OverviewRobust Door Lock BodyKS & KC authentication give guaranted Quality and insured Product Satisfaction.Auto Lock/ Re Lock/Double Lock FunctionUser Friendly Function give Safety and easy usage.Dummy Number Functions give high level safety.Dummy Number & Real number combination give high level password.Multi-level volume control / mute optional FunctionUser can easily select 7level Volumne Control.Light Button indicate in the dark spaceYou can easy to use the device using light keypad buttons.Emergency Power Function (9V square battery)Emergency power working even if the batteries run out completely.Anti high-voltage / anti fireproof / anti-hacking systemIt is very safe for using anti high-voltage and anti-hacking system. Alsoif the temperature is higher than certain temperature, the door will beopen automatically with warning sounds under the fire.Digital Door Lock COMMAXMulti-registrations for pin-number & electronic keyIt is easy to register the pin-number(up to 4) and you can also register the electronic key(up to 30 ea).it available to Traffice card/credit Card,too.Metalic Diecasting DesignMetal body is durable to fire and shock from outer side hazardand damage.Safety CautionsDon’t install, repair ordisassemble the devicerandomly.Don’t push or insertthe button with drill or pin.Do not insert the batteries reversely.it will be cause some burst or leakage from batteries .When you clean thedevice, please use the dry towel.Change the pin-numberregularly for the safety.Don’t put water into the device.Do not use any otherpurpose for Door lock.when change battery, please use allnew alkaline battery.Don't heavy damage on door lock.This device is suitable for home safety level, other condition will not be guarante quality.Please read operationmanual Carefully.User Manualwww.commax.comDDL 영문 사용설명서.indd   2 2016. 5. 2.   오후 3:43
OverviewRobust Door Lock BodyKS & KC authentication give guaranted Quality and insured Product Satisfaction.Auto Lock/ Re Lock/Double Lock FunctionUser Friendly Function give Safety and easy usage.Dummy Number Functions give high level safety.Dummy Number & Real number combination give high level password.Multi-level volume control / mute optional FunctionUser can easily select 7level Volumne Control.Light Button indicate in the dark spaceYou can easy to use the device using light keypad buttons.Emergency Power Function (9V square battery)Emergency power working even if the batteries run out completely.Anti high-voltage / anti fireproof / anti-hacking systemIt is very safe for using anti high-voltage and anti-hacking system. Alsoif the temperature is higher than certain temperature, the door will beopen automatically with warning sounds under the fire.Digital Door Lock COMMAXMulti-registrations for pin-number & electronic keyIt is easy to register the pin-number(up to 4) and you can also register the electronic key(up to 30 ea).it available to Traffice card/credit Card,too.Metalic Diecasting DesignMetal body is durable to fire and shock from outer side hazardand damage.Safety CautionsDon’t install, repair ordisassemble the devicerandomly.Don’t push or insertthe button with drill or pin.Do not insert the batteries reversely.it will be cause some burst or leakage from batteries .When you clean thedevice, please use the dry towel.Change the pin-numberregularly for the safety.Don’t put water into the device.Do not use any otherpurpose for Door lock.when change battery, please use allnew alkaline battery.Don't heavy damage on door lock.This device is suitable for home safety level, other condition will not be guarante quality.Please read operationmanual Carefully.User Manualwww.commax.comDDL 영문 사용설명서.indd   3 2016. 5. 2.   오후 3:43
