadent and the lab before proceeding to step 4.) STEP 4:  Cadent Production Cadent receives the case from the technician, performs a final check, and then sends the case to CNC production. STEP 5:  Crown Shipped to Dentist for Fitting The finished crown is delivered by courier to the doctor's office. The temporary crown can then be removed from patient tooth and the permanent crown fastened in place.
EID-2 Optical Impression Device  Operation Manual 8  Publication SD08300-A  (Rev. 1.10) About the iTero Service Cadent’s iTero service has introduced to the dental industry a breakthrough technology in the field of digital crown production. The iTero technology makes it possible to perform an intra-oral digital scan in the office and to produce a precise crown based on the digitally acquired data. iTero provides important advantages over existing crown-production methods, including powder-free color scanning, greater crown-production accuracy, and immediate feedback during the scanning process. Refer to our website at www.cadentitero.com to learn more about how the iTero Service can save time and money for your practice. Using the iTero Software The EID-2 system works together with the iTero software applications.   The iTero OFFICE application is used for performing 3D color scans of the preparation teeth. The mouse and foot pedals can be used to respond to screen questions during the scanning process. For more information, press F1 to activate the iTero OFFICE help.  The iTero Case Manager works interactively with iTero OFFICE and handles file communications between the doctor’s office and the Cadent Center. For more information, press F1 to activate the iTero Case Manager help.  The Cadent support icon enables Cadent technical support to provide remote training and support.
Operation Manual  EID-2 Optical Impression Device April 18, 2007  9 Front Features Basic hardware features are shown below. See Chapter 2 for detailed operating instructions.   Flat LCD monitor can be swiveled freely in any direction. Optical scanner for capturing teeth images. Note that the scanner may be placed in scanner cradle in either direction (right-to-left or left-to-right). POWER switch for  boot and shutdown. Wireless foot pedal unit for responding to screen questions during scan process. Built-in keyboard Hook for holding scanner cable off the floor. The scanner cable should be handled with care. Avoid stepping on the cable, rolling over the cable with the cart wheels, knotting, or over-twisting the cable. Optical mouse Step down on levers to lock wheels. Lift levers to unlock.
EID-2 Optical Impression Device  Operation Manual 10  Publication SD08300-A  (Rev. 1.10) Back Features Basic hardware features are shown below. See Chapter 2 for detailed operating instructions.      Main AC Power Cable Air Vent (do not block) Air Vent (do not block)
Operation Manual  EID-2 Optical Impression Device April 18, 2007  11 Chapter 2:  Operating Instructions This chapter describes the essential operating instructions for booting or shutting down system. First Time Usage (1)  Plug the power cord into the wall socket. (2)  Press the “MAIN POWER SHUT OFF” button on the rear of the cart. System will beep to indicate presence of power. (3)  Leave the system plugged in for at least 24 hours. NOTE:  For first-time usage it is essential to boot the EID-2 system at least 24 hours prior to the first case scanning to ensure that the battery backup unit is fully charged. This 24-hour charge is also required in cases when the battery backup unit has been emptied (for example, if the system was unattended during a power out). Following the 24-hour charge period, it is recommended to leave the system running 24x7 in order to allow background file transfer with Cadent.  Booting System (1)  Press the front POWER switch. (2)  Green POWER LED goes on, PC boots, and MS Windows™ appears. NOTE:  If the green POWER LED does not go on, you may need to press the MAIN POWER SHUT OFF button on the back of the cart. The system will beep once to indicate power has been turned on. Shutting Down System   (1)  Close all files and applications (2)  Press the front POWER switch. (3)  MS Windows™ shuts down, PC turns off, and green POWER LED goes off. Unplugging System for Short Intervals Follow these instructions if you need to unplug the system for 10 minutes or less for relocation: (1)  Save current case in iTero software. (2)  Attach foot pedal to front of cart. (3)  Hang scanner cable on cart hook (see picture in Chapter 1). (4)  Unlock wheels by lifting wheel levers. (5)  Unplug power cable from the wall socket. The system will begin to beep. (6)  Move system to its new location and plug into wall socket. The system will stop beeping. (7)  Lock wheels by stepping down on wheel levers. (8)  Resume work where you left off.