CONTENTSSpecificationParts NmaeHow to useEasy Function(option)Emergency AlarmFunctionBreakdown Cause and SolutionConsumer Protection RulesProduct WarrantySetting Pin NumberSetting Smart KeySetting BLE(Smartphone)Delete setting SmartkeyDelete setting BLEOpen the gate(Keypad)Lock the gate(Outside)Open the gate(Inside)Lock the gate(inside)Force Lock StatusAutolock SettingManual SettingSound Pause FunctionVolume Control FunctionDual Authentication &Registration on/offBuilt in Remocon SettingHeat WarningIntruder AlarmWarning Mischef and 1min stop functionDeadbolt(mortise) Error AlarmBattery Replacement WarningEmergency PowerEmergency Key(key type)Digital Door Lock COMMAXSpecificationsProduct StandardRF StandardFeaturesItemRFIDWireless DevicesOutside BodyBattery 4pcs Warning Sticker Screw Hole Paper Smartkey 2pcs Outdoor shaftEmergency 2keys(key type only)Inside Body Mortise Striker ScrewsUser manual(Warranty)Frequency13.56Mhz447.275MhzChannel1ch1chModulationASK Under 93.5dBuV/m@10mUnder 10mWFSKAntenna power (field strength)Division FeaturesInstall Condition Normal Fire Door Door thickness 40mm ~ 50mmUsage and Pre installation4~12 digit number combination(Up to 4 pin number)Up to 30 keysOptionOptionLR6 1.5V AA Size Alkaline Battery, 4 pcsAlkaline battery(Optional)Al, Zn, ABSAl, Zn, ABS72Ⳅ± 5Ⳅ (Lab Conditions)62Ⳅ ± 5Ⳅ (Normal Conditions)Pin NumberSmart keySmarphoneRemoconDC 6VDC 9VTemperature SensorExternal EnclosureInternal EnclosureFireproof type, Temperature sensor type, Key type, Master key door lock(D-NF-T-K-M)Access MethodsRated VoltageEmergency PowerProduct TypeTemperature AlarmMaterialwww.commax.comDDL 영문 사용설명서.indd   4 2016. 5. 2.   오후 3:43
Dual Authentication &Registration on/offWarning Mischef and 1min stop functionSpecificationsProduct StandardRF StandardFeaturesItemRFIDWireless DevicesOutside BodyBattery 4pcs Screw Hole Paper Smartkey 2pcs Outdoor shaftInside Body Mortise Striker ScrewsUser manual(Warranty)Frequency13.56Mhz447.275MhzChannel1ch1chModulationASK Under 93.5dBuV/m@10mUnder 10mWFSKAntenna power (field strength)Division FeaturesInstall Condition Normal Fire Door Door thickness 40mm ~ 50mmUsage and Pre installation4~12 digit number combination(Up to 4 pin number)Up to 30 keysOptionOptionLR6 1.5V AA Size Alkaline Battery, 4 pcsAlkaline battery(Optional)Al, Zn, ABSAl, Zn, ABS72 ± 5  (Lab Conditions)62  ± 5  (Normal Conditions)Pin NumberSmart keySmarphoneRemoconDC 6VDC 9VTemperature SensorExternal EnclosureInternal EnclosureFireproof type, Temperature sensor type, Key type, Master key door lock(D-NF-T-K-M)Access MethodsRated VoltageEmergency PowerProduct TypeTemperature AlarmMaterialwww.commax.comDDL 영문 사용설명서.indd   5 2016. 5. 2.   오후 3:43
Parts NameOutside Body Name & Function9V Emergency Battery(Sold Seperately)No NameKey Buttons Register or change the pin number.Open the door with registered pin number.Smartkey access point for open gate. By Contracting smartkeyopen the door or register smart key.When battery fully discharged, contact 9V battery and power on emergency power working.Open/register the electronic key.handle can open or close the door.Battery AlarmOutside HandleSmartkey Access PointEmergency PowerSupply TerminalFeaturesDigital Door Lock COMMAXNoDDL 영문 사용설명서.indd   6 2016. 5. 2.   오후 3:44
Parts NameOutside Body Name & Function9V Emergency Battery(Sold Seperately)No NameKey Buttons Register or change the pin number.Open the door with registered pin number.Smartkey access point for open gate. By Contracting smartkeyopen the door or register smart key.When battery fully discharged, contact 9V battery and power on emergency power working.Open/register the electronic key.Key Type onlyhandle can open or close the door.Battery AlarmEmergency Key holeOutside HandleSmartkey Access PointEmergency PowerSupply TerminalFeaturesDigital Door Lock COMMAXUsageInside Body Name & FunctionNo NameBattery CoverCover for battery and buttons for registration of pin number & electronic key.Receiver (CDL-447RM, option)Use registration or change the pin number or electronic keyLock or close the door for installing side of door.Lock the door to door frame.Prevent to shake the door.Check for Door open or Close.Battery for main powerLock the door under manual modeOpen or close the door from inside.Link PackRegister ButtonMortiseDead BoltsWrench BoltsSub Wrench BoltsAlkaline AA BatteryInner HandleManual Lock ButtonFeatureswww.commax.comDDL 영문 사용설명서.indd   7 2016. 5. 2.   오후 3:44
Add the other pin-number, you repeat       ,      until turn off the lightson keypad.(Pin number can be registered up to 4 pin numbers.The registration will be canceled when you do not push any numbers for10 seconds after push the registration button. If you register new pinnumbers,old one will be deleted automatically.How to useSetting the Pin-numberOpen the inside [battery cover],pushthe[Register]Button and hear "Beep" sound shortly.Check outside light on [Keypad]push the button NO      .Set the pin number 4 to 12 digits.Push the [         ] buttonmake "Beep" Sound and succeed registrationOne more push the [         ] buttonand completed registration.Please set the pin number while you open the door.CautionOutsideOutsideOutsideNoteCautionDigital Door Lock COMMAXCautionSetting Smart KeyNewly registered smart key or re-registred, please registerat a same time. other card not possible except provided card.CautionOpen the battery cover,Push the registration button oncethen you can hear “Beep” sound.[Smart key]close up on [smart key input]when succeed registration, sound beepingPush the [Register]button,it completed Registration.Check outside light on [Keypad]     push the      on the Keypad,    direction DimmingOutsideOutsideInsideNote if you want to add smartkey, it available max 30keys. if you want more add upsmartkey please repeat no      process before turn off [Keypad]light.it canceled [Register]button if smartkey not attach smartkey input.if new smartkey register (Process      ,      ,      ,      ), previous register smart keywill be automatically deleted.www.commax.comUsageDDL 영문 사용설명서.indd   8 2016. 5. 2.   오후 3:44
Add the other pin-number, you repeat       ,      until turn off the lightson keypad.(Pin number can be registered up to 4 pin numbers.The registration will be canceled when you do not push any numbers for10 seconds after push the registration button. If you register new pinnumbers,old one will be deleted automatically.How to useSetting the Pin-numberOpen the inside [battery cover],pushthe[Register]Button and hear "Beep" sound shortly.Check outside light on [Keypad]push the button NO      .Set the pin number 4 to 12 digits.Push the [         ] buttonmake "Beep" Sound and succeed registrationOne more push the [         ] buttonand completed registration.Please set the pin number while you open the door.CautionOutsideOutsideOutsideNoteCautionDigital Door Lock COMMAXCautionSetting Smart KeyNewly registered smart key or re-registred, please registerat a same time. other card not possible except provided card.CautionOpen the battery cover,Push the registration button oncethen you can hear “Beep” sound.[Smart key]close up on [smart key input]when succeed registration, sound beepingPush the [Register]button,it completed Registration.Check outside light on [Keypad]     push the      on the Keypad,    direction DimmingOutsideOutsideInsideNote if you want to add smartkey, it available max 30keys. if you want more add upsmartkey please repeat no      process before turn off [Keypad]light.it canceled [Register]button if smartkey not attach smartkey input.if new smartkey register (Process      ,      ,      ,      ), previous register smart keywill be automatically deleted.www.commax.comUsageDDL 영문 사용설명서.indd   9 2016. 5. 2.   오후 3:44
Delete setting SmartkeyOpen the inside [Battery cover]push the[Register] Buttonand hear "beep" sound shortly.Push the [          ]during 5sec.it makes 'Beep"sound and deleteentire smartkey information.Chekc outside [Keypad] lightning on,Push the      Button, light on [          ]Button.5secUsageOutsideOutsidewww.commax.comDDL 영문 사용설명서.indd   10 2016. 5. 2.   오후 3:44
Delete setting SmartkeyOpen the inside [Battery cover]push the[Register] Buttonand hear "beep" sound shortly.Push the [          ]during 5sec.it makes 'Beep"sound and deleteentire smartkey information.Chekc outside [Keypad] lightning on,Push the      Button, light on [          ]Button.5secUsageOutsideOutsidewww.commax.comDDL 영문 사용설명서.indd   11 2016. 5. 2.   오후 3:44