EID-2 Optical Impression Device  Operation Manual 12  Publication SD08300-A  (Rev. 1.10) Automatic Shutdown When the cart is unplugged or a power outage occurs, a warning beep will begin. If the system is left unplugged for several minutes, warning messages will appear on the screen and will also be heard through the speakers. As the minutes pass, the status of the battery backup unit will be displayed on the screen. When the battery backup unit is nearly empty (after about 10 minutes), the system will automatically shut down. After an automatic shutdown, it may be necessary to press the front POWER switch once to “wake up” the system. Main Power Shut Off Before Shipping or Storage When you need to unplug the cart for an extended period of time, perform these steps: (1)  Close all files and applications. (2)  Press the front POWER switch to shut down system. (3)  Unplug power cable from the wall socket. (4)  Press the MAIN POWER SHUT OFF switch on the back of the cart to remove power from all internal components. Restoring Power After Shipping or Storage To restore power, press the MAIN POWER SHUT OFF switch once and the system will beep to indicate return of power. If the battery backup unit is low or empty (for example, if the system was unattended during a power out), a 24-hour recharge period is required to restore full capacity.
Operation Manual  EID-2 Optical Impression Device April 18, 2007  13 Chapter 3:  Cleaning and Maintenance This chapter describes how to clean and maintain the various hardware components. Foot Pedal Unit USING THE PEDALS The foot pedal unit contains two pedals for responding to screen questions during scanning. The colors of the two foot pedals match the Pedals dialog in the iTero OFFICE application (red on left, green on right). CHECKING BATTERY   Pressing either foot pedal turns on the green LED. The battery needs to be replaced if any of the following events occur:   Pressing a foot pedal causes the LED to blink (or the LED doesn’t light up at all).   Pressing a foot pedal causes no response within the iTero software.   A warning appears requesting that the battery be replaced.           REPLACING BATTERY To change the battery, follow the instructions below.                        LED
EID-2 Optical Impression Device  Operation Manual 14  Publication SD08300-A  (Rev. 1.10) Disinfecting Scanner and Replacing Disposable Sleeve To avoid cross contamination, it is essential that after each patient you disinfect the scanner and replace the disposable plastic sleeve. First use disinfectant wipes to clean the scanner arm, scanner cradle, keyboard and mouse. Then proceed with the steps below to replace the sleeve.    STEP 1 Press firmly on both sides of the disposable sleeve to release it.  STEP 2 Pull the disposable sleeve slowly off the scanner arm and discard.  STEP 3 As you remove the disposable sleeve, a protective metal cover is pulled over the optical surface.  WARNING !!!! Never touch the optical surface directly with your fingers, as contact may cause damage.  STEP 4 Gently slide on new sleeve by aligning metal peg to fit directly into the slot on side of sleeve.  STEP 5 Continue to slide the sleeve slowly onto the scanner arm until it clicks into place.
Operation Manual  EID-2 Optical Impression Device April 18, 2007  15 Cleaning Monitor (1)  Shut down the system using the front POWER switch to ensure that no power is being supplied to the monitor. (2)  Lightly dampen a clean white cotton cloth with water and wipe monitor clean. (3)  Dry the monitor immediately using a clean white cotton cloth. (4)  If further cleaning is necessary, use a clean cloth to wipe off the monitor with a small amount of alcohol.    Do not use liquid cleaners, chemicals or aerosol sprays to clean monitor.   Do not use abrasive cleaning materials such as newspaper or plastics to clean monitor.
EID-2 Optical Impression Device  Operation Manual 16  Publication SD08300-A  (Rev. 1.10) Appendix A:  Hardware Specifications  ITEM  DESCRIPTION Monitor  LCD 19” monitor meets FCC and safety approval (UL, CSA, TUV) and operates at 1280x1024 resolution. Handheld Scanner  Scanner emits red laser light (660 nm Class 1) as well as a multi-colored LED light. Battery Backup Unit  APC® Back-UPS® ES 725 Broadband Wireless LAN  DWL-G122™ Wireless USB Adapter produced by D-LINK®. The DWL-G122 provides 2.4 GHz communications using the 802.11g standard for wireless connectivity. Foot Pedal Battery  3V Lithium coin battery (type CR2450 or CR2477). Mouse  Optical wireless mouse. Mouse Battery  A screen message will appear when the mouse battery needs to be replaced. Use 1.5V alkaline LR6 battery (size AA). Operating Power  115V / 4.5A / 60Hz Operating Temperature 18°to 30°C 64.4° to 86°F Storage Temperature  0°to 50°C 32°to 122°F Humidity  30-90% Dimensions (including wheels but not including monitor) Height: 75.2 cm / 29.33 inches Width:  67.0 cm / 26.13 inches Depth: 40.0 cm / 15.60 inches Weight (including all components) 187.4 lbs  85 kg

Navigation menu