Check outside light on [Keypad] push the button Nopress No      Button and LED Light on [         ]Press button 5sec [          ]Beep sound and delete whole BLE Regitstered key.Dummy number function will be add up head or tail to original password.    dummy No+original password       original password+dummy No(for preventing from other person cheating password)How to useDelete Setting BLEMethod1open the gate (Keypad)(CDL - 3PBR Model Case)Open the inside [Battery cover] pushthe [Register] Button and hear"Beep" sound shortly.Key pad openningTouch [Keypad],input [Password].Push the [            ]button and bellingbeep sound Door will be released.OutSideOutSide5secNoteDigital Door Lock COMMAXOpen the gate (Smart Key)UsageMethod 2Method 3Method 4Smartkey OpeningBLE(smartphone)Opening (CDL - 3PBR Model type)Registered [Smart Key]close to [Smart key] access point.Beep sound and open the Gate.Shake on [BLE (Smartphone)]on the access point.Remocon opening (option)Push the [OP/CL]button on the Remocon and open the gate.Beep sound and open the oate.Note In case of Credit card/Traffic card, touch key first and then light on[Keypad] and close to access point, it will be open the gate.www.commax.comDDL 영문 사용설명서.indd   12 2016. 5. 2.   오후 3:44
Check outside light on [Keypad] push the button Nopress No      Button and LED Light on [         ]Press button 5sec [          ]Beep sound and delete whole BLE Regitstered key.Dummy number function will be add up head or tail to original password.    dummy No+original password       original password+dummy No(for preventing from other person cheating password)How to useDelete Setting BLEMethod1open the gate (Keypad)(CDL - 3PBR Model Case)Open the inside [Battery cover] pushthe [Register] Button and hear"Beep" sound shortly.Key pad openningTouch [Keypad],input [Password].Push the [            ]button and bellingbeep sound Door will be released.OutSideOutSide5secNoteDigital Door Lock COMMAXOpen the gate (Smart Key)UsageMethod 2Method 3Method 4Smartkey OpeningBLE(smartphone)Opening (CDL - 3PBR Model type)Registered [Smart Key]close to [Smart key] access point.Beep sound and open the Gate.Shake on [BLE (Smartphone)]on the access point.Remocon opening (option)Push the [OP/CL]button on the Remocon and open the gate.Beep sound and open the oate.Note In case of Credit card/Traffic card, touch key first and then light on[Keypad] and close to access point, it will be open the gate.www.commax.comDDL 영문 사용설명서.indd   13 2016. 5. 2.   오후 3:44
How to useLock the gate (Outside)Open the gateMethod 1Method 1Method 2Auto LockingManual LockingPull the inside handleClosing the door and lock the doorafter 2second automatically.Touch the [Keypad], door will be lock.Just pull the handle,open the door easily.2secCautio nDo not use or install outside dragging type door.Digital Door Lock COMMAXMethod Method ReleasingForce Locking - Impossible by password, Smarphone, Smartkey from outside.Push the handle from inside, Force Locking will bereleased.Enther Lock StatusPush the [Double Lock] 3sec, beep soudingand enter Force Locking.MethodDDL 영문 사용설명서.indd   14 2016. 5. 2.   오후 3:44
UsageLock the gate (inside)Force Lock StatusMethod 1Method 2ReleasingAuto LockingClosing the door and lock the door after2 second automatically.Manual LockingForce Locking - Impossible by password, Smarphone, Smartkey from outside.Pull the handle from inside, Force Locking will bereleased.Enther Lock StatusPush the [Double Lock] 3sec, beep soudingand enter Force Locking.Push the inside[double lock] button,door will be manual locking.2sec3secNote Manual locking push the [double locking],gone to Locking status "beep"noise and entered Double locking status.www.commax.comMethodDDL 영문 사용설명서.indd   15 2016. 5. 2.   오후 3:44
Easy Function (option)Autolock SettingManual SettingThis function is Autolock settingThis function is Manual Lock settingOpen the door statusOpen the door statusPlease checkbeside mortisePop up.Please checkbeside mortisePop up.Touch the ouside[Keypad]Input passwordand push the[        ]button twice.Push the No[7] andcomplete Beepingand settingAutolocking.Touch the ouside[Keypad]Push the No[4] andcomplete Beepingand settingAutolocking.Input passwordand push the[        ]button twice.Autolock SettingManual Lock settingNoteFactory default is Auto lock setting.Digital Door Lock COMMAXpush the keypad of No[3] button volume up.                                 No[6] button volume down.when enter Stop volume function keypad BlinkSound Pause FunctionVolume Control FunctionThis function for 1time mute for preventing beeping.This function for Volume Level control function. (closing door status available)Touch outside [keypad]and push the [         ]Volume coltrol by 7 level.Password: input password and push the [        ]buttonCard: Card access the sensorBLE(Smartphone) : BLE access and open the gate.MethodMethodUsageNoteNoteThis function is just 1time, next time back again beep sound statusPlease checkbeside mortisePop up.Touch the ouside[Keypad]Push the No[3] orNo[6] button onthe [Keypad]Input passwordand push the [       ]button twice.www.commax.comwww.commax.comDDL 영문 사용설명서.indd   16 2016. 5. 2.   오후 3:44
Easy Function (option)Autolock SettingManual SettingThis function is Autolock settingThis function is Manual Lock settingOpen the door statusOpen the door statusPlease checkbeside mortisePop up.Please checkbeside mortisePop up.Touch the ouside[Keypad]Input passwordand push the[        ]button twice.Push the No[7] andcomplete Beepingand settingAutolocking.Touch the ouside[Keypad]Push the No[4] andcomplete Beepingand settingAutolocking.Input passwordand push the[        ]button twice.Autolock SettingManual Lock settingNoteFactory default is Auto lock setting.Digital Door Lock COMMAXpush the keypad of No[3] button volume up.                                 No[6] button volume down.when enter Stop volume function keypad BlinkSound Pause FunctionVolume Control FunctionThis function for 1time mute for preventing beeping.This function for Volume Level control function. (closing door status available)Touch outside [keypad]and push the [         ]Volume coltrol by 7 level.Password: input password and push the [        ]buttonCard: Card access the sensorBLE(Smartphone) : BLE access and open the gate.MethodMethodUsageNoteNoteThis function is just 1time, next time back again beep sound statusPlease checkbeside mortisePop up.Touch the ouside[Keypad]Push the No[3] orNo[6] button onthe [Keypad]Input passwordand push the [       ]button twice.www.commax.comwww.commax.comDDL 영문 사용설명서.indd   17 2016. 5. 2.   오후 3:44
Easy Function (option)Autolock SettingThis function is Dual authentication and registration on / offDual Authentication on/offRegistration on / offTouch the ouside[Keypad]Touch the ouside[Keypad]Input password Push the No[8] andcomplete Beepingand settingAutolocking.Push the[        ]button twice.Input password Push the[        ]button twice.Push the No[1] andcomplete Beepingand settingAutolocking.Note Dual authenfication mode can open Smart key and password together. Regstration mode can open previouse password input. each process will be off by same process (sound : bee~leek) Factory default is Dual Authentication and Registrtion off status.Digital Door Lock COMMAXUsageBuilt in Remocon SettingThis function is Built in remocon setting. (for only Built remocon included model)Remocon onRemocon offOpen the inside[Battery cover] pushthe[Register] Buttonand hear "Beep"sound shortly.Open the inside[Battery cover] pushthe[Register] Buttonand hear "Beep"sound shortly.Push the No[8] button Push the [#] button5sec, "beep"soundand remocon will beoff status.Push the No[3]button andindicate Antennaicon LED.Push the [OP/CL]button on theRemocon.Push the inside[Register]button,it completedRemocon settingNoteCautionAdd more remocon, please repeat no 2 process before light blink off(max 5 remocon available)Push the [Register]button and not link with Remocon, it will be canceledremocon setting.New remocon Setting before Remocon will be deleted.www.commax.comDDL 영문 사용설명서.indd   18 2016. 5. 2.   오후 3:44
Easy Function (option)Autolock SettingThis function is Dual authentication and registration on / offDual Authentication on/offRegistration on / offTouch the ouside[Keypad]Touch the ouside[Keypad]Input password Push the No[8] andcomplete Beepingand settingAutolocking.Push the[        ]button twice.Input password Push the[        ]button twice.Push the No[1] andcomplete Beepingand settingAutolocking.Note Dual authenfication mode can open Smart key and password together. Regstration mode can open previouse password input. each process will be off by same process (sound : bee~leek) Factory default is Dual Authentication and Registrtion off status.Digital Door Lock COMMAXUsageBuilt in Remocon SettingThis function is Built in remocon setting. (for only Built remocon included model)Remocon onRemocon offOpen the inside[Battery cover] pushthe[Register] Buttonand hear "Beep"sound shortly.Open the inside[Battery cover] pushthe[Register] Buttonand hear "Beep"sound shortly.Push the No[8] button Push the [#] button5sec, "beep"soundand remocon will beoff status.Push the No[3]button andindicate Antennaicon LED.Push the [OP/CL]button on theRemocon.Push the inside[Register]button,it completedRemocon settingNoteCautionAdd more remocon, please repeat no 2 process before light blink off(max 5 remocon available)Push the [Register]button and not link with Remocon, it will be canceledremocon setting.New remocon Setting before Remocon will be deleted.www.commax.comDDL 영문 사용설명서.indd   19 2016. 5. 2.   오후 3:44
Emergency Alarm FunctionHeat WarningWhen a fire is detected, a high temperature ofabout suspected (62Ⳅ ± 5Ⳅ), automaticallyreleases the locked state with strong beeps forsafety.Heat WarningWarning mischief and 1 minute stop functionAbnormally in the door is locked(For example: forcely open the gate) occurs when the door open condition is detectedBeep noise makes 80 db (db) beeper.If input not registered [password] or [Smart Key repeatedly enteredfive times l stop operating 1 minutes with alarm.Remove battery or input [password] or attach [smart key] , it will be turn off warning and alarm.When high temperrature status, it will be not turn off status. please cool down temperature.In case of inside body recieve sunlight, it will be warning and alarm.so, dual authentication will be turn off automaticallyTurn off alarmMistake input5 times??Turn off heat warning & Intruder alarmCautionDigital Door Lock COMMAXUsageDeadbolt(mortise)error alarmBattery Replacement WarningOpened or locked, when the deadbolt (square clamp) of the indoorunit body is normally taken out, ordo not enter "beep, beep beep,beep" warning sound occurs threetimes.Battery icon light on the Keypad or make sound "bleek bleekbleek", please change battery. all battery change required.Deadbolt(Mortise) “BBBB”“Bleek  Bleek  Bleek.”CautionCautionCautionIf sound alarm countinuos or not workging properly. it required reallocation door lockposition, please contact installer or door lock professional company.Do not use mixed with used battery and New battery , Please change all batteryto new ones.Wireless module use battery consumption, Battery recycle will be moreshorthen.www.commax.comDDL 영문 사용설명서.indd   20 2016. 5. 2.   오후 3:44
Emergency Alarm FunctionHeat WarningWhen a fire is detected, a high temperature ofabout suspected (62Ⳅ ± 5Ⳅ), automaticallyreleases the locked state with strong beeps forsafety.Heat WarningWarning mischief and 1 minute stop functionAbnormally in the door is locked(For example: forcely open the gate) occurs when the door open condition is detectedBeep noise makes 80 db (db) beeper.If input not registered [password] or [Smart Key repeatedly enteredfive times l stop operating 1 minutes with alarm.Remove battery or input [password] or attach [smart key] , it will be turn off warning and alarm.When high temperrature status, it will be not turn off status. please cool down temperature.In case of inside body recieve sunlight, it will be warning and alarm.so, dual authentication will be turn off automaticallyTurn off alarmMistake input5 times??Turn off heat warning & Intruder alarmCautionDigital Door Lock COMMAXUsageDeadbolt(mortise)error alarmBattery Replacement WarningOpened or locked, when the deadbolt (square clamp) of the indoorunit body is normally taken out, ordo not enter "beep, beep beep,beep" warning sound occurs threetimes.Battery icon light on the Keypad or make sound "bleek bleekbleek", please change battery. all battery change required.Deadbolt(Mortise) “BBBB”“Bleek  Bleek  Bleek.”CautionCautionCautionIf sound alarm countinuos or not workging properly. it required reallocation door lockposition, please contact installer or door lock professional company.Do not use mixed with used battery and New battery , Please change all batteryto new ones.Wireless module use battery consumption, Battery recycle will be moreshorthen.www.commax.comDDL 영문 사용설명서.indd   21 2016. 5. 2.   오후 3:44
Emergency Alarm FunctionEmergency PowerNoteBatteyr gone, impossible open the door status.Buy9V Battery.9v batteryattachEmergencyPower supplyterminal.Press the[        ]button.Input[Password].Push the [      ]Button againand it beep andunlock.Digital Door Lock COMMAXIf the product does not operate normally, check the following check point first.No PowerNo Change PasswordPassword / Smart keyauthentication successbut no open the doorkeep going alarm“Beleek x3 warning sound.No enterAuto LockingNo open the doorthough push the[        ]buttonDDL 영문 사용설명서.indd   22 2016. 5. 2.   오후 3:44
Emergency Alarm FunctionEmergency PowerEmergency Key (Key Type)NoteNoteBatteyr gone, impossible open the door status.Not open the door properly status.Buy9V Battery.Check handleemergency keyhole outside.Emergency Keyinput Key hole and turn left and right.‘Tak’click soundand turn tocenter,Deadbolt willbe unlock.Drag the handleand door will beopen.Take Emgergencykey this kind ofupper direction.9v batteryattachEmergencyPower supplyterminal.Press the[        ]button.Input[Password].Push the [      ]Button againand it beep andunlock.Digital Door Lock COMMAXBreak down cause and solutionIf the product does not operate normally, check the following check point first.UsageProblem Solution RemarksNo PowerNo Change PasswordPassword / Smart keyauthentication successbut no open the doorkeep going alarm“Beleek x3 ”warning sound.No enterAuto LockingNo open the doorthough push the[        ]button- Please check battery status bad or gone power and   check battery input direction- please change new 4 alkaline Battery.- Please input password short “Beep”sound one by one.- Again password register / repeat input.8 Page8 Page22 Page21 Page16 Page- Please try 9V emergency power(square type)- Lock can may broken. please contact installer.- Please reset automode.- Sound occurs the batteries discharge and does   not work. please change all new battery- Beep indicating the battery replaced.  if you heard this alarm, please replace all new  4pcs battery.- please check passwor input correctly- When input password, keypad light off, it will be not   change password , presss the [        ]button and check   keypad light on, input password again.   (if didnot input password within 7sec, it will be canceled.)www.commax.comDDL 영문 사용설명서.indd   23 2016. 5. 2.   오후 3:44
Consumer Protection Rules• COMMAX conducted a guarantee of the product as shown below each item,depending on the consumer compensation regulations.• Please install the product can not be installed by a professional installer orauthorized installer to install receive A / S if faulty.If the product fails within the first year after purchase (the warranty period), you get the free service only.Functional defects in normal use occurred in 10 days ProductExchangeProductExchangeProductExchangeProductExchangeFunctional defects in normal use occurred in 1monthServiceable same fail 3times again Repair free Repair chargeRepair chargeDepreciation andexchangeDepreciation andexchangeProduct exchangesame file 4times againWhen repair parts for repair but impossible(within the parts holding period))When repair parts are not impossible torepair (parts within the retention period)• If it is not subject to failure, it will be service charge. Please readthe instruction manual.• Installation issue on non-malfunction.• Force damage on the device for lost password.• User Handling of abuse or inappropriate repair, modification and trouble occurs.• Non official installer or non professional person installed and make trouble.• Drop or make damage by cause of fault or error.• If any trouble occurs due to natural disasters (lightning, fire, salt damage, flood, etc.)• If the end-life of the consumable parts (batteries, etc.)• normal case consumer receive within 15month(including distribution period)No Serviceable1. For non-failure3. etc2. If the consumerfails to negligenceIf the warranty period will be shortened half period by commerical usage.Emergency PowerPaid ServiceConsumer Damage TypeCompensationwithin Warranty after warrantyDigital Door Lock COMMAXProduct WarrantyUsageProduct NameProduct NumberPurchase (installed) DateInstaller CompanyTelephoneAddressInstaller's Name20        year        month         daysCustomer's NameTelephoneAddressPlease keep this document for full service must present this warranty.1) Warranty for this product is the warranty benefits to the contents listed in the warranty.2) The warranty period is calculated from the date of purchase, so please obtain     a base purchase date.www.commax.comDDL 영문 사용설명서.indd   24 2016. 5. 2.   오후 3:44
Consumer Protection Rules• COMMAX conducted a guarantee of the product as shown below each item,  depending on the consumer compensation regulations.• Please install the product can not be installed by a professional installer or   authorized installer to install receive A / S if faulty.If the product fails within the first year after purchase (the warranty period), you get the free service only.Functional defects in normal use occurred in 10 days ProductExchangeProductExchangeProductExchangeProductExchangeFunctional defects in normal use occurred in 1monthServiceable same fail 3times again Repair free Repair chargeRepair chargeDepreciation andexchangeDepreciation andexchangeProduct exchangesame file 4times againWhen repair parts for repair but impossible(within the parts holding period))When repair parts are not impossible torepair (parts within the retention period)• If it is not subject to failure, it will be service charge. Please read  the instruction manual.• Installation issue on non-malfunction.• Force damage on the device for lost password.• User Handling of abuse or inappropriate repair, modification    and trouble occurs.• Non official installer or non professional person installed and make trouble.• Drop or make damage by cause of fault or error.• If any trouble occurs due to natural disasters    (lightning, fire, salt damage, flood, etc.)• If the end-life of the consumable parts (batteries, etc.)• normal case consumer receive within 15month(including distribution period)No Serviceable1. For non-failure3. etc2. If the consumer    fails to negligenceIf the warranty period will be shortened half period by commerical usage.Emergency PowerPaid ServiceConsumer Damage TypeCompensationwithin Warranty after warrantyDigital Door Lock COMMAXProduct WarrantyUsageProduct NameProduct NumberPurchase (installed) DateInstaller CompanyTelephoneAddressInstaller's Name20        year        month         daysCustomer's NameTelephoneAddressPlease keep this document for full service must present this warranty.1) Warranty for this product is the warranty benefits to the contents listed in the warranty.2) The warranty period is calculated from the date of purchase, so please obtain a base purchase date.www.commax.comDDL 영문 사용설명서.indd   25 2016. 5. 2.   오후 3:44
MEMODigital Door Lock COMMAXwww.commax.comDDL 영문 사용설명서.indd   27 2016. 5. 2.   오후 3:44FCC Statement15.19:This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.15.21:Note: The grantee is not responsible for any changes or modifications not expressly approved bythe party responsible for compliance. Such modifications could void the user’s authority to operatethe equipment.15.105(b):Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver.- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.The manufacturer, importer, and distributor shall not be liable for damages including accidental andpersonal injury due to the improper use or operation of this product. The information in thisuser manual was written based on current product specifications. The manufacturer, iriver Limited,is adding new complementary features and will continue to apply new technologies in the future.Product specifications may be changed without prior notice.iriver is not responsible for data loss due to product use.DisclaimersThe transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.  This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.Exposure statement
MEMODigital Door Lock COMMAXMEMOwww.commax.comMEMODDL 영문 사용설명서.indd   26 2016. 5. 2.   오후 3:44
MEMODigital Door Lock COMMAXMEMOwww.commax.comMEMODDL 영문 사용설명서.indd   27 2016. 5. 2.   오후 3:44
DDL 영문 사용설명서.indd   28 2016. 5. 2.   오후 3:44

Navigation menu